Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 116     Entry time: Thursday, June 02, 2022, 16:55
Author: Aaron Schmidt 
Target/No.#: Ta#64 
Source: LP-SIS 
Station: ITE 
Module: TM4 
Target Oven W.O#: 44691-12 
Heat Shield W.O#:  
Status: In progress 
Subject: Ta#64 Target Description 

Thursday, June 02, 2022, 16:54: 

Ta#64 LP-SIS target description: 

Total Ta foils = 470 [6x20 packs + 350 single discs]

Foil Thickness = 0.0254mm (0.0010") Measured.

Target density = 12.005 g/cm3

Target length = 3.35 cm

Total Mass = 40.2166 g [Incl foils + Ta wire on 6 packs]

Total mass w/ Target oven= 446 g (w/ end caps)

Discs in target are arranged as follows: 1pack / 75 singles / 1pack / 100 singles / 2packs / 100 singles / 1pack / 75 singles / 1pack

End caps installed (Not expanded). No Ta foil heat shield added

 
Attachment 1: Ta#64_Target_Loading_Data.pdf  713 kB  Uploaded Tuesday, June 07, 2022, 15:30  | Show | Hide all
ELOG V2.9.2-2455