When the compressor was restarted on Monday, the remote load button would
not respond. The compressor was shut off. After two days of searching the
wiring etc. a bad connection was found on DR1 relay (upstairs in the
compressor control panel). The wire was the "compressor on" sensor.
Connection was cleaned and retightened.
The compressor was started this morning and is working.
I pressurized the cold box and started flow to the solenoid and through the
power leads. I started a continuous flow throughthe LN2 adsorber. This will
be run over the weekend. Cooling to start Monday morning. |