Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Test-Stand, Page 24 of 53  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Datedown Author Target/No.# Source Station Module Target Oven W.O# Heat Shield W.O# Status Subject
  588   Friday, June 02, 2017, 15:57 Aaron SchmidtSiC#36HP-FEBIAD-CTLITWTM241369-1042132-6/9 Conditioning SiC#36

Friday, June 02, 2017, 15:20: Coil loose (Remove lid, Tighten and place lid again)

Friday, June 02, 2017, 15:52: Roughing

Friday, June 02, 2017, 16:13: Turbo pumps on.

Friday, June 02, 2017, 16:18: Ion gauge on

Friday, June 02, 2017, 16:23: RGA on 


By Anders

Saturday, June 03, 2017, 09:07: Opened HS water supply. In/out 95 / 10 psi. 3.8 lpm. Vacuum stable at 3.3E-7 Torr

Saturday, June 03, 2017, 09:08: Open IV4

Saturday, June 03, 2017, 09:32: Opening gas bottles. Source on. Reconfigured in Cathode bias

Saturday, June 03, 2017, 09:41: Started autoramping to 580 / 250 A at 2 A/min

Saturday, June 03, 2017, 09:42: COIL at 70 A, ANODE at 200 V

Saturday, June 03, 2017, 09:42: BIAS / EL / EE at 30 / 13 / 1.5 kV

Saturday, June 03, 2017, 09:47

Daqpro time 9:33

Device Flow [lpm] Temp [C]
HS + MSP 3.8 26
TBHT 3.1 27
COIL + EE 4.9 26
TGHT 5.5 26

 


Sunday, June 04, 2017, 06:52 : Source at TGHT / TBHT 580 / 290 A over night and outgassing while measuring mass 20. Both anode current andFC6 current increased whie vacuum decreased. Ramped TBHT up to 300 A. Anode current now 68 mA, FC6 0.2 nA, FC0 3 uA


Monday, June 05, 2017, 16:04: Starting cool down

Monday, June 05, 2017, 22:04: Source off. Stopped turbo pumps.


Tuesday, June 06, 2017, 07:28: RGA off.

Tuesday, June 06, 2017, 07:30: Venting

Attachment 1: 20170605-Anode-Coil_CHT-sweep.xlsx
Attachment 2: TS-2017-06-02-16-21.rga
Attachment 3: SiC#36.docx
Attachment 4: OMEGA_OM-DAQPRO-5300_06-Jun-17_09.30.24.dlp
Attachment 5: ITW-TM2-SiC#36-HP-CTL-FEBIAD_Test_Stand.docx
Attachment 6: ER-580-300-30kV-m20.txt
value (Voltage offset       0.0000)
     70.0000
      1.3000
    100.0000
  29978.0220
21
21
./emit.dat
 -0.1263 -0.0922 -0.0873 -0.0861 -0.0851 -0.0729 -0.0827 -0.0833 -0.0839 -0.0931 -0.0922 -0.0949 -0.0876 -0.0888 -0.0900 -0.0894 -0.0885 -0.0873 -0.0885 -0.0839 -0.0879
 -0.0665 -0.0842 -0.0824 -0.0836 -0.0827 -0.0668 -0.0775 -0.0781 -0.0815 -0.0888 -0.0873 -0.0900 -0.0830 -0.0854 -0.0854 -0.0858 -0.0833 -0.0827 -0.0854 -0.0790 -0.0812
 -0.0641 -0.0745 -0.0674 -0.0790 -0.0800 -0.0659 -0.0778 -0.0647 -0.0717 -0.0876 -0.0662 -0.0827 -0.0809 -0.0842 -0.0870 -0.0839 -0.0754 -0.0793 -0.0723 -0.0644 -0.0797
 -0.0635 -0.0748 -0.0720 -0.0781 -0.0763 -0.0641 -0.0769 -0.0769 -0.0711 -0.0858 -0.0729 -0.0833 -0.0815 -0.0803 -0.0815 -0.0839 -0.0797 -0.0793 -0.0726 -0.0641 -0.0815
 -0.0653 -0.0800 -0.0754 -0.0787 -0.0763 -0.0674 -0.0775 -0.0653 -0.0732 -0.0854 -0.0763 -0.0836 -0.0836 -0.0815 -0.0809 -0.0830 -0.0745 -0.0800 -0.0696 -0.0647 -0.0800
 -0.0671 -0.0800 -0.0635 -0.0797 -0.0766 -0.0684 -0.0778 -0.0668 -0.0717 -0.0861 -0.0772 -0.0858 -0.0858 -0.0827 -0.0787 -0.0818 -0.0760 -0.0812 -0.0708 -0.0662 -0.0800
 -0.0665 -0.0766 -0.0690 -0.0793 -0.0754 -0.0656 -0.0781 -0.0720 -0.0711 -0.0870 -0.0653 -0.0809 -0.0836 -0.0827 -0.0815 -0.0815 -0.0754 -0.0800 -0.0702 -0.0665 -0.0793
 -0.0659 -0.0748 -0.0714 -0.0784 -0.0751 -0.0623 -0.0784 -0.0677 -0.0705 -0.0882 -0.0699 -0.0690 -0.0781 -0.0815 -0.0815 -0.0830 -0.0769 -0.0793 -0.0742 -0.0647 -0.0797
 -0.0656 -0.0790 -0.0714 -0.0775 -0.0748 -0.0656 -0.0778 -0.0705 -0.0720 -0.0858 -0.0742 -0.0598 -0.0705 -0.0745 -0.0827 -0.0848 -0.0751 -0.0763 -0.0720 -0.0644 -0.0806
 -0.0659 -0.0800 -0.0699 -0.0790 -0.0769 -0.0653 -0.0797 -0.0699 -0.0708 -0.0836 -0.0647 -0.0711 -0.0589 -0.0742 -0.0760 -0.0845 -0.0754 -0.0809 -0.0699 -0.0659 -0.0827
 -0.0653 -0.0763 -0.0714 -0.0806 -0.0772 -0.0662 -0.0793 -0.0677 -0.0693 -0.0864 -0.0748 -0.0766 -0.0497 -0.0723 -0.0754 -0.0793 -0.0754 -0.0827 -0.0705 -0.0665 -0.0839
 -0.0659 -0.0781 -0.0684 -0.0790 -0.0772 -0.0638 -0.0772 -0.0739 -0.0717 -0.0858 -0.0763 -0.0763 -0.0586 -0.0613 -0.0742 -0.0790 -0.0742 -0.0797 -0.0708 -0.0659 -0.0833
 -0.0647 -0.0769 -0.0714 -0.0800 -0.0757 -0.0644 -0.0769 -0.0690 -0.0726 -0.0873 -0.0705 -0.0778 -0.0726 -0.0552 -0.0766 -0.0797 -0.0726 -0.0751 -0.0717 -0.0662 -0.0815
 -0.0650 -0.0787 -0.0717 -0.0800 -0.0760 -0.0671 -0.0781 -0.0702 -0.0726 -0.0885 -0.0754 -0.0809 -0.0763 -0.0632 -0.0751 -0.0824 -0.0726 -0.0757 -0.0711 -0.0653 -0.0803
 -0.0653 -0.0790 -0.0687 -0.0787 -0.0763 -0.0671 -0.0793 -0.0662 -0.0714 -0.0848 -0.0815 -0.0854 -0.0812 -0.0739 -0.0729 -0.0830 -0.0732 -0.0790 -0.0674 -0.0647 -0.0815
 -0.0656 -0.0778 -0.0748 -0.0769 -0.0757 -0.0653 -0.0781 -0.0763 -0.0684 -0.0864 -0.0775 -0.0842 -0.0827 -0.0797 -0.0757 -0.0800 -0.0769 -0.0790 -0.0684 -0.0647 -0.0830
 -0.0662 -0.0757 -0.0714 -0.0793 -0.0775 -0.0635 -0.0769 -0.0681 -0.0693 -0.0885 -0.0766 -0.0818 -0.0824 -0.0812 -0.0778 -0.0818 -0.0769 -0.0787 -0.0690 -0.0644 -0.0815
 -0.0638 -0.0763 -0.0748 -0.0790 -0.0772 -0.0635 -0.0754 -0.0711 -0.0714 -0.0861 -0.0748 -0.0836 -0.0830 -0.0815 -0.0790 -0.0848 -0.0751 -0.0766 -0.0690 -0.0641 -0.0797
 -0.0626 -0.0751 -0.0708 -0.0787 -0.0763 -0.0647 -0.0763 -0.0696 -0.0708 -0.0854 -0.0729 -0.0842 -0.0854 -0.0818 -0.0803 -0.0830 -0.0763 -0.0803 -0.0681 -0.0644 -0.0784
 -0.0629 -0.0748 -0.0674 -0.0784 -0.0751 -0.0659 -0.0778 -0.0705 -0.0699 -0.0845 -0.0757 -0.0845 -0.0821 -0.0803 -0.0812 -0.0815 -0.0729 -0.0803 -0.0690 -0.0659 -0.0781
 -0.0668 -0.0739 -0.0693 -0.0766 -0.0772 -0.0635 -0.0769 -0.0656 -0.0690 -0.0848 -0.0754 -0.0836 -0.0815 -0.0812 -0.0797 -0.0803 -0.0745 -0.0790 -0.0699 -0.0641 -0.0812
Attachment 7: CHT-290-AV-200-CI-70.txt
value (Voltage offset       0.0000)
     80.0000
      0.7000
    100.0000
  29978.0220
21
21
./emit.dat
 -0.1340 -0.0769 -0.0870 -0.0967 -0.0836 -0.0986 -0.0946 -0.0848 -0.0851 -0.0943 -0.0946 -0.0870 -0.0821 -0.0845 -0.0885 -0.0928 -0.0870 -0.0888 -0.0955 -0.0903 -0.0934
 -0.0729 -0.0699 -0.0809 -0.0931 -0.0793 -0.0937 -0.0885 -0.0775 -0.0793 -0.0888 -0.0912 -0.0815 -0.0775 -0.0803 -0.0818 -0.0879 -0.0812 -0.0821 -0.0900 -0.0873 -0.0888
 -0.0745 -0.0656 -0.0717 -0.0760 -0.0729 -0.0888 -0.0854 -0.0763 -0.0726 -0.0821 -0.0867 -0.0693 -0.0711 -0.0742 -0.0815 -0.0882 -0.0793 -0.0806 -0.0821 -0.0906 -0.0729
 -0.0766 -0.0668 -0.0681 -0.0824 -0.0739 -0.0830 -0.0870 -0.0781 -0.0757 -0.0827 -0.0790 -0.0696 -0.0705 -0.0656 -0.0812 -0.0867 -0.0732 -0.0827 -0.0677 -0.0702 -0.0687
 -0.0760 -0.0674 -0.0684 -0.0839 -0.0729 -0.0851 -0.0885 -0.0781 -0.0781 -0.0842 -0.0800 -0.0702 -0.0708 -0.0671 -0.0815 -0.0873 -0.0775 -0.0821 -0.0696 -0.0668 -0.0665
 -0.0735 -0.0690 -0.0687 -0.0708 -0.0754 -0.0854 -0.0879 -0.0784 -0.0797 -0.0848 -0.0812 -0.0775 -0.0726 -0.0723 -0.0800 -0.0867 -0.0757 -0.0824 -0.0729 -0.0674 -0.0677
 -0.0739 -0.0677 -0.0687 -0.0665 -0.0693 -0.0790 -0.0836 -0.0757 -0.0815 -0.0851 -0.0800 -0.0797 -0.0684 -0.0729 -0.0800 -0.0851 -0.0735 -0.0827 -0.0723 -0.0674 -0.0677
 -0.0742 -0.0671 -0.0659 -0.0702 -0.0763 -0.0732 -0.0714 -0.0589 -0.0650 -0.0851 -0.0778 -0.0702 -0.0687 -0.0674 -0.0806 -0.0864 -0.0702 -0.0821 -0.0708 -0.0681 -0.0684
 -0.0723 -0.0687 -0.0674 -0.0815 -0.0787 -0.0763 -0.0681 -0.0464 -0.0476 -0.0641 -0.0693 -0.0656 -0.0671 -0.0702 -0.0815 -0.0867 -0.0742 -0.0824 -0.0705 -0.0677 -0.0705
 -0.0708 -0.0671 -0.0656 -0.0827 -0.0787 -0.0815 -0.0757 -0.0458 -0.0455 -0.0583 -0.0586 -0.0589 -0.0629 -0.0702 -0.0818 -0.0876 -0.0769 -0.0827 -0.0699 -0.0681 -0.0687
 -0.0729 -0.0638 -0.0644 -0.0769 -0.0806 -0.0800 -0.0790 -0.0558 -0.0357 -0.0494 -0.0543 -0.0562 -0.0632 -0.0607 -0.0775 -0.0873 -0.0742 -0.0839 -0.0732 -0.0677 -0.0665
 -0.0732 -0.0665 -0.0638 -0.0720 -0.0745 -0.0790 -0.0797 -0.0604 -0.0446 -0.0424 -0.0485 -0.0613 -0.0623 -0.0668 -0.0732 -0.0781 -0.0708 -0.0830 -0.0674 -0.0674 -0.0659
 -0.0726 -0.0656 -0.0668 -0.0833 -0.0739 -0.0754 -0.0793 -0.0644 -0.0604 -0.0519 -0.0421 -0.0504 -0.0623 -0.0671 -0.0754 -0.0809 -0.0705 -0.0729 -0.0674 -0.0690 -0.0668
 -0.0732 -0.0693 -0.0677 -0.0839 -0.0790 -0.0827 -0.0818 -0.0668 -0.0671 -0.0632 -0.0458 -0.0455 -0.0574 -0.0665 -0.0809 -0.0854 -0.0708 -0.0778 -0.0668 -0.0632 -0.0687
 -0.0742 -0.0699 -0.0699 -0.0845 -0.0821 -0.0842 -0.0888 -0.0760 -0.0717 -0.0726 -0.0623 -0.0479 -0.0549 -0.0681 -0.0812 -0.0873 -0.0720 -0.0806 -0.0681 -0.0644 -0.0650
 -0.0735 -0.0677 -0.0690 -0.0781 -0.0836 -0.0873 -0.0879 -0.0766 -0.0818 -0.0830 -0.0732 -0.0580 -0.0610 -0.0674 -0.0800 -0.0873 -0.0739 -0.0824 -0.0739 -0.0650 -0.0644
 -0.0705 -0.0659 -0.0681 -0.0818 -0.0815 -0.0851 -0.0870 -0.0757 -0.0797 -0.0854 -0.0763 -0.0726 -0.0681 -0.0677 -0.0784 -0.0851 -0.0717 -0.0821 -0.0681 -0.0668 -0.0659
 -0.0726 -0.0647 -0.0659 -0.0833 -0.0757 -0.0812 -0.0858 -0.0754 -0.0793 -0.0861 -0.0763 -0.0674 -0.0687 -0.0720 -0.0797 -0.0861 -0.0726 -0.0803 -0.0681 -0.0684 -0.0681
 -0.0742 -0.0677 -0.0681 -0.0842 -0.0726 -0.0833 -0.0854 -0.0766 -0.0800 -0.0824 -0.0766 -0.0699 -0.0681 -0.0705 -0.0836 -0.0873 -0.0748 -0.0812 -0.0705 -0.0696 -0.0681
 -0.0735 -0.0671 -0.0702 -0.0848 -0.0735 -0.0830 -0.0861 -0.0775 -0.0821 -0.0839 -0.0790 -0.0717 -0.0720 -0.0693 -0.0800 -0.0876 -0.0748 -0.0815 -0.0677 -0.0674 -0.0650
 -0.0732 -0.0659 -0.0681 -0.0833 -0.0797 -0.0848 -0.0879 -0.0781 -0.0797 -0.0830 -0.0769 -0.0729 -0.0702 -0.0711 -0.0793 -0.0864 -0.0742 -0.0803 -0.0702 -0.0656 -0.0650
Attachment 8: 20170605_1029_emit_A40.txt
value (Voltage offset       0.0000)
     80.0000
      0.7000
    100.0000
  29978.0220
21
21
./emit.dat
 -0.1291 -0.0717 -0.0934 -0.0940 -0.0946 -0.0952 -0.0955 -0.0934 -0.0937 -0.0958 -0.0946 -0.0964 -0.0912 -0.0967 -0.0943 -0.0952 -0.0961 -0.0946 -0.0937 -0.0949 -0.0940
 -0.0696 -0.0690 -0.0876 -0.0916 -0.0894 -0.0916 -0.0916 -0.0870 -0.0894 -0.0919 -0.0903 -0.0919 -0.0879 -0.0909 -0.0919 -0.0900 -0.0888 -0.0888 -0.0876 -0.0912 -0.0906
 -0.0668 -0.0735 -0.0912 -0.0806 -0.0806 -0.0891 -0.0909 -0.0864 -0.0763 -0.0897 -0.0845 -0.0702 -0.0763 -0.0867 -0.0919 -0.0894 -0.0888 -0.0900 -0.0848 -0.0803 -0.0729
 -0.0656 -0.0674 -0.0702 -0.0580 -0.0842 -0.0882 -0.0903 -0.0870 -0.0824 -0.0870 -0.0821 -0.0644 -0.0626 -0.0812 -0.0885 -0.0909 -0.0879 -0.0894 -0.0812 -0.0665 -0.0681
 -0.0681 -0.0653 -0.0818 -0.0668 -0.0830 -0.0864 -0.0888 -0.0903 -0.0854 -0.0864 -0.0854 -0.0742 -0.0726 -0.0867 -0.0897 -0.0919 -0.0876 -0.0906 -0.0848 -0.0677 -0.0668
 -0.0681 -0.0681 -0.0858 -0.0687 -0.0824 -0.0879 -0.0900 -0.0876 -0.0897 -0.0873 -0.0867 -0.0705 -0.0790 -0.0903 -0.0922 -0.0928 -0.0882 -0.0861 -0.0827 -0.0693 -0.0677
 -0.0684 -0.0687 -0.0854 -0.0684 -0.0745 -0.0775 -0.0809 -0.0858 -0.0858 -0.0888 -0.0885 -0.0696 -0.0717 -0.0885 -0.0906 -0.0885 -0.0861 -0.0873 -0.0818 -0.0659 -0.0690
 -0.0677 -0.0693 -0.0842 -0.0656 -0.0790 -0.0601 -0.0461 -0.0449 -0.0558 -0.0833 -0.0851 -0.0684 -0.0699 -0.0836 -0.0894 -0.0885 -0.0867 -0.0879 -0.0815 -0.0662 -0.0681
 -0.0641 -0.0659 -0.0809 -0.0668 -0.0842 -0.0674 -0.0397 0.0027 -0.0125 -0.0400 -0.0626 -0.0650 -0.0751 -0.0879 -0.0912 -0.0903 -0.0879 -0.0897 -0.0842 -0.0690 -0.0681
 -0.0635 -0.0616 -0.0793 -0.0635 -0.0803 -0.0748 -0.0580 0.0098 0.0266 -0.0250 -0.0439 -0.0363 -0.0549 -0.0885 -0.0912 -0.0922 -0.0870 -0.0909 -0.0842 -0.0681 -0.0668
 -0.0687 -0.0613 -0.0809 -0.0610 -0.0748 -0.0757 -0.0656 -0.0302 0.0601 0.0275 -0.0293 -0.0360 -0.0531 -0.0656 -0.0800 -0.0888 -0.0888 -0.0867 -0.0839 -0.0665 -0.0656
 -0.0705 -0.0644 -0.0815 -0.0598 -0.0766 -0.0772 -0.0720 -0.0513 -0.0058 0.0369 0.0107 -0.0250 -0.0519 -0.0705 -0.0739 -0.0705 -0.0793 -0.0842 -0.0818 -0.0668 -0.0668
 -0.0696 -0.0650 -0.0818 -0.0693 -0.0800 -0.0763 -0.0775 -0.0665 -0.0424 0.0027 0.0269 -0.0131 -0.0500 -0.0720 -0.0772 -0.0772 -0.0766 -0.0757 -0.0784 -0.0665 -0.0684
 -0.0693 -0.0674 -0.0827 -0.0702 -0.0894 -0.0864 -0.0800 -0.0708 -0.0598 -0.0400 -0.0049 0.0021 -0.0476 -0.0732 -0.0800 -0.0848 -0.0790 -0.0812 -0.0745 -0.0586 -0.0665
 -0.0696 -0.0668 -0.0854 -0.0726 -0.0876 -0.0879 -0.0894 -0.0867 -0.0769 -0.0626 -0.0494 -0.0250 -0.0400 -0.0742 -0.0867 -0.0894 -0.0870 -0.0833 -0.0793 -0.0623 -0.0592
 -0.0684 -0.0693 -0.0827 -0.0677 -0.0842 -0.0848 -0.0864 -0.0891 -0.0845 -0.0848 -0.0729 -0.0461 -0.0473 -0.0671 -0.0845 -0.0900 -0.0848 -0.0858 -0.0833 -0.0650 -0.0626
 -0.0696 -0.0699 -0.0830 -0.0668 -0.0851 -0.0848 -0.0876 -0.0879 -0.0824 -0.0897 -0.0812 -0.0647 -0.0638 -0.0757 -0.0815 -0.0867 -0.0876 -0.0882 -0.0818 -0.0668 -0.0659
 -0.0702 -0.0668 -0.0839 -0.0690 -0.0842 -0.0870 -0.0897 -0.0845 -0.0845 -0.0851 -0.0812 -0.0681 -0.0717 -0.0854 -0.0854 -0.0861 -0.0842 -0.0867 -0.0827 -0.0687 -0.0684
 -0.0687 -0.0668 -0.0854 -0.0717 -0.0885 -0.0891 -0.0882 -0.0848 -0.0858 -0.0854 -0.0839 -0.0674 -0.0778 -0.0867 -0.0891 -0.0897 -0.0858 -0.0873 -0.0848 -0.0677 -0.0668
 -0.0687 -0.0647 -0.0864 -0.0674 -0.0854 -0.0897 -0.0888 -0.0873 -0.0867 -0.0885 -0.0839 -0.0684 -0.0739 -0.0879 -0.0897 -0.0900 -0.0903 -0.0888 -0.0833 -0.0668 -0.0656
 -0.0668 -0.0644 -0.0842 -0.0671 -0.0842 -0.0888 -0.0876 -0.0861 -0.0848 -0.0842 -0.0842 -0.0662 -0.0687 -0.0873 -0.0916 -0.0897 -0.0861 -0.0845 -0.0824 -0.0671 -0.0653
Attachment 9: 20170605_1024_emit_A40.txt
value (Voltage offset       0.0000)
     70.0000
      1.3000
    100.0000
  29978.0220
21
21
./emit.dat
 -0.1505 -0.0943 -0.0912 -0.0958 -0.0925 -0.0778 -0.0784 -0.0763 -0.0766 -0.0906 -0.0879 -0.0903 -0.0922 -0.0906 -0.0937 -0.0934 -0.0946 -0.0922 -0.0952 -0.0931 -0.0955
 -0.0595 -0.0888 -0.0842 -0.0906 -0.0848 -0.0705 -0.0723 -0.0717 -0.0729 -0.0833 -0.0830 -0.0861 -0.0842 -0.0845 -0.0903 -0.0891 -0.0903 -0.0854 -0.0906 -0.0867 -0.0903
 -0.0714 -0.0815 -0.0797 -0.0873 -0.0888 -0.0735 -0.0708 -0.0739 -0.0693 -0.0784 -0.0821 -0.0827 -0.0861 -0.0800 -0.0836 -0.0870 -0.0781 -0.0876 -0.0806 -0.0659 -0.0897
 -0.0699 -0.0769 -0.0534 -0.0851 -0.0848 -0.0598 -0.0711 -0.0659 -0.0653 -0.0809 -0.0751 -0.0781 -0.0812 -0.0800 -0.0842 -0.0882 -0.0803 -0.0897 -0.0790 -0.0684 -0.0903
 -0.0732 -0.0839 -0.0644 -0.0836 -0.0885 -0.0671 -0.0690 -0.0815 -0.0677 -0.0815 -0.0766 -0.0815 -0.0800 -0.0848 -0.0821 -0.0864 -0.0742 -0.0903 -0.0812 -0.0668 -0.0912
 -0.0729 -0.0891 -0.0681 -0.0864 -0.0864 -0.0702 -0.0696 -0.0769 -0.0690 -0.0800 -0.0726 -0.0815 -0.0861 -0.0812 -0.0833 -0.0839 -0.0772 -0.0885 -0.0824 -0.0684 -0.0906
 -0.0732 -0.0861 -0.0732 -0.0873 -0.0876 -0.0674 -0.0690 -0.0717 -0.0681 -0.0793 -0.0607 -0.0714 -0.0861 -0.0809 -0.0830 -0.0876 -0.0800 -0.0876 -0.0800 -0.0671 -0.0912
 -0.0739 -0.0833 -0.0708 -0.0885 -0.0870 -0.0604 -0.0684 -0.0699 -0.0647 -0.0800 -0.0620 -0.0351 -0.0598 -0.0793 -0.0854 -0.0897 -0.0797 -0.0885 -0.0800 -0.0656 -0.0906
 -0.0754 -0.0858 -0.0653 -0.0882 -0.0903 -0.0671 -0.0684 -0.0644 -0.0638 -0.0784 -0.0674 -0.0204 -0.0140 -0.0558 -0.0824 -0.0876 -0.0781 -0.0888 -0.0806 -0.0659 -0.0912
 -0.0763 -0.0867 -0.0668 -0.0897 -0.0894 -0.0687 -0.0684 -0.0735 -0.0626 -0.0751 -0.0674 -0.0418 0.0314 -0.0415 -0.0555 -0.0851 -0.0757 -0.0900 -0.0800 -0.0720 -0.0900
 -0.0754 -0.0867 -0.0705 -0.0900 -0.0864 -0.0677 -0.0693 -0.0668 -0.0659 -0.0735 -0.0681 -0.0507 0.0629 -0.0208 -0.0577 -0.0656 -0.0769 -0.0873 -0.0812 -0.0714 -0.0894
 -0.0745 -0.0839 -0.0693 -0.0882 -0.0864 -0.0656 -0.0702 -0.0745 -0.0681 -0.0723 -0.0653 -0.0601 -0.0052 0.0259 -0.0586 -0.0677 -0.0641 -0.0891 -0.0827 -0.0656 -0.0903
 -0.0763 -0.0809 -0.0644 -0.0861 -0.0867 -0.0665 -0.0699 -0.0717 -0.0632 -0.0797 -0.0644 -0.0656 -0.0400 0.0293 -0.0558 -0.0720 -0.0684 -0.0781 -0.0772 -0.0662 -0.0894
 -0.0793 -0.0827 -0.0653 -0.0882 -0.0864 -0.0693 -0.0711 -0.0668 -0.0656 -0.0809 -0.0757 -0.0681 -0.0577 -0.0064 -0.0433 -0.0797 -0.0705 -0.0839 -0.0708 -0.0671 -0.0906
 -0.0763 -0.0873 -0.0687 -0.0882 -0.0876 -0.0693 -0.0702 -0.0806 -0.0665 -0.0803 -0.0766 -0.0812 -0.0735 -0.0455 -0.0415 -0.0790 -0.0732 -0.0848 -0.0739 -0.0656 -0.0879
 -0.0739 -0.0848 -0.0690 -0.0858 -0.0864 -0.0650 -0.0702 -0.0702 -0.0696 -0.0797 -0.0726 -0.0797 -0.0848 -0.0684 -0.0562 -0.0739 -0.0745 -0.0867 -0.0760 -0.0620 -0.0864
 -0.0748 -0.0833 -0.0665 -0.0876 -0.0833 -0.0644 -0.0708 -0.0693 -0.0687 -0.0769 -0.0751 -0.0803 -0.0845 -0.0793 -0.0797 -0.0784 -0.0775 -0.0879 -0.0812 -0.0623 -0.0873
 -0.0760 -0.0839 -0.0674 -0.0885 -0.0851 -0.0668 -0.0729 -0.0742 -0.0662 -0.0781 -0.0739 -0.0797 -0.0815 -0.0800 -0.0833 -0.0858 -0.0769 -0.0879 -0.0803 -0.0681 -0.0885
 -0.0766 -0.0815 -0.0687 -0.0876 -0.0870 -0.0699 -0.0702 -0.0717 -0.0662 -0.0784 -0.0757 -0.0797 -0.0815 -0.0787 -0.0806 -0.0851 -0.0775 -0.0888 -0.0781 -0.0693 -0.0870
 -0.0751 -0.0824 -0.0702 -0.0888 -0.0867 -0.0671 -0.0677 -0.0702 -0.0665 -0.0797 -0.0742 -0.0790 -0.0815 -0.0812 -0.0824 -0.0839 -0.0775 -0.0885 -0.0787 -0.0677 -0.0879
 -0.0742 -0.0842 -0.0674 -0.0827 -0.0861 -0.0653 -0.0684 -0.0705 -0.0668 -0.0803 -0.0732 -0.0787 -0.0821 -0.0784 -0.0836 -0.0858 -0.0763 -0.0879 -0.0793 -0.0671 -0.0873
  587   Wednesday, May 24, 2017, 11:12 Anders Mjos      Problems/SolutionsFEBIAD Anode bias configuration

 The Test Stand has been configured for Anode bias. John Chow changed the power supply and the electrical connections have been wired according to ISK4523D REV 6.

 

Wednesday, May 24, 2017, 17:37: Anode current reduce to 285 A. Anode drain current limited  to a maximum of 300 A. This will be left overnight to see if there is an increase in anode drain current. as was seen today.

Attachment 1: 20170524-ST-currentvscoil-CHT300A.PNG
20170524-ST-currentvscoil-CHT300A.PNG
  586   Monday, May 22, 2017, 09:43 Aaron Schmidt HP-FEBIAD-CTL     Tri-Coil CTL-FEBIAD test IV

Monday, May 22, 2017, 09:41: Roughing.

Monday, May 22, 2017, 10:00: Turbo pumps started.


Tuesday, May 23, 2017, 07:45: Power/sources on.

Tuesday, May 23, 2017, 07:58: BIAS / EZL / EE @ 35 / 13 / 1.5 kV .

Tuesday, May 23, 2017, 08:19: Coil @ 50 A . Anode @ 200 V

Tuesday, May 23, 2017, 08:20: Auto ramping TGHT / TBHT to 580 / 270 A @ 2 A per min.

Tuesday, May 23, 2017, 10:22: IV4 opened.

Tuesday, May 23, 2017, 10:57: Increased ramping rate for TGHT to 4 A/min - AM

Tuesday, May 23, 2017, 19:05: Cooling down target for change to Anode bias tomorrow. - AM

Tuesday, May 23, 2017, 21:04: BIAS/EZL/EE off


Wednesday, May 24, 2017, 07:16: IV4 Closed.

Wednesday, May 24, 2017, 07:18: Power/Sources off.

Changed to Anode Bias.

Wednesday, May 24, 2017, 11:00: Coil @ 50 A . Anode @ 200 V

Wednesday, May 24, 2017, 11:02: Auto ramping TGHT / TBHT to 580 / 270 A @ 4 / 2 A per min.

Wednesday, May 24, 2017, 11:09: BIAS / EZL / EE @ 35 / 13 / 1.5 kV .


Tuesday, May 30, 2017, 07:02: Auto Cooling @ 2A/min


Thursday, June 01, 2017, 14:08: IV4 Closed. RGA off.

Thursday, June 01, 2017, 14:10: Ion gauge off. Turbos off.

Thursday, June 01, 2017, 16:51: Venting

Thursday, June 01, 2017, 21:16: Roughing.

Attachment 1: CTL_FEBIAD_Test_IV.docx
Attachment 2: TS-2017-05-22-10-07.rga
Attachment 3: TS-2017-05-25-15-42.rga
  585   Wednesday, May 17, 2017, 10:17 Anders Mjos HP-FEBIAD-CTL    Problems/SolutionsSparking between new coil line and ground electrode

Wednesday, May 17, 2017, 10:17: Sparking around 20 kV. Will need to vent to increase gap between water lines.

Turbos stopped.

Wednesday, May 17, 2017, 10:50: Reset IV4.

Wednesday, May 17, 2017, 10:59: Venting.

Wednesday, May 17, 2017, 11:42: Increased clearance to GND electrode.

Wednesday, May 17, 2017, 11:42: Roughing

Wednesday, May 17, 2017, 12:01: Turbos started

 

  584   Tuesday, May 16, 2017, 14:25 Aaron Schmidt HP-FEBIAD-CTL     Tri-Coil CTL-FEBIAD test III

Coil loose (Remove lid, Tighten and place lid again)

Tuesday, May 16, 2017, 14:24: Roughing.

Tuesday, May 16, 2017, 14:45: Turbo pumps on.


Wednesday, May 17, 2017, 06:53: RGA on. Vacuum @ 7.40e-07T

Wednesday, May 17, 2017, 08:04: Open waterline FS#5. OK. Vacuum @ 6.93e-07T

Wednesday, May 17, 2017, 08:05: Open waterline FS#4. OK.

Wednesday, May 17, 2017, 08:06: Open waterline FS#2. OK.

Wednesday, May 17, 2017, 08:07: Open waterline FS#3. OK.

Wednesday, May 17, 2017, 08:10: Vacuum @ 6.93e-07T. No response on RGA

Wednesday, May 17, 2017, 08:26: RGA Error out. Restart RGA.

Wednesday, May 17, 2017, 08:35: Vacuum ok @ 6.87e-07T. RGA ok.


Sparking issues


Wednesday, May 17, 2017, 13:00:

BIAS / EZL / EE @ 35 / 13 / 1.5 kV .

Coil @ 50 A . Anode @ 200 V

RGA Fatal errors. unable to restart. Reboot in morning.

Wednesday, May 17, 2017, 14:25: Auto ramping TGHT / TBHT to 300 / 150 A @ 2/1 A per min.

Wednesday, May 17, 2017, 15:05: BIAS / EZL / EE @ 30 / 13 / 1.5 kV .


Thursday, May 18, 2017, 08:27: Auto ramping TGHT / TBHT to 400 / 200 A @ 2/1 A per min.

Thursday, May 18, 2017, 08:33: RGA on.

Thursday, May 18, 2017, 08:37: IV4 opened

Thursday, May 18, 2017, 08:42: Optics on/set


Monday, May 22, 2017, 07:55: RGA, Power/Sources off.

Monday, May 22, 2017, 07:59: Turbo pumps, Ion gauge off.

Monday, May 22, 2017, 09:03: Venting

Monday, May 22, 2017, 09:40: 6 block screws tightened.

Attachment 1: CTL_FEBIAD_Test_target_III.docx
Attachment 2: TS-2017-05-17-13-00.rga
Attachment 3: TS-2017-05-17-13-30.rga
Attachment 4: TS-2017-05-18-08-30.rga
Attachment 5: CTL_FEBIAD_Test_target_II_(Spark_out).docx
Attachment 6: TS-2017-05-17-06-55.rga
Attachment 7: TS-2017-05-17-08-30.rga
Attachment 8: TS-2017-05-17-12-33.rga
  583   Wednesday, May 10, 2017, 15:07 Aaron Schmidt       Pump down empty chamber. (FS#3 out)

FS#3 lines blanked off.

Wednesday, May 10, 2017, 14:40: Roughing

Wednesday, May 10, 2017, 15:05: Turbos on.

Wednesday, May 10, 2017, 15:10: Ion gauge on.


Disconnect Leak detector. Connect He to FS#3 (G) line.

Thursday, May 11, 2017, 07:44: RGA on.

Thursday, May 11, 2017, 08:23: Vacuum @ 1.85e-06T. He line pressurized to 50 PSI. Monitor RGA.

Thursday, May 11, 2017, 09:07: No response on RGA. Vacuum @ 1.85e-06T. Purge Helium.

Hook up dry system leak detector to leak check valve behind turbo.

Leak rate: 0.0e-09 atm-cc/sec on detector. T.P: 0.0e-04T.

Thursday, May 11, 2017, 09:18: Open check valve. Vacuum ok @ 1.76e-06T

Base leak rate: 2.5e-09 atm-cc/sec.

Thursday, May 11, 2017, 09:25: Open He & Pressurize to 50 PSI.

Thursday, May 11, 2017, 09:30: Base leak rate dropping slowly: 2.0e-09 atm-cc/sec. No leak detected. No response on RGA.

Thursday, May 11, 2017, 09:35: Base leak rate dropping slowly: 1.7e-09 atm-cc/sec. No leak detected. No response on RGA.

Thursday, May 11, 2017, 09:45: Base leak rate Ok: 1.7e-09 atm-cc/sec. No leak detected. No response on RGA. Close check valve. Purge line. Vent detector.

Leak detector on. Leak rate: 0.0e-09 atm-cc/sec on detector. T.P: 0.0e-04T.

Thursday, May 11, 2017, 13:24: Open check valve. Vacuum @ 1.41e-06T

Base leak rate: @.2.0e-09 atm-cc/sec.

Thursday, May 11, 2017, 13:30: Open He & Pressurize to 50 PSI.

Thursday, May 11, 2017, 13:37: Base leak rate dropping slowly: 1.0e-09 atm-cc/sec. No leak detected. No response on RGA.

Thursday, May 11, 2017, 13:40: Base leak rate Ok: 0.1e-09 atm-cc/sec. No leak detected. No response on RGA. Vent He.

Connect spray nozzle to He. Vacuum issue noticed on RGA: N & O. Check for leak on Chamber


Tuesday, May 16, 2017, 08:45: RGA off. Ion gauge off. Turbos off

Tuesday, May 16, 2017, 09:50: Venting

Attachment 1: 05-11-2017_Water_leak.docx
  582   Friday, May 05, 2017, 14:28 Aaron SchmidtUC#20LP-IG-LIS     Conditioning Heat shield for UC#20 (2)

New O-rings installed on FS#3.

Friday, May 05, 2017, 14:24: Roughing.

Friday, May 05, 2017, 14:34: Waterlines reconnected to air lines. He likely still in lines. May show in RGA if there's an issue prior to opening the waterlines.

Friday, May 05, 2017, 14:47: Turbos started.

Friday, May 05, 2017, 17:59: Water leak still present on FS#3


Monday, May 08, 2017, 08:54: Line re-route on FS#3. Return line on (F) re-routed to Return line on (K). (EE)

Monday, May 08, 2017, 09:00: Open water into line FS#3 wait 10 minutes. Vacuum @ 4.52e-07T.

Monday, May 08, 2017, 09:12: Vacuum @ 4.52e-07T. Lines purged. No response on Vacuum or RGA.

Monday, May 08, 2017, 09:20: Line re-route on FS#3 through (K) supply to (G) & return on (E)

Monday, May 08, 2017, 09:28: Vacuum increased to 6.41e-07T. Response noticed on RGA. FS#3 purged & closed.

Monday, May 08, 2017, 09:30: Slow Vacuum increase to 6.67e-07T & climbing.

Monday, May 08, 2017, 10:13: Vacuum has decreased.

Monday, May 08, 2017, 10:26: Line re-route on FS#3 through (K) supply to (H) & return on (F).

Monday, May 08, 2017, 10:20: Open water into line FS#3 wait 10 minutes. Vacuum @ 4.69e-07T.

Monday, May 08, 2017, 10:30: Vacuum @ 4.60e-07T. Lines purged. No response on Vacuum or RGA.

Monday, May 08, 2017, 10:39: Spike on RGA while tightening (G)

Monday, May 08, 2017, 12:02: RGA off. Ion gauge & turbos off

Monday, May 08, 2017, 14:14: Vented. Lines adapted to leak detector on line (G) of FS#3. Line (E) blanked off. Check for leaks.

Monday, May 08, 2017, 14:49: Roughing.

Further purging of the lines required. Leak detector unable to achieve vacuum in the lines. Adapters removed. Line re-route on FS#3 through (K) supply to (G) & return on (E) for purge.


Tuesday, May 09, 2017, 07:30: Venting & Purging. Purge for a minimum of 20 mins.

Attach adapters. Hook up leak detector

Tuesday, May 09, 2017, 09:24: Leak found @ (G) line block

The (G) block line was disconnected and 'Blanked' off. The (G) line, block to feed through, was re-tested. No leak was found on blank off.

O-ring area cleaned. O-ring replaced. Blank removed. Block to Coil end reconnected. Leak highest when He sprayed directly on block.

Masking tape and/or 'putty' added block to block & confirm solder joint ok.

(E)(G) line removed. Block to block leak/sealing issue confirmed. (G) block leaks on the seat. (E) block ok. Tested externally. Achieves 1.0e-09 leak rate.


Wednesday, May 10, 2017, 09:22: Test stand (G) line from block to feed through has a separate leak. Cannot achieve below e-04 leak rate. Does not fully seal.


Removed heat shield to condition in evaporator 2.

Attachment 1: UC#20_Heat_shield_conditioning-2.docx
Attachment 2: TS-2017-05-05-17-11.rga
Attachment 3: TS-2017-05-11-07-50.rga
  581   Thursday, May 04, 2017, 13:49 Aaron SchmidtUC#20LP-IG-LIS     Conditioning Heat shield for UC#20 (1)

Thursday, May 04, 2017, 13:48: Roughing.

Thursday, May 04, 2017, 14:09: Turbos on.


Friday, May 05, 2017, 07:35: RGA on. Vacuum @ 1.56e-06T

Friday, May 05, 2017, 07:37: Waterlines opened gradually. Vacuum increased to 1.64e-06T. Response noted on RGA.

Friday, May 05, 2017, 07:45: Vacuum Increase into e-05T range. All waterlines turned off & purged.

Friday, May 05, 2017, 08:00: Vacuum decreased to 1.85e-06T.

Friday, May 05, 2017, 08:22: Open lines one by one & monitor. Vacuum @ 1.76e-06T.

Friday, May 05, 2017, 08:26: FS#4 TBHT cooling: Ok, No response.

Friday, May 05, 2017, 08:27: FS#2 TGHT cooling: Ok, No response.

Friday, May 05, 2017, 08:28: FS#5 HS cooling: Ok, No response.

Friday, May 05, 2017, 08:30: FS#3 EE cooling: Ok, No response.

Friday, May 05, 2017, 08:35: No immediate response.

Friday, May 05, 2017, 08:37: Vacuum spike into e-05T range.

Open lines one by one @ 10 minute intervals & monitor. Vacuum @ 1.56e-06T.

Friday, May 05, 2017, 09:30: FS#4 TBHT cooling: Ok @ 10 minutes. No RGA Response. Vacuum @ 1.56e-06T.

Friday, May 05, 2017, 09:40: FS#2 TGHT cooling: Ok @ 10 minutes. No RGA Response. Vacuum @ 1.56e-06T.

Friday, May 05, 2017, 09:50: FS#5 HS cooling: Ok @ 10 minutes. No RGA Response. Vacuum @ 1.56e-06T.

Friday, May 05, 2017, 10:00: FS#3 EE cooling

Friday, May 05, 2017, 10:01: No response @ 1 minute. Vacuum @ 1.56e-06T.

Friday, May 05, 2017, 10:02: No response @ 2 minutes. Vacuum @ 1.56e-06T.

Friday, May 05, 2017, 10:05: No response @ 5 minutes. Vacuum @ 1.56e-06T. Ok @ 6 min. ok @ 7 min.

Friday, May 05, 2017, 10:10: No response @ 5 minutes. Vacuum @ 1.56e-06T.

Friday, May 05, 2017, 10:11:39: Vacuum Increasing.

Friday, May 05, 2017, 10:12: Supply/Return closed. All lines purged.

Friday, May 05, 2017, 10:13: Vacuum @ 3.82e-06T and increasing.

Friday, May 05, 2017, 10:20: Vacuum @ 1.25e-05T. Line FS#3 closed.

Friday, May 05, 2017, 11:04: RGA off. Vacuum @ 1.56e-06T.

Friday, May 05, 2017, 11:05: Ion gauge. Turbos off.

Friday, May 05, 2017, 12:03: He lined into cooling. Venting.

Attachment 1: UC#20_Heat_shield_conditioning-1.docx
Attachment 2: TS-2017-05-05-07-35.rga
  580   Tuesday, May 02, 2017, 14:03 Aaron Schmidt       Pump down empty chamber. (FS#3 out)

Check to fit lines FS#3

Tuesday, May 02, 2017, 14:00: Rouging. 


Wednesday, May 03, 2017, 07:07: Venting.

Check final fit. Mark up FS#3.

Wednesday, May 03, 2017, 08:11: Roughing.

Wednesday, May 03, 2017, 12:42: Venting.


Thursday, May 04, 2017, 13:35: FS#3 re-installed.

Thursday, May 04, 2017, 13:47: Roughing  w/ UC#20 IG-LIS heat shield.

Attachment 1: 20170504_133718.jpg
20170504_133718.jpg
Attachment 2: 20170504_133723.jpg
20170504_133723.jpg
Attachment 3: 20170504_133728.jpg
20170504_133728.jpg
Attachment 4: 20170504_133735.jpg
20170504_133735.jpg
  579   Tuesday, April 18, 2017, 07:46 Aaron Schmidt      Problems/SolutionsTSG:TP1B & TSG:BV1B tripped

Tuesday, April 18, 2017, 07:30: TSG : TP1B Tripped on Saturday.

Tuesday, April 18, 2017, 07:40: TSG : BV1B opened. TSG : TP1B restarted.

Tuesday, April 18, 2017, 07:48: TSG : TP1B failed to restart.Turn off.

Tuesday, April 18, 2017, 07:59: TSG : BV1B opened. TSG : TP1B restart attempt. No audible response detected.

Tuesday, April 18, 2017, 08:01: The turbo pump is off and BV1B closed. Fault report entered #9815.

Tuesday, April 18, 2017, 09:40: Ion gauge, remaining turbo pump off.

Tuesday, April 18, 2017, 13:00: Vacuum Group arrival to change TSG : TP1B.

Once the turbo pump cooling line was loosened slightly, a slight water leak occurred. Line snapped. Water leak. Valves to all turbo pump cooling closed.


***NOTE*** - From Thursday, November 24, 2016, 08:05: TMS:TP2

Friday, November 25, 2016, 14:45: Turbos at speed. Vacuum at 1.9E-5 T

*** Note *** : One of the copper cooling lines was leaking. The line was fixed. Monitor. <---- Due to this recurring issue, the decision was made to air cool the turbo pumps.


Tuesday, April 18, 2017, 14:10: Air cooling to replace water cooling. TSG : TP1A already has air cooling. Replace the cooling on the other 3 of 4 turbo pumps.

Tuesday, April 18, 2017, 15:27: All turbo pump cooling replaced with air cooling. TSG : TP1B successfully replaced.


Wednesday, April 19, 2017, 07:57: Roughing.

Wednesday, April 19, 2017, 09:01: Turbo pumps on. Bypass made on water flow (Still air cooled overall)

Wednesday, April 19, 2017, 09:15: TSG :TP1A accidentally tripped. Restarted.

Wednesday, April 19, 2017, 09:42: Both turbo pumps off. Unable to achieve proper vacuum.

Wednesday, April 19, 2017, 11:04: Roughing.

Wednesday, April 19, 2017, 11:44: TSG :TP1A on.

Wednesday, April 19, 2017, 11:51: TSG :TP1B on.

 

Attachment 1: Cooling_&_Turbo_Replacement.docx
  578   Wednesday, April 12, 2017, 16:04 Anders Mjos      Problems/SolutionsLeak on FS#3 COIL and EE

A water to vacuum leak has been found on FS#3. The leak is not detected on the leak detector, but can be seen as an increase in vacuum and on partial water pressure on the RGA

Wednesday, April 12, 2017, 17:11: The leak is on circuit EG (Coil +). Confirmed with water pressure

Wednesday, April 12, 2017, 17:21: RGA off. Turbos stopped.


Wednesday, April 19, 2017, 13:00: Leak detector hooked up to TS. (Check Turbo)

Wednesday, April 19, 2017, 14:00: He to FS#3.

Wednesday, April 19, 2017, 14:31: Minimal response on leak detector. No response on RGA.

Wednesday, April 19, 2017, 14:36: Manual valve closed. Leak detector off. RGA off.

Wednesday, April 19, 2017, 14:37: FS#3 purged.

Wednesday, April 19, 2017, 14:39: Ion gauge off. Turbos off.

Wednesday, April 19, 2017, 14:44: Leak detector disconnected.


Thursday, April 20, 2017, 07:35: Venting

Thursday, April 20, 2017, 09:10: TRI-COIL CTL-FEBIAD removed.

Thursday, April 20, 2017, 09:23: Water lines (E) (G) removed w/ block. 

Thursday, April 20, 2017, 09:30: Roughing.

Thursday, April 20, 2017, 10:04: Turbos on.

Thursday, April 20, 2017, 13:15: Leak detector attached & turned on.

Thursday, April 20, 2017, 13:25: Water lines FS#5 opened to create loop. Pressurized @ 30 PSI.

Thursday, April 20, 2017, 13:45: RGA on.

Thursday, April 20, 2017, 13:58: All lines opened, purged, and re-pressurized @ 30 PSI with He.

Thursday, April 20, 2017, 14:15: Minimal response on Leak detector. No response on RGA.


Friday, April 21, 2017, 07:26: Vacuum @ 4.87E-07T. No He response on RGA. Lines still pressurized @ 30 PSI of Helium.

Friday, April 21, 2017, 10:19: Vacuum level close, but not optimal after 24 hrs. 2e-07T range is optimal.

Friday, April 21, 2017, 10:22: Adjustment of Turbo (TSG:TP1B) flanges. Stud Flange to Chamber (loose nuts found). brief vacuum spike noted.

Friday, April 21, 2017, 10:27: Turbo pump flange to Stud Flange tightened. No change on vacuum.

Friday, April 21, 2017, 10:41: Test Stand Exhaust cleaned. Clog noticed. Monitor Vacuum


Monday, April 24, 2017, 10:24: Three leaks found on FS#3. Two on the soldered ends of the VCRS (Mid-line) and one on the block. Requires repair/replacement.


Tuesday, May 02, 2017, 08:32 : RGA off.

Tuesday, May 02, 2017, 08:33: Ion gauge & Turbos off.

Tuesday, May 02, 2017, 12:55: Venting

Attachment 1: 2017-04-12_COIL_Leak_IG1.png
2017-04-12_COIL_Leak_IG1.png
Attachment 2: 2017-04-12_COIL_Leak_RGA.png
2017-04-12_COIL_Leak_RGA.png
Attachment 3: 4-18-2017_TP1B_&_water_leak.docx
  577   Monday, April 10, 2017, 15:12 Anders Mjos      Problems/SolutionsVacuum leak on front door

The vacuum behaved erratic over night with excursion up into the mid 10^-6 Torr range. To investigate the chamber was vented. With the doors open, the o-rings and sealing surfaces were cleaned. When pumping down again a vacuum leak could be heard at the front door by the lock. The chamber was vented again twice, finally the two o-rings were swapped. This removed the large leak. The door is prevented from contacting the box at the lock, which is likely the source of the leak.

  576   Thursday, April 06, 2017, 12:06 Aaron Schmidt HP-FEBIAD-CTL    In progressTri-Coil CTL-FEBIAD test

Thursday, April 06, 2017, 12:06: Roughing.

Thursday, April 06, 2017, 13:07: Turbo pumps on.

Thursday, April 06, 2017, 13:18: Ion gauge on.

Thursday, April 06, 2017, 13:25: RGA filament error FL5. RESET RGA.

Thursday, April 06, 2017, 13:34: RGA on.


Friday, April 07, 2017, 08:35: Waterlines opened. No response on RGA. Vacuum @ 3.24e-07T


Monday, April 10, 2017, 11:51: Vacuum unstable. Venting to investigate.

Monday, April 10, 2017, 11:52: Turbos stopped.

Monday, April 10, 2017, 14:57: Roughing.

Monday, April 10, 2017, 15:18: Turbos started.

Monday, April 10, 2017, 15:23: TP1 at speed. Opened gases.

Monday, April 10, 2017, 15:26: Turbos at speed. Vacuum at 2.0E-5 T


Tuesday, April 11, 2017, 16:55  : Stopped turbos.

Tuesday, April 11, 2017, 17:01: Venting through turbos to replace seals on HS

Tuesday, April 11, 2017, 17:48: Turbos started


Thursday, April 20, 2017, 09:10: Assembly removed from test stand.

  575   Tuesday, April 04, 2017, 14:33 Aaron Schmidt       Power supply failure to E-rig

Wednesday, March 29, 2017, 15:15: DAC power supply appears to have failed. Pop sound and electrical smoke/smell noticed.


Tuesday, April 04, 2017, 14:15: Kepco BOP 500M power supply replaced with back up Kepco BOP 500M.

Tuesday, April 04, 2017, 14:32: No response from new power supply. All connections in OK. Further inquiry required.

It has been determined, due to the damage shown in the uploaded pictures, that theis power supply will need replacing.
Attachment 1: 20170330_094009.jpg
20170330_094009.jpg
Attachment 2: 20170330_094019.jpg
20170330_094019.jpg
Attachment 3: 20170407_115355.jpg
20170407_115355.jpg
Attachment 4: 20170407_115223.jpg
20170407_115223.jpg
Attachment 5: 20170407_115414.jpg
20170407_115414.jpg
  574   Friday, March 24, 2017, 14:43 Aaron SchmidtTa#51LP-SISITWTM241790-441751-5In progressConditioning Ta#51

Friday, March 24, 2017, 15:40: Roughing.

Friday, March 24, 2017, 15:59: Turbo pumps on.

Friday, March 24, 2017, 16:04: Ion gauge on.

Friday, March 24, 2017, 16:07: RGA on. Turbo pumps @ speed.


Monday, March 27, 2017, 09:07: Water lines opened. No response on RGA. Vacuum @ 1.81e-07T

Monday, March 27, 2017, 09:10: Power on.

Monday, March 27, 2017, 09:50: Troubleshooting: Sources/Optics non-responsive. Controls group notified.

Monday, March 27, 2017, 11:16: Optics all green minus the magnet TMS : MB1. PLC issue reported.

Monday, March 27, 2017, 11:30: PLC reboot. Brief whiteout on screens. Screen function returned. TMS : MB1 still interlocked.

Monday, March 27, 2017, 14:30: TMS : MB1 no longer interlocked. Optics non-responsive to 'P/S On'. Voltages can be adjust while optics are 'in black'


Tuesday, March 28, 2017, 09:30: Optics still have error but can be run.

Tuesday, March 28, 2017, 09:43: BIAS / EZL / EE @ 30 / 13 / 1.5 kV . Spark noted while bring up BIAS.

Tuesday, March 28, 2017, 09:45: IV4 opened.

Tuesday, March 28, 2017, 11:13: RGA Fatal error. Restarted 11:15.

Tuesday, March 28, 2017, 12:57: Optics ok.

Device Temp
[C]
 Flow
[lpm]
 HS + MSP 27.5 3.89
 TBHT 27.3 3.00
 COIL + EE 27.1 4.94
 TGHT  27.1 5.59

Tuesday, March 28, 2017, 13:01: Auto ramping TGHT / TBHT to 300 / 100 A @ 2A per min.

Tuesday, March 28, 2017, 15:52: TGHT / TBHT @ 300 / 100. Vacuum @ 2.16e-07T

Device Temp
[C]
 Flow
[lpm]
 HS + MSP 27.5 3.85
 TBHT 26.7 3.12
 COIL + EE 25.8 4.92
 TGHT  26.5 5.59

 


Wednesday, March 29, 2017, 08:25: Auto ramping TGHT / TBHT to 580 / 200 A @ 2A per min.

Wednesday, March 29, 2017, 11:23: TMS : MB1 set from 'Reverse' to 'Normal' manually. Interlock Reset. (Mass Scan ok).

Device Temp
[C]
 Flow
[lpm]
 HS + MSP 36.9 3.82
 TBHT 27.2 3.07
 COIL + EE 27.4 4.97
 TGHT  29.4 5.58

Wednesday, March 29, 2017, 13:09: Auto ramping TBHT to 220 A @ 2A per min.

Wednesday, March 29, 2017, 13:20: Source page @ 218.9A - Read back on power supply @ 219A. Fatal Error on RGA.

Wednesday, March 29, 2017, 13:27: Manually ramp TBHT to 230 A @ 2A per min (approx).

Wednesday, March 29, 2017, 15:15: DAC power supply appears to have failed. Pop sound and electrical smoke/smell noticed. 

Wednesday, March 29, 2017, 15:28: Auto cooling TBHT to 220 A @ 2A per min.


Thursday, March 30, 2017, 08:42: Auto-cooling @ 2A per min.


Friday, March 31, 2017, 08:35: IV4 closed.

Friday, March 31, 2017, 08:44: Power/sources off.

Friday, March 31, 2017, 08:46: Ion gauge, Turbos off. Waterlines purged.


Thursday, April 06, 2017, 10:40: Venting

Attachment 1: ER-580-230-30kV-M22.txt
value (Voltage offset       0.0000)
     80.0000
      0.7000
     80.0000
  29978.0220
21
21
./emit.dat
 -0.1138 -0.0684 -0.0720 -0.0696 -0.0681 -0.0662 -0.0662 -0.0668 -0.0671 -0.0763 -0.0684 -0.0696 -0.0702 -0.0705 -0.0674 -0.0674 -0.0690 -0.0674 -0.0772 -0.0684 -0.0668
 -0.0650 -0.0668 -0.0659 -0.0653 -0.0620 -0.0626 -0.0653 -0.0635 -0.0653 -0.0726 -0.0665 -0.0674 -0.0644 -0.0677 -0.0635 -0.0656 -0.0644 -0.0620 -0.0717 -0.0641 -0.0684
 -0.0632 -0.0647 -0.0638 -0.0632 -0.0638 -0.0638 -0.0650 -0.0650 -0.0635 -0.0629 -0.0635 -0.0653 -0.0647 -0.0635 -0.0659 -0.0626 -0.0638 -0.0613 -0.0604 -0.0626 -0.0656
 -0.0616 -0.0647 -0.0641 -0.0656 -0.0571 -0.0641 -0.0644 -0.0650 -0.0620 -0.0610 -0.0638 -0.0626 -0.0613 -0.0635 -0.0656 -0.0629 -0.0650 -0.0620 -0.0623 -0.0644 -0.0638
 -0.0598 -0.0653 -0.0629 -0.0702 -0.0656 -0.0629 -0.0638 -0.0635 -0.0629 -0.0632 -0.0616 -0.0693 -0.0677 -0.0626 -0.0644 -0.0647 -0.0644 -0.0626 -0.0732 -0.0650 -0.0623
 -0.0616 -0.0668 -0.0644 -0.0662 -0.0665 -0.0635 -0.0626 -0.0629 -0.0626 -0.0647 -0.0656 -0.0665 -0.0644 -0.0644 -0.0632 -0.0641 -0.0629 -0.0659 -0.0613 -0.0607 -0.0595
 -0.0632 -0.0626 -0.0632 -0.0674 -0.0632 -0.0659 -0.0641 -0.0623 -0.0653 -0.0644 -0.0656 -0.0687 -0.0623 -0.0632 -0.0623 -0.0613 -0.0629 -0.0650 -0.0598 -0.0598 -0.0598
 -0.0623 -0.0592 -0.0568 -0.0705 -0.0635 -0.0613 -0.0629 -0.0626 -0.0653 -0.0650 -0.0616 -0.0674 -0.0577 -0.0635 -0.0650 -0.0607 -0.0610 -0.0604 -0.0623 -0.0623 -0.0644
 -0.0650 -0.0595 -0.0613 -0.0629 -0.0641 -0.0629 -0.0626 -0.0644 -0.0650 -0.0613 -0.0586 -0.0684 -0.0626 -0.0616 -0.0620 -0.0623 -0.0668 -0.0623 -0.0632 -0.0656 -0.0656
 -0.0650 -0.0620 -0.0638 -0.0659 -0.0677 -0.0623 -0.0632 -0.0620 -0.0632 -0.0595 -0.0616 -0.0705 -0.0693 -0.0623 -0.0616 -0.0629 -0.0665 -0.0613 -0.0610 -0.0647 -0.0638
 -0.0629 -0.0638 -0.0668 -0.0729 -0.0607 -0.0632 -0.0601 -0.0601 -0.0607 -0.0620 -0.0620 -0.0705 -0.0671 -0.0623 -0.0647 -0.0641 -0.0632 -0.0604 -0.0668 -0.0629 -0.0626
 -0.0607 -0.0653 -0.0635 -0.0635 -0.0653 -0.0629 -0.0610 -0.0613 -0.0632 -0.0638 -0.0659 -0.0702 -0.0635 -0.0626 -0.0653 -0.0623 -0.0604 -0.0598 -0.0620 -0.0623 -0.0626
 -0.0598 -0.0659 -0.0616 -0.0623 -0.0638 -0.0620 -0.0620 -0.0613 -0.0616 -0.0635 -0.0638 -0.0681 -0.0644 -0.0604 -0.0656 -0.0616 -0.0613 -0.0613 -0.0638 -0.0635 -0.0632
 -0.0629 -0.0610 -0.0598 -0.0687 -0.0635 -0.0629 -0.0638 -0.0616 -0.0610 -0.0604 -0.0623 -0.0638 -0.0653 -0.0620 -0.0632 -0.0595 -0.0632 -0.0650 -0.0659 -0.0647 -0.0641
 -0.0629 -0.0595 -0.0632 -0.0690 -0.0650 -0.0635 -0.0616 -0.0604 -0.0595 -0.0577 -0.0583 -0.0702 -0.0613 -0.0647 -0.0598 -0.0635 -0.0647 -0.0653 -0.0696 -0.0595 -0.0620
 -0.0638 -0.0613 -0.0641 -0.0684 -0.0620 -0.0616 -0.0610 -0.0604 -0.0632 -0.0583 -0.0595 -0.0720 -0.0635 -0.0638 -0.0626 -0.0604 -0.0650 -0.0632 -0.0629 -0.0583 -0.0604
 -0.0610 -0.0623 -0.0613 -0.0690 -0.0613 -0.0607 -0.0601 -0.0610 -0.0626 -0.0595 -0.0580 -0.0674 -0.0632 -0.0644 -0.0644 -0.0620 -0.0641 -0.0629 -0.0647 -0.0601 -0.0632
 -0.0635 -0.0595 -0.0638 -0.0647 -0.0644 -0.0632 -0.0623 -0.0638 -0.0632 -0.0577 -0.0549 -0.0656 -0.0641 -0.0632 -0.0638 -0.0601 -0.0635 -0.0607 -0.0623 -0.0644 -0.0671
 -0.0650 -0.0616 -0.0632 -0.0662 -0.0684 -0.0635 -0.0644 -0.0635 -0.0620 -0.0607 -0.0574 -0.0644 -0.0601 -0.0589 -0.0635 -0.0641 -0.0616 -0.0616 -0.0641 -0.0650 -0.0644
 -0.0620 -0.0659 -0.0629 -0.0674 -0.0653 -0.0644 -0.0632 -0.0620 -0.0626 -0.0607 -0.0613 -0.0674 -0.0610 -0.0598 -0.0641 -0.0635 -0.0626 -0.0623 -0.0650 -0.0613 -0.0607
 -0.0595 -0.0641 -0.0623 -0.0653 -0.0632 -0.0647 -0.0635 -0.0601 -0.0613 -0.0626 -0.0650 -0.0690 -0.0613 -0.0623 -0.0665 -0.0638 -0.0613 -0.0644 -0.0601 -0.0620 -0.0601
Attachment 2: ER-580-230-30kV-M38.txt
value (Voltage offset       0.0000)
     80.0000
      0.7000
     80.0000
  29978.0220
21
21
./emit.dat
 -0.1169 -0.0748 -0.0684 -0.0653 -0.0705 -0.0720 -0.0681 -0.0693 -0.0677 -0.0766 -0.0677 -0.0668 -0.0668 -0.0687 -0.0690 -0.0674 -0.0690 -0.0690 -0.0784 -0.0711 -0.0699
 -0.0665 -0.0693 -0.0690 -0.0626 -0.0681 -0.0662 -0.0629 -0.0638 -0.0610 -0.0717 -0.0677 -0.0650 -0.0638 -0.0616 -0.0665 -0.0656 -0.0638 -0.0659 -0.0754 -0.0674 -0.0659
 -0.0671 -0.0635 -0.0668 -0.0647 -0.0659 -0.0659 -0.0604 -0.0653 -0.0635 -0.0745 -0.0659 -0.0677 -0.0647 -0.0647 -0.0623 -0.0674 -0.0665 -0.0653 -0.0623 -0.0623 -0.0641
 -0.0699 -0.0644 -0.0656 -0.0690 -0.0623 -0.0641 -0.0656 -0.0635 -0.0656 -0.0668 -0.0650 -0.0662 -0.0650 -0.0650 -0.0632 -0.0650 -0.0629 -0.0613 -0.0677 -0.0665 -0.0653
 -0.0702 -0.0635 -0.0684 -0.0647 -0.0723 -0.0650 -0.0647 -0.0641 -0.0674 -0.0644 -0.0632 -0.0668 -0.0620 -0.0638 -0.0656 -0.0653 -0.0632 -0.0601 -0.0623 -0.0668 -0.0665
 -0.0671 -0.0629 -0.0659 -0.0677 -0.0674 -0.0656 -0.0641 -0.0638 -0.0668 -0.0613 -0.0632 -0.0693 -0.0604 -0.0647 -0.0647 -0.0656 -0.0632 -0.0626 -0.0632 -0.0638 -0.0635
 -0.0659 -0.0620 -0.0684 -0.0638 -0.0690 -0.0635 -0.0620 -0.0620 -0.0632 -0.0647 -0.0635 -0.0668 -0.0696 -0.0662 -0.0659 -0.0668 -0.0650 -0.0665 -0.0668 -0.0620 -0.0586
 -0.0644 -0.0629 -0.0650 -0.0684 -0.0629 -0.0616 -0.0613 -0.0647 -0.0620 -0.0647 -0.0644 -0.0650 -0.0751 -0.0635 -0.0659 -0.0732 -0.0595 -0.0644 -0.0650 -0.0629 -0.0623
 -0.0653 -0.0647 -0.0662 -0.0668 -0.0620 -0.0595 -0.0626 -0.0641 -0.0650 -0.0632 -0.0598 -0.0729 -0.0620 -0.0623 -0.0626 -0.0620 -0.0613 -0.0632 -0.0632 -0.0620 -0.0650
 -0.0681 -0.0659 -0.0684 -0.0687 -0.0629 -0.0632 -0.0653 -0.0620 -0.0656 -0.0613 -0.0616 -0.0702 -0.0714 -0.0610 -0.0629 -0.0638 -0.0638 -0.0626 -0.0668 -0.0638 -0.0635
 -0.0699 -0.0638 -0.0677 -0.0644 -0.0641 -0.0644 -0.0650 -0.0629 -0.0607 -0.0595 -0.0616 -0.0708 -0.0674 -0.0607 -0.0644 -0.0613 -0.0641 -0.0641 -0.0671 -0.0629 -0.0629
 -0.0687 -0.0613 -0.0638 -0.0659 -0.0635 -0.0632 -0.0626 -0.0610 -0.0613 -0.0620 -0.0650 -0.0677 -0.0681 -0.0616 -0.0653 -0.0641 -0.0635 -0.0647 -0.0620 -0.0607 -0.0616
 -0.0677 -0.0601 -0.0659 -0.0650 -0.0626 -0.0610 -0.0635 -0.0604 -0.0616 -0.0647 -0.0647 -0.0653 -0.0620 -0.0635 -0.0644 -0.0656 -0.0613 -0.0629 -0.0632 -0.0635 -0.0632
 -0.0659 -0.0623 -0.0668 -0.0653 -0.0623 -0.0610 -0.0626 -0.0623 -0.0702 -0.0623 -0.0620 -0.0702 -0.0723 -0.0616 -0.0635 -0.0638 -0.0610 -0.0604 -0.0659 -0.0653 -0.0629
 -0.0644 -0.0650 -0.0699 -0.0674 -0.0632 -0.0638 -0.0626 -0.0647 -0.0638 -0.0571 -0.0601 -0.0653 -0.0720 -0.0616 -0.0635 -0.0604 -0.0629 -0.0638 -0.0653 -0.0668 -0.0647
 -0.0662 -0.0632 -0.0665 -0.0671 -0.0641 -0.0635 -0.0620 -0.0647 -0.0626 -0.0577 -0.0562 -0.0641 -0.0662 -0.0635 -0.0647 -0.0650 -0.0616 -0.0644 -0.0671 -0.0595 -0.0607
 -0.0665 -0.0610 -0.0659 -0.0656 -0.0613 -0.0610 -0.0610 -0.0616 -0.0610 -0.0604 -0.0574 -0.0665 -0.0665 -0.0644 -0.0635 -0.0647 -0.0644 -0.0623 -0.0647 -0.0595 -0.0595
 -0.0656 -0.0623 -0.0653 -0.0684 -0.0613 -0.0592 -0.0629 -0.0635 -0.0629 -0.0620 -0.0589 -0.0659 -0.0714 -0.0595 -0.0613 -0.0629 -0.0635 -0.0626 -0.0656 -0.0613 -0.0620
 -0.0662 -0.0653 -0.0671 -0.0696 -0.0598 -0.0610 -0.0644 -0.0650 -0.0635 -0.0647 -0.0604 -0.0656 -0.0638 -0.0595 -0.0638 -0.0629 -0.0613 -0.0613 -0.0665 -0.0647 -0.0641
 -0.0696 -0.0629 -0.0644 -0.0705 -0.0629 -0.0647 -0.0635 -0.0656 -0.0626 -0.0616 -0.0620 -0.0656 -0.0601 -0.0629 -0.0604 -0.0635 -0.0613 -0.0598 -0.0644 -0.0629 -0.0635
 -0.0699 -0.0626 -0.0632 -0.0677 -0.0629 -0.0641 -0.0620 -0.0595 -0.0623 -0.0626 -0.0616 -0.0659 -0.0626 -0.0629 -0.0626 -0.0647 -0.0610 -0.0601 -0.0650 -0.0650 -0.0620
Attachment 3: ER-580-230-30kV-M133.txt
value (Voltage offset       0.0000)
     80.0000
      0.7000
     80.0000
  29978.0220
21
21
./emit.dat
 -0.0662 -0.0671 -0.0674 -0.0693 -0.0681 -0.0693 -0.0674 -0.0693 -0.0717 -0.0690 -0.0684 -0.0662 -0.0653 -0.0616 -0.0665 -0.0674 -0.0665 -0.0662 -0.0763 -0.0702 -0.0742
 -0.0665 -0.0726 -0.0665 -0.0696 -0.0677 -0.0684 -0.0656 -0.0693 -0.0681 -0.0626 -0.0677 -0.0644 -0.0653 -0.0589 -0.0671 -0.0671 -0.0635 -0.0626 -0.0739 -0.0656 -0.0650
 -0.0662 -0.0732 -0.0699 -0.0702 -0.0699 -0.0705 -0.0711 -0.0677 -0.0623 -0.0635 -0.0635 -0.0644 -0.0647 -0.0653 -0.0659 -0.0644 -0.0610 -0.0592 -0.0604 -0.0610 -0.0583
 -0.0641 -0.0671 -0.0650 -0.0702 -0.0726 -0.0601 -0.0693 -0.0662 -0.0644 -0.0610 -0.0601 -0.0659 -0.0620 -0.0674 -0.0632 -0.0613 -0.0607 -0.0623 -0.0650 -0.0604 -0.0662
 -0.0671 -0.0632 -0.0671 -0.0650 -0.0665 -0.0626 -0.0684 -0.0638 -0.0629 -0.0616 -0.0623 -0.0668 -0.0613 -0.0598 -0.0543 -0.0610 -0.0638 -0.0641 -0.0650 -0.0620 -0.0644
 -0.0684 -0.0656 -0.0693 -0.0668 -0.0684 -0.0726 -0.0702 -0.0635 -0.0659 -0.0671 -0.0671 -0.0647 -0.0635 -0.0574 -0.0604 -0.0644 -0.0644 -0.0632 -0.0684 -0.0635 -0.0650
 -0.0674 -0.0726 -0.0677 -0.0656 -0.0668 -0.0690 -0.0699 -0.0159 -0.0644 -0.0656 -0.0641 -0.0705 -0.0607 -0.0671 -0.0641 -0.0641 -0.0638 -0.0626 -0.0632 -0.0635 -0.0620
 -0.0668 -0.0699 -0.0684 -0.0671 -0.0665 -0.0659 -0.0699 -0.0641 -0.0610 -0.0607 -0.0577 -0.0665 -0.0632 -0.0638 -0.0638 -0.0638 -0.0629 -0.0604 -0.0626 -0.0623 -0.0629
 -0.0690 -0.0668 -0.0684 -0.0684 -0.0665 -0.0668 -0.0659 -0.0613 -0.0629 -0.0613 -0.0607 -0.0711 -0.0644 -0.0610 -0.0626 -0.0620 -0.0623 -0.0595 -0.0601 -0.0623 -0.0674
 -0.0674 -0.0668 -0.0659 -0.0684 -0.0696 -0.0656 -0.0677 -0.0650 -0.0644 -0.0598 -0.0635 -0.0729 -0.0616 -0.0610 -0.0620 -0.0623 -0.0607 -0.0638 -0.0626 -0.0620 -0.0626
 -0.0635 -0.0647 -0.0665 -0.0668 -0.0681 -0.0665 -0.0693 -0.0644 -0.0653 -0.0626 -0.0632 -0.0708 -0.0644 -0.0623 -0.0650 -0.0623 -0.0604 -0.0644 -0.0647 -0.0632 -0.0620
 -0.0647 -0.0659 -0.0671 -0.0696 -0.0671 -0.0690 -0.0699 -0.0623 -0.0607 -0.0616 -0.0641 -0.0693 -0.0626 -0.0647 -0.0656 -0.0635 -0.0653 -0.0650 -0.0656 -0.0620 -0.0626
 -0.0671 -0.0662 -0.0677 -0.0665 -0.0674 -0.0653 -0.0711 -0.0613 -0.0516 -0.0592 -0.0647 -0.0656 -0.0632 -0.0644 -0.0638 -0.0616 -0.0650 -0.0629 -0.0656 -0.0601 -0.0616
 -0.0656 -0.0647 -0.0656 -0.0671 -0.0671 -0.0632 -0.0668 -0.0626 -0.0568 -0.0519 -0.0586 -0.0665 -0.0604 -0.0601 -0.0592 -0.0620 -0.0598 -0.0604 -0.0592 -0.0610 -0.0620
 -0.0641 -0.0671 -0.0671 -0.0656 -0.0665 -0.0681 -0.0684 -0.0638 -0.0623 -0.0500 -0.0473 -0.0708 -0.0607 -0.0595 -0.0607 -0.0613 -0.0616 -0.0610 -0.0641 -0.0632 -0.0644
 -0.0641 -0.0684 -0.0674 -0.0671 -0.0684 -0.0702 -0.0696 -0.0650 -0.0623 -0.0552 -0.0436 -0.0647 -0.0644 -0.0595 -0.0632 -0.0641 -0.0653 -0.0616 -0.0635 -0.0653 -0.0632
 -0.0671 -0.0690 -0.0684 -0.0674 -0.0699 -0.0677 -0.0699 -0.0644 -0.0647 -0.0610 -0.0430 -0.0467 -0.0629 -0.0623 -0.0671 -0.0638 -0.0620 -0.0635 -0.0632 -0.0635 -0.0610
 -0.0696 -0.0702 -0.0681 -0.0696 -0.0647 -0.0656 -0.0659 -0.0623 -0.0635 -0.0592 -0.0446 -0.0461 -0.0522 -0.0620 -0.0650 -0.0641 -0.0586 -0.0610 -0.0647 -0.0616 -0.0616
 -0.0668 -0.0644 -0.0650 -0.0677 -0.0668 -0.0632 -0.0656 -0.0616 -0.0620 -0.0543 -0.0531 -0.0491 -0.0418 -0.0586 -0.0613 -0.0626 -0.0589 -0.0623 -0.0674 -0.0592 -0.0613
 -0.0662 -0.0623 -0.0653 -0.0656 -0.0656 -0.0650 -0.0699 -0.0641 -0.0616 -0.0607 -0.0604 -0.0488 -0.0464 -0.0528 -0.0616 -0.0595 -0.0632 -0.0626 -0.0671 -0.0613 -0.0598
 -0.0644 -0.0671 -0.0674 -0.0696 -0.0668 -0.0671 -0.0696 -0.0626 -0.0607 -0.0644 -0.0638 -0.0696 -0.0626 -0.0583 -0.0623 -0.0610 -0.0635 -0.0626 -0.0659 -0.0613 -0.0635
Attachment 4: OMEGA_OM-DAQPRO-5300_06-Apr-17_13.58.21.dlp
Attachment 5: Ta#51.docx
Attachment 6: TS-2017-03-24-16-07.rga
Attachment 7: TS-2017-03-28-11-15.rga
Attachment 8: TS-2017-03-29-13-26.rga
Attachment 9: ITW-TM2-Ta#51-LP-SIS_Test_Stand.docx
  573   Wednesday, March 22, 2017, 09:37 Anders Mjos       Pump down empty chamber

Wednesday, March 22, 2017, 09:3: Roughing

Wednesday, March 22, 2017, 10:05: Turbos started


Friday, March 24, 2017, 11:01: Turbos off. Ion gauge off.

Friday, March 24, 2017, 14:42: Venting.

  572   Friday, March 10, 2017, 15:42 Aaron SchmidtUC#19   41882-441751-2In progressConditioning Heat shield for UC#19

Friday, March 10, 2017, 15:40: Roughing.

Friday, March 10, 2017, 15:58: Turbo pumps started.

Friday, March 10, 2017, 16:19: Ion gauge on.

Friday, March 10, 2017, 16:22: RGA on.


Monday, March 13, 2017, 09:20: Water lines opened. No response on RGA. Vacuum @ 1.99e-07T

Monday, March 13, 2017, 09:38: Power/sources on

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 24.6 3.84
 TBHT 24.4 3.00
 COIL + EE 24.4 4.89
 TGHT  24.6 5.56

Monday, March 13, 2017, 09:42: Auto ramping TGHT to 580A @ 2A per min.

Monday, March 13, 2017, 11:58: Water: 95 PSI on Supply. 10 PSI on Return.

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 26.1 3.82
 TBHT 26.3 3.20
 COIL + EE 24.7 4.95
 TGHT  25.4 5.56

 


Tuesday, March 14, 2017, 08:55: Vacuum @ 3.26e-07T

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 34.0 3.85
 TBHT 25.9 3.11
 COIL + EE 24.9 4.98
 TGHT  26.8 5.57

Tuesday, March 14, 2017, 15:54:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 34.1 3.82
 TBHT 25.2 3.07
 COIL + EE 25.0 4.94
 TGHT  27.1 5.58

Tuesday, March 14, 2017, 15:55: Auto-cooling started @ 2A per min


Tuesday, March 21, 2017, 09:30: Power/Sources off.

Tuesday, March 21, 2017, 14:11: RGA off

Tuesday, March 21, 2017, 14:13: Ion gauge & Turbo pumps off.


by Anders

Wednesday, March 22, 2017, 08:47: Venting

Wednesday, March 22, 2017, 09:3: HS removed

Attachment 1: TS-2017-03-10-16-20.rga
Attachment 2: OMEGA_OM-DAQPRO-5300_22-Mar-17_09.05.23.dlp
  571   Tuesday, February 21, 2017, 10:35 Aaron Schmidt    42218-1141751-6Problems/SolutionsWater leak (E)(G)

Water leak found on water block lines (E) & (G) on FS #3.

Both lines were removed at the water blocks and the coil connection at the heat shield. They ends were blanked off.

Tuesday, February 21, 2017, 10:32: Roughing

Tuesday, February 21, 2017, 10:34: BV1B opened.

Tuesday, February 21, 2017, 10:51: Turbo pumps started.

Tuesday, February 21, 2017, 11:23: Ion gauge & RGA started. Vacuum @ 7.60E-06T.


Wednesday, February 22, 2017, 10:30: The test stand was pressurized with Air (HPA). The loop was completed through the heat shield line FS #5.

Pressurized @ 80 PSI w/ HPA. Monitor. No response on RGA or Vacuum.

Wednesday, February 22, 2017, 10:42: The test stand was pressurized with Helium. The loop was completed through the heat shield line FS #5. The air was purged from the lines using the Helium.

Pressurized @ 30 PSI w/ Helium. Monitor.

Wednesday, February 22, 2017, 11:57: De-pressurize the lines. No response on RGA.

Wednesday, February 22, 2017, 13:47: Pressurize line (G) @ 40 PSI w/ Helium directly.

Wednesday, February 22, 2017, 14:00: No response on RGA or Vacuum. Disconnect.

Wednesday, February 22, 2017, 14:03: Pressurize line (E) @ 38 PSI w/ Helium directly.

Wednesday, February 22, 2017, 14:30: No response on RGA or Vacuum. Disconnect.


Thursday, February 23, 2017, 08:11: RGA, Ion gauge, & Turbo pumps off.

Thursday, February 23, 2017, 10:21: Venting.

Thursday, February 23, 2017, 11:45 Lines (G)(E) reinstalled w/ new seals

Thursday, February 23, 2017, 11:58: Roughing.

Thursday, February 23, 2017, 13:00:  Turbos on.

Thursday, February 23, 2017, 13:05: Ion Gauge on.

Thursday, February 23, 2017, 13:10: RGA on.


Friday, February 24, 2017, 08:15: Waterlines opened on FS #3.

Friday, February 24, 2017, 08:18: RGA froze.

Friday, February 24, 2017, 08:20: Restarted RGA.

Friday, February 24, 2017, 08:48: FS #2, #4, #5 all opened.

Friday, February 24, 2017, 10:20: Vacuum & Leak appear to be stable. Vacuum @ 2.54E-07T

Friday, February 24, 2017, 10:25: Cage re-installed on top of vacuum Chamber

Friday, February 24, 2017, 10:28: Power/sources on

Friday, February 24, 2017, 10:30: Auto ramping TGHT / TBHT to 580 / 200 A @ 4A per min. Heat check.

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 21.4 4.06
 TBHT 22.2 3.28
 COIL + EE 21.2 5.16
 TGHT  21.4 5.82

Friday, February 24, 2017, 10:37: RGA froze (Fatal communication error message).

Friday, February 24, 2017, 10:40: RGA restarted.

Friday, February 24, 2017, 13:30: No major sign of leak detected. Standard response on Vacuum and RGA to heating.

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 32.1 4.06
 TBHT 24.5 3.28
 COIL + EE 23.0 5.17
 TGHT  24.9 5.80

Friday, February 24, 2017, 13:55: Vacuum and water appear leveled off with no indication of a major leak.

Friday, February 24, 2017, 14:00: Auto-cooling started @ 4A per min.


Monday, February 27, 2017, 08:12: Power/sources off. The likely cause for the leak was one of the seals within lines (G)(E). Either one of the O-rings or VCR's. Once the seals were changed, no further leaks were detected.

Wednesday, March 08, 2017, 08:40: RGA timed out. RGA off. No leak detected.


Friday, March 10, 2017, 10:05: Water lines purged.

Friday, March 10, 2017, 10:09: Ion gauge & Turbos off.

Friday, March 10, 2017, 14:24: Venting.

  570   Wednesday, February 15, 2017, 13:42 Aaron Schmidt    42218-1141751-6Problems/SolutionsVacuum Check (Water leak)

*Vacuum from previous test still active, minus turbo pumps. Same target, & heat shield as well.*

Wednesday, February 15, 2017, 13:38: Both Turbo pumps started.

Wednesday, February 15, 2017, 13:43: Ion gauge on. TP1B @ speed 42 KRPM.

Wednesday, February 15, 2017, 13:51: RGA on. Vacuum @4.79E-05T.

Monitor water & vacuum with the RGA.


Thursday, February 16, 2017, 09:05: Main water supply & return shut off to the test stand. Purged. Vacuum @ 7.13E-07T.

Thursday, February 16, 2017, 09:16: Vacuum @ 3.59E-07T. Confirms water leak

Thursday, February 16, 2017, 09:17: RGA stopped.

Thursday, February 16, 2017, 09:20: RGA restarted.

Thursday, February 16, 2017, 09:30: Open main supply & return water supply. Individual valves are closed.

Thursday, February 16, 2017, 09:35: Open supply and return to FS #2. Vacuum @ 3.24E-07T. No response on RGA

Thursday, February 16, 2017, 09:40: Open supply and return to FS #3. Vacuum @ 6.76E-07T. Response on RGA. (Leak detected)

Thursday, February 16, 2017, 09:42: Close main Supply & Return. Purge & close FS #2 & FS #3 . Allow vacuum to stabilize.

Thursday, February 16, 2017, 09:50: Open main supply & return water supply. Open supply and return to FS #3. Vacuum @ 6.76E-07T. Response on RGA. (Leak confirmed)

Thursday, February 16, 2017, 09:53: Close main Supply & Return. Purge & close FS #3 . Allow vacuum to stabilize.

Thursday, February 16, 2017, 09:55: Open main supply & return. All valves are closed. Vacuum @ 3.51E-07T

Thursday, February 16, 2017, 10:00: Open supply and return to FS #4. Vacuum @3.26E-07T. No response on RGA.

Water leak confirmed in FS #3

Thursday, February 16, 2017, 10:05: Close main Supply & Return. Purge & close FS #4 . Allow vacuum to stabilize.

Thursday, February 16, 2017, 10:37: RGA off.

Thursday, February 16, 2017, 10:38: Ion gauge. Turbos off

Thursday, February 16, 2017, 11:58: Venting


Friday, February 17, 2017, 14:10: Roughing.

Friday, February 17, 2017, 14:30: Both Turbo pumps started.

Friday, February 17, 2017, 14:36: Ion gauge on.

Friday, February 17, 2017, 14:44: RGA on. Vacuum @ 2.32E-05T. Note* Waterlines FS #3 currently pressurized with 38 PSI Helium.


Monday, February 20, 2017, 08:26: Vacuum @ 2.60E-07T

Leak is apparent on RGA via Helium. He @ 20 PSI

Monday, February 20, 2017, 09:55: He in line brought up to 40 PSI. Monitor on RGA.

Monday, February 20, 2017, 10:00: No response on RGA. Connectivity gaps?. 

Monday, February 20, 2017, 10:05: RGA restarted. 

Monday, February 20, 2017, 10:39: Top cage removed from test stand. Waterlines purged of Helium. Immediate drop in RGA Helium reading.

Monday, February 20, 2017, 11:23: FS #3 (K) re-routed with return from (F). EE (K) pressurized with He @ 20-30 PSI. No significant response on RGA. Purge He

Monday, February 20, 2017, 11:36: FS #3 (K) returned back to (G). Return connected through (E). Pressurized to 20-30 PSI. No significant response on RGA. Purge He

Monday, February 20, 2017, 11:46: FS #3 (K) routed through to (H). (F) return to return. Pressurized to 20-30 PSI. Left pressurized for one hour

Monday, February 20, 2017, 12:51: No response on RGA. He Purged.

Monday, February 20, 2017, 12:55: Re-pressurize all of FS #3 with He @ 30 PSI.

Monday, February 20, 2017, 13:00: Purge Helium. Switch to water.

Monday, February 20, 2017, 13:12: Water supply/return on. No response on RGA.

Monday, February 20, 2017, 13:22: Slow response noted on RGA. Slow climb on water observed.

Monday, February 20, 2017, 13:30: Slight increase from 2.52E-07T to 3.26E-07T noted on Vacuum. Purge water lines. Reconnect/route lines & Test.

Monday, February 20, 2017, 13:40: FS #3 (K) re-routed with return from (F). EE (K). Open waterlines & observe.

Monday, February 20, 2017, 13:57: No response on RGA or Vacuum. Purge water & Re-route lines.

Monday, February 20, 2017, 14:05: FS #3 (K) returned back to (G). Return connected through (E). Open waterlines & observe.

Monday, February 20, 2017, 14:10: The water leak is apparent on (G) & (E) route. Vacuum climbed from 2.80E-07T to 3.33E-07T. RGA shows increase on water.

Monday, February 20, 2017, 14:14: Purge water lines.

Monday, February 20, 2017, 14:21: FS #3 (K) routed through to (H). (F) return to return. Waterlines opened to rule out (F) & (H) route.

Monday, February 20, 2017, 14:30: No response on RGA. Vacuum Stable. Purge water & Re-connect lines back to standard.

Monday, February 20, 2017, 15:22: Intermittent purging. Flow meter paddles pick up speed with air if purged for too long.


Tuesday, February 21, 2017, 08:34: RGA off, Ion gauge off, Turbos off.

Tuesday, February 21, 2017, 09:32: Venting.

  569   Monday, February 06, 2017, 09:14 Aaron Schmidt      Problems/SolutionsPower outage.

Weekend power outage. All turbos were tripped. Epics white out. Control group notified.

Monday, February 06, 2017, 09:07: Turbo pumps TMS : TP2 & TMS : TP6 restarted.

Monday, February 06, 2017, 09:12: TMS: IG6 ion gauge restarted.

Monday, February 06, 2017, 10:14: Turbo pumps TSG : TP1A & TSG : TP1B restarted.

Monday, February 06, 2017, 10:19: Ion gauge on. TP1B @ speed 42 KRPM.

Monday, February 06, 2017, 10:22: TP1A @ speed 38 KRPM.

ELOG V2.9.2-2455