The solenoid was pumped out Monday and yesterday after the quads just
downstream of the solenoid were put back in place. The quad just
downstream of the solenoid was remove to replace two coils on it.
The cold box vacuum had tripped off some time in the last little while.
Started it pumping on Monday also. The compressor was started Tuesday
afternoon and flow was started to the solenoid. The purifier was
regenerated and put on line in it's total buffer tank flow mode. The cold
box was pressurized and the turbines were briefly spun up to check the
operation of the new turbine speed indicator. It seems to be working
properly.
Flow to the turbines was started this morning and all went well. The speed
indicator works properly.
M9BIG1 started ot 6.6 x 10-6 before flow was started. One hour later it
reads 4.8 x 10-6 |