Thursday, September 10, 2015, 13:33, Laura Lambert, Ta # 46, HP-SIS, , , 41369-3, , Ready, Ta#46 target description
|
Wednesday, September 30, 2015, 17:08, John Wong, Ta # 46, HP-SIS, , , 41369-3, , Ready, Ta#46 target description
|
|
Message ID: 56
Entry time: Thursday, September 10, 2015, 13:33
Reply to this: 58
|
Author: |
Laura Lambert |
Target/No.#: |
Ta # 46 |
Source: |
HP-SIS |
Station: |
|
Module: |
|
Target Oven W.O#: |
41369-3 |
Heat Shield W.O#: |
|
Status: |
Ready |
Subject: |
Ta#46 target description |
|
|
Thursday, September 10, 2015, 13:31
Ta#46 HP-SIS target description:
Total Ta foils = 505
Foil Thickness = 0.025mm
Target density = 15.85 g/cm3
Target length = 3.4cm
Total Mass = 75.2772g
|