M9sol Logbooks Solenoid Daily log
  Solenoid logbook  ELOG logo
Entry  Fri Nov 12 16:54:50 2010, Doug Preddy, Normal Running, Solenoid ramped up 
Entry  Thu Nov 11 15:46:40 2010, Doug Preddy, Other, switched to parallel cold return 
Entry  Mon Aug 9 14:27:12 2010, Doug Preddy, Shut Down, Helium plant shut down 
Entry  Mon Jun 7 09:24:47 2010, Doug Preddy, Quench Recovery, started flow to power leads 
Entry  Tue May 18 15:04:36 2010, Kevin Trithardt, Maintenance, Solenoid ramping up 
Entry  Thu May 13 14:37:13 2010, Doug Preddy, Quench Recovery, switching to series mode. 
Entry  Thu May 13 07:39:55 2010, Doug Preddy, Quench Recovery, solenoid quench last night 
Entry  Mon May 3 07:49:54 2010, Doug Preddy, Quench Recovery, Solenoid quench Saturday 
Entry  Fri Apr 9 16:07:28 2010, Doug Preddy, Start Up, flow to power leads started 
Entry  Fri Apr 9 07:34:55 2010, Doug Preddy, Quench Recovery, switched to parallel cold return 
Entry  Thu Apr 1 11:57:55 2010, Doug Preddy, Start Up, started flow to power leads 
Entry  Mon Mar 29 09:25:52 2010, Kevin Trithardt, Start Up, Started cool down this morning 
Entry  Wed Mar 24 08:30:33 2010, Doug Preddy, Start Up, Start up 
Entry  Mon Oct 5 11:54:58 2009, Doug Preddy, Normal Running, Switched TIC121 into auto mode 
Entry  Tue Jul 14 15:28:36 2009, Doug Preddy, Quench Recovery, Solenoid ramped up 
Entry  Fri Jul 10 01:10:59 2009, Doug Preddy, Quench Recovery, switch to parallel warm return 
Entry  Fri Jul 10 00:34:03 2009, Doug Preddy, Quench Recovery, solewnoid quench due to power bump 
Entry  Wed May 27 15:01:34 2009, Doug Preddy, Quench Recovery, power leads 
Entry  Wed May 27 13:37:22 2009, Doug Preddy, Quench Recovery, switch to series mode 
Entry  Wed May 27 08:06:00 2009, Doug Preddy, Quench Recovery, Solenoid quenched at 5:00 
Entry  Wed Dec 10 15:44:58 2008, Doug Preddy, Maintenance, Repairs to solenoid power supply 
Entry  Wed Dec 10 15:41:04 2008, Doug Preddy, Shut Down, shuttting down solenoid 
Entry  Wed Nov 5 16:33:52 2008, Doug Preddy, Normal Running, sbplc light out 
Entry  Sun Oct 5 18:54:27 2008, Doug Preddy, Quench Recovery, Solenoid Quench ~16:30 
Entry  Sun Oct 5 11:12:48 2008, Doug Preddy, Normal Running, M9B:V1 interlocks and a IOC crash 
Entry  Fri Sep 26 09:50:18 2008, Doug Preddy, Quench Recovery, started flow in parallel cold return mode 
Entry  Fri Sep 26 09:45:18 2008, Doug Preddy, Quench Recovery, Solenoid quenched at 7:50 
Entry  Fri Sep 26 09:44:25 2008, Doug Preddy, Maintenance, Water flow interlock restored 
Entry  Tue Sep 9 15:04:23 2008, Doug Preddy, Maintenance, Jumpered interlock for diff pump water flow 
Entry  Thu Sep 4 10:02:55 2008, Doug Preddy, Normal Running, ramping down solenoid 
Entry  Sun Aug 24 06:45:14 2008, Doug Preddy, Quench Recovery, switch to series mode 
Entry  Sat Aug 23 17:02:38 2008, Doug Preddy, Quench Recovery, Solenoid quenched 
Entry  Sat Jul 26 01:29:21 2008, Doug Preddy, Quench Recovery, power leads 
Entry  Sat Jul 26 01:06:04 2008, Doug Preddy, Quench Recovery, Refrigerator in series mode 
Entry  Fri Jul 25 21:48:15 2008, Doug Preddy, Quench Recovery, another quench 
Entry  Thu Jul 24 16:28:50 2008, Doug Preddy, Quench Recovery, power bump 
Entry  Tue Jul 15 08:47:13 2008, Doug Preddy, Normal Running, Screen grab of normal running july_15_08_0841.jpgjuly_15_08_0846.jpg
Entry  Sun Jul 13 20:17:24 2008, Doug Preddy, Other, Helium refrigerator problems 
Entry  Mon Apr 28 09:03:22 2008, Doug Preddy, Normal Running, power leads warmed during weekend 
Entry  Thu Apr 17 13:52:25 2008, Doug Preddy, Start Up, switched to series mode at 9:30 this morning 
Entry  Wed Apr 16 16:51:16 2008, Doug Preddy, Start Up, switched to parallel cold return 
Entry  Wed Apr 16 15:15:44 2008, Doug Preddy, Start Up, refrigerator started  
Entry  Wed Apr 16 15:12:01 2008, Doug Preddy, Normal Running, graphs to load 
Entry  Tue Apr 1 15:17:06 2008, Doug Preddy, Start Up, Starting up vacuum systems 
Entry  Mon Dec 3 14:59:58 2007, Doug Preddy, Quench Recovery, Not really a quench recovery, But... 
Entry  Wed Nov 28 15:07:08 2007, Kevin Trithardt, Other, power lead regeneration 
Entry  Tue Nov 27 21:02:08 2007, Doug Preddy, Normal Running, power lead ripples 
Entry  Mon Nov 26 09:45:43 2007, Doug Preddy, Normal Running, power lead problems 
Entry  Fri Nov 23 08:41:45 2007, Doug Preddy, Normal Running, screen grab of powerlead temps Capture.jpg
Entry  Fri Nov 23 08:35:37 2007, Doug Preddy, Normal Running, power lead problems 
Entry  Mon Nov 19 04:30:47 2007, Doug Preddy, Quench Recovery, switched to series mode 
Entry  Mon Nov 19 02:58:44 2007, Doug Preddy, Quench Recovery, Solenoid quenched on power lead over temperature 
Entry  Fri Nov 9 18:56:20 2007, Doug Preddy, Maintenance, System Ready to Run 
Entry  Fri Nov 9 16:24:33 2007, Doug Preddy, Maintenance, 2APLC Died 
Entry  Fri Nov 9 14:50:03 2007, Doug Preddy, Quench Recovery, Solenoid cold 
Entry  Fri Nov 9 07:37:44 2007, Doug Preddy, Quench Recovery, switched to series mode 
Entry  Thu Nov 8 09:28:53 2007, Doug Preddy, Quench Recovery, started compressor 
Entry  Wed Oct 24 12:04:06 2007, Doug Preddy, Maintenance, power lead and cryopump regeneration 
Entry  Tue Oct 9 13:16:44 2007, Doug Preddy, Quench Recovery, switched to series mode 
Entry  Tue Oct 9 12:58:22 2007, Doug Preddy, Quench Recovery, Solenoid Quench 2 
Entry  Fri Oct 5 13:25:41 2007, Doug Preddy, Quench Recovery, funny graph  Capture.jpg
Entry  Fri Oct 5 10:25:43 2007, Doug Preddy, Quench Recovery, Unknown quench 2 
Entry  Tue Oct 2 13:02:37 2007, Doug Preddy, Normal Running, PLC problems 
Entry  Thu Sep 27 07:41:15 2007, Doug Preddy, Start Up, Solenoid cold 
Entry  Wed Sep 26 08:52:46 2007, Doug Preddy, Start Up, switched to parallel cold return 
Entry  Tue Sep 25 07:34:04 2007, Doug Preddy, Start Up, PIC229 to 11 bar 
Entry  Mon Sep 24 15:08:41 2007, Doug Preddy, Start Up, Started cool down this morning 
Entry  Wed Sep 19 20:53:18 2007, Doug Preddy, Maintenance, More diff pump news 
Entry  Tue Sep 18 18:48:11 2007, Curtis Ballard, Maintenance, cold box leak check 
Entry  Fri Sep 14 12:44:52 2007, Doug Preddy, Start Up, started compressor 
Entry  Wed Sep 12 12:01:02 2007, Doug Preddy, Maintenance, regenerated adsorber 
Entry  Tue Aug 14 12:55:12 2007, Doug Preddy, Normal Running, Strip tool saves 
Entry  Tue Aug 14 10:15:22 2007, Doug Preddy, Maintenance, Solenoid ramped down 
Entry  Mon Aug 6 08:41:31 2007, Doug Preddy, Quench Recovery, Cold box trip at 6:00 
Entry  Tue Jul 31 07:53:57 2007, Kevin Trithardt, Normal Running, cycled power leads 
Entry  Sun Jul 29 04:58:27 2007, Doug Preddy, Quench Recovery, Energizing solenoid 
Entry  Sat Jul 28 22:30:13 2007, Doug Preddy, Quench Recovery, quench again 
Entry  Sat Jul 28 15:45:17 2007, Doug Preddy, Quench Recovery, quench recovery 
Entry  Thu Jul 5 11:01:47 2007, Kevin Trithardt, Other, Current lead warm up 
Entry  Thu Jul 5 03:04:50 2007, Doug Preddy, Normal Running, Power lead problems 
Entry  Wed Jul 4 11:13:12 2007, Doug Preddy, Quench Recovery, test 
Entry  Sun Jul 1 16:09:37 2007, Doug Preddy, Normal Running, M9B:DP2 tripped off  
Entry  Tue Jun 19 21:15:41 2007, Doug Preddy, Quench Recovery, Today's quench 
Entry  Sat Jun 16 15:05:03 2007, Doug Preddy, Normal Running, Solenoid power lead temp problem 
Entry  Thu Jun 14 00:10:10 2007, Doug Preddy, Quench Recovery, recovering from earlier quench 
Entry  Tue Jun 12 12:48:25 2007, Doug Preddy, Maintenance, added one bottle UHP helium to system 
Entry  Thu May 31 11:51:49 2007, Doug Preddy, Quench Recovery, Switched to series mode 
Entry  Thu May 31 07:11:05 2007, Doug Preddy, Quench Recovery, switched to parallel cold return 
Entry  Wed May 30 11:27:32 2007, Doug Preddy, Quench Recovery, Problems recovering 
Entry  Wed May 30 08:38:38 2007, Doug Preddy, Quench Recovery, Solenoid quenched this morning 
Entry  Wed May 16 10:02:35 2007, Doug Preddy, Maintenance, warming up power leads 
Entry  Wed May 2 16:28:16 2007, Doug Preddy, Normal Running, Energizing solenoid to 500 amps 
Entry  Mon Apr 30 09:30:26 2007, Doug Preddy, Normal Running, problems over weekend 
Entry  Fri Apr 27 10:32:07 2007, Doug Preddy, Quench Recovery, Reset quench relay logic box 
Entry  Fri Apr 27 10:16:44 2007, Kevin Trithardt, Quench Recovery, Test 
Entry  Fri Apr 27 10:10:07 2007, Doug Preddy, Normal Running, Solenoid Cold 
Entry  Tue Apr 24 10:21:49 2007, Doug Preddy, Start Up, Started flow to turbines 
Entry  Mon Apr 23 16:31:02 2007, Doug Preddy, Start Up, Started compressor 
Entry  Fri Apr 20 12:15:12 2007, Doug Preddy, Start Up, remote PLC switch 
Entry  Thu Apr 19 15:18:25 2007, Doug Preddy, Start Up, preparing to start the refrigerator 
Entry  Mon Mar 5 14:59:41 2007, Doug Preddy, Maintenance, Password 
Entry  Fri Jan 26 15:10:37 2007, Doug Preddy, Maintenance, new control computer installed 
Entry  Tue Nov 28 10:32:04 2006, Doug Preddy, Quench Recovery, recovering after looong power outage 
Entry  Wed Nov 15 17:05:49 2006, Willy Andersson, Quench Recovery, powerleads cold, energizing solenoid 
Entry  Wed Nov 15 13:56:00 2006, Doug Preddy, Quench Recovery, switch to series mode 
Entry  Wed Nov 15 11:09:28 2006, Doug Preddy, Quench Recovery, Compressor tripped off 
Entry  Tue Nov 7 10:35:32 2006, Doug Preddy, Normal Running, Maintenance day 
Entry  Fri Nov 3 12:09:51 2006, Doug Preddy, Normal Running, Fine tuning 
Entry  Tue Oct 31 08:37:34 2006, Doug Preddy, Quench Recovery, Energizing solenoid 
Entry  Tue Oct 31 05:36:14 2006, Doug Preddy, Quench Recovery, switch to series mode 
Entry  Tue Oct 31 03:52:29 2006, Doug Preddy, Quench Recovery, power lead quench at 2:30 this morning 
Entry  Thu Oct 26 14:14:57 2006, Doug Preddy, Quench Recovery, power lead quench 
Entry  Thu Oct 26 11:45:22 2006, Doug Preddy, Quench Recovery, Solenoid cold 
Entry  Thu Oct 26 08:18:10 2006, Doug Preddy, Quench Recovery, switched to series mode 
Entry  Thu Oct 26 04:34:15 2006, Willy Andersson, Quench Recovery, Still in // cold return mode. 
Entry  Thu Oct 26 04:27:31 2006, Willy Andersson, Quench Recovery, Powerlead overtemp 
Entry  Sun Oct 15 07:09:41 2006, Other, Normal Running, cryopump bcp2 trip 
Entry  Thu Oct 12 19:54:10 2006, Willy Andersson, Quench Recovery, Energized solenoid. 
    Reply  Fri Oct 13 00:13:57 2006, Experimentor, Quench Recovery, Energized solenoid. 
Entry  Thu Oct 12 11:53:04 2006, Willy Andersson, Quench Recovery, Compressor trip, 09:50 this morning. 
Entry  Thu Oct 5 14:53:54 2006, Doug Preddy, Start Up, Switched to series mode 
Entry  Thu Oct 5 11:51:53 2006, Doug Preddy, Start Up, Adde 2 bottles UHP Helium 
Entry  Thu Oct 5 10:26:26 2006, Doug Preddy, Start Up, switched to parallel cold return 
Entry  Wed Oct 4 18:10:18 2006, Willy Andersson, Start Up, Quick check on system 
Entry  Wed Oct 4 07:29:04 2006, Doug Preddy, Start Up, Starting cool down 
Entry  Thu Aug 17 19:45:27 2006, Willy Andersson, Quench Recovery, switch to series cooling 
Entry  Thu Aug 17 08:04:44 2006, Doug Preddy, Quench Recovery, Solenoid tripped at about 3:00 this morning 
Entry  Tue Aug 15 15:39:27 2006, Willy Andersson, Quench Recovery, switched to parallel cold return 
Entry  Tue Aug 15 08:45:56 2006, Doug Preddy, Quench Recovery, restarted the compressor 
Entry  Thu Aug 10 20:26:09 2006, Willy Andersson, Quench Recovery, solenoid energized 
Entry  Thu Aug 10 16:33:11 2006, Willy Andersson, Quench Recovery, Flow to solenoid tripped on powerlead temperature. 
Entry  Thu Aug 10 08:33:44 2006, Doug Preddy, Normal Running, Running low on helium 
Entry  Wed Aug 9 07:50:49 2006, Doug Preddy, Quench Recovery, Switched to series mode. 
Entry  Wed Aug 9 06:59:43 2006, Willy Andersson, Quench Recovery, more // cold return stuff 
Entry  Wed Aug 9 06:44:58 2006, Willy Andersson, Quench Recovery, // cold mode cooling continues. 
Entry  Tue Aug 8 07:27:49 2006, Doug Preddy, Quench Recovery, Solenoid Quench at about 6:00 this morning 
Entry  Sat Jul 29 09:38:06 2006, Doug Preddy, Quench Recovery, power leads cooled 
Entry  Sat Jul 29 05:30:28 2006, Doug Preddy, Quench Recovery, switched to series mode 
Entry  Fri Jul 28 20:39:40 2006, Doug Preddy, Quench Recovery, Restarting refrigerator 
Entry  Sat Jul 22 06:34:14 2006, Experimentor, Quench Recovery, looking good 
Entry  Fri Jul 21 23:36:21 2006, Doug Preddy, Quench Recovery, Final cooldown problems 
Entry  Fri Jul 21 17:18:19 2006, Willy Andersson, Quench Recovery, Opened HIC142 fully open 
Entry  Fri Jul 21 14:08:04 2006, Doug Preddy, Quench Recovery, switch to series mode 
Entry  Fri Jul 21 07:39:37 2006, Doug Preddy, Quench Recovery, Cool down continues 
Entry  Thu Jul 20 13:34:26 2006, Willy Andersson, Quench Recovery, cold return mode continues... 
Entry  Thu Jul 20 13:27:21 2006, Willy Andersson, Quench Recovery, cold return mode continues... 
Entry  Thu Jul 20 13:21:57 2006, Willy Andersson, Quench Recovery, started // warm return flow. 
Entry  Thu Jul 20 11:01:09 2006, Willy Andersson, Quench Recovery, Opened up warm return valves CV151 and CV153 
Entry  Thu Jul 20 08:18:31 2006, Doug Preddy, Quench Recovery, T1 started 
Entry  Thu Jul 20 02:59:06 2006, Doug Preddy, Quench Recovery, T1 still not starting 
Entry  Thu Jul 20 00:52:13 2006, Doug Preddy, Quench Recovery, T1 frozen 
Entry  Thu Jul 20 00:25:16 2006, Doug Preddy, Quench Recovery, Solenoid quenched @ 11:15 
Entry  Thu Jul 6 15:04:17 2006, Doug Preddy, Normal Running, test M9daily log070306.XLS
Entry  Thu Jul 6 15:00:15 2006, Doug Preddy, Normal Running, test 
Entry  Mon Jul 3 23:01:34 2006, Doug Preddy, Quench Recovery, power lead warming/ripples caused quench 
Entry  Fri Jun 30 11:17:57 2006, Doug Preddy, Normal Running, Solenoid recovered 
Entry  Fri Jun 30 11:13:00 2006, Doug Preddy, Normal Running, E-log is back up and running 
Entry  Fri Jun 16 08:12:04 2006, Doug Preddy, Normal Running, LI108 indicates high on EPICS screen 
Entry  Wed Jun 14 16:27:01 2006, Willy Andersson, Quench Recovery, Energized solenoid 
Entry  Wed Jun 14 10:35:30 2006, Willy Andersson, Quench Recovery, Switched to series cooling. 
Entry  Tue Jun 13 16:04:33 2006, Willy Andersson, Quench Recovery, TIC 121 set to auto mode 
Entry  Tue Jun 13 15:52:46 2006, Willy Andersson, Quench Recovery, Doug has reduced and now closed CV155. 
Entry  Tue Jun 13 10:54:27 2006, Doug Preddy, Quench Recovery, Compressor tripped off 
Entry  Tue May 30 14:36:41 2006, Doug Preddy, Normal Running, power leads warming 
Entry  Fri May 26 14:34:24 2006, Doug Preddy, Start Up, Ready to run 
Entry  Fri May 26 10:03:03 2006, Doug Preddy, Start Up, Started flow to power leads 
Entry  Fri May 26 08:45:38 2006, Doug Preddy, Start Up, Changed to series mode 
Entry  Fri May 26 07:29:54 2006, Doug Preddy, Start Up, CV155 closed 
Entry  Thu May 25 07:34:18 2006, Doug Preddy, Start Up, switched to parallel cold return 
Entry  Tue May 23 08:44:28 2006, Doug Preddy, Start Up, Started turbines 
Entry  Thu Dec 22 15:10:44 2005, Doug Preddy, Shut Down, shut down system 
Entry  Mon Dec 12 09:24:29 2005, Doug Preddy, Quench Recovery, Solenoid Quench on power lead temp 
Entry  Tue Nov 15 07:25:10 2005, Doug Preddy, Normal Running, power supply problem 
Entry  Thu Nov 3 09:27:16 2005, Doug Preddy, Quench Recovery, started flow to solenoid 
Entry  Thu Nov 3 06:19:50 2005, Doug Preddy, Quench Recovery, restart system 
Entry  Wed Nov 2 10:17:27 2005, Willy Andersson, Start Up, M9B helium refrigerator and solenoid cooldown 
Entry  Mon Oct 31 07:48:57 2005, Willy Andersson, Quench Recovery, what a fine entry 
Entry  Sun Aug 14 10:03:13 2005, Willy Andersson, Normal Running, System stable 
Entry  Tue Jul 19 18:09:56 2005, Willy Andersson, Quench Recovery, Quench II 
Entry  Tue Jul 19 16:13:32 2005, Willy Andersson, Quench Recovery, switch to series mode 
Entry  Mon Jul 18 15:51:17 2005, Doug Preddy, Quench Recovery, Compressor restarted, flow to solenoid 
Entry  Mon Jul 18 11:18:40 2005, Doug Preddy, Quench Recovery, Solenoid Quenched over the weekend 
Entry  Tue Jun 14 23:01:22 2005, Doug Preddy, Quench Recovery, switched to parallel cold return 
Entry  Tue Jun 14 20:53:19 2005, Doug Preddy, Quench Recovery, restarted refrigerator after power bump june142045.BMP
Entry  Tue Jun 14 18:48:14 2005, Experimentor, Normal Running, Power bump at 18:40 
Entry  Thu Jun 9 21:41:25 2005, Willy Andersson, Quench Recovery, Trying to achieve stable cooling. 
Entry  Thu Jun 9 08:56:10 2005, Doug Preddy, Quench Recovery, system back on 
Entry  Thu Jun 9 06:53:40 2005, Experimentor, Other, Trip at 6:45 Today.  
Entry  Thu Jun 2 09:16:40 2005, Doug Preddy, Quench Recovery, continuing to cool 02-06-05-7.32.49 AM.jpg
Entry  Thu Jun 2 01:38:25 2005, Doug Preddy, Quench Recovery, strip tool plot 02-06-05-12.57.26 AM.jpg
Entry  Thu Jun 2 01:26:30 2005, Doug Preddy, Quench Recovery, started flow to solenoid Capture6-2-05-1.13.33 AM.jpg
Entry  Wed Jun 1 23:48:02 2005, Doug Preddy, Quench Recovery, the first quench 
Entry  Wed Jun 1 08:23:19 2005, Doug Preddy, Start Up, start up notes 
Entry  Thu May 19 15:05:31 2005, Doug Preddy, Maintenance, STA 120 replaced M9 Turbine 2.doc
Entry  Mon Apr 18 09:52:11 2005, Doug Preddy, Maintenance, Relays replaced 
Entry  Fri Mar 11 09:18:30 2005, Doug Preddy, Maintenance, services on system 
Entry  Sun Dec 5 11:15:24 2004, Doug Preddy, Normal Running, more ripples 
Entry  Thu Dec 2 10:51:16 2004, Doug Preddy, Normal Running, power lead ripple 
Entry  Wed Dec 1 12:55:56 2004, Doug Preddy, Normal Running, added one bottle helium gas 
Entry  Mon Nov 29 09:28:16 2004, Doug Preddy, Normal Running, Buffer tank empty 
Entry  Sun Nov 28 10:15:18 2004, Willy Andersson, Quench Recovery, Powerlead quench ? 
Entry  Thu Nov 25 07:21:37 2004, Doug Preddy, Quench Recovery, started power lead flow 
Entry  Wed Nov 24 14:58:42 2004, Doug Preddy, Quench Recovery, today 
Entry  Wed Nov 24 07:28:38 2004, Other, , Mission Impossible 
Entry  Wed Nov 24 07:28:30 2004, Other, , Mission Impossible 
Entry  Tue Nov 23 15:10:06 2004, Doug Preddy, Quench Recovery, switched to parallel cold return mode 
Entry  Tue Nov 23 11:35:44 2004, Doug Preddy, Quench Recovery, Another power bump 
Entry  Tue Nov 23 09:30:15 2004, Doug Preddy, Quench Recovery, started flow to solenoid 
Entry  Tue Nov 23 07:47:00 2004, Doug Preddy, Quench Recovery, Solenoid quench Nov 21 11_22_04_7_40.BMP
Entry  Thu Nov 4 13:33:49 2004, Doug Preddy, Normal Running, Power supply problems 
Entry  Mon Nov 1 07:17:44 2004, Doug Preddy, Normal Running, power lead flow gone bad 
Entry  Fri Oct 29 14:25:23 2004, Doug Preddy, Normal Running, power lead flows dropping 
Entry  Tue Oct 26 09:45:24 2004, Doug Preddy, Normal Running, power leads warming 
Entry  Mon Oct 25 15:44:15 2004, Doug Preddy, Normal Running, Power lead temps starting to ripple 
Entry  Fri Oct 22 09:15:06 2004, Doug Preddy, Start Up, started flow to power leads 
Entry  Thu Oct 21 15:41:29 2004, Doug Preddy, Start Up, switched to series mode 
Entry  Thu Oct 21 07:16:35 2004, Doug Preddy, Start Up, switched to parallel cold return 
Entry  Wed Oct 20 09:38:17 2004, Doug Preddy, Start Up, restarting system 
Entry  Sun Oct 17 05:03:13 2004, Other, Start Up, Cycle valve after oscillations begin 
Entry  Wed Oct 13 08:17:00 2004, Experimentor, Start Up, cycling 142 when temp hit 10.68 
    Reply  Sun Oct 17 04:26:29 2004, Other, Start Up, cycling 142 when temp hit 10.68 
Entry  Sat Oct 16 17:18:50 2004, Other, , lame 
Entry  Sat Oct 16 17:13:19 2004, Other, , s 
Entry  Tue Oct 12 13:00:08 2004, Curtis Ballard, Start Up, cv142 valve 
Entry  Tue Oct 12 02:05:31 2004, Experimentor, Start Up, cv142 valve 
Entry  Mon Oct 11 22:32:11 2004, Experimentor, Start Up, cv142 valve 
Entry  Mon Oct 11 11:49:34 2004, Experimentor, Start Up, cv142 valve 
Entry  Mon Oct 11 03:56:14 2004, Experimentor, Start Up, cv142 valve 
Entry  Sun Oct 10 17:36:35 2004, Experimentor, Start Up, power leads 
Entry  Sat Oct 9 22:50:26 2004, Other, , power leads warmed 
Entry  Thu Oct 7 13:33:20 2004, Doug Preddy, Start Up, turned off purifier 
Entry  Wed Oct 6 09:25:54 2004, Doug Preddy, Start Up, switch to series mode 
Entry  Wed Oct 6 07:57:01 2004, Doug Preddy, Start Up, parallel cold return 
Entry  Tue Oct 5 07:18:16 2004, Doug Preddy, Start Up, adjust compressor discharge pressure 
Entry  Mon Oct 4 09:16:29 2004, Doug Preddy, Start Up, Started turbines 
Entry  Fri Oct 1 11:39:55 2004, Doug Preddy, Maintenance, Loading of compressor not working 
Entry  Mon Sep 13 13:56:06 2004, Doug Preddy, Shut Down, compressor off 
Entry  Mon Sep 13 10:55:25 2004, Doug Preddy, Shut Down, Quench and shutdown 
Entry  Fri Sep 3 01:28:43 2004, Doug Preddy, Quench Recovery, power up 
Entry  Thu Sep 2 21:58:34 2004, Willy Andersson, Quench Recovery, Switch to series cooling 
Entry  Sun Aug 29 14:39:19 2004, Doug Preddy, Normal Running, Power lead ripple 
Entry  Wed Aug 25 12:52:53 2004, Doug Preddy, Normal Running, power lead ripple 
Entry  Wed Aug 25 07:47:05 2004, Doug Preddy, Normal Running, Power lead flow 
Entry  Tue Aug 24 12:09:50 2004, Doug Preddy, Normal Running, The past few days 
Entry  Thu Aug 19 10:28:32 2004, Doug Preddy, Start Up, after M9bv5 FIX 
Entry  Sat Aug 7 23:40:47 2004, Willy Andersson, Quench Recovery, Energizing solenoid 
Entry  Sat Aug 7 22:37:04 2004, Willy Andersson, Quench Recovery, Compressor tripped off. 
Entry  Thu Jul 29 13:25:29 2004, Doug Preddy, Quench Recovery, start flow to power leads 
Entry  Thu Jul 29 09:01:11 2004, Doug Preddy, Quench Recovery, switched to parallel cold 
Entry  Wed Jul 28 23:07:01 2004, Doug Preddy, Quench Recovery, solenoid cooling 
Entry  Wed Jul 28 22:01:31 2004, Doug Preddy, Quench Recovery, Starting flow to solenoid 
Entry  Wed Jul 28 21:26:19 2004, Doug Preddy, Quench Recovery, Double Power bump 
Entry  Wed Jul 28 07:00:18 2004, Doug Preddy, Quench Recovery, switch to series mode 
Entry  Wed Jul 28 00:04:30 2004, Doug Preddy, Quench Recovery, started flow to solenoid 
Entry  Tue Jul 27 23:33:27 2004, Doug Preddy, Quench Recovery, Solenoid quench 9:30 
Entry  Tue Jun 29 14:59:46 2004, Willy Andersson, Normal Running, Removed jumper on vacuum controller. 
Entry  Fri Jun 25 14:20:58 2004, Willy Andersson, Quench Recovery, Switch to series mode 
Entry  Fri Jun 25 12:36:04 2004, Willy Andersson, Quench Recovery, Compressor unloaded etc. 
Entry  Fri May 21 09:27:39 2004, Doug Preddy, Maintenance, Idle mode 
Entry  Thu May 6 09:32:13 2004, Willy Andersson, Quench Recovery, Additional notes from last night power lead problems. 
Entry  Wed May 5 23:57:38 2004, Willy Andersson, Quench Recovery, Powerleads warming up again. may5_04_1800.BMP
Entry  Wed May 5 12:13:51 2004, Doug Preddy, Normal Running, power leads cold 
Entry  Wed May 5 09:59:10 2004, Doug Preddy, Quench Recovery, started flow to power leads 
Entry  Wed May 5 07:55:37 2004, Doug Preddy, Quench Recovery, Solenoid quenched on power lead temp may5_745.BMP
Entry  Tue May 4 11:26:38 2004, Doug Preddy, Normal Running, power leads  may4_1053.BMP
Entry  Tue May 4 11:20:57 2004, Doug Preddy, Normal Running, power leads going unstable 
Entry  Fri Apr 30 01:53:34 2004, Doug Preddy, Quench Recovery, switched to parallel cold 
Entry  Thu Apr 29 23:43:15 2004, Doug Preddy, Quench Recovery, Starting flow to solenoid 
Entry  Wed Apr 28 09:30:09 2004, Doug Preddy, Normal Running, power leads again 
Entry  Tue Apr 27 09:03:18 2004, Doug Preddy, Normal Running, Power leads 
Entry  Mon Apr 26 08:12:30 2004, Doug Preddy, Quench Recovery, Power leads flow 
Entry  Mon Apr 26 07:48:46 2004, Doug Preddy, Quench Recovery, Series mode 
Entry  Sun Apr 25 21:41:00 2004, Willy Andersson, Quench Recovery, Trip on PL Temp. 
Entry  Fri Apr 23 09:19:30 2004, Doug Preddy, Normal Running, CV211 
Entry  Thu Apr 22 10:39:16 2004, Doug Preddy, Normal Running, Yesterday 
Entry  Wed Apr 21 09:57:59 2004, Willy Andersson, Start Up, System status 
Entry  Wed Apr 21 08:16:18 2004, Doug Preddy, Start Up, switch to series mode 
Entry  Wed Apr 21 06:48:31 2004, Doug Preddy, Start Up, JT bypass closed 
Entry  Wed Apr 21 06:39:17 2004, Doug Preddy, Start Up, over night 
Entry  Tue Apr 20 07:33:03 2004, Doug Preddy, Start Up, PIC229 at 11bar 
Entry  Tue Apr 20 07:06:41 2004, Doug Preddy, Start Up, morning day 2 april200705.BMP
Entry  Mon Apr 19 15:06:49 2004, Doug Preddy, Start Up, Started turbines april191500.BMP
Entry  Fri Apr 16 10:15:26 2004, Doug Preddy, Start Up, Changes to M9sol Vacuum PC 
Entry  Fri Dec 19 13:07:25 2003, Willy Andersson, Maintenance, To-Do list for M9SOL M9Blist3.txt
    Reply  Fri Dec 19 13:59:53 2003, Doug Preddy, Maintenance, To-Do list for M9SOL 
Entry  Fri Dec 19 11:34:10 2003, Doug Preddy, Quench Recovery, Final home of this E-log 
ELOG V2.9.2-2455