Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC, Page 9 of 141  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Author Category Type Moduledown Target/Number Subject
  515   Monday, October 21, 2013, 12:29 Bevan MossConditioning StationRepairTM4 BIAS Canbus

 There is something wrong with the BIAS canbus controller. It says that it is not alive and has timed out. I have tried unplugging it and plugging it back in but that has not resolved the problem as it normally does. I have contacted Dave Morris and am waiting to hear from him. I cannot HV test without this controller.

  519   Tuesday, October 22, 2013, 17:04 Bevan MossConditioning StationStandard OperationTM4 HV testing

 This afternoon TM4 with the coil removed was tested with HV. The EINZEL LENS was first tested independently while the bias canbus was being repaired. The current on the EL looked stable at 25kV for 5 minutes. At 27.5kV the current becomes unstable and occasionally sparks. This voltage was held for 30 minutes but the current did not appear to be becoming more stable. Further extended testing would be required to determine if this can be conditioned out. At this point I would suggest the EL has a HV limit near 25kV.

The BIAS and EL were then brought up to 35kV and 17.5kV respectively. This voltage was held for 35 minutes with the BAIS only sparking twice. The module can most likely hold a higher voltage but for the next 2 runs does not require more than 35kV. Further testing was not completed due to time constraints. It is recommended during the shut down that TM4 is tested to its limits. The data from the testing has been attached.

Attachment 1: 22102013_TM4_Coil_removed_EL_testing_(1).txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	
10/22/2013 13:37:21.862267	                      0.000000770                      0.000004395                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:22.872355	                      0.000000770                      0.000004395                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:23.873054	                      0.000000770                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:24.872963	                      0.000000772                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:25.873079	                      0.000000772                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:26.873705	                      0.000000768                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:27.876578	                      0.000000770                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:29.375243	                      0.000000772                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:30.375246	                      0.000000772                      0.000004439                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:31.375149	                      0.000000768                      0.000004439                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:32.375021	                      0.000000768                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:33.374899	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:34.374768	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:35.375612	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:36.375526	                      0.000000768                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:37.375398	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:38.375234	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:39.375138	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:40.375023	                      0.000000772                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:41.374896	                      0.000000768                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:42.382861	                      0.000000772                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:43.389486	                      0.000000768                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:44.389518	                      0.000000770                      0.000004417                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:45.389366	                      0.000000770                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:46.389277	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:47.389116	                      0.000000770                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:48.389022	                      0.000000765                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:49.388887	                      0.000000768                      0.000004351                      0.000003010                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:50.388761	                      0.000000772                      0.000004395                      0.000003076                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:51.389631	                      0.000000770                      0.000004373                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:52.389519	                      0.000000768                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:53.389503	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:54.390277	                      0.000000770                      0.000004373                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:55.390109	                      0.000000770                      0.000004373                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:56.433276	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:57.518991	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:58.518716	                      0.000000770                      0.000004439                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:59.518620	                      0.000000768                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:00.518493	                      0.000000772                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:01.518366	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:02.518218	                      0.000000770                      0.000004417                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:03.518084	                      0.000000770                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:04.517962	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:05.517837	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:06.517742	                      0.000000772                      0.000004373                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:07.517620	                      0.000000768                      0.000004417                      0.000003010                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:08.517462	                      0.000000768                      0.000004417                      0.000003010                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:09.517388	                      0.000000768                      0.000004373                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:10.517236	                      0.000000770                      0.000004351                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:11.518181	                      0.000000770                      0.000004373                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:12.518953	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:13.518826	                      0.000000770                      0.000004395                      0.000003010                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:14.518758	                      0.000000772                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:15.518636	                      0.000000768                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:16.519487	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:17.519350	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:18.519257	                      0.000000774                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:19.519328	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:20.731644	                      0.000000772                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:21.731831	                      0.000000768                      0.000004417                      0.000003054                             6.10                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:22.731710	                      0.000000770                      0.000004395                      0.000003054                             6.10                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:23.731555	                      0.000000770                      0.000004395                      0.000003032                             6.10                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:25.760555	                      0.000000770                      0.000004395                      0.000003054                             6.10                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:26.760175	                      0.000000770                      0.000004395                      0.000003054                             6.10                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:27.760065	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:28.759915	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:29.759835	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:30.759664	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:31.759538	                      0.000000772                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:32.759422	                      0.000000772                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:33.759333	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:34.759215	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:35.759046	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:36.758910	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:38.267460	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:39.281825	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:40.838079	                      0.000000768                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:41.838491	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:42.839175	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:43.839077	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:44.838990	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:45.838859	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:46.839758	                      0.000000772                      0.000004373                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:47.839578	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:48.839436	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:49.839324	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:50.839153	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:51.839046	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:52.838957	                      0.000000772                      0.000004439                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:53.838832	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:54.838643	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:55.838561	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:56.838643	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:57.838361	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:58.838149	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:59.838017	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:00.837928	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:01.837766	                      0.000000768                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:02.837672	                      0.000000770                      0.000004373                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:03.837571	                      0.000000768                      0.000004373                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:04.837427	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:05.837619	                      0.000000772                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:06.838137	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:07.838061	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:08.837915	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:09.837804	                      0.000000765                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:10.837679	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:11.837545	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:12.837420	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:13.837268	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:14.837161	                      0.000000768                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:15.837034	                      0.000000772                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:16.837067	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:17.837757	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:18.838661	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:19.838546	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:20.838389	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:21.838289	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:22.838190	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:23.838035	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:24.837899	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:25.837761	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:26.837703	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:27.837513	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:28.837387	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:29.837306	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:30.837310	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:31.837158	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:32.837997	                      0.000000768                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:33.837790	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:34.837626	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:35.837509	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:36.837458	                      0.000000768                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:37.837295	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:38.837234	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:39.837040	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:40.836909	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:41.836799	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:42.836627	                      0.000000770                      0.000004395                      0.000002989                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:43.836540	                      0.000000772                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:44.836412	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:45.836245	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:46.836124	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:47.836171	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:48.835873	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:49.835754	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:50.835627	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:51.835524	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:52.835433	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:53.834560	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:54.835013	                      0.000000770                      0.000004395                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:55.834998	                      0.000000770                      0.000004395                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:56.834926	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:57.834780	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:58.834622	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:59.835523	                      0.000000768                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:00.835395	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:01.835237	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:02.835147	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:03.835023	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:04.834922	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:05.834744	                      0.000000770                      0.000004439                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:06.834646	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:07.834561	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:08.835478	                      0.000000768                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:09.835267	                      0.000000768                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:10.836453	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:11.837024	                      0.000000768                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:12.836999	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:13.836775	                      0.000000772                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:14.836652	                      0.000000770                      0.000004439                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:15.836519	                      0.000000770                      0.000004439                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:16.837395	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:17.837231	                      0.000000772                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:18.837144	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:19.837023	                      0.000000768                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:20.836945	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:21.837760	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:22.837632	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:23.837573	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:24.837392	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:25.837574	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:26.838169	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:27.839066	                      0.000000768                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:28.839851	                      0.000000768                      0.000004417                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:29.840785	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:30.840634	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:31.840502	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:32.840355	                      0.000000770                      0.000004373                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:33.840251	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:34.840142	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:35.839979	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:36.839879	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:37.839787	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:38.839595	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:39.839510	                      0.000000772                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:40.839534	                      0.000000770                      0.000004417                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:41.839247	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:42.839095	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:43.838993	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:44.838897	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:45.838839	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:46.839621	                      0.000000770                      0.000004417                      0.000003054                          5001.90                             0.18                           BadVal                           BadVal
10/22/2013 13:40:47.839509	                      0.000000765                      0.000004395                      0.000003032                          5001.90                             0.18                           BadVal                           BadVal
10/22/2013 13:40:48.839389	                      0.000000770                      0.000004351                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:49.839279	                      0.000000768                      0.000004373                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:50.839135	                      0.000000770                      0.000004395                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:51.838968	                      0.000000770                      0.000004395                      0.000003054                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:52.838902	                      0.000000772                      0.000004395                      0.000003054                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:53.838753	                      0.000000772                      0.000004373                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:54.838630	                      0.000000770                      0.000004395                      0.000003054                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:55.838506	                      0.000000772                      0.000004373                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:56.838391	                      0.000000770                      0.000004373                      0.000003054                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:57.839213	                      0.000000770                      0.000004417                      0.000003054                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:58.839095	                      0.000000770                      0.000004439                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:59.839001	                      0.000000770                      0.000004417                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:41:00.838842	                      0.000000770                      0.000004417                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:41:01.838827	                      0.000000770                      0.000004395                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:41:02.838593	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:03.838568	                      0.000000770                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:04.838342	                      0.000000770                      0.000004373                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:05.838244	                      0.000000772                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:06.876299	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:07.877007	                      0.000000765                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:08.876853	                      0.000000765                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:09.876746	                      0.000000768                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:10.876648	                      0.000000772                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:11.876521	                      0.000000770                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:12.876343	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:13.943583	                      0.000000772                      0.000004439                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:14.944216	                      0.000000774                      0.000004439                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:15.945081	                      0.000000768                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:16.944824	                      0.000000768                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:17.944730	                      0.000000770                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:18.944595	                      0.000000768                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:19.945612	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:20.945476	                      0.000000770                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:21.946189	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:22.946485	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:23.946234	                      0.000000770                      0.000004373                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:24.947072	                      0.000000768                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:25.947686	                      0.000000768                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:26.947607	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:27.948498	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:28.948474	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:29.948193	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:30.948120	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:31.947932	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:32.947848	                      0.000000770                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:33.947692	                      0.000000770                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:34.947592	                      0.000000770                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:35.948464	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:36.948315	                      0.000000770                      0.000004395                      0.000003010                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:37.948274	                      0.000000768                      0.000004395                      0.000003010                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:38.948093	                      0.000000768                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:39.948061	                      0.000000770                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:40.948932	                      0.000000772                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:41.948893	                      0.000000770                      0.000004373                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:42.949555	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:43.949438	                      0.000000770                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:44.949388	                      0.000000768                      0.000004373                      0.000003010                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:45.950241	                      0.000000770                      0.000004395                      0.000003010                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:46.950081	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:47.950060	                      0.000000768                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:48.949881	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:49.949720	                      0.000000768                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:50.950612	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:51.950565	                      0.000000772                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:52.950352	                      0.000000768                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:53.950181	                      0.000000768                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:54.950092	                      0.000000765                      0.000004329                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:55.950988	                      0.000000772                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:56.950791	                      0.000000772                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:57.950752	                      0.000000770                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:58.950590	                      0.000000772                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:59.951449	                      0.000000772                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:00.952356	                      0.000000770                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:01.952221	                      0.000000770                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:02.952136	                      0.000000768                      0.000004373                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:03.951975	                      0.000000772                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:04.951797	                      0.000000772                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:05.952809	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:06.952566	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:07.953452	                      0.000000768                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:08.953289	                      0.000000768                      0.000004373                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:09.953196	                      0.000000768                      0.000004395                      0.000003032                          5647.66                             0.18                           BadVal                           BadVal
10/22/2013 13:42:10.954172	                      0.000000770                      0.000004373                      0.000003054                         10004.42                             0.37                           BadVal                           BadVal
10/22/2013 13:42:11.953959	                      0.000000772                      0.000004395                      0.000003054                         10004.42                             0.37                           BadVal                           BadVal
10/22/2013 13:42:12.953833	                      0.000000768                      0.000004417                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:13.953731	                      0.000000772                      0.000004417                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:14.953571	                      0.000000772                      0.000004417                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:15.954406	                      0.000000772                      0.000004395                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:16.955395	                      0.000000770                      0.000004395                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:17.955223	                      0.000000768                      0.000004373                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:18.955091	                      0.000000770                      0.000004439                      0.000003032                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:19.954934	                      0.000000770                      0.000004373                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:20.955869	                      0.000000772                      0.000004373                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:21.956711	                      0.000000770                      0.000004373                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:22.956581	                      0.000000772                      0.000004373                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
... 12081 more lines ...
  524   Thursday, October 24, 2013, 11:32 Travis CaveSouth Hot-CellStandard OperationTM4no targetmodule move

TM#4 with no target has been moved from the conditioning station to the south hot cell.

  525   Thursday, October 24, 2013, 15:43 Anders MjosSouth Hot-CellStandard OperationTM4Ta#41Target conductance

The conductance check on the electrical check was found to be outside of accepted values for the TBHT at 7.0 mOhm. A successful attempt to reduce the conductance was made by re-tightening the bolts on the TGHT legs in the SHC. Grant operated the manipulator and torqued the bolts to about 1/8 of a turn with the air ratchet. The conductance across the TGHT (A-B) could be improved from 7.0 mOhm to 6.2 mOhm by re-tightening the bolts. The value is still somewhat higher than usual, but was deemed to be acceptable. Measurements attached.

Attachment 1: Ta#41_electrical_measurement_TGHT_in_SHC.pdf
Ta#41_electrical_measurement_TGHT_in_SHC.pdf
  526   Thursday, October 24, 2013, 15:54 Grant MinorSouth Hot-CellStandard OperationTM4Ta#41Target conductance

Anders Mjos wrote:

The conductance check on the electrical check was found to be outside of accepted values for the TBHT at 7.0 mOhm. A successful attempt to reduce the conductance was made by re-tightening the bolts on the TGHT legs in the SHC. Grant operated the manipulator and torqued the bolts to about 1/8 of a turn with the air ratchet. The conductance across the TGHT (A-B) could be improved from 7.0 mOhm to 6.2 mOhm by re-tightening the bolts. The value is still somewhat higher than usual, but was deemed to be acceptable. Measurements attached.

1. TGHT leg bolts were loosened, and resistance was measured very high, as expected.

2. TGHT leg bolts were then tightened, loosened, and tightened again, and the resistance improvement was then measured (from 7.0 mOhm to 6.2 mOhm).

3. Another attempt was then made to loosen and tighten to see if there would be further improvement.  The right bolt was loosened, but the left bolt was found to be quite stiff and was left as-is (not fully loosened) for fear of breaking the supporting insulator.  Both bolts were then re-tightened, and resistance was checked to be about the same as achieved during the previous loosening / tightening attempt (step 2 above).

To tighten the bolts in all cases: the air ratchet was used first to turn the bolts "air tight" (air pedal only, no manual force) and then with the air pedal held down, manual torque was applied to turn no more than 1/8th of a turn.

  527   Friday, October 25, 2013, 06:58 David WangSouth Hot-CellStandard OperationTM4 Leak check on TM4 target heat shield

Maico and I leak checked HS circuit after Chad installed the target. The circuit was a little bit difficult o pump down because of residue water moister inside. But once the moisture was pumped out, the pumping down was smooth and fast. The base leak rate 0.0xE-9 atm.cc/sec, base pressure 0.0xE-4 torr. Maico checked helium flow before the leak test. Then,He sprayed helium to all 3 VCR fiitings on target with 2 seconds on each one, He also flushed 10 seconds helium around the target. There were no any response during all these test time on leak detector.He checked the helium flow again after the test  and confirmed the helium flow.  The HS circuit is leak tight.

  528   Friday, October 25, 2013, 10:26 Travis CaveITWStandard OperationTM4Ta#41module move

TM#4 with Ta#41 has been moved from the south hot cell to the west target station.

  530   Friday, October 25, 2013, 14:09 Travis CaveSouth Hot-CellStandard OperationTM4Ta#41Target conductance

Anders Mjos wrote:

The conductance check on the electrical check was found to be outside of accepted values for the TBHT at 7.0 mOhm. A successful attempt to reduce the conductance was made by re-tightening the bolts on the TGHT legs in the SHC. Grant operated the manipulator and torqued the bolts to about 1/8 of a turn with the air ratchet. The conductance across the TGHT (A-B) could be improved from 7.0 mOhm to 6.2 mOhm by re-tightening the bolts. The value is still somewhat higher than usual, but was deemed to be acceptable. Measurements attached.

 The full electrical check was done on October 25th 2013. The results are in the attached PDF. The higher value of the conductance was dealt with see Anders Mjos elog entry for those details.

Attachment 1: TM#4_Ta#41_elec_test_SHC.PDF
TM#4_Ta#41_elec_test_SHC.PDF
  531   Thursday, October 31, 2013, 10:36 David WangITWStandard OperationTM4 I moved 5 shielding blocks from ITE to ITW.

I moved 5 shielding blocks from ITW to ITE. The ITW  is configured to take proton beam.

  563   Tuesday, December 03, 2013, 09:58 David WangITWStandard OperationTM4 I moved 5 shielding blocks from ITW to block storage area.

I moved 5 shielding blocks from ITW to block storage area.

  566   Wednesday, December 04, 2013, 10:44 Travis CaveSouth Hot-CellStandard OperationTM4Ta#41module move

TM#4 with Ta#41 has moved to the south hot cell, the move it self was uneventful but, the fields on the module are extremely high when lowering it down into the south hot cell the module had a maximum field of about 392mSv/hr. The shield plug was also installed remotely as well due to the 12mSv/hr field at the top of the west target station due to shine from the dump.

  567   Wednesday, December 04, 2013, 11:05 David WangITWStandard OperationTM4Ta41#I disconnected TM4 in ITW

I disconnected TM4 in ITW .The job took about 20minutes and I got 0.11 msv dose.

  568   Wednesday, December 04, 2013, 11:15 David WangITERepairTM4 New bolts are installed on ITE TP3.

I installed 8 new bolts(3/8-16 UNC x1.25  STL) on the ITE TP3. The ITE TP3 replacement job is done. Everything is connected back to the pump. and it is ready for starting.

  569   Wednesday, December 04, 2013, 13:57 chad fisherSouth Hot-CellStandard OperationTM4Ta #47Ta #47 Removed - broken bolt

Ta #47 has been removed from TM4.

One containment box cover bolt would not come out. Upon attempted removal with the stud remover the bolt sheared...which is not uncommon...just hasn't happened in many years...CBB being stuck or shearing.

Nine pin connector shows the typical "arcing" mark.

  570   Wednesday, December 04, 2013, 14:09 Travis CaveSouth Hot-CellStandard OperationTM4Ta#41Electrical check

Electrical check of TM#4 with Ta#41 post beam at the south hot cell. See PDF for details

Attachment 1: TM#4_Ta41_electest_SHC_PostBeam.PDF
TM#4_Ta41_electest_SHC_PostBeam.PDF
  571   Thursday, December 05, 2013, 12:04 Travis CaveITEStandard OperationTM4UC#8module move

TM#4 with UC#8 has been moved from the south hot cell to the east target station.

  572   Thursday, December 05, 2013, 12:51 Travis CaveSouth Hot-CellStandard OperationTM4UC#8 and no targetElectrical check

Electrical check was done on TM#4 without a target and with the UC#8 target on see attached PDF for results.

Attachment 1: TM#4_UC8_electest_SHC.PDF
TM#4_UC8_electest_SHC.PDF TM#4_UC8_electest_SHC.PDF
Attachment 2: TM#4_notarget_electest_SHC.PDF
TM#4_notarget_electest_SHC.PDF TM#4_notarget_electest_SHC.PDF
  573   Thursday, December 05, 2013, 14:55 David WangSouth Hot-CellStandard OperationTM4 Leak check on TM4 target heat shield

Chad and I leak checked TM4 heat shied water circuit at SHC. The pumping down was very good.Base leak rate 0.0xe-9 atm.cc/sec. BP 0.0xe-4torr. Sprayed helum twice on both VCR fittings.There is no response on leak detector.  The circuit is leak tight.

  574   Thursday, December 05, 2013, 14:57 David WangITEStandard OperationTM4  Connected TM4 in ITW

I connected TM4 in ITE. All turbo pumps have been started and wok fine including new TP3. Everything is good so far.

  577   Monday, December 09, 2013, 14:47 David WangITEStandard OperationTM4 I moved 5 shielding blocks from block storage area to ITE.

I moved 5 shielding blocks to ITE. The ITE is configured to take proton beam.

ELOG V2.9.2-2455