Solenoid had tripped on powerlead overtemp at about 09:00 this morning.
Doug recovered the system to // cooling. I switched system to series
cooling at about 21:30. LHe level at about 10%. Buffer tank pressure is low
at about 13 psig. Letting LHe level build. Once LHe level rises to about
35% then I suggest starting flow to the powerleads by opening HIC142 fully
open. LHe level should continue to build but at a much slower rate. Once
power lead temps have bottomed out to cr_pl_neg < 9K and cr_pl_pos < 11 K
(check these values with archived data first) and are stable then can
energize solenoid. |