Entry  Wed Feb 22 21:51:40 2017, Keerthi Jayamanna, , , SIS first beam is N1+1 
Chris confirmed the first SIS beam would be Na+1. Next Rb+1 and then Li+1
Entry  Wed Feb 22 21:46:27 2017, Keerthi Jayamanna, , , Elog is working now 
Elog is now functioning. We can start entering notes
Entry  Mon Sep 14 11:21:16 2015, Keerthi Jayamanna, Routine, General, 20Ne+2 beam saved 
20Ne+2 beam optics saved as 150914_1117_ios0iosfc6.snap
Entry  Thu May 21 09:15:48 2015, Brian Minato, , ,  
Service of MCIS.  Plasma chamber cleaned.  Repaired shorted, Right steering plate.  Added shields to help prevent coating of wires. 
Beam is off centre on first collimator of steering assembly.
Moved Ground electrode away from PE approximately 0.10".
Entry  Wed Apr 29 07:48:22 2015, Brian Minato, Other, Other, Repair- Water leak inside HV cage 
A water leak was reported inside the HV cage (FR#8079).  The cage was accessed to determine the source of the leak (WP#I2015-04-27-1).
The WMS cusp cooling line was leaking.  It was close to the MCIS cart (at ground) and had sparked through.  The hose was cut at the puncture
location and re-connected. to the fitting.  It was re-routed to be further away from the MCIS cart.
Entry  Mon Apr 20 08:09:03 2015, Brian Minato, Routine, General, OLIS Shutdown Update 
The OLIS 1 week shutdown has been completed (WP 2015-04-13-1).
General-
Y-Box insulators were inspected and look good.  Beamline optics were inspected.
Entry  Wed Dec 17 13:17:13 2014, Brian Minato, Other, Other, MCIS Update 
The MCIS was vented with nitrogen yesterday.  The Se oven was drawn back into the tuner.  It was removed with the tuner and blanked.
The standard quartz window was removed and replaced with a ceramic, test window supplied by CPI. (p/n VWU2054).  The system is currently pumping
down.
Entry  Tue Nov 25 12:23:28 2014, Keerthi Jayamanna, Routine, General, 76Se+13 tune saved 
141125_1159_OLIS_76Se+13.snap is saved in reference directory.
El=3480/4303V
MCIS:YCB1=110
Entry  Tue Nov 25 07:49:50 2014, Brian Minato, Other, General, MCIS and SIS Update 
MCIS-
the Se was loaded into the oven last friday (21st).  During the weekend the presence of 76Se +11 to +15 was verified.
NOTE- the oven p/s on the cart is broken.  An attempt was made to remove it on friday.  It may be possible to remove, if the rack it
Entry  Wed Nov 19 11:34:55 2014, Raymond Dube, Routine, General, OLIS Electrical diagram with 3 I.S. ISK4586D-rev2.pdf
I updated the electrical Diagram  for OLIS Faraday Cage with 3 Ion Source, ref: ISK4586D rev. 2
PS:  Make sure that you do not connect both Bias P/S on same Ion Source ... 
Entry  Tue Nov 18 08:56:23 2014, Brian Minato, Other, General, ALGA Update 
There has been no noticeable loss of communication to the ALGA 50watt amplifier.  As a test, the ethernet cable was removed for about a minute and
then reconnected.  The amplifer re-established communication without issue.  This test was done twice.
Now, the CPI ethernet cable has been returned to the CPI amplifier.  The original ALGA ethernet cable (blue) has been reconnected to the ALGA.
Entry  Thu Nov 13 16:34:29 2014, Brian Minato, Other, Other, MCIS Update 
The ethernet cable from the CPI TWT amplifier has been temporarily moved to the Alga 50W amplifier.  The Alga had been experiencing loss of communication. 
This has not been an issue with the CPI so this cable will be tried with the Alga.  A signal generator is not connected to the Alga.
Entry  Thu Nov 13 16:31:54 2014, Brian Minato, Other, Other, SIS 
A new SIS source has been installed.  The oven has been loaded with Sodium Hydrogen Carbonate (Alfa Aesar 10863) and Rubidium Nitrate.
Pictures are located in 2014-11-13 Source and PS Pics
Entry  Wed Nov 12 13:32:47 2014, Raymond Dube, Routine, General, New in-line resistors for IOS:PE ISK4583D-rev10.pdf
Today we replace the in-line resistors for the Plasma Electrode (PE) it was a 25 ohm 200W (2 x 50 Ohm 100W) with a 50 Ohm 200W (2 x 100 Ohm / 100W) also
added the inductance coil.
This is R5 on drawing: ISK4583D rev. 10
Entry  Thu Nov 6 08:37:52 2014, Brian Minato, Other, Other, OLIS Update 
MCIS-
the source is off.  It is under vacuum and in the HV cage.
SIS-
Entry  Sat Nov 1 13:31:17 2014, Keerthi Jayamanna, , , MCIS readyness for 76Se 
Supernanogan is running with oven no heat, without 76selenium. MCIS:IG1=3e-7Torr.
Tune saved as 141101_1318_76Se+11tune.snap
MCIS steering  X=330, Y=226, CCB1=500, MCISEL=4171/5157, PE=11.5/23, FC6=76nA(16O+7)
Entry  Fri Oct 31 20:39:56 2014, Brian Minato, Other, Other, OLIS Update 
MCIS-
the MWS Bias and PE have been moved on to the MCIS (the MCIS connections have been removed).
The plug in power to the HP Signal generator has been moved to a continuous source (Removed from the source controlled by the SSW).
Entry  Thu Oct 30 23:44:57 2014, Keerthi Jayamanna, Routine, General, OLIS Supernanogan mass scan 6 to 7.5 
A/q           FC6  (only current over 100pA)
6.0           1.85e-7
6.15         4.96e-10
Entry  Thu Oct 30 23:37:58 2014, Keerthi Jayamanna, Routine, General, Mass scan 4 to 6 
A/Q            FC6
4                1.1e-6
4.25          8e-10
Entry  Thu Oct 30 22:44:45 2014, Keerthi Jayamanna, Routine, General, Mass scan 3 to 4 
IOS mass scan if faulty. These is a manual scan from mass 3 to 4
Const22 = 0.04187  adjusted to mass = 4
A/q               FC6           X         