Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 21     Entry time: Thursday, May 24, 2012, 11:04
Author: John Wong 
Target/No.#: SiC#27 
Source: HP-SIS 
Station: ITE 
Module: TM4 
Target Oven W.O#: 38817-3 
Heat Shield W.O#: 39069-2 
Status: Spent 
Subject: HP-SIS SiC27 target description 

 Thursday, May 24, 2012, 10:34

SiC#27- HPSIS target description: 

Total SiC foils = 240 discs

Total SiC+ C-grv = 27.79g

Total length = 8.3cm 

Average mass of SiC/disc (without C-grv) = 0.085g 

Average thickness of SiC (without C-grv) = 0.24mm  

No Rh foil added

Salt added = 10uL Li, 10uL Na 

see attachment#1: SiC#27_density measurements

see link for more details: http://documents.triumf.ca/docushare/dsweb/View/Collection-8530


 

Attachment 1: SiC#27_specification.png  44 kB  Uploaded Wednesday, September 30, 2015, 17:30  | Show | Hide all
ELOG V2.9.2-2455