ID |
Date |
Author |
Category |
Type |
Module |
Target/Number |
Subject |
288
|
Thursday, April 04, 2013, 12:07 |
Bevan Moss | Conditioning Station | Standard Operation | TM1 | Ta #39 | Roughing started | Roughing started at 12:06. It was believed there was a problem with the compressed air but there was none, TM1 doesn't leak and so you cannot hear that the connection is made. |
289
|
Thursday, April 04, 2013, 14:31 |
Bevan Moss | Conditioning Station | Standard Operation | TM1 | Ta #39 | Roughing started |
Bevan Moss wrote: |
Roughing started at 12:06. It was believed there was a problem with the compressed air but there was none, TM1 doesn't leak and so you cannot hear that the connection is made.
|
Roughing stopped as the module and cover requires modifications that require the vacuum to be opened. |
290
|
Monday, April 08, 2013, 09:01 |
Travis Cave | Conditioning Station | Standard Operation | TM1 | Ta#39 | Electrical check | TM#1 with Ta#39 at the conditioning station, has failed its electrical test see attached pdf for details. Also while setting up for the electrical test one of the high powered flexible connectors popped out its crimp and another is working it out its crimp. |
Attachment 1: TM1_Ta39_CS_ELEC_CHK.PDF
|
|
291
|
Monday, April 08, 2013, 12:10 |
Travis Cave | Conditioning Station | Standard Operation | TM1 | Ta#39 | Electrical check | TM#1 with Ta#39 had the electrical check done on it again it passed, changes this time were the water lines were purged and it was under a better then roughing vacuum. See the attached pdf for details. |
Attachment 1: TM1_Ta39_CS_ELEC_CHK2.PDF
|
|
292
|
Monday, April 08, 2013, 16:16 |
Bevan Moss | Conditioning Station | Standard Operation | TM1 | Ta #39 | Venting with Argon | TM1 started venting at 4:15 pm with Argon. I will leave the valve open over night. |
293
|
Tuesday, April 09, 2013, 09:06 |
Travis Cave | Conditioning Station | Standard Operation | TM1 | Ta#39 | Electrical check | TM#1 with Ta#39 has not passed it electrical check again, while sitting at the conditioning station at air. The readings have not been consistant. See the current PDF for details.
TM#1 with Ta#39 electrical check at the target station see attached PDF (CHK 4).(April 9th 2013) PASSED
TM#1 with Ta#39 electrical check at the target station see attached PDF (CHK 5).(April 10th 2013) PASSED |
Attachment 1: TM1_Ta39_CS_ELEC_CHK3.PDF
|
|
Attachment 2: TM1_Ta39_CS_ELEC_CHK4.PDF
|
|
Attachment 3: TM1_Ta39_CS_ELEC_CHK5.PDF
|
|
294
|
Thursday, April 11, 2013, 07:18 |
David Wang | Conditioning Station | Maintenance | TM1 | Ta#29 | helium pressure tested all water lines in TM1 at CS | On April 08th, all water lines in TM1 had been helium pressure tested(70psi) at conditioning station. No leak had been found. |
303
|
Wednesday, April 17, 2013, 10:59 |
Travis Cave | Conditioning Station | Standard Operation | TM3 | no target | module move | TM#3 with no target has been moved from the south hot cell to the conditioning station. Move went well. The fields around the module was 1.6mSv/hr. |
304
|
Wednesday, April 17, 2013, 15:17 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | N/A | Turbo Pumps Failed | Both Turbo pumps on TM3 have failed. They were both attempted to start in soft mode. TP2 could only achieve ~19kpm and TP1 ~10kpm. I have turned off the scroll pump and vented through the turbo pumps. |
305
|
Friday, April 19, 2013, 10:48 |
Bevan Moss | Conditioning Station | Maintenance | TM3 | N/A | Turbo Pump 2 replaced | Turbo Pump 2 has been replaced on TM3. I got a count of 350 on the sleeve of my tank suit. |
306
|
Friday, April 19, 2013, 10:48 |
Bevan Moss | Conditioning Station | Maintenance | TM3 | N/A | Turbo Pump 2 replaced | Turbo Pump 2 has been replaced on TM3. I got a count of 350 on the sleeve of my tank suit. |
307
|
Friday, April 19, 2013, 10:51 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | N/A | Roughing Started 10:48 | With the Turbo pump replaced I have started roughing at 10:48 |
308
|
Friday, April 19, 2013, 13:32 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | N/A | Turbo Pumps Started | Both Turbo Pumps are now operational. |
309
|
Friday, April 19, 2013, 15:25 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | N/A | Turbo Pumps Started |
Bevan Moss wrote: |
Both Turbo Pumps are now operational.
|
Turbo pumps 1 and 2 both found randomly off, have been restarted |
310
|
Monday, April 22, 2013, 09:33 |
David Wang | Conditioning Station | Repair | TM3 | | Leak check TM3 at conditioning station | TM3 leak check at conditioning station without target: TM3 all air to vacuum seals have been leak checked . They are all good. Water lines TAR(+-), TUBE(+-), GAS, MSP , COIL2(+-), EE, HS(1,2) , GE,and WINDOW have been helium pressurized to 70 psi for 2 minutes each . No response had been found on leak detector. They are leak tight.. Leak detector BR 0.0xE-9atm.cc/sec, BP 0.0xE-4 torr. TM3 and CS vacuum: PNG15.2xE-6 torr, IG1 8.8xE-7 torr,IG2 2.8xE-6torr, IG1S 1.3xE-6 torr. |
311
|
Monday, April 22, 2013, 11:31 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | N/A | Cooling Package Started | Cooling Package was started at 9:25 this morning inlet conductivity is 0.08 Mohm at 22.9C. Resistance reached 5.33 Mohm by 11:30 |
312
|
Monday, April 22, 2013, 11:35 |
Bevan Moss | Conditioning Station | Repair | TM3 | N/A | TCS:DIF2 broken | The flow meter on the primary side (TCS:DIF2) of the conditioning station is broken. I investigated and there is flow, the gauge is not fouled, and the PLC does read back when current supplied. The gauge is also reciving 24V but the output is 0V and 0mA. I will contact ESC and the supplier. |
313
|
Tuesday, April 23, 2013, 11:19 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | N/A | HV Test All common | A HV test was conducted yesterday on TM3. There was no target and all items were tied to common or ground. The conductivity of the water ranged from 7.1 to 7.5 Mohm. 40kV @ ~600uA without continuous sparking was achieved. The Strip tool was run but something went wrong with the export and the vacuum gauge data is missing. I have attached the file for reference and the pulled data from the achiver (only logs every 300 seconds). RGA scans were taken periodically during the test nothing unexpected was measured but we also do not know what normal looks like. The RGA application is available at http://www.thinksrs.com/downloads/soft.htm. Other items of note include significant sparks disrupts the communication between the computer and the RGA, the PNG1 gauge and its controller, and TP2 local readout screen. |
Attachment 1: TM3_40kV_22042013.txt
|
Time TCS:DIC1:RDCOND [Mohm] TCS:BIAS:RDVOL [V] TCS:BIAS:RDCUR [uA] TCS:IG1:RDVAC [T] TCS:PNG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:EL:RDVOL [V] TCS:EL:RDCUR [mA]
04/22/2013 13:24:54.514767 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:24:55.514144 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:24:56.513959 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:24:57.513859 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:24:58.513733 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:24:59.513611 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:00.513548 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:01.513332 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:02.513198 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:03.513101 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:04.512953 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:05.512845 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:06.512694 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:07.512593 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:08.512476 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:09.512319 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:10.513224 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:11.513065 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:17.483675 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:18.483198 7.3 12.58 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:19.483074 7.3 12.58 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:20.482940 7.3 12.58 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:21.482848 7.3 12.58 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:22.529120 7.3 11.44 3.05 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:23.528590 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:24.528438 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:25.528305 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:26.528488 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:27.529055 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:28.528932 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:29.528851 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:30.528683 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:31.528587 7.3 13.73 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:32.533445 7.3 13.73 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:33.533327 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:34.537373 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:35.537097 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:36.537751 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:37.537820 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:38.538733 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:39.538569 7.3 12.58 3.05 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:40.538418 7.3 12.58 3.05 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:41.538297 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:42.538165 7.3 11.44 3.35 0.00 BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:43.538047 7.3 11.44 3.05 0.00 BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:44.537916 7.3 11.44 3.05 0.00 BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:45.538903 7.3 13.73 3.05 0.00 BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:46.539694 7.3 13.73 3.05 0.00 BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:47.539540 7.3 13.73 3.05 0.00 0.00 BadVal BadVal BadVal BadVal
04/22/2013 13:25:48.539419 7.3 13.73 3.05 0.00 0.00 BadVal BadVal BadVal BadVal
04/22/2013 13:25:49.539292 7.3 11.44 3.35 0.00 0.00 BadVal BadVal BadVal BadVal
04/22/2013 13:25:50.539189 7.3 11.44 3.35 0.00 0.00 BadVal BadVal BadVal BadVal
04/22/2013 13:25:51.540060 7.3 11.44 3.35 0.00 0.00 BadVal BadVal BadVal BadVal
04/22/2013 13:25:52.539908 7.3 11.44 3.35 0.00 0.00 0.00 BadVal BadVal BadVal
04/22/2013 13:25:53.540092 7.3 13.73 3.35 0.00 0.00 0.00 BadVal BadVal BadVal
04/22/2013 13:25:54.539666 7.3 13.73 3.35 0.00 0.00 0.00 BadVal BadVal BadVal
04/22/2013 13:25:55.539575 7.3 11.44 3.35 0.00 0.00 0.00 BadVal BadVal BadVal
04/22/2013 13:25:56.539413 7.3 11.44 3.35 0.00 0.00 0.00 BadVal BadVal BadVal
04/22/2013 13:25:57.539286 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:25:58.539153 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:25:59.538179 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:00.538903 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:01.538871 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:02.538659 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:03.538562 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:04.538446 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:05.538316 7.3 12.58 3.05 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:06.538222 7.3 12.58 3.05 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:07.538075 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:08.538171 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:09.537838 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:10.537655 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:11.537527 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:12.537436 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:13.537268 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:14.537406 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:15.639967 7.3 11.44 3.05 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:16.639887 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:17.640787 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:18.640626 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:19.640619 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:20.640442 7.3 10.29 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:21.640369 7.3 10.29 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:22.641183 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:23.641029 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:24.640866 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:25.640747 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:26.640673 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:28.178982 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:29.179353 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 BadVal
04/22/2013 13:26:30.179183 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 BadVal
04/22/2013 13:26:31.179057 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 BadVal
04/22/2013 13:26:32.178947 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 BadVal
04/22/2013 13:26:33.178849 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 BadVal
04/22/2013 13:26:34.178693 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:35.178556 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:36.178472 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:37.178303 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:38.178200 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:39.178042 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:40.177926 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:41.177844 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:42.177729 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:43.177629 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:44.178423 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:45.178297 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:46.178170 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:47.178089 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:48.177940 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:49.177787 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:50.177668 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:51.177687 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:52.177542 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:53.177297 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:54.177157 7.3 10.29 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:55.177042 7.3 10.29 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:56.176917 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:57.178097 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:58.177734 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:59.177581 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:00.177404 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:01.177286 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:02.177183 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:03.176688 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:04.666538 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:05.666722 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:06.666638 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:07.666465 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:08.666344 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:09.667231 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:10.667092 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:11.666959 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:12.667834 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:13.667734 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:15.455589 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:16.456394 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:17.456238 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:18.456114 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:19.455993 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:20.456902 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:21.457770 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:22.457610 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:23.457575 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:24.458447 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:25.674933 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:26.675079 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:27.675945 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:28.676017 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:29.838968 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:30.839556 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:31.840473 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:32.840332 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:33.840185 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:35.391801 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:36.391894 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:37.391731 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:38.391621 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:39.391692 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:40.391384 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:41.392220 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:42.392106 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:43.391978 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:44.391852 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:45.391725 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:46.392637 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:47.392514 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:48.393342 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:49.393223 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:50.393089 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:51.392628 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:52.391846 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:53.391713 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:54.391594 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:55.391630 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:56.675906 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:57.676197 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:58.676065 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:59.677227 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:00.676804 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:01.677695 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:02.677596 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:03.678503 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:04.678447 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:06.399267 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:07.400070 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:08.399885 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:09.399809 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:10.399619 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:11.399516 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:13.656395 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:14.657070 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:15.657936 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:16.657789 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:17.657670 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:18.657620 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:19.657463 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:20.657285 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:21.658248 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:22.658068 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:23.657983 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:24.657790 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:25.657704 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:26.657530 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:27.657455 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:28.658316 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:29.658187 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:31.671569 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:32.671781 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:33.672687 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:34.672520 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:35.672422 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:36.672317 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:37.672165 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:38.673107 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:39.672891 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:40.673766 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:41.673690 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:42.673544 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:43.674557 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:44.675383 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:45.675156 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:46.676069 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:47.675919 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:49.380871 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:50.380556 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:51.380432 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:52.380347 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:53.380179 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:54.380078 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:55.380951 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:56.380800 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:57.380707 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:58.380548 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:59.380422 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:00.380338 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:01.380171 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:02.381040 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:03.380921 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:04.380793 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:05.380668 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:06.380651 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:07.380416 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:08.381334 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:09.381207 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:10.382058 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:11.381912 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:12.381849 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:13.382656 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:14.382594 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:15.382427 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:16.382327 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:17.649989 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:18.650082 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:19.650924 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:20.650767 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:21.650681 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:22.650530 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:23.650713 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:24.651319 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:25.651199 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:26.650994 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:27.650869 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:28.650773 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:29.651613 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:30.651518 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:31.651394 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:32.651287 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:33.651133 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:34.651100 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:35.650874 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:36.650730 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:37.650604 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:38.650563 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:39.651352 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:40.651309 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:41.651192 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:42.651973 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:43.651850 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:44.651761 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:45.651628 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:46.719742 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:47.719345 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:48.719221 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:49.720162 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:50.719968 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:51.719843 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:52.719718 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:53.719634 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:54.720478 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:55.720383 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:56.720276 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:57.721104 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:58.720977 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:59.721860 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:30:00.721721 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:30:01.721675 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:30:02.722507 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:30:03.723371 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:30:04.724289 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
... 7200 more lines ...
|
Attachment 2: 22042013_TM3_40kV_Archiver.csv
|
, , TCS:PNG1:RDVAC, TCS:BIAS:RDCUR, TCS:BIAS:RDVOL, TCS:IG1:RDVAC, TCS:IG2:RDVAC, TCS:IG1S:RDVAC,,
0,04/22/13 13:01:28,7.23077e-06,12.5124,49.2103,9.26374e-07,4.7033e-06,2.04395e-06
1,04/22/13 13:06:28,7.01099e-06,12.5124,46.9215,9.28571e-07,4.7033e-06,2e-06
2,04/22/13 13:11:29,7.05494e-06,12.5124,46.9215,9.28571e-07,4.7033e-06,2.04395e-06
3,04/22/13 13:16:29,7.12088e-06,12.5124,45.7771,9.28571e-07,4.68132e-06,2e-06
4,04/22/13 13:21:30,7.14286e-06,3.0518,10.2998,9.28571e-07,4.7033e-06,2e-06
5,04/22/13 13:26:30,7.12088e-06,3.35698,11.4443,9.28571e-07,4.7033e-06,2.02198e-06
6,04/22/13 13:31:31,7.07692e-06,3.35698,11.4443,9.26374e-07,4.81319e-06,2.02198e-06
7,04/22/13 13:36:31,7.07692e-06,3.35698,11.4443,9.30769e-07,4.83516e-06,2e-06
8,04/22/13 13:41:32,7.16484e-06,13.7331,1005.95,9.28571e-07,4.81319e-06,2.02198e-06
9,04/22/13 13:46:33,7.12088e-06,54.3221,4007.78,9.28571e-07,4.79121e-06,2.04395e-06
10,04/22/13 13:51:33,7.12088e-06,101.93,7512.02,9.30769e-07,4.79121e-06,2e-06
11,04/22/13 13:56:34,7.20879e-06,150.149,11015.1,9.28571e-07,4.81319e-06,2.04395e-06
12,04/22/13 14:01:34,7.0989e-06,198.978,14517.1,9.30769e-07,4.81319e-06,1.97802e-06
13,04/22/13 14:06:35,7.0989e-06,241.093,17520,9.30769e-07,4.83516e-06,2e-06
14,04/22/13 14:11:35,7.14286e-06,290.837,21023.1,9.35165e-07,4.83516e-06,2e-06
15,04/22/13 14:16:36,7.18681e-06,349.737,25025.2,9.30769e-07,4.83516e-06,1.97802e-06
16,04/22/13 14:21:36,7.82417e-06,357.366,25526.4,9.35165e-07,4.85714e-06,2.02198e-06
17,04/22/13 14:26:37,7.67033e-06,381.781,27026.8,9.35165e-07,4.85714e-06,2e-06
18,04/22/13 14:31:37,7.2967e-06,405.89,28027,9.37362e-07,4.85714e-06,2e-06
19,04/22/13 14:36:38,7.25275e-06,419.623,29528.5,9.35165e-07,4.9011e-06,2.02198e-06
20,04/22/13 14:41:39,7.14286e-06,434.577,30028.6,9.39561e-07,4.85714e-06,2.02198e-06
21,04/22/13 14:46:39,7.23077e-06,451.667,31529,9.41758e-07,4.85714e-06,1.97802e-06
22,04/22/13 14:51:40,7.20879e-06,475.166,33029.3,9.39561e-07,4.87912e-06,2e-06
23,04/22/13 14:56:40,7.27473e-06,509.957,35030.9,9.43956e-07,4.87912e-06,2.02198e-06
24,04/22/13 15:01:41,7.16484e-06,534.676,36531.2,9.43956e-07,4.87912e-06,2e-06
25,04/22/13 15:06:41,8.13187e-06,572.519,38532.8,1.36264e-06,5.69231e-06,2.43956e-06
26,04/22/13 15:11:42,7.27473e-06,585.336,39533.1,9.46154e-07,4.9011e-06,2.04395e-06
27,04/22/13 15:16:42,7.25275e-06,596.017,40033.2,9.5055e-07,4.96703e-06,2e-06
28,04/22/13 15:21:43,7.47253e-06,607.919,40533.3,9.61538e-07,5.0989e-06,2.13187e-06
29,04/22/13 15:26:43,7.23077e-06,0,78.9654,9.46154e-07,4.85714e-06,2.02198e-06
30,04/22/13 15:31:44,7.16484e-06,0,10.2998,9.37362e-07,4.81319e-06,2e-06
31,04/22/13 15:36:45,7.0989e-06,12.2072,48.0659,9.32967e-07,4.79121e-06,1.97802e-06
32,04/22/13 15:41:45,7.03297e-06,12.2072,45.7771,9.28571e-07,4.74725e-06,1.97802e-06
33,04/22/13 15:46:46,6.98901e-06,14.6487,50.3548,9.28571e-07,4.72528e-06,2e-06
34,04/22/13 15:51:46,6.96703e-06,14.6487,52.6436,9.26374e-07,4.7033e-06,1.93407e-06
35,04/22/13 15:56:47,6.96703e-06,14.6487,50.3548,9.21978e-07,4.7033e-06,1.95604e-06
36,04/22/13 16:01:47,6.9011e-06,14.6487,52.6436,9.1978e-07,4.65934e-06,1.95604e-06
37,04/22/13 16:06:48,6.94505e-06,14.6487,49.2103,9.1978e-07,4.65934e-06,1.93407e-06
38,04/22/13 16:11:48,6.9011e-06,14.6487,49.2103,9.21978e-07,4.63736e-06,1.93407e-06
39,04/22/13 16:16:49,6.94505e-06,14.6487,52.6436,9.21978e-07,4.63736e-06,1.93407e-06
40,04/22/13 16:21:49,6.9011e-06,14.6487,50.3548,9.21978e-07,4.65934e-06,1.91209e-06
41,04/22/13 16:26:50,7.05494e-06,14.6487,52.6436,9.17582e-07,4.65934e-06,1.93407e-06
|
Attachment 3: RGA_files.zip
|
314
|
Tuesday, April 23, 2013, 13:48 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | N/A | EL testing | This morning the Einzel Lens was tested on TM3 as the intention is to reuse this piece of equipment. The EL was able to achieve 39.9kV at ~1.35mA before a major spark happened and the power supply turned off. Also during testing the penning gauge suddenly shot up after a spark, it did not recover and had been acting strange in previous test, it was decided to ignore its value and continue testing but it should be replaced in the future. When I went to save the strip tool data I tried to save it as SDDS binary data out of curiosity and the tool crashed, it turns out this is on old feature and doesn't work anymore. A file was created but I cannot recover any of the data. If I do manage to do so I will will attach it later. Attached is the RGA and Archiver data.
Other items of note:
Voltage was increased in 1000V increments until ~32kV when it started to have sparks. Increases were then reduced to 500V until 38kV when it sparked and further reduced to 100V increments where it worked until 39.9kV
There is a inline and ballast resistor on the EL circuit values of each respectively are 145Kohm and 200 Mohm
The rga application is available at
http://www.thinksrs.com/downloads/soft.htm
|
Attachment 1: 23042013_TM3_EL_RGA.zip
|
Attachment 2: 23042013_TM3_EL_39.csv
|
, , TCS:EL:RDVOL, TCS:EL:RDCUR, TCS:PNG1:RDVAC, TCS:IG1:RDVAC, TCS:IG2:RDVAC, TCS:IG1S:RDVAC,,
0,04/23/13 11:03:53,31.1284,0.0526436,7.40659e-06,9.59341e-07,4.81319e-06,1.58242e-06
1,04/23/13 11:08:53,31.1284,0.0526436,7.42857e-06,9.61538e-07,4.79121e-06,1.58242e-06
2,04/23/13 11:13:54,31.1284,0.0526436,7.40659e-06,9.61538e-07,4.76923e-06,1.58242e-06
3,04/23/13 11:18:54,31.1284,0.0526436,7.40659e-06,9.59341e-07,4.81319e-06,1.58242e-06
4,04/23/13 11:23:55,5.49325,0.0526436,7.42857e-06,9.61538e-07,4.79121e-06,1.56044e-06
5,04/23/13 11:28:55,5.49325,0.0526436,7.45055e-06,9.57143e-07,4.9011e-06,1.51648e-06
6,04/23/13 11:33:56,999.771,0.0434882,7.4945e-06,9.52747e-07,4.74725e-06,1.53846e-06
7,04/23/13 11:38:57,15010,0.510414,7.23077e-06,9.39561e-07,4.7033e-06,1.51648e-06
8,04/23/13 11:43:57,25012,0.859846,7.0989e-06,9.28571e-07,4.5934e-06,1.51648e-06
9,04/23/13 11:48:58,31012.4,1.09102,0.000182418,9.1978e-07,4.50549e-06,1.4945e-06
10,04/23/13 11:53:58,31012.4,1.09102,0.000138462,9.15385e-07,4.48352e-06,1.47253e-06
11,04/23/13 11:58:59,36010.1,1.17266,0.000125275,9.10989e-07,4.46154e-06,1.47253e-06
12,04/23/13 12:03:59,39408.6,1.36339,0.00010989,9.06594e-07,4.41758e-06,1.40659e-06
13,04/23/13 12:09:00,6.10361,0.0289921,0.000107692,9.04396e-07,4.41758e-06,1.45055e-06
14,04/23/13 12:14:00,5.49325,0.0289921,0.000105494,9.02198e-07,4.37363e-06,1.40659e-06
15,04/23/13 12:19:01,5.49325,0.0289921,0.000105494,9.02198e-07,4.35165e-06,1.40659e-06
16,04/23/13 12:24:01,5.49325,0.0289921,0.000103297,8.97802e-07,4.35165e-06,1.40659e-06
17,04/23/13 12:29:02,5.49325,0.0289921,0.000101099,8.97802e-07,4.32967e-06,1.40659e-06
18,04/23/13 12:34:03,5.49325,0.0289921,0.000103297,8.97802e-07,4.30769e-06,1.36264e-06
19,04/23/13 12:39:03,5.49325,0.0289921,0.000103297,8.93406e-07,4.30769e-06,1.36264e-06
20,04/23/13 12:44:04,5.49325,0.0289921,0.000103297,8.95605e-07,4.28571e-06,1.36264e-06
21,04/23/13 12:49:04,5.49325,0.0289921,0.000107692,8.95605e-07,4.30769e-06,1.38462e-06
22,04/23/13 12:54:05,5.49325,0.0289921,0.000101099,8.93406e-07,4.30769e-06,1.36264e-06
23,04/23/13 12:59:05,5.49325,0.0289921,0.000103297,8.93406e-07,4.28571e-06,1.36264e-06
|
315
|
Tuesday, April 23, 2013, 15:52 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | N/A | Further HV Testing | Further HV testing was completed today from ~2:00 until 3:00. The resistivity of the water was 11.7 - 12.7 Mohm. The EE was turned on to 1500 V and had a leakage current of 1.465 mA with a inline and ballast resister of 20 kohm and 1 Mohm respectively. In addition to this all of the CB were turned on to 500V. The voltage on the source tray with all bias items tied together and the voltage was then raised to 30kV in 5kV steps. It was then raised until 37kV in 1kV step at which point the first spark was detected. Steps were then reduced to 500V until 39.5kV was achieved. Sparking was noticed when stepping up from one voltage to the next and steps were reduced to 100V. At 39.7 kV there were several sparks and the voltage was held for 8 minutes until there had been at least 4 minutes since the last spark. Voltage was increased to 41.2 kV at 292.97 uA when a spark caused the HVCLTBHT paddle wheel flow sensor to trip. Flow was affected but the interlock was tripped due to noise and as a result the BIAS and EE voltage dropped to zero. At this point the required data had been collected and it was decided to shut the station down. RGA scans were taken during the test and are attached. The edited data with graphs is attached in the excel folder. PNG1 was not monitored as it has failed.
The rga application is available at
http://www.thinksrs.com/downloads/soft.htm
|
Attachment 1: TM3_BIAS_EE_CB_23042013.xlsx
|
Attachment 2: TM3_BIA_EE_CD_23042013_RGA_files.zip
|
|