Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production, Page 3 of 8  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Author Target/No.# Source Station Module Target Oven W.O# Heat Shield W.O#down Status Subject Text Attachments
  20   Monday, February 20, 2012, 16:39 John WongUO2/Nb #1LP-FEBIADITETM438481-9 Spenttarget ready for assembly Monday, February 20, 2012, 16:25
Mass of empty target oven used =
461.55g
  
  26   Wednesday, August 01, 2012, 09:37 Pierre BricaultITE-TM4-UO#3LP-FEBIADITETM4  Problems/SolutionsShort has developed while lowering the cathode heater On tuesday July we lower the cathode
heater to swap the anode-cathode bias. While
lowering the cathode heater a short on the
  
  27   Wednesday, August 29, 2012, 14:52 John WongUCx#5LP-SISITWTM439165-5 FailedUCx#5 target description Wednesday, August 29, 2012, 14:50
UCx#5 target description, see attachment#1
The target is currently undergoing
 UCx#5_specifications.PNG 
  28   Wednesday, September 12, 2012, 01:53 John WongNb#7LP-SIS  39165-6 SpentNb#7 target description Wednesday, September 12, 2012, 02:10
Nb#7 target description: 
Total Nb foils = 400 discs
 Nb#7_target_description.jpg 
  31   Tuesday, March 19, 2013, 13:32 John WongSiC#28-RFQLP-SIS TM4LP-RFQ (NEW) SpentSiC#28-RFQ target description Tuesday, March 19, 2013, 12:28
SiC#28 - RFQ target description: 
Total SiC foils = 325 discs
 SiC#28_RFQ_density_measurements.xlsx 
  32   Thursday, April 11, 2013, 14:30 John WongTa#39LP-SISITWTM139165-7 SpentTa#39 target descriptionTa#38 LP-SIS target description:
Total Ta foils = 400
Foil Thickness = 0.025mm
  
  37   Friday, October 25, 2013, 17:35 John WongTa#41HP-SISITWTM438817-10 SpentTa#41 target descriptionFriday, October 25, 2013, 17:35
Ta#41 HP-SIS target description:
Total Ta foils = 400
  
  38   Wednesday, November 27, 2013, 17:56 John WongUCx#8LP-IG-LISITETM439814-IV SpentUCx#8 target description Wednesday, November 27, 2013, 17:49
UCx#8 target description - see attachment#1

 
 UCx_8_specification.PNG 
  41   Wednesday, April 30, 2014, 16:36 John WongSiC#30HP-FEBIADITETM338481-8 SpentSiC#30 Target description Wednesday, April 30, 2014, 15:16
Note:
This target was built in 2011. 
 SiC#30_density_measurements.xlsx 
  42   Friday, June 06, 2014, 14:09 John WongUCx#9LP-SIS  39165-9 ReadyUCx#9 - Target description  Friday, June 06, 2014, 14:08
See attachment for the target description

 
 UCx#9_target_description_1.JPG 
  43   Tuesday, July 15, 2014, 10:54 Laura LambertTa # 43LP-SISITWTM140282-2 ReadyTa # 43 Target Description Tuesday, July 15, 2014, 9:45
Ta#42 LP-SIS target description:
  
  44   Tuesday, July 15, 2014, 11:01 Laura LambertUCx # 10LP-SISITETM439165-10 ReadyUCx#10 Target DescriptionTuesday, July 15, 2014, 10:58
See attachment for target description 
 UCx_10_target_description.PNG 
  45   Monday, July 28, 2014, 15:57 John WongZrC#6LP-SISITWTM140282-3 SpentZrC target description  Monday, July 28, 2014, 15:52
See attachment#1 for ZrC target description. 
Target is currently undergoing the
 ZrC#6.JPG 
  46   Monday, August 18, 2014, 14:39 Laura LambertThO2 #1LP-SIS     ThO2 #1 Target DescriptionMonday, August 18, 2014, 14:53
See attachment for target description

 
 ThO2#1_target_description.JPG 
  48   Thursday, November 06, 2014, 13:35 Laura LambertUCx # 11LP-SISITETM440282-5 ReadyUCx#11 Target Description Thursday, November 06, 2014, 13:29
See attachment for target description

 
 UCx_11_target_description.PNG 
  49   Wednesday, April 01, 2015, 11:27 Laura LambertTa # 45HP-SIS  38817-5 In UseTa#45 target description Wednesday, April 01, 2015, 11:25
Ta#45 HP-SIS target description:
  
  50   Friday, April 17, 2015, 16:00 Laura LambertUCx # 12LP-SISITWTM141177-2 ReadyUCx#12 Target Description Thursday, April 16, 2015, 14:07
See attachment for target description
 UCx_12_target_description.PNG 
  51   Wednesday, April 29, 2015, 15:39 Laura LambertSiC#31HP-SIS  38817-7 ReadySiC#31 Target description Wednesday, April 29, 2015, 15:30
SiC#31 HP-SIS target description: 
 final_density_measurements.JPGdensity_measurements.xlsxSiC_density_Jan_10_'14_cast_-_Copy.xlsxSiC_density_Oct_31_'14_cast.xlsx 
  52   Wednesday, June 03, 2015, 10:55 Laura LambertZrC#7LP-SISITWTM241177-1 ReadyZrC#7 target description  Wednesday, June 03, 2015, 10:53
Total length packed = 12.3cm
See attachment for target description.
 target_production_elog_ZrC#7.JPGZrC#7_final_density.xlsx 
  53   Monday, July 06, 2015, 12:18 John WongZrC#7LP-SISITWTM241177-1 FailedZrC#7 target description

    

       
            
  
ELOG V2.9.2-2455