  152   Friday, May 30, 2025, 14:23 Darwin Ortiz RosalesC#5LP-SIS  45220-6 ReadyC#5 conditioningFriday, May 30, 2025, 14:21  C#5_Description.png 
  151   Monday, May 26, 2025, 09:54 Darwin Ortiz RosalesUCx#49LP-SIS  45447-1942972-2ReadyUCx#49_Description   UCx#49_Description.png 
  150   Wednesday, April 23, 2025, 10:35 Darwin Ortiz RosalesUCx#48LP-IG-LIS  45447-8 ReadyUCx#48_Description   UCx#48_Description.png 
  149   Thursday, January 02, 2025, 12:54 Darwin Ortiz RosalesUCx#47LP-SIS  45447-12 ReadyUCx#47_Description   UCx#47_Description.png 
  148   Tuesday, November 12, 2024, 12:49 Darwin Ortiz RosalesUCx#46LP-IG-LIS  42218-2 ReadyUCx#46_Description   UCx#46_Description.png 
  147   Monday, October 07, 2024, 13:16 Aaron SchmidtTa#68HP-SISITETM245447-2645235-16ReadyTa#68 Target Description Ta#68 HP-SIS  ITE-TM2-Ta#68-HP-SIS_Target_Loading_Data.pdf 
  146   Friday, September 20, 2024, 14:26 Aaron SchmidtTa#LP-SISITETM245447-1845235-13ReadyTa# Target DescriptionSpare for Ta#68 Ta#   
  145   Tuesday, September 10, 2024, 09:53 Darwin Ortiz RosalesTiC#9HP-SIS  45447-2945235-19ReadyTiC#9_Description   TiC#9.png 
  144   Tuesday, September 03, 2024, 16:11 Darwin Ortiz RosalesTiC#8HP-FEBIAD  45447-2 ReadyTiC#8_DescriptionThis was back-up target  TiC#8_(2).png 
  143   Tuesday, August 13, 2024, 10:08 Aaron SchmidtTa#67 Thin Foil TargetLP-SISITETM245447-1445235-10ReadyTa#67 Thin Foil Target description & Notes  T  Certificate_of_Analysis_-_Ta_0.01mm.pdf 
  142   Friday, June 14, 2024, 14:16 Darwin Ortiz RosalesTiC#7HP-FEBIAD  45447-545235-15ReadyTiC#7_DescriptionPlease note that this target comes in a
Graphite cartridge.
 TiC#7.png 
  141   Friday, June 14, 2024, 14:12 Darwin Ortiz RosalesSiC#46HP-SIS  44692-245235-6ReadySiC#46_description   SiC#46.png 
  140   Wednesday, May 22, 2024, 22:32 Darwin Ortiz RosalesUCx#45LP-SIS  45220-9 ReadyUCx#45_Description   UCx#45_Description.png 
  139   Tuesday, March 05, 2024, 10:15 Aaron SchmidtTaLP-SIS  45447-15 ReadyTa# (March stock) Target Description.Tuesday, March 05, 2024, 10:12: Ta#   
  138   Tuesday, October 24, 2023, 11:30 Darwin Ortiz RosalesUCx#44LP-FEBIAD  41790-7 ReadyUCx#44_DescriptionThree Ta heatshields left installed on
container.
 UCx#44_Description.png 
  137   Thursday, October 05, 2023, 12:48 Aaron Schmidt LP-SIS  45220-3  Ta#( ) Target description. (Spare)Ta# LP-SIS target  Ta#68_Target_Loading_Data.pdf 
  136   Wednesday, September 20, 2023, 14:25 Aaron SchmidtTa#66LP-SISITWTM245220-5 In progressTa#66 Target description.Ta#66 LP-SIS target description: 
 Ta#66_Target_Loading_Data.pdf 
  135   Thursday, August 24, 2023, 14:16 Aaron SchmidtNb#11LP-IG-LISITWTM245447-9 In progressNb#11 Target descriptionNb#11 LP-IG-LIS target description:
 Nb#11_Target_Loading_Data.pdf 
  134   Wednesday, July 26, 2023, 12:03 Darwin Ortiz RosalesUCx#43LP-SIS  45447-11 ReadyUCx#43_Description   UCx#43_Description.png 
  133   Wednesday, July 26, 2023, 09:42 Darwin Ortiz RosalesUCx#42LP-SIS  45220-1 ReadyUCx#42_Description   UCx#42_Description.png 
  132   Friday, June 23, 2023, 09:02 Aaron SchmidtNb#10LP-IG-LISITWTM245447-7  Nb#10 target description. Nb#10 LP-IG-LIS target
description:
  
  131   Friday, May 26, 2023, 11:53 Darwin Ortiz RosalesSiC#45HP-SIS  44692-3 Ready    SiC#45.png 
  130   Friday, May 26, 2023, 11:35 Darwin Ortiz RosalesTiC#6HP-SIS  44692-10 ReadyTarget TiC #6 Description   TiC_#6.png 
  129   Monday, May 01, 2023, 14:59 Darwin Ortiz RosalesTiC #5LP-FEBIAD  44692-5 ReadyTarget TiC #5 Description   TiC#5.png 
  128   Friday, March 10, 2023, 07:21 Aaron Schmidt      ReadyTarget Material Batch - Ta Tantalum - Standard foils.
MTR PO: TR-2022-03028
Average foil thickness: 0.0013"
 Ta_2023_-_01.pdf 
  127   Monday, March 06, 2023, 13:38 Aaron SchmidtTa#65LP-SIS  45220-7 ReadyTa#65 Target Description. Monday, March 06, 2023, 13:38:
Ta#65 LP-SIS target description: 
  
  126   Monday, February 06, 2023, 10:02 Darwin Ortiz RosalesTarget Reassigned (VOID ENTRY)   45220-6 ReadyTarget C#6 Description   C#6_Description.png 
  125   Wednesday, December 14, 2022, 10:28 Darwin Ortiz RosalesTarget reassigned (VOID ENTRY)   44691-13 ReadyTarget C#5 DescriptionGraphite target  C#5_Description.png 
  124   Tuesday, November 15, 2022, 08:41 Darwin Ortiz RosalesUCx#41LP-SIS  45220-13 Ready    UCx#41_Description.png 
  123   Tuesday, October 25, 2022, 13:10 Darwin Ortiz RosalesUCx#40LP-SIS  45550-2 ReadyUCx#40 Target DescriptionTuesday, October 25, 2022, 13:10 
Target in Glovebox
 UCx#40_Description.png 
  122   Thursday, September 22, 2022, 13:18 Darwin Ortiz RosalesC#4LP-SIS  44691-3 ReadyTarget C#4 DescriptionThursday, September 22, 2022, 13:17  C#4_Target_Description.png 
  121   Tuesday, August 16, 2022, 09:48 Darwin Ortiz RosalesSiC#44HP-FEBIAD  37978-1 ReadyTarget SiC#44 DescriptionTuesday, August 16, 2022, 09:47 
  
  120   Tuesday, August 09, 2022, 11:02 Darwin Ortiz RosalesUCx#39LP-IG-LIS  42218-4 ReadyUCx#39_Target_Description   UCx#39_Description.png 
  119   Friday, July 15, 2022, 10:47 Darwin Ortiz RosalesUCx#38LP-SIS  44508-3 ReadyUCx#38_Target_Description The bulk density was corrected.  Use
attachment number 2.
 
 UCx#38.pngUCx#38.png 
  118   Tuesday, June 21, 2022, 15:34 Matthew GareauSiC#42, SiC#43  TM2  Problems/SolutionsMultipin guide pin issues While removing the SiC#42 it became
apparent that the multipin guide pin had
become loose again and was not allowing the
  
  117   Monday, June 20, 2022, 10:35 Darwin Ortiz RosalesSiC#43HP-FEBIAD  42464-1 ReadyTarget SiC#43 DescriptionMonday, June 20, 2022, 10:33 
  
  116   Thursday, June 02, 2022, 16:55 Aaron SchmidtTa#64LP-SISITETM444691-12 In progressTa#64 Target DescriptionThursday, June 02, 2022, 16:54: 
Ta#64 LP-SIS target
 Ta#64_Target_Loading_Data.pdf 
  115   Wednesday, May 25, 2022, 10:15 Darwin Ortiz RosalesSiC#42HP-FEBIAD  44692-9 ReadyTarget SiC#42 DescriptionWednesday, May 25, 2022, 10:15 
 Description-SiC#42.png 
  114   Wednesday, November 10, 2021, 18:09 Aaron SchmidtTa#63LP-SISITETM444691-11 In progressTa#63  Ta#63 LP-SIS target
description: 
 Ta#63_Target_Loading_Data.pdf 
  113   Monday, November 08, 2021, 11:30 Darwin Ortiz RosalesUCx#36LP-SIS  44691-1 ReadyUCx#36_Target_Description    UCx#36_properties.png 
  112   Wednesday, September 29, 2021, 10:37 Darwin Ortiz RosalesUCx#35LP-IG-LIS  42218-5 ReadyUCx#35-Target_description 
 UCx#35_Target_Description_.png 
  111   Tuesday, September 21, 2021, 21:08 Darwin Ortiz RosalesC#3LP-SIS  44691-7 ReadyTarget C #3 Description Tuesday, September 21, 2021, 21:09
See attached file for target description.
 C#3_Target_description.png 
  110   Monday, September 13, 2021, 14:53 Darwin Ortiz RosalesSiC#41HP-SIS  42218-7 ReadyTarget SiC#41 DescriptionMonday, September 13, 2021, 14:52
 Screenshot_2021-09-13_144830.png 
  109   Monday, August 16, 2021, 11:02 John WongUCx#34LP-SISITWTM244691-544378-1ReadyTarget description Monday, August 16, 2021, 11:01
See attachments for the target description
and SEM images
 UCx#34_target_description.PNGUCx_34_SEM_Density_Measurements.pdf 
  108   Wednesday, June 23, 2021, 18:13 Aaron SchmidtTa#62LP-SISITETM444691-4 In progressTa#62 Target Description (2) Ta#62 LP-SIS target
description: (REPLACEMENT FOR 44139-10)
  
  107   Wednesday, June 09, 2021, 11:45 Darwin Ortiz RosalesUCx#33LP-SIS  44139-12 ReadyUCx#33-Target_description Cartridge with discs was further
heated in EVAP1 (eLog 271 Evaporator 1).
 UCx33-target_description.png 
  106   Thursday, April 08, 2021, 09:54 Aaron SchmidtTa#62LP-SIS  44139-10 ReadyTa#62 target descriptionTa#62 LP-SIS target description:
  
  105   Tuesday, March 16, 2021, 17:05 Luca EgoritiITE-TM4-UC#32-P2N-SISHP-SISITETM4--In progressUO2 discs cuttingThis afternoon, Darwin prepared in the
hot lab fume hood the two UO2 slurries to
be cut into P2N target discs. Later, I took
 UC32-P2N_material_info.jpgFume_hood.jpg 
  104   Thursday, November 12, 2020, 11:32 Darwin Ortiz RosalesUCx#31HP-SISITETM44416043822ReadyUCx#31-Target_description Target full name ITE-TM4-UC#  UCx31-target_description.png 
  103   Tuesday, October 27, 2020, 12:53 Aaron SchmidtNb#9LP-SISITETM444508-2 ReadyNb#9 LP-SIS target description Nb#9 LP-SIS target description:
 Nb#9_Target_Loading_data.pdf 
  102   Tuesday, October 06, 2020, 14:25 Aaron SchmidtTa#61LP-SISITETM444508-1 In progressTa#61 Target Description Ta#61 LP-SIS target
description:
  
  101   Tuesday, September 29, 2020, 11:50 Marla CervantesC#2LP-SISITWTM244139-9 In progressTarget C#2 Description  Tuesday, September 29, 2020, 11:49
See attached picture
 C2-Description.JPG 
  100   Thursday, June 04, 2020, 15:00 Marla CervantesC#1LP-SIS  43044-8 In progressTarget C#1 Description Thursday, June 04, 2020, 15:00
See attached picture
 C1-Description.PNG 
  99   Wednesday, April 15, 2020, 08:10 Darwin Ortiz RosalesSiC#40HP-SIS  42218-8 ReadyTarget SiC#40 DescriptionWednesday, April 15, 2020, 07:51
See attached picture for description 
 Annotation_2020-04-15_080836.png 
  98   Thursday, February 20, 2020, 08:11 Aaron SchmidtTa#60LP-SIS  44139-13 ReadyTa#60 Target Description Thursday, February 20, 2020, 08:07: 
Ta#60 LP-SIS target description:
 Ta#60_Loading_Data.pdf 
  97   Friday, November 29, 2019, 10:53 Darwin Ortiz RosalesSiC#39HP-FEBIAD TM242464-3 ReadyTarget SiC#39 DescriptionFriday, December 06, 2019, 15:34
Added SEM images (see attachment#2)
- JW
 SiC#39_description.PNGSiC39_SEM.pdf 
  96   Tuesday, November 19, 2019, 12:20 Darwin Ortiz RosalesUCx#30LP-SIS  44062-3  Ready UCx30-target_description    UCx#30.PNGUCx30-taret_description_revised.png 
  95   Monday, October 21, 2019, 12:38 Darwin Ortiz RosalesUCx#29LP-SIS  44062-6  ReadyUCx29-target_description   UCx#29.PNG 
  94   Friday, October 11, 2019, 09:26 Darwin Ortiz RosalesSiC#38HP-FEBIAD TM242464-4 ReadyTarget SiC#38 DescriptionFriday, October 11, 2019, 09:25
See attached picture for description.
 
 SiC#38.PNG 
  93   Wednesday, October 02, 2019, 11:18 Marla CervantesUCx#28LP-SIS  44062-4 ReadyUCx #28 Target description Wednesday, October 02, 2019, 11:17
Attached please find
 UCx28-target_description.JPG 
  92   Tuesday, September 17, 2019, 08:47 Aaron SchmidtTa#59LP-SIS TM244062-5 In progressTa#59 Target descriptionTuesday, September 17, 2019, 08:44: 
T
 Ta#59_Loading_Data.pdf 
  91   Tuesday, July 30, 2019, 15:52 Darwin Ortiz RosalesZrC#8LP-SISITETM243044-5 ReadyTarget description 
Tuesday, July 30, 2019, 15:50
See attachment for details
 ZrC8.pngZrC_8_SEM.pdf 
  90   Monday, July 22, 2019, 16:33 Marla CervantesUCx#27LP-SIS  49044-9 ReadyUCx#27 Target Description Monday, July 22, 2019, 16:31
Attached please find
 UCx#27.JPG 
  89   Friday, May 31, 2019, 16:11 Aaron SchmidtTa#58LP-SISITETM243044-442972-7ReadyTa#58 Target desription Ta#58 LP-SIS  Ta#58_Loading_data.pdf 
  88   Thursday, November 29, 2018, 14:23 Marla CervantesUCx#26LP-IG-LIS  42281-3 ReadyUCx#26 Target descriptionThursday, November 29, 2018, 14:20
Attached please find
 UCx_26-description.JPG 
  87   Monday, October 15, 2018, 07:36 Aaron SchmidtTa#57 ITETM441177-3  Ta#57 Target Description.(Laura Lambert: Evap 2 Elog ID: 404) Tuesday,
April 17, 2018, 10:20
  
  86   Friday, October 12, 2018, 17:14 John WongUCx#25LP-SIS    In progressUCx#25 Target DescriptionFriday, October 12, 2018, 17:11
See attachment for UCx#25 target
description.
 UCx#25_target_description.JPG 
  85   Monday, September 17, 2018, 11:39 John Wongnp-SiC#1LP-SIS  43044-1 Readynano-SiC#1 Target descriptionMonday, September 17, 2018, 11:32
See attachment for the target description.
Some notes about the target conditioning
 target_description.JPG 
  84   Monday, August 27, 2018, 17:11 John WongUCx#24LP-SIS    ReadyUCx#24 Target Description Monday, August 27, 2018, 17:09
See attachment for UCx#24 target
description
 Capture.JPG 
  83   Friday, July 13, 2018, 14:41 John WongUCx#23LP-FEBIAD-CTL    ReadyUCx#23 target descriptionFriday, July 13, 2018, 14:40
Target is ready for installation. 
See attachment for description
 UCx_23-target_description.JPG 
  82   Thursday, June 21, 2018, 11:34 Aaron SchmidtTa#56HP-SIS  42218-9 ReadyTa#56 target description Thursday, June 21, 2018, 11:33:
Ta#56 HP-SIS target
 Ta#56_Loading_Data.pdf 
  81   Monday, April 16, 2018, 09:55 Laura LambertUCx#22LP-SIS  42218-13 ReadyUCx#22 Target Description Monday, April 16, 2018, 09:53
Attached please find the UCx#22 target
description.
 target_description.JPG 
  80   Wednesday, September 27, 2017, 09:14 Laura LambertSiC#37HP-FEBIADITETM439530-10 ReadySiC#37 target description Wednesday, September 27, 2017, 09:13
See attachment for target description.

 
 Target_Description.JPG 
  79   Tuesday, September 26, 2017, 12:07 Laura LambertTa#54HP-SISITWTM242218-10 ReadyTa#54 target descriptionTuesday, September 26, 2017, 09:31
Ta#54 HP-SIS target description:
  
  78   Monday, August 21, 2017, 11:13 Laura LambertUCx#21LP-SIS  42218-15 ReadyUCx#21 Target Description Monday, August 21, 2017, 11:09
Attached please find
 target_description.JPG 
  77   Thursday, July 06, 2017, 15:36 Anders MjosTa#55LP-SIS  42218-11 ReadyTa#55 target descriptionTarget loaded by Matt yesterday
320 foils = 33.7832 g
4 x 20 packs = 9.1170 g
  
  76   Monday, June 26, 2017, 13:36 Laura LambertTa #53HP-SIS TM242218-6 ReadyTa#53 target description Monday, June 26, 2017, 13:32
Ta#53 HP-SIS target description:
  
  75   Wednesday, May 31, 2017, 09:53 Laura LambertTa# 52LP-SIS TM442218-14 In progressTa#52 target description Wednesday, May 31, 2017, 09:51
Ta#52 LP-SIS target description:
  
  74   Tuesday, May 30, 2017, 15:15 Laura LambertSiC#36HP-FEBIAD-CTL TM241369-10 ReadySiC#36 target description Tuesday, May 30, 2017, 15:12
See attachment for target
 SiC#36_Target_Description.JPG 
  73   Tuesday, May 16, 2017, 13:18 Laura LambertUCx#20LP-IG-LISITETM442218-1 ReadyUCx#20 Target Description Tuesday, May 16, 2017, 13:13
Attached please find
 target_description.JPG 
  72   Wednesday, March 08, 2017, 15:42 Laura LambertTa#51LP-SIS TM241790-4 In progressTa#51 target description Wednesday, March 08, 2017, 15:40
Ta#51 LP-SIS target description:
  
  71   Tuesday, March 07, 2017, 10:00 Laura LambertUCx#19LP-SIS TM442218-12 ReadyUCx#19 Target Description Tuesday, March 07, 2017, 09:54
Attached please find
 UCx#19_description.jpg 
  70   Friday, October 21, 2016, 13:47 Laura LambertUCx#18LP-SIS  41790-6 ReadyUCx#18 Target Description Friday, October 21, 2016, 13:46
Attached please find
 UCx#18_description.jpg 
  69   Tuesday, October 18, 2016, 12:06 Laura LambertTa#50LP-SIS  41790-5 ReadyTa#50 target descriptionTuesday, October 18, 2016, 10:12
Ta#50 LP-SIS target description:
  
  68   Friday, October 07, 2016, 16:27 John WongSiC#35HP-FEBIAD  39530-9 ReadySiC35 Target description Friday, October 07, 2016, 16:28
See attachment for the target description

 
 SiC35_target_description.JPG 
  67   Friday, September 02, 2016, 14:45 John WongSiC#34LP-IG-LIS  39814-V2-1 ReadySiC#34 Target Description  Friday, September 02, 2016, 14:43
See attachment for target description 

 
 SiC34_target_description.JPG 
  66   Tuesday, August 02, 2016, 15:42 Laura LambertTa # 49HP-SIS  41369-6 ReadyTa#49 target description Tuesday, August 02, 2016, 15:30
Ta#49 HP-SIS target description:
  
  65   Tuesday, August 02, 2016, 15:28 Laura LambertUCx#17LP-SIS  41790-3 ReadyUCx#17 Target Description Tuesday, August 02, 2016, 15:27
Attached please find
 UCx#17_description.jpg 
  64   Wednesday, June 29, 2016, 11:49 Laura LambertSiC # 33HP-SIS  41369-4 ReadySiC#33 target description Wednesday, June 29, 2016, 11:47
See attachment for target
 elog_target_description.JPG 
  63   Wednesday, June 08, 2016, 15:55 Laura LambertUCx#16LP-IG-LIS  40860-2 ReadyUCx#16 Target Description Wednesday, June 08, 2016, 15:52
Attached please find the UCx#16
 Target_Description.JPG 
  62   Tuesday, April 19, 2016, 11:33 Laura LambertTa # 48HP-SIS  41369-5 ReadyTa # 48 target description Tuesday, April 19, 2016, 11:24
Ta#48 HP-SIS target description:
  
  61   Friday, March 11, 2016, 10:18 Laura LambertTa # 47 ITETM4  SpentTa # 47 target desscriptionFriday, March 11, 2016, 10:13 
Ta#47 LP-SIS [new small center
  
  60   Friday, March 04, 2016, 14:57 Laura LambertUCx#15LP-SISITW 41077-1 ReadyUCx#15 Target Description Friday, March 04, 2016, 14:56
Attached please find the UCx#15
 UCx_15_description.jpg 
  59   Monday, October 26, 2015, 16:33 Laura LambertUCx#14LP-SIS  41077-5 ReadyUCx#14 Target Description Monday, October 26, 2015, 16:23
Attached please find
 Capture.JPG 
  58   Wednesday, September 30, 2015, 17:08 John WongTa # 46HP-SIS  41369-3 ReadyTa#46 target description

    

       
            
  
  57   Thursday, September 24, 2015, 13:42 Laura LambertSiC#32HP-FEBIAD  39530-5 ReadySiC#32 target description Thursday, September 24, 2015, 11:46
See attachment for target description.

 
 elog_snapshot.JPG 
  56   Thursday, September 10, 2015, 13:33 Laura LambertTa # 46HP-SIS  41369-3 ReadyTa#46 target description Thursday, September 10, 2015, 13:31
Ta#46 HP-SIS target description:
  
  55   Friday, July 10, 2015, 11:23 John WongUCx#13LP-IG-LISITETM440860-1 ReadyUCx#13 Target description Friday, July 10, 2015, 11:15
Attached please find the UCx#13 target
description.   
 UCx_13_target_description.PNG 
  54   Tuesday, July 07, 2015, 13:00 John WongZrC#7LP-SISITWTM241177-2 ReadyZrC#7 (backup1) target descriptionTuesday, July 07, 2015, 12:36 
Total no. discs = 422
Total packed length = 13.2 cm (measured
 ZrC#7_backup.PNGZrC_specification_(backup#1_WO#41177-2).xlsx 
  53   Monday, July 06, 2015, 12:18 John WongZrC#7LP-SISITWTM241177-1 FailedZrC#7 target description

    

       
            
  
  52   Wednesday, June 03, 2015, 10:55 Laura LambertZrC#7LP-SISITWTM241177-1 ReadyZrC#7 target description  Wednesday, June 03, 2015, 10:53
Total length packed = 12.3cm
See attachment for target description.
 target_production_elog_ZrC#7.JPGZrC#7_final_density.xlsx 
  51   Wednesday, April 29, 2015, 15:39 Laura LambertSiC#31HP-SIS  38817-7 ReadySiC#31 Target description Wednesday, April 29, 2015, 15:30
SiC#31 HP-SIS target description: 
 final_density_measurements.JPGdensity_measurements.xlsxSiC_density_Jan_10_'14_cast_-_Copy.xlsxSiC_density_Oct_31_'14_cast.xlsx 
  50   Friday, April 17, 2015, 16:00 Laura LambertUCx # 12LP-SISITWTM141177-2 ReadyUCx#12 Target Description Thursday, April 16, 2015, 14:07
See attachment for target description
 UCx_12_target_description.PNG 
  49   Wednesday, April 01, 2015, 11:27 Laura LambertTa # 45HP-SIS  38817-5 In UseTa#45 target description Wednesday, April 01, 2015, 11:25
Ta#45 HP-SIS target description:
  
  48   Thursday, November 06, 2014, 13:35 Laura LambertUCx # 11LP-SISITETM440282-5 ReadyUCx#11 Target Description Thursday, November 06, 2014, 13:29
See attachment for target description

 
 UCx_11_target_description.PNG 
  47   Thursday, September 25, 2014, 16:01 Laura LambertTa#44HP-SISITETM438817-940316-11ReadyTa#44 target descriptionThursday, September 25, 2014, 15:59
Ta#44 HP-SIS target description:
  
  46   Monday, August 18, 2014, 14:39 Laura LambertThO2 #1LP-SIS     ThO2 #1 Target DescriptionMonday, August 18, 2014, 14:53
See attachment for target description

 
 ThO2#1_target_description.JPG 
  45   Monday, July 28, 2014, 15:57 John WongZrC#6LP-SISITWTM140282-3 SpentZrC target description  Monday, July 28, 2014, 15:52
See attachment#1 for ZrC target description. 
Target is currently undergoing the
 ZrC#6.JPG 
  44   Tuesday, July 15, 2014, 11:01 Laura LambertUCx # 10LP-SISITETM439165-10 ReadyUCx#10 Target DescriptionTuesday, July 15, 2014, 10:58
See attachment for target description 
 UCx_10_target_description.PNG 
  43   Tuesday, July 15, 2014, 10:54 Laura LambertTa # 43LP-SISITWTM140282-2 ReadyTa # 43 Target Description Tuesday, July 15, 2014, 9:45
Ta#42 LP-SIS target description:
  
  42   Friday, June 06, 2014, 14:09 John WongUCx#9LP-SIS  39165-9 ReadyUCx#9 - Target description  Friday, June 06, 2014, 14:08
See attachment for the target description

 
 UCx#9_target_description_1.JPG 
  41   Wednesday, April 30, 2014, 16:36 John WongSiC#30HP-FEBIADITETM338481-8 SpentSiC#30 Target description Wednesday, April 30, 2014, 15:16
Note:
This target was built in 2011. 
 SiC#30_density_measurements.xlsx 
  40   Monday, March 31, 2014, 15:02 John WongTiC#4HP-SIS  38817-839956-10SpentTarget Description  Monday, March 31, 2014, 15:00
Target consists of 360 discs of TiC
+ graphite foils. 
 TiC#4_description.JPG 
  39   Monday, March 17, 2014, 16:15 John WongTa#42LP-SISITWTM440282-139956-1SpentTa#42 Target description Monday, March 17, 2014, 16:14
Ta#42 LP-SIS target description:
Total Ta foils = 400
  
  38   Wednesday, November 27, 2013, 17:56 John WongUCx#8LP-IG-LISITETM439814-IV SpentUCx#8 target description Wednesday, November 27, 2013, 17:49
UCx#8 target description - see attachment#1

 
 UCx_8_specification.PNG 
  37   Friday, October 25, 2013, 17:35 John WongTa#41HP-SISITWTM438817-10 SpentTa#41 target descriptionFriday, October 25, 2013, 17:35
Ta#41 HP-SIS target description:
Total Ta foils = 400
  
  36   Friday, August 30, 2013, 14:45 John WongNiO#2HP-FEBIAD  39530-639069-4SpentNiO target descriptionFriday, August 30, 2013, 14:38 
NiO/Ni#2                                            
Average
  
  35   Friday, August 30, 2013, 12:08 John WongUCx#7LP-SISITWTM138634-739230-4SpentUCx#7 - target descriptionFriday, August 30, 2013, 12:06
UCx#7 target specification, see attachment
#1.
 UCx#7_specifications.PNG 
  34   Wednesday, July 10, 2013, 18:41 John WongSiC#29HP-FEBIAD-CTLITETM438481-639956-4SpentSiC#29 - Target descriptionWednesday, July 10, 2013, 18:32 
SiC#29 HP-FEBIAD-CTL target description: 
Total SiC foils = 510 discs 
 SiC#29_density_measurements_final.xlsx 
  33   Thursday, May 30, 2013, 16:58 John WongUCx#6LP-SIS TM139165-639230-8SpentUCx#6 - target description  Thursday, May 30, 2013, 16:57
UCx#6 target specification, see attachment
#1. 
 UCx#6_specifications.PNG 
  32   Thursday, April 11, 2013, 14:30 John WongTa#39LP-SISITWTM139165-7 SpentTa#39 target descriptionTa#38 LP-SIS target description:
Total Ta foils = 400
Foil Thickness = 0.025mm
  
  31   Tuesday, March 19, 2013, 13:32 John WongSiC#28-RFQLP-SIS TM4LP-RFQ (NEW) SpentSiC#28-RFQ target description Tuesday, March 19, 2013, 12:28
SiC#28 - RFQ target description: 
Total SiC foils = 325 discs
 SiC#28_RFQ_density_measurements.xlsx 
  30   Tuesday, December 11, 2012, 15:44 Anders MjosSiCHP-FEBIADITWTM4nana (old style fittings)ReadyTest target for the Conditioning Station The target has been used for operator
training previously at the ISAC Test Stand.

    9-pin connector was completed
  
  29   Thursday, October 11, 2012, 11:41 John WongNiO#1HP-FEBIADITETM438481-739069-1/10(lid)SpentNiO target description (Should have posted this before my long
vacation... Anyway, it's for documentation)
Thursday, October 11, 2012, 11:38
  
  28   Wednesday, September 12, 2012, 01:53 John WongNb#7LP-SIS  39165-6 SpentNb#7 target description Wednesday, September 12, 2012, 02:10
Nb#7 target description: 
Total Nb foils = 400 discs
 Nb#7_target_description.jpg 
  27   Wednesday, August 29, 2012, 14:52 John WongUCx#5LP-SISITWTM439165-5 FailedUCx#5 target description Wednesday, August 29, 2012, 14:50
UCx#5 target description, see attachment#1
The target is currently undergoing
 UCx#5_specifications.PNG 
  26   Wednesday, August 01, 2012, 09:37 Pierre BricaultITE-TM4-UO#3LP-FEBIADITETM4  Problems/SolutionsShort has developed while lowering the cathode heater On tuesday July we lower the cathode
heater to swap the anode-cathode bias. While
lowering the cathode heater a short on the
  
  25   Friday, July 20, 2012, 11:39 John WongUCx#4LP-SISITWTM138634-936833-4SpentUCx#4 target descriptionFriday, July 20, 2012, 11:35
UCx#4 target description, see attachment#1
The target is assembled and stored
 UCx#4_specfications.PNG 
  24   Wednesday, July 04, 2012, 11:32 Anders MjosUO2/Nb #1LP-FEBIADITETM438481-939069-3Spenttarget assembled

    

       
            
 UO2#3_Anode_End_Cap.xlsx 
  23   Monday, June 11, 2012, 13:46 John WongNb#6LP-SISITWTM138634-436833-1SpentNb#5 run finished

    

       
            
  
  22   Friday, June 01, 2012, 11:43 John WongTa#38LP-SISITWTM139165-238633-2SpentTa#38 target descriptionTa#38 LP-SIS target description: 
Total Ta foils = 400
Foil thickness = 0.025mm
 Ta_38_EE_deposit.JPGTa#38_EE.PNGTa#38_CE.PNG 
  21   Thursday, May 24, 2012, 11:04 John WongSiC#27HP-SISITETM438817-339069-2SpentHP-SIS SiC27 target description Thursday, May 24, 2012, 10:34
SiC#27- HPSIS target description: 
Total SiC foils = 240 discs
 SiC#27_specification.png 
  20   Monday, February 20, 2012, 16:39 John WongUO2/Nb #1LP-FEBIADITETM438481-9 Spenttarget ready for assembly Monday, February 20, 2012, 16:25
Mass of empty target oven used =
461.55g
  
  19   Monday, February 13, 2012, 16:00 John WongNb#6LP-SISITWTM138634-436833-1SpentNb#5 ready in the Conditioning Station 

Monday, February 13, 2012,
16:00 
  
  18   Wednesday, November 16, 2011, 14:08 John WongUCx#3LP-SISITWTM138634-1036833-3SpentUCx#3 ready to go online Wednesday, November 16, 2011, 13:51
UCx#3 descriptions: 
Target oven wrapped with 3-Ta heat
 UCx#3_assembly.jpg 
  17   Monday, October 17, 2011, 14:45 John WongSiC#26HP-FEBIADITETM438295-938307-8SpentRun finished

    

       
            
 EE_after_teststand.jpgSiC#26_specification.png 
  16   Tuesday, September 27, 2011, 10:36 Anders MjosTaC#1LP-SISITETM138634-636833-6Problems/SolutionsMaterial deposited on Extraction Electrode after Test Stand

    

       
            
 Deposited_material.pdf 
  15   Friday, September 23, 2011, 17:03 Anders MjosSiC#26HP-FEBIADITETM438295-938307-8SpentRun finishedFriday, September 23, 2011, 16:54:

    Cu-gaskets used for leak
checking target had a leak rate of about 
  
  14   Tuesday, September 06, 2011, 13:19 John WongTaC#1LP-SISITETM138634-6 SpentTarget is doneTuesday, September 06, 2011, 13:14: 
Average mass = 0.206g
Average Thickness = 0.0189 cm
 TaC_density_measurements.xls 
  13   Tuesday, August 09, 2011, 14:31 John WongUCx#2LP-SISITWTM138634-838633-5SpentUCx#2 run is finished.UCx#2 Spec:
Target wrapped with 3 Ta-heat shields
Target length = 11.2cm
 broke_screwhead.jpgUCx#2.jpg 
  12   Wednesday, July 06, 2011, 14:32 John WongTa#36LP-SISITETM438634-238307-10SpentTarget ready, will go online on July 27Ta-LP-SIS (w.o#38634-2)
Target  consists of 400 Ta foils,
4.4 cm in length.  Total mass + Ta wire
  
  11   Wednesday, July 06, 2011, 14:29 John WongNb/SpareHP-SIS  38817-2 In progressTarget ready for AssemblyTarget oven w.o# 38817-2:
inner diameter: left = 18.29mm, right
= 18.16mm.
  
  10   Wednesday, July 06, 2011, 14:13 John WongTa#40HP-SIS  38295-4 SpentTarget description Details about Ta Hp surface, w.o#38295-4
(spare): 
This target was built as a spare.
  
  9   Friday, June 17, 2011, 11:58 John WongUCx (flakes)LP-SIS    Problems/SolutionsMaking UC2 flakes (stock# 2011_A & _B)Fri Jun 17 10:28:47 2011
First batch of UO2/C mixture of carbonization
(Stock# 2011_A):   
 8x 
  8   Thursday, June 16, 2011, 17:26 John WongNbHP-SIS  38817-1 SpentTarget is ready and stored in cabinet  Thu Jun 16 17:21:10 2011
Two targets of Nb-HP-SIS are complete
and ready to be installed in the heat shields:
  
  7   Friday, June 03, 2011, 09:16 John WongTa#37LP-SISITWTM138634-536833-7SpentTarget is done Fri Jun  3 12:40:30 2011
Ta#37-LP-SIS (w.o#38634-5)
Filled with 400 Ta foils (25/pk),
 EE.JPGEE-CuO.jpg 
  4   Thursday, March 31, 2011, 15:38 John WongSiC#25HP-SISITETM438481-138307-?SpentITE-TM4-SiC#25-Hp-SIS Thu Mar 31 15:19:51 2011:  SiC#25
was made sometime in December of 2010. 
It is now in the target module and ready
 big_mass_scan.jpg 
  3   Tuesday, March 29, 2011, 14:14 John WongTa#35HP-SISITETM438481-338303-4SpentITE-TM4-Ta#35-Hp-SIS ITE-TM4-Ta#35-Hp-SIS
Thu Apr  7 15:32:32 2011:
Target oven - w.o#38481-3.
 Ta-HPSIS.jpg 