ID |
Date |
Author |
Target/No.# |
Source |
Station |
Module |
Target Oven W.O# |
Heat Shield W.O# |
Status |
Subject |
583
|
Wednesday, May 10, 2017, 15:07 |
Aaron Schmidt | | | | | | | | Pump down empty chamber. (FS#3 out) | FS#3 lines blanked off.
Wednesday, May 10, 2017, 14:40: Roughing
Wednesday, May 10, 2017, 15:05: Turbos on.
Wednesday, May 10, 2017, 15:10: Ion gauge on.
Disconnect Leak detector. Connect He to FS#3 (G) line.
Thursday, May 11, 2017, 07:44: RGA on.
Thursday, May 11, 2017, 08:23: Vacuum @ 1.85e-06T. He line pressurized to 50 PSI. Monitor RGA.
Thursday, May 11, 2017, 09:07: No response on RGA. Vacuum @ 1.85e-06T. Purge Helium.
Hook up dry system leak detector to leak check valve behind turbo.
Leak rate: 0.0e-09 atm-cc/sec on detector. T.P: 0.0e-04T.
Thursday, May 11, 2017, 09:18: Open check valve. Vacuum ok @ 1.76e-06T
Base leak rate: 2.5e-09 atm-cc/sec.
Thursday, May 11, 2017, 09:25: Open He & Pressurize to 50 PSI.
Thursday, May 11, 2017, 09:30: Base leak rate dropping slowly: 2.0e-09 atm-cc/sec. No leak detected. No response on RGA.
Thursday, May 11, 2017, 09:35: Base leak rate dropping slowly: 1.7e-09 atm-cc/sec. No leak detected. No response on RGA.
Thursday, May 11, 2017, 09:45: Base leak rate Ok: 1.7e-09 atm-cc/sec. No leak detected. No response on RGA. Close check valve. Purge line. Vent detector.
Leak detector on. Leak rate: 0.0e-09 atm-cc/sec on detector. T.P: 0.0e-04T.
Thursday, May 11, 2017, 13:24: Open check valve. Vacuum @ 1.41e-06T
Base leak rate: @.2.0e-09 atm-cc/sec.
Thursday, May 11, 2017, 13:30: Open He & Pressurize to 50 PSI.
Thursday, May 11, 2017, 13:37: Base leak rate dropping slowly: 1.0e-09 atm-cc/sec. No leak detected. No response on RGA.
Thursday, May 11, 2017, 13:40: Base leak rate Ok: 0.1e-09 atm-cc/sec. No leak detected. No response on RGA. Vent He.
Connect spray nozzle to He. Vacuum issue noticed on RGA: N & O. Check for leak on Chamber
Tuesday, May 16, 2017, 08:45: RGA off. Ion gauge off. Turbos off
Tuesday, May 16, 2017, 09:50: Venting |
Attachment 1: 05-11-2017_Water_leak.docx
|
584
|
Tuesday, May 16, 2017, 14:25 |
Aaron Schmidt | | HP-FEBIAD-CTL | | | | | | Tri-Coil CTL-FEBIAD test III | Coil loose (Remove lid, Tighten and place lid again)
Tuesday, May 16, 2017, 14:24: Roughing.
Tuesday, May 16, 2017, 14:45: Turbo pumps on.
Wednesday, May 17, 2017, 06:53: RGA on. Vacuum @ 7.40e-07T
Wednesday, May 17, 2017, 08:04: Open waterline FS#5. OK. Vacuum @ 6.93e-07T
Wednesday, May 17, 2017, 08:05: Open waterline FS#4. OK.
Wednesday, May 17, 2017, 08:06: Open waterline FS#2. OK.
Wednesday, May 17, 2017, 08:07: Open waterline FS#3. OK.
Wednesday, May 17, 2017, 08:10: Vacuum @ 6.93e-07T. No response on RGA
Wednesday, May 17, 2017, 08:26: RGA Error out. Restart RGA.
Wednesday, May 17, 2017, 08:35: Vacuum ok @ 6.87e-07T. RGA ok.
Sparking issues
Wednesday, May 17, 2017, 13:00:
BIAS / EZL / EE @ 35 / 13 / 1.5 kV .
Coil @ 50 A . Anode @ 200 V
RGA Fatal errors. unable to restart. Reboot in morning.
Wednesday, May 17, 2017, 14:25: Auto ramping TGHT / TBHT to 300 / 150 A @ 2/1 A per min.
Wednesday, May 17, 2017, 15:05: BIAS / EZL / EE @ 30 / 13 / 1.5 kV .
Thursday, May 18, 2017, 08:27: Auto ramping TGHT / TBHT to 400 / 200 A @ 2/1 A per min.
Thursday, May 18, 2017, 08:33: RGA on.
Thursday, May 18, 2017, 08:37: IV4 opened
Thursday, May 18, 2017, 08:42: Optics on/set
Monday, May 22, 2017, 07:55: RGA, Power/Sources off.
Monday, May 22, 2017, 07:59: Turbo pumps, Ion gauge off.
Monday, May 22, 2017, 09:03: Venting
Monday, May 22, 2017, 09:40: 6 block screws tightened. |
Attachment 1: CTL_FEBIAD_Test_target_III.docx
|
Attachment 2: TS-2017-05-17-13-00.rga
|
Attachment 3: TS-2017-05-17-13-30.rga
|
Attachment 4: TS-2017-05-18-08-30.rga
|
Attachment 5: CTL_FEBIAD_Test_target_II_(Spark_out).docx
|
Attachment 6: TS-2017-05-17-06-55.rga
|
Attachment 7: TS-2017-05-17-08-30.rga
|
Attachment 8: TS-2017-05-17-12-33.rga
|
586
|
Monday, May 22, 2017, 09:43 |
Aaron Schmidt | | HP-FEBIAD-CTL | | | | | | Tri-Coil CTL-FEBIAD test IV | Monday, May 22, 2017, 09:41: Roughing.
Monday, May 22, 2017, 10:00: Turbo pumps started.
Tuesday, May 23, 2017, 07:45: Power/sources on.
Tuesday, May 23, 2017, 07:58: BIAS / EZL / EE @ 35 / 13 / 1.5 kV .
Tuesday, May 23, 2017, 08:19: Coil @ 50 A . Anode @ 200 V
Tuesday, May 23, 2017, 08:20: Auto ramping TGHT / TBHT to 580 / 270 A @ 2 A per min.
Tuesday, May 23, 2017, 10:22: IV4 opened.
Tuesday, May 23, 2017, 10:57: Increased ramping rate for TGHT to 4 A/min - AM
Tuesday, May 23, 2017, 19:05: Cooling down target for change to Anode bias tomorrow. - AM
Tuesday, May 23, 2017, 21:04: BIAS/EZL/EE off
Wednesday, May 24, 2017, 07:16: IV4 Closed.
Wednesday, May 24, 2017, 07:18: Power/Sources off.
Changed to Anode Bias.
Wednesday, May 24, 2017, 11:00: Coil @ 50 A . Anode @ 200 V
Wednesday, May 24, 2017, 11:02: Auto ramping TGHT / TBHT to 580 / 270 A @ 4 / 2 A per min.
Wednesday, May 24, 2017, 11:09: BIAS / EZL / EE @ 35 / 13 / 1.5 kV .
Tuesday, May 30, 2017, 07:02: Auto Cooling @ 2A/min
Thursday, June 01, 2017, 14:08: IV4 Closed. RGA off.
Thursday, June 01, 2017, 14:10: Ion gauge off. Turbos off.
Thursday, June 01, 2017, 16:51: Venting
Thursday, June 01, 2017, 21:16: Roughing. |
Attachment 1: CTL_FEBIAD_Test_IV.docx
|
Attachment 2: TS-2017-05-22-10-07.rga
|
Attachment 3: TS-2017-05-25-15-42.rga
|
588
|
Friday, June 02, 2017, 15:57 |
Aaron Schmidt | SiC#36 | HP-FEBIAD-CTL | ITW | TM2 | 41369-10 | 42132-6/9 | | Conditioning SiC#36 | Friday, June 02, 2017, 15:20: Coil loose (Remove lid, Tighten and place lid again)
Friday, June 02, 2017, 15:52: Roughing
Friday, June 02, 2017, 16:13: Turbo pumps on.
Friday, June 02, 2017, 16:18: Ion gauge on
Friday, June 02, 2017, 16:23: RGA on
By Anders
Saturday, June 03, 2017, 09:07: Opened HS water supply. In/out 95 / 10 psi. 3.8 lpm. Vacuum stable at 3.3E-7 Torr
Saturday, June 03, 2017, 09:08: Open IV4
Saturday, June 03, 2017, 09:32: Opening gas bottles. Source on. Reconfigured in Cathode bias
Saturday, June 03, 2017, 09:41: Started autoramping to 580 / 250 A at 2 A/min
Saturday, June 03, 2017, 09:42: COIL at 70 A, ANODE at 200 V
Saturday, June 03, 2017, 09:42: BIAS / EL / EE at 30 / 13 / 1.5 kV
Saturday, June 03, 2017, 09:47
Daqpro time 9:33
Device |
Flow [lpm] |
Temp [C] |
HS + MSP |
3.8 |
26 |
TBHT |
3.1 |
27 |
COIL + EE |
4.9 |
26 |
TGHT |
5.5 |
26 |
Sunday, June 04, 2017, 06:52 : Source at TGHT / TBHT 580 / 290 A over night and outgassing while measuring mass 20. Both anode current andFC6 current increased whie vacuum decreased. Ramped TBHT up to 300 A. Anode current now 68 mA, FC6 0.2 nA, FC0 3 uA
Monday, June 05, 2017, 16:04: Starting cool down
Monday, June 05, 2017, 22:04: Source off. Stopped turbo pumps.
Tuesday, June 06, 2017, 07:28: RGA off.
Tuesday, June 06, 2017, 07:30: Venting |
Attachment 1: 20170605-Anode-Coil_CHT-sweep.xlsx
|
Attachment 2: TS-2017-06-02-16-21.rga
|
Attachment 3: SiC#36.docx
|
Attachment 4: OMEGA_OM-DAQPRO-5300_06-Jun-17_09.30.24.dlp
|
Attachment 5: ITW-TM2-SiC#36-HP-CTL-FEBIAD_Test_Stand.docx
|
Attachment 6: ER-580-300-30kV-m20.txt
|
value (Voltage offset 0.0000)
70.0000
1.3000
100.0000
29978.0220
21
21
./emit.dat
-0.1263 -0.0922 -0.0873 -0.0861 -0.0851 -0.0729 -0.0827 -0.0833 -0.0839 -0.0931 -0.0922 -0.0949 -0.0876 -0.0888 -0.0900 -0.0894 -0.0885 -0.0873 -0.0885 -0.0839 -0.0879
-0.0665 -0.0842 -0.0824 -0.0836 -0.0827 -0.0668 -0.0775 -0.0781 -0.0815 -0.0888 -0.0873 -0.0900 -0.0830 -0.0854 -0.0854 -0.0858 -0.0833 -0.0827 -0.0854 -0.0790 -0.0812
-0.0641 -0.0745 -0.0674 -0.0790 -0.0800 -0.0659 -0.0778 -0.0647 -0.0717 -0.0876 -0.0662 -0.0827 -0.0809 -0.0842 -0.0870 -0.0839 -0.0754 -0.0793 -0.0723 -0.0644 -0.0797
-0.0635 -0.0748 -0.0720 -0.0781 -0.0763 -0.0641 -0.0769 -0.0769 -0.0711 -0.0858 -0.0729 -0.0833 -0.0815 -0.0803 -0.0815 -0.0839 -0.0797 -0.0793 -0.0726 -0.0641 -0.0815
-0.0653 -0.0800 -0.0754 -0.0787 -0.0763 -0.0674 -0.0775 -0.0653 -0.0732 -0.0854 -0.0763 -0.0836 -0.0836 -0.0815 -0.0809 -0.0830 -0.0745 -0.0800 -0.0696 -0.0647 -0.0800
-0.0671 -0.0800 -0.0635 -0.0797 -0.0766 -0.0684 -0.0778 -0.0668 -0.0717 -0.0861 -0.0772 -0.0858 -0.0858 -0.0827 -0.0787 -0.0818 -0.0760 -0.0812 -0.0708 -0.0662 -0.0800
-0.0665 -0.0766 -0.0690 -0.0793 -0.0754 -0.0656 -0.0781 -0.0720 -0.0711 -0.0870 -0.0653 -0.0809 -0.0836 -0.0827 -0.0815 -0.0815 -0.0754 -0.0800 -0.0702 -0.0665 -0.0793
-0.0659 -0.0748 -0.0714 -0.0784 -0.0751 -0.0623 -0.0784 -0.0677 -0.0705 -0.0882 -0.0699 -0.0690 -0.0781 -0.0815 -0.0815 -0.0830 -0.0769 -0.0793 -0.0742 -0.0647 -0.0797
-0.0656 -0.0790 -0.0714 -0.0775 -0.0748 -0.0656 -0.0778 -0.0705 -0.0720 -0.0858 -0.0742 -0.0598 -0.0705 -0.0745 -0.0827 -0.0848 -0.0751 -0.0763 -0.0720 -0.0644 -0.0806
-0.0659 -0.0800 -0.0699 -0.0790 -0.0769 -0.0653 -0.0797 -0.0699 -0.0708 -0.0836 -0.0647 -0.0711 -0.0589 -0.0742 -0.0760 -0.0845 -0.0754 -0.0809 -0.0699 -0.0659 -0.0827
-0.0653 -0.0763 -0.0714 -0.0806 -0.0772 -0.0662 -0.0793 -0.0677 -0.0693 -0.0864 -0.0748 -0.0766 -0.0497 -0.0723 -0.0754 -0.0793 -0.0754 -0.0827 -0.0705 -0.0665 -0.0839
-0.0659 -0.0781 -0.0684 -0.0790 -0.0772 -0.0638 -0.0772 -0.0739 -0.0717 -0.0858 -0.0763 -0.0763 -0.0586 -0.0613 -0.0742 -0.0790 -0.0742 -0.0797 -0.0708 -0.0659 -0.0833
-0.0647 -0.0769 -0.0714 -0.0800 -0.0757 -0.0644 -0.0769 -0.0690 -0.0726 -0.0873 -0.0705 -0.0778 -0.0726 -0.0552 -0.0766 -0.0797 -0.0726 -0.0751 -0.0717 -0.0662 -0.0815
-0.0650 -0.0787 -0.0717 -0.0800 -0.0760 -0.0671 -0.0781 -0.0702 -0.0726 -0.0885 -0.0754 -0.0809 -0.0763 -0.0632 -0.0751 -0.0824 -0.0726 -0.0757 -0.0711 -0.0653 -0.0803
-0.0653 -0.0790 -0.0687 -0.0787 -0.0763 -0.0671 -0.0793 -0.0662 -0.0714 -0.0848 -0.0815 -0.0854 -0.0812 -0.0739 -0.0729 -0.0830 -0.0732 -0.0790 -0.0674 -0.0647 -0.0815
-0.0656 -0.0778 -0.0748 -0.0769 -0.0757 -0.0653 -0.0781 -0.0763 -0.0684 -0.0864 -0.0775 -0.0842 -0.0827 -0.0797 -0.0757 -0.0800 -0.0769 -0.0790 -0.0684 -0.0647 -0.0830
-0.0662 -0.0757 -0.0714 -0.0793 -0.0775 -0.0635 -0.0769 -0.0681 -0.0693 -0.0885 -0.0766 -0.0818 -0.0824 -0.0812 -0.0778 -0.0818 -0.0769 -0.0787 -0.0690 -0.0644 -0.0815
-0.0638 -0.0763 -0.0748 -0.0790 -0.0772 -0.0635 -0.0754 -0.0711 -0.0714 -0.0861 -0.0748 -0.0836 -0.0830 -0.0815 -0.0790 -0.0848 -0.0751 -0.0766 -0.0690 -0.0641 -0.0797
-0.0626 -0.0751 -0.0708 -0.0787 -0.0763 -0.0647 -0.0763 -0.0696 -0.0708 -0.0854 -0.0729 -0.0842 -0.0854 -0.0818 -0.0803 -0.0830 -0.0763 -0.0803 -0.0681 -0.0644 -0.0784
-0.0629 -0.0748 -0.0674 -0.0784 -0.0751 -0.0659 -0.0778 -0.0705 -0.0699 -0.0845 -0.0757 -0.0845 -0.0821 -0.0803 -0.0812 -0.0815 -0.0729 -0.0803 -0.0690 -0.0659 -0.0781
-0.0668 -0.0739 -0.0693 -0.0766 -0.0772 -0.0635 -0.0769 -0.0656 -0.0690 -0.0848 -0.0754 -0.0836 -0.0815 -0.0812 -0.0797 -0.0803 -0.0745 -0.0790 -0.0699 -0.0641 -0.0812
|
Attachment 7: CHT-290-AV-200-CI-70.txt
|
value (Voltage offset 0.0000)
80.0000
0.7000
100.0000
29978.0220
21
21
./emit.dat
-0.1340 -0.0769 -0.0870 -0.0967 -0.0836 -0.0986 -0.0946 -0.0848 -0.0851 -0.0943 -0.0946 -0.0870 -0.0821 -0.0845 -0.0885 -0.0928 -0.0870 -0.0888 -0.0955 -0.0903 -0.0934
-0.0729 -0.0699 -0.0809 -0.0931 -0.0793 -0.0937 -0.0885 -0.0775 -0.0793 -0.0888 -0.0912 -0.0815 -0.0775 -0.0803 -0.0818 -0.0879 -0.0812 -0.0821 -0.0900 -0.0873 -0.0888
-0.0745 -0.0656 -0.0717 -0.0760 -0.0729 -0.0888 -0.0854 -0.0763 -0.0726 -0.0821 -0.0867 -0.0693 -0.0711 -0.0742 -0.0815 -0.0882 -0.0793 -0.0806 -0.0821 -0.0906 -0.0729
-0.0766 -0.0668 -0.0681 -0.0824 -0.0739 -0.0830 -0.0870 -0.0781 -0.0757 -0.0827 -0.0790 -0.0696 -0.0705 -0.0656 -0.0812 -0.0867 -0.0732 -0.0827 -0.0677 -0.0702 -0.0687
-0.0760 -0.0674 -0.0684 -0.0839 -0.0729 -0.0851 -0.0885 -0.0781 -0.0781 -0.0842 -0.0800 -0.0702 -0.0708 -0.0671 -0.0815 -0.0873 -0.0775 -0.0821 -0.0696 -0.0668 -0.0665
-0.0735 -0.0690 -0.0687 -0.0708 -0.0754 -0.0854 -0.0879 -0.0784 -0.0797 -0.0848 -0.0812 -0.0775 -0.0726 -0.0723 -0.0800 -0.0867 -0.0757 -0.0824 -0.0729 -0.0674 -0.0677
-0.0739 -0.0677 -0.0687 -0.0665 -0.0693 -0.0790 -0.0836 -0.0757 -0.0815 -0.0851 -0.0800 -0.0797 -0.0684 -0.0729 -0.0800 -0.0851 -0.0735 -0.0827 -0.0723 -0.0674 -0.0677
-0.0742 -0.0671 -0.0659 -0.0702 -0.0763 -0.0732 -0.0714 -0.0589 -0.0650 -0.0851 -0.0778 -0.0702 -0.0687 -0.0674 -0.0806 -0.0864 -0.0702 -0.0821 -0.0708 -0.0681 -0.0684
-0.0723 -0.0687 -0.0674 -0.0815 -0.0787 -0.0763 -0.0681 -0.0464 -0.0476 -0.0641 -0.0693 -0.0656 -0.0671 -0.0702 -0.0815 -0.0867 -0.0742 -0.0824 -0.0705 -0.0677 -0.0705
-0.0708 -0.0671 -0.0656 -0.0827 -0.0787 -0.0815 -0.0757 -0.0458 -0.0455 -0.0583 -0.0586 -0.0589 -0.0629 -0.0702 -0.0818 -0.0876 -0.0769 -0.0827 -0.0699 -0.0681 -0.0687
-0.0729 -0.0638 -0.0644 -0.0769 -0.0806 -0.0800 -0.0790 -0.0558 -0.0357 -0.0494 -0.0543 -0.0562 -0.0632 -0.0607 -0.0775 -0.0873 -0.0742 -0.0839 -0.0732 -0.0677 -0.0665
-0.0732 -0.0665 -0.0638 -0.0720 -0.0745 -0.0790 -0.0797 -0.0604 -0.0446 -0.0424 -0.0485 -0.0613 -0.0623 -0.0668 -0.0732 -0.0781 -0.0708 -0.0830 -0.0674 -0.0674 -0.0659
-0.0726 -0.0656 -0.0668 -0.0833 -0.0739 -0.0754 -0.0793 -0.0644 -0.0604 -0.0519 -0.0421 -0.0504 -0.0623 -0.0671 -0.0754 -0.0809 -0.0705 -0.0729 -0.0674 -0.0690 -0.0668
-0.0732 -0.0693 -0.0677 -0.0839 -0.0790 -0.0827 -0.0818 -0.0668 -0.0671 -0.0632 -0.0458 -0.0455 -0.0574 -0.0665 -0.0809 -0.0854 -0.0708 -0.0778 -0.0668 -0.0632 -0.0687
-0.0742 -0.0699 -0.0699 -0.0845 -0.0821 -0.0842 -0.0888 -0.0760 -0.0717 -0.0726 -0.0623 -0.0479 -0.0549 -0.0681 -0.0812 -0.0873 -0.0720 -0.0806 -0.0681 -0.0644 -0.0650
-0.0735 -0.0677 -0.0690 -0.0781 -0.0836 -0.0873 -0.0879 -0.0766 -0.0818 -0.0830 -0.0732 -0.0580 -0.0610 -0.0674 -0.0800 -0.0873 -0.0739 -0.0824 -0.0739 -0.0650 -0.0644
-0.0705 -0.0659 -0.0681 -0.0818 -0.0815 -0.0851 -0.0870 -0.0757 -0.0797 -0.0854 -0.0763 -0.0726 -0.0681 -0.0677 -0.0784 -0.0851 -0.0717 -0.0821 -0.0681 -0.0668 -0.0659
-0.0726 -0.0647 -0.0659 -0.0833 -0.0757 -0.0812 -0.0858 -0.0754 -0.0793 -0.0861 -0.0763 -0.0674 -0.0687 -0.0720 -0.0797 -0.0861 -0.0726 -0.0803 -0.0681 -0.0684 -0.0681
-0.0742 -0.0677 -0.0681 -0.0842 -0.0726 -0.0833 -0.0854 -0.0766 -0.0800 -0.0824 -0.0766 -0.0699 -0.0681 -0.0705 -0.0836 -0.0873 -0.0748 -0.0812 -0.0705 -0.0696 -0.0681
-0.0735 -0.0671 -0.0702 -0.0848 -0.0735 -0.0830 -0.0861 -0.0775 -0.0821 -0.0839 -0.0790 -0.0717 -0.0720 -0.0693 -0.0800 -0.0876 -0.0748 -0.0815 -0.0677 -0.0674 -0.0650
-0.0732 -0.0659 -0.0681 -0.0833 -0.0797 -0.0848 -0.0879 -0.0781 -0.0797 -0.0830 -0.0769 -0.0729 -0.0702 -0.0711 -0.0793 -0.0864 -0.0742 -0.0803 -0.0702 -0.0656 -0.0650
|
Attachment 8: 20170605_1029_emit_A40.txt
|
value (Voltage offset 0.0000)
80.0000
0.7000
100.0000
29978.0220
21
21
./emit.dat
-0.1291 -0.0717 -0.0934 -0.0940 -0.0946 -0.0952 -0.0955 -0.0934 -0.0937 -0.0958 -0.0946 -0.0964 -0.0912 -0.0967 -0.0943 -0.0952 -0.0961 -0.0946 -0.0937 -0.0949 -0.0940
-0.0696 -0.0690 -0.0876 -0.0916 -0.0894 -0.0916 -0.0916 -0.0870 -0.0894 -0.0919 -0.0903 -0.0919 -0.0879 -0.0909 -0.0919 -0.0900 -0.0888 -0.0888 -0.0876 -0.0912 -0.0906
-0.0668 -0.0735 -0.0912 -0.0806 -0.0806 -0.0891 -0.0909 -0.0864 -0.0763 -0.0897 -0.0845 -0.0702 -0.0763 -0.0867 -0.0919 -0.0894 -0.0888 -0.0900 -0.0848 -0.0803 -0.0729
-0.0656 -0.0674 -0.0702 -0.0580 -0.0842 -0.0882 -0.0903 -0.0870 -0.0824 -0.0870 -0.0821 -0.0644 -0.0626 -0.0812 -0.0885 -0.0909 -0.0879 -0.0894 -0.0812 -0.0665 -0.0681
-0.0681 -0.0653 -0.0818 -0.0668 -0.0830 -0.0864 -0.0888 -0.0903 -0.0854 -0.0864 -0.0854 -0.0742 -0.0726 -0.0867 -0.0897 -0.0919 -0.0876 -0.0906 -0.0848 -0.0677 -0.0668
-0.0681 -0.0681 -0.0858 -0.0687 -0.0824 -0.0879 -0.0900 -0.0876 -0.0897 -0.0873 -0.0867 -0.0705 -0.0790 -0.0903 -0.0922 -0.0928 -0.0882 -0.0861 -0.0827 -0.0693 -0.0677
-0.0684 -0.0687 -0.0854 -0.0684 -0.0745 -0.0775 -0.0809 -0.0858 -0.0858 -0.0888 -0.0885 -0.0696 -0.0717 -0.0885 -0.0906 -0.0885 -0.0861 -0.0873 -0.0818 -0.0659 -0.0690
-0.0677 -0.0693 -0.0842 -0.0656 -0.0790 -0.0601 -0.0461 -0.0449 -0.0558 -0.0833 -0.0851 -0.0684 -0.0699 -0.0836 -0.0894 -0.0885 -0.0867 -0.0879 -0.0815 -0.0662 -0.0681
-0.0641 -0.0659 -0.0809 -0.0668 -0.0842 -0.0674 -0.0397 0.0027 -0.0125 -0.0400 -0.0626 -0.0650 -0.0751 -0.0879 -0.0912 -0.0903 -0.0879 -0.0897 -0.0842 -0.0690 -0.0681
-0.0635 -0.0616 -0.0793 -0.0635 -0.0803 -0.0748 -0.0580 0.0098 0.0266 -0.0250 -0.0439 -0.0363 -0.0549 -0.0885 -0.0912 -0.0922 -0.0870 -0.0909 -0.0842 -0.0681 -0.0668
-0.0687 -0.0613 -0.0809 -0.0610 -0.0748 -0.0757 -0.0656 -0.0302 0.0601 0.0275 -0.0293 -0.0360 -0.0531 -0.0656 -0.0800 -0.0888 -0.0888 -0.0867 -0.0839 -0.0665 -0.0656
-0.0705 -0.0644 -0.0815 -0.0598 -0.0766 -0.0772 -0.0720 -0.0513 -0.0058 0.0369 0.0107 -0.0250 -0.0519 -0.0705 -0.0739 -0.0705 -0.0793 -0.0842 -0.0818 -0.0668 -0.0668
-0.0696 -0.0650 -0.0818 -0.0693 -0.0800 -0.0763 -0.0775 -0.0665 -0.0424 0.0027 0.0269 -0.0131 -0.0500 -0.0720 -0.0772 -0.0772 -0.0766 -0.0757 -0.0784 -0.0665 -0.0684
-0.0693 -0.0674 -0.0827 -0.0702 -0.0894 -0.0864 -0.0800 -0.0708 -0.0598 -0.0400 -0.0049 0.0021 -0.0476 -0.0732 -0.0800 -0.0848 -0.0790 -0.0812 -0.0745 -0.0586 -0.0665
-0.0696 -0.0668 -0.0854 -0.0726 -0.0876 -0.0879 -0.0894 -0.0867 -0.0769 -0.0626 -0.0494 -0.0250 -0.0400 -0.0742 -0.0867 -0.0894 -0.0870 -0.0833 -0.0793 -0.0623 -0.0592
-0.0684 -0.0693 -0.0827 -0.0677 -0.0842 -0.0848 -0.0864 -0.0891 -0.0845 -0.0848 -0.0729 -0.0461 -0.0473 -0.0671 -0.0845 -0.0900 -0.0848 -0.0858 -0.0833 -0.0650 -0.0626
-0.0696 -0.0699 -0.0830 -0.0668 -0.0851 -0.0848 -0.0876 -0.0879 -0.0824 -0.0897 -0.0812 -0.0647 -0.0638 -0.0757 -0.0815 -0.0867 -0.0876 -0.0882 -0.0818 -0.0668 -0.0659
-0.0702 -0.0668 -0.0839 -0.0690 -0.0842 -0.0870 -0.0897 -0.0845 -0.0845 -0.0851 -0.0812 -0.0681 -0.0717 -0.0854 -0.0854 -0.0861 -0.0842 -0.0867 -0.0827 -0.0687 -0.0684
-0.0687 -0.0668 -0.0854 -0.0717 -0.0885 -0.0891 -0.0882 -0.0848 -0.0858 -0.0854 -0.0839 -0.0674 -0.0778 -0.0867 -0.0891 -0.0897 -0.0858 -0.0873 -0.0848 -0.0677 -0.0668
-0.0687 -0.0647 -0.0864 -0.0674 -0.0854 -0.0897 -0.0888 -0.0873 -0.0867 -0.0885 -0.0839 -0.0684 -0.0739 -0.0879 -0.0897 -0.0900 -0.0903 -0.0888 -0.0833 -0.0668 -0.0656
-0.0668 -0.0644 -0.0842 -0.0671 -0.0842 -0.0888 -0.0876 -0.0861 -0.0848 -0.0842 -0.0842 -0.0662 -0.0687 -0.0873 -0.0916 -0.0897 -0.0861 -0.0845 -0.0824 -0.0671 -0.0653
|
Attachment 9: 20170605_1024_emit_A40.txt
|
value (Voltage offset 0.0000)
70.0000
1.3000
100.0000
29978.0220
21
21
./emit.dat
-0.1505 -0.0943 -0.0912 -0.0958 -0.0925 -0.0778 -0.0784 -0.0763 -0.0766 -0.0906 -0.0879 -0.0903 -0.0922 -0.0906 -0.0937 -0.0934 -0.0946 -0.0922 -0.0952 -0.0931 -0.0955
-0.0595 -0.0888 -0.0842 -0.0906 -0.0848 -0.0705 -0.0723 -0.0717 -0.0729 -0.0833 -0.0830 -0.0861 -0.0842 -0.0845 -0.0903 -0.0891 -0.0903 -0.0854 -0.0906 -0.0867 -0.0903
-0.0714 -0.0815 -0.0797 -0.0873 -0.0888 -0.0735 -0.0708 -0.0739 -0.0693 -0.0784 -0.0821 -0.0827 -0.0861 -0.0800 -0.0836 -0.0870 -0.0781 -0.0876 -0.0806 -0.0659 -0.0897
-0.0699 -0.0769 -0.0534 -0.0851 -0.0848 -0.0598 -0.0711 -0.0659 -0.0653 -0.0809 -0.0751 -0.0781 -0.0812 -0.0800 -0.0842 -0.0882 -0.0803 -0.0897 -0.0790 -0.0684 -0.0903
-0.0732 -0.0839 -0.0644 -0.0836 -0.0885 -0.0671 -0.0690 -0.0815 -0.0677 -0.0815 -0.0766 -0.0815 -0.0800 -0.0848 -0.0821 -0.0864 -0.0742 -0.0903 -0.0812 -0.0668 -0.0912
-0.0729 -0.0891 -0.0681 -0.0864 -0.0864 -0.0702 -0.0696 -0.0769 -0.0690 -0.0800 -0.0726 -0.0815 -0.0861 -0.0812 -0.0833 -0.0839 -0.0772 -0.0885 -0.0824 -0.0684 -0.0906
-0.0732 -0.0861 -0.0732 -0.0873 -0.0876 -0.0674 -0.0690 -0.0717 -0.0681 -0.0793 -0.0607 -0.0714 -0.0861 -0.0809 -0.0830 -0.0876 -0.0800 -0.0876 -0.0800 -0.0671 -0.0912
-0.0739 -0.0833 -0.0708 -0.0885 -0.0870 -0.0604 -0.0684 -0.0699 -0.0647 -0.0800 -0.0620 -0.0351 -0.0598 -0.0793 -0.0854 -0.0897 -0.0797 -0.0885 -0.0800 -0.0656 -0.0906
-0.0754 -0.0858 -0.0653 -0.0882 -0.0903 -0.0671 -0.0684 -0.0644 -0.0638 -0.0784 -0.0674 -0.0204 -0.0140 -0.0558 -0.0824 -0.0876 -0.0781 -0.0888 -0.0806 -0.0659 -0.0912
-0.0763 -0.0867 -0.0668 -0.0897 -0.0894 -0.0687 -0.0684 -0.0735 -0.0626 -0.0751 -0.0674 -0.0418 0.0314 -0.0415 -0.0555 -0.0851 -0.0757 -0.0900 -0.0800 -0.0720 -0.0900
-0.0754 -0.0867 -0.0705 -0.0900 -0.0864 -0.0677 -0.0693 -0.0668 -0.0659 -0.0735 -0.0681 -0.0507 0.0629 -0.0208 -0.0577 -0.0656 -0.0769 -0.0873 -0.0812 -0.0714 -0.0894
-0.0745 -0.0839 -0.0693 -0.0882 -0.0864 -0.0656 -0.0702 -0.0745 -0.0681 -0.0723 -0.0653 -0.0601 -0.0052 0.0259 -0.0586 -0.0677 -0.0641 -0.0891 -0.0827 -0.0656 -0.0903
-0.0763 -0.0809 -0.0644 -0.0861 -0.0867 -0.0665 -0.0699 -0.0717 -0.0632 -0.0797 -0.0644 -0.0656 -0.0400 0.0293 -0.0558 -0.0720 -0.0684 -0.0781 -0.0772 -0.0662 -0.0894
-0.0793 -0.0827 -0.0653 -0.0882 -0.0864 -0.0693 -0.0711 -0.0668 -0.0656 -0.0809 -0.0757 -0.0681 -0.0577 -0.0064 -0.0433 -0.0797 -0.0705 -0.0839 -0.0708 -0.0671 -0.0906
-0.0763 -0.0873 -0.0687 -0.0882 -0.0876 -0.0693 -0.0702 -0.0806 -0.0665 -0.0803 -0.0766 -0.0812 -0.0735 -0.0455 -0.0415 -0.0790 -0.0732 -0.0848 -0.0739 -0.0656 -0.0879
-0.0739 -0.0848 -0.0690 -0.0858 -0.0864 -0.0650 -0.0702 -0.0702 -0.0696 -0.0797 -0.0726 -0.0797 -0.0848 -0.0684 -0.0562 -0.0739 -0.0745 -0.0867 -0.0760 -0.0620 -0.0864
-0.0748 -0.0833 -0.0665 -0.0876 -0.0833 -0.0644 -0.0708 -0.0693 -0.0687 -0.0769 -0.0751 -0.0803 -0.0845 -0.0793 -0.0797 -0.0784 -0.0775 -0.0879 -0.0812 -0.0623 -0.0873
-0.0760 -0.0839 -0.0674 -0.0885 -0.0851 -0.0668 -0.0729 -0.0742 -0.0662 -0.0781 -0.0739 -0.0797 -0.0815 -0.0800 -0.0833 -0.0858 -0.0769 -0.0879 -0.0803 -0.0681 -0.0885
-0.0766 -0.0815 -0.0687 -0.0876 -0.0870 -0.0699 -0.0702 -0.0717 -0.0662 -0.0784 -0.0757 -0.0797 -0.0815 -0.0787 -0.0806 -0.0851 -0.0775 -0.0888 -0.0781 -0.0693 -0.0870
-0.0751 -0.0824 -0.0702 -0.0888 -0.0867 -0.0671 -0.0677 -0.0702 -0.0665 -0.0797 -0.0742 -0.0790 -0.0815 -0.0812 -0.0824 -0.0839 -0.0775 -0.0885 -0.0787 -0.0677 -0.0879
-0.0742 -0.0842 -0.0674 -0.0827 -0.0861 -0.0653 -0.0684 -0.0705 -0.0668 -0.0803 -0.0732 -0.0787 -0.0821 -0.0784 -0.0836 -0.0858 -0.0763 -0.0879 -0.0793 -0.0671 -0.0873
|
590
|
Tuesday, June 06, 2017, 09:22 |
Aaron Schmidt | | | | | | | | Pump down empty chamber | Tuesday, June 06, 2017, 09:21: roughing.
Friday, June 09, 2017, 08:50: Ion gauge off. Turbo pumps off.
Friday, June 09, 2017, 10:46: Venting. |
591
|
Wednesday, June 07, 2017, 12:49 |
Aaron Schmidt | | | | | | | | Gas bottles | Gas bottles for FEBIAD testing were exchanged yesterday around 1:30. One Neon & one Argon bottle were removed.
Two Neon bottles were added. |
593
|
Friday, June 16, 2017, 11:23 |
Aaron Schmidt | | | | | | | | Pump down empty chamber. | Friday, June 16, 2017, 11:22: roughing.
Friday, June 16, 2017, 14:28: Turbo pumps on
Friday, June 30, 2017, 10:37: Ion gauge, turbos off.
Friday, June 30, 2017, 13:01: Venting. |
598
|
Monday, July 17, 2017, 09:58 |
Aaron Schmidt | | HP-SIS | | | 42218-8 | 42738-1 | | Target cleaning test (Long) HP-SIS CC Clean | Target Test (Fully Cleaned vs Crystal Clean only).
For all tests:
-Start Turbo pumps & Ion gauge as soon as available on ISAC TEST STAND VACUUM Screen.
- Ensure previous test turbos are off by 8:15 and started venting by 9:15am to meet timeline.
-Start Roughing by 10:10am +/- 1 minute.
-TGHT / TBHT ramping starts @ 8:30am. 2A per min to 580A / 200A
ALL START TIMES MUST BE CONSISTENT.
***Pre-outgassed*** Heat Shield W.O# 42738-1: Includes insulators, new Al grounded 9-pin, bracket, & gripper arms. Blank/Plate. No source cup/EE.
HP-SIS Target # 42218-8: Crystal Clean only.
Monday, July 24, 2017, 09:46: HS removed from test stand. Exchange target.
Monday, July 24, 2017, 10:08: Target # 42218-8 placed into test stand. Door open for 22 minutes.
Monday, July 24, 2017, 10:10: Roughing.
Monday, July 24, 2017, 10:10: Doors sealed for roughing.
Monday, July 24, 2017, 10:11: BV1B OPEN. Opened @ 306T.
Monday, July 24, 2017, 10:29: Both Turbo pumps started.
Monday, July 24, 2017, 10:34: Ion gauge on. TP1B @ speed 42 KRPM.
Monday, July 24, 2017, 10:38: TP1A @ speed 38 KRPM.
Monday, July 24, 2017, 10:40: RGA on. Vacuum @ 1.51E-05T.
Monday, July 24, 2017, 15:03: Vacuum @ 6.14e-07T
Tuesday, July 25, 2017, 08:02: Water lines opened. No response on RGA. Vacuum stable @ 1.97E-07T.
Tuesday, July 25, 2017, 08:05: Power/Sources on.
Tuesday, July 25, 2017, 08:23: Anode increased to 5, 10, 25, 50 V. Ok @ 0.000mA
Device |
Temp
[C] |
Flow
[lpm] |
HS + MSP |
27.3 |
3.77 |
TBHT |
27.3 |
3.02 |
COIL + EE |
27.1 |
4.91 |
TGHT |
27.3 |
5.53 |
Tuesday, July 25, 2017, 08:30: Auto ramping TGHT / TBHT to 580 / 200 A @ 2A per min.
Tuesday, July 25, 2017, 09:00: Open back power supply panel. Using multimeter, 9-pin ground connection verified. Panel closed.
10:45: Check. Vacuum @ 2E-06T.
11:45: Check. Vacuum @ 3.33E-07T.
13:30: Check. Vacuum @ 2.78E-07T.
Device |
Temp
[C] |
Flow
[lpm] |
HS + MSP |
33.5 |
3.78 |
TBHT |
28.1 |
3.03 |
COIL + EE |
27.2 |
4.92 |
TGHT |
29.4
|
4.48 |
Tuesday, July 25, 2017, 14:27: Open back power supply panel. Using multimeter, 9-pin ground connection verified. Panel closed
Wednesday, July 26, 2017, 08:15: Check. Vacuum @ 2.60E-07T.
Device |
Temp
[C] |
Flow
[lpm] |
HS + MSP |
33.5 |
3.78 |
TBHT |
27.6 |
2.99 |
COIL + EE |
27.2 |
4.06 |
TGHT |
29.4
|
5.52 |
Wednesday, July 26, 2017, 15:00: Auto-Cooling @ 2A per min. Check. Vacuum @ @2.43e-07T
Thursday, July 27, 2017, 07:20: Check. Vacuum @ 1.44e-07T
Thursday, July 27, 2017, 07:22: Power/sources off.
Thursday, July 27, 2017, 07:24: Waterlines purged.
Thursday, July 27, 2017, 07:26: RGA off.
Thursday, July 27, 2017, 07:27: Ion gauge, Turbos off
Thursday, July 27, 2017, 09:13: Venting. |
Attachment 1: HP-SIS_CC_Clean_(Long).docx
|
Attachment 2: OMEGA_OM-DAQPRO-5300_27-Jul-17_10.25.04.dlp
|
Attachment 3: TS-2017-07-24-10-40.rga
|
599
|
Monday, July 17, 2017, 10:04 |
Aaron Schmidt | | HP-SIS | | | 42218-10 | 42738-1 | | Target cleaning test HP-SIS Full Clean | Target Test (Fully Cleaned vs Crystal Clean only).
For all tests:
-Start Turbo pumps & Ion gauge as soon as available on ISAC TEST STAND VACUUM Screen.
- Ensure previous test turbos are off by 8:15 and started venting by 9:15am to meet timeline.
-Start Roughing by 10:10am +/- 1 minute.
-TGHT / TBHT ramping starts @ 8:30am. 2A per min to 580A / 200A
ALL START TIMES MUST BE CONSISTENT.
***Pre-outgassed*** Heat Shield W.O# 42738-1: Includes insulators, new Al grounded 9-pin, bracket, & gripper arms. Blank/Plate. No source cup/EE.
HP-SIS Target # 42218-10: Full Clean. Crystal Clear, Acetone, & Methanol used.
Thursday, July 27, 2017, 09:49: HS removed from test stand. Exchange target.
Thursday, July 27, 2017, 10:07: Target # 42218-10 placed into test stand. Door open for 20 minutes.
Thursday, July 27, 2017, 10:10: Roughing.
Thursday, July 27, 2017, 10:10: Doors sealed for roughing.
Thursday, July 27, 2017, 10:13 BV1B OPEN. Opened @ 230T.
Thursday, July 27, 2017, 10:29: Both Turbo pumps started.
Thursday, July 27, 2017, 10:34: Ion gauge on. TP1B @ speed 42 KRPM.
Thursday, July 27, 2017, 10:37: TP1A @ speed 38 KRPM.
Thursday, July 27, 2017, 10:40: RGA on. Vacuum @ 1.42T.
Thursday, July 27, 2017,15:00: Check. Vacuum @ 5.51e-07T.
Thursday, July 27, 2017, 15:02: Waterlines opened. No response on RGA. Vacuum @ 5.42e-07T
Thursday, July 27, 2017, 15:05: Power on.
Friday, July 28, 2017, 08:30: Ramping started
Monday, July 31, 2017, 07:56: Ramping down
Monday, July 31, 2017, 14:25: Power supplies off. RGA off.
Tuesday, August 15, 2017, 06:48: Ion gauge, Turbo pumps off.
Tuesday, August 15, 2017, 06:50: power off. Waterlines purged.
Tuesday, August 15, 2017, 07:55: Venting. |
Attachment 1: HP-SIS_Full_Clean_(Short).docx
|
Attachment 2: TS-2017-07-27-10-40.rga
|
606
|
Monday, September 25, 2017, 14:10 |
Aaron Schmidt | | | | | | | | Pump down empty chamber | Monday, September 25, 2017, 14:10: Roughing.
Wednesday, September 27, 2017, 08:23: Turbo pumps on
Friday, October 06, 2017, 09:04: Ion gauge off. Turbos off.
Friday, October 06, 2017, 11:17: Venting. |
608
|
Tuesday, October 10, 2017, 13:10 |
Aaron Schmidt | | | | | | | | Gas bottles | Tuesday, October 10, 2017, 09:30: Install/swap gas bottles. Elog.
Removed smallest Neon leak. Neon Bottle Serial #11231. Leak rate calibrated @ 1.59e-07 atm*CC/sec (02/09/2016)
In use:
Neon Bottle Serial #09572. Leak rate calibrated @ 1.82e-06 atm*CC/sec (02/09/2016)
Argon Bottle Serial #09937. Leak rate calibrated @ 1.35 x10-6 Atm-CC/sec (08/06/2003)
Tuesday, October 10, 2017, 10:12: Gas bottles opened. Pump not on? Vacuum spiked into e-04T. All closed. Await vacuum stabilization.
Tuesday, October 10, 2017, 10:36: Power on. Pump on Gas bottles opened. Await vacuum stabilization.
pump off. |
612
|
Tuesday, October 24, 2017, 11:38 |
Anders Mjos | | | | | | | | FEBIAD coil magnetic field measurment | with Fernando
Tuesday, October 24, 2017: Testing setup with triple coil
Wednesday, October 25, 2017: Field mapping at 70 A and current/field measurements on triple coil. |
Attachment 1: FEBIAD_Coil_Field_Measurement_2017-10-25.xlsx
|
Attachment 2: 171025-First-Run.xlsx
|
619
|
Thursday, December 21, 2017, 15:12 |
Anders Mjos | | | | | | | | Powered down devices | Powered down vacuum gauge and turbo pump controllers |
629
|
Wednesday, February 07, 2018, 08:46 |
Aaron Schmidt | | | | | | | | BIAS Power supply installation | Wednesday, February 07, 2018, 08:40: A 75 kV Glassman power supply was installed in the rack for use in further HV testing.
-The 75kV power supply is linked into the keyed interlock system. The key & switch labelled BIAS/EZL will unlock it.
-The PS is currently not connected to the epics controls and can only be adjusted manually.
-The old Glassman supply is disconnected and removed from the cage. |
Attachment 1: BIAS_PS_off_top_switch.jpg
|
|
Attachment 2: BIAS_PS_70kV_rear_bottom.jpg
|
|
Attachment 3: BIAS_PS_70kV_Front_bottom.jpg
|
|
631
|
Thursday, February 08, 2018, 16:54 |
Carla Babcock | | | | | | | | EZL strange behaviour | Thursday, February 08, 2018, 16:54
Testing the HV bias I found that the einzel lens was behaving strangely. When I tried to put it higher than 1kV, the current would start spiking from 12uA to > 100uA. The voltage would jump around quite a bit as well (+/- 100V). Everything seems the way it was before, except the EZL power supply is still connected in parallel with the old bias power supply, which is no longer powered. Maybe one of the transorbs connecting line and neutral on the bias side is fried? I will unhook the connection to the old PSU and try again.
|
632
|
Friday, February 09, 2018, 08:57 |
Carla Babcock | | | | | | | | TSGBIASSAFETY ok interlock | Friday, February 09, 2018, 08:25 Disconnected the AC power chain from the old bias supply but now cannot turn on the new bias supply in EPICS because the "TSGBIASSAFETY ok" interlock is tripped. No idea what this means - maybe it checks for AC power?
Friday, February 09, 2018, 08:48 Reconnected power to old bias supply, does not fix problem. Talked to Mike, he thinks it is PLC related, so will call Gelo later.
Friday, February 09, 2018, 11:38 TSGBIASSAFETY ok interlock problem seems to have solved itself, it now appears to be working fine. Will turn off power for now and continue tests on Tuesday. (note: turns out Mike told Dave about the problem and he solved it. No one knows what this interlock is for, but it used to be reset using the Global Reset button and now the RST button for the power supply should also reset it.) |
633
|
Tuesday, February 13, 2018, 12:17 |
Carla Babcock | | | | | | | | Ramping up bias to 60kV with conditioning station supply | Ramped up to 60kV with the new power supply, same as what we did last time with the standard test stand bias supply (see entry #627 ). Much more instability on the bias current readout (see attached screen shot), develops around 54kV. As well, the old supply read out 37uA at 60kV while the new supply reads out ~85uA. This could just be an EPICS read back issue though. |
Attachment 1: vacuumbias_13022018.PNG
|
|
634
|
Tuesday, February 13, 2018, 16:47 |
Carla Babcock | | | | | | | | Ramping to 63kV - some sparks | Sparks at 62kV on the bias.
Turned it down, turned it back up and got a spark at 60kV.
Now up to 63kV, no sparks so far (5 mins). Left EE @ -3100V and EZL @ 28.5kV
There is the sound of a low level continuous discharge, like HV power lines, and a very strong ozone smell coming from the HV duct that sticks into the cage and carries the cables from the HV rack. Also seems to be present near the EE insulating standoff. Can't see anything though. Maybe just moisture in the air? Starts at 55kV on the bias, does not change with EE voltage.
Turned EZL up to 29kV, bias stable at 63kV for 11mins.
Sparks at 63.6kV in the EE spark gap, EE @ -3.1kV. |
635
|
Friday, February 16, 2018, 15:21 |
Carla Babcock | | | | | | | | Cleaned HV cage - trying bias again | I vacuumed inside the HV cage, though it has many small areas that are difficult to access so I am not sure how great a job I did.
Turned the bias up and again at 55kV I hear small sparks near the end of the HV duct that brings the cables from the rack. Cannot see anything. If it is really sparking where it sounds like sparking, it must be from the edge of the duct to the faraday cage.
Changing the EZL voltage and the EE voltage has no effect on where it starts sparking. |
636
|
Monday, February 19, 2018, 08:30 |
Carla Babcock | | | | | | | | TMSTP6 off | Found TMSTP6 off, restarted it, seems fine now (drawing 0.8A) |
|