Message ID: 584     Entry time: Tuesday, May 16, 2017, 14:25
Author: Aaron Schmidt 
Target/No.#:  
Source: HP-FEBIAD-CTL 
Station:  
Module:  
Target Oven W.O#:  
Heat Shield W.O#:  
Status:  
Subject: Tri-Coil CTL-FEBIAD test III 

Coil loose (Remove lid, Tighten and place lid again)

Tuesday, May 16, 2017, 14:24: Roughing.

Tuesday, May 16, 2017, 14:45: Turbo pumps on.


Wednesday, May 17, 2017, 06:53: RGA on. Vacuum @ 7.40e-07T

Wednesday, May 17, 2017, 08:04: Open waterline FS#5. OK. Vacuum @ 6.93e-07T

Wednesday, May 17, 2017, 08:05: Open waterline FS#4. OK.

Wednesday, May 17, 2017, 08:06: Open waterline FS#2. OK.

Wednesday, May 17, 2017, 08:07: Open waterline FS#3. OK.

Wednesday, May 17, 2017, 08:10: Vacuum @ 6.93e-07T. No response on RGA

Wednesday, May 17, 2017, 08:26: RGA Error out. Restart RGA.

Wednesday, May 17, 2017, 08:35: Vacuum ok @ 6.87e-07T. RGA ok.


Sparking issues


Wednesday, May 17, 2017, 13:00:

BIAS / EZL / EE @ 35 / 13 / 1.5 kV .

Coil @ 50 A . Anode @ 200 V

RGA Fatal errors. unable to restart. Reboot in morning.

Wednesday, May 17, 2017, 14:25: Auto ramping TGHT / TBHT to 300 / 150 A @ 2/1 A per min.

Wednesday, May 17, 2017, 15:05: BIAS / EZL / EE @ 30 / 13 / 1.5 kV .


Thursday, May 18, 2017, 08:27: Auto ramping TGHT / TBHT to 400 / 200 A @ 2/1 A per min.

Thursday, May 18, 2017, 08:33: RGA on.

Thursday, May 18, 2017, 08:37: IV4 opened

Thursday, May 18, 2017, 08:42: Optics on/set


Monday, May 22, 2017, 07:55: RGA, Power/Sources off.

Monday, May 22, 2017, 07:59: Turbo pumps, Ion gauge off.

Monday, May 22, 2017, 09:03: Venting

Monday, May 22, 2017, 09:40: 6 block screws tightened.

Attachment 1: CTL_FEBIAD_Test_target_III.docx  1.169 MB  Uploaded Monday, May 22, 2017, 10:44
Attachment 2: TS-2017-05-17-13-00.rga  24 kB  Uploaded Monday, May 22, 2017, 10:44
Attachment 3: TS-2017-05-17-13-30.rga  24 kB  Uploaded Monday, May 22, 2017, 10:44
Attachment 4: TS-2017-05-18-08-30.rga  2.899 MB  Uploaded Monday, May 22, 2017, 10:44
Attachment 5: CTL_FEBIAD_Test_target_II_(Spark_out).docx  470 kB  Uploaded Monday, May 22, 2017, 10:44
Attachment 6: TS-2017-05-17-06-55.rga  63 kB  Uploaded Monday, May 22, 2017, 10:45
Attachment 7: TS-2017-05-17-08-30.rga  49 kB  Uploaded Monday, May 22, 2017, 10:45
Attachment 8: TS-2017-05-17-12-33.rga  34 kB  Uploaded Monday, May 22, 2017, 10:45
ELOG V2.9.2-2455