Starting frequency: 15.7864GHz => 870pA on FC6 Step size: 1MHz. Selected peaks shown. There were many smaller resonances in-between also.
Strong peaks at:
15.8594GHz => 7.5nA
15.9834GHz => 1.3nA
16.0354GHz => 1.3nA
16.107GHz => 1.5nA
16.183GHz => 0.9nA
16.247GHz => 1.4nA
16.284GHz => plasma extinguished
16.248GHz => plasma re-ignited
15.860GHz => 7.5nA
15.685GHz => 3.5nA
15.518GHz => 2.5nA
15.486GHz => 27.5nA
15.479GHz => 4.3nA
15.277GHz => 2.8nA
15.130GHz => 3.7nA
15.035GHz => 6.2nA
14.903GHz => 3.8nA
14.799GHz => 2.6nA
14.763GHz => 11.8nA
14.554GHz => 8.8nA
14.455GHz => 4.2nA
13.588GHz => 1.1nA
13.398GHz => 3.0nA
13.281GHz => 2.7nA
13.223GHz => 7mA (unstable)
13.153GHz => 7.5nA (unstable)
13.061GHz => 10.0nA (unstable)
13.019GHz => 40.0nA
13.002GHz => 50.0nA (unstable)
12.986GHz => plasma extinguished
13.089GHz => plasma re-ignited
15.4798GHz => 30.0nA |