OLIS Logbook General
  General  Not logged in ELOG logo
Message ID: 266     Entry time: Mon May 10 16:42:55 2010
Author: Damien Gallop 
Type:  
Category:  
Subject: Supernanogan development 

By agreement, the source came down this morning for continuing Supernanogan development. Main event: leak detecting.

Later... Robert and Tim lead leak detectors. Synopsis: A minute leak at waveguide flange on plasma chamber. We decided to seal it with a drop of vacuum sealant. Worked like a jet. Once Supernanogan beams are done for this beam schedule, we will remove the waveguide and re-machine and weld the flange. We also believe there is a minute leak at the bellows joining MCIS and IOS. TBC.