Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 51     Entry time: Wednesday, April 29, 2015, 15:39
Author: Laura Lambert 
Target/No.#: SiC#31 
Source: HP-SIS 
Station:  
Module:  
Target Oven W.O#: 38817-7 
Heat Shield W.O#:  
Status: Ready 
Subject: SiC#31 Target description 

 Wednesday, April 29, 2015, 15:30

SiC#31 HP-SIS target description: 

Total SiC foils = 520 discs 

Total mass SiC + C_grv foils = 60.2441 g (before sintering, expecting ~13% loss of organic mass after burnt off) 

Average mass SiC/disc (without C_grv) = 0.0853g

Average thickness SiC (without C_grv) = 0.2093mm 

Total packed length = 17cm

See attachment #1 for the density measurement.  


 

Attachment 1: final_density_measurements.JPG  62 kB  Uploaded Monday, June 15, 2015, 15:47  | Show | Hide all
Attachment 2: density_measurements.xlsx  10 kB  Uploaded Monday, June 15, 2015, 16:42
Attachment 3: SiC_density_Jan_10_'14_cast_-_Copy.xlsx  13 kB  Uploaded Monday, June 15, 2015, 16:43
Attachment 4: SiC_density_Oct_31_'14_cast.xlsx  13 kB  Uploaded Monday, June 15, 2015, 16:43
ELOG V2.9.2-2455