Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Test-Stand, Page 10 of 53  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Author Target/No.# Source Station Module Target Oven W.O#down Heat Shield W.O# Status Subject
  507   Monday, May 02, 2016, 16:03 Aaron SchmidtSiCLP-SIS  41077-3  EE new insulator Test

Monday, May 02, 2016, 16:01: Roughing.

Monday, May 02, 2016, 16:35: Turbos started -AM

 Monday, May 02, 2016, 16:43: Turbos at speed. Vacuum at 1.6E-5 T - AM


Tuesday, May 03, 2016, 08:15: Opened water  supply for heat shield. Vacuum stable at 2.5E-7 T. No response on RGA.

Tuesday, May 03, 2016, 08:33: Sources on

Tuesday, May 03, 2016, 08:37: Auto ramping TGHT/TBHT to 420A/220A @ 2A/min

Tuesday, May 03, 2016, 08:44: Sources off Except TGHT/TBHT

Tuesday, May 03, 2016, 08:47:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  28.9 3.99
 TBHT  29.6 3.24
 COIL + EE  28.5 5.15
 TGHT  28.7 5.77

 Tuesday, May 03, 2016, 12:42:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.5 4.06
 TBHT  29.6 3.17
 COIL + EE  28.7 5.16
 TGHT  29.8 5.78

Tuesday, May 03, 2016, 15:29;

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.7 4.02
 TBHT  30.4 3.26
 COIL + EE  29.0 5.16
 TGHT 30.0

5.77

 


Wednesday, May 04, 2016, 08:00:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.5 3.99
 TBHT  29.5 3.22
 COIL + EE  28.7 5.16
 TGHT 29.6

5.74

Wednesday, May 04, 2016, 12:53:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.5 4.06
 TBHT  29.6

3.19

 COIL + EE  28.7 5.19
 TGHT 29.6

5.72

Wednesday, May 04, 2016, 14:56: TSHWSW-1: 8 Psi , Gauge below: 106 Psi

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.5 4.02
 TBHT  29.8

3.19

 COIL + EE  28.8 5.21
 TGHT 29.8

5.80

 Wednesday, May 04, 2016, 15:01: Begin auto-cooling @ 2A/min.


Thursday, May 05, 2016, 08:33: TBHT/TGHT off. Ion gauge off. Turbo pumps off.


Friday, May 06, 2016, 08:10: Water lines purged. Power supply off. Venting.

Attachment 1: TS-2016-05-02_EE_insulator_test.rga
  508   Friday, May 06, 2016, 10:18 Aaron SchmidtSiCLP-SIS  41077-3  EE new insulator Test (2) No PE

Friday, May 06, 2016, 10:18: Begin roughing

Venting: VCR on HS not closed

Friday, May 06, 2016, 12:58: Roughing

Friday, May 06, 2016, 13:22: Started turbos

Friday, May 06, 2016, 15:32: Vacuum at 1.2E-5 T


Monday, May 09, 2016, 09:07: Opened water  supply for heat shield. Vacuum stable at 2.78E-7 T.

Monday, May 09, 2016, 09:16:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  28.9 4.06
 TBHT 30.8 3.33
 COIL + EE  28.5 5.24
 TGHT  28.7 5.80

Monday, May 09, 2016, 09:35: Auto ramping TGHT/TBHT to 420A/220A @ 2A/min.

Monday, May 09, 2016, 13:26:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.7 4.06
 TBHT 31.8

3.40

 COIL + EE  28.8 5.19
 TGHT  30.0 5.82

 


Tuesday, May 10, 2016, 08:18:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.7 4.06
 TBHT 30.3

3.27

 COIL + EE  28.8 5.19
 TGHT  29.8 5.77

Tuesday, May 10, 2016, 12:36:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.5 4.06
 TBHT 29.9

3.20

 COIL + EE  28.8 5.18
 TGHT  29.8 5.82

Tuesday, May 10, 2016, 15:21:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.7 4.02
 TBHT 29.4

3.15

 COIL + EE  28.8 5.16
 TGHT  30.0 5.73

 


Wednesday, May 11, 2016, 08:45:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.5 4.02
 TBHT 29.3

3.16

 COIL + EE  28.8 5.13
 TGHT  30.0 5.77

Wednesday, May 11, 2016, 14:13:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 33.8 4.06
 TBHT 29.6

3.16

 COIL + EE  29.0 5.19
 TGHT  30.0 5.78

 

Wednesday, May 11, 2016, 17:39: Ramping down TGHT/TBHT -AM


Thursday, May 12, 2016, 08:04: Ion gauge off. Turbo pumps off.

Thursday, May 12, 2016, 11:08: Water lines off/purged. Venting.

Thursday, May 12, 2016, 11:32: Source off, lock on.

  509   Thursday, May 12, 2016, 13:32 Aaron SchmidtSiCLP-SIS  41077-3  EE new insulator Test, No PE , Dirty EE.

Thursday, May 12, 2016, 13:00: Begin Roughing.

Thursday, May 12, 2016, 13:40: Turbo Pumps started

Thursday, May 12, 2016, 13:46: Ion gauge switched on.


Friday, May 13, 2016, 08:33: Opened water  supply for heat shield. Vacuum stable at 3.70E-7 T.

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  28.9 4.06
 TBHT 29.0 3.20
 COIL + EE  28.5 5.24
 TGHT  28.5 5.72

Friday, May 13, 2016, 10:01: Auto ramping TGHT/TBHT to 420A/220A @ 2A/min.

Friday, May 13, 2016, 13:55

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  33.7 3.95
 TBHT 29.8 3.16
 COIL + EE  29.0 5.17
 TGHT  30.0 5.72

 


Monday, May 16, 2016, 11:29:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  33.7 4.06
 TBHT 29.4 3.18
 COIL + EE  28.7 5.18
 TGHT  29.8 5.77

Monday, May 16, 2016, 15:59:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  33.8 4.02
 TBHT 29.9 3.20
 COIL + EE  29.1 5.21
 TGHT  30.1 5.77

Note: RGA misread.


Tuesday, May 17, 2016, 15:15:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  33.8 4.02
 TBHT 30.6 3.29
 COIL + EE  29.0 5.16
 TGHT  30.1 5.74

Note: RGA Misread.


Wednesday, May 18, 2016, 14:30: IV4 open. FC0 open

Wednesday, May 18, 2016, 14:58: FC0 closed.

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  33.8 4.02
 TBHT 29.3 3.15
 COIL + EE  29.0 5.14
 TGHT  30.0 5.72

 


Thursday, May 19, 2016, 16:26:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  33.8 4.06
 TBHT 29.3 3.15
 COIL + EE  28.8 5.17
 TGHT  30.0 5.77

 


Friday, May 20, 2016, 14:59:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  33.8 4.02
 TBHT 29.6 3.20
 COIL + EE  28.8 5.14
 TGHT  30.0 5.79

 


Tuesday, May 24, 2016, 15:31:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  33.8 4.02
 TBHT 29.9 3.18
 COIL + EE  29.0 5.15
 TGHT  30.1 5.72

 


Thursday, May 26, 2016, 15:18:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  34.0 4.02
 TBHT 30.6 3.28
 COIL + EE  29.0 5.14
 TGHT  30.0 5.75

 


Friday, May 27, 2016, 15:27: IV4 Closed

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  33.8 4.02
 TBHT 32.2 3.42
 COIL + EE  28.7 5.22
 TGHT  29.7 5.77

 


Monday, May 30, 2016, 08:35:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  33.8 4.05
 TBHT 29.9 3.25
 COIL + EE  28.7 5.18
 TGHT  29.7 5.78

Monday, May 30, 2016, 08:54: Auto ramp down TGHT/TBHT @ 2A/1A per min to 0A.


Tuesday, May 31, 2016, 08:25: Ion gauge off. Turbo pumps off.


Wednesday, June 01, 2016, 09:10: Venting

Wednesday, June 01, 2016, 9:45: Water lines purged, power off.

  351   Wednesday, December 18, 2013, 12:04 Anders Mjos    40282-539230-1DoneHeating Test

 Wednesday, December 18, 2013, 12:04: Turbos stopped

Wednesday, December 18, 2013, 13:19: Venting

Ta-tube installed. All bolts torqued to 130 in lbs

Thermocouples installed.

CH1 1/2: welded outside tube centre - type C
CH2 4/5: inside probe left side - type C
CH3 6/7: inside probe right side - type C
CH4 8/9: welded on leg - type K

Wednesday, December 18, 2013, 14:41: Roughing

Initial temperatures
CH1  28.1
CH2  30.7
CH3  31.3
CH4  31.0

Wednesday, December 18, 2013, 15:50: Starting turbos.

Wednesday, December 18, 2013, 15:58: Turbos at speed.

Wednesday, December 18, 2013, 16:00: Vacuum at 9.3E-6 Torr


Thursday, December 19, 2013, 09:35  : Opened water for HS. Vacuum stable at 2.5E-7 Torr. Flow ~ 3.9 l/min

temperatures
CH1  26.3
CH2  Un
CH3  28.7
CH4  30.5

Thursday, December 19, 2013, 16:50: Ta-tube at 500A ~ 1380 deg C.

temperatures
CH1  33.6
CH2  1319.3
CH3  1443.4
CH4  20.1


Heated to 580A

Friday, December 20, 2013, 10:48: Started cool down at 2A/min.

Friday, December 20, 2013, 15:46: Switched off TGHT.

  354   Tuesday, January 14, 2014, 08:58 Anders Mjos    40282-539230-1DoneHeating Test

Tuesday, January 14, 2014, 08:57: Stopping turbos. Vacuum at 1.2E-7 T

Tuesday, January 14, 2014, 13:32: Venting 

Ta-tube installed. All bolts torqued to 130 in lbs

Thermocouples installed. CH2/3 left/right swapped with respect to previous test.

CH1 1/2: welded outside tube centre - type C
CH2 4/5: inside probe right side - type C
CH3 6/7: inside probe left side - type C
CH4 8/9: welded on leg - type K

Tuesday, January 14, 2014, 15:10: Roughing 
Tuesday, January 14, 2014, 15:33: Starting turbos.
Tuesday, January 14, 2014, 15:42: Turbos at speed
Tuesday, January 14, 2014, 15:43: Vacuum at  2.3E-5 T


Wednesday, January 15, 2014, 10:32: Opened water. Vacuum stable at 2.9E-7 T.


Monday, January 20, 2014

Started heating the Target-tube. 

Pressure increase observed on water supply around 10. Supply ~100psi, return ~7 psi


Tuesday, January 21, 2014

Continue heating from 250 A

Tuesday, January 21, 2014, 15:47: TGHT at 580 A, 7.23 V


Wednesday, January 22, 2014

Target-tube cooled down over night. Will went to investigate TC connections.

Wednesday, January 22, 2014, 08:38 : Turbos stopped. Vacuum at 1.3E-7 T

  394   Friday, July 18, 2014, 11:30 Anders MjosUC#10LP-SISITETM440282-540316-1DoneUC#10 Heat Shield Conditioning

Friday, July 18, 2014, 11:30: Roughing

Friday, July 18, 2014, 11:51: Starting turbos

Friday, July 18, 2014, 11:59: Turbos at speed.

Friday, July 18, 2014, 12:01: Vacuum at 1.4E-5 T


Monday, July 21, 2014, 08:51: Opened water for HS circuit. Small vacuum "bump" recovered to 1.5E-7 T

Monday, July 21, 2014, 09:17: Starget TGHT autoramping to 580A @ 2 A/min

Monday, July 21, 2014, 14:05: TGHT @ 580A 7.47V.


Tuesday, July 22, 2014, 10:41: Data logger installed

Device
 
Temp
[C]
Flow
[lpm]
HS + MSP 37.6 3.7
TBHT 28.5 6.1
COIL + EE 28.7 4.8
TGHT 31.0 5.4

 Tuesday, July 22, 2014, 13:41: BIAS / EZL / EE to 30 / 14 /2 kV. EE:RDCUR 695 uA

Tuesday, July 22, 2014, 14:23: Starting cool down of TGHT 2A/min. Vacuum at 2.7E-7 T 


Wednesday, July 23, 2014, 09:05: BIAS / EZL / EE off. Turbos off. Vacuum at 1.3E-7 T.

Device Temp
[C]
Flow
[lpm]
HS + MSP 28.5 3.7
TBHT 28.3 6.1
COIL + EE 29.2 5.2
TGHT 28.4 5.7

 Wednesday, July 23, 2014, 14:05: Purged HS water line.

Wednesday, July 23, 2014, 14:07 : Venting

Wednesday, July 23, 2014, 14:33: Heat Shield removed

  403   Monday, September 08, 2014, 16:23 Anders MjosUC#11  TM440282-5 DoneUC#11 Heat Shield Conditioning

T/C installed

CH 1: Attached to TGHT outside middle
CH 2: Through HS outside TGHT right
CH 3: Through HS inside TGHT  right
CH 4: Attached to HS on left gripper. Does not read temp

Monday, September 08, 2014, 16:22: Roughing

Monday, September 08, 2014, 16:43: Started turbos

Monday, September 08, 2014, 16:51: Turbos at speed

Monday, September 08, 2014, 16:53: Vacuum at 2.7E-5 T


Tuesday, September 09, 2014, 08:20 : Opened HS water supply. Vacuum stable at 3.7E-7 T

Tuesday, September 09, 2014, 08:21: Starting auto ramping. TGHT to 580 A at 2A/min

Tuesday, September 09, 2014, 08:50 :

Device Flow
[lpm]
Temp
[C]
HS + MSP 3.8 26.7
TBHT 6.5 26.2
COIL + EE 5.3 26.9
TGHT 5.8 26.3
SUPPLY   27.0

 


Wednesday, September 24, 2014, 11:30: T/C attached to tube does no longer read a correct temperature. Cooling down.


Thursday, September 25, 2014, 08:50: Turbos stopped.

Thursday, September 25, 2014, 11:07: Venting

Thursday, September 25, 2014, 14:00: Heat shield removed

Attachment 1: Thermocouples.xlsx
  404   Thursday, September 25, 2014, 15:44 Anders MjosThO#1 ITWTM140282-5 DoneThO#1 Heat Shield Conditioning

Thursday, September 25, 2014, 15:44: Roughing

Thursday, September 25, 2014, 16:06: Starting turbos

Thursday, September 25, 2014, 16:14: Turbos at speed.

Thursday, September 25, 2014, 16:28: Vacuum at 1.9E-5 T


Vacuum was coming down slowly yesterday. Vented this morning to clean o-ring on door.

Friday, September 26, 2014, 08:40: Roughing

Friday, September 26, 2014, 09:02: Starting turbos

Friday, September 26, 2014, 09:10: Turbos at speed

Friday, September 26, 2014, 09:12: Vacuum at 9.7E-6 T


Monday, September 29, 2014, 08:40: Water opened for HS circuit. Vacuum stable at 1.8E-7 T

Monday, September 29, 2014, 13:51: Opened and closed IV4


Wednesday, October 01, 2014, 13:13 : Target cooled down.


Monday, October 06, 2014, 09:10: Turbos stopped. Vacuum at 1.3E-7 T

Monday, October 06, 2014, 10:49: Venting


Tuesday, October 07, 2014, 09:31: Heat Shield removed

  397   Friday, August 08, 2014, 12:45 Anders MjosZrC#6LP-SISITWTM140282-339230-5DoneCondictioning ZrC#6

Friday, August 08, 2014, 12:44: Stopped turbos

Friday, August 08, 2014, 14:42: Venting 

Target assembly inserted

Friday, August 08, 2014, 15:08: Roughing

Friday, August 08, 2014, 15:29: Turbos started

Friday, August 08, 2014, 15:37: Turbos at speed

Friday, August 08, 2014, 15:39: Vacuum at 1.4E-5 T


Monday, August 11, 2014, 08:58: Opened HS cooling water. Vacuum stable at 1.6E-7 T


Tuesday, August 12, 2014, 10:31: IV4 Opened

Tuesday, August 12, 2014, 10:35: EZL / EE / BIAS to 14 / -1.5 / 30 kV

Tuesday, August 12, 2014, 10:39: Starting target heat to 300 A / 96 (115) A


Wednesday, August 13, 2014, 08:03 : Continue heating to 580 A / 190 (228) A

Wednesday, August 13, 2014, 08:24: Aborting target heating. Cu-LCW pressure and flow is reduced due to a problem with a pump.

Device Flow
[lpm]

Temp
[C]

HS + MSP 1.9 27.7
TBHT 4.1 23.9
COIL + EE 3.5 25.1
TGHT 3.7 25.6
SUPPLY   24.4

Supply pressure ~ 52 psi
Return pressure ~ 11 psi

 Wednesday, August 13, 2014, 08:31: Starting cool down as flow rate on HS + MSP is low. A low flow trip of the TGHT should be avoided.

Wednesday, August 13, 2014, 11:54 : Curtis Ballard contacted me and asked if they could valve off the Cu-LCW circuit to the Test Stand. Heaters had been previously brought down. Bias off and power supplies are switched off. IV4 closed.

Wednesday, August 13, 2014, 12:00: Cooling water syupply valved off to Test Stand.


 

Flow rates are back to normal since yesterday evening

Device Flow
[lpm]
Temp
[C]
HS + MSP 3.1 27.8
TBHT 5.9 27.4
COIL + EE 5.0 28.3
TGHT 5.4 27.6
SUPPLY   28.1

Thursday, August 14, 2014, 08:00: Conditioning on hold due to FC0 problem


Wednesday, August 20, 2014, 07:50: Conditioning  continues. Auto-ramping to 400 / 150 ( 180) A @ 4/2 A/min

Wednesday, August 20, 2014, 09:35 : Continue heating to 580 / 165 (200) A @ 2/1 A/min

Wednesday, August 20, 2014, 09:50 

 

Device Flow
[lpm]
Temp
[C]
HS + MSP 3.6 32.9
TBHT 6.5 28.5
COIL + EE 5.4 29.2
TGHT 5.8 29.7
SUPPLY   28.8

 Wednesday, August 20, 2014, 15:15: Power lost to TBHT, TGHT and EE during nominal operation (580/ 183 (220) A). Fault report submitted.


PLC cabinet work finished. Resuming conditioning.

Tuesday, August 26, 2014, 16:35:EZL / EE / BIAS to 14 / -1.5 / 30 kV

Tuesday, August 26, 2014, 16:35: Starting target heat to 50 A / 25 A


Wednesday, August 27, 2014:  

Continued conditioning. Heating to 580 /190 (228) A


Thursday, August 28, 2014, 08:34 

Device Flow
[lpm]
Temp
[C]
HS + MSP 3.5 38.0
TBHT 6.4 28.0
COIL + EE 5.5 29.8
TGHT 5.8 30.3
SUPPLY   28.2

 


Friday, August 29, 2014, 10:30: EE conditioned for ~20 min @ 2kV.

Friday, August 29, 2014, 10:32 : Starting cool down at 4/2 A/min

Friday, August 29, 2014, 11:55: Closed IV4

Friday, August 29, 2014, 11:56: BIAS, EE and EZL to 0

Friday, August 29, 2014, 13:10: Stopped turbos.

Friday, August 29, 2014, 14:06: Venting

Friday, August 29, 2014, 14:51: Target removed

  390   Thursday, June 26, 2014, 16:32 Anders MjosTa#43LP-SISITWTM140282-239230-6In progressConditioning Ta#43

Thursday, June 26, 2014, 16:31: Roughing.

Thursday, June 26, 2014, 16:51: Starting turbos. 

Thursday, June 26, 2014, 16:59: Turbos at speed.

Thursday, June 26, 2014, 17:01: Vacuum at 1.2E-5 T


Friday, June 27, 2014, 08:39: Opened HS cooling line. Vacuum stable at 1.9E-7 T


Wednesday, July 02, 2014, 10:24: Vacuum at 1.3E-7 T

Wednesday, July 02, 2014, 10:31: BIAS / EE / EZL to 30 / 1.5 / 14 kV

Wednesday, July 02, 2014, 10:32: Opened TPS:IV4

Wednesday, July 02, 2014, 10:36: Started heating TGHT / TBHT to 400 A / 155 A

Wednesday, July 02, 2014, 14:00: Heating finished for today.


Thursday, July 03, 2014, 08:09 : Resuming heating TGHT / TBHT to 580 A / 200 A. Vacuum at 2.1E-7 T

Thursday, July 03, 2014, 09:17: TGHT voltage limiting. Stopped and restarted heating. 

Thursday, July 03, 2014, 12:51 : Heating TBHT to 230 A

Thursday, July 03, 2014, 13:18: TBHT at 227 A (local readback). Started mass scan.

Thursday, July 03, 2014, 15:39: Lowering TBHT to 218 A (local).


Friday, July 04, 2014, 11:00: Heated to 230 A.

Friday, July 04, 2014, 15:40: Q1/Q6 found off. 

Friday, July 04, 2014, 15:42 : Starting cool down.


Monday, July 07, 2014, 09:24 : Closed TPS:IV4

Monday, July 07, 2014, 09:24: EE conditioning to -2kV 

Monday, July 07, 2014, 10:02: BIAS off. Turbos off. 


Tuesday, July 08, 2014, 08:13: Venting

Attachment 1: Ta#43_Conditioning.docx
  364   Monday, March 17, 2014, 19:10 Anders MjosTa#42LP-SISITWTM440282-139956-1 / 39956-9 (base / lid)In progressConditioning

NOTE:

TBHT Power Supply is 600A. EPICS thinks it is 500. Multiply current setting with 1.2 for actual current to the tube.

Time stamp on OM-DAQPRO-5300 is on hour behind (daylight savings).

 


All bolts torqued to 130 in lbs. TGHT and TBHT bolts tightened and loosened 3x.

Monday, March 17, 2014, 19:10: Roughing

Monday, March 17, 2014, 19:30: Turbos started

 Monday, March 17, 2014, 19:38: Turbos at speed. 

Monday, March 17, 2014, 19:40: Vacuum at 1.3E-5 T


BY R.M.

Tuesday, March 18, 2014, 10:10: Vacuum 2.87e-07 T

Tuesday, March 18, 2014, 10:12: Heatshield Water Circuit turned on

Tuesday, March 18, 2014, 10:25: Vacuum 2.85e-07 T

By AM

Tuesday, March 18, 2014, 16:06:

Conditioned high voltage BIAS to 30kV. BIAS:RDCUR 37 uA.

Started heater auto-ramping. TBHT to 50A at 1A/min. TGHT to 100A at 2 A/min.

Vacuum at 2.7E-7 T

Tuesday, March 18, 2014, 17:06: TBHT and TGHT reached 50A and 100A respectively. Local readback on TBHT is 58A (as expected - see note above). Vacuum is gradually coming down.


Operation stable over night. TSG:CBC needed to be restarted. Switched off over night.

Wednesday, March 19, 2014, 08:21: Continue heating to 85A / 250 A TBHT/TGHT.

Wednesday, March 19, 2014, 09:12

Water temperatures 27 - 28 deg C, and flow Rates
4.0 l/m HS+MSP
6.4 l/m TBHT
5.1 l/m COIL+EE
5.6 l/m TGHT

Wednesday, March 19, 2014, 09:57: Continue heating to 170 A / 500 A, TBHT/TGHT

Wednesday, March 19, 2014, 09:58: Opened IV4

Wednesday, March 19, 2014, 09:58: Restarted Q1.

Wednesday, March 19, 2014, 10:11: Switched FC0 bias to negative

Wednesday, March 19, 2014, 10:30: Q1 restarted. Possible spark. Small vacuum response on IG1

Wednesday, March 19, 2014, 10:49: Some sparking

Wednesday, March 19, 2014, 12:43: Continue heating to 190A / 580 A TBHT/TGHT.

Wednesday, March 19, 2014, 13:00: TBHT voltage limited. Increased limit to 2.3V

Water temperatures and flow rates
35 C 4.0 l/m HS+MSP
28 C 6.4 l/m TBHT
28 C 5.1 l/m COIL+EE
30 C 5.6 l/m TGHT

Wednesday, March 19, 2014, 13:32: Local read back on PS: 223A / 580A TBHT/TGHT

Water temperatures and flow rates
37 C 4.0 l/m HS+MSP
28 C 6.4 l/m TBHT
29 C 5.1 l/m COIL+EE
31 C 5.6 l/m TGHT

Wednesday, March 19, 2014, 14:30: Measured ~2E-7 A 23Na on FC6 and 2E-7 A on FC0. Vacuum on IG1 4.2E-8 T

Wednesday, March 19, 2014, 14:58: TBHT was voltage limiting. Increased voltage limit to 2.4 V

Target will condition over night.


Thursday, March 20, 2014, 10:07: Measured ~1.4E-8 A 23Na on FC6 and 2E-7 A on FC0. Vacuum on IG1 8.3E-7 T

Water temperatures and flow rates
35 C 4.0 l/m HS+MSP
27 C 6.4 l/m TBHT
27 C 5.1 l/m COIL+EE
29C 5.6 l/m TGHT

Thursday, March 20, 2014, 10:13: Starting mass scan 200 - 0

Local current  on PS (TBHT/TGHT): 227 A / 580 A

At about 10:15 to 10:20 the TGHT:RDVOL dropped from 7.2 - 7.1 V.

Thursday, March 20, 2014, 11:05: Mass scan finished.

Water temperatures and flow rates
36 C 4.0 l/m HS+MSP
28 C 6.4 l/m TBHT
29 C 5.1 l/m COIL+EE
30 C 5.6 l/m TGHT

Thursday, March 20, 2014, 13:20

Water temperatures and flow rates
34.8 C 4.0 l/m HS+MSP
26.1 C 6.4 l/m TBHT
26.8 C 5.1 l/m COIL+EE
28.4 C 5.6 l/m TGHT

Thursday, March 20, 2014, 13:24: Conditioning EE to -2kV

Thursday, March 20, 2014, 13:26: EE at -2kV and 694 uA

Thursday, March 20, 2014, 13:36: Lowering EE back to -1.4kV

Thursday, March 20, 2014, 13:38: Starting the cool down of the target at 2 A/min

Thursday, March 20, 2014, 15:08: Closed IV4


Friday, March 21, 2014, 08:32: Lowered BIAS, EE and EZL to 0. TGHT and TBHT off.

Friday, March 21, 2014, 08:33: Stopped turbos. Vacuum at 1.3E-7 T

Friday, March 21, 2014, 13:10: Venting

Attachment 1: Ta#42_Test_Stand.docx
Attachment 2: OMEGA_OM-DAQPRO-5300_21-Mar-14_13.56.35.dlp
  510   Wednesday, June 01, 2016, 10:02 Aaron SchmidtUC#16LP-IG-LISITETM439814-V2-1  Conditioning Heat shield for UC#16

Wednesday, June 01, 2016, 10:02: Begin roughing.

Wednesday, June 01, 2016, 10:44: Turbo pumps started.

Wednesday, June 01, 2016, 10:47: Ion Gauge IG1 ON.

Wednesday, June 01, 2016, 10:50; Turbos at speed. Vacuum at 1.24-5T.


Thursday, June 02, 2016, 08:54: Sources and power supply on. RGA on. Open water. Vacuum stable at 2.1E-07T. Heat shield water flow at 4.0 lpm.

Thursday, June 02, 2016, 09:05: Auto ramping TGHT/TBHT @ 2A min to 580A/250A

Thursday, June 02, 2016, 09:10: BIAS/EZL/EE to 30/13/1.5kV. IV4 opened

Thursday, June 02, 2016, 11:54: Stopped auto ramping for lunch break. - AM

Thursday, June 02, 2016, 13:01 : Auto ramping resumed. -AM

Thursday, June 02, 2016, 15:03: TGHT/TBHT @ 580A/250A

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP  36.1 3.99
 TBHT 27.2 3.14
 COIL + EE  27.1 5.18
 TGHT  29.2 5.78

 

Thursday, June 02, 2016, 20:43: ramping down TGHT/TBHT at 2 / 1 A/min - AM


Friday, June 03, 2016, 08:06: Source off. Turbo pumps off. Ion gauge off. IV4 closed.

Friday, June 03, 2016, 08:21: Supply water pressure: 103 PSI. Return pressure: 10 PSI.

Friday, June 03, 2016, 09:27: Venting.

Attachment 1: OMEGA_OM-DAQPRO-5300_03-Jun-16_08.14.47.dlp
Attachment 2: TS-2016-06-02_UC#16.rga
Attachment 3: TS-2016-06-02-13-46_UC#16.rga
Attachment 4: UC#16.docx
  537   Friday, September 02, 2016, 15:47 Aaron SchmidtSiC#34LP-IG-LISITETM439814-V2-141751-9 Conditioning SiC# 34

Friday, September 02, 2016, 15:47: Roughing.

Friday, September 02, 2016, 16:18: Turbos started -AM

Friday, September 02, 2016, 16:28: Turbos at speed. Vacuum at 2.0E-5 T.


Tuesday, September 06, 2016, 08:13: RGA on.

Tuesday, September 06, 2016, 08:15: Water lines opened. No response on RGA. Vacuum stable @ 1.62E-7T

Tuesday, September 06, 2016, 08:19: Power/sources on.

Tuesday, September 06, 2016, 08:30: BIAS / EZL / EE @ 30 / 13 / 1.5 kV .

Tuesday, September 06, 2016, 08:34: IV4 open. Auto ramping TGHT / TBHT to 580 / 250 A @ 2A per min.

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 28.4 3.78
 TBHT  28.3 2.96
 COIL + EE 28.0 4.89
 TGHT  29.6 5.50

 Tuesday, September 06, 2016, 13:56: Auto ramping TBHT to 270A @ 2A per min

Tuesday, September 06, 2016, 14:05: Turbo pump TP1A found off. Restarted.

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 38.4 0.07
 TBHT  28.5 2.98
 COIL + EE 28.0 4.92
 TGHT  30.0 5.54

 Tuesday, September 06, 2016, 20:49: Ramping down TGHT / TBHT at 2 / 1 A/min


Wednesday, September 07, 2016, 08:46: Sources off. RGA error out. RGA off

Wednesday, September 07, 2016, 08:53: IV4 closed. Ion gauge off.

Wednesday, September 07, 2016, 08:54: Turbo pumps off.

Wednesday, September 07, 2016, 09:06: Power off. Water lines purged.

Wednesday, September 07, 2016, 09:54: Venting.

Attachment 1: ER-580-270-m40.txt
value (Voltage offset       0.0000)
     75.0000
      0.6333
     75.0000
  29978.0220
31
31
./emit.dat
 -0.1025 -0.1068 -0.1050 -0.1047 -0.0986 -0.0983 -0.1068 -0.1096 -0.1053 -0.0995 -0.1004 -0.1068 -0.1025 -0.1056 -0.1001 -0.1044 -0.1056 -0.0977 -0.1019 -0.0998 -0.1059 -0.0909 -0.0912 -0.1102 -0.1083 -0.0842 -0.0925 -0.1135 -0.1157 -0.1193 -0.1218
 -0.0970 -0.0989 -0.1028 -0.1044 -0.1010 -0.1004 -0.1062 -0.1056 -0.0998 -0.1013 -0.1010 -0.1031 -0.0995 -0.0967 -0.1031 -0.1001 -0.1001 -0.0964 -0.1016 -0.1050 -0.1108 -0.1044 -0.0955 -0.0830 -0.1065 -0.0821 -0.0873 -0.0934 -0.1172 -0.1193 -0.1175
 -0.1038 -0.1016 -0.1038 -0.1019 -0.0986 -0.1074 -0.1123 -0.1025 -0.1047 -0.0970 -0.1035 -0.1053 -0.1083 -0.1004 -0.1059 -0.1062 -0.1056 -0.0949 -0.0873 -0.0885 -0.1035 -0.1004 -0.1074 -0.0977 -0.0858 -0.0989 -0.0909 -0.0906 -0.0992 -0.1050 -0.1193
 -0.0992 -0.1004 -0.1035 -0.1050 -0.1050 -0.0986 -0.1062 -0.1013 -0.0989 -0.0995 -0.0986 -0.1004 -0.1031 -0.1050 -0.0964 -0.1013 -0.0967 -0.1096 -0.1068 -0.1035 -0.1062 -0.0961 -0.1080 -0.1096 -0.0903 -0.1007 -0.0800 -0.0912 -0.0784 -0.0909 -0.1163
 -0.1007 -0.0964 -0.0952 -0.0961 -0.1053 -0.1056 -0.1114 -0.1050 -0.0980 -0.1093 -0.1047 -0.1031 -0.1074 -0.0955 -0.1028 -0.1028 -0.1007 -0.1041 -0.1035 -0.0955 -0.1093 -0.1151 -0.1001 -0.1025 -0.1141 -0.1144 -0.0873 -0.0818 -0.1025 -0.1096 -0.1147
 -0.1035 -0.1059 -0.1059 -0.0989 -0.0955 -0.0992 -0.1117 -0.1071 -0.1059 -0.0946 -0.1056 -0.1007 -0.1108 -0.1080 -0.1001 -0.1065 -0.1065 -0.1028 -0.1059 -0.0925 -0.1038 -0.0873 -0.0864 -0.1031 -0.1062 -0.1141 -0.0970 -0.0867 -0.1093 -0.1239 -0.1196
 -0.0952 -0.0967 -0.1028 -0.0998 -0.1031 -0.1019 -0.1086 -0.0992 -0.1010 -0.1004 -0.1059 -0.1013 -0.1035 -0.0967 -0.0998 -0.0949 -0.0961 -0.1022 -0.1065 -0.0989 -0.0961 -0.1099 -0.1074 -0.0900 -0.1035 -0.1178 -0.0885 -0.0848 -0.1144 -0.1059 -0.1105
 -0.1044 -0.1016 -0.1025 -0.1019 -0.1010 -0.1028 -0.1138 -0.1071 -0.1053 -0.1056 -0.1056 -0.1068 -0.1120 -0.1038 -0.1035 -0.1035 -0.1004 -0.1074 -0.0949 -0.0928 -0.1071 -0.0894 -0.1080 -0.1144 -0.0894 -0.1031 -0.0946 -0.0885 -0.0970 -0.0967 -0.1120
 -0.1004 -0.1004 -0.1056 -0.1050 -0.0955 -0.0958 -0.1050 -0.0992 -0.1001 -0.0958 -0.0974 -0.0958 -0.1035 -0.0995 -0.0983 -0.0961 -0.0995 -0.1144 -0.0952 -0.1050 -0.1099 -0.1038 -0.1025 -0.1047 -0.1093 -0.0842 -0.0900 -0.0900 -0.0781 -0.1038 -0.1038
 -0.0986 -0.0961 -0.0964 -0.0989 -0.1035 -0.1059 -0.1123 -0.1035 -0.1004 -0.1044 -0.1089 -0.1019 -0.1071 -0.0964 -0.1077 -0.0986 -0.1004 -0.1056 -0.0970 -0.0986 -0.0946 -0.1099 -0.0934 -0.0879 -0.1157 -0.0992 -0.0952 -0.0848 -0.1047 -0.1120 -0.0961
 -0.1035 -0.1050 -0.1062 -0.1007 -0.0980 -0.1004 -0.1108 -0.1074 -0.1080 -0.1019 -0.1062 -0.1016 -0.1083 -0.1050 -0.1050 -0.1010 -0.1047 -0.1031 -0.0974 -0.0931 -0.1050 -0.0943 -0.0909 -0.1062 -0.1059 -0.1093 -0.0995 -0.0919 -0.1138 -0.1251 -0.0992
 -0.0983 -0.0983 -0.1038 -0.1044 -0.1016 -0.1028 -0.1077 -0.1013 -0.1013 -0.1044 -0.1050 -0.1007 -0.1038 -0.0952 -0.1025 -0.0949 -0.0983 -0.1083 -0.0928 -0.1022 -0.0986 -0.1099 -0.1105 -0.1059 -0.1059 -0.1126 -0.0992 -0.0858 -0.1062 -0.1193 -0.0873
 -0.1035 -0.1007 -0.1041 -0.0980 -0.1019 -0.1047 -0.1138 -0.1053 -0.1062 -0.1050 -0.1065 -0.1050 -0.1083 -0.0986 -0.0998 -0.1025 -0.0998 -0.0955 -0.0912 -0.1035 -0.0995 -0.0906 -0.1096 -0.1068 -0.0943 -0.1215 -0.1038 -0.0854 -0.0885 -0.1071 -0.0897
 -0.0977 -0.1004 -0.1071 -0.1038 -0.0983 -0.0983 -0.1062 -0.1022 -0.1022 -0.0967 -0.0980 -0.0980 -0.1031 -0.1038 -0.0934 -0.0940 -0.1025 -0.1154 -0.0980 -0.1086 -0.0974 -0.1093 -0.1050 -0.0903 -0.0830 -0.1126 -0.0943 -0.0897 -0.0955 -0.0903 -0.0900
 -0.0986 -0.0964 -0.0986 -0.0983 -0.1035 -0.1074 -0.1114 -0.1035 -0.1096 -0.1056 -0.1086 -0.1016 -0.1047 -0.0974 -0.1019 -0.0992 -0.1019 -0.1044 -0.0949 -0.1096 -0.0891 -0.0961 -0.1031 -0.0897 -0.0894 -0.0970 -0.0882 -0.0815 -0.1062 -0.0964 -0.0830
 -0.1038 -0.1038 -0.1071 -0.1016 -0.0992 -0.1019 -0.1129 -0.1074 -0.1007 -0.1007 -0.1074 -0.1025 -0.1093 -0.1041 -0.1004 -0.1041 -0.1089 -0.0488 -0.0998 -0.1077 -0.0964 -0.1071 -0.0879 -0.1138 -0.0970 -0.0900 -0.0906 -0.0879 -0.1279 -0.1163 -0.0946
 -0.0992 -0.0977 -0.1065 -0.1056 -0.1038 -0.1041 -0.1083 -0.1044 -0.1053 -0.1028 -0.1050 -0.1007 -0.1035 -0.1007 -0.0967 -0.0995 -0.1035 -0.0967 -0.1062 -0.1093 -0.0928 -0.0931 -0.1065 -0.1038 -0.1093 -0.1035 -0.0827 -0.0845 -0.1031 -0.1117 -0.0922
 -0.1016 -0.0998 -0.1010 -0.0998 -0.1019 -0.1053 -0.1135 -0.1068 -0.1019 -0.1022 -0.1086 -0.1038 -0.1071 -0.1013 -0.1050 -0.1068 -0.0970 -0.0989 -0.1007 -0.0986 -0.0958 -0.1068 -0.1083 -0.0912 -0.1154 -0.1114 -0.0867 -0.0867 -0.1205 -0.1199 -0.1102
 -0.0986 -0.1016 -0.1056 -0.1041 -0.0970 -0.0986 -0.1031 -0.1019 -0.0974 -0.0955 -0.0998 -0.0943 -0.1056 -0.1022 -0.1022 -0.1028 -0.1074 -0.1212 -0.1074 -0.1089 -0.1038 -0.1071 -0.1038 -0.1035 -0.1062 -0.1083 -0.0845 -0.1001 -0.0873 -0.1221 -0.0961
 -0.0983 -0.0967 -0.0980 -0.0986 -0.1062 -0.1059 -0.1105 -0.1035 -0.1059 -0.1044 -0.1074 -0.1038 -0.1050 -0.0974 -0.1093 -0.1031 -0.1022 -0.0995 -0.1050 -0.1035 -0.0916 -0.0967 -0.1086 -0.1038 -0.1111 -0.1233 -0.0845 -0.1059 -0.1035 -0.1172 -0.0970
 -0.1044 -0.1038 -0.1065 -0.1025 -0.0970 -0.1016 -0.1123 -0.1089 -0.1001 -0.0970 -0.1077 -0.1053 -0.1123 -0.1083 -0.1065 -0.1074 -0.0989 -0.1102 -0.1068 -0.1035 -0.1001 -0.1068 -0.0845 -0.0998 -0.1080 -0.1138 -0.0931 -0.1038 -0.1160 -0.1205 -0.1099
 -0.0964 -0.0955 -0.1050 -0.1056 -0.1031 -0.1035 -0.1071 -0.1004 -0.1053 -0.1007 -0.1044 -0.0998 -0.1019 -0.0964 -0.0967 -0.1016 -0.1047 -0.1056 -0.1099 -0.1089 -0.1044 -0.1123 -0.0922 -0.0937 -0.1105 -0.0934 -0.0882 -0.1038 -0.0922 -0.1035 -0.1019
 -0.1025 -0.1004 -0.1038 -0.1019 -0.1031 -0.1068 -0.1126 -0.1059 -0.1038 -0.1016 -0.1071 -0.1041 -0.1105 -0.1025 -0.1047 -0.1041 -0.0992 -0.1062 -0.1010 -0.1044 -0.1071 -0.0903 -0.0974 -0.1093 -0.1108 -0.0955 -0.0937 -0.1086 -0.1019 -0.1031 -0.1074
 -0.0977 -0.1022 -0.1065 -0.1050 -0.0970 -0.0980 -0.1062 -0.1016 -0.0992 -0.0989 -0.1022 -0.0964 -0.1050 -0.1007 -0.0967 -0.1010 -0.1099 -0.1068 -0.1062 -0.1071 -0.1059 -0.1093 -0.1074 -0.1077 -0.1007 -0.0864 -0.0967 -0.1038 -0.1044 -0.0934 -0.1099
 -0.0980 -0.0952 -0.0989 -0.0992 -0.1059 -0.1059 -0.1114 -0.1031 -0.1074 -0.1031 -0.1065 -0.1019 -0.1059 -0.0977 -0.1010 -0.1031 -0.0977 -0.1025 -0.0995 -0.1077 -0.0891 -0.1123 -0.1099 -0.0879 -0.1089 -0.1065 -0.0949 -0.0952 -0.1016 -0.0897 -0.1059
 -0.1056 -0.1028 -0.1050 -0.1001 -0.0995 -0.1007 -0.1132 -0.1074 -0.1001 -0.0974 -0.1041 -0.1041 -0.1114 -0.1035 -0.1019 -0.1031 -0.1031 -0.0989 -0.0919 -0.1044 -0.0967 -0.0888 -0.0836 -0.0970 -0.1056 -0.1123 -0.1050 -0.0888 -0.0851 -0.0967 -0.1138
 -0.0980 -0.0983 -0.1059 -0.1047 -0.1035 -0.0998 -0.1083 -0.1041 -0.1041 -0.1016 -0.1004 -0.0977 -0.1028 -0.0977 -0.0989 -0.0931 -0.1083 -0.0998 -0.0946 -0.1041 -0.1028 -0.1126 -0.0986 -0.1071 -0.1062 -0.0885 -0.1035 -0.0812 -0.1019 -0.0906 -0.1089
 -0.1013 -0.1001 -0.1019 -0.0977 -0.1004 -0.1059 -0.1105 -0.1047 -0.1059 -0.1007 -0.1071 -0.1028 -0.1093 -0.1022 -0.1004 -0.1071 -0.0986 -0.0958 -0.0882 -0.0922 -0.1047 -0.1056 -0.1102 -0.0931 -0.1108 -0.1041 -0.1089 -0.0952 -0.1089 -0.0958 -0.1144
 -0.1016 -0.1031 -0.1056 -0.1022 -0.0961 -0.0974 -0.1065 -0.1035 -0.1019 -0.0970 -0.1001 -0.0946 -0.1071 -0.1013 -0.0943 -0.0980 -0.1086 -0.1160 -0.0952 -0.0967 -0.0928 -0.0876 -0.1028 -0.0943 -0.1071 -0.1044 -0.1108 -0.0995 -0.0821 -0.1001 -0.1132
 -0.0964 -0.0986 -0.1007 -0.0989 -0.1077 -0.1041 -0.1120 -0.1068 -0.1053 -0.1059 -0.1031 -0.1016 -0.1068 -0.0964 -0.0986 -0.0989 -0.1022 -0.1111 -0.0900 -0.0946 -0.1062 -0.1123 -0.0940 -0.1047 -0.1144 -0.1111 -0.1044 -0.1044 -0.1022 -0.1053 -0.1010
 -0.1053 -0.1050 -0.1041 -0.1004 -0.0970 -0.1022 -0.1132 -0.1099 -0.0992 -0.1022 -0.1041 -0.1044 -0.1111 -0.1038 -0.1041 -0.1035 -0.1041 -0.1031 -0.0937 -0.0958 -0.0998 -0.1074 -0.0916 -0.1099 -0.1117 -0.1218 -0.1141 -0.1071 -0.1123 -0.1154 -0.1028
Attachment 2: ITE-TM4-SiC#34-LP-IG-LIS_Test_Stand.docx
Attachment 3: SiC#34.docx
Attachment 4: TS-2016-09-06-08-12.rga
  651   Wednesday, March 21, 2018, 14:11 Fernando Maldonado LP-FEBIAD  395530-342752-2In progressTest FEBIAD

Tests on coil, temperature and the use of silver bolts.

(3) Vented silver bolts on the TBHT and (2) Full silver bolts on the coil

Wednesday, March 21, 2018, 14:10: Roughing.

Wednesday, March 21, 2018, 14:30: Turbo pumps on.

Wednesday, March 21, 2018, 14:35: Ion gauge on.

Wednesday, March 21, 2018, 14:42: RGA on.


Thursday, March 22, 2018, 06:52: Waterlines opened: Vacuum stable @ 3.04e-07T

Thursday, March 22, 2018, 06:53: Power/sources on.

Thursday, March 22, 2018, 06:56: IV4 Opened.

Device Temp
[C]
 Flow
[lpm]
 HS + MSP 21.9 3.61
 TBHT 21.6 2.80
 COIL + EE 21.7 4.59
 TGHT  22.0 5.23

Thursday, March 22, 2018, 07:00: Auto ramping TGHT / TBHT to 580 / 200 A @ 2A per min.

Thursday, March 22, 2018, 07:04 : BIAS / EZL / EE @ 30 / 13 / 1.5 kV .

Thursday, March 22, 2018, 07:05: Optics on.

Thursday, March 22, 2018, 11:32: Out gassing noted. TBHT @ 200 A . TGHT @ 472 A. Ramping rate slowed automatically. Vacuum @ 3.03e-06T.

Thursday, March 22, 2018, 14:42: Out gassing continued. TGHT @ 570A.  Auto ramping TGHT / TBHT to 580 / 250 A @ undefined rate according to vacuum. Vacuum @ 3.03e-06T


Friday, March 23, 2018, 08:11: Auto ramping TBHT from 250 A to 290 A @ 2A per min. TGHT @ 580 A.

Friday, March 23, 2018, 10:20: Anode @ 100V & 8.5mA.

Friday, March 23, 2018, 10:28: Coil @ 50 A

Friday, March 23, 2018, 10:34: Anode @ 200V & 11 mA.

Friday, March 23, 2018, 13:08: RGA froze. Restart RGA


Sunday, March 25, 2018, 20:34 Vacuum stable @ 4.3e-07T . 

Sunday, March 25, 2018, 20:34: TBHT @ 290 A. TGHT @ 580 A.

Sunday, March 25, 2018, 20:34 :  Coil @ 50 A ^ 0.5 V

Sunday, March 25, 2018, 20:34 : Increasing Coil to 60 A

Sunday, March 25, 2018, 20:43: Vacuum seemed to increase to 4.4e-07T. 


Monday, March 26, 2018, 06:45: Optics on. Vacuum stable @ 4.38e-07T


Fernando

Wednesday, March 28, 2018, 08:31: Optics on. Vacuum stable @  3.57e-7T

Wednesday, March 28, 2018, 16:2: After increasing the coil current to to 75, A the coil voltage started to show an oscillating behaviour. (see image ttached)

When increased to 80 A the oscillatory behaviour increases. Reducing the current to 65A and then increasing it to 70 A showed a steady behaviour


Thursday, March 29, 2018, 15:51: Ramping down EZL, BIAS, and TGHT for the long weekend


Tuesday, April 03, 2018, 09:14: Vaccum at 1.77e-7T

Tuesday, April 03, 2018, 09:14 : Auto ramping TGHT / TBHT to 550/ 250A @ 2A per min.

Tuesday, April 03, 2018, 09:18 : BIAS / EZL / EE @ 30 / 13 / 1.5 kV  

Tuesday, April 03, 2018, 09:23 : Optics on


Wednesday, April 04, 2018, 08:39: Ramping TBHT to 290A @ 2A per min. TGHT remains @ 550 A


 Friday, April 6, 2018, afternoon: Due to inconsistencies on EPICS, Carla and I Change the Anode power supply to local in order to monitor the leakage current with a multimeter.


Monday, April 9, 2018, afternoon: TBHT@350A and TGHT@550A 

PS went current limited at AnodeBias=300V and show 3A on the PS Screen, the multimeter read the same.

Ramp down to 0 V 0A on PS. PS shows 0.01V

PS goes to limited current even at 2V.


Tuesday, April 10, 2018, 09:10: Problem persists even at lower TBHG (330A). 

The output cable was removed and the power power supply seemed to behave better. This could mean that there is a short inside the unit, in the past the anode cable had melted into the cup.

Planning to ramp down the TBHT and see if the behaviour remains. If it does, I would ask to remove the unit for inspection.

Tuesday, April 10, 2018, 09:32 : Ramping down TBHTH to 250A

Tuesday, April 10, 2018, 13:07 : Same behaviour. Cooling procedure started to see if the issue is still present, anf if it does remove unit for inspection


Wednesday, April 11, 2018, 06:44: RGA, power/sources confirmed off. IV4 closed. Ion gauge & turbos off.


Wednesday, April 18, 2018, 13:00: Post use comparison of the coil - A.S

1) Used coil from this FEBIAD = 1.999mΩ ***

2) Unused coil A = 2.421mΩ

3) unused coil B = 2.451mΩ

Attachment 1: weird-coil-voltage.PNG
weird-coil-voltage.PNG
Attachment 2: 03-04-18-RampingUp-Bias-TGHT.PNG
03-04-18-RampingUp-Bias-TGHT.PNG
Attachment 3: 29-03-18-Ramping_down_EZL-BIAS.PNG
29-03-18-Ramping_down_EZL-BIAS.PNG
Attachment 4: 180409-vacum-pike-ps-psbbly-ps-related.PNG
180409-vacum-pike-ps-psbbly-ps-related.PNG
Attachment 5: ER-580-290-30kV-m28.txt
value (Voltage offset       0.0000)
     80.0000
      0.7000
     80.0000
  29978.0220
21
21
./emit.dat
 -0.0800 -0.0839 -0.0745 -0.0735 -0.0739 -0.0714 -0.0711 -0.0696 -0.0677 -0.0757 -0.0674 -0.0674 -0.0714 -0.0723 -0.0751 -0.0748 -0.0735 -0.0748 -0.0824 -0.0806 -0.0806
 -0.0763 -0.0836 -0.0739 -0.0717 -0.0729 -0.0732 -0.0739 -0.0684 -0.0696 -0.0754 -0.0677 -0.0684 -0.0732 -0.0751 -0.0772 -0.0754 -0.0745 -0.0772 -0.0848 -0.0812 -0.0806
 -0.0772 -0.0836 -0.0717 -0.0739 -0.0723 -0.0729 -0.0742 -0.0705 -0.0714 -0.0751 -0.0656 -0.0708 -0.0714 -0.0751 -0.0714 -0.0772 -0.0769 -0.0809 -0.0772 -0.0793 -0.0742
 -0.0787 -0.0842 -0.0760 -0.0757 -0.0726 -0.0745 -0.0735 -0.0720 -0.0644 -0.0742 -0.0684 -0.0714 -0.0720 -0.0772 -0.0739 -0.0763 -0.0775 -0.0781 -0.0797 -0.0793 -0.0778
 -0.0793 -0.0815 -0.0766 -0.0766 -0.0760 -0.0723 -0.0705 -0.0690 -0.0671 -0.0726 -0.0671 -0.0708 -0.0790 -0.0729 -0.0748 -0.0757 -0.0732 -0.0751 -0.0812 -0.0778 -0.0754
 -0.0775 -0.0830 -0.0745 -0.0748 -0.0766 -0.0711 -0.0690 -0.0690 -0.0671 -0.0735 -0.0674 -0.0693 -0.0732 -0.0745 -0.0742 -0.0754 -0.0723 -0.0757 -0.0818 -0.0797 -0.0763
 -0.0769 -0.0806 -0.0742 -0.0748 -0.0681 -0.0723 -0.0726 -0.0702 -0.0684 -0.0745 -0.0674 -0.0696 -0.0729 -0.0757 -0.0729 -0.0760 -0.0748 -0.0763 -0.0806 -0.0797 -0.0769
 -0.0772 -0.0824 -0.0754 -0.0751 -0.0742 -0.0726 -0.0714 -0.0717 -0.0696 -0.0754 -0.0677 -0.0708 -0.0723 -0.0717 -0.0720 -0.0757 -0.0760 -0.0775 -0.0790 -0.0784 -0.0745
 -0.0790 -0.0815 -0.0763 -0.0757 -0.0732 -0.0720 -0.0717 -0.0742 -0.0681 -0.0751 -0.0677 -0.0717 -0.0726 -0.0705 -0.0732 -0.0757 -0.0763 -0.0766 -0.0790 -0.0787 -0.0790
 -0.0772 -0.0833 -0.0760 -0.0778 -0.0739 -0.0714 -0.0714 -0.0702 -0.0674 -0.0751 -0.0668 -0.0699 -0.0717 -0.0726 -0.0754 -0.0757 -0.0757 -0.0751 -0.0803 -0.0787 -0.0766
 -0.0781 -0.0827 -0.0745 -0.0739 -0.0742 -0.0717 -0.0699 -0.0702 -0.0674 -0.0705 -0.0665 -0.0690 -0.0726 -0.0745 -0.0745 -0.0772 -0.0757 -0.0766 -0.0797 -0.0787 -0.0784
 -0.0760 -0.0818 -0.0739 -0.0720 -0.0720 -0.0742 -0.0708 -0.0726 -0.0662 -0.0687 -0.0668 -0.0705 -0.0720 -0.0745 -0.0726 -0.0757 -0.0742 -0.0790 -0.0818 -0.0797 -0.0790
 -0.0781 -0.0824 -0.0748 -0.0748 -0.0732 -0.0723 -0.0696 -0.0708 -0.0690 -0.0739 -0.0684 -0.0699 -0.0729 -0.0732 -0.0739 -0.0754 -0.0757 -0.0769 -0.0803 -0.0797 -0.0803
 -0.0797 -0.0842 -0.0754 -0.0775 -0.0732 -0.0732 -0.0717 -0.0720 -0.0684 -0.0720 -0.0668 -0.0717 -0.0708 -0.0723 -0.0769 -0.0763 -0.0757 -0.0751 -0.0766 -0.0790 -0.0757
 -0.0787 -0.0851 -0.0754 -0.0812 -0.0735 -0.0717 -0.0717 -0.0690 -0.0668 -0.0699 -0.0659 -0.0699 -0.0723 -0.0723 -0.0748 -0.0763 -0.0726 -0.0745 -0.0784 -0.0797 -0.0745
 -0.0781 -0.0830 -0.0754 -0.0735 -0.0739 -0.0708 -0.0711 -0.0717 -0.0677 -0.0677 -0.0665 -0.0696 -0.0717 -0.0742 -0.0720 -0.0754 -0.0732 -0.0763 -0.0797 -0.0781 -0.0754
 -0.0760 -0.0812 -0.0748 -0.0760 -0.0708 -0.0705 -0.0702 -0.0732 -0.0668 -0.0699 -0.0677 -0.0696 -0.0729 -0.0732 -0.0708 -0.0757 -0.0754 -0.0766 -0.0812 -0.0787 -0.0769
 -0.0787 -0.0830 -0.0742 -0.0739 -0.0726 -0.0720 -0.0693 -0.0739 -0.0690 -0.0714 -0.0681 -0.0708 -0.0739 -0.0726 -0.0739 -0.0763 -0.0769 -0.0781 -0.0833 -0.0806 -0.0778
 -0.0781 -0.0827 -0.0760 -0.0787 -0.0739 -0.0732 -0.0708 -0.0720 -0.0668 -0.0729 -0.0677 -0.0711 -0.0717 -0.0735 -0.0763 -0.0754 -0.0763 -0.0754 -0.0793 -0.0815 -0.0787
 -0.0787 -0.0833 -0.0766 -0.0818 -0.0745 -0.0739 -0.0717 -0.0717 -0.0668 -0.0699 -0.0647 -0.0693 -0.0717 -0.0742 -0.0751 -0.0781 -0.0760 -0.0739 -0.0790 -0.0790 -0.0754
 -0.0787 -0.0824 -0.0757 -0.0751 -0.0754 -0.0717 -0.0708 -0.0717 -0.0674 -0.0684 -0.0656 -0.0681 -0.0729 -0.0739 -0.0745 -0.0760 -0.0735 -0.0745 -0.0781 -0.0784 -0.0775
Attachment 6: ER-580-290-30kV-m39.txt
value (Voltage offset       0.0000)
     80.0000
      0.7000
     80.0000
  29978.0220
21
21
./emit.dat
 -0.0739 -0.0793 -0.0757 -0.0714 -0.0739 -0.0708 -0.0684 -0.0696 -0.0668 -0.0739 -0.0653 -0.0659 -0.0668 -0.0702 -0.0735 -0.0732 -0.0723 -0.0766 -0.0778 -0.0812 -0.0809
 -0.0739 -0.0790 -0.0769 -0.0699 -0.0754 -0.0739 -0.0690 -0.0684 -0.0702 -0.0739 -0.0656 -0.0656 -0.0671 -0.0705 -0.0717 -0.0720 -0.0735 -0.0760 -0.0784 -0.0836 -0.0800
 -0.0729 -0.0757 -0.0766 -0.0705 -0.0742 -0.0705 -0.0720 -0.0714 -0.0708 -0.0735 -0.0659 -0.0665 -0.0677 -0.0723 -0.0705 -0.0720 -0.0745 -0.0778 -0.0739 -0.0803 -0.0748
 -0.0717 -0.0769 -0.0781 -0.0726 -0.0632 -0.0699 -0.0696 -0.0714 -0.0684 -0.0742 -0.0687 -0.0653 -0.0717 -0.0739 -0.0711 -0.0708 -0.0754 -0.0751 -0.0742 -0.0806 -0.0772
 -0.0720 -0.0766 -0.0763 -0.0729 -0.0681 -0.0681 -0.0681 -0.0708 -0.0714 -0.0720 -0.0677 -0.0659 -0.0708 -0.0711 -0.0732 -0.0739 -0.0723 -0.0705 -0.0760 -0.0797 -0.0742
 -0.0720 -0.0760 -0.0732 -0.0790 -0.0693 -0.0696 -0.0671 -0.0723 -0.0671 -0.0705 -0.0659 -0.0674 -0.0717 -0.0702 -0.0726 -0.0729 -0.0729 -0.0748 -0.0781 -0.0778 -0.0766
 -0.0739 -0.0748 -0.0726 -0.0723 -0.0665 -0.0702 -0.0677 -0.0714 -0.0684 -0.0729 -0.0668 -0.0681 -0.0717 -0.0699 -0.0705 -0.0742 -0.0729 -0.0757 -0.0775 -0.0797 -0.0766
 -0.0742 -0.0766 -0.0742 -0.0671 -0.0702 -0.0693 -0.0677 -0.0696 -0.0696 -0.0751 -0.0677 -0.0659 -0.0671 -0.0702 -0.0702 -0.0720 -0.0745 -0.0760 -0.0754 -0.0809 -0.0790
 -0.0729 -0.0766 -0.0778 -0.0702 -0.0674 -0.0668 -0.0693 -0.0711 -0.0693 -0.0751 -0.0674 -0.0681 -0.0690 -0.0693 -0.0708 -0.0717 -0.0742 -0.0745 -0.0729 -0.0797 -0.0742
 -0.0711 -0.0769 -0.0772 -0.0720 -0.0708 -0.0690 -0.0674 -0.0720 -0.0696 -0.0748 -0.0677 -0.0690 -0.0720 -0.0720 -0.0729 -0.0751 -0.0739 -0.0726 -0.0748 -0.0775 -0.0781
 -0.0723 -0.0748 -0.0766 -0.0797 -0.0662 -0.0681 -0.0662 -0.0699 -0.0681 -0.0714 -0.0671 -0.0671 -0.0677 -0.0729 -0.0720 -0.0745 -0.0745 -0.0757 -0.0778 -0.0790 -0.0754
 -0.0729 -0.0754 -0.0754 -0.0754 -0.0690 -0.0693 -0.0681 -0.0711 -0.0677 -0.0711 -0.0650 -0.0668 -0.0671 -0.0705 -0.0717 -0.0711 -0.0723 -0.0769 -0.0748 -0.0806 -0.0775
 -0.0732 -0.0790 -0.0763 -0.0726 -0.0677 -0.0687 -0.0690 -0.0732 -0.0705 -0.0732 -0.0665 -0.0659 -0.0684 -0.0677 -0.0711 -0.0735 -0.0732 -0.0732 -0.0729 -0.0821 -0.0772
 -0.0729 -0.0797 -0.0766 -0.0732 -0.0674 -0.0668 -0.0677 -0.0729 -0.0699 -0.0739 -0.0677 -0.0693 -0.0729 -0.0699 -0.0717 -0.0742 -0.0720 -0.0705 -0.0763 -0.0809 -0.0778
 -0.0729 -0.0772 -0.0766 -0.0745 -0.0677 -0.0662 -0.0684 -0.0732 -0.0708 -0.0717 -0.0662 -0.0708 -0.0778 -0.0714 -0.0735 -0.0748 -0.0745 -0.0739 -0.0757 -0.0781 -0.0751
 -0.0726 -0.0745 -0.0754 -0.0720 -0.0702 -0.0677 -0.0693 -0.0723 -0.0677 -0.0708 -0.0677 -0.0684 -0.0693 -0.0723 -0.0720 -0.0726 -0.0748 -0.0763 -0.0748 -0.0800 -0.0751
 -0.0739 -0.0763 -0.0763 -0.0717 -0.0705 -0.0690 -0.0690 -0.0717 -0.0677 -0.0714 -0.0647 -0.0665 -0.0757 -0.0696 -0.0702 -0.0720 -0.0732 -0.0766 -0.0751 -0.0815 -0.0790
 -0.0748 -0.0781 -0.0760 -0.0754 -0.0714 -0.0699 -0.0690 -0.0714 -0.0684 -0.0714 -0.0653 -0.0665 -0.0702 -0.0693 -0.0699 -0.0726 -0.0726 -0.0735 -0.0751 -0.0809 -0.0778
 -0.0757 -0.0790 -0.0763 -0.0742 -0.0665 -0.0681 -0.0684 -0.0760 -0.0708 -0.0732 -0.0681 -0.0681 -0.0671 -0.0711 -0.0714 -0.0745 -0.0732 -0.0720 -0.0766 -0.0787 -0.0772
 -0.0732 -0.0763 -0.0769 -0.0732 -0.0671 -0.0684 -0.0684 -0.0693 -0.0708 -0.0735 -0.0684 -0.0696 -0.0690 -0.0720 -0.0729 -0.0751 -0.0745 -0.0748 -0.0748 -0.0781 -0.0754
 -0.0732 -0.0754 -0.0751 -0.0754 -0.0656 -0.0668 -0.0696 -0.0711 -0.0684 -0.0705 -0.0659 -0.0693 -0.0699 -0.0711 -0.0717 -0.0735 -0.0729 -0.0754 -0.0748 -0.0803 -0.0763
Attachment 7: FEBIAD_coil_and_temp_2018.docx
Attachment 8: TS-2018-03-21-14-38.rga
Attachment 9: TS-2018-03-23-13-08.rga
Attachment 10: TS-2018-03-27-13-17.rga
  695   Thursday, November 08, 2018, 10:54 Aaron Schmidt LP-FEBIAD  395530-342752-5In progressTest FEBIAD w/ Silver bolts & sealed end caps

Silver bolts used on Coil, TGHT, & TBHT. Back panel opened for new gas bottles.

Thursday, November 08, 2018, 10:52: Roughing

Thursday, November 08, 2018, 10:53: Doors sealed.

Thursday, November 08, 2018, 14:10: Turbo pumps started.

Thursday, November 08, 2018, 14:15: Ion gauge on.

Thursday, November 08, 2018, 14:23: RGA on.


Friday, November 09, 2018, 07:38: Waterlines opened. No response on RGA. Vacuum ok @ 5.18e-07T

Friday, November 09, 2018, 07:44 : Slowly start opening gas lines. Opened / closed SV5 initially, no response. Note* Opened SV3 with SV5 closed. Massive spike seen in vacuum.

Friday, November 09, 2018, 07:55 : SV3 opened / closed in conjunction with SV5 until stable vacuum reached. Begin opening SV4 w/ SV5 closed.

Friday, November 09, 2018, 08:09 : SV3 & SV4 opened with SV5, Stable vacuum reached. Begin opening SV2/SV1 w/ SV5 closed.

Friday, November 09, 2018, 08:15: All gas lines opened. Sources on.

Friday, November 09, 2018, 08:22: BIAS / EZL / EE @ 30 / 13.5 / 1.5 kV. Anode @ 200 V. IV4 opened. Optics switched on.

Friday, November 09, 2018, 08:40: Auto-ramping TGHT / TBHT to 580 / 300 A @ 2A per min. Loop to max values, increase of 0A until vacuum gets below 1.0e-06T. Vacuum 1.12e-06T.

Friday, November 09, 2018, 10:45: The vacuum wouldn't drop below 1.12e-06T. Ramping halted and gas lines closed. Vacuum dropped to 7.48e-07T. Gas lines opened again. Vacuum stable around 1.12e-06T. Significant Argon noted on RGA.

Friday, November 09, 2018, 10:52: Auto-ramping TGHT / TBHT to 450 / 200 A @ 2A per min. Vacuum increment limit increased to 2.0e-06T


Tuesday, November 13, 2018, 08:32: Auto-ramping TGHT / TBHT to 580 / 300 A @ 2A per min.

Tuesday, November 13, 2018, 11:08: Mass scans ok. Auto-ramping TBHT to 330 A @ 2A per min.

FM

Tuesday, November 13, 2018, 16:44: The anode drain current has increased 17mA since 11:23 am, however FC0 is still decreasing. I will keep monitoring to see if the behaviour of the anode drain current continues once FC0 has stabilized. If the anode drain current keeps increasing maybe we will observe the same failure from the previous FEBIAD.


FM

Wednesday, November 14, 2018, 11:02 FC0 is stable but the anode drain current is still increasing and now is at 85 mA. It started at ~52mA. From the strip tool it seems to be a 2-hour period where the anode drain current is stable.

Wednesday, November 14, 2018, 16:14 : Magnet tune for 40Ar. TMS:MB1=101.56126 A

Coil=50 A. FC6=19.37 nA

Wednesday, November 14, 2018, 16:16 : Closing Neon valve.

Wednesday, November 14, 2018, 16:26 : FC6=13.77 nA.

Wednesday, November 14, 2018, 16:27: Closing Argon valve 

Wednesday, November 14, 2018, 17:10: 0.119 nA.

Wednesday, November 14, 2018, 17:15 Assuming the 720 nA from Brad (I will recompute this value based on the new bottles). Efficiency with both gasses open= 2.67375% . Efficiecy with Argon bottle only=1.84%. Anode drain current~87.5mA

 Wednesday, November 14, 2018, 17:53: When opening the Neon valve, the vacuum reached ~1e-5 T and the test stand tripped. Ion source off, high voltage and some of the optics as well. Leaving the test stand as is. 

Wednesday, November 14, 2018, 17:58: Note to myself: How am i gonna take an efficiency measurement if every time I turned the gas valves the vacuum will increase to 1e-5 T. 


Thursday, November 15, 2018, 08:33: Sources at zero. Bring values to 0 before restarting. Reset optics.

Thursday, November 15, 2018, 08:45: Power to sources off. Open the back & double check gas bottles. All are tight.

Thursday, November 15, 2018, 09:35: All gas bottles opened.

Thursday, November 15, 2018, 09:58: Power/sources reset/on.

Thursday, November 15, 2018, 10:04: BIAS / EZL / EE @ 30 / 13.5 / 1.5 kV. Anode @ 200 V. IV4 opened. 

Thursday, November 15, 2018, 10:05: Auto-ramping TGHT / TBHT to 580 / 300 A @ 2A per min.

Thursday, November 15, 2018, 10:07: Optics reset.

FM

 Thursday, November 15, 2018, 18:46: Coil to 50 A. 


Friday, November 16, 2018, 08:40: Emittance Rig reset & calibrated.

 FM

Friday, November 16, 2018, 11:30 : Auto-ramping  TBHT to 310 A @ 1A per min.

Friday, November 16, 2018, 16:28 Friday, November 16, 2018, 16:28 : Gain in FC0 seems off. Reading on FC0 was 2.8e-8A but reading on FC6 was 4.5e-8A. In the last mass scan, I add up the highest peaks above 1e-9A  and the values was roughly 7e-8A. Switching the gain to 94uA in FCO shows 8.32e-8 A. This seems a better reading than before.

Friday, November 16, 2018, 16:30 Changing gacin on FC0 from 1 uA to 94 uA.


FM

Monday, November 19, 2018, 09:34 : Scanning from 0-450 V and recording Anode drain current.

IG1 reading is 3.01e-6 T.

Monday, November 19, 2018, 10:01 : When Moving away FC0, the optics goes yellow. Not sure which interlock is activated.

AS

Optics tripped during FC0 removal. Vacuum spikes also detected on IG1 & IG6. No response on RGA.

Monday, November 19, 2018, 11:17: RGA providing no data. Stop, restart, multiple times. 

Monday, November 19, 2018, 11:25: RGA shut down. No response from and attempt to restart. 

Monday, November 19, 2018, 11:30: FC0 opened. Optics tripped. Vacuum increased on IG6 up to 7.9e-06T & IG1 increased to 4.4e-06T. Shut again to avoid tripping the entire system as the vacuum climbed.

Monday, November 19, 2018, 11:34: Auto-cooling @ 2A per min. Ramp down & trouble shoot after.

Monday, November 19, 2018, 14:11: Tap down HV on sources to 0V. Close & reset IV4. After closing IV4, spike in Vacuum on IG6 noted. Drop in vacuum on IG1 noted.

  700   Wednesday, December 12, 2018, 13:22 Aaron Schmidt LP-FEBIAD  395530-342752-5In progressAnode leak current check.

Wednesday, December 12, 2018, 13:15: Power / Sources on.

Wednesday, December 12, 2018, 13:20: RGA on / set.

Wednesday, December 12, 2018, 13:29: BIAS / EZL / EE @ 30 / 13.5 / 1.5 kV.

Wednesday, December 12, 2018, 13:30: Auto-ramping TGHT / TBHT to 10A @ 2A per min.

Wednesday, December 12, 2018, 13:36: IV4 open.

Wednesday, December 12, 2018, 13:37: Begin Anode check

Anode: 10 V. Current: 0.000 mA

Anode: 25 V. Current: 0.000 mA

Anode: 50 V. Current: 0.000 mA

Anode: 75 V. Current: 0.000 mA

Anode: 100 V. Current: 0.000 mA

Anode: 125 V. Current: 0.000 mA

Anode: 150 V. Current: 0.000 mA

Anode: 200 V. Current: 0.000 mA

Anode: 250 V. Current: 0.000 mA

Wednesday, December 12, 2018, 13:42: Coil to 10A. Anode: 250 V. Current: 0.000 mA

Wednesday, December 12, 2018, 13:43: Coil to 25A. Anode: 250 V. Current: 0.000 mA

Wednesday, December 12, 2018, 13:56: Auto-ramping TGHT / TBHT to 150A @ 2A per min.

Wednesday, December 12, 2018, 14:09: Auto-ramping halted @ 35A. Anode to 0 V. Monitor activity on FC0. 5 minutes.

Wednesday, December 12, 2018, 14:13: No changes observed on FC0. Anode back to 250 V.

Wednesday, December 12, 2018, 14:14: Auto-ramping TGHT / TBHT to 150A @ 2A per min.

Wednesday, December 12, 2018, 14:31: Optics all reset. 


Thursday, December 13, 2018, 07:31: Auto-ramping TGHT / TBHT to 200A @ 2A per min.

Thursday, December 13, 2018, 10:04: Auto-ramping TGHT / TBHT to 250A @ 2A per min.

FM Thursday, December 13, 2018, 10:40 : Auto-ramping TGHT / TBHT to 270A @ 2A per min.

FM Thursday, December 13, 2018, 12:44: Auto-ramping TGHT / TBHT to 290A @ 2A per min. 

FM Thursday, December 13, 2018, 12:56: FC0 gain set to 33nA

FM Thursday, December 13, 2018, 16:54: Anode drain current register at 310. Value was 1 mA. The resistor calculates is 30kOhm. Which is close to what was measured on the resistor on top 34kOhm.

With this new information. I will let the TBHT@290A and the TGHT@300A overnight.

Note to Aaron: Could you please heat up the target to 580A with the current settings we have.


Friday, December 14, 2018, 07:04:  Auto-ramping TGHT 580A @ 2A per min. TBHT remains @ 290 A. FC0 back in.

Friday, December 14, 2018, 14:15: Anode @ 250 V & 12.201 mA.

Friday, December 14, 2018, 14:22: BIAS /  EZL / EE to 0 V. Anode remains unchanged.

FM Friday, December 14, 2018, 18:04: TBHT down to 50. Anode drain current is still 12.21mA.

FM Friday, December 14, 2018, 18:05 Auto-cooling. i will keep monitoring the strip tools remotely.

  701   Monday, December 17, 2018, 12:03 Aaron Schmidt LP-FEBIAD  395530-342752-5 Anode leak current check.

Monday, December 17, 2018, 12:01: Connected Multimeter through feedthroughs J & L. Blue wire removed.

To run TGHT, TBHT, Anode ONLY. HV will remain locked with yellow tape over the keyhole. Currently locked out.


Tuesday, December 18, 2018, 08:37: Power / sources on

TGHT, TBHT, Anode, Coil on. NO HV.

Tuesday, December 18, 2018, 08:40: Turn off. Anode reading before PS on?

We found a steady climb on the Anode current via the epics controls, however no reading turned up on the multimeter. Disappears once the Anode PS is switched on.

Tuesday, December 18, 2018, 08:46: Power / sources on

TGHT, TBHT, Anode, Coil on. NO HV.

Tuesday, December 18, 2018, 08:49: Auto-ramping TGHT to 580 A @ 2 A per min.

Tuesday, December 18, 2018, 08:50: Anode set to 300 V.

 FM Tuesday, December 18, 2018, 13:42: TGHT @ 580 A Anode@300 V. Epics and the power supply shows ~20 mA. However the multimeter doesn't show any reading.

FM Tuesday, December 18, 2018, 14:25: Strange behavior noted on EE while doing the anode voltage scan. Screenshot added to the word document.

FM Tuesday, December 18, 2018, 14:25: Auto-ramping TBHT to 100 A @ 2 A per min

FM Tuesday, December 18, 2018, 15:40: Auto-ramping TBHT to 150 A @ 2 A per min

FM Tuesday, December 18, 2018, 16:26: Auto-ramping TBHT to 200 A @ 2 A per min

FM Tuesday, December 18, 2018, 17:08: Auto-ramping TBHT to 250 A @ 2 A per min

FM Tuesday, December 18, 2018, 17:38: Auto-ramping TBHT to 300 A @ 2 A per min

FM Tuesday, December 18, 2018, 17:20: Auto-ramping TBHT to 250 A @ 2 A per min

FM Tuesday, December 18, 2018, 18:37 : Nothing register on the multimeter, maybe we need to connect between A-B, or B-F. Cooling down to inspect the multimeter connection tomorrow.

FM Tuesday, December 18, 2018, 18:37: Auto-cooling TBHT/TGHT@ 2 A per min


FM Wednesday, December 19, 2018, 09:29: For the lasts 10 hours, the anode drain current has shown a steady value of 10.989 mA even though both the TBHT and the TGHT are off.

FM Wednesday, December 19, 2018, 10:47: Power supplies turned off in EPICS, Anode drain current still shows 4.839 on the readback.

Wednesday, December 19, 2018, 14:25: Power / Sources on. Anode to 300 V. - AS

Wednesday, December 19, 2018, 14:26: Auto-ramping TGHT to 300 A @ 2 A per min. - AS


Thursday, December 20, 2018, 06:42: Auto-ramping TGHT to 580 A @ 2 A per min. - AS

FM Thursday, December 20, 2018, 11:12 : Auto-ramping TBHT to 200 A @ 2 A/min

Thursday, December 20, 2018, 13:05 (Roughly) Power bump due to winds. Full TS shutdown.

  702   Thursday, December 20, 2018, 13:55 Aaron Schmidt LP-FEBIAD  395530-342752-5 Holiday shut down.

High winds caused a brief power outage that completely shutoff the ISAC test stand.

Locked out the power.

RGA checked & shutoff complete

Epics failure, computer restarted.

Thursday, December 20, 2018, 13:52: Shutting ISAC test stand down for the holidays. Checking Epics & operation first.

Thursday, December 20, 2018, 13:55: Roughing pump operating. Turbos left off. Backing valves opened. Epics whiteout on TS sources & optics.

TBHT, TGHT, Anode all brought to zero on epics, although still mostly white out.

Thursday, December 20, 2018, 14:14: Waterlines shut off at the main source & the TS is purged.

Note* Small leak directly on the fittings noticed on FS#5 right after the flow meter paddle wheel on the supply end.  All water flow was briefly halted during the power bump.

Epics still whited out.


Monday, January 07, 2019, 11:13: Fault report 11981 submitted.

  703   Tuesday, January 08, 2019, 08:11 Aaron Schmidt LP-FEBIAD  395530-342752-5In progressTS restart

Tuesday, January 08, 2019, 08:00: Epics white out fixed. Ref: Fault report 11981.

Tuesday, January 08, 2019, 08:10: IV4 reset. Turbo Pumps on

TMS:IG6 & TSG:IG1 not responding. Timing out. Edi contacted

TMS:IG6 - Filament switched on controller.

TSG:IG1 - Filament switched over. Cable to ion gauge is burnt. Black wire inside the housing had melted along with the edges of the plastic. Replaced the entire cable & reconnected the ion gauge to the controller.

Tuesday, January 08, 2019, 08:48: IG6 & IG1 operation resumed. Vacuum pump down continued.

Tuesday, January 08, 2019, 08:55: FS5 waterline tightened for leak check. All lines closed.

Tuesday, January 08, 2019, 09:03: RGA restarted/on.

Tuesday, January 08, 2019, 09:05: Opening waterlines. vacuum at 2.66e-06T. Control room notified.

Tuesday, January 08, 2019, 09:10: Waterlines opened. Vacuum @ 2.57e-06T. No response on RGA.

Tuesday, January 08, 2019, 09:14: No leak noted on the FS#5 paddle wheel. Fixed with tightening.

Tuesday, January 08, 2019, 09:20: Control room noted 7.6L fill (1/4" drop approx) in DI water on this line. (Note this next year)

  716   Friday, April 05, 2019, 07:02 Aaron Schmidt LP-FEBIAD  395530-342752-5In progressTS operation test - LP FEBIAD

Due to previous issues, a full run / test should be performed on the ISAC Test Stand.

Friday, April 05, 2019, 07:00: RGA on.

Friday, April 05, 2019, 07:03: Begin opening / closing gas lines until they can be opened & stable.

Friday, April 05, 2019, 07:14: Gas lines open.

Friday, April 05, 2019, 07:16: Power / sources on. Vacuum down to 1.25e-06T

Friday, April 05, 2019, 07:18: Optics on & Set.

Friday, April 05, 2019, 07:19: IV4 Opened.

Friday, April 05, 2019, 07:21: Auto-ramping TGHT / TBHT to 300 / 200 A @ 2A per min

Friday, April 05, 2019, 07:28: BIAS / EZL / EE @ 30 / 13 / 1.5 kV. Anode @ 200 V.

Friday, April 05, 2019, 09:40: Auto-ramping TGHT / TBHT to 580 / 290 A @ 2A per min 

Friday, April 05, 2019, 14:01: Beam on FC0 & wire scans. Mass scan provides no reading. (Max current after CONST2 has changed). Inquire why.

No sparks have occurred on this run. Operationally, appears the PS switches were effective.

Friday, April 05, 2019, 14:05: Begin auto-cooling @ 2A per min.

Friday, April 05, 2019, 14:56 : BIAS / EZL / EE @ 0 kV. Anode @ 0 V.


Monday, April 08, 2019, 06:57: RGA off. Gas lines closed. IV4 Closed.

Monday, April 08, 2019, 07:01: Power / Sources off.

Monday, April 08, 2019, 07:01: IG1 off. Turbo pumps off.

Monday, April 08, 2019, 08:11: Venting.

Attachment 1: TS_-_New_BIAS__EZL_Testing_-_2019.docx
Attachment 2: TS-2019-04-05-07-00.rga
ELOG V2.9.2-2455