Wednesday, June 03, 2015, 10:55, Laura Lambert, ZrC#7, LP-SIS, ITW, TM2, 41177-1, , Ready, ZrC#7 target description 
|
Monday, July 06, 2015, 12:18, John Wong, ZrC#7, LP-SIS, ITW, TM2, 41177-1, , Failed, ZrC#7 target description
|
|
Message ID: 53
Entry time: Monday, July 06, 2015, 12:18
In reply to: 52
|
Author: |
John Wong |
Target/No.#: |
ZrC#7 |
Source: |
LP-SIS |
Station: |
ITW |
Module: |
TM2 |
Target Oven W.O#: |
41177-1 |
Heat Shield W.O#: |
|
Status: |
Failed |
Subject: |
ZrC#7 target description |
|
|
Laura Lambert wrote: |
Wednesday, June 03, 2015, 10:53
Total length packed = 12.3cm
See attachment for target description.
|
Monday, July 06, 2015, 12:10
This target did not pass the test-stand and will not be used for online (unless if it gets approved). The target container is deformed. An increase of voltage was observed during the test; perhaps it's a sign of the container being cracked?! See Test-stand e-log#450 for more details.
Another target is already prepared and being tested. (Target Oven WO# 41177-2).
|