Entry  Wed Feb 22 21:51:40 2017, Keerthi Jayamanna, , , SIS first beam is N1+1 
Chris confirmed the first SIS beam would be Na+1. Next Rb+1 and then Li+1
Entry  Wed Feb 22 21:46:27 2017, Keerthi Jayamanna, , , Elog is working now 
Elog is now functioning. We can start entering notes
Entry  Mon Sep 14 11:21:16 2015, Keerthi Jayamanna, Routine, General, 20Ne+2 beam saved 
20Ne+2 beam optics saved as 150914_1117_ios0iosfc6.snap
Entry  Thu May 21 09:15:48 2015, Brian Minato, , ,  
Service of MCIS.  Plasma chamber cleaned.  Repaired shorted, Right steering plate.  Added shields to help prevent coating of wires. 
Beam is off centre on first collimator of steering assembly.
Moved Ground electrode away from PE approximately 0.10".
Entry  Wed Apr 29 07:48:22 2015, Brian Minato, Other, Other, Repair- Water leak inside HV cage 
A water leak was reported inside the HV cage (FR#8079).  The cage was accessed to determine the source of the leak (WP#I2015-04-27-1).
The WMS cusp cooling line was leaking.  It was close to the MCIS cart (at ground) and had sparked through.  The hose was cut at the puncture
location and re-connected. to the fitting.  It was re-routed to be further away from the MCIS cart.
Entry  Mon Apr 20 08:09:03 2015, Brian Minato, Routine, General, OLIS Shutdown Update 
The OLIS 1 week shutdown has been completed (WP 2015-04-13-1).
General-
Y-Box insulators were inspected and look good.  Beamline optics were inspected.
Entry  Wed Dec 17 13:17:13 2014, Brian Minato, Other, Other, MCIS Update 
The MCIS was vented with nitrogen yesterday.  The Se oven was drawn back into the tuner.  It was removed with the tuner and blanked.
The standard quartz window was removed and replaced with a ceramic, test window supplied by CPI. (p/n VWU2054).  The system is currently pumping
down.
Entry  Tue Nov 25 12:23:28 2014, Keerthi Jayamanna, Routine, General, 76Se+13 tune saved 
141125_1159_OLIS_76Se+13.snap is saved in reference directory.
El=3480/4303V
MCIS:YCB1=110
Entry  Tue Nov 25 07:49:50 2014, Brian Minato, Other, General, MCIS and SIS Update 
MCIS-
the Se was loaded into the oven last friday (21st).  During the weekend the presence of 76Se +11 to +15 was verified.
NOTE- the oven p/s on the cart is broken.  An attempt was made to remove it on friday.  It may be possible to remove, if the rack it
Entry  Wed Nov 19 11:34:55 2014, Raymond Dube, Routine, General, OLIS Electrical diagram with 3 I.S. ISK4586D-rev2.pdf
I updated the electrical Diagram  for OLIS Faraday Cage with 3 Ion Source, ref: ISK4586D rev. 2
PS:  Make sure that you do not connect both Bias P/S on same Ion Source ... 
Entry  Tue Nov 18 08:56:23 2014, Brian Minato, Other, General, ALGA Update 
There has been no noticeable loss of communication to the ALGA 50watt amplifier.  As a test, the ethernet cable was removed for about a minute and
then reconnected.  The amplifer re-established communication without issue.  This test was done twice.
Now, the CPI ethernet cable has been returned to the CPI amplifier.  The original ALGA ethernet cable (blue) has been reconnected to the ALGA.
Entry  Thu Nov 13 16:34:29 2014, Brian Minato, Other, Other, MCIS Update 
The ethernet cable from the CPI TWT amplifier has been temporarily moved to the Alga 50W amplifier.  The Alga had been experiencing loss of communication. 
This has not been an issue with the CPI so this cable will be tried with the Alga.  A signal generator is not connected to the Alga.
Entry  Thu Nov 13 16:31:54 2014, Brian Minato, Other, Other, SIS 
A new SIS source has been installed.  The oven has been loaded with Sodium Hydrogen Carbonate (Alfa Aesar 10863) and Rubidium Nitrate.
Pictures are located in 2014-11-13 Source and PS Pics
Entry  Wed Nov 12 13:32:47 2014, Raymond Dube, Routine, General, New in-line resistors for IOS:PE ISK4583D-rev10.pdf
Today we replace the in-line resistors for the Plasma Electrode (PE) it was a 25 ohm 200W (2 x 50 Ohm 100W) with a 50 Ohm 200W (2 x 100 Ohm / 100W) also
added the inductance coil.
This is R5 on drawing: ISK4583D rev. 10
Entry  Thu Nov 6 08:37:52 2014, Brian Minato, Other, Other, OLIS Update 
MCIS-
the source is off.  It is under vacuum and in the HV cage.
SIS-
Entry  Sat Nov 1 13:31:17 2014, Keerthi Jayamanna, , , MCIS readyness for 76Se 
Supernanogan is running with oven no heat, without 76selenium. MCIS:IG1=3e-7Torr.
Tune saved as 141101_1318_76Se+11tune.snap
MCIS steering  X=330, Y=226, CCB1=500, MCISEL=4171/5157, PE=11.5/23, FC6=76nA(16O+7)
Entry  Fri Oct 31 20:39:56 2014, Brian Minato, Other, Other, OLIS Update 
MCIS-
the MWS Bias and PE have been moved on to the MCIS (the MCIS connections have been removed).
The plug in power to the HP Signal generator has been moved to a continuous source (Removed from the source controlled by the SSW).
Entry  Thu Oct 30 23:44:57 2014, Keerthi Jayamanna, Routine, General, OLIS Supernanogan mass scan 6 to 7.5 
A/q           FC6  (only current over 100pA)
6.0           1.85e-7
6.15         4.96e-10
Entry  Thu Oct 30 23:37:58 2014, Keerthi Jayamanna, Routine, General, Mass scan 4 to 6 
A/Q            FC6
4                1.1e-6
4.25          8e-10
Entry  Thu Oct 30 22:44:45 2014, Keerthi Jayamanna, Routine, General, Mass scan 3 to 4 
IOS mass scan if faulty. These is a manual scan from mass 3 to 4
Const22 = 0.04187  adjusted to mass = 4
A/q               FC6           X         
Entry  Thu Oct 30 22:09:02 2014, Keerthi Jayamanna, , , Suoernanogan steering 
IOS mass scan does not work.
A/Q            FC6                X         
Y          CCB1
Entry  Thu Oct 30 13:14:51 2014, Brian Minato, Other, Other, OLIS Update 
MCIS-
a new oven assembly was installed on the MCIS yesterday.  The cart has been installed in the cage and is connected.
The power is connected to the cart oven as is the MCIS bias.  it is currently on and being tested for Se
Entry  Tue Oct 28 13:30:47 2014, Brian Minato, Other, Other, MCIS Update 
MCIS-
the cleaning has been completed.  The oven assembly is removed and the gate valve closed.
The quartz tubes on the ground electrode have been installed with the larger diameter tube pushed as far downstream (toward the optics box) as
Entry  Mon Oct 27 15:13:18 2014, Brian Minato, , ,  
MCIS-
cleaning out source to remove potassium and calcium.
Areas cleaned with scotch-brite and then wiped with methanol:  plasma chamber, tuning chamber (ports opened for access), TP3 tube.  The
Entry  Fri Oct 24 10:50:20 2014, Brian Minato, Other, Other, OLIS Update 
The nitrogen bottle needs to be replaced.
 
MCIS-
Entry  Thu Oct 23 10:52:21 2014, Brian Minato, Routine, General, ALGA Amplifier 
The ALGA amplifier and its signal generator have been turned off at the request of Controls.  They have had communication issues and are looking
for any recent changes.
Entry  Wed Oct 22 07:58:32 2014, Brian Minato, Other, General, MCIS Work 
The remaining connections were done on the MCIS. 
A piece of 1/8" teflon was installed between the back of the sputtering tube/motor and the HV cage.
Ray confirmed the cart power supplies (heater and sputtering) Epics page readouts for Voltage and Current are okay.  The Heater p/s was left
Entry  Tue Oct 21 07:14:26 2014, Brian Minato, Other, General, OLIS Work 
MCIS-
the cart was moved into the HV cage.  The facilities will be connected and an oven will be tested for the upcoming Se experiment.
Will take measurements for installation of key interlocks on cart power supplies.
Entry  Tue Oct 14 08:31:53 2014, Brian Minato, Other, General, Water Flow Switch #3 
This entry was incorrectly added to the OLIS logbook.  it has been moved to the I3 logbook.
Entry  Fri Oct 10 14:02:56 2014, Raymond Dube, Routine, General, Test with new Alga, ALPA 50W RF AMP ALPA-RF_AMP-50W.pdf
We did a test yesterday with the new Alga Microwave RF AMP, model # ALPA 50 Watt, serial # 130684 to be used for the MCIS.  We used the RF Generator
from MISTIC and set the frequency to 13.80 Ghz, note that the RF Generator was/is  limited to 16DB maxiumum RF output.
The RF cable that we used was from the 200W RF AMP, it has a 20DB SMA attenuator at the Generator end, so we could only get about 25 Watts maximum
Entry  Tue Sep 16 11:55:28 2014, Raymond Dubé, Routine, General, MCIS info Cart-Power1.pdfSuperNanogan_Control-R1.pdfSupernanogan_Interlocks-R1.pdf
I found these files about the MCIS in Geoff folders in M:\ISIS\Geoff-110715\OLIS\SuperNanogan
Entry  Wed Aug 13 15:09:42 2014, Raymond Dubé, Routine, General, OLIS Attenuators #2 fixed, #1 gone! 
Today Probe group (Scott K.) installed the OLIS Attenuator, they fixed the vacuum leak on Attenuator #2,  Marco
M. asked them to remove Attenuator #1 because it is not needed and confusing for Ops;
 
Entry  Wed Aug 13 15:04:05 2014, Raymond Dubé, , , OLIS Bender Magnet PS (0-500 amps) 
Arthur and Derek had a look at the OLIS Bender Magnet P/S and found a problem with the Polarity Switch, it was set up
upside down, they fixed that.
Note: We do not need a Polarity Switch for OLIS may be we should remove or bypass it, at the moment when the PS
Entry  Wed Aug 13 15:00:27 2014, Raymond Dubé, Routine, General, OLIS Surface Source broken Ionizer Coil ISK4386D-rev5.pdfISK4583D-rev7.pdfISK4584D-rev1.pdfPE-R5-FAN_ON.jpg
We spent most of the day looking at OLIS to find out why the "Ionizer Coil" keeps breaking down, we found
the following:
1.  The FAN to cool R5 (ref: ISK4583D rev.7) a 25 Ohm 200W Resistor (2x50 ohm/100W ea.) was not ON, the nylon
Entry  Fri May 16 08:44:27 2014, Raymond Dubé, Routine, General, OLIS work next week OLIS-Work-05.pdf
Attached is the scheduled work for OLIS next week.
Entry  Wed Jan 29 12:27:57 2014, Raymond Dubé, , , OLIS Skimmers BOP & Labels isk4363d-rev4.pdfisk4365d-rev2.pdf
I updated 2 drawings that show the OLIS skimmers.
A.  ISK4363D for the OLIS Skimmers BOP connections, we have 7 skimmers cables (6 wires per cable) going in
and 16 skimmers channel going out to Controls.
Entry  Fri Jan 24 09:15:10 2014, Raymond Dubé, , , New ISK4586D for OLIS with 3 Ion Source ISK4586D-rev1.pdf
I created a new drawing: ISK4586D that shows the Optics for OLIS with 3 Ion Source.
Entry  Thu Jan 23 12:56:14 2014, Raymond Dubé, , , New & updated drawings for S.S. ISK4478D-rev5.pdfISK4585D-rev2.pdfISK4583D-rev5.pdf
I updated an old drawing ISK4478D (MS & MCIS Optics) and created 2 new ones: ISK4583D (Electrical Diagram for SS
& MS) and ISK4585D (SS & MS Optics)
If you see any errors please let me know.
Entry  Wed Jan 22 10:34:58 2014, Raymond Dubé, , , IN-line 100K for IOS:YCB1A removed 
Last January 17th 2014 we removed an in-line resistor (100K 10W) from IOS:YCB1A because we do not think that it is needed.
 
Entry  Mon Dec 17 14:10:22 2012, Keerthi Jayamanna, , , Gas flow controller fault 
Controls group may need some assistance from OLIS group in order to trouble shoot the problem.
Entry  Mon Dec 17 14:08:52 2012, Keerthi Jayamanna, , , IRIS beam delivary is completed 
IRIS beam delivery is completed with extra 3 days of beam providing to them.
18O2 and 40Ar+2 were delivered with few attenuators i place.
Entry  Fri Dec 14 17:30:47 2012, Keerthi Jayamanna, , , 18OH2 and 40Ar+2 delivary 
During the last week we delivered 18O+2 from microwave ion source to Ritu.
Over the week end changed to 40Ar+2.
Ritu informed us 18OH2 is coming with 40Ar+2.
Entry  Sun Dec 2 23:36:13 2012, Keerthi Jayamanna, Routine, General, 16O+2 is ready for tuning. 
MCIS finished xenon development. MCIS is off and isolation valve is shut.
A new oxygen gas line is installed to microwave ion source via a hand valve neat PE.
Hand valve is tuned as a small leak so that the plasma can run with all other gas valves are shut.
Entry  Sun Dec 2 22:34:09 2012, Keerthi Jayamanna, , , Just finished 136Xe+25. ISAC reached 1GeV yesterday using OLIS Xe beam 
 
Entry  Sun Dec 2 22:32:19 2012, Keerthi Jayamanna, Routine, General, Still cannot write anything other than Subject 
 
Entry  Wed May 23 17:11:57 2012, Keerthi Jayamanna, , , Changed beam to 12C++ beam 
Removed titanium from the back plate and clean the source.
But left the PE titanium insert since Bob and Marco badly want the 12C++ beam from the source fast.
Background 12C++ was only 400pA so installed a small canister with CO in it with bellow atm. pressure.
Entry  Thu Nov 10 09:57:57 2011, Damien Gallop, , , OLIS Shutdown Picture_3.png
Supernanogan on overnight with 36Ar+7 on FC6. Nice.
Today is the last day of scheduled OLIS Shutdown. Expect more source development today followed by a hand-off to ICR at some point.
Entry  Wed Nov 9 11:40:35 2011, Damien Gallop, , , OLIS Shutdown Picture_8.pngPicture_9.png
Supernanogan 36Ar+7 source development in progress. RF frequency scans are the agenda for today.
Later... Some good beam results and 300enA beam on FC6. Note: 5mm slits are in.
Entry  Tue Nov 8 10:02:54 2011, Damien Gallop, , , OLIS Shutdown Picture_3.pngPicture_4.pngPicture_5.pngPicture_7.pngPicture_6.png
Supernanogan is online with 36Ar+7 on FC6 overnight. Looks good. Note: The source gas arrangement (enriched 36Ar) utilizes double buffer canisters and
calibrated leaks, and requires MCIS:TP3 off.
Controls is preparing to perform an IOSIOS reboot for the sake of new code for ILT:RPM8 or something like that.
Entry  Mon Nov 7 09:58:17 2011, Damien Gallop, , , OLIS Shutdown Picture_2.pngPicture_1.png
IOS pumped well over the weekend. Present pressure is 1.5e-7. MCIS pumps off
for setup.
Later... Supernanogan is online with better than 250enA of 36Ar7+ on FC6 presently ~17:00. Note: MCIS:TP3 is off by intention for this run.
Entry  Fri Nov 4 09:41:32 2011, Damien Gallop, , , OLIS Shutdown Picture_22.png
MCIS continues to pump well. IOS DB assembly planned for today.
Later... DB assembly complete and IOS under vacuum. Present pressure: 1e-6 Torr at ~18:00. All optics hold voltage.
Entry  Thu Nov 3 09:50:05 2011, Damien Gallop, , , OLIS Shutdown Picture_21.png
MCIS pumped well overnight. Source development imminent.
Later... possible IOS intervention. Spin down turbos in anticipation... Meanwhile, MCIS pressure was at 7.8e-8 Tott at the start, and dropped to
7.4e-8 Torr immediately upon closure of MCIS:IV1. Note that IOS:IV0 remains open with interlocks bypassed.
Entry  Wed Nov 2 10:16:49 2011, Damien Gallop, , , OLIS Shutdown Picture_21.png
MCIS pumpdown continues well. IOS optics coming along. DB3 installed last night and IOS is under vacuum very early. DB1/2 optics will remain out until
the end of the next-up MCIS run.
Entry  Tue Nov 1 10:18:02 2011, Damien Gallop, , , OLIS Shutdown Picture_20.png
MCIS pumped overnight. Still coming down.
Entry  Mon Oct 31 11:06:58 2011, Damien Gallop, , , OLIS Shutdown grab.g18922.png
Two weeks of OLIS Shutdown have begun. The plan is to complete refurbishing this week and pump next week, with 36Ar+6 beam ready at the end of it. IOS
is vented and open. The Supernanogan cart is out, vented and open. Plasma chamber cleaning and refurbishing in situ are in progress. The IOS upstream optics
DB1-3 have been removed for refurbishing on the bench.
Entry  Mon Oct 31 11:04:06 2011, Damien Gallop, , , 33S+6 from MCIS to DRAGON EOB Picture_17.png
Deliver concluded yesterday morning around 09:00.
Pity to have to switch off the source. OLIS is now in its Shutdown.
Entry  Fri Oct 28 10:18:53 2011, Damien Gallop, , , 33S+6 from MCIS to DRAGON Picture_16.png
Delivery continued overnight.
Entry  Wed Oct 26 10:17:53 2011, Damien Gallop, , , 33S+6 from MCIS to DRAGON Picture_13.pngPicture_14.png
Delivery continued uneventfully overnight
and is continuing.
Later... source is just getting better and better. See Stripchart below.
Entry  Tue Oct 25 09:41:32 2011, Damien Gallop, , , 33S+6 from MCIS to DRAGON Picture_12.png
Beam petered out earlier this morning after an attempt to tweak the RF frequency. Restored. Plasma was on throughout. ICR has lowered RF amplitude to
match beam intensity to yesterday's running conditions.
Entry  Mon Oct 24 10:10:34 2011, Damien Gallop, , , 33S+6 from MCIS to DRAGON Picture_10.png
Delivery since Friday Beam on but intensity
is dropping, suggesting that enriched 33S powder is running out. Plan in place to add more this evening.
Entry  Wed Oct 19 09:53:27 2011, Damien Gallop, , , 33S from MCIS to HE Development Setup Picture_9.png
MCIS configured for 33S+6 yesterday afternoon. Beam grew nicely overnight. Beam development expected after source hand-off.
Entry  Tue Oct 18 10:27:44 2011, Damien Gallop, , , 19F/38Ar from MCIS for Beam Development Picture_7.png
Cocktail beams continue today.
Entry  Mon Oct 17 11:33:03 2011, Damien Gallop, , , 19F/38Ar from MCIS for Beam Development 
Source set up for a cocktail beam since yesterday, Sunday.
Entry  Thu Oct 13 11:11:14 2011, Damien Gallop, , , 14N+2 from MWS to SEBT for Beam Development Picture_5.png
Source setup took place earlier this morning.
Entry  Thu Oct 6 15:15:09 2011, Damien Gallop, , , 19F/40Ar from MCIS for Beam Development Picture_4.png
Slit calibration exercise was wound up this morning. MCIS source gases were reconfigured with 19F and 40Ar by request. A "cocktail" beam will
be used for HE development over the Thanksgiving weekend. A mass scan is in progress presently.
Entry  Wed Oct 5 10:11:28 2011, Damien Gallop, , , 33S from MCIS Source Development Picture_1.png
The source stayed up overnight. A little RF tweak, but 33S+6 beam still on FC6.
Later... IOS:MCOL3 slits calibration with beam in progress.
Entry  Tue Oct 4 10:37:38 2011, Damien Gallop, , , 33S from MCIS Source Development Setup Picture_24.pngPicture_25.png
Beam development with 116Sn+18 finished last evening around 21:00. Source was off overnight. 33S material loaded into MCIS oven. Source pumped overnight.
Later... source is lit. 33S+6 on FC6 and growing.
Entry  Mon Oct 3 10:08:50 2011, Damien Gallop, , , 116Sn+18 & 118Sn+19 from MCIS for Development Picture_22.pngPicture_23.png
On Friday there was a request to repeat some of the findings with tin beams. An agreement was made to use OLIS for development in lieu of Shutdown MRO
as scheduled. MRO is planned for November 2nd &ff. HE development took place over the weekend with 116Sn+18, A/q=6.44.
Next up: 33S source development. Setup this evening.
Entry  Thu Sep 29 10:50:30 2011, Damien Gallop, , , 36/40Ar development with MCIS 
Development with Supernanogan source continues. Present beam is 40Ar+7, about 70enA.
Entry  Wed Sep 28 11:56:15 2011, Damien Gallop, , , 36/40Ar development with MCIS Picture_21.png
40Ar source gas, ergo 40Ar+x beams. 40Ar+6 earlier, and 40Ar+7 presently.
Entry  Tue Sep 27 13:29:23 2011, Damien Gallop, , , 36/40Ar development with MCIS 
Beam development for forthcoming 36Ar run is in progress. Initial yield numbers have been determined. Source is running with Ar plasma presently, and
tests will be repeated after source has conditioned for a while. The goal is to determine yield numbers of 40Ar and scale these to beam to be produced
with source gas of enriched 36Ar. FYI:
Entry  Mon Sep 26 09:47:12 2011, Damien Gallop, , , 13C+3 from MCIS to TACTIC Picture_20.pngPicture_19.png
The 17O+3 (A/q=5.66) run to TACTIC finished yesterday morning. Then a source switchover
was done to deliver 13C+3 (A/q=4.33) using enriched 13CO2 source gas.
Later... TACTIC is done. Next up: beam development at MCIS for upcoming 36Ar run.
Entry  Fri Sep 23 14:59:14 2011, Damien Gallop, , , 14N+3 & 17O+3 from MCIS to TACTIC at HEBT Picture_16.pngPicture_17.pngPicture_18.png
Delivery continues. 14N+3 until mid-morning, then a switch to 17O+3 for tuning. The switchover from 116Sn to TIGRESS to 14N+3 to TACTIC was done on Tuesday mid-morning.
Entry  Mon Sep 19 10:27:36 2011, Damien Gallop, , , 116Sn+18 & 118Sn+19 from MCIS to TIGRESS Picture_15.png
Delivery continued over the weekend with some interruptions here and there. A source intervention was made late last night and into the wee hours, and
again this morning. Tuning to TIGRESS has resumed.
Note that ICR was using a 12C+2 beam for setup purposes. Their procedure was to turn off MCIS when beam not in use to minimize carbon contamination
Entry  Fri Sep 16 10:02:33 2011, Damien Gallop, , , 116Sn+18 & 118Sn+19 from MCIS to TIGRESS Picture_12.png
Beam was changed to 14N+2 last evening for sake of tuning to front of RFQ. Source was tweaked earlier. Beam is presently set to 116Sn+18 with tuning
activities in progress.
Entry  Thu Sep 15 12:09:25 2011, Damien Gallop, , , 116Sn+18 & 118Sn+19 from MCIS to TIGRESS Setup Picture_6.pngPicture_7.pngPicture_10.png
Source switchover began last night after 22:00. There are some 200epA of A/q=6.46 (116Sn+18) on FC6 presently. Setup and tuning continue.
Natural abundances of Sn:
Sn-116   ( 14.54% ) 
Entry  Thu Sep 15 11:29:39 2011, Damien Gallop, , , 12C+2 from MCIS to DRAGON EOB Picture_5.png
Beam delivery was scheduled to end last evening at 20:30. It was extended to around 22:00, at which point source switchover began.
Entry  Wed Sep 14 10:00:05 2011, Damien Gallop, , , 12C+2 from MCIS to DRAGON Picture_2.png
Delivery continues. Nice consistency. See attached Stripchart. A source switchover is scheduled for today, tonight, as it turns out. Good luck with that.
Entry  Tue Sep 13 10:00:56 2011, Damien Gallop, , , 12C+2 from MCIS to DRAGON Picture_1.png
Delivery continued through the night. User was taking the beam. Recovery from a DTL tank trip is happening at the moment. Otherwise, beam is very good.
And strong.
Entry  Mon Sep 12 10:07:36 2011, Damien Gallop, , , 12C+2 from MCIS to DRAGON Setup Picture_3.pngPicture_4.png
Setup began around 09:00. 400enA of A/q=6 on FC6 presently.
Later... By ~14:00 beam looks pretty good. See Stripchart below.
Entry  Mon Sep 12 10:04:42 2011, Damien Gallop, , , 4He from MCIS to DRAGON EOB Picture_1.pngPicture_2.png
Delivery continued through the weekend. Some 300nA on FC6. The run ended at around 09:00. Source switchover is in progress now.
Entry  Thu Sep 8 11:21:45 2011, Damien Gallop, , , 4He from MCIS to DRAGON Setup Picture_53.png
The 58Ni delivery from MWS to TITAN ended last evening. Beam was unused from about 18:30, and source switchover began at about 22:00. A 4He1+ beam from
MCIS was established by 03:00 this morning.
Around 35pA is available on FC6 presently. Note that at A/q=4, there are likely contributions from 12C+3 and 16O+4.
Entry  Wed Sep 7 09:50:20 2011, Damien Gallop, , , 58Ni1+ from MWS to TITAN Picture_52.png
Delivery continues. Source change scheduled for 20:30 this evening.
Entry  Tue Sep 6 16:37:24 2011, Damien Gallop, , , 58Ni1+ from MWS to TITAN Picture_50.png
Pilot beam delivery continues. Keerthi came in over the Labor Day weekend to help out on something.
Beam is scheduled for one more day. A source change is scheduled for 20:30 tomorrow.
Entry  Fri Sep 2 10:04:55 2011, Damien Gallop, , , 58Ni1+ from MWS to TITAN 9x
Beam idled overnight. Average ~50pA at FC6. About half that on ILE2T:FC3 presently. Setup on TITAN side in progress.
Later... ICR is concerned about the OLIS separator magnet wandering during the day. It's sunny today, so I would expect a little more wandering
than on a rainy day. Also, they have significantly higher current at A/q >58.1 and asked if there could be another mass in the mix. Checking.
Entry  Thu Sep 1 10:01:25 2011, Damien Gallop, , , 58Ni1+ from MWS to TITAN Picture_39.png
Beam was established yesterday. It has grown nicely overnight.
Entry  Wed Aug 31 12:12:39 2011, Damien Gallop, , , 58Ni1+ from MWS to TITAN Setup Picture_37.pngPicture_38.png
Beam on FC6 drifted overnight. Touch up a few things, notably the EE. 25pA on FC6 presently. I also increased microwave power for effect.
Later... about 25pA on FC6. Somewhat noisy, but also stable. I left microwave at 700W. Beam handed over to ICR at ~13:15.
A note about mass flow controller. The new Hastings controllers do indeed shut off completely at zero setting. It should be noted that control
Entry  Tue Aug 30 16:40:14 2011, Damien Gallop, , , 58Ni1+ from MWS to TITAN Setup Picture_33.pngPicture_34.pngPicture_36.png
Source switchover from MCIS to MWS. Support gases and liners were pre-fitted. Source lit. Optics set for 20keV operation. ~50pA on FC6.
Entry  Tue Aug 30 10:01:30 2011, Damien Gallop, , , 17O3+ from MCIS Reserved Picture_32.png
We are on orders to retain OLIS for accelerator development. The switchover to 58Ni, scheduled for this morning, is on hold.
Meanwhile, there were WFB1 and PV1 trips this morning. All reset and beam is on. The WFB paddle for the MCISRFS circuit was still rotating at a
reasonable rate. I adjusted the WFB setting for ON state with minimum flow.
Entry  Mon Aug 29 10:03:05 2011, Damien Gallop, , , 17O3+ from MCIS to DRAGON 
Delivery continues on autopilot. Looking good.
ICR noted that a seemingly unusual number of tweaks to the IOS separator magnet have been required. This is not so surprising, given that the magstab program
is not running presently. It is expected that today will be EOB for DRAGON. A switch to 58Ni is on deck.
Entry  Thu Aug 25 10:54:34 2011, Damien Gallop, , , 17O3+ from MCIS to DRAGON Picture_24.pngPicture_25.pngPicture_26.pngPicture_27.pngPicture_28.png
Delivery continues.
Entry  Wed Aug 24 10:49:41 2011, Damien Gallop, , , 17O3+ from MCIS to DRAGON Picture_20.pngPicture_21.pngPicture_22.png
Delivery continues. There were several "PV1" trips over the past several days. ICR now has a recipe for resetting this condition. We await
a general instruction from ICR via email.
Meanwhile, MCIS:TP3 was off for the last while. ICR notified. Investigating. Turned on again.
Entry  Mon Aug 22 09:49:34 2011, Damien Gallop, , , 17O3+ from MCIS to DRAGON Picture_25.png
Delivery continues. The attached vacuum trar suggests that this is about as good as it's going to get. On the other hand, there is a uA of beam
on FC6.
Entry  Fri Aug 19 10:01:52 2011, Damien Gallop, , , 17O3+ from MCIS to DRAGON Picture_20.pngPicture_21.png
Setup in progress. No foil at M:5. Source has been running since yesterday. Note that source was opened recently for MRO. Vacuum pumpdown chart for past
several days attached.
Later... ~10:00 ICR reported MCIS:PV1 closed. On closer inspection, it was pretty clear that the classic PLC "all PVs go to zero" state
Entry  Mon Aug 15 10:19:18 2011, Damien Gallop, , , 84Kr from MWS to TITAN Picture_18.pngPicture_17.png
The source was configured and switched over on Friday. Some teething pains over the weekend. Beam is on FC6 presently.
Entry  Mon Aug 8 17:08:28 2011, Damien Gallop, , , Supernanogan MRO grab.w19243.pnggrab.q19378.png
Cart removed for source servicing. Source opened and split at front seal. Ground and plasma electrodes removed. All internal areas cleaned. Source reassembled.
Initial pumping in progress. Leak-up curve a little soft, but reasonable given the cleaning materials used: methanol, acetone, Simple Green.
Entry  Wed Aug 3 00:15:39 2011, Keerthi Jayamanna, Other, General, 22Ne+2 
Source started at 800W of microwave power and 2cc/min neon gas easily. New magnetron produces more power than the old one.
We should try to keep MW power under 500W during running and use only 800W for ignition.  EE left off for the night.
Entry  Fri Jul 22 15:56:08 2011, Damien Gallop, , , 27Al+1 from MWS for DRAGON status Picture_7.png
There have been teething pains developing a good 27Al beam. The Supernanogan sputter source ate through aluminum rods like candy. The MWS worked for
a while, but would not hold a sustained plasma. IOS was opened a couple of times to clean the MWS. It ran for a while today, then blinked out. Leak checking
is in progress. But the source looks pretty tight from that point of view.
Entry  Wed Jul 20 01:37:46 2011, Keerthi Jayamanna, , , Al beam development: 
 
Supernanogan is tested for Al+6 beam production.
A 8nA of mass 4.5 is seen. Background pressure is not good enough to
produce
more Al+6. Attempt to increase Al beam current with higher sputtering
voltages resulted in fast destruction of the Al sample.
Decided
Entry  Tue Jul 19 17:02:44 2011, Damien Gallop, , , 27Al+1 from MCIS Setup Picture_5.png
The DRAGON run finished this morning. Switchover to 27Al+6 in progress now.
Entry  Mon Jul 18 10:02:42 2011, Damien Gallop, , , 24Mg+6 from MWS for DRAGON Picture_2.pngPicture_3.pngPicture_4.png
Keerthi came in early this morning to set up OLIS for 24Mg delivery. HEBT tuning is in progress.
Entry  Mon Jul 18 09:53:05 2011, Damien Gallop, , , 4He from MCIS to HERACLES done Saturday and Sunday 
Keerthi came in on Saturday morning and set up the Supernanogan source for 4He delivery. It looks like it went well. The original intent was to use the
MWS for this, but sputtering got in the way. He also came in yesterday to tweak the recipe to minimize 16O4+ and 12C3+ (A/q=4) contribution to the beam.
The run finished last night.
Entry  Fri Jul 15 10:30:11 2011, Damien Gallop, , , 24/25Mg+1 from MWS for HERACLES on SEBT1 Picture_6.pngPicture_7.pngPicture_8.pngPicture_9.pngPicture_10.png
25Mg beam mostly sitting on FC6 now, as HERACLES takes RIB. Source was opened
on Monday night to replace microwave window. Beam will be u sed again towards the end of the HERACLES run, then EOB tomorrow morning, Saturday.
Entry  Mon Jul 11 09:46:07 2011, Damien Gallop, , , 24/25Mg+1 from MWS for HERACLES on SEBT1 
Well, the plasma electrode shorted again, and Keerthi came in on Saturday to tear down the MWS and clean it. Beam is steady as she goes presently. Delivery
continues today in lieu of RIB unavailability for today. A switch to RIB is expected this evening.
Entry  Fri Jul 8 10:07:14 2011, Damien Gallop, , , 24/25Mg+1 from MWS for HERACLES on SEBT1 8x
 
Beam on FC6 overnight and very stable. It grew overnight and continues to grow, but hasn't hit 1pnA yet. Marco is tuning with what he has. Let's
see how it goes.
Entry  Thu Jul 7 10:40:27 2011, Damien Gallop, , , 24/25Mg+1 from MWS Setup 6x
Source conditioned nicely overnight at 55kV with a little RF power on. Source gases checked, final cage inspection. Ready to start.
Later... Source is lit. Let it grow.
Later... Lots of beam on FC3 but not a lot on FC6. Beam is broad. Hand it over to ICR for the night as-is.
Entry  Wed Jul 6 13:20:15 2011, Damien Gallop, , , 24/25Mg+1 from MWS Setup grab.jS3278.pnggrab.FQ5737.png
Source opened, and aluminum components removed. Magnesium components from previous run cleaned and installed. Pumpdown in progress.
Later... Pumpdown looks wonderful. A couple of cycles with partial vent with N2 to help evaporate the methanol.
Later... Power is on. HV at 55kV for the night to condition. No plasma, no beam overnight.
Entry  Wed Jul 6 09:56:45 2011, Damien Gallop, , , 27Al+1 from MWS for DRAGON EOB 13x
DRAGON has been taking beam since approximately noon on Monday, and finished a little while ago. Feedback I have received is that beam intensity was
lower than experimenters' ideal, but quality of the beam was very good. I will run an emittance scan shortly. Then next up: Mg setup.
Entry  Sun Jul 3 09:56:47 2011, Damien Gallop, , , 27Al+1 from MWS Setup grab.N30246.pnggrab.e30256.pnggrab.M30261.pnggrab.i30265.pnggrab.X30290.png
A lot has happened since the last entry. The source blinked out at some point. Cause cited was a PE short. Actions were taken, to be detailed later.
Source was re-lit. Beam on FC6 was unstable yet promising overnight last night. In the wee hours it blinked out again and is out presently. Remotely checked
vital signs. The only thing that appears to require immediate intervention is the source gas line, which looks very closed. ICR assisted with a check on
Entry  Thu Jun 30 10:02:08 2011, Damien Gallop, , , 27Al+1 from MWS Setup Picture_2.pngPicture_3.pngPicture_4.pngPicture_5.png
Source pumped overnight to previous baseline (red trace on attached Stripchart). IOPS conditioned it up to 42kV without a hitch.
Close Ne source gas line and pump out flow controller... noticeable improvement.
Bias conditioned up to 50kV.
Entry  Wed Jun 29 15:49:16 2011, Damien Gallop, , , 27Al+1 from MWS Setup grab.Q27242.png
Switchover from 58Ni+1/MCIS to 27Al+1/MWS began just after noon. MWS cleaned and fitted with aluminum liners. Pumping in progress. Good leakup curve.
All electrostatics checked and operational. Source should be conditioned to at least 55kV at some point. Let it sit at 30kV overnight with 100W on MW.
Entry  Wed Jun 29 09:45:50 2011, Damien Gallop, , , 58Ni from MCIS to TITAN 8x
Last hours and minutes. Going well. Documentation appended. Users have requested beam until noon.
Note: We are using the MWS bias and EE power supplies on the Supernanogan source for this run, to provide source bias and also sputter chamber
bias for the Supernanogan.
Entry  Tue Jun 28 09:32:09 2011, Damien Gallop, , , 58Ni from MCIS to TITAN Picture_4.png
Beam mostly idle overnight. Things are resuming now.
Entry  Mon Jun 27 10:20:41 2011, Damien Gallop, , , 58Ni from MCIS to TITAN Picture_1.pngPicture_2.png
From MCIS. It looks like things went fairly well over the weekend for them. An interlock glitch on MCIS:IV1 this morning, source pressure went slightly
above MCIS:IG1 "Good" threshold. I have suggested to Tiffany that raising the "Good" threshold to 1e-7 might be a good idea. Because
we are intentionally running with MCIS:TP3 off, the source pressure is higher. It's right on the edge of the current "Good" threshold. Attached
Entry  Fri Jun 24 15:11:20 2011, Damien Gallop, , , 58Ni from MCIS to FC6 Setup 
OLIS was switched from 22Ne2+ (MWS) to 58Ni+1 (MCIS). Works like magic. 100epA presently.
Entry  Fri Jun 10 11:35:24 2011, Damien Gallop, , , 22Ne2+ for TUDA-II Pilot Beam 
MWS online. Beam sitting on FC6.
Mel returned two flow controllers today, borrowed in March and April.
Entry  Thu Jun 9 16:51:09 2011, Damien Gallop, , , 22Ne2+ for TUDA-II Pilot Beam Picture_1.pngPicture_4.pngPicture_3.pngPicture_2.pngPicture_5.png
MWS online. Note: A/q display is white. Possible culprit: IOSIOC. ICR will reboot it at first convenient opportunity.
Earlier, Supernanogan was set up with empty canister in preparation for Kr heavy ion run planned for this weekend. Canister and lines pumpdown
in progress. However, a FR was issued for MCIS:BP1, which is losing ground pretty quickly. The two MCIS screenshots below were taken some five minutes
Entry  Mon May 30 14:44:01 2011, Damien Gallop, , , 22Ne2+ for ICR Training IMG_0093.jpg
MWS online. Separator magstab program offline. Check: Kepco is switched off and one lead is physically cut and taped over. That's pretty definitive.
Later... Keerthi has found that the EPICS probe has more diurnal variation than the separator power supply itself, so he disconnected it permanently.
There is a USB issue with using our precision Hall probe that will require some expert Linux assistance to resolve.
Entry  Mon May 2 10:50:28 2011, Damien Gallop, , , Alkalis for DRAGON EOB 7x
DRAGON has been taking various species of Na and Rb using the MWS. Run ended this morning. Emittance scan of 23Na attached. Mass scan in progress.
Entry  Fri Apr 1 17:02:09 2011, Damien Gallop, , , 12C2+ for Startup 
Supernanogan is online with a bit of 12C2+ beam on FC6. Mag stability program is running. Source development to follow.
Hastings Teledyne flow controller lent to Mel.
Entry  Tue Mar 29 15:32:08 2011, Damien Gallop, , , Controls and Panel MRO 
Controls is working on an interlock issue. Electrical panel MCC-X maintenance is planned for tomorrow afternoon.
Loaned a Horiba SEC-7320 flow controller to Mel. This unit belongs to Friedhelm.
Entry  Fri Mar 25 17:42:38 2011, Keerthi Jayamanna, , , OLIS HV start up 
High Voltage cage is on at ~17:43pm
Interlock cleard and HV (10kV) is on at 17:53pm
Entry  Wed Mar 9 11:09:02 2011, Keerthi Jayamanna, , , IOS:SSW failed 
IOS:SSW failed unexpectedly. No reason found. Came back on easily.
Entry  Sat Feb 26 22:06:03 2011, Keerthi Jayamanna, , , Ti+7 status 
90pA of Ti+7 is running smoothly. 22:05  Feb26th
Entry  Fri Feb 25 17:27:11 2011, Keerthi Jayamanna, , , Titaniums efficiency test 
Small peice of titanium wire is installed and running aroung 100pA of Ti+7 at FC6.
OSAC are OPs taking data.
Entry  Fri Feb 25 17:27:11 2011, Keerthi Jayamanna, , , Titaniums efficiency test 
Small piece of titanium foil 0.0005" thick is installed and running around 100pA of Ti+7 at FC6.
OSAC are OPs taking data.
Entry  Wed Feb 23 22:29:48 2011, Keerthi Jayamanna, , , OLIS mahnet 
Klixon at the OLIS bemding magnet is not funtioning properly.
Entry  Tue Feb 22 18:54:43 2011, Keerthi Jayamanna, , , EE and SSEE 
Both EE and SSEE problems were solved. They are working OK now.
Entry  Tue Feb 22 18:52:53 2011, Keerthi Jayamanna, , , Ti+7 efficiency studies 
2mm diameter Ti was installed to set the optics. Later 0.0005 in thick foil will be installed for real efficiency studies.
Entry  Fri Feb 18 11:43:32 2011, Keerthi Jayamanna, , , IOS: EE Status 
IOS:EE found damaged. It has been replaced with IOS:SSEE-Michael B.
Entry  Fri Feb 18 11:05:50 2011, Keerthi Jayamanna, , , OLIS Problems 
PE set point is ok but read back is half of the real value.
Entry  Fri Dec 24 13:06:07 2010, Damien Gallop, , , Merry Christmas and Happy New Year 
Our very best to all of you.
Entry  Tue Dec 21 09:43:22 2010, Damien Gallop, , , In Memoriam... Mike McDonald Mike1526.jpg
At 5:00 this morning, after a lengthy battle with cancer, Mike passed from this life to his eternal reward. He has left us a great legacy. May he rest
in peace.
Entry  Mon Dec 20 09:50:07 2010, Damien Gallop, , , MCIS Development & EOB Picture_5.pngAu_Scan.pngAu_Scan_Zoom.pngAoverQ.png
Development and the quest for gold continue.
Later... Mass scans in region of 197Au33 A/q=5.97, with graph of all theoretically possible charge states in the same A/q region. The thing to
note in that last graph is how clean is the region (just left of A/q=6) where 197Au33 is predicted.
Entry  Fri Dec 17 09:18:57 2010, Damien Gallop, , , MCIS Development Picture_1.png
Development continues in the search for gold. A=197 Present A/q=5.94, which suggests 197Au+33. It could also be a tail of 12C+2. We'll see.
Entry  Wed Dec 15 09:18:41 2010, Damien Gallop, , , MCIS Development 
Source development in preparation for Au beam in progress.
Entry  Tue Dec 14 09:15:58 2010, Damien Gallop, , , MCIS Development 
Beam development started yesterday. Looks like the HERACLES run, which started Thursday,
ended yesterday morning.
Entry  Tue Dec 7 08:57:26 2010, Damien Gallop, , , 80Kr14+/40Ar7+ for SEBT Development Picture_1.png
Development should continue today. Looks like Supernanogan went through a plasma mode change overnight and settled into a new mode.
Entry  Mon Dec 6 09:08:52 2010, Damien Gallop, , , 80Kr14+/40Ar7+ for SEBT Development Picture_1.pngPicture_2.pngNoKr.pngWithKr.pngmass7point333.png
The previous 12C2+ development run from the Supernanogan ended Friday morning. Starting Friday afternoon, the Supernanogan was prepared for an upcoming
SEBT development using krypton beams. The source was ready overnight.
There were some teething pains over the weekend. An A/q=5.71 beam is sitting on FC6 presently. The beam schedule shows an experiment change on Thursday
Entry  Fri Dec 3 09:37:14 2010, Damien Gallop, , , 12C2+ for Commissioning 15x
Last moments of beam development for SEBT commissioning. Attached is an FC6 plot and the present optics and 1mm slits. Decision was to not do a vertical
emittance scan at this time, but proceed with 15Kr development, up next. Before we shut off, one last emittance scan coming up.
Later... Emittance scan with 2.5mm slits (default position setting used) in progress... Done. 101203_1017ILTEMIT.txt.
Entry  Thu Dec 2 10:02:46 2010, Damien Gallop, , , 12C2+ for Commissioning 14x
Accelerator development continues. Save: 101201_2157.snaiosvault. Today's agenda: emittance scans. Attached: overnight beam plus a preliminary horizontal
emittance scan 101202_0951ILTEMIT.txt.
Later... First good scan 101202_1016ILTEMIT.txt.
Entry  Wed Dec 1 08:51:54 2010, Damien Gallop, , , 12C2+ for Commissioning Picture_2.png
Continuing from Supernanogan. Source touch-up last evening.
Entry  Tue Nov 30 08:47:47 2010, Damien Gallop, , , 12C2+ for Commissioning Picture_1.png
Commissioning and development continue.
Entry  Mon Nov 29 08:55:35 2010, Damien Gallop, , , 12C2+ for Commissioning Picture_11.png
Supernanogan is online. MCIS:TP3 is off. It should be on. It is required for best production of higher charge states.
Entry  Thu Nov 25 11:50:14 2010, Damien Gallop, , , 12C2+ for Commissioning Picture_8.png
Some start-up teething pains last night. Decision: Go with the Supernanogan for now. ~20enA on FC6. Save: 101125_1148.snapiosdragon. Also, a CANBUS card
on IOS:YCB1A failed this morning and was replaced by Controls.
Entry  Wed Nov 24 17:08:41 2010, Damien Gallop, , , 12C2+ for SEBT Commissioning grab.lq8147.png
Source switchover began at ~15:00.
Entry  Wed Nov 24 14:02:14 2010, Damien Gallop, , , 85Rb for TITAN Picture_5.pngPicture_6.pngPicture_7.png
Last day of 85Rb delivery. Save: 101124_1400_snapiostitan. Next up: 12C2+ for SEBT commissioning. We took a few minutes earlier
to see if this is available with the source as-is. No such luck. Plan is to shut off mid-afternoon, and prepare to switch over to 12C2+ operation from
the MWS.
Entry  Tue Nov 23 10:31:27 2010, Damien Gallop, , , 85Rb for TITAN Picture_3.png
We are back to running a Rb beam using the MWS. The run started last Thursday, November 18th. The previous Rb run ended on Monday, November 8th, at which
point a 12C2+ beam was established, using both sources; the Supernanogan was selected for final delivery to DRAGON. Users reported excellent beam. That
run ended last Monday, November 15th, after
Entry  Wed Nov 10 09:18:31 2010, Damien Gallop, , , 12C2+ for DRAGON Picture_2.pngPicture_3.png
12C2+ beam established yesterday from the Supernanogan. Tuning to DRAGON began last evening and is continuing presently.
We noticed that MCOL0 no longer has a valid reading. A quick trar suggests it stopped reading at around 17:00 yesterday, right around the beam
hand-off time. Also, after working fine since Controls adjusted it a couple of weeks back, the MCIS:RFS water flow meter began toggling its state again
Entry  Tue Nov 9 08:42:38 2010, Damien Gallop, , , 12C2+ for DRAGON Picture_1.pngPicture_1.png
A good 12C2+ beam was established yesterday from the Supernanogan source, driven by background pressure only; no source gas actively injected. Beam intensity
was not sufficient, so we switched to the MWS. 12C2+ from the MWS sat on FC6 for the night, and grew over the time. Plan today: increase the intensity
one way or another.
Entry  Mon Nov 8 09:37:03 2010, Damien Gallop, , , 12C2+ for DRAGON Picture_1.png
The 85/87Rb run from the MWS ended last evening as scheduled. The Supernanogan source was brought online (~21:30 Sunday?) and a 12C2+ beam established,
first for ICR training then for DRAGON setup.
Entry  Fri Nov 5 09:23:53 2010, Damien Gallop, , , 85Rb for Polarizer Picture_1.png
Beam was used yesterday. Mostly idle overnight. Looks like a plasma mode change happened at around 19:00 yesterday. It happens. Or perhaps just an artifact
again. Shortly after, beam was moved to 87Rb, which is where it is right now. Once again, another milestone first at OLIS: 87Rb from the MWS.
Natural abundance of Rb: Rb-85   ( 72.165% ) Rb-87 
Entry  Thu Nov 4 09:18:15 2010, Damien Gallop, , , 85Rb for Polarizer Picture_1.png
Source ran nicely overnight. ICR team set up a tune into the Polarizer line. Experiment setup is scheduled to start tomorrow morning.
Entry  Wed Nov 3 09:22:38 2010, Damien Gallop, , , 85Rb for Polarizer Picture_2.pngPicture_1.png
Yesterday we handed over a 85Rb beam to ICR. It will be used for a LEBT run using the Polarizer line. Beam stayed on FC6 overnight. Note the source spark
at around midnight, after which the bias current readback was higher. Real or artifact?
Later... Beam status over last couple of hours. Looks like tuning has begun.
Entry  Tue Nov 2 09:25:30 2010, Damien Gallop, , , MWS Development Picture_1.pngPicture_1.png
85Rb on FC6 overnight. After restarting the source yesterday following development, the beam intensity came back, but it's slightly unstable compared
to before. Mag stability program is active.
Later... Work with the source for a while. Improved. Stripchart attached. Time will tell. Save: 101102_14:30.snapiosfc6.
Entry  Mon Nov 1 09:30:15 2010, Damien Gallop, , , MWS Development Picture_45.pngPicture_1.pngPicture_2.pngPicture_3.png
The source stayed up steadily over the weekend, with 85Rb on FC6. Not a lot of current, but pretty good for a first pass. More development today. Source
settings shown below. As previously noted, the 2.5mm slits are selected. Also, the present IOS tune is for effect, not by the book.
Next up: Try some variations on the source setup.
Entry  Fri Oct 29 09:41:20 2010, Damien Gallop, , , MWS Development 6x
MWS source switchover yesterday was successful. Leakchecking went well. A small leak on the intermediate section sealed with a snug on the two bellows
fixing bolts. The microwave window required cleaning. It tested leak-tight. All good. Pumpdown curve to come. Meanwhile, source was restarted last night.
First 85Rb is on FC6 presently. Although OLIS has run Rb beam in the past using the SIS, this is a milestone for the MWS. Development to proceed today.
Entry  Thu Oct 28 17:51:49 2010, Damien Gallop, , , MWS switchover for scheduled 85/87Rb beams grab.N32655.png
A controls issue with IOS:BIAS was found yesterday. Controls people resolved it today. MWS source was switched over and prepared for Rb beam. Leakchecking
done: tight. Source should pump for a little while longer before energizing. At present, leak detector is attached to the IOS roughing line. Pic attached
with IOS:BP1 alternately online and offline.
Entry  Thu Oct 28 17:51:49 2010, Damien Gallop, , , MWS switchover for scheduled 85/87Rb beams Picture_1.png
A controls issue with IOS:BIAS was found yesterday. Controls people resolved it today. MWS source was switched over and prepared for Rb beam. Leakchecking
done: tight. Source should pump for a little while longer before energizing. At present, leak detector is attached to the IOS roughing line.
Later... Noticed that MCIS:TP2 was tripped off. After a couple of tries, it restarted okay. Hmm...
Entry  Wed Oct 27 09:21:59 2010, Damien Gallop, , , 26Mg6+ for TIGRESS EOB 16x
The experiment ran overnight, smoothly, by the looks of it. Beam is on FC6 now, so they're likely done. EOB studies on Mg beam to commence shortly, with
source teardown and switchover to Rb beam to follow..
Emittance scans in progress, first at as-delivered settings: 5mm slits. Save: 101027_1102>snapiosfc6
Entry  Tue Oct 26 09:19:39 2010, Damien Gallop, , , 26Mg6+ for TIGRESS Picture_1.png
The TIGRESS run was scheduled to end at 08:30, but has been extended for 24h. The ICR reports that they are getting "good data" with the present
beam. Why mess with what works?
We will expect to begin the MWS switchover tomorrow.
Entry  Mon Oct 25 09:05:15 2010, Damien Gallop, , , 26Mg6+ for TIGRESS Picture_3.png
Smooth delivery (from OLIS point-of-view) to TIGRESS over the weekend. An SCB RF amplifier failed yesterday and was replaced. Tuning was done. Source
is stable.
There were a couple of bias sparks over the weekend, expected during Mg runs. The mag stability program got knocked off at some point. Restart
Entry  Fri Oct 22 09:35:24 2010, Damien Gallop, , , 26Mg6+ for TIGRESS 
A 26Mg beam was handed over to TIGRESS last
evening. It is 26Mg6+ through ISAC-I and further stripped to 26Mg10+ by the time they get it. Approximately 2.5pnA at FC6.
Entry  Thu Oct 21 11:46:14 2010, Damien Gallop, , , 26Mg6+ for TIGRESS Picture_14.png
The MWS was restarted yesterday, and a 26Mg beam re-established. ICR set up into ISAC-II overnight, and tuning to TIGRESS
began this morning. Note the experiment change due to circumstances at the RIB
targets.
Entry  Wed Oct 20 11:30:32 2010, Damien Gallop, , , 26Mg6+ for TUDA-II Picture_6.pngPicture_7.pngPicture_9.png
MWS ran fine overnight. It was shut off this morning to investigate bias sparking issue, noted on FR#4894. The two MCIS turbopump controllers are displaying
gibberish on their front panels this morning. There was one spark since yesterday, around 19:15 last evening. Due to a failure
at ITW - see here and here,
Entry  Tue Oct 19 09:20:40 2010, Damien Gallop, , , 26Mg6+ for TUDA-II Picture_1.png
MWS operating nicely.
Entry  Mon Oct 18 09:22:35 2010, Damien Gallop, , , 26Mg6+ for TUDA-II Picture_5.png
MWS is producing 26Mg, presently parked. It was used over the weekend
for TUDA tuning.
Entry  Fri Oct 15 09:23:03 2010, Damien Gallop, , , MWS switchover for scheduled 24/26Mg beams Picture_2.png
Source is running nicely. Hand-off to ICR
occurred ~Wednesday night. Setup done overnight.
26Mg (PE is now on at nominal value) is selected presently; blue trace on Stripchart.
Entry  Wed Oct 13 16:15:03 2010, Damien Gallop, , , MWS switchover for scheduled 24/26Mg beams Picture_1.png
Source conditioning most of today, to 59kV. Striptool attached. Reset to 26Mg tune at ~16:00.
Entry  Tue Oct 12 13:25:21 2010, Damien Gallop, , , MWS switchover for scheduled 24/26Mg beams grab.J26422.pnggrab.J27689.png
Source switchover in progress on WP#2010-10-12-1. Magnesium material
installed into MWS. Pumpdown in progress. Leakup rate OK. Turbos on.
Later... Pumping going well. at 1e-6 by ~16:00.
Entry  Fri Oct 8 09:35:03 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for TIGRESS Picture_1.png
Beam from MWS quietly sitting on FC6 awaiting tune checks to TIGRESS. Next experiments up are 26Alg5+ to TUDA and 24Na5+ to TIGRESS. So we are poised
for source switchover to provide 24/26Mg pilot beams from the MWS.
Entry  Mon Oct 4 09:46:12 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for TIGRESS setup 
A 20Ne1+ beam from the MWS was established on Friday. Line tuning began Friday evening. A tune to the front of the SC LINAC was in place by Saturday.
Tuning through was delayed by SC tank conditioning.When
the LINAC is ready, tuning to TIGRESS will
Entry  Mon Oct 4 09:40:30 2010, Damien Gallop, , , OLIS Maintenance and Development completed 
The September Mini-Shutdown is now a memory. The few days available to OLIS were used for MCIS Development on 197Au. Productive. A 197Au34+ beam sat
on FC6 overnight. The program ended
Friday, at which point a 20Ne1+ beam from the MWS was established, and line tuning
Entry  Fri Sep 24 13:22:00 2010, Damien Gallop, , , OLIS Maintenance and Development 
Supernanogan on overnight, in the search for gold. A trace of 197Au34 observed this morning. Development continues.
A/q: 5.7941
FC6: ~500epA
Entry  Thu Sep 23 09:20:34 2010, Damien Gallop, , , 4He1+ for DRAGON Picture_1.pngPicture_1.pngPicture_2.pngPicture_3.png
DRAGON continues to take MWS beam.
Later... 14:00 EOB. Prepare for Mini-Shutdown.
Entry  Mon Sep 20 09:34:44 2010, Damien Gallop, , , 4He1+ for DRAGON 
MCIS Development finished Friday evening. OLIS switched to MWS operation and setup began for 4He1+ delivery to DRAGON. Beam handed over to experiment
last night.
Entry  Fri Sep 17 14:02:29 2010, Damien Gallop, , , MCIS Development Picture_3.pngPicture_5.pngPicture_2.pngAu25beam.pngAubeamNoSputter.png
Today's agenda: RF frequency scans and generally getting a feel for the new sputter source.
Mass scan plots in region of 197Au25+ attached below, taken with and without the sputter source on. Matlab post-processed pics to come shortly.
Entry  Thu Sep 16 17:06:22 2010, Damien Gallop, , , MCIS Development grab.yx5537.pngmcis2010sep16Au.png
A new sputter source was installed onto the Supernanogan. A wire of Au is installed in the source. Mass scans this morning with source at equipotential.
Source patched to MWS EE supply and biased to ~1kV tunable. That makes a significant improvement in intensity. Beam at FC6 is 197Au24+ presently.
Entry  Tue Sep 14 09:18:28 2010, Damien Gallop, , , MCIS Development 8x
The 16O3+ DRAGON run just finished. MCIS Development begins this morning for a few days. The goal is to install and characterize the new sputter ion
source.
Below are vacuum pics before and after closing MCIS:IV0. There was a bit of a spike during closing. All three turbos switched off. TP3 is down
Entry  Fri Sep 10 10:38:13 2010, Damien Gallop, , , 16O3+ for DRAGON grab.E24058.png
 
Entry  Fri Aug 13 09:27:49 2010, Damien Gallop, , , 4He1+ for SCC Development Picture_12.png
MWS is running nicely. SCC development continues. This is scheduled to end on this coming Tuesday morning. It will likely continue for a couple of days,
after which there would be a beam switch to 16O2+ from the MWS for TUDA-II setup.
Entry  Wed Aug 11 10:35:03 2010, Damien Gallop, , , 4He1+ for SCC Development Picture_1.png
Beam used into last evening, then idle overnight. Nice and stable. Maintenance Day for the cyclotron and ISAC.
Entry  Tue Aug 10 09:30:36 2010, Damien Gallop, , , 4He1+ for SCC Development Picture_2.png
Beam idle overnight, and grew nicely. Source tweaked up and throttled back a little while ago. SCC development expected to continue today.
Entry  Mon Aug 9 10:38:43 2010, Damien Gallop, , , 4He1+ Setup for SCC Development 
We have a request for changing over the source to 4He1+ operation
from the MWS.
Later... OLIS opened. Canister purged with N2 and pumped via IOS, then valved off and disconnected. ICR has restored a recent 4He1+ tune.
Entry  Mon Aug 9 09:09:36 2010, Damien Gallop, , , 35Cl2+ for DRAGON Picture_24.png35Cl2_Startup.png
Beam ran quietly over the weekend, with the anticipated intensity drop-off. Source gas canister at ~15"Hg and IOS at 3.3e-7 presently. Several DRAGON
energy changes were done as planned.
Later... at ~09:45 DRAGON is done.
Entry  Fri Aug 6 09:50:22 2010, Damien Gallop, , , 35Cl2+ setup for DRAGON 6x
First beam appearing on FC6 presently, after the source pumped overnight. Source gas valving set up earlier this morning.
Later... We have a whopping 5nA of 35Cl1+. We expect orders of magnitude more. Mass scans and investigation in progress.
Later... Another scan after some source gas changes. Much better. 35Cl+1 = 575nA 35Cl+2 = 3.5pnA with 1mm slits.
Entry  Thu Aug 5 18:56:48 2010, Damien Gallop, , , 35Cl2+ setup for DRAGON 
OLIS off Wednesday morning for source changeover from 16O3+ to 35Cl2+. We have elected to use the MWS for this run. Supernanogan is removed from OLIS
and parked at its service dock. Lots of leakchecking done on both sources. Both sources are under high vacuum presently and improving. MWS will be ready
to start in the morning.
Entry  Thu Aug 5 17:47:04 2010, Damien Gallop, , , 16O3+ for TIGRESS EOB Tuesday a.m. 16O3_for_TIGRESS.png
Delivery of 16O3+ for TIGRESS "buddy beam" purposes ended early Tuesday morning,
followed by CSB setup as an ion source Tuesday day. MWS behaved very nicely. Beam off Wednesday morning for switchover.
Entry  Tue Aug 3 09:31:30 2010, Damien Gallop, , , 16O3+ for TIGRESS Picture_9.png
Beam idle for most of the weekend. Some ion source ups and downs, in part due to a WFB setting on the edge. Tuning began last evening. Some funny business
overnight with apparently disappearing and returning beam.
Entry  Fri Jul 30 09:09:35 2010, Damien Gallop, , , 16O3+ for TIGRESS Picture_4.pngPicture_5.pngPicture_6.pngPicture_7.png
Supernanogan is online. Setup done last night. There is room for tweaking, but stable 3enA on FC6 of 16O3+ presently. We'll see if ICR has room for tweaking
before handover to users. Yes, we have clearance.
MCIS RF scan in progress.
Entry  Thu Jul 29 18:12:38 2010, Damien Gallop, , , 16O3+ Setup 6x
So... the long-awaited word to switch OLIS beams and sources finally came through... at 17:45.
Luverly. Anyway, we're on it. Basic idea: 4He1+/MWS -> 16O3+/MCIS. Users only care about A/q being as close to 72/13 as possible using standard beams.
Last moments of 4He beam shown below. MWS is running very nicely.
Entry  Thu Jul 29 15:31:21 2010, Damien Gallop, , , 4He1+ for TIGRESS 
Beam in use intermittently.
Entry  Wed Jul 28 09:23:57 2010, Damien Gallop, , , 4He1+ for TIGRESS Picture_1.png
Source switchover went quite well yesterday morning. About 6nA of beam on FC6. Beam idle overnight. Tuning has resumed now.
Entry  Tue Jul 27 08:55:49 2010, Damien Gallop, , , OLIS Maintenance Picture_4.pngPicture_5.pngPicture_6.png
Today we switch from 74Ge1+ to 4He1+, about as wide a switch as we've done at OLIS. We will use the MWS for the 4He.
Later... sources lit. First mass scan attached. Intensity is pretty low for now.
Later... MWS optimized better. Optimal He gas pressure is somewhere between zero and the leakthrough rate on the flow controller set at zero. Stripchart
Entry  Mon Jul 26 09:41:46 2010, Damien Gallop, , , 74Ge1+ to TITAN 
Beam is sitting on FC6 presently. Good source operation over the weekend. Some pics to come. RIB delivery to TITAN ended at 08:30 this morning. OLIS
is scheduled for a beam switch tomorrow morning.
Later... A power bump knocked us out
Entry  Fri Jul 23 13:00:04 2010, Damien Gallop, , , 74Ge1+ to TITAN Picture_4.pngPicture_3.png
Beam remained on FC6 overnight. Beam was used for a tune check this morning. At noon today beam was switched to 4He.
Later... Outcome of 4He development with Supernanogan: beam comes with other isotopes. e.g. 12C3+ and 16O4+. Verdict: 4He1+ beam is better produced
with the MWS.
Entry  Thu Jul 22 09:25:21 2010, Damien Gallop, , , 74Ge1+ to TITAN Picture_3.png
The Supernanogan is producing 74Ge using the heater source, a first for the Supernanogan.
Development done over the last couple of days and completed
yesterday. Tuning using mass 76 (76Ge or 76Se?)
Entry  Tue Jul 20 09:38:45 2010, Damien Gallop, , , OLIS Maintenance Picture_3.png
Our work permit to leakcheck the Supernanogan and IOS was signed this morning. The source is off presently, and work is underway. The 12C2+ beam was
not used overnight.
Entry  Mon Jul 19 10:56:53 2010, Damien Gallop, , , 12C2+ for TIGRESS Picture_2.png
Beam from the Supernanogan remains on standby for TIGRESS pilot beam. There were a couple of source trips over the weekend, at least one a consequence
of a power bump that took out a few other things too.
We have had a couple of pending work permits in the queue for a while. One is for germanium beam development,
Entry  Fri Jul 16 10:22:35 2010, Damien Gallop, , , 12C2+ for TIGRESS Picture_1.png
Tuning to TIGRESS is continuing. There is a full expectation that they will take RIB over the weekend.
As it stands, the beam schedule shows switchover from TIGRESS to TITAN on Sunday evening. For a couple of reasons, it would make sense to move
that time into Monday or so.
Entry  Wed Jul 14 09:23:19 2010, Damien Gallop, , , 12C2+ for TIGRESS Picture_1.png
OLIS is set up for 12C2+ delivery, with about 13enA on FC6 from the Supernanogan source presently. Beam was reasonably stable overnight, and should condition
out better over time as well. Initial tuning into ISAC-I is planned to begin this morning.
Entry  Tue Jul 13 18:33:04 2010, Damien Gallop, , , OLIS Maintenance and Development 
A source switchover day was negotiated, with a goal to provide 12C2+ beam. As a practical matter, it's been an OLIS Maintenance Day, at least for the
morning. Controls installed a cable to provide remote reset capability for the OLIS Enable interlock panel. However, it did not perform as expected first
time, so Controls has elected to pursue this another time. Meanwhile, the remote cable is at the rear of the OLIS Enable panel, ready to be connected next
Entry  Mon Jul 12 10:55:14 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning Picture_1.png
Beam used sporadically over the weekend. Note temperature response in beam. A power bump occurred at about 10:00, knocking out OLIS. It was challenging
to come back to where it was before.
Entry  Fri Jul 9 10:00:03 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning 8x
Source drifted overnight. Operators made a slight correction to silence an alarm. I have tweaked this up. Shown below are before and after. Marco believes
present beam is unstable. I will see if I can tweak up the intensity, and perhaps that will satisfy all requirements.
Later... ~13:00 this is just about as good as it gets. Stripchart of the last couple of hours plus current excellent source parameters appended
Entry  Thu Jul 8 09:38:36 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning Picture_5.png
Beam idle overnight. Source conditioned and changed a bit. Slight tweaking required to bring it back to stable.
Entry  Wed Jul 7 15:21:36 2010, Damien Gallop, , , 16O1+ for SCC Commissioning 
A 16O1+ beam from the MWS is being used for SCC development and commissioning by agreement. Some sideshows getting there.
Later... At approximately 13:15, some event, a bias spark, it appears, took out a number of devices, most of which IOPS reset. The FUG blew a fuse
on startup. Replacement OK. However, there remains an interlock light on the IOS:BIAS panel with no apparently unsatisfied interlocks showing. Controls
Entry  Tue Jul 6 19:10:33 2010, Damien Gallop, , , OLIS Maintenance grab.CK3013.png
Source pulled down for Mg removal and cleanup. Done. Supernanogan refurbishing of MCIS optics complete, plus a comple of other items. Opened joints leackchecked
and okay. MCISIOC was in a partial state, where devices worked but not interlocks. It turns out that Controls knows about this. Msg to investigate in the
morning. Meanwhile, MWS is up with a 16O1+ beam on FC6 presently. FYI, the vacuum pumpdown curve during leakcheck and startup operations.
Entry  Tue Jul 6 08:57:33 2010, Damien Gallop, , , 26Mg6+ for TIGRESS EOB Picture_2.pngPicture_3.pngPicture_4.png
Photo-finish for TIGRESS this morning, apart from a cavity trip
at around 6:00 a.m.. The MWS is running very well. Some EOB activities underway presently.
Plan for today: MWS pulldown for Mg removal and cleanup. If feasible, we will install the Supernanogan into the OLIS cage as well.
Entry  Mon Jul 5 11:58:49 2010, Damien Gallop, , , 26Mg6+ for TIGRESS Picture_1.png
Beam was switched from 24Mg5+ to 26Mg6+ on Canada
Day. Also, the source blinked out on Saturday. Remote restart okay. Source is running well.
Supernanogan maintenance continues. MCIS optics module was reassembled last week and installed this morning. Also a section of wveguide was replaced
Entry  Wed Jun 30 09:11:25 2010, Damien Gallop, , , 24Mg5+ to TIGRESS Picture_2.pngPicture_3.png
Delivery / standby continues.
Entry  Tue Jun 29 09:16:33 2010, Damien Gallop, , , 24Mg5+ to TIGRESS 6x
Delivery to TIGRESS has begun. Beam from the source looks perfect. Looks  like happy times for them. The plan is to eventually deliver 24Na5+ via the
CSB. Maintenance Day for the radioactive lines is in progress now.
Later... This is about as good as it gets for magnesium beams from the MWS. Attached are screen shots of the source setup.
Entry  Mon Jun 28 09:19:16 2010, Damien Gallop, , , 24Mg5+ to TIGRESS Picture_1.png
Delivery looks like it was pretty smooth over the weekend. TIGRESS expects to receive 24Na from ITW via the CSB this week. Yield goes today.
Entry  Thu Jun 24 11:52:34 2010, Damien Gallop, , , 24Mg5+ to TIGRESS setup Picture_2.png
Tuning into ISAC-II was done yesterday, and continues today. The source was idle overnight. There were a couple of magnesium hiccups. Beam is looking
fine right now.
Entry  Wed Jun 23 09:17:34 2010, Damien Gallop, , , 24Mg5+ to TIGRESS setup Picture_1.pngPicture_2.pngPicture_3.pngPicture_1.png
Mass change yesterday morning from 26Mg1+ to 24Mg1+ from the MWS. It was tough to get stable beam from the source, and there are signs of Mg plating
out on stuff. Keerthi was here last evening and again overnight to open the source and clean it up. Good job.
Later... There were a couple of power bumps over the lunch hour. One took out OLIS, the other didn't. Yes, the IOS Enable panel had to get a local
Entry  Tue Jun 22 08:42:33 2010, Damien Gallop, , , 26Mg6+ for TUDA-II Picture_3.png
Beam was redirected to TIGRESS yesterday. RIB delivery to TIDA-II was rendered impossible due to a failure in the target or module. We have a verbal
request in place now to change mass from 26Mg1+ to 24Mg1+. Attached is a plot of beam overnight on FC6 prior to changeover.
Entry  Mon Jun 21 09:20:30 2010, Damien Gallop, , , 26Mg6+ for TUDA-II Picture_1.pnggrab.oS5646.png
Beam waiting quietly on FC6. There was a power
bump on Friday just after noon that tripped the world. Keerthi restarted OLIS. Beam never really came back to its former glory. We'll see if there
might be an opportunity to touch it up.
Entry  Thu Jun 17 09:21:56 2010, Damien Gallop, , , 26Mg6+ for TUDA-II Picture_1.png
TUDA-II began taking beam around midnight
last night. Beam on FC6 for a good part of the night. Steady as she goes.
Entry  Wed Jun 16 10:12:58 2010, Damien Gallop, , , 26Mg6+ for TUDA-II Picture_1.png
Beam idle overnight. Beam is being used as a pilot beam for this run. Source was knocked off by a power
bump on Monday evening. Signs are that the root cause is the same as last time, loss of 24V to the IOS interlock panel.
Entry  Mon Jun 14 09:44:06 2010, Damien Gallop, , , 26Mg6+ for TUDA-II Picture_4.png
On Saturday we opened the MWS and set it up for Mg operation. Everything went well. We are using the pair of half-moon Mg metal plates together with
a thin Mg foil liner inside a bottomless quartz liner. Tune setup for HEBT/SEBT operation set up yesterday. 26Mg is selected. MCOL3A/B tuning for true
centre is in progress right now while there is opportunity.
Entry  Sat Jun 12 11:23:40 2010, Damien Gallop, , , 26Mg6+ to TUDA-II source setup grab.x14118.png
After EOB activities from 15N4+ run that ended this morning, we have begun preparations to switch over the ion sources. Turbos off just after 11:00.
We have Mg source material ready. We will be using the MWS ion source. Due to the requirement to run the source at 53kV, we will also remove the Supernanogan
cart from the cage as a sparking precaution.
Entry  Sat Jun 12 10:20:14 2010, Damien Gallop, , , 15N4+ to TIGRESS done 13x
Delivery to TIGRESS ended this morning as scheduled. ICR took nice emittance
scans and is completing a target snapshot now. Canister still at -22"Hg and MCIS at 7.3e-8 Torr.
Chance to snap some wirescans. Attached.
Entry  Fri Jun 11 09:21:24 2010, Damien Gallop, , , 15N4+ to TIGRESS Picture_1.png
Delivery of 15N4+ to TIGRESS continues. Source gas canister is still at ~-22"Hg, and MCIS pressure is 7.2e-8 Torr. ICR reported intensity drops
a couple of times this morning. The attached Stripchart suggests beam from the source is down to about a third from status quo. We will look into it now.
Entry  Thu Jun 10 09:17:42 2010, Damien Gallop, , , 15N4+ to TIGRESS Picture_1.pngPicture_2.pngPicture_3.png
Delivery to TIGRESS began yesterday
or so. ICR reported beam intensity drops overnight. I'll look at it presently. Meanwhile, canister pressure is still ~-22"Hg and MCIS pressure is
7.09e-8 Torr.
Entry  Wed Jun 9 10:07:33 2010, Damien Gallop, , , 15N4+ to TIGRESS Picture_7.png
Setup into ISAC-II began last night. Tuning is in progress now. Beam on FC6 overnight. Canister pressure is -22"Hg and MCIS pressure=7.1e-8 Torr.
Pressure showed correlation with temperature. It is overcast today and cool, suggesting a fairly flat response today.
Entry  Tue Jun 8 09:27:54 2010, Damien Gallop, , , 15N4+ to TIGRESS Picture_4.pngPicture_5.png
User tuning began Sunday night. Beam physics expert chose to retire the IOS:Q1 defeat, as he did not know until yesterday that it existed. He discovered
it after attempting to retune yesterday around noon from scratch and making a mess, notwithstanding Keerthi's clear instruction to leave
it alone. He also does not know that Rick developed a tune for this, which provides cleaner transmission than the "book" tune. Pity. Presently
Entry  Mon Jun 7 10:36:14 2010, Damien Gallop, , , 15N setup over the weekend Picture_2.png
Keerthi set up the Supernanogan for 15N operation and destined for TIGRESS, using two source gas options: a miniature bottle of enriched 15N2 and a canister
with a charge of research-grade 14N2. The canister is similar to the one we used for the 33S run to DRAGON, which finished Saturday morning. Canister is
at -22"Hg and MCIS at 7.27e-8 Torr. A couple of beam stability tests were conducted at 15N4+ and 15N6+. Bob can choose which one he prefers to use.
Entry  Fri Jun 4 09:30:48 2010, Damien Gallop, , , 33S to DRAGON Picture_2.png
Delivery of 33S6+ continues to DRAGON for the final day. Some online tuning of the line overnight. Source gas canister pressure remains at ~-20"Hg,
and MCIS pressure is at 7.1e-8 Torr.
Entry  Thu Jun 3 09:29:11 2010, Damien Gallop, , , 33S to DRAGON Picture_1.png
33S6+ delivery to DRAGON continues until Saturday morning. All the signs are that beam is excellent. Source gas canister is still at ~-20"Hg, and
MCIS vacuum is at 7.0e-8 Torr.
Entry  Wed Jun 2 09:19:04 2010, Damien Gallop, , , 33S to DRAGON 
33S6+ delivery to DRAGON continues. It is Maintenance Day for everybody else today. Source gas canister pressure = -20"Hg. MCIS pressure = 7.7e-8
Torr.
Entry  Tue Jun 1 09:12:39 2010, Damien Gallop, , , 33S to DRAGON Picture_2.png
33S6+ delivery to DRAGON continues. Looks like there was an RF tweak overnight. Source gas canister still at ~-20"Hg. MCIS vacuum at 7.4e-8 Torr.
Entry  Mon May 31 09:18:39 2010, Damien Gallop, , , 33S to DRAGON Picture_2.png
Delivery of 33S6+ to DRAGON continues. A couple of RF tweaks done over the weekend. Source gas canister pressure at -20"Hg. MCIS pressure at 7.3e-8
Torr. At this rate, we could deliver 33S until approximately forever.
Entry  Fri May 28 11:02:59 2010, Damien Gallop, , , 33S to DRAGON Picture_1.png
Beam tuning in progress. Source gas canister at -20"Hg. MCIS pressure at 7.62e-8 Torr.
Entry  Thu May 27 09:11:10 2010, Damien Gallop, , , 33S Development and Handover Picture_2.png
33S on FC6 overnight. Preparing to send beam to DRAGON
now, and confirm isotope.
Source gas pressure gauge on canister = -20"Hg. MCIS pressure = 7.8e-8 Torr.
Entry  Wed May 26 18:16:10 2010, Damien Gallop, , , 33S Development grab.Cm6004.png
Some 3enA of beam on FC6 presently. Let it sit.
Entry  Tue May 25 22:02:41 2010, Keerthi Jayamanna, , , 33S spectrum 
33S spectrum is saved as 33S_spectrum.dat 
Entry  Tue May 25 11:58:02 2010, Keerthi Jayamanna, , , 33S dev 
after 24 hours background spectrum saved as "BackgroungNo33S003.dat"
RF Amplitude :7.767 , RFoutput power= 5W, Output power (dB)=36.4
Entry  Tue May 25 11:28:00 2010, Keerthi Jayamanna, , , 33D dev 
after 24 hours background spectrum saved as "BackgroungNo33S002.dat"
RF Amplitude :1.553 , RFoutput power= 0, Output power (dB)=0  
Entry  Tue May 25 00:19:18 2010, Keerthi Jayamanna, , , 33S 
 
Finally got something going. YCB1 short to the ground. YCB common plate connected to YCB1 power supply. We were lucky.
Polarity was right. Ran the source with no 33S.
Saved file as “backgroundNo33S.dat” No optics set yet.
Entry  Mon May 24 22:42:51 2010, Keerthi Jayamanna, , , 33S development Picture_1.png
Tried to see the background before 33S installation. Found few problems: MCIS:YCB1 does not hold more than
58V.
Very difficult to transport the beam without YCB1. Need to find a solution. Open and fix it is not
Entry  Wed May 19 09:55:51 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for TIGRESS Picture_6.png
ISAC-I tuning done yesterday. TBC today into ISAC-II. Beam very nice overnight.
Entry  Tue May 18 09:15:16 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for TIGRESS setup 8x
Prepare to switch beam from 22Ne2+ to 20Ne1+. Skimmers from 22Ne2+ run shown below. Table of tune options below. We will be using the Rick Tune.


    
        
            Device
            Present Tune
            Scaled
Entry  Tue May 18 09:03:32 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 EOB Picture_6.pngPicture_7.pngPicture_8.png
EOB for SEBT1 run at 08:30, taking 11Li from ITE and 22Ne2+ from OLIS when needed. Attempted emittance scans last evening, but no data showed, and no
more time to investigate. So be it. Another time.
Entry  Mon May 17 09:09:50 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 Picture_6.png
Last day of this pilot beam to TUDA-II. Expect a beam switch tomorrow for sake of TIGRESS.
Attached is Stripchart of weekend beam operation. Pretty nice indeed. Top trace (red) is Q3 skimmer, representative of total beam out of the source 
Blue trace is 22Ne2+ on FC6 with magnet field stabilization program active. Brown trace is NA-LCW temperature as measured at exit of Supernanogan plasma
Entry  Fri May 14 08:50:56 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 Picture_5.png
MWS continues to provide 22Ne2+ for pilot beam use. Beam quietly sitting on FC6. Stripchart attached. Also, Supernanogan plasma is on at low RF power
for conditioning.
Entry  Thu May 13 09:25:38 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 Picture_1.pngPicture_2.png
Beam continues to be reserved for E1147 pilot beam use. Beam was nice and stable overnight, as expected. Beam (blue) followed source (red), independently
of ambient temperature, roughly reflected in the nearby Supernanogan plasma chamber temperature (maroon).
Later... at 10:14 today there was a sitewide power bump due to an HPL test. It tripped the cyclotron and one isolated ISAC ion gauge. The ICR operators
Entry  Wed May 12 13:40:01 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 Picture_2.pngPicture_1.png
Back to pilot beam status as of around 18:00 last night. A couple of sideshows through the evening. ICR made an elog entry about the IOS:MB field stability
program here. But the information shown
is inconclusive. As noted in a work permit, Magstab is in fact using our
Entry  Tue May 11 08:55:41 2010, Damien Gallop, , , Supernanogan development grab.tg1846.pnggrab.bE1993.pnggrab.ed2041.pnggrab.or2050.png
Leak checking on the Supernanogan continues today. We are preparing for an up-coming 33S run, for which we want "perfect" vacuum. We're close.
Later... MCIS backing line is now running on leak detector only. Calibration in progress... Done.
There was a short MCIS vacuum excursion at ~09:15. There were two similar ones overnight. Probable cause: sealant outgassing.
Entry  Mon May 10 16:42:55 2010, Damien Gallop, , , Supernanogan development 
By agreement, the source came down this morning for continuing Supernanogan development. Main event: leak detecting.
Later... Robert and Tim lead leak detectors. Synopsis: A minute leak at waveguide flange on plasma chamber. We decided to seal it with a drop of
vacuum sealant. Worked like a jet. Once Supernanogan beams are done for this beam schedule, we will remove the waveguide and re-machine and weld the flange.
Entry  Mon May 10 09:39:34 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 Picture_1.png
Supernanogan development, mainly for the sake of the upcoming 33S run, took place for a little while on Friday. It was expected to go through tomorrow
(Tuesday), but we got the call for beam on Friday evening just before the Canucks game started. So it's up again. The beam was used for a while on Sunday
to check beam energy.
Entry  Fri May 7 19:10:05 2010, Keerthi Jayamanna, Routine, General, OLIS status 
MW source is back and running.
A new vacuum chamber is added to the Supernanogan RF block.
SO2 is not filled in yet.
Entry  Fri May 7 12:29:41 2010, Keerthi Jayamanna, , , Supernanogan development 
Supernanogan development for 33S started. All MW and MW and MCIS power sypplies are off.
Gas for microwave source also closed from hand valve
Later... separator field stability development. Local Hall probe is online. Let it cook.
Entry  Thu May 6 14:33:07 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 Picture_1.png
Beam from MWS remains quietly sitting on FC6, on standby for pilot beam use to SEBT1. The cyclotron is still down with cryogenerator issues. Latest prediction
is first protons this evening.
Entry  Wed May 5 09:46:40 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 
Beam on standby for pilot beam. Cyclotron is still down with vacuum troubles since ~03:00, so no RIB to ISAC.
Entry  Tue May 4 14:19:18 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 
Beam from MWS continues for pilot beam use into SEBT1. There are cyclotron issues with cryogenics, so 11Li delivery from ITE is suspended temporarily.
Later... we purchased a small UPS for the MCISRFIOC server. It arrived yesterday. After overnight charging, we installed it today. This is in response
to the hardware failure a couple of weeks ago.
Entry  Mon May 3 18:12:12 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 
Beam was switched on Friday morning from 16O1+ to 22Ne2+. This time it's a pilot beam for a 11Li experiment.
Entry  Fri Apr 30 13:02:17 2010, Damien Gallop, , , 22Ne2+ at 22.44keV for SEBT1 
Mid-morning the source was switched over from 16O1+ to 22Ne2+ operation for a new experiment. OLIS will be used as the pilot beam during this 11Li run
to SEBT1/TUDA-II.
Entry  Fri Apr 30 12:58:21 2010, Damien Gallop, , , 16O1+ at 32.64keV to SEBT2 grab.s30283.pnggrab.Y30291.pnggrab.z30299.png
Delivery to S1151 went quietly overnight for their last few hours. The run ended at ~08:30 as scheduled. Marco and ICR did some EOB checks. Also, a quick
EOB emittance scan is attached. There were problems
with the beam tune save files, since resolved. Among the last ones are 100430_0918.snapiossebt2 (missing SEBT optics) and 100429_2023.snapiossebt2. 
Entry  Thu Apr 29 09:11:27 2010, Damien Gallop, , , 16O1+ at 32.64keV to SEBT2 Picture_5.png
Another quiet night of beam to S1151.
Entry  Wed Apr 28 10:08:05 2010, Damien Gallop, , , 16O1+ at 32.64keV to SEBT2 Picture_4.png
Beam delivery continued nicely through the night.
Yesterday Controls repaired and reinstalled the MCISRFIOC computer. It is working well. More details to come.
Entry  Tue Apr 27 09:04:13 2010, Damien Gallop, , , 16O1+ at 32.64keV to SEBT2 Picture_1.pngPicture_3.pnggrab.NQ9764.png
Nominal beam operation to SEBT2 overnight. A chart of beam over the last few days is attached. There is a step change in the separator field right around
midnight. Although the archive does not show it, in fact this was adjusted at 23:54 last night.
 
Entry  Mon Apr 26 10:58:46 2010, Damien Gallop, , , 16O1+ at 32.64keV to SEBT2 Picture_1.png
Our first experiment of the year started right around midnight last night, after extensive tuning. As I understand it, S1151
will confirm the age of the universe. The MWS source performed flawlessly over the weekend.
Entry  Fri Apr 23 10:18:32 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning Picture_4.png
Marco and experimenters are busy at it, tuning the DTL. Regarding the source, he is "happy as always!" Well, that makes at least two of us.
After this segment of tuning is complete, then he will move on to setup for the upcoming S1151 run at SEBT2 on Sunday.
Entry  Thu Apr 22 14:57:25 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning 
Accelerator development continued this morning. Beam from source was reported to be "good". ICR showed me their long-term Stripchart
of our beam. There is a clear daily correlation of beam intensity with weather. Interesting. Beam idle on FC6 since ~lunchtime. I took the opportunity
to do a little magstab development. The server now runs Konstantin's ser2net patch which fixes
Entry  Wed Apr 21 15:30:09 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning Picture_8.png
Beam up as of last evening. Controls performed some network upgrades today, which impacted beam operations. One glitch on our side: OLIS:MB drive bit
was lost. Fault report. Otherwise, all's
right with the world, and Sophia has resumed accelerator development.
Entry  Tue Apr 20 09:02:18 2010, Damien Gallop, , , OLIS Maintenance Picture_3.pngPicture_4.pngPicture_5.png
Maintenance Day for OLIS started late yesterday afternoon. Source up at end of the day. See attached Stripchart and in particular how the source (blue
trace is beam at FC6) came back to its nominal state within a reasonable time. Maintenance TBC after lunch.
Later... Hardware maintenance complete. Source HV and source gas tests followed by source startup around 16:30. Next up: magstab development.
Entry  Mon Apr 19 17:12:55 2010, Damien Gallop, , , OLIS Maintenance 
Just in: an active work permit for OLIS maintenance. Underway through tomorrow (Tuesday) evening.
Save: 100416_2339.snapiosvault
Later... done for today. Source is on for the night.
Entry  Mon Apr 19 10:11:17 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning Picture_1.pnggrab.a19570.png
Development on Friday; idle over the weekend. Stripchart attached.
Meanwhile, there was a power bump at around 09:30, and the source went out. Restarted OK.
Entry  Fri Apr 16 09:26:01 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning grab.Ft9922.png
Beam development through accelerators continues today. Beam was rock-stable overnight.
Entry  Thu Apr 15 09:39:11 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning 
Yesterday's RF troubles in ISAC-I are reportedly solved. Beam development is expected to resume this morning.
Entry  Wed Apr 14 17:28:32 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning 
Beam reserved for continuing accelerator development, but there are some ISAC-I RF phase troubles. However, maintenance was not permitted today... until
just now. Too late for today.
Entry  Tue Apr 13 10:20:27 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning Picture_3.png
Accelerator commissioning has resumed for the day. Beam was nice and stable overnight. See attached Stripchart.
Entry  Mon Apr 12 11:53:22 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning Picture_1.pngPicture_2.png
Beam was used last week for DRAGON commissioning. Successful run, completed yesterday, as reported by Colin this morning.
Milestone: First coasting beam through
new SCC on Thursday, 8-Apr-2010 at ~20:00, using 16O(1+)4+ at 1.5MeV/u from MWS.
Entry  Thu Apr 1 09:23:08 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning Picture_1.png
Beam idle overnight. Another night of super-stable beam. If no users today, then we may take it for MRO.
Later... Check out magstab program while we have quiet time. Test outcomes when serial link is opened. Purpose: Improve fault tolerance. Done.
Sophia will take the beam shortly.
Entry  Wed Mar 31 09:43:30 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning Picture_13.png
Beam set up for accelerator commissioning. Sophia took beam yesterday. Beam idle overnight. Stripchart of overnight performance attached.
Entry  Tue Mar 30 10:27:09 2010, Damien Gallop, , , 16O1+ at 32.64keV for accelerator commissioning Picture_12.png
16O1+ beam requested yesterday. Source switched over and beam ready by evening. Nice overnight Stripchart, attached. Sophia has the beam now.
Entry  Mon Mar 29 12:15:00 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for accelerator commissioning 
OLIS sprung a water leak last night. Problem was sparking through a coiled  cooling line. I replaced the pair of cooling lines and rerouted them
somewhat. Source is up again now.
Entry  Fri Mar 26 09:31:04 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for accelerator commissioning Picture_10.png
Beam idling overnight. Yesterday ICR called me regarding an IOSIOC reboot and consequent fallout. In short, it turned off IOS:MB. Not good. While the
fix was easy enough, it took time to find it, which would translate to downtime during regular delivery. A lesson learned. I just noticed now that the
magnet stability program was out of range and obviously had been since the IOC reboot. I reset the power supply and field. This procedure will need to
Entry  Thu Mar 25 12:43:16 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for accelerator commissioning Picture_8.png
Beam stable as a rock overnight. Pity we have no-one using it at the moment! Stripchart attached.
Entry  Wed Mar 24 11:42:32 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for accelerator commissioning Picture_9.png
Beam is on standby. Target snapshot
in IOPS elog.  Over the last little while...
* IOS:IG1 repaired last evening. IOS vented to Ar, flowing for duration of repair. Standard Varian filament repair kit used with Dimo's instructions.
Entry  Fri Mar 19 09:00:21 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for accelerator commissioning Picture_5.png
MWS is running well. Tune save: 100319_0901.snapiosdragon with beam observed to Prague magnet. Stripchart of last 24h attached.
Entry  Wed Mar 17 09:25:27 2010, Damien Gallop, , , 20Ne1+ at 40.8keV for accelerator commissioning Picture_2.pngPicture_3.pngPicture_4.png
20Ne1+ set up from the MWS and handed over to Sophia & Marco for accelerator recommissioning. Strip to 5+ at M:5. First day of beam. Happy St. Patrick's
Day.
Later... a Stripchart of beam today: baby-blue trace is FC6. Also, here are screenshots of the source.
Entry  Fri Mar 12 11:35:34 2010, Keerthi, , , Cusp water cooling 
Cusp source water cooling (#4)  interlick does not work.
Entry  Fri Mar 12 11:33:09 2010, Keerthi, , , IOS:IG! 
IOS:IG1 is faulty. Need to replac it during next earliest window.
Entry  Thu Mar 11 23:02:18 2010, Keerthi, , , OLIS status after shutdown 
Microwave source is up and running.
Supernanogan: grounding rod is stuck, RF generator does not clear the interlocks (controls?)
LEBT: FC3 air leak, in is out, out is in
Entry  Fri Feb 19 17:54:40 2010, Damien Gallop, , , OLIS Shutdown in progress DSCN7351.JPGDSCN7355.JPG
Partial disassembly of DB1 optics today. Shielding of insulators is definitely working and indicated for unshielded insulators. Discussion of possibilities
in progress. Wiring looks good, but one Kapton wire snapped at the connector upon disassembly (no force required).
Entry  Wed Feb 17 18:28:33 2010, Damien Gallop, , , OLIS Shutdown in progress 
More materials prepared for optics refit.
Entry  Tue Feb 16 16:04:18 2010, Damien Gallop, , , OLIS Shutdown in progress 
Preparations for rewiring the DB1/3 optics have begun. Sgan gas manifold work is in progress. Note: IOS:MP1 is scheduled for refit service shortly. We
received major rebuild kits a few days ago, one to replace the kit used when the previous MP1 failed last fall. It is not likely this pump requires it;
only the standard seal kit.
Entry  Fri Feb 12 14:42:06 2010, Damien Gallop, , , OLIS Shutdown in progress 8x
Supernanogan cart removed from Faraday cage to dock today. Some beam safety tests on FC6 in progress presently. FC3 was already removed for replacement.
Optics Photos: Lots taken; selected ones here as time permits.
3-Way Switch (DSCN7285.jpg & DSCN7286.jpg) looks pretty good. There is some discoloration on a downstream insulator, but far from worrisome.
Entry  Wed Feb 10 17:18:24 2010, Damien Gallop, , , OLIS Shutdown in progress 
OLIS Shutdown has been in progress for a week. IOS is vented, was swiped clean and opened. DB3 was craned out, a precision job. Note to whover reinstalls
this box: Request Lu Sun to do it. He knows exactly how to tension the ropes so that the seals are not at risk of damage. Upstream optics
in DB1 were also removed in the standard three sections. No problem removing them. Photos and commentary to follow. Bellows downstream and ahead of separator
Entry  Wed Feb 3 16:30:02 2010, Damien Gallop, , , OLIS Shutdown began today 
We prepared stuff last night. This morning we vented IOS to argon, then swiped. Clean. Lu and Ajit craned out DB3 for us. Nice job, as usual. We will
remove it and its neighbors to the ISIS Lab for refurbishing. OLIS Shutdown is scheduled to go until March 10th.
Entry  Tue Feb 2 10:06:41 2010, Damien Gallop, , , Supernanogan development wind-up 9x
We ran 32S5+ overnight. Keerthi has been working with the new surface source oven for the last couple of weeks. His results to come. Meanwhile, here
are a stripchart of overnight beam plus a few panels after my tweaking. Slits are at 5mm position.
Observations:
Entry  Fri Jan 15 15:30:02 2010, keerthi, , , Supernanogan oven start up 
Voltage              Current             MCIC:IG1
0                            0                
      7.35e-8
Entry  Thu Jan 14 09:57:05 2010, Damien Gallop, , , 20Ne1+ beam from MWS for 8pi diagnosis 9x
Beam is on for 8pi diagnosis by special request.
We set up beam in IOS yesterday. However, beam blinked out last evening, likely due to insufficient source gas pressure. Source restarted with
just a little difficulty this morning. ICR adjusted downstream IOS optics to match into next section. Looking good, and they are tuning now, ~10:00 a.m.
Entry  Wed Jan 13 18:16:22 2010, Damien Gallop, , , OLIS development with MWS at 28keV 6x
We will be delivering a 28keV beam to the tuning boys tomorrow for further diagnosis of the 8pi line. In anticipation, I restarted the MWS with 20Ne1+
beam. With slits out, there are around 2uA on FC6. Emittance scan of current tune below.
Same tune again with slits in a 1mm, emittance scan attached.
Entry  Mon Jan 11 17:46:31 2010, Damien Gallop, , , OLIS development for 4He2+ beam loose ends grab.r14041.pnggrab.Q14048.pnggrab.h14058.png
OLIS was shut down over Christmas. We did a "soft start" of the MWS last Tuesday, after refurbishing and installation before Christmas. Worked
like a jet.
Today: 4He2+ beam development + emittance scans. Here is the best so far.
Entry  Mon Jan 11 17:40:07 2010, Damien Gallop, , , Happy New Year! 
Welcome to 2010. Shutdown is underway across the site, while beam development is going on at OLIS.
Entry  Thu Dec 24 10:13:00 2009, Damien Gallop, , , OLIS development 20Ne1+ from MWS Picture_5.png
The MWS stayed up flawlessly overnight. Beam grew from about 2µA to over 5µA this morning. Was it the pre-conditioning of the RF generator?
We will look at the beam for a bit now, then shut it down for Christmas.
Entry  Wed Dec 23 11:09:37 2009, Damien Gallop, , , OLIS development 7x
So... lots has happened.
* Supernanogan *
Heater components installed in plasma chamber. Cart reinstalled into Faraday cage. Scroll pump rebuilt! (Thanks, Dan and Edi!) Pumping started
Entry  Mon Dec 21 10:22:33 2009, Damien Gallop, , , OLIS development for CUSP source - installation cont'd grab.I28800.pngPicture_8.png
Keerthi and Marco achieved visible 4He2+ through the RFQ on Friday (or so). Mass spec attached. Development continues today.
Update: First visible A/q=2 beam through the RFQ at about 14:00 on Friday, December 18th, seen on M:5, an historic milestone for ISAC. Beam later
observed on MEBT spectrometer around 16:00.
Entry  Fri Dec 18 13:14:01 2009, Damien Gallop, , , OLIS development for CUSP source continued  9x
Yesterday: Busy! Source filment changed last night. Source pumped overnight. First start this morning.
Today: Busy! Nutshell: A/q=2 passed to Marco for isotope verification at MEBT.
Later ~16:00 Beam on MEBT:FC5, an historic first for achieving A/q = 2 through RFQ. 1.6enA of (likely) 4He2+. Tuning to FC7 continues.
Entry  Wed Dec 16 14:07:37 2009, Damien Gallop, , , OLIS development for CUSP source continued  grab.n10208.pnggrab.o10214.pnggrab.G10224.pnggrab.T10230.png
Today we vary source gas pressure.
Later... Several iterations of pressure, tuning and standing on our heads. Representative emittance scans attached below. TBC tomorrow.
Entry  Tue Dec 15 17:50:38 2009, Damien Gallop, , , OLIS development for CUSP source continued  
Four larger apertures were installed yesterday. This morning we fired up the modified source. It lit immediately. Plenty of beam. Development at 28kV,
then scaled to 15kV. Beam intensities and ratios did not scale. Thesis: Space charge effects are too much for 15kV. Also, I3 accel-decel lens p/s needs
work. We added a ballast to it today; p/s in tomorrow, then retest.
Entry  Mon Dec 14 10:01:52 2009, Damien Gallop, , , OLIS development for CUSP source continued 
Development over the weekend. Results to come. Restart source now and let it warm up. 4He2+ on FC6. Plasma at zero, to duplicate weekend settings. Arc
at 150V. FC6 ~=150enA and settling down presently, IG1 = 2e-7 Torr.
Later ~10:00: FC6 ~500enA. Mass scans next.
Entry  Fri Dec 11 18:03:30 2009, Damien Gallop, , , OLIS development for CUSP source continued  
Today we swapped power supplies between the arc and plasma electrode. This gives us a higher voltage range on the arc, at the possible expense of current
limiting. We plan an extended round of development in this mode.
Entry  Thu Dec 10 08:59:05 2009, Damien Gallop, , , OLIS development for CUSP source continued  Picture_12.pngPicture_13.png
Source stayed up quietly overnight. Current dropped off gradually. I will tweak things shortly.
Beam tweaked up to 3eµA. Pressure is ~5e-7 Torr. Plan for today will include a rework of the arc and plasma power supply wiring to achieve
higher V on arc and opposite polarity on plasma.
Entry  Wed Dec 9 10:24:45 2009, Damien Gallop, , , OLIS development for CUSP source continued grab.k18688.pngPicture_5.pngPicture_6.pngPicture_7.pngPicture_8.png
CUSP source was off for the night, following Keerthi's development. He had increased the current on FC6 and the arc current substantially. More later.
Meanwhile, restart source and let it condition for a bit.
Later ~14:00 we have 200enA on FC6. Source gas is shut off presently. Time for some mass scans. Strategy: Identical mass scans without and with
Entry  Tue Dec 8 12:40:17 2009, Damien Gallop, , , OLIS development for CUSP source continued grab.M11379.pnggrab.S11386.png
Fuse for FUG power supply obtained and installed. Source is up and warming up. ~100enA on FC6.
Later ~14:00: Tweak things up. We now have a more stable 380enA on FC6. IOS:IG1 = 7e-7 Torr.
Later ~15:15: Adjust source gas metering valve "just a little"... and effectively vent the tank. This needs work. Recover, restart source.
Entry  Mon Dec 7 09:48:24 2009, Damien Gallop, , , OLIS development for CUSP source continued Picture_4.png
The OLIS cage was open over the weekend. IOS pressure is in the 4e-7 range, with source gas manifold closed and external helium bottle slightly opened
through the metering valve. Today's game plan is being discussed presently.
Later ~11:00: Restart source. 50enA of A/q=2 at FC6. We had planned to restart with background source gas, but pressure is too low in gas lines,
Entry  Fri Dec 4 18:15:19 2009, Damien Gallop, , , OLIS development for CUSP source - gas lines & water 
We received back the source this morning. First order of business was to take some EOB scans. See earlier entry. Then we shut down the source and opened
the cage. Water leaks fixed. We had agreed with ICR to let them go for the sake of continuous beam to our users, so that we could avoid switching off the
source. All done. There is a little weeping on one or two of the source body screws, as expected. As a practical matter, we aren't going to fix these.
Entry  Fri Dec 4 09:58:08 2009, Damien Gallop, , , 20Ne1+ at 28keV for 8pi delivery complete grab.InU319.pnggrab.YPZ323.pnggrab.RXD329.pnggrab.aGj522.pngPicture_1.png
Mike declared successful EOB this morning. "Best beam I ever used" or something like that! EOB emittance and mass scans attached. Note that
slits are at non-standard positions for 5mm gap.
Now we are going to open the source for some maintenance and continue 4He2+ development after that.
Entry  Thu Dec 3 14:12:56 2009, Damien Gallop, , , 20Ne1+ at 28keV for 8pi delivery continues Picture_20.png
Beam was idle overnight. We took the beam for a while this morning, and ran a mass scan. We opted to not go into the cage to install helium gas lines
or fix water lines, because it would mean switching off the source. So we will do the gas tomorrow or so, and fix the water leaks then too.
Note that the separator field is up about 4G from this morning.
Entry  Wed Dec 2 19:03:55 2009, Damien Gallop, , , 20Ne1+ at 28keV for 8pi delivery Picture_19.png
The source ran well overnight and today. There is an issue with an ILE Faraday cup. Tuning is ended for today, and beam is on FC6.
Entry  Tue Dec 1 12:33:58 2009, Damien Gallop, , , 20Ne1+ at 28keV for 8pi 8x
By agreement, we are providing OLIS beam to the Beam Delivery group for the purpose of checking out transmission in the 8pi line. We have set up a 20Ne1+
beam at 28keV. There are some 3nA on FC6.
Here are optics numbers for IOS section:
Entry  Tue Dec 1 09:27:17 2009, Damien Gallop, , , OLIS development for CUSP source - first overnight running Picture_16.pngPicture_15.png
The CUSP source ran well overnight, notwithstanding local control of source power supplies. Filament supply had dropped to 115A this morning, which is
approximately 10A over a 16 hour period. Attached are charts of 4He2+ beam on FC6, an archive chart and a fast stripchart of the last six hours. Shortly
we will begin setup for an 8pi shakedown run today.
Entry  Mon Nov 30 16:53:31 2009, Damien Gallop, , , 20Ne1+ to 8pi planned for tomorrow 
OLIS beam to 8pi is planned for tomorrow. A 20Ne1+ beam of ~3nA at 28keV is the agreement. The 8pi line diagnosis is likely to take a couple or three
days.
Entry  Mon Nov 30 15:41:00 2009, Damien Gallop, , , OLIS development for CUSP source - initial tests 
We completed the services by end of last week. Of course they could always be better, but everything is fine for this iteration. Keerthi had a first
beam out of the source (to FC3) on Friday, with no source gas flowing. Today we started it up, and got first beam this morning. First 4He beam was observed
on FC6 at around 10:45, and 4He2+ a few minutes later. Plenty of development to go, but it works.
Entry  Mon Nov 30 15:41:00 2009, Damien Gallop, , , OLIS development for CUSP source - initial tests Picture_14.png
We completed the services by end of last week. Of course they could always be better, but everything is fine for this iteration. Keerthi had a first
beam out of the source (to FC3) on Friday, with no source gas flowing. Today we started it up, and got first beam this morning. First 4He beam was observed
on FC6 at around 10:45, and 4He2+ a few minutes later. Plenty of development to go, but it works.
Entry  Fri Nov 27 13:36:09 2009, Damien Gallop, , , OLIS development for CUSP source - installation cont'd 
Arc power supply replaced. Water leaks down to one or two pinholes on source body; manageable. Minor mechanical in progress.
Vacuum Group experts looked at IOS:BP1, reported noisy for a minute yesterday. Basically, keep a watch. It should be okay to Shutdown. We will
order a seal kit and negotiate for a backup scroll pump.
Entry  Thu Nov 26 16:08:42 2009, Damien Gallop, , , OLIS development for CUSP source - installation cont'd grab.I31500.png
Services completed today. There are still some teething pains, particularly the arc p/s as noted earlier. But we did have some beam on around noon for
the first time, using neon source gas. Plan is to install helium source gas at the last minute, after all other checks, particularly leak checks, and a
background calibration are done.
Entry  Thu Nov 26 06:22:58 2009, Keerthi Jayamanna, , , Cusp source 
Arc power supply does not hold any voltage.
Entry  Thu Nov 26 06:20:21 2009, Keerthi Jayamanna, , , Supernanogan Development 
Swiched off all the pumps and ion gauge for oven installation.
 
Entry  Tue Nov 24 13:55:55 2009, Damien Gallop, , , OLIS development for CUSP source - installation cont'd 
Keerthi found and fixed a couple more vacuum leaks last night. Present vacuum at IOS:IG1 = 4.4e-7 Torr. Electrical and water services installation in
progress right now.
Later... Most of the services installed. Water tested: mostly OK, but persistent leaks on fiddly source body seals. Let Keerthi adjust these tomorrow.
Entry  Mon Nov 23 10:32:34 2009, Damien Gallop, , , OLIS development for CUSP source - installation cont'd 
4He2+ "alpha" CUSP source under vacuum: IOS:IG1=7.3e-7 Torr. Electrical installations today.
I3 development source also at vacuum: 2.7e-6 Torr, which is better than when we started. TP gauge: 1.0e-7 Torr.
Later... Begin leak checking. Note: IOS:BP1 needs servicing. Its base pressure is ~30mT.
Entry  Fri Nov 20 17:26:57 2009, Damien Gallop, , , OLIS development for CUSP source - installation 
Today we installed the CUSP "alpha" source on the MWS port at OLIS. It is vacuum-tight. Looking good. Also we installed remaining components
on the prototype I3 source yesterday and pumped overnight. Vacuum there is good too. Next week is looking like a marathon source week. I also understand
that a new target for ISAC tested well at the ISAC Test Stand today. A hat trick.
Entry  Thu Nov 19 11:14:19 2009, Damien Gallop, , , OLIS development for CUSP source 
Pumps were switched off last night. IOS was vented to Ar and swiped clean this morning. MCIS ready for disembarking from F-cage. IOS:IV0 defeated so
that we could vent the IM with IOS as one volume.
Later... Supernanogan cart is parked at its service dock. TP1 & 2 are up.
Entry  Wed Nov 18 23:46:14 2009, Keerthi Jayamanna, , , OLIS development started 
All turbos in the OLIS and MCIS are off. No controls for the MCIS. Pumps switched of by pulling the CG cable.
All the gate valves are off. All bypass are removed
Entry  Tue Nov 17 09:18:37 2009, Damien Gallop, , , 21Ne4+ to DRAGON for charge distribution studies Picture_2.pngPicture_1.pngPicture_2.pngPicture_5.png
After their EOB with 17O3+ yesterday, DRAGON switched to 21Ne4+ running for charge distribution studies. Keerthi changed over the source gases for that
around 08:30 yesterday. Things went well. Beam intensity dropped off and leveled off overnight. I tweaked up the source just now. Current at H2:4 moved
from xe-10 to ~1.5enA. A stripchart is attached. Orange trace is H2:4, and green is COL0, which reflects total beam from the source.
Entry  Mon Nov 16 10:00:41 2009, Damien Gallop, , , 17O3+ beam to DRAGON end of run this morning Picture_1.png
DRAGON declared EOB at around 08:00 today. Source and beam were switched to 21Ne4+ for calibration studies.
Entry  Fri Nov 13 10:26:07 2009, Damien Gallop, , , 17O3+ beam to DRAGON continuing Picture_1.pngPicture_2.png
Beam and energy changes continued over the weekend. The ICR reports that things are going swimmingly, and that the users are happy. Scaler counts are
up some 30% or so from Tuesday. All good. A source and line touch-up Wednesday (Remembrance Day) morning and a tuning effort following an energy change
during the day on Wednesday produced strong and stable beam running.
Entry  Tue Nov 10 09:36:39 2009, Damien Gallop, , , 17O3+ beam to DRAGON continuing Picture_1.png
Beam ran well overnight. Last evening Vacuum Group diagnosed and repaired a catastrophic leak in the ILT cross region. You can see in the attached plot
how venting that section caused elevated pressures in IOS, most likely due to the direction in which IOS:IV7 is installed. Most often it is the IOS section
that is vented, and the neighbouring sections remain at high vacuum. So this gate valve would be installed looking downstream so that venting on the upstream
Entry  Mon Nov 9 09:30:10 2009, Damien Gallop, , , 17O3+ beam to DRAGON 
Beam delivery continued through the weekend. As noted on Saturday, current dropped precipitously due to source gas pressure. We have 2.3e-6eµA
this morning.
Entry  Sat Nov 7 12:21:35 2009, Keerthi Jayamanna, , , 17O hand valve status 
17O+3 at FC6 became 550nA.
17O hand valve found to be closed. Probable cause may be the cold weather.
After opening the valve beam came back. 2.6uA of 17+3 at FC6.
Entry  Fri Nov 6 11:17:54 2009, Damien Gallop, , , 17O3+ setup to DRAGON Picture_9.png
As noted, we handed over the beam to our users yesterday by noon. Setup to DRAGON is continuing. The report this morning that beam is great. Good.
Entry  Thu Nov 5 09:45:03 2009, Damien Gallop, , , MCIS online with 17O3+ on FC6 overnight Picture_7.png
Beam was quiet overnight. Keerthi touched up the tune this morning, and it is quieter yet and a little more of it too.
Later... Handover to Sophia occurred as scheduled. Save: 091105_1203.snapiosdragon
An IOSIOC reboot occurred sometime over the lunch hour. The usual suspects went down, plus the field stability correction power supply went to
Entry  Wed Nov 4 09:46:07 2009, Damien Gallop, , , MCIS online with 17O3+ on FC6 for development 9x
Beam stayed up overnight nicely. Development today. RF scans in progress now.
Later... scanning done for the moment. Controls is looking at a PLC issue that has been on the books for a while. I have given the okay to turn
on and off MCIS:IG1 at will.
Entry  Tue Nov 3 09:25:31 2009, Damien Gallop, , , MCIS online with 17O3+ on FC6 overnight Picture_1.png
We completed 33S operation last night, and roughed in a setup for 17O. We had 17O3+ on FC6 overnight; chart attached. It grew nicely. Keerthi is working
with the beam now.
Entry  Mon Nov 2 17:42:54 2009, Damien Gallop, , , MCIS online with 17O3+ on FC6 
As noted earlier, we have opened the OLIS cage and set up the source gases for 17O operation. It will take a while for the SO2 to pump away and for the
17O2 to equalize within the source body. Meanwhile, we have restarted the source with a preliminary 17O3+ beam on FC6. Without a doubt this will be unstable
for a time, and the source may blink out also.
Entry  Mon Nov 2 09:32:40 2009, Damien Gallop, , , MCIS on with 33S5+ on FC6 over the weekend Picture_1.pngPicture_2.pngPicture_3.pngPicture_4.png
Beam came up nicely on  Friday, and stayed up quuietly over the weekend. Note the absence of periodic spikes in the separator field readback since
the last IOC reboots.
Later... I have asked ICR to make us a nice emittance scan. (They are running beam at 8pi presently as well.)
Entry  Fri Oct 30 09:44:49 2009, Damien Gallop, , , MCIS on with 33S5+ on FC6 overnight Picture_2.pngPicture_1.pngPicture_2.pngPicture_3.png
Controls finished with IOSIOC work yesterday. ICR had restored most optics. I restarted the source last evening. As you can see below, the beam grew
nicely overnight. Sometime today I will ask ICR to reboot IOSIOC and see if everything stays up now.
One more thing. The chart shows the last couple of days' running. Prior to beam-off for IOSIOC, we observed periodic spikes of about 45m each in
Entry  Thu Oct 29 09:42:23 2009, Damien Gallop, , , IOSIOC work in progress 
Yesterday there was an IOSIOC reboot for a purpose. It was an opportunity to demonstrate to Controls that IOSIOC reboots materially affect the IOS section.
Controls responded to an ICR fault report on it, and have not reported back to ICR so far. The source was off overnight and remains off now. I have informed
ICR that if nothing happens this morning, I will restart the source after lunch.
Entry  Wed Oct 28 09:55:28 2009, Damien Gallop, , , Planned IOSIOC reboot Picture_1.pngPicture_2.png
Controls is rebooting IOSIOC. I have inserted MCIS:FC1 for the duration. Let's see what comes of it all.
Later... As expected, the reboot zeroed our optics. ICR issued a FR#4179
on it. Meanwhile, I rechecked the A/q calibration, and found it off a little. Below are before and after shots. The latter shows scanning in both directions.
Entry  Wed Oct 28 09:33:51 2009, Damien Gallop, , , MCIS on with 33S5+ on FC6 overnight cont'd Picture_1.png
Beam was quiet overnight. I noticed a slow drift that seemed to follow the source pressure. My best guess is that our source gas "regulator"
is a little coarse at these flows. Save: 091028_0935.snapiosfc6
Entry  Tue Oct 27 09:22:14 2009, Damien Gallop, , , MCIS on with 33S5+ on FC6 overnight Picture_7.pngPicture_8.pngPicture_3.pngPicture_4.png
I had optimized the RF yesterday, but the source went into a dual-mode toggling regime. It is hairline to find a nice point. I also found that it responds
better if frequency is approached from high to low.
Later... After some tweaks earlier, beam is looking pretty good, a solid 3enA at FC6.
Entry  Mon Oct 26 10:56:52 2009, Damien Gallop, , , MCIS on with 33S5+ on FC6 over the weekend Picture_4.png
On Friday we left 33S5+ on FC6. The separator magnet power supply tripped at some point for unknown reason. The operators turned it on again overnight.
Keerthi tweaked and tuned early this morning and just recently. Beam is back to FC6, but displayed A/q is off, though the actual beam is correct.
Entry  Fri Oct 23 09:55:41 2009, Damien Gallop, , , MCIS on with 33S5+ on FC6 overnight cont'd Picture_2.pngPicture_3.png
Beam stayed on quietly overnight, as did the separator stability program. Periodic pulsing continues to occur. No explanation has been proffered so far.
Adding ferrite cores appeared to clamp the high spikes, but high spikes reappeared around midnight. There does not appear to be any real effect on the
beam or separator.
Entry  Thu Oct 22 15:54:24 2009, Damien Gallop, , , MCIS on with 33S5+ on FC6 overnight cont'd pulse.pngpulse-clip.pngpulse-tweak.png
The Supernanogan was on overnight quietly. FC6 went in this morning. (Didn't check if fingers were involved.) I  now notice a strange pulsing in
our Stripchart. See what you think. Note: field and A/q max scales are orders of magnitude higher than real life.
Later...At around 14:00 I added ferrite cores to the field probe cable at the CANbus interface box. That clipped the high side of the pulses completely.
Entry  Wed Oct 21 11:01:37 2009, Damien Gallop, , , MCIS on with 33S5+ on FC6 overnight cont'd 
I alsmost want to write, see yesterday's entry! Source ran quietly with no interruptions. FTR, the separator stability program is also percolating along
nicely. It was taking hits from nearby EMI until I added a ferrite split core to its USB cable at the computer end.
Entry  Tue Oct 20 09:25:29 2009, Damien Gallop, , , MCIS on with 33S5+ on FC6 overnight 
The source stayed up quietly overnight with about 4enA on FC6. Once in a while a little burp occurs, visible as small beam and vacuum spikes. I have
tweaked the RF frequency up a little for better centre of range.
Entry  Mon Oct 19 10:09:13 2009, Damien Gallop, , , MCIS on with 33S5+ on FC6 Picture_5.png
Switch on source for stats. Source lit up perfectly. Slight adjustment on RF frequency.
Entry  Thu Oct 15 21:06:10 2009, Keerthi, , , OLIS status 
33S development is completed.  A 3nA of 33S+5 can be produced with 10W of RF power and 2.5mm aperture.
If more beam is needed apertures and the power must be increased.  There are some consequences for doing this.
MCIS optics and RF are off for the night.
Entry  Thu Oct 15 09:43:00 2009, Damien Gallop, , , MCIS development with 33S5+ Picture_3.png
Source started. 33S5+ beam on FC6 using gas flow determined yesterday. At first blush, it appears we need a slightly higher flow. But for now we will
spend some time optimizing with what we have. We may open and adjust the flow later.
Later... This flow is okay for now. It requires a *really* fine control, which we do not have at present. 3enA with 10W of power. One source spark
Entry  Wed Oct 14 12:06:46 2009, Damien Gallop, , , MCIS development with 33S5+ grab.w30542.png
MCIS was running with background only. Prepare to open SO2 source gas...
MCIS:IG1 = 5.4e-8 Torr
TP1 = 13W
Entry  Wed Oct 14 09:52:09 2009, Damien Gallop, , , MCIS development with 33S5+ today Picture_6.png
The source is on. There is background beam on FC6 presently, less than yesterday. That's probably a good thing. Let it cook for a bit, then check the
tune. Note: EL is off, as yesterday.
Entry  Tue Oct 13 14:14:17 2009, Damien Gallop, , , MCIS setup for 33S5+ Picture_2.pngPicture_3.pngPicture_4.pngPicture_5.png
Keerthi has reinstalled the SO2 source gas bottle onto MCIS. Presently it is closed off to the source. We have restarted the plasma. Present goal: a
good setup for 33S5+ with background levels (hopefully near zero) on FC6. Source pressure was 4.xe-8 Torr this morning, and has crept up to 5.0e-8 since
we restarted the RF.
Entry  Sun Oct 11 17:11:31 2009, Keerthi, , , MCIS turbo pumps power levels 
MCIS:TP1 = 12W
MCIS:TP2 = 11W
Entry  Sun Oct 11 17:09:52 2009, Keerthi, , , Vacuum with IOS:IV7 
IOS:IG4 reads 1.25 e-7 Torr and IOS:IG1 reads 9.8e-8 Torr with IOS:IV7 is open
IOS:IG4 reads 8.35 e-8 Torr and IOS:IG1 reads 7.49e-8 Torr with IOS:IV7 is closed
Entry  Sun Oct 11 13:17:37 2009, Keerthi, , , Neon Leak closed 
Neon leak close for upcoming 33S development.
Entry  Sun Oct 11 13:16:39 2009, Keerthi, , , MCIS:TP3 was off 
MCIS TP3 foumd off by 1:00 pm.  Restarted without a problem
Before TP3 is on MCIS:IG1 is 5.47e-8 Torr.
After MCIS:TP3 = 5.21e-8 Torr
Entry  Fri Oct 9 16:33:45 2009, Keerthi, , , 33S development 
SO2 gas line is connected again. Leak hand valve is closed.
Intermediate section is pumping through source chamber.
CSB development is completed.
Entry  Thu Oct 8 09:39:52 2009, Damien Gallop, , , CSB Development with MCIS MCIS_HV_Conditioning.png
Friedhelm and Marco have requested 20Ne2+ from the Supernanogan, and plan to bring up the same from the CSB today. I am beginning MCIS bias conditioning.
Goal: 24kV, maybe 25. Last save: 091008_0933.snapiosfc6
Later... Conditioning completed to 26kV. Set up a 20Ne2+ tune. It's largely a manual operation. Q3 off in keeping with the failure that occurred
Entry  Wed Oct 7 16:54:33 2009, Keerthi, , ,  
Today Supernanogan vacuum found to be down in the morning. Restarted easily.
Entry  Tue Oct 6 15:28:31 2009, Keerthi, , , OLIS A/Q changed to 5 (20Ne+4) 
Changed OLIS A/Q to 5 (20Ne+4) to satisfy the CSB and ISAC development changes. 8nA is sitting at the FC6
Entry  Tue Oct 6 15:22:43 2009, Damien Gallop, , , 22Ne4+ & 20Ne4+ operation 20Ne4_on_FC6.png
Over the weekend, Keerthi had set up 22Ne4+ to FC6 for the purpose of developing a tune matched with a similar tune from the CSB. However, yesterday
it turned out that the CSB could not generate a 22Ne beam sufficiently bright for tuning. So the project was scrapped. Keerthi then changed the source
for 20Ne4+ operation, and handed it over to Marco yesterday. I think that is going well. Here is a trar plot of overnight beam.
Entry  Sun Oct 4 19:16:46 2009, Keerthi, , , OLIS status 
Supernanogan is ready with 22Ne+4 for upcoming CSB run. EL, HV and RF are on. The anlyzing magnet and the other optics are set for A/Q=5.5.
A 2nA of 22Ne+4 is sitting at the FC6. If require more current, increase the RF up to 25W or change the frequency to 13.256GHz.
Entry  Fri Oct 2 15:58:36 2009, Keerthi, , , 17O and Ne gases are now connected 
A  1e-5 atm.cc/sec of 17O leak and a 1e-6 atm.cc/sec of neon leak are connected to the source through center tube of the RF transfer antenna.
Ne valve is open for upcoming CSB test.  17O valve is closed. All optics are set to A/Q=5.5.  RF, EL and HV are off for the weekend since
no ISAC ops at night.
Entry  Fri Oct 2 09:38:26 2009, Keerthi, Routine, General, 33Sulfur development completed successfully. 
 
Sulfur-33 development completed successfully.
Three times of the requested
amount produced (1e9 x 3) from the source and two times
delivered to the DRAGON for verification.
Entry  Wed Sep 30 15:30:04 2009, Damien Gallop, , , 33S6+ from MCIS for DRAGON setup grab.sA3956.pnggrab.ar3960.png
Beam is stable enough to let Marco set up something to DRAGON. We are a couple of days early.
Also, we tested the attenuators, previously noted to be operating oddly:

    
Entry  Mon Sep 28 14:16:47 2009, Damien Gallop, , , MCIS Cart down for TP1 Replacement 
We are taking the opportunity to replace TP1 today. Edi Dalla Valle is on it. Also, Diagnostics has a WP in the queue for looking at the attenuators,
so we have prepared IOS for venting.
Later... Cart was removed from cage for access. Pump was replaced successfully, and all volumes are under high vacuum now (17:00). In the end,
Entry  Mon Sep 28 14:12:17 2009, Damien Gallop, , , 33S5+ from MCIS on Friday 25-Sep-2009 33S_from_MCIS_25-Sep-2009.png
A sustained 33S5+ beam was generated in the Supernanogan on Friday, September 25th. Attached is a trar plot.
Source gas: SO2 through either of two calibrated leaks: 10-4 and 10-5ccm.
FC6 = 1enA.
Entry  Wed Sep 16 18:14:29 2009, Damien Gallop, , , Test scans for publication 2 19x
090916_1206ILTEMIT.txt
Graphics with "color" in the filename will look in print the same as "greyscale" files.
Entry  Wed Sep 16 12:48:13 2009, Keerthi, , , 17O+5 double peaks grab.U24653.pnggrab.s24670.pnggrab.s24675.pnggrab.d24681.pnggrab.u24686.png
090916_1242ILTEMIT.txt  17O+5 has two peaks.
090916_1355ILTEMIT.txt  Repeat same measurement an hour later. (IOS bias was off in-between due to IOC/PLC reboots.)
Entry  Wed Sep 16 12:26:51 2009, Keerthi, Routine, General, 17O+3 emittance with changed steering 
090916_1222ILTEMIT.txt  Changed the MCIS steering to center the beam in the EL. 17O+3 ~5uA, 50x100
Entry  Wed Sep 16 12:20:10 2009, Keerthi, , , 17O+3 emittance with increased EL 
090916_1215ILTEMIT.txt    EL increased, ~4.5uA, emittance increases, 50x100   17O+3
Entry  Wed Sep 16 12:12:04 2009, Keerthi, Routine, General, 17O+3 emittance sacns 
090916_1156ILTEMIT.txt      17O+3  good settings 50x100 ,   333nA Scale, ~4uA
090916_1206ILTEMIT.txt      17O+3  good settings 100x200 ,   333nA Scale, ~4uA
Entry  Tue Sep 15 20:02:46 2009, Keerthi, , , 17O8+ on FC6 from MCIS grab.I24583.png
0.4nA of 17O+8 is sitting on FC6. Development will continue tomorrow.
Entry  Tue Sep 15 19:46:21 2009, Keerthi, Routine, General, Supernanogan emittance scans 9x
090915_1915ILTEMIT.txt = 17O +3,  4.4uA new tune, scanner offset +10V,  scanner scale 100nA , 100x50 matrix
090915_1929ILTEMIT.txt = same as above with 200x100 matrix
090915_1949ILTEMIT.txt = after tune tweaking (not optimal; for reference only)
Entry  Tue Sep 15 16:56:03 2009, Damien Gallop, , , Test scans for publication grab.E19994.pnggrab.U19879-greyscale.pnggrab.U19879-cropped.png
Here are pix of the same scan: original, then greyscale, then cropped, using The GIMP. Not bad.
Entry  Tue Sep 15 16:09:31 2009, Damien Gallop, , , MCIS Development 17O emittance scans 13x
We noticed a double peak effect in the 16O3+ scan. I will set up the line for 17O3+ and see.
Scan #1: Double peak also visible.
Scan #2: Remove upstream slit altogether. Now profile is twice the size in the opposite direction of the double peak.
Entry  Tue Sep 15 10:32:39 2009, Damien Gallop, , , MCIS Development 7x
So. We are preparing for a few days of Supernanogan development. The present run plan is to obtain good emittance scans for higher charge states of 16O,
17O and 18. We may be limited by the loss of MCIS:TP1, but maybe not.
Set up on nom 18kV tune based on last recent save: 090831_1104.snapiosfc6. MCIS HV tickled up to prevent extracted beam surges.
Entry  Tue Sep 15 09:54:22 2009, Damien Gallop, , , 16O3+ run to DRAGON ended on schedule at 08:00 8x
The DRAGON run ended uneventfully. (That's a good thing.) I ran a few emittance scans on the beam as-is. It is clearly monoisotopic. The shape is a little
odd. Keerthi will comment on it in a while. Here are some pix. Below the emittance control panel are pix of the same beam at wider settings. Only the one
16O3+ peak is present. Finally, at the bottom is a pic of various parameters, the most important of which is COL0, which reflects the stability of the
Entry  Fri Sep 11 23:42:45 2009, Keerthi, Other, General, MCIS turbo pump mcis_multi-state.png
MCIS TP1 is not running well. Needs investigation as soon as S1219 is completed.
Later... TP1 failed completely, and we are running without it. Starting late Saturday night, DRAGON began to observe a certain instability. We
correlated it to MCIS:COL0, which skims total current continuously. It is pretty evident that the source is now toggling between two adjacent plasma modes,
Entry  Tue Sep 8 15:14:45 2009, Damien Gallop, , , Back from vacation magstab_off-on.pngmagstab_on_10-sep-2009.pngmagstab_on_14-sep-2009.png
I'm back from vacation. Physically, anyway. Keerthi did comprehensive emittance scans during Supernanogan Development over the last couple of weeks.
He is very happy with the results so far. We are doing come post-analysis comparisons presently. Meanwhile, DRAGON is taking 16O3+. Some sideshows, including
power bumps this morning which knocked out MCIS and many other systems. The mag stab facility was offline while I was away. I restarted it around noon.
Entry  Tue Aug 18 11:16:16 2009, Damien Gallop, , , MCIS "PV" PLC trip overnight grab.SXu928.pnggrab.eG1166.pnggrab.di1170.png
Another in the on-going saga of MCIS:PV1 trips occurred again this morning. The operators recovered most of the vacuum devices except for the IM section
gate valves. We had an in-person discussion about them, the order in which they should be opened, and the existence of a hand valve in the IM roughing
line. An ION note is needed.
Entry  Mon Aug 17 15:53:54 2009, Damien Gallop, , , MCIS mass scans & initial emittance scans 11x
High resolution zero to 25. Save file: masscorr_mcis_090817-highres.txt
Ack! Elog server went down at ~17:00!!!
18O4+ emittance scan at 22.44kV and slits open: 090817_1707ILTEMIT.txt
Entry  Mon Aug 17 13:58:35 2009, Damien Gallop, , , Supernanogan Development begins today for one week Picture_43.pnggrab.a30699.png
Supernanogan Development begins. It will be a marathon. Main goals are high-charge emittance scans and RF frequency scans. Tall order.
Meanwhile, the MWS came out as planned. Thank goodness for the quartz liner, which took most of the hit from the magnesium. IOS optics are another
story. We are running with an alternate tune for Q1/Q2/Q3, as noted elsewhere. The Supernanogan, already at vacuum, pumped down nicely, as did IOS and
Entry  Fri Aug 14 13:53:34 2009, Damien Gallop, , , MWS 25Mg end of run data 10x
Marco gave us the all-clear this morning to shut down the MWS. We are preparing to remove the MWS head from the Y-box and blank it off, in order to maximize
the vacuum around the Supernanogan. I have advised Marco of our intention to do this and that there is no going back. He is good with that. More in a bit.
Here is a stripchart of the 25Mg beam. The EE was off for the night. Turning it on restored beam immediately. It reached equilibrium after about
Entry  Tue Aug 11 09:54:28 2009, Damien Gallop, , , MWS 25Mg operation overnight & MCIS cart installation grab.Z26532.pnggrab.Y26538.png
As noted earlier, the MWS beam dropped out at some point after yesterday afternoon's playtime, due to insufficient PE. Plasma was lost. I restarted the
source remotely. The present combination of Ne flow SP = 1.2ccm and PE = 48V works well. Plasma will persist regardless of Mg presence or PE setting. That's
a good thing. Then using the PE we can control how the plasma ionizes the Mg material. Note the attached stripcharts. At the lower PE settings, the Mg
Entry  Mon Aug 10 18:29:32 2009, Damien Gallop, , , MWS source trip & restart grab.q23803.png
Well, so it goes. As I was penning a note for OPS, the source tripped. It easily reignited with a little extra Ne. I left the flow slightly higher, from
1.1 to 1.2ccm and the PE at 41V.
Entry  Mon Aug 10 18:06:09 2009, Damien Gallop, , , MWS 25Mg reduce intensity with PE grab.W23753.png
So... we have had this on-going problem with intense Mg beam coating our optics. Keerthi found a good recipe last week with PE on and a somewhat large
support gas flow. We have been running with several tens of nA since. Since yesterday's trip, I have been gradually lowering the PE from my initial value
of 100V to 30V presently with about 10nA on FC6. Beam looks like it will be very stable, and the EE will maintain indefinitely like this. The first test:
Entry  Mon Aug 10 17:42:18 2009, Damien Gallop, , , MWS 25Mg emittance scan with original settings 6x
Finally, here is the "original" beam. Can you tell the difference (side-by-side at bottom)? I can't.
Data file: 090810_1738.ILTEMIT.txt
Entry  Mon Aug 10 17:20:55 2009, Damien Gallop, , , MWS 25Mg emittance scan with zeroed vertical steerers grab.k23573.pnggrab.m23577.pnggrab.v23582.pnggrab.U23599.png
Here is a variation I thought might be appropriate.
Data file: 090810_1724ILTEMIT.txt
Entry  Mon Aug 10 17:16:20 2009, Damien Gallop, , , MWS 25Mg emittance scan with downstream quads off grab.E23496.pnggrab.o23517.pnggrab.J23522.pnggrab.Q23526.png
Here is the emittance scan that Rick requested, beam with Q4/5/6 off. Note that present numbers for these quads do not match theoretical. I repeated
my slit nudge check for clipping, just in case. As before, no clipping for the first mm or more.
Data file: 090810_1713.txt
Entry  Mon Aug 10 16:43:59 2009, Damien Gallop, , , MWS 25Mg emittance scan with slits open grab.G23396.pnggrab.g23400.pnggrab.r23404.png
Before proceeding, I nudged in each of the slits, watching for first clipping. With the current emittance (nice), the beam cleared both slits completely;
the upstream slit began clipping at about 1.5mm, and the downstream one at about 2mm. Also, FC6 current with slits in/out was: ~30nA / ~57nA. Note: I had
to change the scanner parameters a little.
Entry  Mon Aug 10 16:36:33 2009, Damien Gallop, , , MWS 25Mg emittance scans grab.d23286.pnggrab.w23291.pnggrab.U23295.pnggrab.U23312.pnggrab.q23316.png
A series of 25Mg emittance scans for Rick.
Starting scan with everything as-is, i.e. slits closed.
Data file: 090810_1621ILTEMIT.txt
Entry  Mon Aug 10 16:12:28 2009, Damien Gallop, , , MWS 25Mg operation over the weekend grab.m23211.pnggrab.F23215.png
Summary: good.
Details: A trip occurred at some point. I restarted the source over the weekende remotely. I have been tweaking down the PE since. Looking mighty
fine. Stripcharts attached. Separator field nicely flat too, with stability program running. Save: 090810_1605.snapiosfc6
Entry  Fri Aug 7 14:42:29 2009, Damien Gallop, , , MWS 25Mg beam reduction grab.jpa367.pnggrab.zFr371.pnggrab.PTd375.pnggrab.DYQ403.png
Around noon, Keerthi adjusted the PE down to reduce the intensity of the Mg beam, as we are running with attenuators in. He ended up with about a 30%
reduction, and improved the noise band by about 3x in the process.  Here is a repeat emittance scan. Both sets of slits are at 2.5mm position. I also
took the opportunity to reset the separator stability equipment again.
Entry  Fri Aug 7 10:16:38 2009, Damien Gallop, , , MWS 25Mg emittance scans 6x
While there is an SC cavity issue, I have been repeating last evening's emittance scans. Here is the best one. About 70nA of 25Mg on FC6 presently. Note
that emittance rig Faraday cup is reverse-biased. Also, overnight stripchart appended. You can see a gradual increase in current draw on the EE power supply
as there is a build-up of Mg.
Entry  Thu Aug 6 17:02:00 2009, Damien Gallop, , , MWS 25Mg tuning to TIGRESS in progress 7x
Tuning has been on-going through the day. Here are a couple of emittance scans taken in-between heartbeats. The first is zoomed out, the second zoomed
in a little close. We managed to sneak in a third also.
Entry  Wed Aug 5 11:29:51 2009, Damien Gallop, , , MWS operation overnight and 25Mg status grab.G24908.pnggrab.h24912.pnggrab.T24916.pnggrab.W24925.pnggrab.x24953.png
So... there evidently was a power bump overnight, because the stability power supply was "disconnected" from the system. This happens every
time there is a power bump. It's a serial port thing. Meanwhile, the source also tripped. Upon restart, nothing was the same. This morning, we found that
Q3 was current-limiting on one element. We have asked Rick to develop an alternate tune for us.
Entry  Tue Aug 4 11:13:04 2009, Damien Gallop, , , MWS source tuning for 25Mg operation 6x
The source stayed up overnight just fine, with a little 25Mg beam on FC6. This morning I did a few mass scans to get a fix on Mg positions. Short story:
There are some 3nA of 25Mg on FC6 presently, with things less than optimal. Stay tuned.
Attached is an early graph of Mg beams produced with the MWS almost exactly five years ago. Best I could find for now.
Entry  Mon Aug 3 08:39:31 2009, Damien Gallop, , , MWS 21Ne -> 25Mg switchover grab.f18355.pnggrab.n18345.png
Conveniently scheduled for BC Day, we are preparing to switch over the MWS to sputter operation with MG source material. Operations has saved present
21Ne tune.
Later... Done! Source is relit with 21Ne beam on FC6.
Entry  Mon Jul 27 14:39:22 2009, Damien Gallop, , , 21Ne5+ to TUDA-II 
21Ne has been available from the MWS since mid-week. Here is roughly how last week unfolded to now:
Monday: MCIS -> MWS and remove MCIS cart
Tuesday: leakcheck MWS source gas manifold
Entry  Wed Jul 22 14:31:28 2009, Damien Gallop, , , 21Ne setup to TUDA-II is underway Picture_27.pngPicture_24.png
Last night Keerthi resolved the sparking issue in MWS and started the source while I was present. There was a frozen interlock condition ion IOS:BIAS,
which Graham resolved today. HV was on by ~11:00. Beam on FC6 immediately. It looks like Sophia took the beam at that point. I noticed that the Kepco appears
not regulating, and in any event is close to a limit (0.3A). I have asked Sophia for five minutes to reset it.
Entry  Wed Jul 22 01:33:29 2009, Damien Gallop, , , MWS initial startup summary 
Vacuum came down to ~7e-7 Torr. On startup, bias sparked over somewhere. Vacuum leak was caused. Later we found that HV had sparked through the source
gas tubing, which was touching the beamline frame. Obviously an arc had formed within the tube and sparked through on the ground side. We also could not
reset the bias interlock (ICR has efaulted this), so we ran in local. System is set up for 21Ne with about 28nA on FC6. Bias is off for the night, while
Entry  Tue Jul 21 17:11:33 2009, Damien Gallop, , , MWS preparations for 21Ne operation Picture_23.png
With the MCIS cart removed, Geoff hooked up the leak detector to the MWS source gas line. He did a couple of hours of leak checking in this mode. Then
he moved the connection to an empty gas port on the manifold itself. Much qicker responses. We replaced a VCR seal on the bottle side of the right-hand
He solenoid valve. That did wonders. He checked around afterwards, but found no further leak. We tidied up and opened the manifold to IOS. Base pressure
Entry  Mon Jul 20 17:28:01 2009, Damien Gallop, , , MCIS cart removed from cage and parked 
We discussed whether or not to leave the Supernanogan in the OLIS Faraday cage, and decided no, because the up-coming runs will use the MWS at 42 and
52kV respectively, higher than the MCIS HV rating. Bonus: We have more working room in the cage. The cart is out and parked. Services are connected and
up.
Entry  Mon Jul 20 09:25:35 2009, Damien Gallop, , , 18O4+ run to TIGRESS complete grab.rt5424.pnggrab.kH5418.pngPicture_25.pngPicture_24.pngPicture_23.png
The 18O4+ run at about 5MeV/u ended this morning with reasonable success, I'm informed, despite MCIS vacuum trips, SC cryo trips and a power bump for
good measure.This morning I found beam at FC6 unstable. It appeared to be toggling between plasma states. A little tweak of a few MHz up in microwave frequency
not only stabilized it but also multiplied the brightness. Too bad the users didn't have this beam. Emittance scan in progress now.
Entry  Fri Jul 17 11:10:21 2009, Damien Gallop, , , Supernanogan development done 6x
Beam switched back to 18O4+ by 11:00 as agreed. Some glitches. Here are snapshots of how it looked at handover time.
Later... Sophia prefers using all previously-saved files including ion source. Okay.
Note: For fun, Controls took away isacwserv mid-morning. The ICR did not communicate to them that I was the user... Workaround done with Keiko.
Entry  Fri Jul 17 10:46:06 2009, Damien Gallop, , , 16O6+ recheck grab.C25591.pnggrab.q25595.pnggrab.Q25796.pnggrab.w25831.pnggrab.c25693.png
A/q = 2.666 Field = 767.1G FC6 = 3enA
Entry  Fri Jul 17 10:32:42 2009, Damien Gallop, , , 16O8+ recheck grab.X25481.png
A/q = 2 Field = 667.3 FC6 = ~10enA
Entry  Fri Jul 17 10:30:27 2009, Damien Gallop, , , 16O7+ recheck 
A/q = 2.2857 Field = 710.5G FC6 = 100pA
Entry  Fri Jul 17 10:28:09 2009, Damien Gallop, , , 18O7+ recheck 
A/q = 2.571 Field = 753.5 FC6 = 50epA
Entry  Fri Jul 17 10:03:07 2009, Damien Gallop, , , 18O6+ recheck grab.a25266.pnggrab.J25270.pnggrab.C25275.png
A/q = 3 Field = 813.9G FC6 = 2.2enA
I tweaked the adjustment of the displayed A/q calibration to fit this one.
Entry  Fri Jul 17 09:47:16 2009, Damien Gallop, , , 18O8+ recheck 
Go fishing in the range 2.24-2.26, but no fish in this pond this time. However, there is a relatively strong beam at 2.3.
A/q = 2.3 Field = 711.2 FC6 = 110enA
No emittance scan possible.
Entry  Fri Jul 17 09:33:09 2009, Damien Gallop, , , Supernanogan epilogue grab.a24906.pnggrab.Q24916.png
There are the last couple of hours of Supernanogan Development for this set. Our run plan included 17On+ studies. Time will not permit it this time around.
Also, the emittance numbers of 16O and 18O are not distinctive enough as they stand to warrant studies of the in-between mass. Keerthi will run the emittance
data files through his software during post-analysis, and we'll develop our next run plan based on his conclusions.
Entry  Thu Jul 16 17:15:50 2009, Damien Gallop, , , 16/18On+ survey summary 
Here is a summary of emittances gleaned from the aforementioned elog entries.

    
        
            
            A/q
Entry  Thu Jul 16 17:09:52 2009, Damien Gallop, , , 18O1+ survey grab.b17471.pnggrab.r17475.pnggrab.R17480.png
A/q = 18 Field = 1987.1 FC6 = 161nA
Entry  Thu Jul 16 17:05:29 2009, Damien Gallop, , , 16O1+ survey grab.o17385.pnggrab.G17390.pnggrab.B17394.png
A/q = 16 Field = 1873.4G FC6 = 204enA
Entry  Thu Jul 16 16:50:41 2009, Damien Gallop, , , 18O2+ survey grab.N17330.pnggrab.Y17335.pnggrab.w17339.png
A/q = 9 Field = 1405.0G FC6 = 55enA
Entry  Thu Jul 16 16:40:11 2009, Damien Gallop, , , 16O2+ survey grab.u17187.pnggrab.U17191.pnggrab.s17196.png
A/q = 8 Field = 1324.8G FC6 = 172enA
Entry  Thu Jul 16 16:33:28 2009, Damien Gallop, , , 18O3+ survey grab.k17100.pnggrab.e17104.pnggrab.E17109.png
A/q = 6 Field = 1147.2 FC6 = 39.3enA
Entry  Thu Jul 16 16:15:39 2009, Damien Gallop, , , 16O3+ survey grab.F17014.pnggrab.D17019.pnggrab.E17026.png
A/q = 5.3333 Field = 1081.6G FC6 = 110nA
Entry  Thu Jul 16 15:58:53 2009, Damien Gallop, , , 18O4+ survey grab.Q16857.pnggrab.l16862.pnggrab.r16890.png
A/q = 4.5 Field = 993.5G FC6 = 20enA
Entry  Thu Jul 16 15:49:46 2009, Damien Gallop, , , 16O4+ survey grab.W16723.pnggrab.F16727.pnggrab.l16731.png
A/q = 4 Field = 936.7 FC6 = 54.0enA
Entry  Thu Jul 16 15:41:35 2009, Damien Gallop, , , 18O5+ survey grab.d16597.pnggrab.v16602.pnggrab.z16609.png
A/q = 3.6 Field = 888.6G FC6 = 6.2enA
Entry  Thu Jul 16 15:38:58 2009, Damien Gallop, , , 16O5+ survey grab.a16526.pnggrab.l16532.pnggrab.N16536.png
A/q = 3.2 Field = 837.7G FC6 = 14.5enA
Entry  Thu Jul 16 15:22:51 2009, Damien Gallop, , , 18O6+ survey grab.Z16300.png
A/q = 3 Field = 811.2G FC6 = 1.6nA
Not quite enough beam for an emittance scan.
Entry  Thu Jul 16 15:11:16 2009, Damien Gallop, , , 16O6+ survey grab.e16164.pnggrab.z16169.pnggrab.a16173.png
A/q = 2.6667 Field = 764.7G FC6 = 3.0nA
Entry  Thu Jul 16 14:50:38 2009, Damien Gallop, , , 18O7+ survey 
A/q = 2.5714 Field = 751.1G FC6 = 40epA
No emittance scan possible.
Entry  Thu Jul 16 14:46:52 2009, Damien Gallop, , , 16O7+ survey 
A/q = 2.2857 Field = 708.0G FC6 = 70epA (noisy)
No emittance scan possible.
Entry  Thu Jul 16 14:44:06 2009, Damien Gallop, , , 18O8+ survey 
A/q = 2.25 Field = 702.5G FC6 = not visible
It looks like last night's vacuum trip is biting us here.
Entry  Thu Jul 16 14:41:46 2009, Damien Gallop, , , 16O8+ survey 
A/q = 2 Field = 662.3G FC6 = 150epA (unstable)
No emittance scan possible.
Entry  Thu Jul 16 14:25:27 2009, Damien Gallop, , , 18O4+ survey grab.x15815.pnggrab.p15822.pnggrab.x15826.png
A/q = 4.5 Field = 993.5G FC6 = 24.0enA
Entry  Thu Jul 16 14:11:43 2009, Damien Gallop, , , MCOL3 slits calibrations grab.k15763.pnggrab.h15767.pnggrab.J15771.png
I ran through a calibration exercise for the IOS slits. Here is my data. I have moved each set to the midpoint of the largest (5mm) slit position. This
does not necessarily agree with the book value. Never mind. Leave 'em alone, even though it appears that the numbers are switched (they're not).

    
        
             MCOL3A 
Entry  Thu Jul 16 14:06:56 2009, Damien Gallop, , , MCIS vacuum trip overnight grab.X15685.png
The MCIS vacuum system tripped last night again. Fortunately the operators
noticed it and restarted stuff. Otherwise we'd be having a very long day today. This looks exactly like the same MCIS:PV1 trip we've experienced before.
Attached is the FC6 beam recovery.
Entry  Wed Jul 15 16:37:01 2009, Damien Gallop, , , Bias for IOS emittance rig grab.wu7505.pnggrab.Vo7510.pnggrab.le7613.pnggrab.TN7617.png
Graham looked up the list of IOS bias assignments. None was form the emittance rig. I quickly tested the list in ILT, but nothing jumped out. Keerthi
provided a battery setup, which I have now installed. Here are example scans, untouched, of forward and reverse bias. I leave it to you, dear reader, to
figure out which is which.
Entry  Wed Jul 15 14:41:25 2009, Damien Gallop, , , 18O5+ survey grab.Nr6887.pnggrab.ag6892.pnggrab.sV7547.pnggrab.Sg7555.png
A/q = 3.6 Field = 888.6G FC6 = 10nA
Two emittance scans, one with the as-is emittance rig, one with a manually installed battery for bias.
Entry  Wed Jul 15 10:52:25 2009, Damien Gallop, , , 18O6+ survey 7x
A/q = 3 Field = 813.2 FC6 = 2.9nA
Beam is too faint for a good emittance scan, but it's visible. Redo with reverse bias, if possible...
Sideshow: IOSIOC reboot for Maintenance. Recovery protracted... Some MWS bias interlock problem. Also, many optics devices were zeroed. (When will
Entry  Wed Jul 15 10:51:25 2009, Damien Gallop, , , 18O7+ survey 
A/q = 2.571 Field = 752.9 FC6 = 88pA
Entry  Wed Jul 15 10:41:23 2009, Damien Gallop, , , 18O8+ survey grab.dg7993.png
A/q = 2.25 Field = 704.7G FC6 = <pA
Well, it's there, but pretty faint. The attached stripchart shows no beam then beam. FC6 bias has to be revered to see it.
Entry  Wed Jul 15 10:27:18 2009, Damien Gallop, , , 18O4+ overnight and emittance check grab.tL7839.pnggrab.An7844.pnggrab.fH7848.pnggrab.Jq7854.png
Repeat emittance scan of present 18O4+ beam. It compares okay (somewhat broader emittance numbers)  with yesterday's scan. Also attached is FC6
beam overnight. Nice.
Entry  Wed Jul 15 09:20:26 2009, Damien Gallop, , , Supernanogan development in progress 
Proposed run plan for this time:

    Document TIGRESS tune.
    18O4+ emittance scan.
    Mass scan A/q = 0 to 25.
    Repeat 18On+ emittance
scans at present RF frequency. 
    16On+ emittance scans at present frequency.
    Plot 16On+ & 18On+ emittance on one graph.
Entry  Tue Jul 14 15:19:51 2009, Damien Gallop, , , MCIS mass scan grab.qQ4911.png
I have begun a mass scan from 0 to 25. It will be a while. Data file: masscorr_mcis__0-25_090714.txt.
25nA of 18O4+ restored to FC6.
Entry  Tue Jul 14 09:47:14 2009, Damien Gallop, , , 18O4+ tuning to TIGRESS this morning 7x
We have a change of schedule. Due to circumstances, Sophia will continue tuning to TIGRESS this morning. Sgan Development will resume this afternoon.
Details: The beam path through the TIGRESS chamber is clear presently, and no detectors are mounted. It is the perfect time to send a nA pilot
beam to the end of the line. TIGRESS intends to install electronics starting at noon. Sophia expects to have tuning comfortably completed by then also.
Entry  Mon Jul 13 17:41:04 2009, Damien Gallop, , , Supernanogan development Monday morning Picture_20.png
As noted, Keerthi was called to restart the source after a power bump. He continued Supernanogan development through the night (can you imagine?!?).
He made some great progress. Here is a partial summary of his findings.
Actions taken: frequency scans across the entire range from 12-16GHz for each charge state of 18O.
Entry  Mon Jul 13 17:19:29 2009, Damien Gallop, , , MCIS vacuum trip at ~15:30 grab.Z26697.png
An MCIS vacuum trip occurred somewhere around 15:30. Sophia observed a drop-off in beam. The cause looks like the PLC-related business that we have experienced
many times before. This fault has not manifested itself for quite a while, since Controls firewalled the MCIS portion of the network on March 30th.
Entry  Mon Jul 13 09:49:52 2009, Damien Gallop, , , 18O4+ tuning to TIGRESS today Picture_19.png
As per our agreed deal last week, today is reserved for Supernanogan tuning to TIGRESS. Development will resume tomorrow.
There was a power bump overnight that knocked out many systems, including OLIS. The ISAC elog mentions something about it here.
It seems that Keerthi restarted the source. (Note to self: Write an ION with brief restart instructions for the Supernanogan.) 18O4+ beam was left on FC6,
Entry  Fri Jul 10 11:47:07 2009, Damien Gallop, Routine, General, 18On+ frequency scans & resonances Picture_18.png
The Supernanogan was restarted this morning, after last night's power bump. 18O4+ on FC6, cooking for about an hour. Looks very good. Keerthi is doing
frequency scans today to find best resonances. Time permitting, he will do this over a range of 18O charge states. He is also developing a dual-mode (MCIS/MWS)
IOS tune. At some point over the weekend (my guess is tomorrow evening), he will open the 17O source gas bottle to the system.
Entry  Fri Jul 10 11:46:55 2009, Damien Gallop, Routine, General, 18On+ frequency scans & resonances Picture_18.png
The Supernanogan was restarted this morning, after last night's power bump. 18O4+ on FC6, cooking for about an hour. Looks very good. Keerthi is doing
frequency scans today to find best resonances. Time permitting, he will do this over a range of 18O charge states. At some point over the weekend (my guess
is tomorrow evening), he will open the 17O source gas bottle to the system.
Entry  Fri Jul 10 09:55:25 2009, Damien Gallop, Routine, General, 18O8+ beam overnight grab.N10241.png
Here is a striptool of 18O8+ beam (magenta trace) last evening from about 18:00 to 22:30 when there was a large power bump coincident with a plane
crash in Richmond last night. Before the trip, beam current was about 20epA on FC6 (normal bias).
Entry  Thu Jul 9 16:07:56 2009, Damien Gallop, Routine, General, 18O8+ frequency scans 6x
Keerthi did some 18On+ frequency scans this morning. He observed 18O8+! I am attempting to repeat it myself now. Reverse bias on FC6.
Peaks at:
13.0277GHz => 1epA (unstable)
Entry  Wed Jul 8 19:51:33 2009, Damien Gallop, Routine, General, 18On+ summary for the day grab.TF3397.pnggrab.fu3402.pnggrab.Tk3406.png
The 18O source gas bottle is online. The ion source was optimized for 18O4+ and kept the same throughout. Emittance scans of each charge state of 18O
were attempted. Visible scans were found for all states up to 6+. At least one more set of scans is desireable. Present beam is 18O4+. Next up: RF frequency
survey with 18On+.
Entry  Wed Jul 8 19:13:15 2009, Damien Gallop, Routine, General, 18O8+ emittance scan grab.Ah3293.pnggrab.ed3302.pnggrab.Nc3298.png
A/q = 2.25 FC6 at reverse bias MB = 736.9G @ 42.9A
Not enough intensity for an emittance scan. Possibly on the edge of A/q=2.3 (23Na10+?).
Entry  Wed Jul 8 19:07:15 2009, Damien Gallop, Routine, General, 18O7+ emittance scan grab.ca3306.png
A/q = 2.57 FC6 = 0.25nA MB = 790.0G @ 46.2A
Not enough intensity for an emittance scan.
Entry  Wed Jul 8 18:57:09 2009, Damien Gallop, Routine, General, 18O6+ emittance scan grab.cb3228.pnggrab.un3232.png
A/q = 3 FC6 = 5.5nA MB = 851.5G @ 50.1A
Entry  Wed Jul 8 18:47:43 2009, Damien Gallop, Routine, General, 18O5+ emittance scan grab.IW3188.pnggrab.kW3192.png
A/q = 3.6 FC6 = 12.5nA MB = 931.8G @ 55.3A
Entry  Wed Jul 8 18:38:21 2009, Damien Gallop, Routine, General, 18O4+ emittance scan grab.Cb3157.pnggrab.wO3161.png
A/q = 4.5 FC6 = 29.5nA MB = 1041.8G @ 62.4A
Entry  Wed Jul 8 18:20:43 2009, Damien Gallop, Routine, General, 18O3+ emittance scan grab.Pc3095.pnggrab.Oi3099.png
A/q = 6 FC6 = 49.5nA MB = 1201.4G @ 73.1A
Entry  Wed Jul 8 18:12:25 2009, Damien Gallop, Routine, General, 18O2+ emittance scan grab.LL3034.pnggrab.Yj3038.png
A/q = 9 FC6 = 50.0nA MB = 1470.8G @ 90.8A
Entry  Wed Jul 8 17:58:02 2009, Damien Gallop, Routine, General, 18O1+ emittance scan grab.QR2996.pnggrab.dm3000.png
Here we go. A/q = 18 FC6 = 141.0nA MB = 2078G @ 130.2A
Entry  Wed Jul 8 17:47:26 2009, Damien Gallop, Routine, General, 18O4+ emittance scans grab.Jj2874.pnggrab.fz2878.pnggrab.ND2931.pnggrab.pH2935.pnggrab.oY2939.png
First up is a check scan of 18O4+. There is a definite vertical offset compared to earlier today. Otherwise, it correlates well enough. The same beam
taken with a greater vertical offset follows, together with the modified emittance panel.
Entry  Wed Jul 8 16:12:51 2009, Damien Gallop, Routine, General, Mass scan in progress grab.rh2790.pngPicture_16.pngPicture_17.png
A mass scan from A/q of zero to 25 is in progress. Data file (large): masscorr_mcis_090708.txt.
The source is optimized for 18O4+. Fishing for 18On+ states and their emittance scans to follow. Attached is one screenshot of the Gabe's Calibrate interface.
I ran it several times with different peak selections from the same data. I entered into the EPICS mass correlation program a best average of the calibrations
Entry  Wed Jul 8 11:52:54 2009, Damien Gallop, Routine, General, Supernanogan development run plan for the remainder of this set 
* 18On+ emittance scans at present ion source settings: complete today.
* 18On+ frequency measurements: Thursday.
* 17O source gas: open end of Thursday.
Entry  Wed Jul 8 10:57:46 2009, Damien Gallop, Routine, General, 18O4+ emittance scans 10x
Tune saved as 090708_1200.snapmcisfc6. I settled on the 15.486GHz
optimal frequency, and tweaked that for effect. Then I ran a few emittance scans. During that process, I noticed that the beam intensity had stepped down
and up a few times. So I tweaked the frequency again to return 30enA on FC6. Note that in this process the beam shifted slightly in the horizontal plane.
Entry  Wed Jul 8 09:34:58 2009, Damien Gallop, Routine, General, 18O4+ frequency optimization 
Starting frequency: 15.7864GHz => 870pA on FC6  Step size: 1MHz. Selected peaks shown. There were many smaller resonances in-between also.
Strong peaks at:
15.8594GHz => 7.5nA
Entry  Wed Jul 8 09:22:07 2009, Damien Gallop, Routine, General, 18O4+ beam growth overnight grab.hD1461.png
After accessing the OLIS cage and opening the 18O source gas valve, I restarted the Supernanogan source last evening around 18:00 ( just to the left
of -15h on the attached stripchart), with the line set up for 18O4+. The beam on FC6 grew nicely overnight. MCIS pressure moved from ~6.5e-8 to ~7.1e-8
Torr since the 18O source gas bottle was opened last evening.
Entry  Tue Jul 7 17:47:14 2009, Damien Gallop, Routine, General, 18On+ beam & emittance 
As noted earlier, we have 17O and 18O source gas attached to the Supernanogan source chamber. Both are valved off presently. The source has been running
for a while. I set it to 18O4+ on background, which gives about 125epA on FC6. Now let's stop the source, open the bottle and try the same again.
I opened the 18O valve just around 18:00. Beam is on now, around 150pA. That's a good sign. It's growing too. Even better. The MCIS tank pressure
Entry  Tue Jul 7 15:43:19 2009, Damien Gallop, Routine, General, ISIS emittance rig tests this morning Picture_11.pngPicture_12.png
Keerthi and I were front and centre doing ISIS emittance rig testing this morning. He ran it, and I tried to find ways to run the data in Matlab afterwards.
Main limitation up there at the ISIS Console is lack of any ssh-enabled terminals. Keerthi's wireless laptop is okay, but this stuff pushes the poor little
thing to the edge. Plus, there were some X display issues on it. He has Matlab installed locally, but it takes a bit of a rocket scientist to run it, and
Entry  Mon Jul 6 17:34:24 2009, Damien Gallop, Routine, General, 18O background studies 6x
Well... my browser blew away just before I submitted version one of this entry. Let's try again.
Keerthi changed the tune this morning to 10kV on the MCIS bias in order to allow the full throw of the Enzel lens power supply. (Remember, for
the moment the panel displays twice what the physical power supply is actually delivering, because it is a 10kV supply, whereas the control system expects
Entry  Mon Jul 6 10:57:08 2009, Damien Gallop, Routine, General, Beam stability versus temperature over weekend Picture_4.png
We had 16O3+ on FC6 on Friday. An IOSIOC reboot occurred mid-afternoon Friday unfortunately. Operators restored beam at about 06:00 on Saturday. Beam
came back fine. I requested FC3 in at 18:00 Saturday to get some temperature correlation with total beam. Maybe there is a correlation, but a longer stretch
is needed. Something stopped at 18:00 on Sunday. Keerthi told me this morning that he found steerers off, and switching them on restored beam instantly.
Entry  Fri Jul 3 10:29:15 2009, Damien Gallop, Routine, General, RF frequency scans versus each charge state of 16O cont'd. grab.Cr7150.pnggrab.yi7257.pnggrab.vt7264.pnggrab.vP7271.png
16O2+ beam on FC6 = 10nA as before. Move to 16O3+ A/q = 5.33...
A frequency scan between 13 & 14GHz. I panned closer around two peaks at 13.11 and 13.12GHz. Best frequency so far is 13.1321GHz, which provides
a reasonably stable 150pA of 16O3+.
Entry  Fri Jul 3 10:03:11 2009, Damien Gallop, Routine, General, Overnight beam stability on FC3 grab.lB3687.pnggrab.w13197.pngmcis_fc3_090703.datiosfc3_fc6_halltemp.txt
Here are some pics and data from total MCIS beam on FC3 overnight. A bit inconclusive, but there may be a temperature correlation.
Entry  Thu Jul 2 16:55:04 2009, Damien Gallop, Routine, General, RF frequency scans versus each charge state of 16O 7x
Let's take a look at varying frequency versus beam current for 16O2+. Starting RF values shown below. FC6 = 1.09enA.
What I did: Pan RF frequency between about 12.5GHz and 14GHz. Plasma seemed to extinguish at a frequency under 13GHz.
What I found: Two peaks on the low side, right around 13GHz.
Entry  Thu Jul 2 11:58:18 2009, Damien Gallop, Routine, General, Supernanogan development in progress Picture_29.pnggrab.x14914.pnggrab.C15389.png
Happy Canada Day!
I noticed a long-term trend in beam intensity. I have every reason to believe that the source itself is rock-solid. I think it is temperature variation
affecting the Philtek power suply on the separator magnet. What bothers me is that the stability program appears to not be compensating for this. I am
Entry  Tue Jun 30 17:39:13 2009, Damien Gallop, Routine, General, Compare 16O2+ beam from start of run to today 6x
There seemed to be some small change to the beam over the week of TACTIC running. I would like to poke around a bit. The emittance plots suggest some
vertical movement at least. The two plots are the before (emittance)
and after (emittance).
Entry  Tue Jun 30 17:16:25 2009, Damien Gallop, Routine, General, 16O2+ emittance scans with slits open 6x
First, with upstream slits opened, then with both open. Original slit setting was 1mm. Finally, restore slits to 1mm and see if it reproduces. It does.
Entry  Tue Jun 30 10:56:26 2009, Damien Gallop, Routine, General, 16O2+ emittance scans 6x
The first emittance scan sort of got interrupted; it auto-restarted just before the previous scan had finished. I thought the resulting plot was somewhat
interesting. The emittance isn't half-bad either. A better scan follows. TACTIC took beam again for a while this afternoon to shake down a timing discrepancy.
We got it back around 4pm. One more emittance scan for good measure.
Entry  Tue Jun 30 10:30:17 2009, Damien Gallop, Routine, General, Initial development setup 
Setup teething pains... The Start button on the emittance panel worked this time. But ICR called, requesting a few minutes more for Marco. No problem.
When I went to restart the scan, the button no longer worked. Restarting X11 made no difference. However, there is a significant update available for X11,
so I am installing it now. I perceive that it works, yes, significantly faster than its predecessor. Good, all good.
Entry  Tue Jun 30 09:33:00 2009, Damien Gallop, Routine, General, Supernanogan Development begins today for two weeks 
Supernanogan development starts today. The TACTIC run, which ended around 08:30 today, appears to have been a success. TACTIC used our beam for setup
and pilot, then took 8Li from downstairs. Marco is doing some EOB checks now. We will begin at 10:00. First part of our run plan will be to compare the
present 16O2+ beam with how it looked when we started, and identify what might have changed.
Entry  Mon Jun 29 10:35:35 2009, Damien Gallop, Routine, General, 16O2+ pilot beam to TACTIC in progress Picture_23_09-22-33.pngPicture_23.pngPicture_24.png
We handed over a 16O2+ beam on Wednesday morning to Sophia for TACTIC setup. On our side, everything went well. TACTIC switched to RIB on Saturday night.
See ISAC elog entry. We remain on standby
for pilot beam. Schedule switched to development tomorrow morning. Attached is a stripchart of our beam for the last several hours. As good as it gets!
Entry  Wed Jun 24 10:27:23 2009, Damien Gallop, Routine, General, 16O2+ tune ready for Sophia and Marco Picture_22.pngPicture_23.pnggrab.s21695.pnggrab.H11995.png
See ISAC elog entry today.  Keerthi
developed a dual-mode tune last night, so that we can run the MWS at will if so desired. Save file: 090624_0930.snapmcisfc6.
Emittance scans done. Overnight FC6 also attached. Sophia took the beam at 10:00.
Entry  Tue Jun 23 18:04:30 2009, Damien Gallop, Routine, General, MCIS HV conditioning to 20KV grab.Vd9281.png
Supernanogan bias for this run is 16.32KV. After we were finished with source tuning, etc., we conditioned up to 20KV. Then beam was returned and 16O2+
tuned saved as 090623_1730.snapmcisfc6. Next step: Prepare MWS for dual operation. Source open now for source gas installation. Then Keerthi will
develop a daul-mode tune, where the B1A bender only need be switched on or off to run either the MCIS or MWS source.
Entry  Tue Jun 23 16:48:00 2009, Damien Gallop, Routine, General, 16O2+ on FC6 after source tuning grab.IW8732.pnggrab.wS8740.pnggrab.mb8690.pnggrab.ON8795.png
After a first round of source and line tuning for good current with minimum RF power, we have about 8nA of 16O2+ on FC6. Here is an emittance scan of
that. Present RF settings are 15.438GHz and -1.0dB with less than 1W of RF power. Bias is 16.32KV. Let's do some bias conditioning for a bit.
Entry  Tue Jun 23 15:02:38 2009, Damien Gallop, Routine, General, 16O2+ on FC6 grab.wE8003.pnggrab.YK8019.pnggrab.HH8254.pnggrab.WH8272.pnggrab.ly8245.png
We now have about 80nA of 16O2+, using the same source parameters as before. Keep a watch for a while, then tune the source to match user's needs, somewhere
in the 10nA range.
Here is a stripchart of the 16O2+ beam for the last half-hour or so., and also the stripchart of it juxtaposed with 16O7+ earlier. Also a first
Entry  Tue Jun 23 10:33:43 2009, Damien Gallop, Routine, General, Effects of RF on charge state grab.aS7166.pnggrab.WZ7540.pnggrab.Ku7550.pnggrab.Pv7570.png
Today is the last day of this set of Supernanogan Development. The source ran at 16KV overnight, in anticipation of 16O2+ delivery later today. I expected
more bias sparking, but it appears that it sparked off only once. So I will condition at a higher bias later today. Meanwhile, the operators reported touching
up the tune with the magnet and the RF. Perhaps we are seeing some temperature effect on the source, so I will be looking at effects of RF on 16O7+ for
Entry  Mon Jun 22 20:28:37 2009, Damien Gallop, Routine, General, Preparations for 16O2+ delivery 6x
In anticipation of 16O2+ delivery mid-week, we checked 16O2+ production from the Supernanogan source. No problem. We did have to use the tightest slit
settings to achieve a low enough current for the user. Here are emittance scans, normal and with our test booster amplifier inline respectively. Subsequently
we set up the line to match into the RFQ. Bias is at 16.32KV. Then we returned the mass selection to 16O7+ for the night. A final emittance scan of 16O7+
Entry  Mon Jun 22 16:00:04 2009, Damien Gallop, Routine, General, Emittance thoughts and other matters 7x
An emittance scan of the 16O7+ beam follows. Also, a stripchart of the same beam on FC6 overnight. Keerthi did some studies over the weekend. He found
that the characteristics of the amplifiers behind FC6 and the emittance rig cup differ significantly. That's disconcerting. We did a visual this morning,
and confirmed that the amplifiers are identical VME modules in the same crate. He believes it's a scaling thing. We will test again with a current source
Entry  Fri Jun 19 20:15:19 2009, Damien Gallop, Routine, General, Summary of 16On+ emittance scans 
Here is a list of 16On+ emittance scans for today. Although IOSIOC got rebooted, restored tune was identical and trouble-free, and RF was untouched.
Save file: 090619_0859.snapmcisfc6. Emittance values: pi-mm-mrad
at 39%, 63%, 86% and 90% respectively. Here we go.
Entry  Fri Jun 19 11:59:49 2009, Damien Gallop, Routine, General, 16On+ emittance scans continue 18x
Keerthi developed a nice 16O7+ beam to FC6 last night. Beam current is about 3nA presently. Here is the first emittance scan from 11:05 today. A little
spotty, but it's there. Higher resolution scan at 13:58 follows.
The third plot at 16:12 is 16O6+.
Entry  Thu Jun 18 09:38:52 2009, Damien Gallop, Routine, General, Check Supernanogan beam after IOC reboot yesterday 15x
As mentioned before, IOSIOC was rebooted yesterday afternoon to unfreeze the emittance rig panel. It cost us our tune, which unfortunately wasn't saved
very well. Lesson learned: Save often. I will run a mass scan now and check the mass correlations calibration. Then I will pick up with some 16On+ emittance
scans. Keerthi was here until late last night working with the beam also. He will have some results for sure.
Entry  Wed Jun 17 17:01:07 2009, Damien Gallop, Routine, General, 16On+ emittance scans 
A series of 16On+ emittance scans. Benchmark scan of 16O5+ matched well with same scan done this morning. Subsequent scans beginning with 16O1+ were
thwarted by an IOSIOC seizure in the emittance rig EPICS panel, and an IOC reboot was required. ICR restored last saved DRAGON tune. So far, so good. Ah,
well, not so fast. I have to go fishing for beam on FC6. This may take a while... That's it for today.
Entry  Wed Jun 17 10:14:57 2009, Damien Gallop, Routine, General, 16O5+ on FC6 overnight 6x
The 16O5+ beam stayed up OK overnight. ICR took some emittance
scans this morning. They look interesting. A finer resolution scan is in progress presently. Goals today:
1. Comprehensive mass scan to A/q=100
Entry  Tue Jun 16 16:47:02 2009, Damien Gallop, Routine, General, Mass scan around 16O5+ grab.W16564.pnggrab.W24269.pnggrab.x24327.pnggrab.w24262.png
Keerthi suggested using 16O5+ for optimizing the source. I did a tight mass scan in that area, and 16O5+ is clearly visible. I will use it for some source
tweaking. Also, I used Gabe's calibration program to slightly adjust the values of the two constants. There are some 10nA of 16O5+ on FC6 presently. Final
settings for today, etc. are attached below.
Entry  Mon Jun 15 17:49:23 2009, Damien Gallop, Routine, General, 84Kr charge states begun 
We began looking at 84Kr this weekend. Keerthi had 84Kr19+ on FC6 this morning, which I was able to tweak up from ~300epA to about 600epA. Not bad! This
evening it is down to 100pA at best. I think there is a correlation of multi-charge production and room temperature. (It's warm today.) Keerthi noticed
tat an entire mass scan this afternoon was suppressed, where I had a solid scan earlier, the two taken the same way. Let's see what happens to FC6 overnight.
    Reply  Tue Jun 16 12:10:17 2009, Damien Gallop, Routine, General, 84Kr charge states begun grab.c14389.pnggrab.Q14911.pnggrab.T15712.pnggrab.F15724.png


    
        
            Damien Gallop wrote:
        
        
            
            We began looking at 84Kr this weekend. Keerthi had 84Kr19+ on FC6 this morning, which I was able to tweak
Entry  Fri Jun 12 14:24:49 2009, Damien Gallop, Routine, General, 17O3+ beam at optimized RF grab.Q22311.pnggrab.Z22325.pnggrab.F22387.png
A comment about RF power came up at the presentation this morning. Intense X-rays can be produced not only at the peak efficiency and output of the RF
amplifier but also as a function of other parameters including source gas pressure, isotope(s), whatever you can think of. I set the RF at a mid-level
power, with power setpoint at 0dB and adjusted the RF for optimal current on FC6. This occurred at 13.0306GHz with 35W power. About 6nA of beam. Take a
Entry  Fri Jun 12 14:12:04 2009, Damien Gallop, Routine, General, OLIS & Supernanogan Facilities presentation 
Presentation this morning in Auditorium. Players:
Keerthi: science
Geoff: engineering
Entry  Thu Jun 11 12:10:22 2009, Damien Gallop, Routine, General, Supernanogan status 
Pumping went well overnight. TP3 turned on around noon. Issues with Kepco communications.
Entry  Wed Jun 10 18:48:53 2009, Damien Gallop, Routine, General, Krypton source gas fitted 
Krypton source gas teed directly into ion source. A Nupro valve and tee also added for 17O line. At present, the 17O gas bottle valve is closed. The
Kr bottle has an integrated leak, so this bottle is opened to the system now. Pumping in progress. Pressure is already <3e-7 Torr. I will restart the
source shortly.
Entry  Wed Jun 10 17:49:40 2009, Damien Gallop, Routine, General, Beam to RFQ 
We handed over the beam to Sophia for testing Rick's new tune. Although there are RF issues at the RFQ presently, her feedback to the operators is so
far, so good. TBC tomorrow morning. Right now, we will open the OLIS cage and install a couple of source gases in preparation for our presentation on Friday.
Entry  Wed Jun 10 11:22:59 2009, Damien Gallop, Routine, General, Supernanogan development mass scans grab.t27875.pnggrab.R27900.pnggrab.H27444.png
Main event this morning so far: mass scans and post-scan analysis using Gabe's tools. We have a pretty good recipe now. Tight scan to mass 20 in progress.
Later... good scan. Geoff and I did a dry run of our presentations for Friday morning. We used the Auditorium computers, etc. After some small teething
pains, everything went well, including a cold start-up of the source. The 17O3+ emittance scan was taken quickly. Pretty good outcome anyway. The mass
Entry  Tue Jun 9 20:49:32 2009, Damien Gallop, Routine, General, Supernanogan RF & IOS slits grab.T18854.pnggrab.s18900.png
I have been testing various RF power settings for cold starts and beam stability. No surprise, the best tuner setting is approximately midway at about
58%. Different slit selections tested. Emittance scans in progress. Done.
Entry  Tue Jun 9 16:53:55 2009, Damien Gallop, Routine, General, Supernanogan development in progress 
Keerthi started the Supernanogan source today. His primary goal was to test out Rick's theoretical tune calculations. He was ecstatic with the results.
Rick's table gives a tentitive value for the Einzel lens. In fact the ideal value is at or even higher than the bias voltage. However, Keerthi experieced
sparkdowns at those voltages. Rick's calculation gives a reasonable number for better than 50% transmission between MCIS:FC0 and IOS:FC3. The Enzel lens
Entry  Mon Jun 8 09:31:39 2009, Damien Gallop, Routine, General, Emittance scan of 18O beam from MWS 
The TIGRESS run ended this morning. Supernanogan Development begins now for two weeks. Begin an 18O1+ emittance scan and also take some fast FC6 current
measurements before we switch over.
Entry  Thu Jun 4 10:46:37 2009, Damien Gallop, Routine, General, 18O source operation overnight 
The MWS delivered 18O overnight, mostly onto FC6. Sophia complained about source stability this morning. It definitely could be improved. Yesterday Keerthi
did some online tweaking of the RF power for stability, with little improvement. The IOS pressure today is about 2e-6 Torr, so I believe the 18O pressure
is too high for good operation, although the brightness is great. The base pressure is about 4e-7 Torr. Tuning is in progress. Given an opportunity, I
Entry  Wed Jun 3 16:17:51 2009, Damien Gallop, Routine, General, MWS started for 18O1+ production to TIGRESS 
A couple of weeks of 17O3+ to DRAGON ended yesterday with a photo finish. Supernanogan went off at 10:00. Preparations for 18O began. Main event for
yesterday: Replace IOS:TP7. Edi Dalla Valle reported that he had just received a V550 with Conflat flange. "Our timing was perfect." It is working
well. The system was under vacuum again by around noon, and pumped overnight. This morning IG1 was ~5e-7 Torr and IG4 was ~2e-7 Torr, where those two gauges
Entry  Fri May 22 15:03:55 2009, Damien Gallop, Routine, General, Temporary fix on IOS:TP7 
Vacuum Group applied a temporary fix to the lower body seal on IOS:TP7, which we found last night to be leaking. Edi tells me that similar seals have
failed before. It's an O-ring, not a metal seal. The fix now was to marinate the outside seam with silicon grease and wrap with Teflon tape. We'll see
how that improves the backing line after a while.
Entry  Fri May 22 12:31:36 2009, Raymond Dubé, , , Test 
Hello world
Entry  Fri May 22 10:50:06 2009, Damien Gallop, Routine, General, MCIS online with 17O3+ on FC6 
The previous 18O4+/8+ run to TUDA-II finished midday yesterday. OLIS was prepared for 17O delivery from the Supernanogan source. Leak checking was done
last night. The big offender was a failing metal seal on IOS:TP7. The pump will have to be replaced. Meanwhile the pressure is sufficient for 20nA of 17O3+
with 2.5mm (middle selection) apertures inserted. Present agreement is to leave TP7 as-is for this run.
Entry  Thu May 21 16:23:37 2009, Damien Gallop, Routine, General, 18O4+/8+ to TUDA-II declared done around noon 
End of run diagnostics done. See ISAC elog. Supernanogan cart is already installed and at high vacuum. Prepare to run 17O from Sgan sometime over the
weekend. Today's agenda:
1. Close 18O bottle and gas valves.
Entry  Fri May 15 14:12:45 2009, Geoff Wight, , , 1st test 
test
Entry  Thu May 14 12:02:09 2009, Damien Gallop, Routine, General, Testing 2 
My first OLIS elog entry.
Entry  Thu May 14 11:07:33 2009, Hossein Rafighi, , , Test 