Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Test-Stand, Page 46 of 53  Not logged in ELOG logo
  ID Date Authordown Target/No.# Source Station Module Target Oven W.O# Heat Shield W.O# Status Subject
  800   Monday, July 13, 2020, 14:52 Aaron Schmidt LP-FEBIAD  41790-943515-2 UCx HS conditioning.

Broken LP-FEBIAD used to out gas.

Monday, July 13, 2020, 14:52: Roughing.

Monday, July 13, 2020, 15:29: Turbo pumps on. 

Monday, July 13, 2020, 15:34: Ion gauge on.


Tuesday, July 14, 2020, 06:44: Waterlines opened.

Tuesday, July 14, 2020, 06:47: Power / sources on.

Tuesday, July 14, 2020, 06:49: Auto-ramping TGHT to 580 A @ 2 A per min.

Tuesday, July 14, 2020, 14:15: Vacuum @ 2.59e-06T 


Friday, July 17, 2020, 10:54: Auto-cooling @ 1 A per min. 


Monday, July 20, 2020, 06:51: Power /  sources off.

Monday, July 20, 2020, 06:52: Ion gauge / Turbo pumps off.

Monday, July 20, 2020, 06:53: Re-attached N bottle / regulator for purging.

Monday, July 20, 2020, 06:57: Waterlines Purged. N bottle @ 1300 PSI.

  801   Monday, July 20, 2020, 11:40 Aaron Schmidt(Empty-Test)   44160-143822-2In progressConditioning Test P2N

Salts added: 

Cs - 15 uL

Li - 10 uL

Na - 10 uL

Rb - 10 uL

K - 5 uL

Empty target in use. Mirror installed inside to look at the target through the top cooling opening.

Monday, July 20, 2020, 14:36: Roughing. Assistance req'd to close the doors.

Monday, July 20, 2020, 15:12: Turbo pumps on.

Monday, July 20, 2020, 15:17: Ion gauge on.

Monday, July 20, 2020, 15:26: TP1A tripped.

Monday, July 20, 2020, 16:00: Continued backing trips. Await pump down.

Monday, July 20, 2020, 16:29: Attempt Bypass.

Monday, July 20, 2020, 16:32: Trip on TMS:TP2? Odd. Restarted quick.

Monday, July 20, 2020, 16:34: TSG:TP1A & TSG:TP1B up to speed. Ion gauge on. Pumping down.


See: https://elog.triumf.ca/TIS/Test-Stand/802 for wiring spec. TGHT / TBHT (on coil) connected.

Tuesday, July 21, 2020, 07:16: Water lines Opened. No response on vacuum. Ok @ 2.13e-06T. 

Tuesday, July 21, 2020, 08:27: Ion gauge & Turbo pumps off. One more target / electrical check is required.

Tuesday, July 21, 2020, 09:50: Venting.

Tuesday, July 21, 2020, 10:19

Extech measurements (µOhm):

TGHT Left leg Ta-Cu: 205, 215, 212, 201.

TGHT Right leg Ta-Cu: 287, 295, 275, 292.

TGHT Ta legs: 596, 606, 597, 598.

TBHT A: 1470, 1471.

TBHT B: 1469, 1469.

Tuesday, July 21, 2020, 10:36: Roughing.

Tuesday, July 21, 2020, 13:06: Turbo pumps on.

Tuesday, July 21, 2020, 13:16: Ion gauge on.

Tuesday, July 21, 2020, 13:40: Lockout / power / sources on.


Wednesday, July 22, 2020, 09:28: Auto-ramping TGHT / TBHT to 100 / 100 A @ 4 A per min.

Wednesday, July 22, 2020, 09:54: Auto-ramping TGHT / TBHT to 200 / 200 A @ 4 A per min.

Wednesday, July 22, 2020, 10:30: Visual note @ 200 A. No glow noted on target or the legs. Auto-ramping TGHT / TBHT to 300 / 300 A @ 4 A per min.

Wednesday, July 22, 2020, 10:57: Visual note @ 300 A. The target is glowing & reflecting the glow on the legs. The glow is even. Vacuum @ 2.95e-06T (Allow to stabilize).

Wednesday, July 22, 2020, 11:05: Vacuum @ 2.24e-06T. Auto-ramping TGHT / TBHT to 400 / 400 A @ 4 A per min.

Wednesday, July 22, 2020, 11:26: Auto-ramp aborted. TGHT heating OK. TBHT moving off?

TGHT: "Set" to 384 A = 383.6 A

TBHT: "Set" to 384 A = 318.2 A

Wednesday, July 22, 2020, 11:34: Manually tap down by 10 A. TBHT increases as TGHT decreases.

TGHT: "Set" to 374 A = 373.6 A

TBHT: "Set" to 374 A = 325.4 A

Wednesday, July 22, 2020, 11:35: Manually tap down TGHT only by 10 A. TBHT increases as TGHT decreases.

TGHT: "Set" to 364 A = 363.4 A

TBHT: "Set" to 374 A = 331.3 A

Wednesday, July 22, 2020, 11:37: Manually tap down TBHT only by 10 A. No change.

TGHT: "Set" to 364 A = 363.4 A

TBHT: "Set" to 364 A = 331.4 A

Wednesday, July 22, 2020, 11:39: Manually tap down TGHT down to 350 A. TBHT increases as TGHT decreases.

TGHT: "Set" to 350 A = 349.5 A

TBHT: "Set" to 364 A = 339.0 A

Wednesday, July 22, 2020, 11:40: Tap down to TGHT & TBHT to 340 A.

Wednesday, July 22, 2020, 11:43: Adjust TBHT Voltage limit from 3.001 to 4.001 V.

Wednesday, July 22, 2020, 11:44: Manually tap up both TGHT &TBHT to 350 A.

TGHT: "Set" to 350 A = 349.5 A

TBHT: "Set" to 350 A = 348.9 A

Wednesday, July 22, 2020, 11:45: Auto-ramping TGHT / TBHT to 400 / 400 A @ 4 A per min.

Wednesday, July 22, 2020, 12:43: Auto-ramping TGHT / TBHT to 500 / 500 A @ 4 A per min.

Wednesday, July 22, 2020, 12:59: Adjust TBHT voltage limit from 4.001 to 6.001 V

Wednesday, July 22, 2020, 13:11: Visual note @ 500 A. The target  is glowing bright. Vacuum @ 2.51e-06T

Auto-ramping TGHT / TBHT to 550 / 550 A @ 4 A per min.

Wednesday, July 22, 2020, 13:25: TGHT / TBHT @ 550 A. Vacuum @ 2.74e-06T

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 27.59 8.17
 TBHT 27.37

11.06

 COIL + EE 27.18 3.78
 TGHT  27.32 7.65

 Wednesday, July 22, 2020, 13:27: Auto-ramping TGHT / TBHT to 600 / 600 A @ 4 A per min.

Wednesday, July 22, 2020, 13:41: TGHT / TBHT @ 600 A. Vacuum @ 3.23e-06T

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 27.69 8.61
 TBHT 27.44

11.30

 COIL + EE 27.28 3.97
 TGHT  27.43 7.91

Target visual. Center hot / Legs Ok. Bright. Use welding glasses to view. 

Attachment 1: P2N_-_1_-_July-20-22-2020.docx
  803   Tuesday, July 28, 2020, 13:27 Aaron Schmidt      Problems/SolutionsWater leak on magnet PS

 Fault: 13334

Tuesday, July 28, 2020, 12:00: Leak discovered in ISAC Test Stand MB1 PS. Appears to be coming from hose barb soldered connection to heat sink of pass bank. Pass bank will need to be disassembled and heat sink soldered on a workbench.

  804   Tuesday, August 04, 2020, 15:07 Aaron SchmidtUCxLP-SIS  44139-1043515-4In progressUCx HS conditioning with PEEK assembly

 Tuesday, August 04, 2020, 15:04: Roughing.


Wednesday, August 05, 2020, 06:08: Turbo pumps on. 


Thursday, August 06, 2020, 06:58: Vacuum @ 1.52e-06T

Thursday, August 06, 2020, 07:01: Waterlines opened. Vacuum ok @ 1.52e-06T

Thursday, August 06, 2020, 07:03: Power / Sources on.

Thursday, August 06, 2020, 07:05: Auto-ramping TGHT / TBHT to 300 / 150 A @ 4A per min.

Thursday, August 06, 2020, 07:13: Adjust TBHT Voltage limit back to 3.001 V.

Thursday, August 06, 2020, 07:52: IV4 opened. HV PS on.

Thursday, August 06, 2020, 07:53: Optics up to FC0 on.

Thursday, August 06, 2020, 08:03: BIAS /  EE / EZL @ 30 / -1.5 / 13 kV.

Thursday, August 06, 2020, 08:27: Auto-ramping TGHT / TBHT to 580 / 230 A @ 2A per min.

Thursday, August 06, 2020, 11:17: BIAS /  EE / EZL @ 40 / -2.0 / 17 kV.

(monitor) Next set below

Thursday, August 06, 2020, 12:00: BIAS / EE / EZL @ 45 / 2.25 / 20.

Thursday, August 06, 2020, 12:17: BIAS / EE / EZL @ 50 / 2.5 / 22. Sparks on EE (K) cap sprak gap?

Thursday, August 06, 2020, 12:31: While tapping up the HV , (52 kV approx) , the system tripped due to a large spark around 12:25 pm. Reset req'd

Thursday, August 06, 2020, 12:33: Auto-ramping TGHT / TBHT to 580 / 230 A @ 6A per min.

Thursday, August 06, 2020, 12:43: BIAS /  EE / EZL @ 30 / -1.5 / 13 kV.

Thursday, August 06, 2020, 13:24: Halt auto ramp. Odd behaviour on TBHT CUR/VOL & TGHT VOL.

Thursday, August 06, 2020, 13:27: Warped. Visual short on TBHT. Auto-cool @ 4 A per min.

Thursday, August 06, 2020, 13:32: HV off. IV4 closed.


Tuesday, August 11, 2020, 07:02: Power/sources off.

Tuesday, August 11, 2020, 07:06: Ion gauge IG1, Turbo pumps off.

 

Attachment 1: UCx_-_HS_w-PEEK_Assy_-_43515-4.docx
  805   Wednesday, August 05, 2020, 10:01 Aaron Schmidt      Problems/SolutionsRoughing pump swap out.

Wednesday, August 05, 2020, 10:00: TP6 & TP2 off. IG6 off.

Wednesday, August 05, 2020, 12:20: RP2 swapped with a smaller roughing pump from the hot lab.

Wednesday, August 05, 2020, 12:25:  Roughing.

Wednesday, August 05, 2020, 13:53: Open BV2 to beam line chamber.

Wednesday, August 05, 2020, 14:21: Turbo pumps on.

Wednesday, August 05, 2020, 14:25: Ion gauge on. Turbo pumps at speed.

  806   Tuesday, August 11, 2020, 12:04 Aaron SchmidtUCxLP-SIS  44139-1043515-4In progressUCx HS conditioning with PEEK assembly

HS target leg openings were milled. Short from previous test by the look of it. TBHT insulator on source side is cracked.

Wiring up top adjusted for better clearance. EE (K) Cap appears ok.

Tuesday, August 11, 2020, 12:03: Roughing.

Tuesday, August 11, 2020, 12:43: Turbo pumps on.

Tuesday, August 11, 2020, 12:50: Ion gauge on.


Wednesday, August 12, 2020, 06:47: Waterlines opened. Vacuum stable @ 1.76e-06T.

Wednesday, August 12, 2020, 06:51: Power / Sources / Optics on (Half to FC0).

Wednesday, August 12, 2020, 06:53: Auto-ramping TGHT / TBHT to 350 / 150 A @ 2 A per min.

Wednesday, August 12, 2020, 06:54: IV4 opened.

Wednesday, August 12, 2020, 11:36: Auto-ramping TGHT / TBHT to 580 / 230 A @ 2 A per min.

Wednesday, August 12, 2020, 14:10: TGHT / TBHT voltages ok.

Wednesday, August 12, 2020, 14:23: BIAS / EE / EZL @ 30 / -1.5 / 13 kV.

Wednesday, August 12, 2020, 15:00: BIAS / EE / EZL @ 35 / -1.7 / 15 kV. 

Wednesday, August 12, 2020, 15:06: BIAS /  EE / EZL @ 40 / -2.0 / 17 kV. Spark* audible.

reset steering & IG6.

Wednesday, August 12, 2020, 15:08: Spark*

Wednesday, August 12, 2020, 15:17: BIAS / EE / EZL @ 45 / 2.25 / 20. spark*

Sparks* Reset IV4, TP6, steering & IG6.

Wednesday, August 12, 2020, 15:20: BIAS /  EE / EZL @ 40 / -2.0 / 17 kV.

Wednesday, August 12, 2020, 15:24: Optics Q1 not resetting.

Wednesday, August 12, 2020, 15:29: HV to 0 kv


Thursday, August 13, 2020, 07:32: TPS:Q1 has not revived on the V+ setting. Comes back on V-. Multiple attempts to engage the PS, turning it off & on. Leaving it in "ON" status but 0V.

Thursday, August 13, 2020, 07:45: BIAS / EE / EZL @ 30 / -1.5 / 13 kV.

Thursday, August 13, 2020, 08:27: Sparks* 3 audible, almost back to back. only TPS:Q1 affected. V- jumped from 0V to 1500V on it's own. Reset to 0V.

Thursday, August 13, 2020, 08:54: BIAS / EE / EZL @ 35 / -1.7 / 16 kV. Increased EZL V to stabilize it on the strip tool.

Thursday, August 13, 2020, 10:56: Reset IG6. Spark affected.

Thursday, August 13, 2020, 11:05: Audible spark* in behind TS?

Thursday, August 13, 2020, 11:06: TPS:Q1 affected. V- jumped from 0V to 1500V on it's own. Reset to 0V.

Thursday, August 13, 2020, 11:12: BIAS /  EE / EZL @ 40 / -2.0 / 20 kV.

Thursday, August 13, 2020, 11:21: Spark* Charged up both TSG:CBC to 2500 V. Reset to 500 V.

Thursday, August 13, 2020, 13:50: BIAS / EE / EZL @ 45 / -2.2 / 21 kV.

Thursday, August 13, 2020, 14:11: Spark* Minor.

Thursday, August 13, 2020, 14:15: BIAS / EE / EZL @ 50 / -2.5 / 22.5 kV.

Thursday, August 13, 2020, 14:18: Spark. Knocked out IV4, TP6, & optics. Reset. Oh and would you look at that TPS:Q1 works now. Set to 790 V.

Thursday, August 13, 2020, 14:21: Spark*

Thursday, August 13, 2020, 14:24: Spark* but not audible. They're decreasing in size.

Thursday, August 13, 2020, 14:31: Audible spark*. Reset TSG:CBC & TPS:Q1

Thursday, August 13, 2020, 15:01: Observed the spark in the spark gap EE (K).

Thursday, August 13, 2020, 15:19: BIAS / EE / EZL to 0 kV. HV off. Optics off.


Monday, August 17, 2020, 10:57: Begin slow auto-cooling @ -0.75 A per min. 

 

  807   Tuesday, August 18, 2020, 10:00 Aaron Schmidt       IDP15 Scroll pump installed - RP1 replaced

PN: X3815-64000

SN: MY2005SA02

Description: IDP15 Scroll pump, Std.

Removed old Tri-Scroll, Check voltage setting. set to 115V.

Tuesday, August 18, 2020, 09:57: Installed & check. Roughing line to PV1

Tuesday, August 18, 2020, 10:04: Connection ok. Await chamber close after.

Tuesday, August 18, 2020, 13:30: Disengage shipping locks*

  808   Tuesday, August 18, 2020, 12:07 Aaron SchmidtTest FEBIADHP-FEBIAD  38295-842752-5In progressRP check & Mass magnet check.

Tuesday, August 18, 2020, 12:05: RP1 on

Tuesday, August 18, 2020, 12:10: RP1 off

Install Gas Ballast vapour port w/ filter.

Tuesday, August 18, 2020, 13:19: RP1 on

Disengage shipping locks*

Tuesday, August 18, 2020, 13:55: Turbo pumps on.

Tuesday, August 18, 2020, 14:02: TP1 A trip. TSG:CG1A pressure issue. Remove filter port on Gas ballast. Add blank.

TSG:CG1A pressure improving.

Tuesday, August 18, 2020, 14:37: TP1 A trip. TSG:CG1A pressure issue.

Tuesday, August 18, 2020, 14:48: Bypass BV1A. Switch on TP1 A.

Tuesday, August 18, 2020, 14:55: No trips* Bypass to remain until CG1A below 0.050T.

Tuesday, August 18, 2020, 21:58: Bypass removed. CG1A @ 0.041T.

 

 

  809   Wednesday, August 19, 2020, 08:52 Aaron Schmidt       Leak check / Troubleshoot

Wednesday, August 19, 2020, 08:52: Purging all lines, except FS#5, It was already purged / closed.

Wednesday, August 19, 2020, 11:24: Vacuum @ 1.76e-06T.

Wednesday, August 19, 2020, 11:29: FS#2 opened. Observable vacuum spike noted. vacuum @ 2.2e-06T. Purge & Close.

Wednesday, August 19, 2020, 11:34: Vacuum @  1.76e-06T.

Wednesday, August 19, 2020, 11:36: FS#3 opened. Vacuum  @ 1.74e-06T.

Wednesday, August 19, 2020, 11:44: Vacuum @  1.67e-06T.

Wednesday, August 19, 2020, 11:47: FS#4 opened. Vacuum @ 1.65e-06T

Wednesday, August 19, 2020, 11:51: No spike observed

Wednesday, August 19, 2020, 11:52: Turbo Pumps off. To vent for Leak check w/ LD & He.


Thursday, August 20, 2020, 11:26: Blanked off & connected feed through (C) & (D) individually. Both to 120 PSI individually w/ He. No leak detected. 

Thursday, August 20, 2020, 11:35: Roughing.

Thursday, August 20, 2020, 13:00: TP1B started.

Thursday, August 20, 2020, 13:09: Before opening back valve w/ LD:

LD: 0.0e-09 atm-cc/sec

Thursday, August 20, 2020, 13:10: Opened valve.

LD: 2.2e-07 atm-cc/sec & Dropping. Likely left over from the lines initial tests. Vacuum @ 3.2e-04T & dropping.

Thursday, August 20, 2020, 13:17: 120 PSI of He on line (D) TGHT left side.

 LD: 1.3e-07 atm-cc/sec & Dropping. Vacuum @ 2.09e-04T & dropping.

Thursday, August 20, 2020, 13:27: LD: 1.0e-07 atm-cc/sec & Dropping. Vacuum @ 1.27e-04T & dropping. Disconnect He up top.

Thursday, August 20, 2020, 13:40: LD: 1.2e-07 atm-cc/sec. Vacuum @ 9.95e-05T & dropping. Connected He up top to line (C) TGHT right side.

Thursday, August 20, 2020, 13:43: 120 PSI on line. Spike occurring on TSG CG1A & TSG:CG1 B.

Thursday, August 20, 2020, 13:53: LD: 2.0e-07 atm-cc/sec. Vacuum @ 7.57e-05T & dropping. Gradual increase on leak rate for line (C)


Tuesday, August 25, 2020, 07:07: Beam line side of the TS tripped? Open BV6 & BV2.

Tuesday, August 25, 2020, 07:15: Beam line side TP6 & TP2 on.

Tuesday, August 25, 2020, 07:16: Venting Chamber side

Tuesday, August 25, 2020, 15:39: Aluminum water loop block installed. Roughing.

Tuesday, August 25, 2020, 19:11: Turbo pumps TP1A & TP1B on.

Tuesday, August 25, 2020, 19:13: TP1A off to avoid a trip.

Tuesday, August 25, 2020, 19:50: TP1A on. BV1A Bypass on 

Tuesday, August 25, 2020, 19:58: Ion gauge on. 


Wednesday, August 26, 2020, 06:15: BV1A Bypass off.


Multiple checks done on right TGHT (C) in the cold lab. Inconclusive leak detection

Reconnect He & LD to TS. TGHT (C) with Loop block in place.

Thursday, August 27, 2020, 08:09: Vacuum @ 1.49e-06T

Thursday, August 27, 2020, 08:11: Before opening back valve w/ LD:

LD: 0.0e-09 atm-cc/sec

Thursday, August 27, 2020, 08:13: Opened valve behind TP1B.

Thursday, August 27, 2020, 08:16:

LD: 0.0e-09 atm-cc/sec. Vacuum @ 1.49e-06T.

Thursday, August 27, 2020, 08:18: 120 PSI of He on line (C) TGHT Right side w/ loop block.

Thursday, August 27, 2020, 08:21: LD:  0.0e-09 atm-cc/sec. Vacuum @ 1.49e-06T.

Thursday, August 27, 2020, 08:31: Increase /  bump noted on LD

Thursday, August 27, 2020, 08:34: LD: 1.4e-08 atm-cc/sec. Slowly increasing. Vacuum @ 1.49e-06T.

Thursday, August 27, 2020, 08:39: LD: 4.0e-08 atm-cc/sec. Slowly increasing. Vacuum @ 1.49e-06T.

Thursday, August 27, 2020, 08:42: Closed Valve behind TP1B. Purge He.

Thursday, August 27, 2020, 10:02: Ion gauge off. Turbo pumps off.

Thursday, August 27, 2020, 11:04: Venting:

Removed loop block. Polished/Cleaned seat surface to remove 2 scratches. Applied no o-rings w/ vacuum grease. Pressurized with 120 PSI on the line w/ sniffer. No leak detected.

Thursday, August 27, 2020, 13:44: Roughing.

Thursday, August 27, 2020, 13:46: BV1A opened.

Thursday, August 27, 2020, 17:39: TP1B on.

Thursday, August 27, 2020, 17:52: TP1A on 


 

Tuesday, September 01, 2020, 07:44: Vacuum @ 8.23e-07T

Before opening back valve w/ LD: 0.0e-09 atm-cc/sec

Tuesday, September 01, 2020, 07:46: Opened valve behind TP1B.

Tuesday, September 01, 2020, 07:57: LD: 0.0e-09 atm-cc/sec. Vacuum @ 8.23e-07T.

Tuesday, September 01, 2020, 07:59: 120 PSI of He on line (C) TGHT Right side w/ loop block.

Tuesday, September 01, 2020, 08:20: LD:  0.0e-09 atm-cc/sec. Vacuum @ 8.16e-07T.

Tuesday, September 01, 2020, 08:21: Random Spike? Vacuum remained the same, however the LD jumped from 0.0e-09 atm-cc/sec to the mid-e-08 atm-cc/sec range. Literally for a couple seconds, then back to 0.0e-09 atm-cc/sec.

Odd, couple more random spikes.

Tuesday, September 01, 2020, 08:24: Closed valve behind TP1B to see if the spikes continue.

Tuesday, September 01, 2020, 08:34: Opened the TP1B valve. Immediate spike from 0.0e-09 atm-cc/sec to 2.2e-08 & 7.9e-08 atm-cc/sec noted.

Tuesday, September 01, 2020, 08:36: Close the valve behind TP1B. LD off.

Tuesday, September 01, 2020, 14:00:

New tubing installed.

Blue on FS#4 loop (A)(B)

Yellow on FS#2 Loop (C)(D)

Vacuum @ 8.30e-07T

Tuesday, September 01, 2020, 14:04: Opened FS#4 Vacuum stable @ 8.30e-07T.

Tuesday, September 01, 2020, 14:06: Opened FS#2 Vacuum stable @ 8.30e-07T.

Tuesday, September 01, 2020, 14:36: Closed FS#2 but not purged.. Vacuum stable @ 8.23e-07T.


Wednesday, September 02, 2020, 07:26: Ion gauge & Turbo pumps off. 

Wednesday, September 02, 2020, 08:50: Venting.

Install right TGHT (C)(D) line. Install FEBIAD. Clean out odd buildup / powder beneath optics tray.

Wednesday, September 02, 2020, 10:48: Roughing.

Wednesday, September 02, 2020, 11:19: TP1B on.


Thursday, September 03, 2020, 11:00: Vacuum @ 1.05e-06T. Waterlines are to be opened.

Thursday, September 03, 2020, 11:03: Opened FS#2. Vacuum Stable @ 1.03e-06T.

Thursday, September 03, 2020, 11:05: Opened FS#3. Vacuum Stable @ 1.03e-06T.

Thursday, September 03, 2020, 11:06: Opened FS#4. Vacuum Stable @ 1.03e-06T.

Thursday, September 03, 2020, 11:08: Opened FS#5. Vacuum Stable @ 1.03e-06T.

Thursday, September 03, 2020, 11:23: Vacuum remains stable @ 1.03e-06T.. PS on. Auto-ramp TGHT / TBHT to 350 / 150 A @ 2 A per min.

 

 

Attachment 1: Aug_19_-_2020_Leak_Check..docx
  810   Tuesday, August 25, 2020, 07:23 Aaron Schmidt      Problems/SolutionsBeam line side vacuum trip

Tuesday, August 25, 2020, 07:07: Beam line side of the TS appears to have tripped? Open BV6 & BV2.

Tuesday, August 25, 2020, 07:15: Beam line side TP6 & TP2 on.

Tuesday, August 25, 2020, 07:16: Venting Chamber side

Trip appears to have occurred at 6am on Saturday.

Contacted MCR. Power bump occurred.

 

  811   Tuesday, September 01, 2020, 14:01 Aaron Schmidt      DoneNew tubing installed on loops

Tuesday, September 01, 2020, 14:00:

New tubing installed.

Blue on FS#4 loop (A)(B)

Yellow on FS#2 Loop (C)(D)

  812   Thursday, September 03, 2020, 11:28 Aaron Schmidt-HP-FEBIAD  38295-842752-5In progressLeak check 2.0

Out Gas & MB1 check (Or leak check 2.0)

Ref: https://elog.triumf.ca/TIS/Test-Stand/809 - Leak Checks

Ref: https://elog.triumf.ca/TIS/Test-Stand/803 - Fault

WP I2020-08-19-1 For MB1 work

Thursday, September 03, 2020, 11:23: Vacuum remains stable @ 1.03e-06T.. PS on. Auto-ramp TGHT / TBHT to 350 / 150 A @ 2 A per min.

Thursday, September 03, 2020, 13:06: TS Tripped. Vacuum Spikes again. Appears the water leak is still ongoing.

Thursday, September 03, 2020, 13:49 Waterlines are all close. Vacuum becoming more stable.


Tuesday, September 08, 2020, 07:40: Ion Gauge & turbo pumps off.


Wednesday, September 09, 2020, 06:13: Venting.  


FS#2 - R TGHT (C) feed through and section had been removed and re-souldered both on the water block and the feed through.

Tuesday, September 15, 2020, 09:47:  Roughing.

Tuesday, September 15, 2020, 10:47: TP1B on.

Tuesday, September 15, 2020, 14:35 :TP1A on.

Tuesday, September 15, 2020, 14:42 : IG1 on.


Wednesday, September 16, 2020, 07:44: Vacuum @ 6.00e-06T.

Wednesday, September 16, 2020, 07:47: FS#2 waterline opened. Vacuum stable @ 6.00e-06T.

Wednesday, September 16, 2020, 08:02: Vacuum @ 5.97e-06T. Vacuum stable.

Wednesday, September 16, 2020, 08:03: FS#3 open. Vacuum stable.

Wednesday, September 16, 2020, 08:09: FS#4 open. Vacuum stable.

Wednesday, September 16, 2020, 08:24: FS#5 open. Vacuum stable @ 5.91e-06T.

No vacuum spikes noted.

Wednesday, September 16, 2020, 08:42: PS on. Note: Once Vacuum reaches 3.5e-06T, begin auto-ramping.

Wednesday, September 16, 2020, 09:25: It appears the leak is still here. But very subtle. Vacuum @ 6.18e-06T. Many curse words uttered. PS off. Locked out. Purge waterlines.


Thursday, September 17, 2020, 08:21: Vacuum @ 3.32e-06T.

Thursday, September 17, 2020, 08:23: Opened FS#5.

Thursday, September 17, 2020, 08:55: Opened FS#4. Vacuum @ 3.12e-06T.

Thursday, September 17, 2020, 09:51: Opened FS#3. Vacuum @ 3.12e-06T

Thursday, September 17, 2020, 10:21: Opened FS#2 Vacuum @ 3.12e-06T.

Thursday, September 17, 2020, 10:52: Gradual climb on IG1. Vacuum @ 4.44e-06T.

Thursday, September 17, 2020, 10:53: IG1 & turbo pumps off. Purge water from FS#2.

Thursday, September 17, 2020, 11:37: Venting.

Checked: Upper line & Lower line independently. No obvious leak detected. Checked O-rings. Replaced w/ C-Seals.

Thursday, September 17, 2020, 13:31: Roughing.

Thursday, September 17, 2020, 14:06: TP1B on. 

Thursday, September 17, 2020, 19:11: TP1A on. 


Friday, September 18, 2020, 12:07: FS#2 opened. Vacuum @ 2.48e-06T 

Friday, September 18, 2020, 12:12: FS#2 Closed. Vacuum spiked to near 6.0e-05T. 

Friday, September 18, 2020, 12:15: FS#2 fully purged. 


Tuesday, September 22, 2020, 06:51: Ion gauge & Turbo pumps off. 

Tuesday, September 22, 2020, 08:10: Venting.

O-rings swapped for fresh new ones w/ vacuum grease on (C) & (D) water blocks.

Tuesday, September 22, 2020, 09:27: Roughing.

Tuesday, September 22, 2020, 10:10: TP1B on. 

Tuesday, September 22, 2020, 12:20: TP1A on. 

Tuesday, September 22, 2020, 15:02: Vacuum @ 2.97e-06T.

Tuesday, September 22, 2020, 15:05: Opened FS#2. No immediate response.

Tuesday, September 22, 2020, 15:13: Gradual vacuum spike to 2.6e-06T. Closed FS#2


Wednesday, September 23, 2020, 06:36: Ion gauge & turbo pumps off. 

Wednesday, September 23, 2020, 11:38: TP1B on only. IG1 on.

Wednesday, September 23, 2020, 15:37: LD:  0.0e-09 atm-cc/sec. Vacuum @3.9e-06T.

Wednesday, September 23, 2020, 15:38: Open valve to TP1B.

Wednesday, September 23, 2020, 15:41:

LD: 0.0e-09 atm-cc/sec. Vacuum @3.67e-06T.

Wednesday, September 23, 2020, 15:51: LD: 0.0e-09 atm-cc/sec. Vacuum @3.67e-06T. No response on LD.

Wednesday, September 23, 2020, 15:57: 70 PSI of He on line (C) TGHT Right side. LD: 0.0e-09 atm-cc/sec. Vacuum @3.73e-06T. Flush line

Wednesday, September 23, 2020, 15:59: LD: 1.7e-09 atm-cc/sec. & Rising.

Wednesday, September 23, 2020, 16:00: LD: 4.1e-09 atm-cc/sec & rising. Line (C) confirmed again.

Wednesday, September 23, 2020, 16:04: LD & He disconnected. IG1 & TP1B off. Remove (C) Right TGHT line in the morning. Will aim to replace the source tray side. Feed through side has already been done.


Thursday, September 24, 2020, 07:16: Venting. 

Remove FEBIAD & Source tray side R-TGHT line (C) from FS#2. Blank off with blind double block.

Thursday, September 24, 2020, 08:41: Roughing

Thursday, September 24, 2020, 09:12: TP1B on.

Thursday, September 24, 2020, 09:18: Ion gauge on.

Thursday, September 24, 2020, 10:17: TP1A on. 

Thursday, September 24, 2020, 14:20: Connect LD & Set-up He. Vacuum @ 2.92e-06T. LD: 0.0e-09 atm-cc/sec.

Thursday, September 24, 2020, 14:22: Open valve to TP1B.

Thursday, September 24, 2020, 14:24: Vacuum @ 2.95e-06T. LD: 2.2e-08 atm-cc/sec. 70 PSI of He on line (C) TGHT Return side.

Thursday, September 24, 2020, 14:30: Vacuum @ 2.74e-06T. LD: 1.5e-08 atm-cc/sec.

Minimal change.


 Tuesday, September 29, 2020, 04:50: IG1 off. Turbo pumps off.

  813   Tuesday, September 29, 2020, 11:56 Aaron Schmidt LP-SIS    Problems/SolutionsLeak check 3.0

Installed Indium gasket on FS#2 - (C) water block / R- TGHT.

Tuesday, September 29, 2020, 11:23: Pressurize to 120 PSI at atmosphere.

LD: 0.0E-07 atm-CC/sec

Tuesday, September 29, 2020, 11:30: LD: 0.0E-07 atm-CC/sec checked & held on gasket / water block (C) for min minutes. No LD response.

Tuesday, September 29, 2020, 11:56: Roughing.

Tuesday, September 29, 2020, 12:28: TP1B on.

Tuesday, September 29, 2020, 13:10: TP1A on. IG1 on.

Tuesday, September 29, 2020, 16:10: Vacuum @ 8.66e-06T.

Tuesday, September 29, 2020, 16:13: FS#2 opened. Vacuum @ 8.48e-06T.

Tuesday, September 29, 2020, 16:23: Opened FS#5. Vacuum ok

Tuesday, September 29, 2020, 16:25: Opened FS#4. Vacuum ok

Tuesday, September 29, 2020, 16:27: Opened FS#3 Vacuum ok @ 8.13e-06T.

 

  814   Wednesday, September 30, 2020, 06:23 Aaron SchmidtC#2LP-SISITWTM244139-943515-2In progressConditioning C#2

Wednesday, September 30, 2020, 06:14: Power / sources on.

Wednesday, September 30, 2020, 06:17: Auto-ramping TGHT / TBHT to 300 / 150 A @ 3 A per min.

Wednesday, September 30, 2020, 06:22: Optics set (minus MB1).

Wednesday, September 30, 2020, 07:11: Pair of gradual vacuum spikes noticed. Up to 3.5e-06T & 2.6e-06T, then back down to 2.3e-06T.

Wednesday, September 30, 2020, 07:59: Auto-ramping TGHT / TBHT to 450 / 200 A @ 3 A per min.

Wednesday, September 30, 2020, 08:04: Abort auto-ramping. BIAS @ 10 kV. EZL Appears to have a short. EE up to -1.5 kV ok.

Wednesday, September 30, 2020, 08:11: BIAS back to 0 kV. Auto cooling @ 4A per min.

Wednesday, September 30, 2020, 09:21: Tap down TGHT to 0 from 40 A.

Wednesday, September 30, 2020, 09:22: Power/sources off.

Wednesday, September 30, 2020, 09:23: IG1 & Turbo pumps off.

Wednesday, September 30, 2020, 10:48: Venting.

Wednesday, September 30, 2020, 11:31: Wire found touching on EZL to chamber. Bypassed interlocks. EZL on. 200 V ok 500 V ok. Back to 0V.

Wednesday, September 30, 2020, 11:33: Bypasses removed.

Wednesday, September 30, 2020, 11:37: Roughing.

Wednesday, September 30, 2020, 12:22: Turbo pumps on. 

Wednesday, September 30, 2020, 16:41: TGHT / TBHT to 10 / 10 A manually. BIAS / EE / EZL @ 1 / 0.1 / 1 kV. No shorts. Vacuum @ 2.60e-06T.  

Wednesday, September 30, 2020, 16:47: HV & Heaters tapped back to 0 A & 0 kV. 


Thursday, October 01, 2020, 05:27: Auto-ramping TGHT / TBHT to 150 / 75 A @ 3 A per min.

Thursday, October 01, 2020, 07:04: Auto-ramping TGHT / TBHT to 300 / 150 A @ 3 A per min. 

Thursday, October 01, 2020, 07:29: Optics on. (MB1 Still interlocked but connected now)

Thursday, October 01, 2020, 07:38: BIAS / EE / EZL @ 30 / -1.5 / 13 kV

Thursday, October 01, 2020, 07:39: IV4 open.

Thursday, October 01, 2020, 07:55: Auto-ramping TGHT / TBHT to 580 / 230 A @ 2 A per min.

Thursday, October 01, 2020, 08:34: Voltage drops on BIAS. Auto ramping halted.

Thursday, October 01, 2020, 08:37: BIAS / EE / EZL @ 15 / -1.0 / 8.5 kV.

Thursday, October 01, 2020, 10:04: Auto-ramping TGHT / TBHT to 450 / 230 A @ 1 A per min.

Thursday, October 01, 2020, 11:13: Auto-ramping TGHT / TBHT to 580 / 230 A @ 1 A per min.

Thursday, October 01, 2020, 14:31: BIAS / EE / EZL @ 30 / -1.5 / 13 kV. BIAS instability ongoing. although less than before. Initial RPM0A & RPM0B wire scans ok. MB1 Still interlocked.

Thursday, October 01, 2020, 14:42: BIAS current limit increased to 0.150 mA

Thursday, October 01, 2020, 16:24: BIAS / EE / EZL @ 20 / -1.5 / 6.5 kV.


Friday, October 02, 2020, 09:55: BIAS / EE / EZL @ 25 / -1.5 / 10 kV.

Friday, October 02, 2020, 10:43: Spark* Tripped Optics, IV4 & TP1A. Optics reset. Trouble on IV4 & TP1A

Friday, October 02, 2020, 10:58: IV4 reset. TP1A not back yet. 

Friday, October 02, 2020, 11:22: TP1A reset and on. 

Friday, October 02, 2020, 12:19: BIAS / EE / EZL @ 30 / -1.5 / 13 kV.

Friday, October 02, 2020, 13:58: HV to 0 kV 

Friday, October 02, 2020, 14:00: Auto-Cooling @ 1 A per min.


Tuesday, October 13, 2020, 08:07: Power / sources off. HS Waterlines purged.

Tuesday, October 13, 2020, 08:09: IG1 off. Turbo pumps off.

Tuesday, October 13, 2020, 10:31: Venting. 

Attachment 1: C#2_-_Short_-_EZL.docx
Attachment 2: C#2_Conditioning.docx
Attachment 3: ITW-TM2-C#2-LP-SIS_Test_Stand.docx
  815   Tuesday, October 13, 2020, 12:34 Aaron Schmidt HP-FEBIAD  38295-842752-5In progressMB1 Check.

He & Ar calibrated leak bottles in.

Tuesday, October 13, 2020, 12:33: Roughing.

Tuesday, October 13, 2020, 13:17: TP1B on.

Tuesday, October 13, 2020, 14:19: TP1A on. 

Tuesday, October 13, 2020, 15:44: Waterlines opened. Vacuum @ 9.58e-06T & dropping. Power on.

Tuesday, October 13, 2020, 15:49: Valve to Mini-pump was open & the pump happened to already be switched on.

Tuesday, October 13, 2020, 15:50: Open SV3 & SV4.

Tuesday, October 13, 2020, 15:55: Close mini-pump & switch off. SV3 & SV4. Briefly open/close SV5. Continue until vacuum stabilizes.

Tuesday, October 13, 2020, 15:59: SV5 open. Alt SV3 & SV4 w/ SV5 until stable.

Tuesday, October 13, 2020, 16:04: Gas lines SV3, SV4, SV5 open. Vacuum @ 9.96e-06T & dropping.

Tuesday, October 13, 2020, 22:30: PS on. Vacuum @ 2.13e-06T. Auto-ramping TGHT / TBHT to 300 / 150 A @ 1 A per min.  

Tuesday, October 13, 2020, 22:33: Anode* Short? Halt auto-ramping.

Tuesday, October 13, 2020, 22:35: Auto-ramping TGHT / TBHT to 100 / 50 A @ 1 A per min. Coil @ 10 A.


Wednesday, October 14, 2020, 05:19: Auto-ramping TGHT / TBHT to 300 / 150 A @ 1 A per min.  

Wednesday, October 14, 2020, 07:14: BIAS / EE / EZL to 20 / -1.5 / 10 kV. IV4 opened.

Wednesday, October 14, 2020, 10:30: Auto-ramping TGHT to 350 A @ 2 A per min.

Wednesday, October 14, 2020, 11:11: BIAS / EE / EZL to 30 / -1.5 / 13 kV. 

Wednesday, October 14, 2020, 11:12: Auto-ramping TGHT / TBHT to 580 / 230 A @ 2 A per min. 


Thursday, October 15, 2020, 14:13: MB1 connected.

Epics = Readback

10 A = 11.6 A

0.394 V = 0.39 V

Calibration required, but it's running.

Thursday, October 15, 2020, 14:33: Auto-Cooling. Tap down HV. 

Thursday, October 15, 2020, 14:36: Gas lines closed. 


Friday, October 16, 2020, 07:55: Power / sources off. IG1 off. Turbo pumps off.

Friday, October 16, 2020, 07:56: HS Waterlines purged.

Friday, October 16, 2020, 10:07: Venting.

Attachment 1: MB1_Check_Oct_-_2020.docx
  816   Friday, October 16, 2020, 11:33 Aaron SchmidtTa#61LP-SISITETM444508-143515-1In progressConditioning Ta#61

Friday, October 16, 2020, 11:11: Roughing.

Friday, October 16, 2020, 11:39: TP1B on.

Friday, October 16, 2020, 12:29: TP1A on. 


Monday, October 19, 2020, 07:59: Waterlines opened. Vacuum ok @ 6.20e-07T

Monday, October 19, 2020, 08:01: Power / Sources on.

Monday, October 19, 2020, 08:02: Auto-ramping TGHT / TBHT to 350 / 150 A @ 2 A per min.

Monday, October 19, 2020, 08:03: IV4 opened.

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 23.43 5.86
 TBHT 23.34

8.52

 COIL + EE 23.36 2.65
 TGHT 23.27 6.45

Monday, October 19, 2020, 08:09: Optics on / set.

Monday, October 19, 2020, 08:16: BIAS / EE / EZL @ 30 / -1.5 / 13 kV.

Monday, October 19, 2020, 12:47: Auto-ramping TGHT / TBHT to 580 / 230 A @ 2 A per min. 

Monday, October 19, 2020, 15:50: Initial wire scans were good. MB1 requires a polarity reversal

Monday, October 19, 2020, 16:00: Auto-cooling TGHT / TBHT to 300 / 10 A @ 1 A per min. Stop manually.

Monday, October 19, 2020, 18:11: TBHT @ 100 A halt. Auto-cooling TGHT to 300 @ 1 A per min. Stop manually.

Monday, October 19, 2020, 19:16: TGHT @ 300 A halt.


Tuesday, October 20, 2020, 06:15: Auto-ramping TGHT / TBHT to 580 / 230 A @ 2 A per min. 

Tuesday, October 20, 2020, 09:30: HV off. IV4 closed. Switching MB1 polarity.

Tuesday, October 20, 2020, 13:30: BIAS / EE / EZL @ 30 / -1.5 / 13 kV. MB1 on

Tuesday, October 20, 2020, 14:10: Mass scans working

Tuesday, October 20, 2020, 14:17:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 24.64 5.87
 TBHT 24.29

8.76

 COIL + EE 24.07 2.71
 TGHT 24.25 6.54

 Tuesday, October 20, 2020, 15:15: IV4 opened. 


Thursday, October 22, 2020, 11:35: HV to 0 kV.

Thursday, October 22, 2020, 11:36: Auto-cooling @ 1 A per min. 


Monday, October 26, 2020, 11:40: IV4 closed / reset

Monday, October 26, 2020, 11:41: PS off.

Monday, October 26, 2020, 11:42: IG1 / Turbo pumps off. Purging waterlines.

Monday, October 26, 2020, 13:00: Venting.

Attachment 1: Ta#61.docx
Attachment 2: ITE-TM4-Ta#61-LP-SIS_Test_Stand.docx
Attachment 3: ER-580-230-30kV-M133.txt
value (Voltage offset      40.0000)
     75.0000
      1.0000
     95.0000
  29978.0220
21
21
./emit.dat
 -0.1190 -0.0854 -0.0906 -0.0717 -0.0562 0.2417 -0.0793 -0.0757 -0.0751 -0.0760 -0.0763 -0.0751 -0.0732 -0.0751 -0.0757 -0.0742 -0.0763 -0.0766 -0.0760 -0.0748 -0.0754
 -0.0854 -0.0784 -0.0854 -0.0720 -0.0671 -0.0546 0.1855 0.1309 -0.0748 -0.0711 -0.0702 -0.0714 -0.0708 -0.0696 -0.0705 -0.0726 -0.0684 -0.0726 -0.0745 -0.0696 -0.0702
 -0.0839 -0.0656 -0.0583 -0.0677 -0.0690 -0.0665 -0.0610 -0.0452 0.4224 -0.0671 -0.0690 -0.0693 -0.0714 -0.0681 -0.0674 -0.0717 -0.0693 -0.0662 -0.0665 -0.0674 -0.0717
 -0.0824 -0.0705 -0.0677 -0.0693 -0.0702 -0.0671 -0.0693 -0.0699 -0.0598 0.0613 0.5127 -0.0662 -0.0723 -0.0717 -0.0693 -0.0705 -0.0696 -0.0696 -0.0711 -0.0693 -0.0726
 -0.0818 -0.0705 -0.0696 -0.0677 -0.0690 -0.0693 -0.0702 -0.0696 -0.0702 -0.0677 -0.0558 0.1892 0.0259 -0.0720 -0.0708 -0.0723 -0.0696 -0.0705 -0.0732 -0.0696 -0.0723
 -0.0824 -0.0659 -0.0693 -0.0684 -0.0693 -0.0702 -0.0690 -0.0696 -0.0665 -0.0708 -0.0677 -0.0662 -0.0418 0.5542 -0.0183 -0.0708 -0.0723 -0.0732 -0.0687 -0.0702 -0.0714
 -0.0836 -0.0665 -0.0684 -0.0693 -0.0677 -0.0684 -0.0684 -0.0684 -0.0653 -0.0705 -0.0818 -0.0677 -0.0684 -0.0583 -0.0208 0.2951 -0.0677 -0.0693 -0.0699 -0.0684 -0.0702
 -0.0815 -0.0684 -0.0653 -0.0677 -0.0677 -0.0687 -0.0684 -0.0671 -0.0681 -0.0699 -0.0665 -0.0687 -0.0690 -0.0671 -0.0671 -0.0537 0.3214 0.1694 -0.0659 -0.0681 -0.0717
 -0.0790 -0.0699 -0.0684 -0.0690 -0.0702 -0.0674 -0.0693 -0.0668 -0.0668 -0.0690 -0.0793 -0.0684 -0.0696 -0.0711 -0.0690 -0.0677 -0.0665 -0.0540 0.5020 -0.0330 -0.0714
 -0.0803 -0.0687 -0.0696 -0.0674 -0.0702 -0.0684 -0.0690 -0.0677 -0.0690 -0.0699 -0.0787 -0.0674 -0.0677 -0.0681 -0.0677 -0.0708 -0.0693 -0.0656 -0.0574 0.0818 0.2869
 -0.0824 -0.0665 -0.0705 -0.0681 -0.0674 -0.0668 -0.0668 -0.0702 -0.0674 -0.0693 -0.0742 -0.0659 -0.0677 -0.0681 -0.0674 -0.0693 -0.0684 -0.0681 -0.0677 -0.0656 -0.0595
 -0.0827 -0.0674 -0.0671 -0.0665 -0.0641 -0.0681 -0.0674 -0.0684 -0.0647 -0.0714 -0.0778 -0.0681 -0.0677 -0.0671 -0.0684 -0.0671 -0.0684 -0.0687 -0.0690 -0.0674 -0.0681
 -0.0824 -0.0684 -0.0653 -0.0684 -0.0668 -0.0684 -0.0693 -0.0659 -0.0668 -0.0702 -0.0668 -0.0671 -0.0693 -0.0690 -0.0684 -0.0665 -0.0665 -0.0674 -0.0684 -0.0674 -0.0726
 -0.0806 -0.0687 -0.0674 -0.0684 -0.0708 -0.0671 -0.0690 -0.0677 -0.0674 -0.0677 -0.0824 -0.0684 -0.0702 -0.0665 -0.0690 -0.0693 -0.0681 -0.0677 -0.0708 -0.0671 -0.0711
 -0.0818 -0.0668 -0.0696 -0.0681 -0.0681 -0.0668 -0.0665 -0.0684 -0.0668 -0.0693 -0.0644 -0.0687 -0.0690 -0.0684 -0.0684 -0.0699 -0.0684 -0.0684 -0.0705 -0.0677 -0.0708
 -0.0821 -0.0656 -0.0677 -0.0665 -0.0656 -0.0671 -0.0662 -0.0671 -0.0656 -0.0687 -0.0821 -0.0659 -0.0668 -0.0668 -0.0677 -0.0681 -0.0677 -0.0690 -0.0674 -0.0681 -0.0708
 -0.0839 -0.0684 -0.0656 -0.0674 -0.0653 -0.0671 -0.0674 -0.0659 -0.0659 -0.0687 -0.0656 -0.0693 -0.0659 -0.0690 -0.0665 -0.0665 -0.0677 -0.0671 -0.0662 -0.0677 -0.0674
 -0.0821 -0.0684 -0.0671 -0.0702 -0.0671 -0.0671 -0.0681 -0.0671 -0.0671 -0.0693 -0.0748 -0.0665 -0.0684 -0.0668 -0.0677 -0.0656 -0.0677 -0.0681 -0.0653 -0.0681 -0.0711
 -0.0815 -0.0668 -0.0671 -0.0665 -0.0687 -0.0681 -0.0674 -0.0656 -0.0717 -0.0674 -0.0693 -0.0677 -0.0684 -0.0665 -0.0668 -0.0705 -0.0690 -0.0671 -0.0690 -0.0665 -0.0720
 -0.0815 -0.0665 -0.0674 -0.0659 -0.0671 -0.0668 -0.0662 -0.0653 -0.0681 -0.0668 -0.0644 -0.0647 -0.0677 -0.0681 -0.0662 -0.0699 -0.0677 -0.0671 -0.0677 -0.0665 -0.0708
 -0.0818 -0.0659 -0.0677 -0.0665 -0.0677 -0.0659 -0.0650 -0.0677 -0.0674 -0.0690 -0.0815 -0.0656 -0.0647 -0.0659 -0.0659 -0.0665 -0.0662 -0.0681 -0.0677 -0.0677 -0.0696
Attachment 4: ER-580-230-30kV-M28.txt
value (Voltage offset      40.0000)
     75.0000
      1.0000
     95.0000
  29992.6740
21
21
./emit.dat
 -0.4572 -0.0729 -0.0775 -0.0739 0.0317 0.4523 -0.0815 -0.0772 -0.0763 -0.0757 -0.0836 -0.0766 -0.0754 -0.0775 -0.0757 -0.0815 -0.0772 -0.0742 -0.0732 -0.0766 -0.0879
 -0.0876 -0.0684 -0.0677 -0.0778 -0.0690 -0.0323 0.6406 0.1349 -0.0745 -0.0726 -0.0711 -0.0735 -0.0693 -0.0690 -0.0717 -0.0784 -0.0720 -0.0714 -0.0693 -0.0708 -0.0854
 -0.0854 -0.0684 -0.0656 -0.0586 -0.0684 -0.0623 -0.0510 -0.0015 0.7645 -0.0690 -0.0757 -0.0739 -0.0720 -0.0690 -0.0702 -0.0775 -0.0717 -0.0717 -0.0690 -0.0677 -0.0858
 -0.0842 -0.0693 -0.0726 -0.0708 -0.0720 -0.0687 -0.0677 -0.0607 -0.0446 0.4160 0.5560 -0.0735 -0.0726 -0.0717 -0.0705 -0.0775 -0.0708 -0.0708 -0.0717 -0.0674 -0.0842
 -0.0867 -0.0687 -0.0699 -0.0720 -0.0708 -0.0708 -0.0720 -0.0748 -0.0653 -0.0629 -0.0436 0.6152 0.0015 -0.0763 -0.0711 -0.0781 -0.0720 -0.0696 -0.0696 -0.0714 -0.0821
 -0.0864 -0.0696 -0.0671 -0.0705 -0.0757 -0.0711 -0.0708 -0.0714 -0.0693 -0.0714 -0.0677 -0.0552 0.1242 0.8890 -0.0266 -0.0763 -0.0674 -0.0708 -0.0702 -0.0717 -0.0842
 -0.0842 -0.0684 -0.0668 -0.0677 -0.0708 -0.0693 -0.0684 -0.0699 -0.0696 -0.0690 -0.0690 -0.0677 -0.0650 -0.0494 0.2213 0.2356 -0.0684 -0.0684 -0.0705 -0.0681 -0.0870
 -0.0839 -0.0681 -0.0687 -0.0662 -0.0699 -0.0702 -0.0696 -0.0671 -0.0690 -0.0708 -0.0790 -0.0702 -0.0659 -0.0687 -0.0629 -0.0314 0.7687 0.1627 -0.0684 -0.0693 -0.0867
 -0.0833 -0.0687 -0.0693 -0.0677 -0.0696 -0.0699 -0.0702 -0.0681 -0.0677 -0.0723 -0.0787 -0.0702 -0.0681 -0.0693 -0.0668 -0.0729 -0.0546 0.0003 0.5444 -0.0256 -0.0836
 -0.0848 -0.0671 -0.0665 -0.0693 -0.0681 -0.0699 -0.0693 -0.0705 -0.0690 -0.0702 -0.0830 -0.0690 -0.0693 -0.0711 -0.0681 -0.0769 -0.0687 -0.0677 -0.0476 0.4987 0.2927
 -0.0842 -0.0668 -0.0653 -0.0671 -0.0760 -0.0690 -0.0674 -0.0699 -0.0702 -0.0714 -0.0775 -0.0684 -0.0699 -0.0696 -0.0671 -0.0766 -0.0708 -0.0681 -0.0705 -0.0613 -0.0546
 -0.0830 -0.0674 -0.0671 -0.0650 -0.0705 -0.0656 -0.0681 -0.0714 -0.0717 -0.0668 -0.0705 -0.0693 -0.0693 -0.0693 -0.0705 -0.0748 -0.0702 -0.0684 -0.0693 -0.0690 -0.0821
 -0.0824 -0.0671 -0.0696 -0.0659 -0.0665 -0.0671 -0.0665 -0.0665 -0.0720 -0.0711 -0.0681 -0.0699 -0.0668 -0.0696 -0.0681 -0.0751 -0.0671 -0.0696 -0.0693 -0.0705 -0.0824
 -0.0818 -0.0671 -0.0684 -0.0684 -0.0699 -0.0687 -0.0668 -0.0693 -0.0671 -0.0711 -0.0699 -0.0690 -0.0693 -0.0702 -0.0681 -0.0775 -0.0677 -0.0699 -0.0711 -0.0684 -0.0827
 -0.0839 -0.0665 -0.0690 -0.0690 -0.0668 -0.0674 -0.0671 -0.0690 -0.0644 -0.0690 -0.0818 -0.0662 -0.0696 -0.0708 -0.0690 -0.0760 -0.0690 -0.0696 -0.0684 -0.0699 -0.0806
 -0.0836 -0.0665 -0.0684 -0.0662 -0.0735 -0.0653 -0.0644 -0.0681 -0.0665 -0.0653 -0.0778 -0.0671 -0.0677 -0.0702 -0.0705 -0.0751 -0.0714 -0.0668 -0.0693 -0.0708 -0.0845
 -0.0830 -0.0687 -0.0668 -0.0656 -0.0708 -0.0653 -0.0653 -0.0687 -0.0681 -0.0665 -0.0659 -0.0656 -0.0659 -0.0690 -0.0696 -0.0720 -0.0702 -0.0684 -0.0684 -0.0705 -0.0809
 -0.0809 -0.0693 -0.0674 -0.0684 -0.0659 -0.0677 -0.0665 -0.0681 -0.0668 -0.0668 -0.0644 -0.0681 -0.0668 -0.0681 -0.0656 -0.0729 -0.0668 -0.0693 -0.0665 -0.0684 -0.0827
 -0.0821 -0.0677 -0.0684 -0.0677 -0.0705 -0.0687 -0.0671 -0.0687 -0.0668 -0.0684 -0.0684 -0.0665 -0.0684 -0.0656 -0.0641 -0.0732 -0.0681 -0.0696 -0.0693 -0.0671 -0.0827
 -0.0836 -0.0665 -0.0690 -0.0674 -0.0653 -0.0662 -0.0668 -0.0684 -0.0653 -0.0690 -0.0711 -0.0668 -0.0662 -0.0665 -0.0635 -0.0739 -0.0653 -0.0647 -0.0690 -0.0684 -0.0839
 -0.0839 -0.0677 -0.0677 -0.0656 -0.0659 -0.0650 -0.0656 -0.0714 -0.0674 -0.0665 -0.0699 -0.0662 -0.0656 -0.0674 -0.0656 -0.0726 -0.0671 -0.0656 -0.0693 -0.0687 -0.0821
  817   Tuesday, October 27, 2020, 08:54 Aaron SchmidtNb#9 LP-SISITWTM244508-243515-4In progressNb#9 Conditioning

Tuesday, October 27, 2020, 08:40: Roughing.

Tuesday, October 27, 2020, 09:13: TP1B on.

Tuesday, October 27, 2020, 10:13: TP1A on.

Tuesday, October 27, 2020, 12:59: Vacuum @ 4.55e-06T

Tuesday, October 27, 2020, 13:01: Waterlines opened. Vacuum @ 4.26e-06T.

Tuesday, October 27, 2020, 13:03: Power / sources on.

Tuesday, October 27, 2020, 13:05: Optics on. IV4 open. TGHT / TBHT check ok.


Wednesday, October 28, 2020, 04:30: Auto-ramping TGHT / TBHT  to 350 / 150 A @ 2 A per min. 

Wednesday, October 28, 2020, 06:30:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 26.66 5.67
 TBHT 26.51

8.40

 COIL + EE 26.43 2.59
 TGHT 26.52 6.44

Wednesday, October 28, 2020, 06:42: BIAS / EE / EZL @ 30 / -1.5 / 13 kV.

Wednesday, October 28, 2020, 07:33: Auto-ramping TGHT / TBHT  to 580 / 230 A @ 2 A per min.

Wednesday, October 28, 2020, 13:03:

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 27.25 6.62
 TBHT 26.90 9.27
 COIL + EE 26.68 3.08
 TGHT 26.88 6.85

 


Thursday, October 29, 2020, 15:19: HV to 0 kV. Begin auto-cooling @ 1 A per min.


Large Vacuum spike noted 5:30 approx. Tripped TS.

Monday, November 02, 2020, 08:32: Vacuum @ 2.65e-06T. PS/optics off (Sources already tripped)

Monday, November 02, 2020, 08:33: IV4 closed.

https://elog.triumf.ca/TIS/Test-Stand/818 - Leak Checks (FS#4 confirmed)

Monday, November 02, 2020, 09:27: IG1 off. Turbo pumps off.

Monday, November 02, 2020, 10:38: Venting.

Attachment 1: Nb#9_Conditioning.docx
Attachment 2: ER-580-230-30kV-M133.txt
value (Voltage offset      40.0000)
     75.0000
      1.0000
     95.0000
  29992.6740
21
21
./emit.dat
 -0.1520 -0.1059 -0.1093 -0.0754 0.1788 3.5150 -0.1364 -0.1254 -0.1096 -0.1038 -0.1035 -0.1022 -0.1004 -0.1001 -0.1044 -0.0998 -0.1013 -0.1053 -0.1019 -0.1013 -0.1065
 -0.1144 -0.0998 -0.1108 -0.1163 -0.0986 0.0519 2.7634 1.5201 -0.1227 -0.1068 -0.1019 -0.1010 -0.0974 -0.0955 -0.0980 -0.0980 -0.0937 -0.0980 -0.0998 -0.0961 -0.1001
 -0.1181 -0.0970 -0.0937 -0.0922 -0.1007 -0.0769 -0.0314 0.0897 3.5931 -0.0458 -0.1083 -0.1031 -0.1004 -0.0949 -0.0922 -0.0986 -0.0937 -0.0952 -0.0949 -0.0949 -0.0964
 -0.1147 -0.0998 -0.1013 -0.0967 -0.1016 -0.0986 -0.0995 -0.0986 -0.0104 1.0684 2.4551 -0.0870 -0.1007 -0.1013 -0.0946 -0.0952 -0.0989 -0.0989 -0.0967 -0.0989 -0.0919
 -0.1138 -0.1007 -0.1019 -0.0974 -0.0983 -0.0995 -0.0983 -0.1019 -0.0943 -0.0854 -0.0217 1.3965 0.1556 -0.0983 -0.0986 -0.0949 -0.0986 -0.1013 -0.0980 -0.0961 -0.0964
 -0.1135 -0.0992 -0.0970 -0.0989 -0.0986 -0.0974 -0.0958 -0.0992 -0.0964 -0.0958 -0.0934 -0.0745 0.0818 1.6803 0.0275 -0.0995 -0.0955 -0.0977 -0.0958 -0.0970 -0.1025
 -0.1111 -0.0943 -0.0940 -0.0964 -0.0943 -0.0909 -0.0934 -0.0952 -0.0916 -0.0961 -0.0970 -0.0909 -0.0919 -0.0616 0.0912 0.4849 -0.0873 -0.0949 -0.0974 -0.0934 -0.0998
 -0.1093 -0.0937 -0.0922 -0.0946 -0.0937 -0.0900 -0.0955 -0.0946 -0.0958 -0.0937 -0.0922 -0.0928 -0.0934 -0.0919 -0.0903 -0.0565 0.5252 0.2335 -0.0937 -0.0955 -0.0977
 -0.1038 -0.0888 -0.0922 -0.0925 -0.0943 -0.0937 -0.0946 -0.0943 -0.0943 -0.0955 -0.0922 -0.0925 -0.0940 -0.0952 -0.0912 -0.0974 -0.0839 -0.0626 0.5795 -0.0574 -0.0897
 -0.1022 -0.0858 -0.0876 -0.0937 -0.0946 -0.0955 -0.0946 -0.0949 -0.0940 -0.0946 -0.0958 -0.0946 -0.0952 -0.0943 -0.0952 -0.0970 -0.0946 -0.0955 -0.0797 0.0302 0.2670
 -0.1050 -0.0848 -0.0830 -0.0897 -0.0903 -0.0943 -0.0934 -0.0958 -0.0928 -0.0940 -0.0989 -0.0937 -0.0977 -0.0922 -0.0940 -0.0977 -0.0970 -0.0974 -0.0943 -0.0931 -0.0864
 -0.1053 -0.0864 -0.0821 -0.0854 -0.0873 -0.0885 -0.0922 -0.0937 -0.0943 -0.0946 -0.0992 -0.0897 -0.0967 -0.0946 -0.0980 -0.0958 -0.0946 -0.0940 -0.0946 -0.0946 -0.0928
 -0.1062 -0.0824 -0.0864 -0.0873 -0.0864 -0.0845 -0.0922 -0.0876 -0.0912 -0.0946 -0.0940 -0.0916 -0.0946 -0.0955 -0.0943 -0.0937 -0.0977 -0.0940 -0.0970 -0.0934 -0.0967
 -0.1022 -0.0833 -0.0858 -0.0867 -0.0824 -0.0861 -0.0891 -0.0894 -0.0876 -0.0961 -0.0937 -0.0931 -0.0940 -0.0970 -0.0928 -0.0970 -0.0964 -0.0964 -0.0961 -0.0952 -0.0934
 -0.1044 -0.0858 -0.0864 -0.0900 -0.0848 -0.0888 -0.0861 -0.0903 -0.0870 -0.0912 -0.0964 -0.0909 -0.0955 -0.0946 -0.0958 -0.0961 -0.0928 -0.0977 -0.0934 -0.0928 -0.0970
 -0.1044 -0.0870 -0.0839 -0.0867 -0.0882 -0.0876 -0.0848 -0.0876 -0.0854 -0.0888 -0.0885 -0.0925 -0.0958 -0.0922 -0.0970 -0.0940 -0.0961 -0.0964 -0.0958 -0.0919 -0.1028
 -0.1041 -0.0858 -0.0848 -0.0833 -0.0900 -0.0888 -0.0854 -0.0870 -0.0876 -0.0870 -0.0870 -0.0885 -0.0922 -0.0919 -0.0955 -0.0967 -0.0946 -0.0949 -0.0952 -0.0919 -0.0925
 -0.1062 -0.0848 -0.0870 -0.0842 -0.0900 -0.0861 -0.0861 -0.0854 -0.0922 -0.0864 -0.0952 -0.0876 -0.0916 -0.0906 -0.0912 -0.0961 -0.0934 -0.0949 -0.0952 -0.0912 -0.0992
 -0.1059 -0.0861 -0.0873 -0.0845 -0.0909 -0.0879 -0.0882 -0.0848 -0.0912 -0.0888 -0.0854 -0.0906 -0.0909 -0.0937 -0.0912 -0.0958 -0.0925 -0.0955 -0.0949 -0.0937 -0.0964
 -0.1050 -0.0861 -0.0827 -0.0848 -0.0922 -0.0864 -0.0848 -0.0876 -0.0903 -0.0885 -0.0848 -0.0900 -0.0903 -0.0931 -0.0891 -0.0940 -0.0934 -0.0946 -0.0946 -0.0949 -0.0970
 -0.1010 -0.0858 -0.0824 -0.0867 -0.0897 -0.0891 -0.0851 -0.0882 -0.0882 -0.0867 -0.0897 -0.0870 -0.0928 -0.0891 -0.0922 -0.0894 -0.0916 -0.0946 -0.0922 -0.0931 -0.0986
Attachment 3: ER-580-230-30kV-M23.txt
value (Voltage offset      40.0000)
     75.0000
      1.0000
     95.0000
  29992.6740
21
21
./emit.dat
 -0.1556 -0.1151 -0.0980 -0.1022 -0.0198 0.0833 -0.1035 -0.1001 -0.1001 -0.1025 -0.1016 -0.0986 -0.0958 -0.0995 -0.1019 -0.0970 -0.1007 -0.0995 -0.1007 -0.0992 -0.1028
 -0.1199 -0.1111 -0.0977 -0.1028 -0.0909 -0.0772 0.1352 -0.0201 -0.0970 -0.0946 -0.0937 -0.0974 -0.0958 -0.0912 -0.1001 -0.0934 -0.0912 -0.0937 -0.1004 -0.0970 -0.0995
 -0.1169 -0.0909 -0.0912 -0.0934 -0.0946 -0.0937 -0.0830 -0.0598 0.1181 -0.0879 -0.0873 -0.0958 -0.0952 -0.0894 -0.0916 -0.0955 -0.0891 -0.0946 -0.0928 -0.0958 -0.0964
 -0.1175 -0.0961 -0.0986 -0.0916 -0.0958 -0.0958 -0.0928 -0.0934 -0.0891 0.0388 0.0153 -0.0916 -0.0937 -0.0912 -0.0900 -0.0961 -0.0909 -0.0931 -0.0912 -0.0992 -0.0967
 -0.1175 -0.0940 -0.0989 -0.0940 -0.0946 -0.0958 -0.0946 -0.0934 -0.0934 -0.0946 -0.0815 0.0415 -0.0793 -0.0934 -0.0900 -0.0922 -0.0934 -0.0961 -0.0934 -0.0955 -0.0955
 -0.1190 -0.0934 -0.0980 -0.0952 -0.0922 -0.0970 -0.0964 -0.0940 -0.0961 -0.0961 -0.0906 -0.0897 -0.0519 0.0281 -0.0879 -0.0922 -0.0928 -0.0934 -0.0961 -0.0974 -0.0998
 -0.1163 -0.0925 -0.0958 -0.0952 -0.0931 -0.0952 -0.0943 -0.0949 -0.0946 -0.0949 -0.0992 -0.0916 -0.0928 -0.0882 -0.0555 -0.0568 -0.0922 -0.0919 -0.0980 -0.0961 -0.1016
 -0.1151 -0.0974 -0.0925 -0.0912 -0.0931 -0.0925 -0.0903 -0.0934 -0.0961 -0.0931 -0.0940 -0.0937 -0.0934 -0.0925 -0.0876 -0.0815 -0.0214 -0.0726 -0.0894 -0.0974 -0.1001
 -0.1163 -0.0940 -0.0943 -0.0937 -0.0946 -0.0928 -0.0909 -0.0934 -0.0937 -0.0931 -0.0909 -0.0922 -0.0937 -0.0925 -0.0922 -0.0894 -0.0912 -0.0778 -0.0385 -0.0949 -0.1007
 -0.1151 -0.0937 -0.0964 -0.0964 -0.0943 -0.0961 -0.0922 -0.0952 -0.0934 -0.0940 -0.0928 -0.0909 -0.0931 -0.0934 -0.0937 -0.0928 -0.0925 -0.0934 -0.0897 -0.0684 -0.0696
 -0.1160 -0.0916 -0.0940 -0.0955 -0.0952 -0.0952 -0.0919 -0.0946 -0.0928 -0.0931 -0.0983 -0.0922 -0.0934 -0.0912 -0.0931 -0.0925 -0.0922 -0.0919 -0.0980 -0.0934 -0.0961
 -0.1163 -0.0934 -0.0912 -0.0937 -0.0928 -0.0912 -0.0912 -0.0916 -0.0961 -0.0900 -0.0931 -0.0909 -0.0952 -0.0922 -0.0906 -0.0955 -0.0897 -0.0928 -0.0958 -0.0949 -0.0937
 -0.1151 -0.0940 -0.0922 -0.0934 -0.0940 -0.0919 -0.0916 -0.0925 -0.0949 -0.0922 -0.0931 -0.0919 -0.0949 -0.0922 -0.0906 -0.0970 -0.0919 -0.0900 -0.0931 -0.0958 -0.0974
 -0.1147 -0.0937 -0.0946 -0.0925 -0.0934 -0.0916 -0.0900 -0.0922 -0.0928 -0.0928 -0.1047 -0.0916 -0.0943 -0.0912 -0.0925 -0.0934 -0.0925 -0.0934 -0.0928 -0.0977 -0.0992
 -0.1166 -0.0934 -0.0952 -0.0937 -0.0909 -0.0919 -0.0934 -0.0912 -0.0906 -0.0946 -0.0937 -0.0922 -0.0943 -0.0925 -0.0916 -0.0916 -0.0928 -0.0906 -0.0943 -0.0946 -0.0964
 -0.1184 -0.0922 -0.0928 -0.0934 -0.0906 -0.0919 -0.0922 -0.0912 -0.0916 -0.0934 -0.0931 -0.0882 -0.0925 -0.0919 -0.0928 -0.0909 -0.0916 -0.0916 -0.0977 -0.0925 -0.1025
 -0.1166 -0.0934 -0.0906 -0.0934 -0.0946 -0.0891 -0.0909 -0.0916 -0.0903 -0.0900 -0.0989 -0.0909 -0.0912 -0.0906 -0.0912 -0.0922 -0.0897 -0.0916 -0.0919 -0.0925 -0.0934
 -0.1160 -0.0958 -0.0940 -0.0946 -0.0946 -0.0906 -0.0888 -0.0928 -0.0916 -0.0912 -0.0946 -0.0928 -0.0949 -0.0916 -0.0934 -0.0925 -0.0909 -0.0931 -0.0909 -0.0952 -0.0970
 -0.1154 -0.0937 -0.0934 -0.0955 -0.0934 -0.0928 -0.0906 -0.0919 -0.0925 -0.0916 -0.0888 -0.0928 -0.0940 -0.0897 -0.0922 -0.0919 -0.0934 -0.0940 -0.0967 -0.0937 -0.1010
 -0.1151 -0.0919 -0.0974 -0.0934 -0.0925 -0.0940 -0.0940 -0.0912 -0.0919 -0.0928 -0.0903 -0.0900 -0.0928 -0.0903 -0.0912 -0.0922 -0.0943 -0.0937 -0.0964 -0.0940 -0.0946
 -0.1141 -0.0912 -0.0934 -0.0937 -0.0919 -0.0919 -0.0928 -0.0922 -0.0900 -0.0931 -0.1035 -0.0894 -0.0912 -0.0906 -0.0900 -0.0925 -0.0922 -0.0885 -0.0922 -0.0952 -0.1013
  818   Monday, November 02, 2020, 08:52 Aaron Schmidt      Problems/SolutionsLeak check / Troubleshoot

Monday, November 02, 2020, 08:46:

Large Vacuum spike noted 5:30 approx. Tripped TS. On tail end of the Nb#9 conditioning run. HV & heating were completed last week

Monday, November 02, 2020, 08:47: Vacuum @ 2.66e-06T.

Monday, November 02, 2020, 08:50: Closed and purged all the TS waterlines. Vacuum dropped to 1.31e-06T and continues to drop.

Monday, November 02, 2020, 08:59: Vacuum @ 1.05-06T.

Monday, November 02, 2020, 09:00: FS#5 opened. No response on vacuum.

Monday, November 02, 2020, 09:05: Vacuum @ 1.05e-06T.

Monday, November 02, 2020, 09:07: FS#2 opened. No response on vacuum.

Monday, November 02, 2020, 09:12: Vacuum @ 9.98e-07T.

Monday, November 02, 2020, 09:13: Opened FS#3. No response on vacuum.

Monday, November 02, 2020, 09:19: Vacuum @ 9.96e-07T.

Monday, November 02, 2020, 09:21: Opened FS#4. Immediate vacuum spike noticed. 1.69e-06T and climbing.

Monday, November 02, 2020, 09:26: Closed & purged all the waterlines. Vacuum dropped back down to 9.97e-07T.

Monday, November 02, 2020, 09:27: IG1 off. Turbo pumps off.


Tuesday, November 03, 2020, 10:10: Indium gasket on FS#4 checked w/ sniffer / LD w/ He. ok.

Tuesday, November 03, 2020, 10:30: 120 PSI on line FS#4 feed through (A) Center - TBHT. 0.0E-07 atm-cc/sec.

Tuesday, November 03, 2020, 10:45: LD @ 0.0E-07 atm-cc/sec. Purge the line.

Tuesday, November 03, 2020, 10:51: 120 PSI on line FS#4 feed through (B) Sides - TBHT. 0.0E-07 atm-cc/sec.

Tuesday, November 03, 2020, 11:08: LD @ 0.0E-07 atm-cc/sec. Purge the line.

Tuesday, November 03, 2020, 11:12: 120 PSI on line FS#4 feed through (A) Center - TBHT. 0.0E-07 atm-cc/sec.

Tuesday, November 03, 2020, 11:20: Purge lines. Leak not found w/ LD-Sniffer.

Tuesday, November 03, 2020, 11:30: Roughing.

Tuesday, November 03, 2020, 12:24: TP1B on. 

Tuesday, November 03, 2020, 13:04: TP1A & IG1 on. 

Tuesday, November 03, 2020, 14:26: LD: 0.0E-09 atm-cc/sec. Vacuum @ 1.75e-05T

Tuesday, November 03, 2020, 14:26: Open to the chamber. LD: 2.6E-07 atm-cc/sec. Vacuum @ 1.66e-05T.

Tuesday, November 03, 2020, 14:29: Purged FS#4 w/ HPA.

Tuesday, November 03, 2020, 14:33: LD: 2.5E-07 atm-cc/sec. Vacuum @ 1.59e-05T.

Tuesday, November 03, 2020, 14:38: Connect 120 PSI on line FS#4 feed through (A) Center - TBHT. LD: 2.3E-07 atm-cc/sec. Vacuum @ 1.59e-05T.

Tuesday, November 03, 2020, 14:58: LD: 2.1E-07 atm-cc/sec. Vacuum @ 1.40e-05T. Purge line.

Tuesday, November 03, 2020, 15:02: Connect 120 PSI on line FS#4 feed through (B) Sides - TBHT. 2.2E-07 atm-cc/sec. Vacuum @ 1.31e-05T.

Tuesday, November 03, 2020, 15:22: LD: 2.7E-07 atm-cc/sec. Vacuum @ 1.24e-05T. Purge line.

Tuesday, November 03, 2020, 15:27: Disconnected LD. Disconnected HE. Purged FS#4 w/ HPA. Test again in the morning. FS#4 - B appears to be the source of the leak.


Wednesday, November 04, 2020, 08:35: LD: 0.0E-09 atm-cc/sec. Vacuum @ 2.40e-06T

Wednesday, November 04, 2020, 08:37: Open to the chamber. LD: 1.8E-08 atm-cc/sec. Vacuum @ 2.40e-06T.

Wednesday, November 04, 2020, 08:41: Connect 120 PSI on line FS#4 feed through (A) Center - TBHT. LD: 1.4E-08 atm-cc/sec. Vacuum @ 2.40e-06T.

Wednesday, November 04, 2020, 08:46: LD: 1.4E-08 atm-cc/sec. Vacuum @ 2.40e-06T.

Wednesday, November 04, 2020, 08:51: Connect 120 PSI on line FS#4 feed through (B) Sides - TBHT. 1.5E-08 atm-cc/sec. Vacuum @ 2.40e-06T.

Wednesday, November 04, 2020, 09:01: LD: 3.0E-08 atm-cc/sec. Vacuum @ 2.31e-06T.

Wednesday, November 04, 2020, 09:07: Disconnected LD. Flushed lines w/ HPA. Vacuum @ 2.31e-06T.

Wednesday, November 04, 2020, 09:10: Open FS#2 & FS#3. Vacuum @ 2.33e-06T. Ok.

Wednesday, November 04, 2020, 09:11: Opened FS#4. Vacuum @ 2.42e-06T.

Wednesday, November 04, 2020, 09:18: Vacuum @ 2.42e-06T.

Wednesday, November 04, 2020, 09:19: IG1 & turbo pumps off. Purge waterlines.

Wednesday, November 04, 2020, 10:28: Venting.

Opened / inspected water block (B) and the line. ok. Swap out O-rings w/ new ones w/ vacuum grease.

Wednesday, November 04, 2020, 12:06: Roughing.

Wednesday, November 04, 2020, 12:57: TP1B on. 

Wednesday, November 04, 2020, 13:06: TP1A on. 

Wednesday, November 04, 2020, 13:16: IG1 on. 

Wednesday, November 04, 2020, 15:54: Vacuum @ 4.37e-06T.

Wednesday, November 04, 2020, 15:56: Opened FS#2 & FS#3. Vacuum @ 4.29e-06T. OK.

Wednesday, November 04, 2020, 15:59: Opened FS#4. Vacuum @ 4.29e-06T.

Wednesday, November 04, 2020, 16:12:  Vacuum @ 4.02e-06T & dropping.


Friday, November 06, 2020, 06:02: Vacuum @ 1.34e-06T ok. IG1 off. Turbo pumps off. 

 

 

 

Attachment 1: Nov-2-2020_Leak.docx
  819   Friday, November 06, 2020, 12:53 Aaron SchmidtNb#9LP-SISITWTM244508-243515-4In progressConditioning Nb#9 w/ P/S Target & Bracket

Attached end plate parasitic / symbiotic target & PEEK assembly bracket.

Friday, November 06, 2020, 12:24: Roughing.

Friday, November 06, 2020, 12:53: TP1B on.

Friday, November 06, 2020, 13:05: TP1A on. 

Friday, November 06, 2020, 13:16: IG1 on.


Monday, November 09, 2020, 06:26: Vacuum @ 1.25e-06T.

Monday, November 09, 2020, 06:28: HS waterline opened. Vacuum ok @ 1.25e-06T.

Monday, November 09, 2020, 06:36: Power/sources on.

Monday, November 09, 2020, 06:39: Auto-ramping TGHT / TBHT to 350 / 150 A @ 4 A per min.

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 23.96 5.15
 TBHT 23.78

8.02

 COIL + EE 23.67 2.39
 TGHT 23.77 6.19

Monday, November 09, 2020, 06:4: Optics on.

Monday, November 09, 2020, 08:10: IV4 open.

Monday, November 09, 2020, 08:15: BIAS / EE / EZL @ 30 / -1.5 / 13 kV.

Monday, November 09, 2020, 08:19: Wire & Mass scans @ 350 / 150 A. Ok.

Monday, November 09, 2020, 08:27: Auto-ramping TGHT / TBHT to 580 / 230 A @ 2 A per min.

Monday, November 09, 2020, 11:40: Mass & wire scans complete.

 Device Temp
[C]
 Flow
[lpm]
 HS + MSP 25.27 7.12
 TBHT 24.88

9.73

 COIL + EE 24.65 3.26
 TGHT 24.88 7.05

Monday, November 09, 2020, 13:46: E-rig PS off.


Tuesday, November 10, 2020, 04:47: Auto-cooling @ 2A per min. 

Tuesday, November 10, 2020, 06:21: HV @ 0 V. 

Tuesday, November 10, 2020, 06:58: TBHT @ 0 A. TGHT @ 317 A. Auto-cooling @ 3A per min. 

Tuesday, November 10, 2020, 09:06: IV4 Close. Sources off.

Tuesday, November 10, 2020, 09:07: IG1, power, & Turbo pumps off.

Tuesday, November 10, 2020, 10:15: Waterline purged. Venting.

Attachment 1: Nb#9_Conditioning_with_P-S_Mods.docx
Attachment 2: ITW-TM2-Nb#9-LP-SIS_Test_Stand.docx
Attachment 3: ER-580-230-30kV-m7.txt
value (Voltage offset      40.0000)
     75.0000
      1.0000
     95.0000
  29992.6740
21
21
./emit.dat
 -0.4391 -0.0729 -0.0748 -0.0726 -0.0681 -0.0476 0.0745 -0.0732 -0.0745 -0.0739 -0.0711 -0.0708 -0.0742 -0.0732 -0.0717 -0.0748 -0.0720 -0.0748 -0.0732 -0.0723 -0.0720
 -0.0726 -0.0665 -0.0681 -0.0702 -0.0653 -0.0659 -0.0372 -0.0385 0.0055 -0.0696 -0.0687 -0.0662 -0.0671 -0.0665 -0.0665 -0.0702 -0.0674 -0.0681 -0.0711 -0.0662 -0.0677
 -0.0677 -0.0674 -0.0623 -0.0674 -0.0659 -0.0647 -0.0653 -0.0610 -0.0070 0.0531 -0.0592 -0.0668 -0.0702 -0.0674 -0.0671 -0.0677 -0.0702 -0.0653 -0.0659 -0.0671 -0.0681
 -0.0674 -0.0693 -0.0684 -0.0665 -0.0690 -0.0662 -0.0653 -0.0684 -0.0635 -0.0082 0.0125 0.0644 -0.0684 -0.0668 -0.0681 -0.0671 -0.0662 -0.0693 -0.0662 -0.0677 -0.0665
 -0.0671 -0.0677 -0.0699 -0.0653 -0.0674 -0.0684 -0.0659 -0.0684 -0.0668 -0.0638 -0.0641 0.0488 0.0113 -0.0317 -0.0684 -0.0677 -0.0653 -0.0671 -0.0659 -0.0674 -0.0668
 -0.0693 -0.0659 -0.0665 -0.0677 -0.0671 -0.0674 -0.0677 -0.0671 -0.0668 -0.0668 -0.0638 -0.0623 0.0134 0.1120 0.0012 -0.0674 -0.0665 -0.0690 -0.0684 -0.0671 -0.0693
 -0.0674 -0.0665 -0.0650 -0.0665 -0.0659 -0.0659 -0.0684 -0.0665 -0.0668 -0.0681 -0.0641 -0.0647 -0.0656 -0.0586 0.1199 0.0067 -0.0555 -0.0635 -0.0690 -0.0671 -0.0677
 -0.0662 -0.0668 -0.0638 -0.0662 -0.0668 -0.0671 -0.0668 -0.0668 -0.0653 -0.0653 -0.0681 -0.0671 -0.0650 -0.0665 -0.0616 0.1205 0.1358 -0.0232 -0.0641 -0.0693 -0.0668
 -0.0656 -0.0674 -0.0653 -0.0653 -0.0668 -0.0656 -0.0659 -0.0668 -0.0668 -0.0668 -0.0726 -0.0665 -0.0665 -0.0671 -0.0671 -0.0656 -0.0580 0.3613 -0.0021 -0.0607 -0.0659
 -0.0659 -0.0665 -0.0665 -0.0662 -0.0668 -0.0668 -0.0671 -0.0681 -0.0684 -0.0644 -0.0653 -0.0653 -0.0671 -0.0650 -0.0681 -0.0696 -0.0644 -0.0613 0.1016 0.2005 -0.0372
 -0.0671 -0.0641 -0.0671 -0.0659 -0.0662 -0.0659 -0.0662 -0.0665 -0.0668 -0.0650 -0.0650 -0.0647 -0.0690 -0.0662 -0.0662 -0.0702 -0.0650 -0.0662 -0.0681 -0.0555 0.3531
 -0.0693 -0.0644 -0.0659 -0.0662 -0.0647 -0.0647 -0.0668 -0.0656 -0.0656 -0.0677 -0.0665 -0.0647 -0.0668 -0.0684 -0.0653 -0.0687 -0.0668 -0.0638 -0.0659 -0.0662 -0.0598
 -0.0665 -0.0659 -0.0641 -0.0674 -0.0656 -0.0641 -0.0665 -0.0671 -0.0635 -0.0671 -0.0809 -0.0662 -0.0659 -0.0677 -0.0674 -0.0677 -0.0677 -0.0656 -0.0650 -0.0687 -0.0650
 -0.0659 -0.0674 -0.0641 -0.0662 -0.0668 -0.0662 -0.0662 -0.0671 -0.0668 -0.0650 -0.0690 -0.0671 -0.0671 -0.0659 -0.0693 -0.0684 -0.0650 -0.0677 -0.0653 -0.0671 -0.0668
 -0.0662 -0.0644 -0.0653 -0.0653 -0.0674 -0.0656 -0.0659 -0.0674 -0.0665 -0.0650 -0.0635 -0.0656 -0.0677 -0.0647 -0.0665 -0.0684 -0.0653 -0.0665 -0.0674 -0.0665 -0.0681
 -0.0653 -0.0635 -0.0641 -0.0644 -0.0653 -0.0653 -0.0647 -0.0656 -0.0668 -0.0641 -0.0717 -0.0635 -0.0668 -0.0668 -0.0650 -0.0681 -0.0662 -0.0668 -0.0671 -0.0647 -0.0696
 -0.0659 -0.0650 -0.0641 -0.0650 -0.0650 -0.0647 -0.0653 -0.0638 -0.0656 -0.0662 -0.0665 -0.0638 -0.0641 -0.0681 -0.0659 -0.0671 -0.0653 -0.0659 -0.0668 -0.0659 -0.0644
 -0.0653 -0.0681 -0.0641 -0.0665 -0.0647 -0.0650 -0.0665 -0.0647 -0.0632 -0.0656 -0.0690 -0.0656 -0.0644 -0.0656 -0.0659 -0.0656 -0.0665 -0.0656 -0.0650 -0.0662 -0.0671
 -0.0650 -0.0662 -0.0650 -0.0647 -0.0659 -0.0644 -0.0677 -0.0632 -0.0656 -0.0641 -0.0726 -0.0656 -0.0662 -0.0647 -0.0650 -0.0647 -0.0662 -0.0665 -0.0650 -0.0659 -0.0632
 -0.0653 -0.0650 -0.0671 -0.0647 -0.0653 -0.0653 -0.0659 -0.0653 -0.0662 -0.0650 -0.0656 -0.0647 -0.0677 -0.0635 -0.0650 -0.0650 -0.0650 -0.0662 -0.0665 -0.0662 -0.0708
 -0.0662 -0.0641 -0.0671 -0.0653 -0.0650 -0.0665 -0.0656 -0.0653 -0.0653 -0.0653 -0.0693 -0.0644 -0.0677 -0.0665 -0.0647 -0.0644 -0.0616 -0.0641 -0.0653 -0.0653 -0.0659
Attachment 4: ER-580-230-30kV-m23.txt
value (Voltage offset      40.0000)
     75.0000
      1.0000
     95.0000
  29992.6740
21
21
./emit.dat
 -0.1184 -0.0726 -0.0748 -0.0739 -0.0665 -0.0098 0.4160 -0.0528 -0.0757 -0.0742 -0.0705 -0.0726 -0.0742 -0.0708 -0.0745 -0.0720 -0.0757 -0.0729 -0.0696 -0.0726 -0.0739
 -0.0833 -0.0668 -0.0671 -0.0708 -0.0674 -0.0629 -0.0064 0.0250 0.6058 -0.0726 -0.0677 -0.0690 -0.0696 -0.0668 -0.0674 -0.0714 -0.0690 -0.0668 -0.0681 -0.0668 -0.0677
 -0.0812 -0.0681 -0.0623 -0.0659 -0.0665 -0.0644 -0.0620 -0.0452 0.0226 0.3262 0.1285 -0.0690 -0.0696 -0.0690 -0.0647 -0.0699 -0.0659 -0.0671 -0.0693 -0.0638 -0.0684
 -0.0800 -0.0681 -0.0684 -0.0659 -0.0653 -0.0659 -0.0656 -0.0656 -0.0632 0.0967 0.1154 0.4950 -0.0711 -0.0714 -0.0656 -0.0665 -0.0665 -0.0677 -0.0671 -0.0671 -0.0610
 -0.0821 -0.0650 -0.0693 -0.0659 -0.0659 -0.0684 -0.0662 -0.0650 -0.0665 -0.0644 -0.0558 0.1425 0.3867 0.4593 -0.0708 -0.0684 -0.0684 -0.0684 -0.0665 -0.0671 -0.0677
 -0.0818 -0.0644 -0.0665 -0.0684 -0.0656 -0.0677 -0.0677 -0.0644 -0.0656 -0.0653 -0.0629 -0.0598 0.0980 0.3656 0.4013 -0.0665 -0.0671 -0.0677 -0.0641 -0.0668 -0.0684
 -0.0809 -0.0656 -0.0644 -0.0665 -0.0653 -0.0641 -0.0656 -0.0665 -0.0647 -0.0662 -0.0632 -0.0632 -0.0610 -0.0507 0.2103 0.5615 0.5499 -0.0650 -0.0653 -0.0653 -0.0662
 -0.0806 -0.0671 -0.0647 -0.0656 -0.0656 -0.0653 -0.0650 -0.0656 -0.0647 -0.0656 -0.0653 -0.0638 -0.0641 -0.0638 -0.0580 0.0217 0.4376 0.2274 0.0256 -0.0638 -0.0653
 -0.0778 -0.0665 -0.0659 -0.0653 -0.0665 -0.0656 -0.0650 -0.0650 -0.0659 -0.0644 -0.0641 -0.0662 -0.0632 -0.0659 -0.0632 -0.0623 -0.0531 0.1212 0.2921 0.0949 -0.0632
 -0.0800 -0.0659 -0.0674 -0.0656 -0.0662 -0.0659 -0.0641 -0.0641 -0.0668 -0.0668 -0.0632 -0.0668 -0.0650 -0.0671 -0.0638 -0.0635 -0.0668 -0.0616 -0.0464 0.3259 0.0589
 -0.0812 -0.0653 -0.0653 -0.0659 -0.0641 -0.0647 -0.0644 -0.0650 -0.0668 -0.0671 -0.0641 -0.0653 -0.0659 -0.0647 -0.0653 -0.0635 -0.0638 -0.0665 -0.0635 -0.0592 0.0275
 -0.0815 -0.0641 -0.0635 -0.0647 -0.0647 -0.0641 -0.0641 -0.0647 -0.0632 -0.0656 -0.0650 -0.0641 -0.0671 -0.0632 -0.0647 -0.0644 -0.0644 -0.0671 -0.0641 -0.0638 -0.0647
 -0.0797 -0.0659 -0.0647 -0.0656 -0.0632 -0.0629 -0.0644 -0.0632 -0.0635 -0.0659 -0.0671 -0.0629 -0.0656 -0.0681 -0.0653 -0.0644 -0.0644 -0.0665 -0.0656 -0.0656 -0.0647
 -0.0793 -0.0653 -0.0650 -0.0647 -0.0650 -0.0644 -0.0629 -0.0620 -0.0635 -0.0638 -0.0647 -0.0656 -0.0662 -0.0659 -0.0659 -0.0668 -0.0659 -0.0659 -0.0671 -0.0671 -0.0647
 -0.0806 -0.0641 -0.0656 -0.0653 -0.0647 -0.0644 -0.0616 -0.0635 -0.0638 -0.0604 -0.0613 -0.0644 -0.0668 -0.0668 -0.0662 -0.0665 -0.0677 -0.0644 -0.0662 -0.0665 -0.0656
 -0.0803 -0.0632 -0.0644 -0.0653 -0.0610 -0.0632 -0.0638 -0.0620 -0.0613 -0.0644 -0.0626 -0.0638 -0.0656 -0.0641 -0.0653 -0.0647 -0.0668 -0.0641 -0.0665 -0.0653 -0.0684
 -0.0824 -0.0656 -0.0641 -0.0647 -0.0641 -0.0641 -0.0635 -0.0647 -0.0623 -0.0632 -0.0626 -0.0610 -0.0638 -0.0629 -0.0641 -0.0650 -0.0656 -0.0665 -0.0629 -0.0638 -0.0638
 -0.0793 -0.0662 -0.0644 -0.0665 -0.0656 -0.0632 -0.0644 -0.0644 -0.0626 -0.0632 -0.0647 -0.0616 -0.0623 -0.0616 -0.0620 -0.0662 -0.0671 -0.0668 -0.0656 -0.0626 -0.0684
 -0.0775 -0.0644 -0.0647 -0.0644 -0.0659 -0.0629 -0.0620 -0.0635 -0.0635 -0.0620 -0.0659 -0.0626 -0.0632 -0.0595 -0.0604 -0.0644 -0.0653 -0.0647 -0.0668 -0.0644 -0.0650
 -0.0800 -0.0647 -0.0665 -0.0653 -0.0626 -0.0641 -0.0620 -0.0641 -0.0620 -0.0620 -0.0623 -0.0647 -0.0629 -0.0620 -0.0604 -0.0620 -0.0620 -0.0613 -0.0653 -0.0650 -0.0653
 -0.0797 -0.0641 -0.0659 -0.0656 -0.0626 -0.0632 -0.0632 -0.0638 -0.0616 -0.0650 -0.0653 -0.0635 -0.0623 -0.0601 -0.0607 -0.0595 -0.0623 -0.0601 -0.0638 -0.0644 -0.0681
Attachment 5: ER-580-230-30kV-m39.txt
value (Voltage offset      40.0000)
     75.0000
      1.0000
     95.0000
  29978.0220
21
21
./emit.dat
 -0.1260 -0.0723 -0.0952 -0.0980 -0.0671 -0.0824 -0.0494 -0.0656 -0.0723 -0.0754 -0.0720 -0.0717 -0.0739 -0.0726 -0.0720 -0.0787 -0.0739 -0.0757 -0.0754 -0.0723 -0.0726
 -0.0940 -0.0674 -0.0928 -0.0946 -0.0662 -0.0870 -0.0662 -0.0473 -0.0058 -0.0684 -0.0671 -0.0690 -0.0677 -0.0665 -0.0684 -0.0732 -0.0677 -0.0696 -0.0711 -0.0635 -0.0677
 -0.0922 -0.0632 -0.0552 -0.0656 -0.0671 -0.0571 -0.0574 -0.0476 -0.0510 -0.0211 -0.0436 -0.0687 -0.0653 -0.0671 -0.0659 -0.0729 -0.0677 -0.0653 -0.0629 -0.0653 -0.0647
 -0.0900 -0.0671 -0.0665 -0.0610 -0.0665 -0.0644 -0.0656 -0.0662 -0.0668 0.0046 -0.0204 -0.0067 -0.0674 -0.0674 -0.0684 -0.0729 -0.0656 -0.0690 -0.0668 -0.0674 -0.0647
 -0.0894 -0.0668 -0.0665 -0.0641 -0.0656 -0.0671 -0.0659 -0.0656 -0.0671 -0.0653 -0.0742 -0.0162 0.0131 -0.0146 -0.0684 -0.0726 -0.0690 -0.0681 -0.0638 -0.0668 -0.0665
 -0.0900 -0.0656 -0.0674 -0.0638 -0.0653 -0.0665 -0.0659 -0.0620 -0.0693 -0.0665 -0.0650 -0.0653 -0.0415 0.0394 0.0021 -0.0739 -0.0699 -0.0638 -0.0711 -0.0641 -0.0690
 -0.0919 -0.0641 -0.0659 -0.0662 -0.0644 -0.0635 -0.0671 -0.0665 -0.0696 -0.0635 -0.0647 -0.0632 -0.0635 -0.0638 -0.0281 0.0723 -0.0082 -0.0677 -0.0644 -0.0665 -0.0647
 -0.0912 -0.0662 -0.0629 -0.0677 -0.0656 -0.0638 -0.0659 -0.0662 -0.0699 -0.0656 -0.0647 -0.0656 -0.0653 -0.0638 -0.0638 -0.0595 0.0208 0.0162 -0.0330 -0.0665 -0.0641
 -0.0894 -0.0656 -0.0644 -0.0760 -0.0650 -0.0659 -0.0632 -0.0644 -0.0677 -0.0653 -0.0693 -0.0662 -0.0671 -0.0635 -0.0662 -0.0720 -0.0635 -0.0397 0.0357 0.0061 -0.0629
 -0.0903 -0.0653 -0.0650 -0.0671 -0.0681 -0.0681 -0.0644 -0.0647 -0.0687 -0.0668 -0.0650 -0.0653 -0.0684 -0.0656 -0.0647 -0.0735 -0.0681 -0.0635 -0.0629 0.0140 -0.0177
 -0.0916 -0.0638 -0.0671 -0.0656 -0.0638 -0.0641 -0.0650 -0.0641 -0.0696 -0.0668 -0.0635 -0.0647 -0.0674 -0.0656 -0.0644 -0.0729 -0.0674 -0.0650 -0.0671 -0.0626 -0.0531
 -0.0906 -0.0653 -0.0647 -0.0671 -0.0641 -0.0629 -0.0668 -0.0644 -0.0690 -0.0635 -0.0668 -0.0659 -0.0659 -0.0665 -0.0650 -0.0711 -0.0677 -0.0650 -0.0638 -0.0650 -0.0629
 -0.0906 -0.0656 -0.0635 -0.0684 -0.0671 -0.0653 -0.0650 -0.0665 -0.0690 -0.0650 -0.0659 -0.0659 -0.0671 -0.0656 -0.0656 -0.0726 -0.0696 -0.0659 -0.0647 -0.0668 -0.0638
 -0.0891 -0.0668 -0.0656 -0.0696 -0.0659 -0.0665 -0.0638 -0.0644 -0.0693 -0.0644 -0.0647 -0.0653 -0.0684 -0.0665 -0.0662 -0.0732 -0.0647 -0.0653 -0.0653 -0.0668 -0.0653
 -0.0873 -0.0644 -0.0653 -0.0681 -0.0641 -0.0647 -0.0632 -0.0629 -0.0665 -0.0653 -0.0641 -0.0671 -0.0671 -0.0644 -0.0647 -0.0748 -0.0659 -0.0677 -0.0681 -0.0650 -0.0665
 -0.0909 -0.0635 -0.0638 -0.0711 -0.0644 -0.0626 -0.0644 -0.0623 -0.0668 -0.0647 -0.0699 -0.0635 -0.0665 -0.0656 -0.0653 -0.0726 -0.0711 -0.0626 -0.0641 -0.0647 -0.0659
 -0.0912 -0.0629 -0.0641 -0.0699 -0.0650 -0.0635 -0.0644 -0.0650 -0.0665 -0.0632 -0.0674 -0.0656 -0.0647 -0.0650 -0.0656 -0.0699 -0.0668 -0.0653 -0.0647 -0.0653 -0.0635
 -0.0903 -0.0653 -0.0644 -0.0650 -0.0656 -0.0647 -0.0638 -0.0653 -0.0687 -0.0653 -0.0641 -0.0644 -0.0659 -0.0629 -0.0629 -0.0723 -0.0674 -0.0659 -0.0641 -0.0665 -0.0650
 -0.0900 -0.0659 -0.0647 -0.0644 -0.0659 -0.0650 -0.0641 -0.0650 -0.0687 -0.0644 -0.0620 -0.0647 -0.0659 -0.0635 -0.0653 -0.0729 -0.0650 -0.0653 -0.0650 -0.0647 -0.0668
 -0.0879 -0.0638 -0.0653 -0.0635 -0.0659 -0.0641 -0.0629 -0.0641 -0.0668 -0.0656 -0.0644 -0.0647 -0.0674 -0.0644 -0.0647 -0.0723 -0.0653 -0.0626 -0.0653 -0.0641 -0.0665
 -0.0888 -0.0650 -0.0653 -0.0650 -0.0650 -0.0641 -0.0638 -0.0629 -0.0671 -0.0638 -0.0659 -0.0623 -0.0659 -0.0647 -0.0641 -0.0720 -0.0671 -0.0638 -0.0656 -0.0635 -0.0656
Attachment 6: ER-580-230-30kV-m83.txt
value (Voltage offset      40.0000)
     75.0000
      1.0000
     95.0000
  29978.0220
21
21
./emit.dat
 -0.1279 -0.0717 -0.0824 -0.0882 -0.0677 -0.0760 -0.0217 -0.0659 -0.0729 -0.0739 -0.0708 -0.0739 -0.0717 -0.0708 -0.0739 -0.0729 -0.0732 -0.0699 -0.0739 -0.0732 -0.0723
 -0.0919 -0.0665 -0.0751 -0.0842 -0.0653 -0.0784 -0.0482 -0.0558 0.0061 -0.0702 -0.0656 -0.0674 -0.0693 -0.0677 -0.0662 -0.0693 -0.0674 -0.0668 -0.0693 -0.0665 -0.0696
 -0.0928 -0.0656 -0.0607 -0.0629 -0.0659 -0.0607 -0.0632 -0.0580 -0.0476 -0.0253 -0.0375 -0.0644 -0.0684 -0.0665 -0.0641 -0.0668 -0.0671 -0.0647 -0.0684 -0.0659 -0.0681
 -0.0919 -0.0681 -0.0668 -0.0662 -0.0677 -0.0668 -0.0668 -0.0687 -0.0638 -0.0229 -0.0369 -0.0064 -0.0668 -0.0690 -0.0696 -0.0638 -0.0677 -0.0702 -0.0656 -0.0659 -0.0659
 -0.0897 -0.0662 -0.0677 -0.0659 -0.0690 -0.0671 -0.0671 -0.0662 -0.0668 -0.0653 -0.0650 -0.0278 -0.0107 -0.0076 -0.0717 -0.0668 -0.0644 -0.0662 -0.0674 -0.0653 -0.0684
 -0.0912 -0.0653 -0.0693 -0.0665 -0.0641 -0.0681 -0.0659 -0.0650 -0.0690 -0.0653 -0.0632 -0.0662 -0.0473 0.0143 -0.0143 -0.0681 -0.0662 -0.0671 -0.0668 -0.0659 -0.0662
 -0.0922 -0.0659 -0.0677 -0.0662 -0.0641 -0.0656 -0.0668 -0.0653 -0.0656 -0.0671 -0.0659 -0.0656 -0.0668 -0.0638 -0.0357 0.0327 -0.0076 -0.0613 -0.0671 -0.0650 -0.0671
 -0.0928 -0.0653 -0.0650 -0.0665 -0.0650 -0.0653 -0.0659 -0.0684 -0.0662 -0.0671 -0.0677 -0.0647 -0.0656 -0.0671 -0.0641 -0.0568 -0.0012 -0.0082 -0.0247 -0.0671 -0.0662
 -0.0903 -0.0665 -0.0647 -0.0650 -0.0684 -0.0653 -0.0656 -0.0674 -0.0653 -0.0684 -0.0656 -0.0632 -0.0665 -0.0656 -0.0668 -0.0644 -0.0665 -0.0473 0.0046 -0.0098 -0.0653
 -0.0916 -0.0659 -0.0665 -0.0653 -0.0668 -0.0650 -0.0644 -0.0677 -0.0696 -0.0659 -0.0641 -0.0671 -0.0665 -0.0653 -0.0662 -0.0674 -0.0641 -0.0656 -0.0635 -0.0085 -0.0427
 -0.0925 -0.0644 -0.0674 -0.0674 -0.0641 -0.0659 -0.0653 -0.0656 -0.0690 -0.0665 -0.0653 -0.0668 -0.0677 -0.0659 -0.0641 -0.0696 -0.0653 -0.0629 -0.0674 -0.0641 -0.0595
 -0.0922 -0.0662 -0.0659 -0.0650 -0.0629 -0.0647 -0.0665 -0.0644 -0.0677 -0.0671 -0.0650 -0.0653 -0.0677 -0.0677 -0.0647 -0.0665 -0.0668 -0.0629 -0.0668 -0.0632 -0.0632
 -0.0925 -0.0671 -0.0659 -0.0665 -0.0653 -0.0668 -0.0668 -0.0677 -0.0647 -0.0668 -0.0656 -0.0647 -0.0665 -0.0674 -0.0677 -0.0644 -0.0653 -0.0653 -0.0635 -0.0681 -0.0647
 -0.0912 -0.0650 -0.0653 -0.0665 -0.0659 -0.0659 -0.0656 -0.0681 -0.0659 -0.0650 -0.0653 -0.0662 -0.0668 -0.0653 -0.0684 -0.0650 -0.0659 -0.0647 -0.0665 -0.0659 -0.0681
 -0.0897 -0.0653 -0.0671 -0.0662 -0.0650 -0.0659 -0.0659 -0.0656 -0.0677 -0.0632 -0.0653 -0.0671 -0.0659 -0.0641 -0.0659 -0.0681 -0.0638 -0.0659 -0.0668 -0.0641 -0.0662
 -0.0909 -0.0638 -0.0653 -0.0662 -0.0650 -0.0659 -0.0650 -0.0656 -0.0665 -0.0668 -0.0644 -0.0659 -0.0681 -0.0656 -0.0650 -0.0674 -0.0659 -0.0641 -0.0668 -0.0662 -0.0659
 -0.0925 -0.0653 -0.0665 -0.0656 -0.0653 -0.0641 -0.0665 -0.0674 -0.0662 -0.0659 -0.0656 -0.0638 -0.0674 -0.0671 -0.0653 -0.0659 -0.0671 -0.0638 -0.0647 -0.0677 -0.0653
 -0.0912 -0.0671 -0.0671 -0.0677 -0.0653 -0.0641 -0.0668 -0.0677 -0.0641 -0.0653 -0.0677 -0.0647 -0.0659 -0.0656 -0.0668 -0.0629 -0.0659 -0.0653 -0.0647 -0.0656 -0.0644
 -0.0912 -0.0656 -0.0665 -0.0659 -0.0668 -0.0623 -0.0650 -0.0659 -0.0659 -0.0650 -0.0659 -0.0641 -0.0653 -0.0644 -0.0665 -0.0653 -0.0668 -0.0662 -0.0674 -0.0641 -0.0681
 -0.0888 -0.0638 -0.0677 -0.0647 -0.0668 -0.0632 -0.0668 -0.0665 -0.0674 -0.0647 -0.0665 -0.0653 -0.0662 -0.0659 -0.0659 -0.0671 -0.0641 -0.0641 -0.0659 -0.0638 -0.0653
 -0.0888 -0.0647 -0.0681 -0.0653 -0.0647 -0.0647 -0.0677 -0.0671 -0.0656 -0.0668 -0.0647 -0.0665 -0.0653 -0.0653 -0.0650 -0.0656 -0.0647 -0.0644 -0.0671 -0.0662 -0.0641
Attachment 7: ER-580-230-30kV-m133.txt
value (Voltage offset      40.0000)
     75.0000
      1.0000
     95.0000
  29992.6740
21
21
./emit.dat
 -0.1315 -0.0809 -0.1004 -0.0989 -0.0903 -0.0275 -0.0366 -0.0729 -0.0900 -0.0940 -0.0726 -0.0717 -0.0888 -0.0751 -0.0748 -0.0803 -0.0772 -0.0723 -0.0735 -0.0705 -0.0742
 -0.0949 -0.0729 -0.0952 -0.0937 -0.0864 -0.0900 -0.0555 0.0009 0.0299 -0.0858 -0.0653 -0.0702 -0.0827 -0.0684 -0.0705 -0.0769 -0.0687 -0.0653 -0.0684 -0.0644 -0.0693
 -0.0928 -0.0635 -0.0540 -0.0797 -0.0833 -0.0665 -0.0583 -0.0525 -0.0235 -0.0253 -0.0089 -0.0690 -0.0845 -0.0632 -0.0647 -0.0775 -0.0705 -0.0647 -0.0665 -0.0671 -0.0662
 -0.0922 -0.0656 -0.0668 -0.0766 -0.0656 -0.0638 -0.0671 -0.0656 -0.0848 -0.0418 0.0519 0.0247 -0.0854 -0.0681 -0.0644 -0.0748 -0.0705 -0.0684 -0.0641 -0.0677 -0.0674
 -0.0946 -0.0650 -0.0641 -0.0778 -0.0671 -0.0665 -0.0671 -0.0641 -0.0854 -0.0769 -0.0684 -0.0214 0.0305 0.0320 -0.0690 -0.0742 -0.0714 -0.0671 -0.0650 -0.0671 -0.0681
 -0.0961 -0.0644 -0.0650 -0.0757 -0.0702 -0.0665 -0.0659 -0.0668 -0.0839 -0.0760 -0.0641 -0.0626 -0.0708 0.0586 0.0272 -0.0714 -0.0693 -0.0659 -0.0671 -0.0641 -0.0699
 -0.0928 -0.0674 -0.0659 -0.0653 -0.0687 -0.0662 -0.0644 -0.0677 -0.0854 -0.0735 -0.0656 -0.0653 -0.0827 -0.0616 -0.0449 0.1215 0.0116 -0.0616 -0.0662 -0.0644 -0.0690
 -0.0912 -0.0653 -0.0650 -0.0644 -0.0748 -0.0668 -0.0638 -0.0644 -0.0842 -0.0723 -0.0665 -0.0650 -0.0812 -0.0632 -0.0629 -0.0659 0.0104 0.0681 -0.0085 -0.0656 -0.0662
 -0.0928 -0.0656 -0.0656 -0.0650 -0.0693 -0.0668 -0.0656 -0.0647 -0.0864 -0.0729 -0.0647 -0.0650 -0.0818 -0.0638 -0.0629 -0.0742 -0.0677 -0.0516 0.0995 0.0061 -0.0650
 -0.0928 -0.0638 -0.0665 -0.0674 -0.0699 -0.0653 -0.0662 -0.0650 -0.0864 -0.0742 -0.0644 -0.0647 -0.0839 -0.0659 -0.0644 -0.0742 -0.0674 -0.0659 -0.0613 -0.0168 0.0327
 -0.0925 -0.0644 -0.0644 -0.0659 -0.0693 -0.0638 -0.0656 -0.0662 -0.0839 -0.0726 -0.0650 -0.0644 -0.0827 -0.0656 -0.0665 -0.0739 -0.0662 -0.0635 -0.0656 -0.0629 -0.0620
 -0.0922 -0.0650 -0.0650 -0.0644 -0.0696 -0.0650 -0.0644 -0.0653 -0.0864 -0.0714 -0.0671 -0.0647 -0.0818 -0.0659 -0.0650 -0.0751 -0.0690 -0.0647 -0.0662 -0.0641 -0.0656
 -0.0919 -0.0671 -0.0677 -0.0653 -0.0671 -0.0668 -0.0641 -0.0653 -0.0858 -0.0735 -0.0647 -0.0638 -0.0836 -0.0650 -0.0635 -0.0754 -0.0681 -0.0656 -0.0681 -0.0674 -0.0671
 -0.0934 -0.0650 -0.0656 -0.0650 -0.0662 -0.0656 -0.0653 -0.0638 -0.0848 -0.0720 -0.0641 -0.0674 -0.0833 -0.0671 -0.0635 -0.0745 -0.0696 -0.0656 -0.0632 -0.0656 -0.0677
 -0.0946 -0.0644 -0.0638 -0.0653 -0.0668 -0.0641 -0.0656 -0.0632 -0.0848 -0.0732 -0.0623 -0.0620 -0.0836 -0.0638 -0.0662 -0.0732 -0.0693 -0.0653 -0.0684 -0.0632 -0.0708
 -0.0916 -0.0638 -0.0644 -0.0641 -0.0677 -0.0620 -0.0647 -0.0641 -0.0824 -0.0717 -0.0653 -0.0641 -0.0824 -0.0644 -0.0668 -0.0745 -0.0641 -0.0653 -0.0668 -0.0653 -0.0659
 -0.0916 -0.0656 -0.0650 -0.0647 -0.0668 -0.0641 -0.0632 -0.0647 -0.0848 -0.0705 -0.0656 -0.0635 -0.0818 -0.0656 -0.0653 -0.0735 -0.0650 -0.0629 -0.0677 -0.0662 -0.0653
 -0.0897 -0.0659 -0.0653 -0.0653 -0.0668 -0.0668 -0.0635 -0.0647 -0.0845 -0.0693 -0.0641 -0.0629 -0.0815 -0.0641 -0.0641 -0.0757 -0.0668 -0.0647 -0.0653 -0.0668 -0.0665
 -0.0922 -0.0635 -0.0656 -0.0656 -0.0644 -0.0656 -0.0647 -0.0635 -0.0851 -0.0717 -0.0620 -0.0647 -0.0836 -0.0659 -0.0647 -0.0757 -0.0665 -0.0635 -0.0653 -0.0644 -0.0668
 -0.0931 -0.0650 -0.0626 -0.0638 -0.0696 -0.0629 -0.0641 -0.0632 -0.0845 -0.0714 -0.0635 -0.0626 -0.0833 -0.0650 -0.0644 -0.0745 -0.0659 -0.0635 -0.0656 -0.0653 -0.0681
 -0.0925 -0.0647 -0.0635 -0.0638 -0.0653 -0.0632 -0.0653 -0.0653 -0.0812 -0.0720 -0.0656 -0.0641 -0.0815 -0.0629 -0.0638 -0.0720 -0.0659 -0.0659 -0.0650 -0.0641 -0.0668
  820   Tuesday, November 10, 2020, 12:13 Aaron Schmidt    43044-1344378-1In progressPump down empty chamber / Leak.

U-Loop installed on FS#5

Tuesday, November 10, 2020, 12:13: Roughing.

Tuesday, November 10, 2020, 12:57: TP1B on


TS Tripped Thursday am. Leak noted Thursday am remotely. Control room noted water in the chamber.

Friday, November 13, 2020, 06:40: Confirmed. Cleanup

Friday, November 13, 2020, 08:30: FS#4 TBHT (A). Visible water dripping out from the water block. Line (A) removed.

Friday, November 13, 2020, 10:25 Set up Fan. Clean.

Removed, cleaned & leak checked (A) & (B).

(A) leaks at seat and solder

(B) OK.

Closed ballast on RP1. Lines stable.

Friday, November 13, 2020, 12:51: TS chamber to continue to air dry over the weekend.


Monday, November 16, 2020, 09:00: TBHT (B) line is installed. (A) blanked off. Roughing BV1A open.

Monday, November 16, 2020, 09:07: BV1B opened.

Monday, November 16, 2020, 11:41: Vacuum @ 1.965T. Open RP1 ballast. W/ Filter cap

Monday, November 16, 2020, 11:49: Vacuum @ 1.170 and dropping.


Wednesday, November 18, 2020, 10:16: Vacuum At 0.201T. Venting. 

TBHT line (A) repaired and leak checked. Installed in TS. HS w/ horizontal tube oven installed for out gassing.

HS: 44378-1 (SIS Config)

Oven: 43044-13

Wednesday, November 18, 2020, 14:02: Roughing.

Wednesday, November 18, 2020, 14:45: TP1B on. 

Wednesday, November 18, 2020, 15:54: TP1A on. 

Wednesday, November 18, 2020, 16:03: IG1 on. 

Wednesday, November 18, 2020, 19:05: Power bump shut down TS. Controls in whiteout. Restart attempt

Wednesday, November 18, 2020, 19:29: TP1B on. 

Wednesday, November 18, 2020, 20:22: TP1A on. 

Wednesday, November 18, 2020, 20:31: IG1 on 


Thursday, November 19, 2020, 11:57: Vacuum @ 3.32e-06T.

Thursday, November 19, 2020, 11:58: Opened FS#2, FS#3 & FS#5. Vacuum ok

Thursday, November 19, 2020, 12:01: Opened FS#4..

Thursday, November 19, 2020, 12:03: Vacuum ok @ 3.32e-06T.

Thursday, November 19, 2020, 12:07: Power / sources on.

Thursday, November 19, 2020, 12:08: Restarted IOC/PLC.

Thursday, November 19, 2020, 12:13: Auto-ramping TGHT to 200 A @ 1 A per min.

Thursday, November 19, 2020, 15:58: Auto-ramping TGHT to 350 A @ 1 A per min. 

Thursday, November 19, 2020, 17:35: Bypass TMS:PV1 open/close. leave as is. remove Bypasses. 


Friday, November 20, 2020, 07:35: Auto-ramping TGHT to 580 A @ 1 A per min. 


Saturday, November 21, 2020, 12:32: Check. Vacuum @ 4.13e-06T . TGHT @ 494 A. 


Monday, November 23, 2020, 09:53: Check. Vacuum @ 2.97e-06T . TGHT @ 580 A.

On the beamline side:

https://elog.triumf.ca/TIS/Test-Stand/821

Monday, November 23, 2020, 14:03: Check. Vacuum @ 2.73e-06T . TGHT @ 580 A.


Tuesday, November 24, 2020, 12:58: Auto-cooling @ 0.5 A per min. 


Wednesday, November 25, 2020, 09:30: Sources/power off. IG1 & Turbo pumps off.

ELOG V2.9.2-2455