+
Fri Dec 19 13:07:25 2003, Willy Andersson, Maintenance, To-Do list for M9SOL
|
Wed Apr 21 09:57:59 2004, Willy Andersson, Start Up, System status
|
Sun Apr 25 21:41:00 2004, Willy Andersson, Quench Recovery, Trip on PL Temp.
|
Wed May 5 23:57:38 2004, Willy Andersson, Quench Recovery, Powerleads warming up again.
|
Thu May 6 09:32:13 2004, Willy Andersson, Quench Recovery, Additional notes from last night power lead problems.
|
Fri Jun 25 12:36:04 2004, Willy Andersson, Quench Recovery, Compressor unloaded etc.
|
Fri Jun 25 14:20:58 2004, Willy Andersson, Quench Recovery, Switch to series mode
|
Tue Jun 29 14:59:46 2004, Willy Andersson, Normal Running, Removed jumper on vacuum controller.
|
Sat Aug 7 22:37:04 2004, Willy Andersson, Quench Recovery, Compressor tripped off.
|
Sat Aug 7 23:40:47 2004, Willy Andersson, Quench Recovery, Energizing solenoid
|
Thu Sep 2 21:58:34 2004, Willy Andersson, Quench Recovery, Switch to series cooling
|
Sun Nov 28 10:15:18 2004, Willy Andersson, Quench Recovery, Powerlead quench ?
|
Thu Jun 9 21:41:25 2005, Willy Andersson, Quench Recovery, Trying to achieve stable cooling.
|
Tue Jul 19 16:13:32 2005, Willy Andersson, Quench Recovery, switch to series mode
|
Tue Jul 19 18:09:56 2005, Willy Andersson, Quench Recovery, Quench II
|
Sun Aug 14 10:03:13 2005, Willy Andersson, Normal Running, System stable
|
Mon Oct 31 07:48:57 2005, Willy Andersson, Quench Recovery, what a fine entry
|
Wed Nov 2 10:17:27 2005, Willy Andersson, Start Up, M9B helium refrigerator and solenoid cooldown
|
Tue Jun 13 15:52:46 2006, Willy Andersson, Quench Recovery, Doug has reduced and now closed CV155.
|
Tue Jun 13 16:04:33 2006, Willy Andersson, Quench Recovery, TIC 121 set to auto mode
|
Wed Jun 14 10:35:30 2006, Willy Andersson, Quench Recovery, Switched to series cooling.
|
Wed Jun 14 16:27:01 2006, Willy Andersson, Quench Recovery, Energized solenoid
|
Thu Jul 20 11:01:09 2006, Willy Andersson, Quench Recovery, Opened up warm return valves CV151 and CV153
|
Thu Jul 20 13:21:57 2006, Willy Andersson, Quench Recovery, started // warm return flow.
|
Thu Jul 20 13:27:21 2006, Willy Andersson, Quench Recovery, cold return mode continues...
|
Thu Jul 20 13:34:26 2006, Willy Andersson, Quench Recovery, cold return mode continues...
|
Fri Jul 21 17:18:19 2006, Willy Andersson, Quench Recovery, Opened HIC142 fully open
|
Wed Aug 9 06:44:58 2006, Willy Andersson, Quench Recovery, // cold mode cooling continues.
|
Wed Aug 9 06:59:43 2006, Willy Andersson, Quench Recovery, more // cold return stuff
|
Thu Aug 10 16:33:11 2006, Willy Andersson, Quench Recovery, Flow to solenoid tripped on powerlead temperature.
|
Thu Aug 10 20:26:09 2006, Willy Andersson, Quench Recovery, solenoid energized
|
Tue Aug 15 15:39:27 2006, Willy Andersson, Quench Recovery, switched to parallel cold return
|
Thu Aug 17 19:45:27 2006, Willy Andersson, Quench Recovery, switch to series cooling
|
Wed Oct 4 18:10:18 2006, Willy Andersson, Start Up, Quick check on system
|
Thu Oct 12 11:53:04 2006, Willy Andersson, Quench Recovery, Compressor trip, 09:50 this morning.
| +
Thu Oct 12 19:54:10 2006, Willy Andersson, Quench Recovery, Energized solenoid.
|
Thu Oct 26 04:27:31 2006, Willy Andersson, Quench Recovery, Powerlead overtemp
|
Thu Oct 26 04:34:15 2006, Willy Andersson, Quench Recovery, Still in // cold return mode.
|
Wed Nov 15 17:05:49 2006, Willy Andersson, Quench Recovery, powerleads cold, energizing solenoid
|
Sat Oct 9 22:50:26 2004, Other, , power leads warmed
|
Sat Oct 16 17:13:19 2004, Other, , s
|
Sat Oct 16 17:18:50 2004, Other, , lame
| +
Sun Oct 17 04:26:29 2004, Other, Start Up, cycling 142 when temp hit 10.68
|
Sun Oct 17 05:03:13 2004, Other, Start Up, Cycle valve after oscillations begin
|
Wed Nov 24 07:28:30 2004, Other, , Mission Impossible
|
Wed Nov 24 07:28:38 2004, Other, , Mission Impossible
|
Sun Oct 15 07:09:41 2006, Other, Normal Running, cryopump bcp2 trip
|
Fri Apr 27 10:16:44 2007, Kevin Trithardt, Quench Recovery, Test
|
Thu Jul 5 11:01:47 2007, Kevin Trithardt, Other, Current lead warm up
|
Tue Jul 31 07:53:57 2007, Kevin Trithardt, Normal Running, cycled power leads
|
Wed Nov 28 15:07:08 2007, Kevin Trithardt, Other, power lead regeneration
|
Mon Mar 29 09:25:52 2010, Kevin Trithardt, Start Up, Started cool down this morning
|
Tue May 18 15:04:36 2010, Kevin Trithardt, Maintenance, Solenoid ramping up
|
Sun Oct 10 17:36:35 2004, Experimentor, Start Up, power leads
|
Mon Oct 11 03:56:14 2004, Experimentor, Start Up, cv142 valve
|
Mon Oct 11 11:49:34 2004, Experimentor, Start Up, cv142 valve
|
Mon Oct 11 22:32:11 2004, Experimentor, Start Up, cv142 valve
|
Tue Oct 12 02:05:31 2004, Experimentor, Start Up, cv142 valve
| +
Wed Oct 13 08:17:00 2004, Experimentor, Start Up, cycling 142 when temp hit 10.68
|
Thu Jun 9 06:53:40 2005, Experimentor, Other, Trip at 6:45 Today.
|
Tue Jun 14 18:48:14 2005, Experimentor, Normal Running, Power bump at 18:40
|
Sat Jul 22 06:34:14 2006, Experimentor, Quench Recovery, looking good
| +
Fri Oct 13 00:13:57 2006, Experimentor, Quench Recovery, Energized solenoid.
|
Fri Dec 19 11:34:10 2003, Doug Preddy, Quench Recovery, Final home of this E-log
| +
Fri Dec 19 13:59:53 2003, Doug Preddy, Maintenance, To-Do list for M9SOL
|
Fri Apr 16 10:15:26 2004, Doug Preddy, Start Up, Changes to M9sol Vacuum PC
|
Mon Apr 19 15:06:49 2004, Doug Preddy, Start Up, Started turbines
|
Tue Apr 20 07:06:41 2004, Doug Preddy, Start Up, morning day 2
|
Tue Apr 20 07:33:03 2004, Doug Preddy, Start Up, PIC229 at 11bar
|
Wed Apr 21 06:39:17 2004, Doug Preddy, Start Up, over night
|
Wed Apr 21 06:48:31 2004, Doug Preddy, Start Up, JT bypass closed
|
Wed Apr 21 08:16:18 2004, Doug Preddy, Start Up, switch to series mode
|
Thu Apr 22 10:39:16 2004, Doug Preddy, Normal Running, Yesterday
|
Fri Apr 23 09:19:30 2004, Doug Preddy, Normal Running, CV211
|
Mon Apr 26 07:48:46 2004, Doug Preddy, Quench Recovery, Series mode
|
Mon Apr 26 08:12:30 2004, Doug Preddy, Quench Recovery, Power leads flow
|
Tue Apr 27 09:03:18 2004, Doug Preddy, Normal Running, Power leads
|
Wed Apr 28 09:30:09 2004, Doug Preddy, Normal Running, power leads again
|
Thu Apr 29 23:43:15 2004, Doug Preddy, Quench Recovery, Starting flow to solenoid
|
Fri Apr 30 01:53:34 2004, Doug Preddy, Quench Recovery, switched to parallel cold
|
Tue May 4 11:20:57 2004, Doug Preddy, Normal Running, power leads going unstable
|
Tue May 4 11:26:38 2004, Doug Preddy, Normal Running, power leads
|
Wed May 5 07:55:37 2004, Doug Preddy, Quench Recovery, Solenoid quenched on power lead temp
|
Wed May 5 09:59:10 2004, Doug Preddy, Quench Recovery, started flow to power leads
|
Wed May 5 12:13:51 2004, Doug Preddy, Normal Running, power leads cold
|
Fri May 21 09:27:39 2004, Doug Preddy, Maintenance, Idle mode
|
Tue Jul 27 23:33:27 2004, Doug Preddy, Quench Recovery, Solenoid quench 9:30
|
Wed Jul 28 00:04:30 2004, Doug Preddy, Quench Recovery, started flow to solenoid
|
Wed Jul 28 07:00:18 2004, Doug Preddy, Quench Recovery, switch to series mode
|
Wed Jul 28 21:26:19 2004, Doug Preddy, Quench Recovery, Double Power bump
|
Wed Jul 28 22:01:31 2004, Doug Preddy, Quench Recovery, Starting flow to solenoid
|
Wed Jul 28 23:07:01 2004, Doug Preddy, Quench Recovery, solenoid cooling
|
Thu Jul 29 09:01:11 2004, Doug Preddy, Quench Recovery, switched to parallel cold
|
Thu Jul 29 13:25:29 2004, Doug Preddy, Quench Recovery, start flow to power leads
|
Thu Aug 19 10:28:32 2004, Doug Preddy, Start Up, after M9bv5 FIX
|
Tue Aug 24 12:09:50 2004, Doug Preddy, Normal Running, The past few days
|
Wed Aug 25 07:47:05 2004, Doug Preddy, Normal Running, Power lead flow
|
Wed Aug 25 12:52:53 2004, Doug Preddy, Normal Running, power lead ripple
|
Sun Aug 29 14:39:19 2004, Doug Preddy, Normal Running, Power lead ripple
|
Fri Sep 3 01:28:43 2004, Doug Preddy, Quench Recovery, power up
|
Mon Sep 13 10:55:25 2004, Doug Preddy, Shut Down, Quench and shutdown
|
Mon Sep 13 13:56:06 2004, Doug Preddy, Shut Down, compressor off
|
Fri Oct 1 11:39:55 2004, Doug Preddy, Maintenance, Loading of compressor not working
|
Mon Oct 4 09:16:29 2004, Doug Preddy, Start Up, Started turbines
|
Tue Oct 5 07:18:16 2004, Doug Preddy, Start Up, adjust compressor discharge pressure
|
Wed Oct 6 07:57:01 2004, Doug Preddy, Start Up, parallel cold return
|
Wed Oct 6 09:25:54 2004, Doug Preddy, Start Up, switch to series mode
|
Thu Oct 7 13:33:20 2004, Doug Preddy, Start Up, turned off purifier
|
Wed Oct 20 09:38:17 2004, Doug Preddy, Start Up, restarting system
|
Thu Oct 21 07:16:35 2004, Doug Preddy, Start Up, switched to parallel cold return
|
Thu Oct 21 15:41:29 2004, Doug Preddy, Start Up, switched to series mode
|
Fri Oct 22 09:15:06 2004, Doug Preddy, Start Up, started flow to power leads
|
Mon Oct 25 15:44:15 2004, Doug Preddy, Normal Running, Power lead temps starting to ripple
|
Tue Oct 26 09:45:24 2004, Doug Preddy, Normal Running, power leads warming
|
Fri Oct 29 14:25:23 2004, Doug Preddy, Normal Running, power lead flows dropping
|
Mon Nov 1 07:17:44 2004, Doug Preddy, Normal Running, power lead flow gone bad
|
Thu Nov 4 13:33:49 2004, Doug Preddy, Normal Running, Power supply problems
|
Tue Nov 23 07:47:00 2004, Doug Preddy, Quench Recovery, Solenoid quench Nov 21
|
Tue Nov 23 09:30:15 2004, Doug Preddy, Quench Recovery, started flow to solenoid
|
Tue Nov 23 11:35:44 2004, Doug Preddy, Quench Recovery, Another power bump
|
Tue Nov 23 15:10:06 2004, Doug Preddy, Quench Recovery, switched to parallel cold return mode
|
Wed Nov 24 14:58:42 2004, Doug Preddy, Quench Recovery, today
|
Thu Nov 25 07:21:37 2004, Doug Preddy, Quench Recovery, started power lead flow
|
Mon Nov 29 09:28:16 2004, Doug Preddy, Normal Running, Buffer tank empty
|
Wed Dec 1 12:55:56 2004, Doug Preddy, Normal Running, added one bottle helium gas
|
Thu Dec 2 10:51:16 2004, Doug Preddy, Normal Running, power lead ripple
|
Sun Dec 5 11:15:24 2004, Doug Preddy, Normal Running, more ripples
|
Fri Mar 11 09:18:30 2005, Doug Preddy, Maintenance, services on system
|
Mon Apr 18 09:52:11 2005, Doug Preddy, Maintenance, Relays replaced
|
Thu May 19 15:05:31 2005, Doug Preddy, Maintenance, STA 120 replaced
|
Wed Jun 1 08:23:19 2005, Doug Preddy, Start Up, start up notes
|
Wed Jun 1 23:48:02 2005, Doug Preddy, Quench Recovery, the first quench
|
Thu Jun 2 01:26:30 2005, Doug Preddy, Quench Recovery, started flow to solenoid
|
Thu Jun 2 01:38:25 2005, Doug Preddy, Quench Recovery, strip tool plot
|
Thu Jun 2 09:16:40 2005, Doug Preddy, Quench Recovery, continuing to cool
|
Thu Jun 9 08:56:10 2005, Doug Preddy, Quench Recovery, system back on
|
Tue Jun 14 20:53:19 2005, Doug Preddy, Quench Recovery, restarted refrigerator after power bump
|
Tue Jun 14 23:01:22 2005, Doug Preddy, Quench Recovery, switched to parallel cold return
|
Mon Jul 18 11:18:40 2005, Doug Preddy, Quench Recovery, Solenoid Quenched over the weekend
|
Mon Jul 18 15:51:17 2005, Doug Preddy, Quench Recovery, Compressor restarted, flow to solenoid
|
Thu Nov 3 06:19:50 2005, Doug Preddy, Quench Recovery, restart system
|
Thu Nov 3 09:27:16 2005, Doug Preddy, Quench Recovery, started flow to solenoid
|
Tue Nov 15 07:25:10 2005, Doug Preddy, Normal Running, power supply problem
|
Mon Dec 12 09:24:29 2005, Doug Preddy, Quench Recovery, Solenoid Quench on power lead temp
|
Thu Dec 22 15:10:44 2005, Doug Preddy, Shut Down, shut down system
|
Tue May 23 08:44:28 2006, Doug Preddy, Start Up, Started turbines
|
Thu May 25 07:34:18 2006, Doug Preddy, Start Up, switched to parallel cold return
|
Fri May 26 07:29:54 2006, Doug Preddy, Start Up, CV155 closed
|
Fri May 26 08:45:38 2006, Doug Preddy, Start Up, Changed to series mode
|
Fri May 26 10:03:03 2006, Doug Preddy, Start Up, Started flow to power leads
|
Fri May 26 14:34:24 2006, Doug Preddy, Start Up, Ready to run
|
Tue May 30 14:36:41 2006, Doug Preddy, Normal Running, power leads warming
|
Tue Jun 13 10:54:27 2006, Doug Preddy, Quench Recovery, Compressor tripped off
|
Fri Jun 16 08:12:04 2006, Doug Preddy, Normal Running, LI108 indicates high on EPICS screen
|
Fri Jun 30 11:13:00 2006, Doug Preddy, Normal Running, E-log is back up and running
|
Fri Jun 30 11:17:57 2006, Doug Preddy, Normal Running, Solenoid recovered
|
Mon Jul 3 23:01:34 2006, Doug Preddy, Quench Recovery, power lead warming/ripples caused quench
|
Thu Jul 6 15:00:15 2006, Doug Preddy, Normal Running, test
|
Thu Jul 6 15:04:17 2006, Doug Preddy, Normal Running, test
|
Thu Jul 20 00:25:16 2006, Doug Preddy, Quench Recovery, Solenoid quenched @ 11:15
|
Thu Jul 20 00:52:13 2006, Doug Preddy, Quench Recovery, T1 frozen
|
Thu Jul 20 02:59:06 2006, Doug Preddy, Quench Recovery, T1 still not starting
|
Thu Jul 20 08:18:31 2006, Doug Preddy, Quench Recovery, T1 started
|
Fri Jul 21 07:39:37 2006, Doug Preddy, Quench Recovery, Cool down continues
|
Fri Jul 21 14:08:04 2006, Doug Preddy, Quench Recovery, switch to series mode
|
Fri Jul 21 23:36:21 2006, Doug Preddy, Quench Recovery, Final cooldown problems
|
Fri Jul 28 20:39:40 2006, Doug Preddy, Quench Recovery, Restarting refrigerator
|
Sat Jul 29 05:30:28 2006, Doug Preddy, Quench Recovery, switched to series mode
|
Sat Jul 29 09:38:06 2006, Doug Preddy, Quench Recovery, power leads cooled
|
Tue Aug 8 07:27:49 2006, Doug Preddy, Quench Recovery, Solenoid Quench at about 6:00 this morning
|
Wed Aug 9 07:50:49 2006, Doug Preddy, Quench Recovery, Switched to series mode.
|
Thu Aug 10 08:33:44 2006, Doug Preddy, Normal Running, Running low on helium
|
Tue Aug 15 08:45:56 2006, Doug Preddy, Quench Recovery, restarted the compressor
|
Thu Aug 17 08:04:44 2006, Doug Preddy, Quench Recovery, Solenoid tripped at about 3:00 this morning
|
Wed Oct 4 07:29:04 2006, Doug Preddy, Start Up, Starting cool down
|
Thu Oct 5 10:26:26 2006, Doug Preddy, Start Up, switched to parallel cold return
|
Thu Oct 5 11:51:53 2006, Doug Preddy, Start Up, Adde 2 bottles UHP Helium
|
Thu Oct 5 14:53:54 2006, Doug Preddy, Start Up, Switched to series mode
|
Thu Oct 26 08:18:10 2006, Doug Preddy, Quench Recovery, switched to series mode
|
Thu Oct 26 11:45:22 2006, Doug Preddy, Quench Recovery, Solenoid cold
|
Thu Oct 26 14:14:57 2006, Doug Preddy, Quench Recovery, power lead quench
|
Tue Oct 31 03:52:29 2006, Doug Preddy, Quench Recovery, power lead quench at 2:30 this morning
|
Tue Oct 31 05:36:14 2006, Doug Preddy, Quench Recovery, switch to series mode
|
Tue Oct 31 08:37:34 2006, Doug Preddy, Quench Recovery, Energizing solenoid
|
Fri Nov 3 12:09:51 2006, Doug Preddy, Normal Running, Fine tuning
|
Tue Nov 7 10:35:32 2006, Doug Preddy, Normal Running, Maintenance day
|
Wed Nov 15 11:09:28 2006, Doug Preddy, Quench Recovery, Compressor tripped off
|
Wed Nov 15 13:56:00 2006, Doug Preddy, Quench Recovery, switch to series mode
|
Tue Nov 28 10:32:04 2006, Doug Preddy, Quench Recovery, recovering after looong power outage
|
Fri Jan 26 15:10:37 2007, Doug Preddy, Maintenance, new control computer installed
|
Mon Mar 5 14:59:41 2007, Doug Preddy, Maintenance, Password
|
Thu Apr 19 15:18:25 2007, Doug Preddy, Start Up, preparing to start the refrigerator
|
Fri Apr 20 12:15:12 2007, Doug Preddy, Start Up, remote PLC switch
|
Mon Apr 23 16:31:02 2007, Doug Preddy, Start Up, Started compressor
|
Tue Apr 24 10:21:49 2007, Doug Preddy, Start Up, Started flow to turbines
|
Fri Apr 27 10:10:07 2007, Doug Preddy, Normal Running, Solenoid Cold
|
Fri Apr 27 10:32:07 2007, Doug Preddy, Quench Recovery, Reset quench relay logic box
|
Mon Apr 30 09:30:26 2007, Doug Preddy, Normal Running, problems over weekend
|
Wed May 2 16:28:16 2007, Doug Preddy, Normal Running, Energizing solenoid to 500 amps
|
Wed May 16 10:02:35 2007, Doug Preddy, Maintenance, warming up power leads
|
Wed May 30 08:38:38 2007, Doug Preddy, Quench Recovery, Solenoid quenched this morning
|
Wed May 30 11:27:32 2007, Doug Preddy, Quench Recovery, Problems recovering
|
Thu May 31 07:11:05 2007, Doug Preddy, Quench Recovery, switched to parallel cold return
|
Thu May 31 11:51:49 2007, Doug Preddy, Quench Recovery, Switched to series mode
|
Tue Jun 12 12:48:25 2007, Doug Preddy, Maintenance, added one bottle UHP helium to system
|
Thu Jun 14 00:10:10 2007, Doug Preddy, Quench Recovery, recovering from earlier quench
|
Sat Jun 16 15:05:03 2007, Doug Preddy, Normal Running, Solenoid power lead temp problem
|
Tue Jun 19 21:15:41 2007, Doug Preddy, Quench Recovery, Today's quench
|
Sun Jul 1 16:09:37 2007, Doug Preddy, Normal Running, M9B:DP2 tripped off
|
Wed Jul 4 11:13:12 2007, Doug Preddy, Quench Recovery, test
|
Thu Jul 5 03:04:50 2007, Doug Preddy, Normal Running, Power lead problems
|
Sat Jul 28 15:45:17 2007, Doug Preddy, Quench Recovery, quench recovery
|
Sat Jul 28 22:30:13 2007, Doug Preddy, Quench Recovery, quench again
|
Sun Jul 29 04:58:27 2007, Doug Preddy, Quench Recovery, Energizing solenoid
|
Mon Aug 6 08:41:31 2007, Doug Preddy, Quench Recovery, Cold box trip at 6:00
|
Tue Aug 14 10:15:22 2007, Doug Preddy, Maintenance, Solenoid ramped down
|
Tue Aug 14 12:55:12 2007, Doug Preddy, Normal Running, Strip tool saves
|
Wed Sep 12 12:01:02 2007, Doug Preddy, Maintenance, regenerated adsorber
|
Fri Sep 14 12:44:52 2007, Doug Preddy, Start Up, started compressor
|
Wed Sep 19 20:53:18 2007, Doug Preddy, Maintenance, More diff pump news
|
Mon Sep 24 15:08:41 2007, Doug Preddy, Start Up, Started cool down this morning
|
Tue Sep 25 07:34:04 2007, Doug Preddy, Start Up, PIC229 to 11 bar
|
Wed Sep 26 08:52:46 2007, Doug Preddy, Start Up, switched to parallel cold return
|
Thu Sep 27 07:41:15 2007, Doug Preddy, Start Up, Solenoid cold
|
Tue Oct 2 13:02:37 2007, Doug Preddy, Normal Running, PLC problems
|
Fri Oct 5 10:25:43 2007, Doug Preddy, Quench Recovery, Unknown quench 2
|
Fri Oct 5 13:25:41 2007, Doug Preddy, Quench Recovery, funny graph
|
Tue Oct 9 12:58:22 2007, Doug Preddy, Quench Recovery, Solenoid Quench 2
|
Tue Oct 9 13:16:44 2007, Doug Preddy, Quench Recovery, switched to series mode
|
Wed Oct 24 12:04:06 2007, Doug Preddy, Maintenance, power lead and cryopump regeneration
|
Thu Nov 8 09:28:53 2007, Doug Preddy, Quench Recovery, started compressor
|
Fri Nov 9 07:37:44 2007, Doug Preddy, Quench Recovery, switched to series mode
|
Fri Nov 9 14:50:03 2007, Doug Preddy, Quench Recovery, Solenoid cold
|
Fri Nov 9 16:24:33 2007, Doug Preddy, Maintenance, 2APLC Died
|
Fri Nov 9 18:56:20 2007, Doug Preddy, Maintenance, System Ready to Run
|
Mon Nov 19 02:58:44 2007, Doug Preddy, Quench Recovery, Solenoid quenched on power lead over temperature
|
Mon Nov 19 04:30:47 2007, Doug Preddy, Quench Recovery, switched to series mode
|
Fri Nov 23 08:35:37 2007, Doug Preddy, Normal Running, power lead problems
|
Fri Nov 23 08:41:45 2007, Doug Preddy, Normal Running, screen grab of powerlead temps
|
Mon Nov 26 09:45:43 2007, Doug Preddy, Normal Running, power lead problems
|
Tue Nov 27 21:02:08 2007, Doug Preddy, Normal Running, power lead ripples
|
Mon Dec 3 14:59:58 2007, Doug Preddy, Quench Recovery, Not really a quench recovery, But...
|
Tue Apr 1 15:17:06 2008, Doug Preddy, Start Up, Starting up vacuum systems
|
Wed Apr 16 15:12:01 2008, Doug Preddy, Normal Running, graphs to load
|
Wed Apr 16 15:15:44 2008, Doug Preddy, Start Up, refrigerator started
|
Wed Apr 16 16:51:16 2008, Doug Preddy, Start Up, switched to parallel cold return
|
Thu Apr 17 13:52:25 2008, Doug Preddy, Start Up, switched to series mode at 9:30 this morning
|
Mon Apr 28 09:03:22 2008, Doug Preddy, Normal Running, power leads warmed during weekend
|
Sun Jul 13 20:17:24 2008, Doug Preddy, Other, Helium refrigerator problems
|
Tue Jul 15 08:47:13 2008, Doug Preddy, Normal Running, Screen grab of normal running 
|
Thu Jul 24 16:28:50 2008, Doug Preddy, Quench Recovery, power bump
|
Fri Jul 25 21:48:15 2008, Doug Preddy, Quench Recovery, another quench
|
Sat Jul 26 01:06:04 2008, Doug Preddy, Quench Recovery, Refrigerator in series mode
|
Sat Jul 26 01:29:21 2008, Doug Preddy, Quench Recovery, power leads
|
Sat Aug 23 17:02:38 2008, Doug Preddy, Quench Recovery, Solenoid quenched
|
Sun Aug 24 06:45:14 2008, Doug Preddy, Quench Recovery, switch to series mode
|
Thu Sep 4 10:02:55 2008, Doug Preddy, Normal Running, ramping down solenoid
|
Tue Sep 9 15:04:23 2008, Doug Preddy, Maintenance, Jumpered interlock for diff pump water flow
|
Fri Sep 26 09:44:25 2008, Doug Preddy, Maintenance, Water flow interlock restored
|
Fri Sep 26 09:45:18 2008, Doug Preddy, Quench Recovery, Solenoid quenched at 7:50
|
Fri Sep 26 09:50:18 2008, Doug Preddy, Quench Recovery, started flow in parallel cold return mode
|
Sun Oct 5 11:12:48 2008, Doug Preddy, Normal Running, M9B:V1 interlocks and a IOC crash
|
Sun Oct 5 18:54:27 2008, Doug Preddy, Quench Recovery, Solenoid Quench ~16:30
|
Wed Nov 5 16:33:52 2008, Doug Preddy, Normal Running, sbplc light out
|
Wed Dec 10 15:41:04 2008, Doug Preddy, Shut Down, shuttting down solenoid
|
Wed Dec 10 15:44:58 2008, Doug Preddy, Maintenance, Repairs to solenoid power supply
|
Wed May 27 08:06:00 2009, Doug Preddy, Quench Recovery, Solenoid quenched at 5:00
|
Wed May 27 13:37:22 2009, Doug Preddy, Quench Recovery, switch to series mode
|
Wed May 27 15:01:34 2009, Doug Preddy, Quench Recovery, power leads
|
Fri Jul 10 00:34:03 2009, Doug Preddy, Quench Recovery, solewnoid quench due to power bump
|
Fri Jul 10 01:10:59 2009, Doug Preddy, Quench Recovery, switch to parallel warm return
|
Tue Jul 14 15:28:36 2009, Doug Preddy, Quench Recovery, Solenoid ramped up
|
Mon Oct 5 11:54:58 2009, Doug Preddy, Normal Running, Switched TIC121 into auto mode
|
Wed Mar 24 08:30:33 2010, Doug Preddy, Start Up, Start up
|
Thu Apr 1 11:57:55 2010, Doug Preddy, Start Up, started flow to power leads
|
Fri Apr 9 07:34:55 2010, Doug Preddy, Quench Recovery, switched to parallel cold return
|
Fri Apr 9 16:07:28 2010, Doug Preddy, Start Up, flow to power leads started
|
Mon May 3 07:49:54 2010, Doug Preddy, Quench Recovery, Solenoid quench Saturday
|
Thu May 13 07:39:55 2010, Doug Preddy, Quench Recovery, solenoid quench last night
|
Thu May 13 14:37:13 2010, Doug Preddy, Quench Recovery, switching to series mode.
|
Mon Jun 7 09:24:47 2010, Doug Preddy, Quench Recovery, started flow to power leads
|
Mon Aug 9 14:27:12 2010, Doug Preddy, Shut Down, Helium plant shut down
|
Thu Nov 11 15:46:40 2010, Doug Preddy, Other, switched to parallel cold return
|
Fri Nov 12 16:54:50 2010, Doug Preddy, Normal Running, Solenoid ramped up
|
Tue Oct 12 13:00:08 2004, Curtis Ballard, Start Up, cv142 valve
|
Tue Sep 18 18:48:11 2007, Curtis Ballard, Maintenance, cold box leak check
|
|