ID |
Date |
Author |
Category |
Type |
Module |
Target/Number |
Subject |
546
|
Monday, November 18, 2013, 16:42 |
Bevan Moss | Conditioning Station | Standard Operation | TM2 | | HV Testing |
The Glory of TM2 continues 100V at a time. Today I brought the module to 46kV and left it there for 1 hour. During this time there was only 1 spark. I then continues at up to 53kV. At this voltage the canbus continues to be temperamental when the module sparks. The module is still conditioning and I will continue more tomorrow. Attached is the dumped data and a screen shot of the conditioning from 46kV to 53kV. |
Attachment 1: the_glory_of_TM2.JPG
|
|
Attachment 2: 18112013_TM2_No_source_tray_HV_Test.txt
|
Time TCS:IG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:BIAS:RDVOL [V] TCS:BIAS:RDCUR [uA] TCS:EL:RDVOL [V] TCS:EL:RDCUR [mA]
11/18/2013 11:56:33.67635 0.000000350 BadVal BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:34.66886 0.000000350 BadVal BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:35.66751 0.000000350 BadVal BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:36.67660 0.000000352 BadVal BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:37.67534 0.000000352 BadVal BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:38.68405 0.000000352 BadVal BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:39.68261 0.000000352 0.000003758 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:40.68163 0.000000350 0.000003780 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:41.68032 0.000000350 0.000003758 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:42.67903 0.000000354 0.000003758 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:43.68805 0.000000350 0.000003780 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:44.68623 0.000000350 0.000003758 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:45.68500 0.000000350 0.000003780 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:46.69372 0.000000350 0.000003780 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:47.69322 0.000000352 0.000003780 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:48.69129 0.000000352 0.000003758 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:49.69014 0.000000352 0.000003780 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:50.68910 0.000000350 0.000003758 BadVal BadVal BadVal BadVal BadVal
11/18/2013 11:56:51.68802 0.000000352 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:56:52.68661 0.000000350 0.000003780 0.000002000 BadVal BadVal BadVal BadVal
11/18/2013 11:56:53.68525 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:56:54.68443 0.000000354 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:56:55.68299 0.000000354 0.000003780 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:56:56.69356 0.000000350 0.000003780 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:56:57.69988 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:56:58.69998 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:56:59.70818 0.000000352 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:57:00.70672 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:01.71518 0.000000354 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:02.71393 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:03.72305 0.000000352 0.000003780 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:04.72168 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:05.71991 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:06.72879 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:07.72774 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:08.72786 0.000000350 0.000003780 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:09.73521 0.000000350 0.000003780 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:10.73360 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:11.73271 0.000000348 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:12.73140 0.000000352 0.000003802 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:57:13.72987 0.000000352 0.000003802 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:14.72862 0.000000352 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:15.73998 0.000000350 0.000003780 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:16.74679 0.000000352 0.000003780 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:17.74555 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:18.74357 0.000000352 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:19.74415 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:20.75099 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:21.76009 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:22.75889 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:23.75773 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:24.167647 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:25.167497 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:26.168548 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:27.168249 0.000000354 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:28.168091 0.000000354 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:29.168174 0.000000348 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:30.167873 0.000000357 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:31.168824 0.000000352 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:32.168589 0.000000352 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:33.168490 0.000000352 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:57:34.168368 0.000000348 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:35.169260 0.000000350 0.000003780 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:36.170079 0.000000350 0.000003758 0.000002000 BadVal BadVal BadVal BadVal
11/18/2013 11:57:37.169962 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:57:38.169833 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:39.169741 0.000000348 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:40.169577 0.000000348 0.000003780 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:57:41.170683 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:42.171478 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:43.171240 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:44.171080 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:45.171080 0.000000352 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:57:46.171861 0.000000354 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:47.171901 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:48.173683 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:57:49.173532 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:50.173355 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:51.174221 0.000000350 0.000003780 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:57:52.174097 0.000000350 0.000003780 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:57:53.173980 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:54.173846 0.000000352 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:55.173701 0.000000352 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:56.174624 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:57.174550 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:58.175484 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:57:59.175364 0.000000352 0.000003780 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:00.176142 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:01.176991 0.000000348 0.000003780 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:02.176907 0.000000350 0.000003780 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:03.176736 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:04.176560 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:05.176444 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:06.176439 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:07.176466 0.000000352 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:08.176115 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:09.175970 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:10.175854 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:11.176710 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:12.176587 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:13.176518 0.000000352 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:14.177305 0.000000352 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:15.178256 0.000000352 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:16.178161 0.000000346 0.000003780 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:17.177934 0.000000346 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:18.177862 0.000000348 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:19.177767 0.000000350 0.000003780 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:20.178771 0.000000352 0.000003780 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:21.179458 0.000000348 0.000003780 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:22.180299 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:23.180173 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:24.180086 0.000000352 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:25.180011 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:26.180879 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:27.180711 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:28.180607 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:29.180448 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:30.180303 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:31.181202 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:32.181076 0.000000346 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:33.180951 0.000000348 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:34.180824 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:35.180722 0.000000352 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:36.180621 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:37.180619 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:38.181373 0.000000352 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:39.181195 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:40.181042 0.000000348 0.000003736 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:41.181989 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:42.181796 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:43.181704 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:44.182677 0.000000350 0.000003758 0.000002087 BadVal BadVal BadVal BadVal
11/18/2013 11:58:45.182451 0.000000346 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:46.183316 0.000000348 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:48.803335 0.000000352 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:49.803216 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:50.802868 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:51.802603 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:52.803455 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:53.803339 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:54.803283 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:58:55.804102 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:58:56.803969 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:58:57.803933 0.000000348 0.000003758 0.000002000 BadVal BadVal BadVal BadVal
11/18/2013 11:58:58.803707 0.000000348 0.000003758 0.000002000 BadVal BadVal BadVal BadVal
11/18/2013 11:58:59.803667 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:00.803690 0.000000348 0.000003758 0.000002000 BadVal BadVal BadVal BadVal
11/18/2013 11:59:01.803354 0.000000350 0.000003758 0.000002000 BadVal BadVal BadVal BadVal
11/18/2013 11:59:02.803204 0.000000350 0.000003780 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:03.803102 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:04.802982 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:05.803883 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:06.803746 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:07.803569 0.000000348 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:08.803499 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:09.803404 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:10.803237 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:11.803090 0.000000348 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:12.802976 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:13.802824 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:14.802723 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:15.802654 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:16.802447 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:17.802315 0.000000348 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:18.802355 0.000000348 0.000003736 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:19.802084 0.000000348 0.000003736 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:20.802934 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:21.802850 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:22.802712 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:23.802672 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:24.802472 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:25.802310 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:26.802213 0.000000352 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:28.87230 0.000000350 0.000003736 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:29.86904 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:30.86799 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:31.87780 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:32.87546 0.000000348 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:33.87451 0.000000350 0.000003736 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:34.87271 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:35.87150 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:36.88072 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:37.87900 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:38.87899 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:39.87677 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:40.88567 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:41.89421 0.000000346 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:42.89294 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:43.89145 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:44.89053 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:45.88930 0.000000350 0.000003780 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:46.89854 0.000000352 0.000003736 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:47.89750 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:48.89545 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:49.90415 0.000000350 0.000003736 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:50.90300 0.000000348 0.000003736 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:51.91305 0.000000350 0.000003736 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 11:59:52.91017 0.000000350 0.000003736 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 11:59:53.90976 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:54.91865 0.000000350 0.000003758 0.000002087 BadVal BadVal BadVal BadVal
11/18/2013 11:59:55.92687 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:56.93563 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:57.93420 0.000000346 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:58.93286 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 11:59:59.93135 0.000000348 0.000003736 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 12:00:00.93026 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 12:00:01.93957 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 12:00:02.93759 0.000000348 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:03.93679 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 12:00:04.93605 0.000000352 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:05.93414 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 12:00:06.94302 0.000000348 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 12:00:07.94146 0.000000348 0.000003736 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:08.94029 0.000000348 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:09.93914 0.000000350 0.000003780 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:10.93783 0.000000348 0.000003736 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:11.93656 0.000000348 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:12.93579 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:13.93443 0.000000352 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:14.93255 0.000000352 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 12:00:15.93164 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 12:00:16.94024 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:17.93919 0.000000348 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:18.93782 0.000000350 0.000003758 0.000002065 BadVal BadVal BadVal BadVal
11/18/2013 12:00:19.93656 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 12:00:20.93610 0.000000348 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 12:00:21.94365 0.000000348 0.000003736 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 12:00:22.94271 0.000000350 0.000003758 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 12:00:23.94121 0.000000350 0.000003758 0.000002043 BadVal BadVal BadVal BadVal
11/18/2013 12:00:24.94077 0.000000348 0.000003802 0.000002021 BadVal BadVal BadVal BadVal
11/18/2013 12:00:25.101301 0.000000348 0.000003736 0.000002000 29.75 BadVal BadVal BadVal
11/18/2013 12:00:26.101770 0.000000352 0.000003758 0.000002043 28.61 BadVal BadVal BadVal
11/18/2013 12:00:27.628314 0.000000348 0.000003758 0.000002043 28.61 BadVal BadVal BadVal
11/18/2013 12:00:28.628508 0.000000352 0.000003758 0.000002021 28.61 BadVal BadVal BadVal
11/18/2013 12:00:29.629329 0.000000350 0.000003758 0.000002043 28.61 0.48 BadVal BadVal
11/18/2013 12:00:30.629181 0.000000350 0.000003758 0.000002043 29.75 0.48 BadVal BadVal
11/18/2013 12:00:31.630128 0.000000348 0.000003736 0.000002043 29.75 0.48 BadVal BadVal
11/18/2013 12:00:32.629945 0.000000348 0.000003758 0.000002043 28.61 0.48 BadVal BadVal
11/18/2013 12:00:33.629793 0.000000348 0.000003736 0.000002043 28.61 0.48 BadVal BadVal
11/18/2013 12:00:34.658234 0.000000348 0.000003758 0.000002043 28.61 0.48 BadVal BadVal
11/18/2013 12:00:35.657546 0.000000348 0.000003758 0.000002043 28.61 0.48 BadVal BadVal
11/18/2013 12:00:36.657419 0.000000348 0.000003758 0.000002087 27.46 0.48 6.10 BadVal
11/18/2013 12:00:37.657311 0.000000348 0.000003736 0.000002043 27.46 0.48 6.10 BadVal
11/18/2013 12:00:38.657194 0.000000348 0.000003736 0.000002043 29.75 0.48 6.10 BadVal
11/18/2013 12:00:39.658139 0.000000348 0.000003736 0.000002043 29.75 0.48 6.10 BadVal
11/18/2013 12:00:42.44788 0.000000348 0.000003758 0.000002021 28.61 0.48 6.10 BadVal
11/18/2013 12:00:43.44671 0.000000348 0.000003758 0.000002021 28.61 0.48 6.10 0.01
11/18/2013 12:00:44.44499 0.000000348 0.000003758 0.000002065 28.61 0.48 5.49 0.01
11/18/2013 12:00:45.44528 0.000000350 0.000003758 0.000002065 28.61 0.48 5.49 0.01
11/18/2013 12:00:46.44300 0.000000348 0.000003758 0.000002065 28.61 0.48 6.10 0.01
11/18/2013 12:00:47.44150 0.000000346 0.000003758 0.000002065 28.61 0.48 6.10 0.01
11/18/2013 12:00:48.43366 0.000000346 0.000003758 0.000002065 29.75 0.48 6.10 0.01
11/18/2013 12:00:49.44059 0.000000348 0.000003758 0.000002065 29.75 0.48 6.10 0.01
11/18/2013 12:00:50.43894 0.000000350 0.000003758 0.000002043 28.61 0.48 6.10 0.01
11/18/2013 12:00:51.43674 0.000000348 0.000003758 0.000002065 28.61 0.48 6.10 0.01
11/18/2013 12:00:52.44636 0.000000348 0.000003758 0.000002065 28.61 0.48 6.10 0.01
11/18/2013 12:00:53.44585 0.000000348 0.000003758 0.000002065 28.61 0.48 6.10 0.01
11/18/2013 12:00:54.45302 0.000000352 0.000003758 0.000002065 28.61 0.48 6.10 0.01
11/18/2013 12:00:55.44355 0.000000352 0.000003758 0.000002043 28.61 0.48 6.10 0.01
11/18/2013 12:00:56.44002 0.000000352 0.000003780 0.000002065 29.75 0.48 6.10 0.01
11/18/2013 12:00:57.44147 0.000000352 0.000003736 0.000002065 29.75 0.48 6.10 0.01
11/18/2013 12:00:58.44820 0.000000348 0.000003758 0.000002065 29.75 0.48 6.10 0.01
11/18/2013 12:00:59.44598 0.000000348 0.000003758 0.000002021 29.75 0.48 6.10 0.01
11/18/2013 12:01:00.44519 0.000000350 0.000003758 0.000002021 29.75 0.48 6.10 0.01
11/18/2013 12:01:01.44421 0.000000348 0.000003758 0.000002000 29.75 0.48 6.10 0.01
11/18/2013 12:01:02.44217 0.000000348 0.000003758 0.000002000 29.75 0.48 6.10 0.01
11/18/2013 12:01:03.44128 0.000000348 0.000003736 0.000002043 29.75 0.48 6.10 0.01
11/18/2013 12:01:04.43981 0.000000348 0.000003736 0.000002021 27.46 0.48 6.10 0.01
11/18/2013 12:01:05.43875 0.000000348 0.000003736 0.000002043 27.46 0.48 6.10 0.01
11/18/2013 12:01:06.43730 0.000000348 0.000003758 0.000002065 28.61 0.48 6.10 0.01
11/18/2013 12:01:07.43676 0.000000348 0.000003758 0.000002065 28.61 0.48 6.10 0.01
11/18/2013 12:01:08.43483 0.000000348 0.000003758 0.000002065 28.61 0.48 6.10 0.01
11/18/2013 12:01:10.527029 0.000000350 0.000003758 0.000002043 27.46 0.48 6.10 0.01
11/18/2013 12:01:11.526244 0.000000348 0.000003758 0.000002043 29.75 0.48 6.10 0.01
11/18/2013 12:01:12.526954 0.000000348 0.000003736 0.000002065 29.75 0.48 6.10 0.01
11/18/2013 12:01:13.526789 0.000000348 0.000003736 0.000002065 28.61 0.48 6.10 0.01
11/18/2013 12:01:14.526783 0.000000348 0.000003758 0.000002043 28.61 0.48 6.10 0.01
11/18/2013 12:01:15.526585 0.000000350 0.000003736 0.000002065 29.75 0.48 6.10 0.01
11/18/2013 12:01:17.268629 0.000000350 0.000003758 0.000002043 27.46 0.48 6.10 0.01
11/18/2013 12:01:18.269323 0.000000348 0.000003758 0.000002065 27.46 0.48 6.10 0.01
11/18/2013 12:01:19.269066 0.000000348 0.000003758 0.000002043 29.75 0.48 6.10 0.01
11/18/2013 12:01:20.269024 0.000000348 0.000003758 0.000002043 29.75 0.48 6.10 0.01
11/18/2013 12:01:21.268809 0.000000348 0.000003758 0.000002065 27.46 0.48 6.10 0.01
11/18/2013 12:01:22.268839 0.000000350 0.000003736 0.000002043 8.01 0.36 6.10 0.01
11/18/2013 12:01:23.269588 0.000000350 0.000003758 0.000002065 8.01 0.36 6.10 0.01
11/18/2013 12:01:24.269513 0.000000348 0.000003758 0.000002043 8.01 0.73 6.10 0.01
11/18/2013 12:01:25.269349 0.000000346 0.000003736 0.000002021 8.01 0.73 6.10 0.01
11/18/2013 12:01:26.269482 0.000000346 0.000003758 0.000002043 5.72 0.61 6.10 0.01
11/18/2013 12:01:27.270296 0.000000350 0.000003758 0.000002043 5.72 0.61 6.10 0.01
11/18/2013 12:01:28.269961 0.000000350 0.000003736 0.000002043 10.29 0.85 6.10 0.01
11/18/2013 12:01:29.269871 0.000000348 0.000003758 0.000002043 10.29 0.85 6.10 0.01
11/18/2013 12:01:30.269726 0.000000350 0.000003736 0.000002043 8.01 0.85 6.10 0.01
11/18/2013 12:01:31.369724 0.000000348 0.000003780 0.000002043 8.01 0.85 6.10 0.01
11/18/2013 12:01:32.369423 0.000000348 0.000003758 0.000002065 10.29 0.73 6.10 0.01
11/18/2013 12:01:33.370375 0.000000350 0.000003758 0.000002065 10.29 0.73 6.10 0.01
11/18/2013 12:01:34.370213 0.000000348 0.000003780 0.000002043 11.44 0.73 6.10 0.01
11/18/2013 12:01:35.370088 0.000000350 0.000003780 0.000002043 11.44 0.73 6.10 0.01
11/18/2013 12:01:36.369921 0.000000350 0.000003758 0.000002043 4.57 0.85 6.10 0.01
11/18/2013 12:01:37.585188 0.000000348 0.000003758 0.000002043 4.57 0.85 6.10 0.01
... 15829 more lines ...
|
547
|
Monday, November 18, 2013, 16:44 |
Bevan Moss | Conditioning Station | Standard Operation | | | Testing of cooling package |
I have tested all of the compressors for TCS. All are operational and cycled as they should. |
549
|
Tuesday, November 19, 2013, 14:24 |
David Wang | ITE | Repair | | | ITE TP3 |
Hi all, The old ITE TP3 pump is moved out and the new pump is in postion .Since this time I used a new holding ring(1 piece) insead of old 2 pieces holding ring which are thicker than new ring, the old holding bolts are a little bit too long for the thread holes on the ITE exit 1. I have to find the right length bolts for this new holding ring. The pump is in position,and all connection are done except the holding bolts. I will put the new bolts on and tight them when I connect the TM4 in ITE next time. So, If I am not here at that time and you need to connect TM4 and start the pumps in ITE, please check all the bolts are tighted before you do anything.
|
550
|
Tuesday, November 19, 2013, 16:55 |
Bevan Moss | Conditioning Station | Standard Operation | TM2 | | HV conditioning |
HV conditioning of TM2 continued today. At ~53.5kV the module started to spark externally to the HV cover. This is the first time the cover has been tested to this high of a voltage due to the limitations of the modules. As such for the conditioning station to achieve 60kV while keeping the target hall open of personnel the cover and cage will need to be modified. To continue with HV testing of TM2 the cover was removed and the target hall locked out as per the procedure covered in Document 70039 "ISAC Conditioning Station: First Lock-Out and High-Voltage "ON". With the cover off the module was able to achieve ~56.7kV without the Einzel lens on. Eliminate the Einzel lens as a potential source of sparking it was brought to 25kV while the module continued conditioning. Maximum voltage achieve under this configuration was 57.1kV. Increments are now 50V steps. The Canbus continues to be very sensitive to any sparking and is slowing the process down considerably. It does however appear that the module is continuing to condition. I will continue tomorrow after the module moves to attempt to reach 60kV and hold it for 1 hour. |
Attachment 1: external_sparking.JPG
|
|
Attachment 2: 19112013_HV_conditioning_TM2.JPG
|
|
Attachment 3: 19112013_TM2_No_source_tray_HV_Test_no_cover.txt
|
Time TCS:IG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:BIAS:RDVOL [V] TCS:BIAS:RDCUR [uA] TCS:EL:RDVOL [V] TCS:EL:RDCUR [mA]
11/19/2013 14:05:53.354722 0.000000302 0.000003362 0.000001516 11.44 0.18 4.88 0.03
11/19/2013 14:05:54.354616 0.000000300 0.000003362 0.000001516 18.31 0.18 4.88 0.03
11/19/2013 14:05:55.354491 0.000000304 0.000003340 0.000001516 18.31 0.18 4.88 0.03
11/19/2013 14:05:56.355471 0.000000304 0.000003340 0.000001538 18.31 0.18 4.88 0.03
11/19/2013 14:05:57.355260 0.000000304 0.000003362 0.000001538 21.74 0.18 4.88 0.03
11/19/2013 14:05:58.356309 0.000000304 0.000003362 0.000001516 21.74 0.18 4.88 0.03
11/19/2013 14:05:59.355939 0.000000304 0.000003362 0.000001516 25.17 0.30 4.88 0.03
11/19/2013 14:06:00.356012 0.000000302 0.000003362 0.000001538 25.17 0.30 4.88 0.03
11/19/2013 14:06:01.356728 0.000000300 0.000003362 0.000001538 26.32 0.30 4.88 0.03
11/19/2013 14:06:02.356720 0.000000304 0.000003362 0.000001516 26.32 0.30 4.88 0.03
11/19/2013 14:06:03.356444 0.000000304 0.000003362 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:04.357380 0.000000302 0.000003362 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:05.357218 0.000000302 0.000003362 0.000001538 26.32 0.30 5.49 0.03
11/19/2013 14:06:06.358329 0.000000306 0.000003362 0.000001538 26.32 0.30 5.49 0.03
11/19/2013 14:06:07.359140 0.000000302 0.000003384 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:08.358814 0.000000302 0.000003340 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:09.358730 0.000000306 0.000003362 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:10.358605 0.000000304 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:11.359545 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:12.359312 0.000000302 0.000003362 0.000001516 27.46 0.30 5.49 0.03
11/19/2013 14:06:13.359243 0.000000304 0.000003384 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:14.359103 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:15.359040 0.000000304 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:16.359868 0.000000302 0.000003362 0.000001516 27.46 0.30 5.49 0.03
11/19/2013 14:06:17.359724 0.000000304 0.000003362 0.000001516 27.46 0.30 5.49 0.03
11/19/2013 14:06:18.359599 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:19.359585 0.000000304 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:20.359298 0.000000304 0.000003384 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:21.360304 0.000000304 0.000003384 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:22.360120 0.000000304 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:23.359987 0.000000302 0.000003340 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:24.359901 0.000000302 0.000003362 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:25.359840 0.000000304 0.000003362 0.000001516 27.46 0.30 5.49 0.03
11/19/2013 14:06:26.360642 0.000000300 0.000003340 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:27.360471 0.000000300 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:28.359710 0.000000306 0.000003340 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:29.360203 0.000000304 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:30.360083 0.000000302 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:31.360917 0.000000302 0.000003340 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:32.360825 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:33.360728 0.000000304 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:34.360551 0.000000304 0.000003362 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:35.360556 0.000000304 0.000003340 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:36.361435 0.000000302 0.000003340 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:37.361170 0.000000302 0.000003384 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:38.361078 0.000000306 0.000003340 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:39.360960 0.000000304 0.000003362 0.000001560 28.61 0.30 5.49 0.03
11/19/2013 14:06:40.360827 0.000000302 0.000003362 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:41.361763 0.000000302 0.000003362 0.000001560 27.46 0.30 5.49 0.03
11/19/2013 14:06:42.362590 0.000000302 0.000003362 0.000001560 28.61 0.30 5.49 0.03
11/19/2013 14:06:43.362450 0.000000304 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:44.362283 0.000000304 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:45.363190 0.000000302 0.000003340 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:46.364029 0.000000302 0.000003362 0.000001494 28.61 0.30 5.49 0.03
11/19/2013 14:06:47.363963 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:48.363929 0.000000304 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:49.364676 0.000000304 0.000003340 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:50.364535 0.000000304 0.000003340 0.000001560 27.46 0.30 5.49 0.03
11/19/2013 14:06:51.365463 0.000000300 0.000003362 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:06:52.366307 0.000000300 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:06:53.366193 0.000000308 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:54.366069 0.000000304 0.000003340 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:55.365938 0.000000306 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:56.366809 0.000000304 0.000003362 0.000001516 29.75 0.30 5.49 0.03
11/19/2013 14:06:57.366654 0.000000304 0.000003362 0.000001538 29.75 0.30 5.49 0.03
11/19/2013 14:06:58.367523 0.000000304 0.000003384 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:06:59.367430 0.000000304 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:07:00.367278 0.000000304 0.000003340 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:01.367220 0.000000306 0.000003340 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:07:02.367054 0.000000302 0.000003340 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:03.366900 0.000000302 0.000003340 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:04.366837 0.000000304 0.000003340 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:07:05.366830 0.000000304 0.000003362 0.000001560 27.46 0.30 5.49 0.03
11/19/2013 14:07:06.367680 0.000000300 0.000003340 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:07:07.367422 0.000000302 0.000003362 0.000001494 28.61 0.30 5.49 0.03
11/19/2013 14:07:08.367307 0.000000308 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:07:09.367180 0.000000302 0.000003362 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:07:10.367078 0.000000304 0.000003362 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:07:11.368047 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:12.367770 0.000000302 0.000003362 0.000001560 28.61 0.30 5.49 0.03
11/19/2013 14:07:13.367637 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:14.367544 0.000000302 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:07:15.367429 0.000000304 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:16.368326 0.000000302 0.000003362 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:07:17.368176 0.000000306 0.000003362 0.000001516 27.46 0.30 5.49 0.03
11/19/2013 14:07:18.368039 0.000000302 0.000003362 0.000001538 27.46 0.30 5.49 0.03
11/19/2013 14:07:19.367933 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:20.367835 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:21.368721 0.000000300 0.000003340 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:22.368549 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:23.368413 0.000000306 0.000003384 0.000001516 28.61 0.30 5.49 0.03
11/19/2013 14:07:24.368292 0.000000302 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:25.368197 0.000000304 0.000003362 0.000001538 29.75 0.30 5.49 0.03
11/19/2013 14:07:26.369153 0.000000304 0.000003362 0.000001538 29.75 0.30 5.49 0.03
11/19/2013 14:07:27.369877 0.000000304 0.000003362 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:28.369786 0.000000302 0.000003340 0.000001538 28.61 0.30 5.49 0.03
11/19/2013 14:07:29.369767 0.000000306 0.000003340 0.000001538 29.75 0.30 5.49 0.03
11/19/2013 14:07:30.369531 0.000000302 0.000003362 0.000001516 29.75 0.30 5.49 0.03
11/19/2013 14:07:31.370442 0.000000304 0.000003362 0.000001560 29.75 0.30 5.49 0.03
11/19/2013 14:07:32.370291 0.000000302 0.000003362 0.000001538 29.75 0.30 5.49 0.03
11/19/2013 14:07:33.370168 0.000000304 0.000003362 0.000001560 28.61 0.30 5.49 0.03
11/19/2013 14:07:34.369996 0.000000304 0.000003362 0.000001560 28.61 0.30 5.49 0.03
11/19/2013 14:07:35.369937 0.000000306 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:07:36.370838 0.000000306 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:07:37.370668 0.000000302 0.000003362 0.000001560 29.75 0.42 5.49 0.03
11/19/2013 14:07:38.370749 0.000000304 0.000003362 0.000001582 29.75 0.42 5.49 0.03
11/19/2013 14:07:39.371415 0.000000302 0.000003384 0.000001560 29.75 0.42 5.49 0.03
11/19/2013 14:07:40.371286 0.000000304 0.000003384 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:07:41.372115 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:07:42.371999 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:07:43.371914 0.000000306 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:07:44.371842 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:07:45.371657 0.000000302 0.000003362 0.000001560 28.61 0.42 5.49 0.03
11/19/2013 14:07:46.372526 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:07:47.372407 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:07:48.372325 0.000000306 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:07:49.372151 0.000000306 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:07:50.373021 0.000000302 0.000003362 0.000001560 28.61 0.42 5.49 0.03
11/19/2013 14:07:51.373956 0.000000304 0.000003362 0.000001560 27.46 0.42 5.49 0.03
11/19/2013 14:07:52.373746 0.000000304 0.000003384 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:07:53.373706 0.000000304 0.000003362 0.000001538 29.75 0.42 5.49 0.03
11/19/2013 14:07:54.373541 0.000000302 0.000003362 0.000001538 29.75 0.42 5.49 0.03
11/19/2013 14:07:55.373384 0.000000308 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:07:56.373439 0.000000304 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:07:57.373107 0.000000304 0.000003362 0.000001538 29.75 0.42 5.49 0.03
11/19/2013 14:07:58.373036 0.000000306 0.000003384 0.000001538 29.75 0.42 5.49 0.03
11/19/2013 14:07:59.372863 0.000000306 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:00.372736 0.000000306 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:01.373696 0.000000306 0.000003362 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:08:02.373648 0.000000302 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:03.374534 0.000000300 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:04.375263 0.000000308 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:05.376101 0.000000308 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:06.377066 0.000000297 0.000003362 0.000001494 28.61 0.42 5.49 0.03
11/19/2013 14:08:07.376910 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:08.376768 0.000000304 0.000003318 0.000001560 29.75 0.42 5.49 0.03
11/19/2013 14:08:09.376642 0.000000306 0.000003362 0.000001538 29.75 0.42 5.49 0.03
11/19/2013 14:08:10.376520 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:11.376582 0.000000300 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:12.376266 0.000000300 0.000003340 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:13.376238 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:14.375983 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:15.375886 0.000000304 0.000003384 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:16.375820 0.000000306 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:08:17.375626 0.000000304 0.000003340 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:08:18.375507 0.000000302 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:19.375369 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:20.376380 0.000000304 0.000003362 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:08:21.377197 0.000000304 0.000003340 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:08:22.377109 0.000000304 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:23.376905 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:24.376781 0.000000304 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:25.377666 0.000000304 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:26.377670 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:27.377464 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:28.378245 0.000000300 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:29.378131 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:30.378152 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:31.377926 0.000000306 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:32.377773 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:33.377608 0.000000304 0.000003340 0.000001560 28.61 0.42 5.49 0.03
11/19/2013 14:08:34.378551 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:35.378336 0.000000304 0.000003340 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:36.379229 0.000000304 0.000003340 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:08:37.379143 0.000000306 0.000003340 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:08:38.380035 0.000000304 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:08:39.379852 0.000000304 0.000003362 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:08:40.379853 0.000000304 0.000003340 0.000001538 29.75 0.42 5.49 0.03
11/19/2013 14:08:41.380667 0.000000300 0.000003362 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:08:42.380496 0.000000302 0.000003340 0.000001582 28.61 0.42 5.49 0.03
11/19/2013 14:08:43.381497 0.000000306 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:44.382284 0.000000306 0.000003340 0.000001494 29.75 0.42 5.49 0.03
11/19/2013 14:08:45.382081 0.000000306 0.000003362 0.000001494 29.75 0.42 5.49 0.03
11/19/2013 14:08:46.382969 0.000000306 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:47.382888 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:48.382765 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:49.382582 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:50.382483 0.000000306 0.000003362 0.000001494 28.61 0.42 5.49 0.03
11/19/2013 14:08:51.383390 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:52.383236 0.000000306 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:53.383142 0.000000306 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:08:54.382977 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:55.383033 0.000000302 0.000003362 0.000001560 28.61 0.42 5.49 0.03
11/19/2013 14:08:56.383746 0.000000302 0.000003384 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:08:57.383610 0.000000304 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:08:58.384517 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:08:59.384360 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:00.384233 0.000000306 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:01.384098 0.000000306 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:02.384008 0.000000302 0.000003340 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:03.383841 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:04.384838 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:05.384849 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:06.385552 0.000000306 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:07.385371 0.000000306 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:08.385188 0.000000306 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:09.385098 0.000000302 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:09:10.384964 0.000000302 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:09:11.385810 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:12.385870 0.000000306 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:13.386593 0.000000304 0.000003384 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:14.386563 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:15.386310 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:16.387331 0.000000304 0.000003340 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:17.387108 0.000000300 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:18.386975 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:19.386848 0.000000304 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:20.386684 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:21.387583 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:22.387469 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:23.387339 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:24.387222 0.000000304 0.000003362 0.000001560 28.61 0.42 5.49 0.03
11/19/2013 14:09:25.387167 0.000000306 0.000003362 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:09:26.388077 0.000000302 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:09:27.387859 0.000000304 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:09:28.387670 0.000000304 0.000003384 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:09:29.387547 0.000000304 0.000003384 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:30.387462 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:31.388291 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:32.388300 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:33.388040 0.000000302 0.000003384 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:34.387967 0.000000308 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:35.387846 0.000000304 0.000003318 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:36.388795 0.000000306 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:37.389717 0.000000302 0.000003384 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:09:38.389408 0.000000302 0.000003340 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:09:39.389291 0.000000302 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:40.389397 0.000000304 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:41.390033 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:42.389915 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:43.389825 0.000000306 0.000003384 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:09:44.389697 0.000000304 0.000003384 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:09:45.389571 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:46.390485 0.000000302 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:47.391343 0.000000304 0.000003340 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:48.391159 0.000000304 0.000003340 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:49.391072 0.000000302 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:50.390947 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:51.391775 0.000000304 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:09:52.391202 0.000000304 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:09:53.391826 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:54.392406 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:55.392281 0.000000304 0.000003384 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:09:56.393178 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:57.393028 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:09:58.392904 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:09:59.392947 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:00.392649 0.000000302 0.000003384 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:10:01.393587 0.000000302 0.000003340 0.000001538 29.75 0.42 5.49 0.03
11/19/2013 14:10:02.393437 0.000000300 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:03.393427 0.000000304 0.000003384 0.000001494 28.61 0.42 5.49 0.03
11/19/2013 14:10:04.393216 0.000000302 0.000003362 0.000001494 29.75 0.42 5.49 0.03
11/19/2013 14:10:05.393073 0.000000302 0.000003362 0.000001538 29.75 0.42 5.49 0.03
11/19/2013 14:10:06.392979 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:07.392808 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:08.392747 0.000000302 0.000003362 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:10:09.393600 0.000000302 0.000003340 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:10:10.393431 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:11.394321 0.000000304 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:12.394255 0.000000302 0.000003362 0.000001582 27.46 0.42 5.49 0.03
11/19/2013 14:10:13.394061 0.000000306 0.000003340 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:10:14.393935 0.000000304 0.000003340 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:10:15.394815 0.000000304 0.000003340 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:10:16.395754 0.000000304 0.000003362 0.000001494 28.61 0.42 5.49 0.03
11/19/2013 14:10:17.395575 0.000000302 0.000003318 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:18.395428 0.000000304 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:19.395326 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:20.396197 0.000000306 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:21.397060 0.000000304 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:22.397959 0.000000304 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:10:23.397760 0.000000304 0.000003362 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:10:24.397660 0.000000304 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:10:25.397555 0.000000306 0.000003362 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:10:26.397473 0.000000304 0.000003362 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:10:27.397292 0.000000304 0.000003362 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:10:28.397275 0.000000304 0.000003362 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:10:29.397064 0.000000302 0.000003362 0.000001516 27.46 0.42 5.49 0.03
11/19/2013 14:10:30.397950 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:31.398916 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:32.398700 0.000000304 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:33.398565 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:34.398475 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:35.399271 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:36.400292 0.000000300 0.000003384 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:37.400283 0.000000300 0.000003384 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:38.399877 0.000000300 0.000003362 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:10:39.400813 0.000000302 0.000003362 0.000001516 29.75 0.42 5.49 0.03
11/19/2013 14:10:40.401650 0.000000302 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:41.402517 0.000000302 0.000003362 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:42.403427 0.000000302 0.000003384 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:43.403303 0.000000304 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:44.403147 0.000000302 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:45.403017 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:46.403927 0.000000304 0.000003362 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:10:47.403779 0.000000306 0.000003340 0.000001538 27.46 0.42 5.49 0.03
11/19/2013 14:10:48.404762 0.000000304 0.000003340 0.000001516 28.61 0.42 5.49 0.03
11/19/2013 14:10:49.405527 0.000000302 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:50.405406 0.000000300 0.000003362 0.000001538 28.61 0.42 5.49 0.03
11/19/2013 14:10:51.405266 0.000000304 0.000003340 0.000001538 28.61 0.42 5.49 0.03
... 9169 more lines ...
|
Attachment 4: 19112013_TM2_No_source_tray_HV_Test.txt
|
Time TCS:IG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:BIAS:RDVOL [V] TCS:BIAS:RDCUR [uA] TCS:EL:RDVOL [V] TCS:EL:RDCUR [mA]
11/19/2013 10:41:01.318511 0.000000302 BadVal BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:02.317614 0.000000304 BadVal BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:03.317465 0.000000304 BadVal BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:04.317355 0.000000304 BadVal BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:05.402487 0.000000304 BadVal BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:06.403328 0.000000302 BadVal BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:07.403004 0.000000302 BadVal BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:08.402906 0.000000302 BadVal BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:09.402698 0.000000302 BadVal BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:10.402606 0.000000304 0.000003384 BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:11.403668 0.000000304 0.000003384 BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:12.404343 0.000000302 0.000003384 BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:13.404485 0.000000306 0.000003384 BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:14.404091 0.000000300 0.000003384 BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:15.404261 0.000000302 0.000003384 BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:16.404970 0.000000300 0.000003384 BadVal BadVal BadVal BadVal BadVal
11/19/2013 10:41:17.405939 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:18.405596 0.000000304 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:19.405470 0.000000304 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:20.405591 0.000000304 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:21.405361 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:22.405110 0.000000304 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:23.404945 0.000000304 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:24.405004 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:25.404869 0.000000304 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:26.405664 0.000000304 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:27.405452 0.000000304 0.000003384 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:41:28.405690 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:29.406257 0.000000302 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:30.406107 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:31.407176 0.000000304 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:32.406962 0.000000302 0.000003362 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:41:33.407750 0.000000302 0.000003384 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:41:34.407588 0.000000304 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:35.407461 0.000000306 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:36.407365 0.000000304 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:37.407206 0.000000302 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:38.407144 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:39.406973 0.000000304 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:40.406863 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:41.407851 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:42.408741 0.000000304 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:43.408455 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:44.408363 0.000000300 0.000003340 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:45.408507 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:46.409102 0.000000302 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:47.408996 0.000000304 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:48.409016 0.000000304 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:49.408903 0.000000304 0.000003384 0.000001516 BadVal BadVal BadVal BadVal
11/19/2013 10:41:50.408651 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:51.409561 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:52.409366 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:53.671050 0.000000302 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:54.675348 0.000000306 0.000003384 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:41:55.675949 0.000000300 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:56.676845 0.000000304 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:41:57.676692 0.000000300 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:58.676230 0.000000302 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:41:59.677764 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:00.677259 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:01.678167 0.000000304 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:02.679007 0.000000304 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:03.678882 0.000000304 0.000003384 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:42:04.679802 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:05.679736 0.000000300 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:06.680510 0.000000300 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:07.680434 0.000000302 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:08.680253 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:09.680303 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:10.680002 0.000000302 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:11.706336 0.000000304 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:12.706772 0.000000302 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:13.706749 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:14.707652 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:15.708502 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:16.709291 0.000000306 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:17.709139 0.000000304 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:18.709013 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:19.708875 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:20.708773 0.000000300 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:21.708676 0.000000300 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:22.708491 0.000000300 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:23.708396 0.000000304 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:24.708237 0.000000304 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:25.708129 0.000000304 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:26.709068 0.000000306 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:27.709892 0.000000304 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:28.709771 0.000000302 0.000003362 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:42:29.709605 0.000000302 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:30.709518 0.000000300 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:31.710437 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:32.710268 0.000000304 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:33.710139 0.000000304 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:34.710975 0.000000304 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:35.710972 0.000000308 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:36.711931 0.000000302 0.000003340 0.000001604 BadVal BadVal BadVal BadVal
11/19/2013 10:42:37.769372 0.000000304 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:38.769499 0.000000302 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:39.769426 0.000000304 0.000003384 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:42:40.768586 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:41.769111 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:42.769018 0.000000304 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:43.768903 0.000000302 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:44.768752 0.000000300 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:45.768651 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:46.769518 0.000000304 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:47.769367 0.000000304 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:48.769247 0.000000306 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:49.769168 0.000000306 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:50.769023 0.000000302 0.000003384 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:42:51.769882 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:52.769737 0.000000302 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:53.851442 0.000000304 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:54.851454 0.000000304 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:42:55.851327 0.000000304 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:56.852247 0.000000304 0.000003340 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:57.852146 0.000000302 0.000003340 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:58.851996 0.000000300 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:42:59.851955 0.000000300 0.000003362 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:43:00.851730 0.000000304 0.000003362 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:43:01.851594 0.000000304 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:43:02.851462 0.000000304 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:43:03.851516 0.000000300 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:43:04.851223 0.000000302 0.000003384 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:43:05.851091 0.000000300 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:43:06.850946 0.000000300 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:43:07.850844 0.000000304 0.000003384 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:43:08.851722 0.000000304 0.000003384 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:43:10.796013 0.000000304 0.000003384 0.000001538 BadVal BadVal BadVal BadVal
11/19/2013 10:43:11.796351 0.000000302 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:43:12.796332 0.000000302 0.000003362 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:43:13.796099 0.000000302 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:43:14.795971 0.000000302 0.000003384 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:43:15.795875 0.000000304 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:43:16.795690 0.000000304 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:43:17.795627 0.000000302 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:43:18.796444 0.000000302 0.000003362 0.000001560 BadVal BadVal BadVal BadVal
11/19/2013 10:43:19.796344 0.000000300 0.000003384 0.000001582 BadVal BadVal BadVal BadVal
11/19/2013 10:43:20.796217 0.000000300 0.000003384 0.000001560 26.32 BadVal BadVal BadVal
11/19/2013 10:43:21.797113 0.000000302 0.000003362 0.000001560 26.32 BadVal BadVal BadVal
11/19/2013 10:43:22.796966 0.000000304 0.000003362 0.000001560 26.32 BadVal BadVal BadVal
11/19/2013 10:43:23.796853 0.000000302 0.000003384 0.000001560 26.32 BadVal BadVal BadVal
11/19/2013 10:43:24.797719 0.000000304 0.000003384 0.000001560 25.17 0.48 BadVal BadVal
11/19/2013 10:43:25.797602 0.000000302 0.000003362 0.000001538 25.17 0.48 BadVal BadVal
11/19/2013 10:43:26.797843 0.000000302 0.000003384 0.000001538 25.17 0.48 BadVal BadVal
11/19/2013 10:43:27.797315 0.000000302 0.000003384 0.000001582 25.17 0.48 BadVal BadVal
11/19/2013 10:43:28.797410 0.000000304 0.000003362 0.000001560 25.17 0.48 BadVal BadVal
11/19/2013 10:43:29.797095 0.000000302 0.000003362 0.000001538 25.17 0.48 BadVal BadVal
11/19/2013 10:43:31.261550 0.000000304 0.000003384 0.000001560 26.32 0.48 BadVal BadVal
11/19/2013 10:43:32.261753 0.000000304 0.000003362 0.000001560 26.32 0.48 6.10 BadVal
11/19/2013 10:43:33.261681 0.000000304 0.000003362 0.000001582 26.32 0.48 6.10 BadVal
11/19/2013 10:43:34.261527 0.000000302 0.000003362 0.000001560 26.32 0.48 6.10 BadVal
11/19/2013 10:43:35.261401 0.000000302 0.000003384 0.000001560 25.17 0.48 6.10 BadVal
11/19/2013 10:43:36.261291 0.000000304 0.000003384 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:43:37.261143 0.000000304 0.000003384 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:43:38.357263 0.000000306 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:43:39.357863 0.000000306 0.000003384 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:43:40.357775 0.000000302 0.000003384 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:43:41.358683 0.000000302 0.000003384 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:43:42.358279 0.000000304 0.000003384 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:43:43.358382 0.000000304 0.000003384 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:43:44.358287 0.000000302 0.000003362 0.000001582 26.32 0.48 6.10 0.01
11/19/2013 10:43:45.358241 0.000000302 0.000003362 0.000001538 26.32 0.48 6.10 0.01
11/19/2013 10:43:46.359014 0.000000304 0.000003362 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:43:47.358900 0.000000302 0.000003362 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:43:48.553700 0.000000302 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:43:49.617444 0.000000302 0.000003362 0.000001538 25.17 0.48 6.10 0.01
11/19/2013 10:43:50.617485 0.000000304 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:43:51.617351 0.000000302 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:43:52.617213 0.000000302 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:43:53.618083 0.000000302 0.000003362 0.000001604 25.17 0.48 6.10 0.01
11/19/2013 10:43:54.693871 0.000000302 0.000003362 0.000001604 26.32 0.48 6.10 0.01
11/19/2013 10:43:55.693812 0.000000302 0.000003362 0.000001582 26.32 0.48 6.10 0.01
11/19/2013 10:43:56.693704 0.000000302 0.000003384 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:43:57.693643 0.000000304 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:43:58.693461 0.000000304 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:43:59.693350 0.000000302 0.000003384 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:00.693181 0.000000302 0.000003384 0.000001604 26.32 0.48 6.10 0.01
11/19/2013 10:44:01.694099 0.000000300 0.000003362 0.000001604 26.32 0.48 6.10 0.01
11/19/2013 10:44:02.694989 0.000000302 0.000003362 0.000001604 26.32 0.48 6.10 0.01
11/19/2013 10:44:03.694798 0.000000302 0.000003384 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:44:04.695712 0.000000304 0.000003384 0.000001582 26.32 0.48 6.10 0.01
11/19/2013 10:44:05.695611 0.000000306 0.000003362 0.000001538 26.32 0.48 6.10 0.01
11/19/2013 10:44:06.696507 0.000000304 0.000003384 0.000001582 26.32 0.48 6.10 0.01
11/19/2013 10:44:07.697388 0.000000306 0.000003362 0.000001538 26.32 0.48 6.10 0.01
11/19/2013 10:44:08.697233 0.000000300 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:09.697084 0.000000302 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:10.697082 0.000000302 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:11.697791 0.000000302 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:12.698710 0.000000304 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:13.698611 0.000000306 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:14.698625 0.000000302 0.000003384 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:15.698313 0.000000302 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:44:16.699228 0.000000304 0.000003384 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:17.699088 0.000000302 0.000003384 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:44:18.700241 0.000000302 0.000003362 0.000001582 26.32 0.48 6.10 0.01
11/19/2013 10:44:19.699985 0.000000304 0.000003362 0.000001516 26.32 0.48 6.10 0.01
11/19/2013 10:44:20.699919 0.000000302 0.000003362 0.000001582 26.32 0.48 6.10 0.01
11/19/2013 10:44:21.700749 0.000000304 0.000003362 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:44:22.700485 0.000000302 0.000003362 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:44:23.700313 0.000000302 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:24.700161 0.000000302 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:25.700124 0.000000302 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:44:26.826729 0.000000304 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:27.826774 0.000000304 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:44:28.826673 0.000000304 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:29.826713 0.000000302 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:30.826398 0.000000302 0.000003362 0.000001538 25.17 0.48 6.10 0.01
11/19/2013 10:44:31.826314 0.000000304 0.000003362 0.000001538 25.17 0.48 6.10 0.01
11/19/2013 10:44:32.826263 0.000000304 0.000003362 0.000001538 25.17 0.48 6.10 0.01
11/19/2013 10:44:33.826027 0.000000304 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:34.825896 0.000000304 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:35.825862 0.000000304 0.000003384 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:44:36.825771 0.000000300 0.000003384 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:37.826602 0.000000302 0.000003384 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:44:38.826434 0.000000300 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:39.826342 0.000000304 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:40.826153 0.000000304 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:44:41.826047 0.000000304 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:44:42.825889 0.000000304 0.000003384 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:43.825806 0.000000300 0.000003362 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:44:44.825678 0.000000302 0.000003362 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:44:45.825560 0.000000300 0.000003362 0.000001582 26.32 0.48 6.10 0.01
11/19/2013 10:44:46.825450 0.000000304 0.000003362 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:44:47.825323 0.000000302 0.000003362 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:44:48.825136 0.000000302 0.000003362 0.000001538 26.32 0.48 6.10 0.01
11/19/2013 10:44:49.825003 0.000000302 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:44:50.825965 0.000000304 0.000003384 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:44:51.825800 0.000000302 0.000003362 0.000001538 26.32 0.48 6.10 0.01
11/19/2013 10:44:52.825783 0.000000300 0.000003340 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:44:53.826612 0.000000304 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:44:54.826401 0.000000304 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:44:57.57542 0.000000304 0.000003362 0.000001582 26.32 0.48 6.10 0.01
11/19/2013 10:44:58.57013 0.000000306 0.000003362 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:44:59.56879 0.000000302 0.000003362 0.000001538 25.17 0.48 6.10 0.01
11/19/2013 10:45:00.146237 0.000000300 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:45:01.146631 0.000000302 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:45:02.146917 0.000000304 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:45:03.146342 0.000000304 0.000003384 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:45:04.146247 0.000000304 0.000003362 0.000001560 26.32 0.48 6.10 0.01
11/19/2013 10:45:05.146129 0.000000302 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:45:06.146037 0.000000300 0.000003362 0.000001560 25.17 0.48 6.10 0.01
11/19/2013 10:45:07.146918 0.000000302 0.000003362 0.000001538 26.32 0.48 6.10 0.01
11/19/2013 10:45:08.146753 0.000000304 0.000003384 0.000001582 26.32 0.48 6.10 0.01
11/19/2013 10:45:09.146640 0.000000302 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:45:10.146497 0.000000304 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:45:11.146466 0.000000304 0.000003362 0.000001582 25.17 0.48 6.10 0.01
11/19/2013 10:45:12.147338 0.000000300 0.000003362 0.000001582 4.57 0.85 6.10 0.01
11/19/2013 10:45:13.147084 0.000000300 0.000003384 0.000001560 4.57 0.85 6.10 0.01
11/19/2013 10:45:14.147016 0.000000302 0.000003362 0.000001582 12.58 0.85 6.10 0.01
11/19/2013 10:45:15.146891 0.000000304 0.000003362 0.000001538 12.58 0.61 6.10 0.01
11/19/2013 10:45:16.146881 0.000000304 0.000003362 0.000001560 16.02 0.42 6.10 0.01
11/19/2013 10:45:17.147759 0.000000302 0.000003362 0.000001560 16.02 0.42 6.10 0.01
11/19/2013 10:45:18.147575 0.000000302 0.000003384 0.000001560 3.43 0.42 6.10 0.01
11/19/2013 10:45:19.147328 0.000000302 0.000003362 0.000001560 3.43 0.42 6.10 0.01
11/19/2013 10:45:20.147232 0.000000300 0.000003384 0.000001582 11.44 0.42 6.10 0.01
11/19/2013 10:45:21.148144 0.000000302 0.000003384 0.000001560 14.87 0.48 6.10 0.01
11/19/2013 10:45:22.149018 0.000000304 0.000003362 0.000001560 18.31 0.48 6.10 0.01
11/19/2013 10:45:23.150194 0.000000306 0.000003384 0.000001560 18.31 0.48 6.10 0.01
11/19/2013 10:45:24.150804 0.000000302 0.000003362 0.000001582 21.74 0.48 6.10 0.01
11/19/2013 10:45:25.150602 0.000000300 0.000003362 0.000001582 21.74 0.48 6.10 0.01
11/19/2013 10:45:26.150449 0.000000300 0.000003384 0.000001538 21.74 0.48 6.10 0.01
11/19/2013 10:45:27.151409 0.000000304 0.000003384 0.000001560 21.74 0.48 6.10 0.01
11/19/2013 10:45:28.151267 0.000000304 0.000003362 0.000001560 22.88 0.48 6.10 0.01
11/19/2013 10:45:29.151108 0.000000302 0.000003362 0.000001582 22.88 0.48 6.10 0.01
11/19/2013 10:45:30.151084 0.000000300 0.000003362 0.000001560 24.03 0.24 6.10 0.01
11/19/2013 10:45:31.150818 0.000000300 0.000003362 0.000001538 11.44 0.24 6.10 0.01
11/19/2013 10:45:32.151726 0.000000302 0.000003362 0.000001538 510.41 2.92 7.32 0.01
11/19/2013 10:45:33.151733 0.000000302 0.000003362 0.000001538 511.55 0.12 7.32 0.01
11/19/2013 10:45:34.151441 0.000000302 0.000003362 0.000001560 1511.78 3.84 7.93 0.01
11/19/2013 10:45:35.151315 0.000000302 0.000003362 0.000001582 2011.90 2.86 9.15 0.01
11/19/2013 10:45:36.151190 0.000000302 0.000003362 0.000001560 3512.24 12.14 9.76 0.01
11/19/2013 10:45:37.151117 0.000000302 0.000003362 0.000001538 5517.28 11.16 9.76 0.01
11/19/2013 10:45:38.150938 0.000000302 0.000003362 0.000001560 7514.30 17.15 15.25 0.01
11/19/2013 10:45:39.150851 0.000000306 0.000003384 0.000001582 9015.79 12.32 15.25 0.01
11/19/2013 10:45:40.150756 0.000000302 0.000003384 0.000001582 11016.25 15.25 15.25 0.01
11/19/2013 10:45:41.150571 0.000000302 0.000003384 0.000001560 13016.70 17.94 15.25 0.01
11/19/2013 10:45:42.151464 0.000000304 0.000003362 0.000001560 14518.19 19.22 16.47 0.01
11/19/2013 10:45:43.151354 0.000000302 0.000003362 0.000001582 16522.08 22.33 16.47 0.01
11/19/2013 10:45:44.151303 0.000000302 0.000003384 0.000001582 18519.11 23.49 17.09 0.01
11/19/2013 10:45:45.151188 0.000000302 0.000003362 0.000001582 20585.94 28.56 17.09 0.01
11/19/2013 10:45:46.151036 0.000000302 0.000003362 0.000001582 22523.46 30.76 17.70 0.01
11/19/2013 10:45:47.152035 0.000000302 0.000003362 0.000001582 24521.62 28.44 17.70 0.01
11/19/2013 10:45:48.151742 0.000000302 0.000003384 0.000001582 26520.94 31.37 17.09 0.01
11/19/2013 10:45:49.151657 0.000000304 0.000003362 0.000001560 28524.83 31.73 17.70 0.01
11/19/2013 10:45:50.151484 0.000000306 0.000003362 0.000001582 30025.17 35.09 17.70 0.01
11/19/2013 10:45:51.151476 0.000000304 0.000003362 0.000001582 32027.92 40.10 17.70 0.01
11/19/2013 10:45:52.151329 0.000000302 0.000003384 0.000001560 34024.94 42.54 17.70 0.01
11/19/2013 10:45:53.151052 0.000000302 0.000003362 0.000001538 36027.69 38.87 17.70 0.01
11/19/2013 10:45:54.150967 0.000000304 0.000003362 0.000001560 37528.03 43.15 17.70 0.01
11/19/2013 10:45:55.150804 0.000000304 0.000003362 0.000001560 39026.09 43.09 17.09 0.01
11/19/2013 10:45:56.150672 0.000000304 0.000003384 0.000001560 40528.72 43.88 17.09 0.01
11/19/2013 10:45:57.151583 0.000000306 0.000003384 0.000001538 42027.92 45.96 15.25 0.01
11/19/2013 10:45:58.151490 0.000000302 0.000003362 0.000001560 43094.52 46.50 15.25 0.01
11/19/2013 10:45:59.151326 0.000000300 0.000003362 0.000001538 44528.49 48.64 31.12 0.01
11/19/2013 10:46:00.151211 0.000000302 0.000003362 0.000001560 45529.86 49.74 50.65 0.01
11/19/2013 10:46:01.151080 0.000000304 0.000003384 0.000001538 47031.35 51.33 68.36 0.01
11/19/2013 10:46:02.151382 0.000000304 0.000003384 0.000001538 48028.15 54.07 78.73 0.01
11/19/2013 10:46:03.151823 0.000000304 0.000003384 0.000001582 49029.52 54.44 76.90 0.01
... 2782 more lines ...
|
553
|
Wednesday, November 20, 2013, 13:52 |
Bevan Moss | Conditioning Station | Standard Operation | TM2 | | HV testing of TM2 |
HV testing without the cover continued today. With the EINZEL lens at 30kV the target module was able to achieve 58.7kV. At this voltage any spark was reeking havoc on the electronics of the TCS. Vacuum gauges signals were occasionally lost, the thermocouple reading would occasionally be lost, turbo pump would turn off. All of these events caused the interlocks to trip resulting in the power supplies to be turned off. As a result I bypassed majority of the interlocks to prevent this from happening. Ultimately as spark took out the CANBUS controller first for the EINZEL lens and then for the BIAS. David Morris has been contacted to have them replaced. The damage of the CANBUS controller for these power supplies is becoming a common problem and should be investigated for if there is a better solution. During testing I experimented with raising the BIAS to near its limit followed by the EINZEL lens and vise versa. From this it was determined that the EINZEL must be raised to high voltage before the BIAS otherwise sparking occurs. Even a step from 0 to 500 volts on the ENIZEL lens with the BIAS at 55kV caused sparking. There are a few combinations of testing along this line I would like to continue with but initially my though is that the BIAS and ENIZEL do not have sufficient clearance for the BIAS to operate above 55kV. Attached is a screen shot of the strip tool and the data. I have not heard from David yet but I do not expect the TCS to be operational today. |
Attachment 1: 20112013_HV_conditioning_TM2.JPG
|
|
Attachment 2: 20112013_TM2_No_source_tray_HV_Test_no_cover.txt
|
Time TCS:IG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:BIAS:RDVOL [V] TCS:BIAS:RDCUR [uA] TCS:EL:RDVOL [V] TCS:EL:RDCUR [mA]
11/20/2013 10:34:48.414676 0.000000253 0.000003120 BadVal BadVal BadVal BadVal BadVal
11/20/2013 10:34:49.413724 0.000000253 0.000003098 BadVal BadVal BadVal BadVal BadVal
11/20/2013 10:34:50.414780 0.000000256 0.000003120 BadVal BadVal BadVal BadVal BadVal
11/20/2013 10:34:51.414583 0.000000258 0.000003120 BadVal BadVal BadVal BadVal BadVal
11/20/2013 10:34:52.414423 0.000000260 0.000003120 BadVal BadVal BadVal BadVal BadVal
11/20/2013 10:34:53.415237 0.000000258 0.000003120 BadVal BadVal BadVal BadVal BadVal
11/20/2013 10:34:54.416059 0.000000258 0.000003098 BadVal BadVal BadVal BadVal BadVal
11/20/2013 10:34:55.506062 0.000000258 0.000003098 BadVal BadVal BadVal BadVal BadVal
11/20/2013 10:34:56.506814 0.000000258 0.000003120 0.000001230 BadVal BadVal BadVal BadVal
11/20/2013 10:34:57.506697 0.000000256 0.000003098 0.000001230 BadVal BadVal BadVal BadVal
11/20/2013 10:34:58.506780 0.000000258 0.000003120 0.000001230 BadVal BadVal BadVal BadVal
11/20/2013 10:34:59.506511 0.000000260 0.000003120 0.000001252 BadVal BadVal BadVal BadVal
11/20/2013 10:35:00.507321 0.000000258 0.000003120 0.000001230 BadVal BadVal BadVal BadVal
11/20/2013 10:35:01.507271 0.000000258 0.000003120 0.000001230 BadVal BadVal BadVal BadVal
11/20/2013 10:35:02.507196 0.000000256 0.000003098 0.000001230 BadVal BadVal BadVal BadVal
11/20/2013 10:35:03.507937 0.000000256 0.000003098 0.000001230 BadVal BadVal BadVal BadVal
11/20/2013 10:35:04.508830 0.000000256 0.000003098 0.000001230 BadVal BadVal BadVal BadVal
11/20/2013 10:35:05.509815 0.000000253 0.000003120 0.000001230 BadVal BadVal BadVal BadVal
11/20/2013 10:35:06.510560 0.000000258 0.000003120 0.000001208 BadVal BadVal BadVal BadVal
11/20/2013 10:35:07.511442 0.000000260 0.000003120 0.000001208 BadVal BadVal BadVal BadVal
11/20/2013 10:35:08.511382 0.000000258 0.000003098 0.000001208 27.46 BadVal BadVal BadVal
11/20/2013 10:35:09.511380 0.000000260 0.000003120 0.000001252 26.32 BadVal BadVal BadVal
11/20/2013 10:35:10.511063 0.000000258 0.000003120 0.000001252 26.32 BadVal BadVal BadVal
11/20/2013 10:35:11.510938 0.000000256 0.000003098 0.000001252 27.46 BadVal BadVal BadVal
11/20/2013 10:35:12.510832 0.000000256 0.000003120 0.000001208 27.46 BadVal BadVal BadVal
11/20/2013 10:35:13.510688 0.000000258 0.000003120 0.000001208 27.46 0.42 BadVal BadVal
11/20/2013 10:35:14.510527 0.000000258 0.000003098 0.000001230 27.46 0.42 BadVal BadVal
11/20/2013 10:35:15.510410 0.000000258 0.000003120 0.000001230 27.46 0.42 BadVal BadVal
11/20/2013 10:35:16.510321 0.000000256 0.000003098 0.000001230 27.46 0.42 BadVal BadVal
11/20/2013 10:35:17.510214 0.000000256 0.000003098 0.000001230 26.32 0.42 BadVal BadVal
11/20/2013 10:35:18.510025 0.000000256 0.000003120 0.000001230 26.32 0.42 5.49 BadVal
11/20/2013 10:35:19.509934 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 BadVal
11/20/2013 10:35:20.509860 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 BadVal
11/20/2013 10:35:21.511728 0.000000258 0.000003120 0.000001230 27.46 0.42 5.49 BadVal
11/20/2013 10:35:22.511632 0.000000260 0.000003120 0.000001230 27.46 0.42 5.49 BadVal
11/20/2013 10:35:23.511584 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:24.591659 0.000000258 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:25.729112 0.000000253 0.000003098 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:35:26.729088 0.000000258 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:35:27.729906 0.000000253 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:35:28.729930 0.000000260 0.000003120 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:35:29.729660 0.000000258 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:35:30.729489 0.000000258 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:35:31.729372 0.000000258 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:35:32.730305 0.000000253 0.000003098 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:35:33.853965 0.000000256 0.000003120 0.000001252 26.32 0.42 5.49 0.01
11/20/2013 10:35:34.854006 0.000000258 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:35.949159 0.000000258 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:36.949749 0.000000256 0.000003098 0.000001252 27.46 0.42 5.49 0.01
11/20/2013 10:35:37.949644 0.000000256 0.000003120 0.000001252 27.46 0.42 5.49 0.01
11/20/2013 10:35:38.949535 0.000000256 0.000003120 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:35:39.950466 0.000000256 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:35:41.28198 0.000000256 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:42.34724 0.000000256 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:43.34971 0.000000256 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:44.34865 0.000000260 0.000003098 0.000001252 27.46 0.42 5.49 0.01
11/20/2013 10:35:45.34739 0.000000258 0.000003120 0.000001252 26.32 0.42 5.49 0.01
11/20/2013 10:35:46.34576 0.000000258 0.000003098 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:35:47.34484 0.000000256 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:35:48.35380 0.000000258 0.000003120 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:35:49.35302 0.000000256 0.000003120 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:35:50.36136 0.000000253 0.000003120 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:35:51.35938 0.000000253 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:35:52.35873 0.000000260 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:35:53.35802 0.000000260 0.000003098 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:35:54.35700 0.000000260 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:55.35442 0.000000260 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:56.35354 0.000000256 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:35:57.35238 0.000000258 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:58.36111 0.000000253 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:35:59.35984 0.000000260 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:00.35832 0.000000260 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:01.35689 0.000000260 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:02.144399 0.000000256 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:03.144478 0.000000258 0.000003098 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:04.144502 0.000000256 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:05.145332 0.000000258 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:06.145089 0.000000253 0.000003098 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:07.145209 0.000000260 0.000003098 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:08.145838 0.000000260 0.000003120 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:36:09.146802 0.000000260 0.000003098 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:36:10.146584 0.000000258 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:11.146460 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:12.146294 0.000000256 0.000003098 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:13.146305 0.000000258 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:14.146042 0.000000258 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:15.145915 0.000000258 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:16.145794 0.000000258 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:17.145705 0.000000256 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:18.145906 0.000000258 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:19.145434 0.000000258 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:20.145323 0.000000253 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:21.145202 0.000000256 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:22.145076 0.000000260 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:23.146118 0.000000260 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:24.145825 0.000000258 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:25.155723 0.000000258 0.000003120 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:36:26.155570 0.000000258 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:27.155437 0.000000256 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:28.155279 0.000000256 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:29.155155 0.000000256 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:30.155132 0.000000256 0.000003098 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:31.155083 0.000000258 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:32.154768 0.000000258 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:33.154675 0.000000258 0.000003098 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:34.154594 0.000000253 0.000003120 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:36:35.155716 0.000000256 0.000003120 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:36:36.156306 0.000000258 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:37.156322 0.000000256 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:38.156054 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:39.155899 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:40.313843 0.000000258 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:41.313756 0.000000253 0.000003120 0.000001208 26.32 0.42 5.49 0.01
11/20/2013 10:36:42.313502 0.000000253 0.000003098 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:43.313407 0.000000256 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:44.313288 0.000000258 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:45.313123 0.000000258 0.000003098 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:46.313028 0.000000256 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:47.312863 0.000000256 0.000003098 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:48.313869 0.000000258 0.000003120 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:49.314706 0.000000256 0.000003098 0.000001230 26.32 0.42 5.49 0.01
11/20/2013 10:36:50.315547 0.000000253 0.000003120 0.000001186 26.32 0.42 5.49 0.01
11/20/2013 10:36:51.315404 0.000000260 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:52.315285 0.000000256 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:53.316161 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:54.316185 0.000000260 0.000003098 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:55.317074 0.000000256 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:56.316803 0.000000258 0.000003120 0.000001208 27.46 0.42 5.49 0.01
11/20/2013 10:36:57.316655 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:58.316082 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:36:59.316373 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:37:00.316469 0.000000256 0.000003120 0.000001230 27.46 0.42 5.49 0.01
11/20/2013 10:37:01.316114 0.000000256 0.000003120 0.000001230 27.46 0.42 0.61 0.01
11/20/2013 10:37:02.316025 0.000000260 0.000003098 0.000001230 26.32 0.42 0.61 0.01
11/20/2013 10:37:03.316970 0.000000260 0.000003120 0.000001230 8.01 0.42 0.61 0.01
11/20/2013 10:37:04.316771 0.000000256 0.000003120 0.000001230 8.01 0.42 0.61 0.01
11/20/2013 10:37:05.316651 0.000000253 0.000003098 0.000001230 9.15 0.79 4.27 0.01
11/20/2013 10:37:06.316545 0.000000256 0.000003098 0.000001230 9.15 0.79 4.27 0.01
11/20/2013 10:37:07.316358 0.000000256 0.000003120 0.000001230 12.58 0.79 6.10 0.01
11/20/2013 10:37:08.317387 0.000000256 0.000003120 0.000001208 12.58 0.79 5.49 0.01
11/20/2013 10:37:09.318100 0.000000256 0.000003076 0.000001208 10.29 0.91 5.49 0.01
11/20/2013 10:37:10.317973 0.000000256 0.000003098 0.000001230 12.58 0.73 5.49 0.01
11/20/2013 10:37:11.317854 0.000000256 0.000003120 0.000001208 12098.87 6.77 30.51 0.01
11/20/2013 10:37:12.317785 0.000000253 0.000003120 0.000001208 9037.53 5.37 8.54 0.01
11/20/2013 10:37:13.318646 0.000000256 0.000003120 0.000001208 6778.43 4.08 8.54 0.01
11/20/2013 10:37:14.318517 0.000000258 0.000003120 0.000001208 5105.28 3.41 3.05 0.01
11/20/2013 10:37:15.318456 0.000000258 0.000003120 0.000001208 3855.57 2.86 3.05 0.01
11/20/2013 10:37:16.319259 0.000000256 0.000003120 0.000001230 2921.72 1.95 0.61 0.01
11/20/2013 10:37:17.319100 0.000000256 0.000003120 0.000001208 2237.35 1.58 0.61 0.01
11/20/2013 10:37:18.320004 0.000000253 0.000003120 0.000001230 1826.50 1.15 1.83 0.01
11/20/2013 10:37:19.320985 0.000000256 0.000003120 0.000001208 1478.59 1.15 1.83 0.01
11/20/2013 10:37:20.320764 0.000000258 0.000003120 0.000001208 1197.07 1.03 3.66 0.01
11/20/2013 10:37:21.320666 0.000000253 0.000003120 0.000001230 969.32 1.03 3.66 0.01
11/20/2013 10:37:22.321547 0.000000258 0.000003120 0.000001230 785.07 1.03 4.27 0.01
11/20/2013 10:37:23.322366 0.000000258 0.000003120 0.000001230 635.15 1.03 4.27 0.01
11/20/2013 10:37:24.322396 0.000000258 0.000003120 0.000001230 513.84 0.91 4.27 0.01
11/20/2013 10:37:25.322137 0.000000256 0.000003120 0.000001230 415.42 0.91 4.27 0.01
11/20/2013 10:37:26.321987 0.000000256 0.000003142 0.000001230 335.31 0.91 4.88 0.01
11/20/2013 10:37:27.321928 0.000000253 0.000003120 0.000001208 270.08 0.91 4.88 0.01
11/20/2013 10:37:28.322956 0.000000256 0.000003098 0.000001230 216.29 0.91 4.88 0.01
11/20/2013 10:37:29.323592 0.000000256 0.000003098 0.000001230 179.67 0.91 4.88 0.01
11/20/2013 10:37:30.323486 0.000000256 0.000003142 0.000001230 141.90 0.91 4.88 0.01
11/20/2013 10:37:31.323450 0.000000258 0.000003120 0.000001230 108.72 0.91 4.88 0.01
11/20/2013 10:37:32.323271 0.000000258 0.000003120 0.000001208 89.26 0.91 4.88 0.01
11/20/2013 10:37:33.324362 0.000000258 0.000003098 0.000001208 70.95 0.91 4.88 0.01
11/20/2013 10:37:34.324005 0.000000256 0.000003120 0.000001208 53.78 0.91 5.49 0.01
11/20/2013 10:37:35.323838 0.000000256 0.000003120 0.000001208 53.78 0.91 1.83 0.01
11/20/2013 10:37:36.324765 0.000000258 0.000003120 0.000001230 33.18 0.91 1.83 0.01
11/20/2013 10:37:37.324726 0.000000258 0.000003120 0.000001230 17.16 0.91 1.22 0.01
11/20/2013 10:37:38.325505 0.000000258 0.000003120 0.000001186 17.16 0.91 1.22 0.01
11/20/2013 10:37:39.325336 0.000000258 0.000003098 0.000001208 4.57 0.36 1.22 0.01
11/20/2013 10:37:40.325348 0.000000260 0.000003120 0.000001230 4.57 0.36 1.22 0.01
11/20/2013 10:37:41.325141 0.000000258 0.000003120 0.000001230 12.58 0.79 1.22 0.01
11/20/2013 10:37:42.325021 0.000000256 0.000003120 0.000001230 12.58 0.79 1.22 0.01
11/20/2013 10:37:43.325865 0.000000253 0.000003120 0.000001230 9.15 0.91 0.61 0.01
11/20/2013 10:37:44.325763 0.000000258 0.000003120 0.000001230 9.15 0.91 0.61 0.01
11/20/2013 10:37:45.325605 0.000000258 0.000003098 0.000001230 10.29 0.91 0.61 0.01
11/20/2013 10:37:46.325508 0.000000253 0.000003120 0.000001230 10.29 0.91 0.61 0.01
11/20/2013 10:37:47.325388 0.000000256 0.000003098 0.000001230 5.72 0.91 998.55 0.04
11/20/2013 10:37:48.326442 0.000000258 0.000003120 0.000001230 5.72 0.91 3000.53 0.09
11/20/2013 10:37:49.326181 0.000000256 0.000003098 0.000001252 8.01 0.91 4500.80 0.23
11/20/2013 10:37:50.325945 0.000000256 0.000003120 0.000001230 8.01 0.91 5001.90 0.23
11/20/2013 10:37:51.326819 0.000000256 0.000003120 0.000001230 5.72 0.91 5568.93 0.23
11/20/2013 10:37:52.326754 0.000000256 0.000003120 0.000001230 5.72 0.91 7003.28 0.23
11/20/2013 10:37:53.327593 0.000000256 0.000003142 0.000001230 5.72 0.91 8003.66 0.23
11/20/2013 10:37:54.327448 0.000000256 0.000003120 0.000001208 13.73 0.91 9502.70 0.53
11/20/2013 10:37:55.328351 0.000000260 0.000003120 0.000001230 13.73 0.91 10506.14 0.35
11/20/2013 10:37:56.328292 0.000000258 0.000003120 0.000001208 17.16 0.91 11781.79 0.38
11/20/2013 10:37:57.328116 0.000000256 0.000003120 0.000001208 17.16 0.91 13006.17 0.44
11/20/2013 10:37:58.328287 0.000000256 0.000003120 0.000001208 9.15 0.91 14505.83 0.44
11/20/2013 10:37:59.328830 0.000000256 0.000003120 0.000001208 8.01 0.91 16503.54 0.58
11/20/2013 10:38:00.328696 0.000000256 0.000003120 0.000001230 8.01 0.91 18006.86 0.58
11/20/2013 10:38:01.328586 0.000000256 0.000003098 0.000001230 12.58 0.91 19506.52 0.69
11/20/2013 10:38:02.329506 0.000000258 0.000003098 0.000001208 12.58 0.91 21007.40 0.79
11/20/2013 10:38:03.330336 0.000000258 0.000003120 0.000001208 12.58 0.91 22507.66 0.79
11/20/2013 10:38:04.330331 0.000000258 0.000003098 0.000001208 4.57 0.91 23011.21 0.80
11/20/2013 10:38:05.330125 0.000000256 0.000003120 0.000001208 4.57 0.91 24009.15 0.81
11/20/2013 10:38:06.329942 0.000000256 0.000003120 0.000001208 12.58 0.79 25008.31 0.81
11/20/2013 10:38:07.329857 0.000000258 0.000003098 0.000001208 12.58 0.79 25010.14 0.81
11/20/2013 10:38:08.330714 0.000000258 0.000003098 0.000001208 5.72 0.91 25010.14 0.81
11/20/2013 10:38:09.330602 0.000000260 0.000003098 0.000001230 5.72 0.91 25011.97 0.81
11/20/2013 10:38:10.330506 0.000000253 0.000003098 0.000001230 5.72 0.73 25011.97 0.81
11/20/2013 10:38:11.331338 0.000000258 0.000003098 0.000001230 5.72 0.73 25011.97 0.81
11/20/2013 10:38:12.331188 0.000000258 0.000003120 0.000001252 6.86 0.73 25011.97 0.81
11/20/2013 10:38:13.332192 0.000000258 0.000003120 0.000001252 6.86 0.73 25011.97 0.81
11/20/2013 10:38:14.331985 0.000000256 0.000003120 0.000001252 10.29 0.85 25011.97 0.81
11/20/2013 10:38:15.331812 0.000000256 0.000003120 0.000001208 10.29 0.85 25012.58 0.81
11/20/2013 10:38:16.331676 0.000000256 0.000003120 0.000001208 13.73 0.85 25012.58 0.81
11/20/2013 10:38:17.331599 0.000000258 0.000003120 0.000001208 13.73 0.85 25012.58 0.81
11/20/2013 10:38:18.331562 0.000000260 0.000003098 0.000001208 10.29 0.85 25012.58 0.81
11/20/2013 10:38:19.331349 0.000000256 0.000003120 0.000001230 10.29 0.85 25012.58 0.81
11/20/2013 10:38:20.331173 0.000000256 0.000003120 0.000001230 8.01 0.85 25012.58 0.81
11/20/2013 10:38:21.331084 0.000000258 0.000003120 0.000001230 10.29 0.85 25012.58 0.81
11/20/2013 10:38:22.331021 0.000000256 0.000003120 0.000001230 10.29 0.85 25012.58 0.81
11/20/2013 10:38:23.330936 0.000000256 0.000003120 0.000001230 9.15 0.85 25012.58 0.81
11/20/2013 10:38:24.330710 0.000000260 0.000003120 0.000001230 9.15 0.85 25012.58 0.81
11/20/2013 10:38:25.330593 0.000000256 0.000003120 0.000001208 8.01 0.73 25012.58 0.81
11/20/2013 10:38:26.330462 0.000000258 0.000003120 0.000001208 8.01 0.73 25012.58 0.81
11/20/2013 10:38:27.330338 0.000000256 0.000003120 0.000001208 10.29 0.91 25012.58 0.81
11/20/2013 10:38:28.331226 0.000000253 0.000003120 0.000001230 10.29 0.91 25012.58 0.81
11/20/2013 10:38:29.331092 0.000000258 0.000003120 0.000001230 13.73 0.91 25012.58 0.81
11/20/2013 10:38:30.331004 0.000000258 0.000003098 0.000001230 13.73 0.91 25012.58 0.81
11/20/2013 10:38:31.330795 0.000000258 0.000003098 0.000001208 6.86 0.91 25012.58 0.81
11/20/2013 10:38:32.330772 0.000000260 0.000003120 0.000001208 6.86 0.91 25012.58 0.81
11/20/2013 10:38:33.331565 0.000000260 0.000003098 0.000001208 9.15 0.79 25012.58 0.81
11/20/2013 10:38:34.331463 0.000000258 0.000003098 0.000001230 9.15 0.79 25012.58 0.81
11/20/2013 10:38:35.331347 0.000000256 0.000003120 0.000001208 14.87 0.61 25012.58 0.81
11/20/2013 10:38:36.331211 0.000000258 0.000003120 0.000001208 14.87 0.61 25012.58 0.81
11/20/2013 10:38:37.331045 0.000000258 0.000003098 0.000001230 13.73 0.85 25012.58 0.81
11/20/2013 10:38:38.330950 0.000000256 0.000003098 0.000001230 13.73 0.85 25012.58 0.81
11/20/2013 10:38:39.330833 0.000000258 0.000003120 0.000001186 6.86 0.73 25012.58 0.81
11/20/2013 10:38:40.330708 0.000000256 0.000003120 0.000001208 6.86 0.73 25012.58 0.81
11/20/2013 10:38:41.330581 0.000000258 0.000003098 0.000001230 9.15 0.85 25012.58 0.81
11/20/2013 10:38:42.330469 0.000000253 0.000003098 0.000001186 6.86 0.73 25012.58 0.81
11/20/2013 10:38:43.331408 0.000000256 0.000003120 0.000001230 6.86 0.85 25012.58 0.81
11/20/2013 10:38:44.331413 0.000000256 0.000003120 0.000001230 1010.52 2.99 25012.58 0.81
11/20/2013 10:38:45.332046 0.000000256 0.000003120 0.000001208 1791.02 5.61 25012.58 0.81
11/20/2013 10:38:46.331944 0.000000258 0.000003098 0.000001230 2512.01 3.90 25012.58 0.81
11/20/2013 10:38:47.331830 0.000000258 0.000003120 0.000001208 3010.98 9.94 25012.58 0.81
11/20/2013 10:38:48.332698 0.000000256 0.000003120 0.000001230 4012.35 4.51 25012.58 0.81
11/20/2013 10:38:49.332575 0.000000258 0.000003120 0.000001230 5012.58 7.75 25012.58 0.81
11/20/2013 10:38:50.332461 0.000000253 0.000003098 0.000001230 6013.96 6.65 25012.58 0.81
11/20/2013 10:38:51.332339 0.000000256 0.000003098 0.000001230 7017.62 11.41 25012.58 0.81
11/20/2013 10:38:52.332236 0.000000256 0.000003098 0.000001230 8514.53 10.43 25012.58 0.81
11/20/2013 10:38:53.333086 0.000000256 0.000003098 0.000001230 9515.90 17.09 25012.58 0.81
11/20/2013 10:38:54.332965 0.000000256 0.000003098 0.000001230 11016.25 14.95 25012.58 0.81
11/20/2013 10:38:55.332817 0.000000256 0.000003120 0.000001230 12019.91 16.35 25012.58 0.81
11/20/2013 10:38:56.332686 0.000000253 0.000003098 0.000001186 13292.51 16.41 25012.58 0.81
11/20/2013 10:38:57.332571 0.000000256 0.000003120 0.000001186 14518.19 15.93 25012.58 0.81
11/20/2013 10:38:58.333428 0.000000256 0.000003120 0.000001230 15519.56 15.68 25012.58 0.81
11/20/2013 10:38:59.333281 0.000000256 0.000003120 0.000001230 16520.94 16.11 25012.58 0.81
11/20/2013 10:39:00.333153 0.000000256 0.000003098 0.000001208 18018.99 24.23 25012.58 0.81
11/20/2013 10:39:01.333093 0.000000253 0.000003142 0.000001208 19022.65 22.70 25012.58 0.81
11/20/2013 10:39:02.333017 0.000000260 0.000003120 0.000001230 20521.85 21.30 25012.58 0.81
11/20/2013 10:39:03.333874 0.000000256 0.000003098 0.000001230 22022.20 23.25 25012.58 0.81
11/20/2013 10:39:04.333737 0.000000258 0.000003098 0.000001208 23469.90 26.06 25012.58 0.81
11/20/2013 10:39:05.333680 0.000000256 0.000003120 0.000001230 24522.77 24.71 25012.58 0.81
11/20/2013 10:39:06.333393 0.000000256 0.000003120 0.000001230 26023.11 28.99 25012.58 0.81
11/20/2013 10:39:07.333417 0.000000258 0.000003120 0.000001208 27523.46 29.35 25012.58 0.81
11/20/2013 10:39:08.334148 0.000000258 0.000003120 0.000001230 29026.09 31.31 25012.58 0.81
11/20/2013 10:39:09.334056 0.000000256 0.000003120 0.000001230 30523.00 32.53 25012.58 0.81
11/20/2013 10:39:10.333927 0.000000253 0.000003120 0.000001230 31525.52 31.67 25012.58 0.81
11/20/2013 10:39:11.333973 0.000000256 0.000003120 0.000001230 32528.03 30.15 25012.58 0.81
11/20/2013 10:39:12.334739 0.000000256 0.000003120 0.000001230 33801.78 36.19 25012.58 0.81
11/20/2013 10:39:13.335695 0.000000253 0.000003120 0.000001230 35026.32 35.33 25012.58 0.81
11/20/2013 10:39:14.335425 0.000000253 0.000003120 0.000001230 36474.02 39.06 25012.58 0.81
11/20/2013 10:39:15.336686 0.000000253 0.000003098 0.000001230 37526.89 38.20 25012.58 0.81
11/20/2013 10:39:16.337275 0.000000258 0.000003098 0.000001230 38527.12 38.20 25012.58 0.81
11/20/2013 10:39:17.338221 0.000000253 0.000003098 0.000001208 39974.82 39.61 25012.58 0.81
11/20/2013 10:39:18.338918 0.000000253 0.000003098 0.000001186 41027.69 41.44 25012.58 0.81
11/20/2013 10:39:19.338838 0.000000256 0.000003098 0.000001230 42029.06 41.74 25012.58 0.81
11/20/2013 10:39:20.338621 0.000000256 0.000003098 0.000001208 43028.15 49.80 25012.58 0.81
11/20/2013 10:39:21.338512 0.000000256 0.000003098 0.000001208 44526.20 53.40 25012.58 0.81
11/20/2013 10:39:22.338428 0.000000258 0.000003098 0.000001230 45528.72 48.34 25012.58 0.81
11/20/2013 10:39:23.339288 0.000000258 0.000003098 0.000001186 46528.95 48.46 25012.58 0.81
11/20/2013 10:39:24.339252 0.000000253 0.000003098 0.000001230 47529.18 52.36 25012.58 0.81
11/20/2013 10:39:25.339125 0.000000256 0.000003098 0.000001230 48975.73 52.67 25012.58 0.81
11/20/2013 10:39:26.338885 0.000000256 0.000003120 0.000001208 50026.32 52.85 25012.58 0.81
11/20/2013 10:39:27.338831 0.000000256 0.000003098 0.000001208 51027.69 55.35 25012.58 0.81
11/20/2013 10:39:28.339727 0.000000258 0.000003120 0.000001230 52025.63 56.09 25012.58 0.81
11/20/2013 10:39:29.339894 0.000000256 0.000003120 0.000001230 53027.00 56.45 25012.58 0.81
11/20/2013 10:39:30.340396 0.000000256 0.000003120 0.000001230 54030.67 62.74 25012.58 0.81
11/20/2013 10:39:31.340369 0.000000260 0.000003120 0.000001230 54594.87 66.28 25012.58 0.81
11/20/2013 10:39:32.340350 0.000000253 0.000003120 0.000001230 55528.72 64.69 25012.58 0.81
11/20/2013 10:39:33.341106 0.000000260 0.000003120 0.000001230 56029.98 69.58 25012.58 0.81
11/20/2013 10:39:34.340924 0.000000260 0.000003098 0.000001252 56031.12 69.09 25012.58 0.81
11/20/2013 10:39:35.340837 0.000000319 0.000003758 0.000001604 56032.27 68.90 25012.58 0.81
11/20/2013 10:39:36.340732 0.000000306 0.000003714 0.000001626 56032.27 70.61 25012.58 0.81
11/20/2013 10:39:37.341651 0.000000300 0.000003582 0.000001604 56032.27 69.88 25012.58 0.81
11/20/2013 10:39:38.342419 0.000000291 0.000003538 0.000001560 56032.27 67.68 25012.58 0.81
11/20/2013 10:39:39.342271 0.000000291 0.000003494 0.000001560 56032.27 68.54 25012.58 0.81
11/20/2013 10:39:40.342168 0.000000289 0.000003494 0.000001560 56032.27 68.17 25012.58 0.81
11/20/2013 10:39:41.341996 0.000000289 0.000003472 0.000001494 56032.27 66.77 25012.58 0.81
11/20/2013 10:39:42.341916 0.000000284 0.000003450 0.000001494 56032.27 67.99 25012.58 0.81
11/20/2013 10:39:43.342793 0.000000284 0.000003450 0.000001472 56032.27 66.10 25012.58 0.81
11/20/2013 10:39:44.342661 0.000000282 0.000003384 0.000001450 56032.27 67.01 25012.58 0.81
11/20/2013 10:39:45.342577 0.000000282 0.000003384 0.000001450 56032.27 67.32 25012.58 0.81
11/20/2013 10:39:46.343125 0.000000282 0.000003362 0.000001450 56032.27 67.13 25012.58 0.81
11/20/2013 10:39:47.343318 0.000000282 0.000003384 0.000001450 56032.27 65.24 25012.58 0.81
... 10427 more lines ...
|
557
|
Tuesday, November 26, 2013, 14:10 |
Travis Cave | Crane | Maintenance | | | Thermal relay replaced |
The bad thermal motor protection relay for the crane has been replaced with a new unit. Crane was tested in pendant(local) operation and all drives worked. |
558
|
Wednesday, November 27, 2013, 12:50 |
Bevan Moss | South Hot-Cell | Standard Operation | TM3 | | Ground devices wiring check |
Travis and I completed an electrical check on the wiring harness for the devices on the ground plane. All lines passed 500V with the megger except for PNG and the BTM steerer. Those devices had a short to ground. of ~1.4ohm. |
559
|
Wednesday, November 27, 2013, 15:24 |
Bevan Moss | South Hot-Cell | Maintenance | TM3 | | Wiring Harness Electrical Test |
Maico removed the containment box today allow Travis and I to further test the wiring harness. I disconnected the junction block and Travis and I repeated the test from yesterday. The all lines except the PNG tested OL. The module was then lowered and the twisted pair connected to the pin that corresponds to the steerer labeled BTM (it is likely this is not labeled correctly). This testing showed showed that the source of the short found yesterday is in the wiring harness or the source tray. The PNG gauge was then tested again. When beeping out the harness to find the location of the pin it was found that the short had gone away. This circuit was then tested with the megger at 500V and showed OL. Don Jackson has suggested looking at the SHV feed through. It is difficult to determine where the source of the problem is as it is intermittent. The source tray side wiring harness for the steerers was then disconnected from the steerers and tested to OL. Finally the connections on the source tray were tested. It was determined that the third socket down (see attached picture) has a short somewhere to ground. When Chad returns on Friday I will have him complete a visual inspection and if the source can be found we may be able to deflect the line. Failing that to repair this connection a new steerer cone assembly will need to be installed. |
Attachment 1: IMG_1269.JPG
|
|
560
|
Friday, November 29, 2013, 11:54 |
chad fisher | South Hot-Cell | Repair | TM3 | | Steerer short investegation |
Using in cell camera and transit the suspect line on the steerers was inspected as best as possible. An existing photo of the complete steerers before installation was used for comparison. The wiring and beading inspected today showed no obvious problems, breaks or spots where there may be a short. In comparison to the photo from construction, what we could see of the steerers looked identical to the original installation. |
Attachment 1: TM3_20131129_Steerer_1.jpg
|
|
Attachment 2: TM3_20131129_Steerer_2.jpg
|
|
Attachment 3: TM3_20131129_Steerer_3.jpg
|
|
561
|
Friday, November 29, 2013, 11:57 |
Bevan Moss | South Hot-Cell | Repair | TM3 | | Steerer short investegation |
chad fisher wrote: |
Using in cell camera and transit the suspect line on the steerers was inspected as best as possible. An existing photo of the complete steerers before installation was used for comparison. The wiring and beading inspected today showed no obvious problems, breaks or spots where there may be a short. In comparison to the photo from construction, what we could see of the steerers looked identical to the original installation.
|
The test was repeated to confirm that there was a short. |
563
|
Tuesday, December 03, 2013, 09:58 |
David Wang | ITW | Standard Operation | TM4 | | I moved 5 shielding blocks from ITW to block storage area. |
I moved 5 shielding blocks from ITW to block storage area. |
564
|
Tuesday, December 03, 2013, 10:35 |
Travis Cave | ITW | Standard Operation | | | fields above and in the target station with blocks off |
The blocks have been removed from the west target station. The fields at the top of the target pit at the railing at waist level is about 80uSv/hr, Turbo pumps are about 805uSv/hr, backing lines for the turbos about a 1mSv/hr and the average field in the area of work down in the pit is about 600 to 750uSv/hr. The proton beam went off at 10:45 on December 2nd, these measurements were done at 09:00 on December 3rd.
Another set of field measurement was done at the west target station. At the top of the west target station at the railing the field ranged from 50 to 70 uSv/hr. The turbo pumps had field of about 650uSv/hr, the area over the dump was about 750uSv/hr, the area over the HV cover and the south side was about 450uSv/hr. These measurements were done at 13:15 on December 3rd. |
565
|
Tuesday, December 03, 2013, 14:14 |
Bevan Moss | Conditioning Station | Standard Operation | TM2 | | HV conditioning |
It was attempted to HV condition TM2 to 55kV and leave it operating there for an hour to demonstrate stability. Unfortunately at 52.65kV a spark destroyed the canbus controller. This controller had shown issues in the past but seemed to magically fixed itself. I will contact Hubert for another card. Attached is is a screen shot of the stip tools. |
Attachment 1: TM2_conditioning_03122013.JPG
|
|
568
|
Wednesday, December 04, 2013, 11:15 |
David Wang | ITE | Repair | TM4 | | New bolts are installed on ITE TP3. |
I installed 8 new bolts(3/8-16 UNC x1.25 STL) on the ITE TP3. The ITE TP3 replacement job is done. Everything is connected back to the pump. and it is ready for starting. |
573
|
Thursday, December 05, 2013, 14:55 |
David Wang | South Hot-Cell | Standard Operation | TM4 | | Leak check on TM4 target heat shield |
Chad and I leak checked TM4 heat shied water circuit at SHC. The pumping down was very good.Base leak rate 0.0xe-9 atm.cc/sec. BP 0.0xe-4torr. Sprayed helum twice on both VCR fittings.There is no response on leak detector. The circuit is leak tight. |
574
|
Thursday, December 05, 2013, 14:57 |
David Wang | ITE | Standard Operation | TM4 | | Connected TM4 in ITW |
I connected TM4 in ITE. All turbo pumps have been started and wok fine including new TP3. Everything is good so far. |
575
|
Friday, December 06, 2013, 15:09 |
Bevan Moss | Conditioning Station | Standard Operation | TM2 | | TM2 no source tray 55kV 1 hour |
Today 55kV was applied to TM2 and held for over 1 hour with the EINZEL at 27.5kV. There were 2 sparks and the current was unstable at this voltage but this test should be considered a success. Once again while bringing the voltage up the canbus continued to be a problem. After successfully passing the test I continued to raise the BIAS and EINZEL. A spark at 57kV tripped a controller for the vacuum and the canbus. As stated before I believe the module will reach 60kV and that there is an interaction between the EINZEL and the BIAS. I am not certain if that interaction is internal or external to the module. Attached is a screen shot and the dumped data. |
Attachment 1: 06122013_TM2_No_source_Tray_55kV_1_hour.JPG
|
|
Attachment 2: 06122013_TM2_No_Source_Tray_55kV_1_Hour.txt
|
Time TCS:IG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:DIC1:RDCOND [Mohm] TCS:BIAS:RDVOL [V] TCS:BIAS:RDCUR [uA] TCS:EL:RDVOL [V] TCS:EL:RDCUR [mA]
12/06/2013 10:34:30.138858 0.000000093 0.000000998 BadVal BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:31.138402 0.000000093 0.000000998 BadVal BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:32.138289 0.000000093 0.000001010 BadVal BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:33.138127 0.000000093 0.000000998 BadVal BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:34.138033 0.000000093 0.000000998 BadVal BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:35.137874 0.000000093 0.000000998 BadVal BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:36.137749 0.000000093 0.000000998 0.000000770 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:37.137657 0.000000093 0.000000998 0.000000770 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:38.137550 0.000000093 0.000000998 0.000000770 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:39.138452 0.000000093 0.000000998 0.000000770 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:40.138322 0.000000093 0.000000998 0.000000770 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:41.138150 0.000000094 0.000000998 0.000000770 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:42.139015 0.000000094 0.000000996 0.000000768 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:43.138906 0.000000093 0.000000998 0.000000770 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:44.138797 0.000000093 0.000000996 0.000000765 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:45.138654 0.000000094 0.000000998 0.000000770 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:46.144533 0.000000094 0.000000998 0.000000770 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:47.144548 0.000000094 0.000000998 0.000000770 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:48.144363 0.000000093 0.000000998 0.000000768 BadVal BadVal BadVal BadVal BadVal
12/06/2013 10:34:49.144158 0.000000093 0.000000996 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:34:50.144148 0.000000093 0.000000996 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:34:51.144894 0.000000094 0.000000998 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:34:52.144785 0.000000093 0.000000998 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:34:53.144636 0.000000094 0.000000998 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:34:54.144483 0.000000094 0.000000998 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:34:55.157531 0.000000094 0.000000998 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:34:56.158254 0.000000094 0.000000998 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:34:57.158119 0.000000094 0.000001032 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:34:58.157969 0.000000094 0.000001010 0.000000768 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:34:59.158877 0.000000093 0.000000998 0.000000768 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:35:00.159762 0.000000094 0.000000998 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:35:01.159615 0.000000094 0.000000998 0.000000770 16.8 BadVal BadVal BadVal BadVal
12/06/2013 10:35:03.306946 0.000000093 0.000000996 0.000000768 16.9 BadVal BadVal BadVal BadVal
12/06/2013 10:35:04.307252 0.000000094 0.000000998 0.000000768 16.9 27.46 BadVal BadVal BadVal
12/06/2013 10:35:05.308070 0.000000094 0.000000998 0.000000768 16.9 27.46 BadVal BadVal BadVal
12/06/2013 10:35:06.308956 0.000000094 0.000000994 0.000000770 16.9 27.46 BadVal BadVal BadVal
12/06/2013 10:35:07.308826 0.000000094 0.000000994 0.000000770 16.9 27.46 BadVal BadVal BadVal
12/06/2013 10:35:08.308694 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 BadVal BadVal
12/06/2013 10:35:09.308573 0.000000094 0.000000996 0.000000770 16.9 27.46 0.06 BadVal BadVal
12/06/2013 10:35:10.309442 0.000000094 0.000001010 0.000000770 16.9 27.46 0.06 BadVal BadVal
12/06/2013 10:35:11.309317 0.000000094 0.000000996 0.000000770 16.9 27.46 0.06 BadVal BadVal
12/06/2013 10:35:12.309197 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 BadVal BadVal
12/06/2013 10:35:13.309123 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 9.15 BadVal
12/06/2013 10:35:14.308964 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 9.15 BadVal
12/06/2013 10:35:15.309987 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 9.15 BadVal
12/06/2013 10:35:16.309785 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 9.15 BadVal
12/06/2013 10:35:17.309567 0.000000094 0.000000996 0.000000768 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:18.422297 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:19.422322 0.000000094 0.000000994 0.000000768 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:20.422292 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:21.422265 0.000000094 0.000001010 0.000000772 16.9 26.32 0.06 9.15 0.01
12/06/2013 10:35:22.422985 0.000000094 0.000001010 0.000000772 16.9 26.32 0.06 9.15 0.01
12/06/2013 10:35:23.532598 0.000000094 0.000000996 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:24.532696 0.000000094 0.000000996 0.000000772 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:25.700311 0.000000094 0.000000996 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:26.754388 0.000000094 0.000000996 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:27.754303 0.000000094 0.000000996 0.000000768 16.9 26.32 0.06 9.15 0.01
12/06/2013 10:35:28.754164 0.000000094 0.000000996 0.000000768 16.9 26.32 0.06 9.15 0.01
12/06/2013 10:35:29.808485 0.000000094 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:30.808903 0.000000094 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:31.892662 0.000000093 0.000000996 0.000000772 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:32.892649 0.000000094 0.000000994 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:33.892524 0.000000094 0.000000994 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:34.892399 0.000000093 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:36.59457 0.000000094 0.000000998 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:37.59452 0.000000094 0.000000998 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:38.58995 0.000000094 0.000000998 0.000000768 16.8 26.32 0.06 9.15 0.01
12/06/2013 10:35:39.58868 0.000000094 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:40.58702 0.000000094 0.000000998 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:41.59611 0.000000093 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:42.59451 0.000000093 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:43.59465 0.000000094 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:44.69481 0.000000094 0.000000998 0.000000770 16.8 27.46 0.06 8.54 0.01
12/06/2013 10:35:45.70113 0.000000094 0.000000998 0.000000770 16.8 27.46 0.06 8.54 0.01
12/06/2013 10:35:46.69968 0.000000094 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:47.69843 0.000000094 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:48.69730 0.000000093 0.000000996 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:49.69609 0.000000093 0.000000998 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:50.69501 0.000000093 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:51.70349 0.000000094 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:35:52.70327 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:53.71064 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:54.71157 0.000000094 0.000000996 0.000000768 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:55.70854 0.000000093 0.000000998 0.000000768 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:56.70728 0.000000093 0.000000996 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:57.70696 0.000000093 0.000000998 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:58.71465 0.000000094 0.000000998 0.000000772 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:35:59.71304 0.000000094 0.000000998 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:36:00.72214 0.000000093 0.000000998 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:36:01.72058 0.000000093 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:02.72037 0.000000094 0.000000996 0.000000765 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:03.71845 0.000000093 0.000000996 0.000000768 16.8 26.32 0.06 9.15 0.01
12/06/2013 10:36:04.71718 0.000000093 0.000000996 0.000000770 16.8 26.32 0.06 9.15 0.01
12/06/2013 10:36:05.71547 0.000000093 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:06.72545 0.000000094 0.000000996 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:07.72467 0.000000093 0.000000996 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:08.73208 0.000000094 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:09.73087 0.000000093 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:10.73946 0.000000093 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:11.74864 0.000000093 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:12.74666 0.000000093 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:13.75645 0.000000093 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:14.75641 0.000000093 0.000000998 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:15.75369 0.000000093 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:16.136319 0.000000093 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:17.136267 0.000000093 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:18.230037 0.000000094 0.000000998 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:19.229817 0.000000093 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:20.229681 0.000000093 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:21.229580 0.000000093 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:22.229431 0.000000093 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:23.229311 0.000000093 0.000000998 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:24.229201 0.000000093 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:25.229010 0.000000093 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:26.228930 0.000000094 0.000000994 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:27.273591 0.000000094 0.000000998 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:28.273699 0.000000093 0.000000998 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:29.274782 0.000000094 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:30.274160 0.000000094 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:31.274279 0.000000094 0.000000998 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:32.274186 0.000000093 0.000000998 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:33.276910 0.000000093 0.000000998 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:34.276923 0.000000094 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:35.277751 0.000000094 0.000000998 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:36.277627 0.000000094 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:37.277496 0.000000094 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:38.277402 0.000000093 0.000000998 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:39.277265 0.000000093 0.000000998 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:40.277272 0.000000093 0.000001010 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:41.278116 0.000000093 0.000000998 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:42.277876 0.000000093 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:43.277804 0.000000094 0.000000998 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:44.277667 0.000000093 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:45.277528 0.000000094 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:46.279324 0.000000094 0.000000998 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:47.279479 0.000000093 0.000000998 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:48.280171 0.000000094 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:49.280032 0.000000094 0.000000998 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:50.279918 0.000000093 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:51.280727 0.000000093 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:52.280665 0.000000093 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:53.280477 0.000000093 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:54.280361 0.000000093 0.000000996 0.000000770 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:55.280370 0.000000094 0.000000994 0.000000770 16.7 27.46 0.06 9.76 0.01
12/06/2013 10:36:56.281267 0.000000094 0.000000996 0.000000768 16.7 27.46 0.06 9.15 0.01
12/06/2013 10:36:57.281021 0.000000093 0.000000996 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:58.280911 0.000000094 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:36:59.280785 0.000000093 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:00.280647 0.000000094 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:01.281537 0.000000094 0.000000996 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:02.281408 0.000000093 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:03.281254 0.000000094 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:04.281106 0.000000094 0.000000998 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:05.281008 0.000000093 0.000000998 0.000000768 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:06.281889 0.000000094 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:07.281764 0.000000093 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:08.281734 0.000000093 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:09.281500 0.000000093 0.000000998 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:10.281385 0.000000094 0.000000994 0.000000770 16.8 27.46 0.06 9.15 0.01
12/06/2013 10:37:11.282277 0.000000094 0.000000996 0.000000770 16.9 27.46 0.06 9.76 0.01
12/06/2013 10:37:12.282243 0.000000093 0.000000998 0.000000768 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:37:13.282030 0.000000094 0.000000996 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:37:14.281905 0.000000093 0.000000998 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:37:15.281781 0.000000093 0.000000998 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:37:16.282607 0.000000093 0.000000996 0.000000770 16.9 27.46 0.06 9.15 0.01
12/06/2013 10:37:17.282622 0.000000093 0.000000998 0.000000768 16.9 6.86 1.03 9.15 0.01
12/06/2013 10:37:18.282434 0.000000094 0.000000998 0.000000770 16.9 6.86 1.03 1.22 0.01
12/06/2013 10:37:19.282257 0.000000094 0.000000998 0.000000770 16.9 3.43 1.03 1.22 0.01
12/06/2013 10:37:20.282499 0.000000094 0.000000998 0.000000770 16.9 4.57 1.03 1.83 0.01
12/06/2013 10:37:21.283005 0.000000094 0.000000998 0.000000770 16.9 4.57 1.03 493.17 0.01
12/06/2013 10:37:22.283870 0.000000093 0.000000998 0.000000770 16.9 4.57 1.03 993.05 0.01
12/06/2013 10:37:23.283923 0.000000094 0.000000998 0.000000770 16.9 6.86 0.91 1494.16 0.01
12/06/2013 10:37:24.283648 0.000000093 0.000000996 0.000000770 16.9 3.43 1.15 1494.16 0.01
12/06/2013 10:37:25.283492 0.000000094 0.000000998 0.000000770 16.9 13.73 1.15 1994.04 0.28
12/06/2013 10:37:26.283509 0.000000094 0.000000998 0.000000770 16.9 13.73 1.15 1994.04 0.08
12/06/2013 10:37:27.283262 0.000000093 0.000000998 0.000000770 16.8 5.72 0.85 2494.54 0.10
12/06/2013 10:37:28.283071 0.000000093 0.000000998 0.000000770 16.8 2.28 0.97 2995.04 0.10
12/06/2013 10:37:29.282990 0.000000094 0.000000998 0.000000770 16.8 2.28 0.97 3495.53 0.10
12/06/2013 10:37:30.282877 0.000000093 0.000000998 0.000000770 16.8 10.29 0.97 3994.81 0.15
12/06/2013 10:37:31.283728 0.000000094 0.000000996 0.000000768 16.8 8.01 0.91 3994.81 0.15
12/06/2013 10:37:32.283568 0.000000094 0.000000998 0.000000768 16.8 4.57 1.15 3996.03 0.15
12/06/2013 10:37:33.283508 0.000000093 0.000000998 0.000000770 16.8 6.86 1.15 3996.03 0.15
12/06/2013 10:37:34.283108 0.000000094 0.000000998 0.000000768 16.8 4.57 1.03 3996.03 0.15
12/06/2013 10:37:35.283283 0.000000094 0.000000998 0.000000768 16.8 5.72 1.03 3996.03 0.15
12/06/2013 10:37:36.284116 0.000000093 0.000000994 0.000000768 16.8 5.72 1.09 3996.03 0.15
12/06/2013 10:37:37.283983 0.000000094 0.000000998 0.000000770 16.8 5.72 1.09 3996.64 0.15
12/06/2013 10:37:38.283864 0.000000094 0.000000998 0.000000770 16.7 3.43 1.09 3996.03 0.15
12/06/2013 10:37:39.472917 0.000000094 0.000000998 0.000000765 16.7 3.43 1.09 3996.64 0.15
12/06/2013 10:37:40.472581 0.000000093 0.000000996 0.000000768 16.7 2.28 1.15 3996.64 0.15
12/06/2013 10:37:41.472472 0.000000094 0.000000998 0.000000770 16.7 2.28 1.15 3996.64 0.15
12/06/2013 10:37:42.472333 0.000000094 0.000000998 0.000000768 16.8 8.01 1.03 3996.64 0.15
12/06/2013 10:37:43.472212 0.000000094 0.000000998 0.000000770 16.8 8.01 1.03 3996.64 0.15
12/06/2013 10:37:44.738171 0.000000094 0.000000998 0.000000770 16.8 9.15 1.03 3996.64 0.15
12/06/2013 10:37:45.737929 0.000000093 0.000000998 0.000000770 16.8 9.15 1.03 3996.03 0.15
12/06/2013 10:37:46.737758 0.000000093 0.000000996 0.000000768 16.8 10.29 1.03 3996.64 0.15
12/06/2013 10:37:47.737679 0.000000094 0.000000996 0.000000770 16.8 8.01 0.91 3996.64 0.15
12/06/2013 10:37:48.737550 0.000000094 0.000000998 0.000000768 16.8 5.72 1.15 3996.64 0.15
12/06/2013 10:37:49.737448 0.000000094 0.000000998 0.000000768 16.8 5.72 1.15 4276.79 0.15
12/06/2013 10:37:50.737254 0.000000094 0.000000998 0.000000770 16.8 3.43 0.97 4997.02 0.15
12/06/2013 10:37:51.738371 0.000000093 0.000000996 0.000000770 16.8 12.58 0.91 5997.40 0.44
12/06/2013 10:37:52.739018 0.000000094 0.000000996 0.000000770 16.8 12.58 1.15 7996.33 0.49
12/06/2013 10:37:53.739981 0.000000094 0.000000998 0.000000770 16.9 1.14 1.15 9499.65 0.29
12/06/2013 10:37:54.739743 0.000000094 0.000000998 0.000000770 16.9 1.14 1.15 10997.48 0.59
12/06/2013 10:37:55.739858 0.000000094 0.000000996 0.000000770 16.9 14.87 1.15 11999.69 0.42
12/06/2013 10:37:56.740534 0.000000094 0.000001010 0.000000770 16.9 14.87 1.15 13499.35 0.47
12/06/2013 10:37:57.740392 0.000000094 0.000000998 0.000000765 16.9 3.43 1.15 15000.83 0.49
12/06/2013 10:37:58.740247 0.000000094 0.000000998 0.000000768 16.8 3.43 1.15 16499.88 0.57
12/06/2013 10:37:59.740213 0.000000094 0.000000998 0.000000768 16.8 12.58 1.15 18001.98 0.63
12/06/2013 10:38:00.740039 0.000000093 0.000000998 0.000000768 16.8 12.58 1.15 19068.89 0.65
12/06/2013 10:38:01.739890 0.000000093 0.000000998 0.000000774 16.8 10.29 0.97 20003.35 0.65
12/06/2013 10:38:02.739822 0.000000093 0.000000998 0.000000770 16.8 10.29 0.97 20003.35 0.65
12/06/2013 10:38:03.740608 0.000000093 0.000000998 0.000000770 16.8 1007.09 4.08 20005.18 0.65
12/06/2013 10:38:04.740535 0.000000094 0.000000998 0.000000768 16.8 2009.61 2.38 20005.18 0.65
12/06/2013 10:38:05.740421 0.000000094 0.000000998 0.000000768 16.8 3292.51 4.33 20005.18 0.65
12/06/2013 10:38:06.741299 0.000000093 0.000000998 0.000000770 16.8 4510.18 7.87 20005.18 0.65
12/06/2013 10:38:07.741154 0.000000094 0.000000998 0.000000770 16.8 5794.23 7.01 20005.79 0.65
12/06/2013 10:38:08.740978 0.000000094 0.000000994 0.000000770 16.8 7014.19 10.80 20005.79 0.65
12/06/2013 10:38:09.740907 0.000000093 0.000000998 0.000000768 16.8 8294.80 13.91 20005.79 0.65
12/06/2013 10:38:10.741753 0.000000093 0.000000998 0.000000768 16.8 10017.16 14.58 20005.79 0.65
12/06/2013 10:38:11.742650 0.000000094 0.000000996 0.000000770 16.8 11519.79 19.28 20005.79 0.65
12/06/2013 10:38:12.742528 0.000000093 0.000000996 0.000000770 16.8 12021.05 12.81 20005.79 0.65
12/06/2013 10:38:13.742395 0.000000093 0.000000998 0.000000770 16.8 12522.31 12.08 20005.79 0.65
12/06/2013 10:38:14.742226 0.000000093 0.000000998 0.000000770 16.8 13021.28 12.26 20005.79 0.65
12/06/2013 10:38:15.742200 0.000000094 0.000000998 0.000000768 16.8 13801.78 12.57 20005.79 0.65
12/06/2013 10:38:16.742099 0.000000094 0.000000998 0.000000770 16.8 14522.77 17.39 20005.79 0.65
12/06/2013 10:38:17.742891 0.000000093 0.000000996 0.000000768 16.8 15024.03 15.80 20005.79 0.65
12/06/2013 10:38:18.742772 0.000000093 0.000000998 0.000000768 16.8 15524.14 14.89 20005.79 0.65
12/06/2013 10:38:19.742602 0.000000093 0.000000998 0.000000768 16.8 16524.37 18.73 20005.79 0.65
12/06/2013 10:38:20.742477 0.000000093 0.000000998 0.000000768 16.8 17026.77 17.27 20005.79 0.65
12/06/2013 10:38:21.743352 0.000000093 0.000000996 0.000000770 16.8 18030.44 20.81 20005.79 0.65
12/06/2013 10:38:22.743286 0.000000093 0.000000996 0.000000770 16.8 18527.12 18.67 20005.79 0.65
12/06/2013 10:38:23.743116 0.000000093 0.000000998 0.000000770 16.8 19528.49 22.64 20005.79 0.65
12/06/2013 10:38:24.743988 0.000000093 0.000000996 0.000000765 16.8 20029.75 21.17 20005.79 0.65
12/06/2013 10:38:25.743892 0.000000093 0.000000996 0.000000768 16.8 20529.86 20.38 20005.79 0.65
12/06/2013 10:38:26.744754 0.000000093 0.000000998 0.000000770 16.8 21530.09 25.63 20005.79 0.65
12/06/2013 10:38:27.744640 0.000000094 0.000000998 0.000000768 16.8 22031.35 23.49 20005.79 0.65
12/06/2013 10:38:28.744504 0.000000093 0.000000998 0.000000768 16.8 22532.61 22.94 20005.79 0.65
12/06/2013 10:38:29.745410 0.000000094 0.000000998 0.000000768 16.8 23032.73 22.70 20005.79 0.65
12/06/2013 10:38:30.745262 0.000000094 0.000000998 0.000000770 16.8 23533.98 27.52 20005.79 0.65
12/06/2013 10:38:31.745131 0.000000094 0.000000996 0.000000772 16.8 24533.07 26.36 20005.79 0.65
12/06/2013 10:38:32.745008 0.000000094 0.000000998 0.000000768 16.7 25034.33 25.63 20005.79 0.65
12/06/2013 10:38:33.745050 0.000000093 0.000000998 0.000000770 16.7 26034.56 29.90 20005.79 0.65
12/06/2013 10:38:34.744755 0.000000094 0.000001010 0.000000768 16.7 26535.82 28.25 20005.79 0.65
12/06/2013 10:38:35.744622 0.000000093 0.000000998 0.000000770 16.7 27035.93 27.34 20005.79 0.65
12/06/2013 10:38:36.745477 0.000000093 0.000000998 0.000000768 16.7 27989.24 31.73 20005.79 0.65
12/06/2013 10:38:37.746375 0.000000093 0.000000998 0.000000768 16.7 28536.27 30.94 20005.79 0.65
12/06/2013 10:38:38.746259 0.000000094 0.000000998 0.000000770 16.7 29037.53 30.88 20005.79 0.65
12/06/2013 10:38:39.746094 0.000000094 0.000000996 0.000000770 16.7 29538.79 30.51 20005.79 0.65
12/06/2013 10:38:40.746006 0.000000093 0.000000998 0.000000768 16.7 30038.91 30.45 20005.79 0.65
12/06/2013 10:38:41.745828 0.000000093 0.000000998 0.000000770 16.7 30539.02 30.70 20005.79 0.65
12/06/2013 10:38:42.745708 0.000000093 0.000000994 0.000000768 16.7 31040.28 31.55 20005.79 0.65
12/06/2013 10:38:43.746645 0.000000094 0.000000994 0.000000770 16.7 31993.59 36.07 20005.79 0.65
12/06/2013 10:38:44.746538 0.000000093 0.000000998 0.000000765 16.7 32540.62 35.82 20005.79 0.65
12/06/2013 10:38:45.746327 0.000000093 0.000000998 0.000000765 16.7 33040.74 35.15 20005.79 0.65
12/06/2013 10:38:46.747194 0.000000093 0.000001010 0.000000770 16.7 33540.85 34.79 20005.79 0.65
12/06/2013 10:38:47.747076 0.000000093 0.000000996 0.000000770 16.7 34545.66 38.81 20005.79 0.65
12/06/2013 10:38:48.746949 0.000000093 0.000000998 0.000000768 16.7 35042.34 37.17 20005.79 0.65
12/06/2013 10:38:49.747854 0.000000094 0.000000998 0.000000770 16.8 36041.42 46.81 20005.79 0.65
12/06/2013 10:38:50.747794 0.000000093 0.000000996 0.000000768 16.8 36543.83 40.03 20005.79 0.65
12/06/2013 10:38:51.748607 0.000000094 0.000000998 0.000000770 16.8 37043.94 39.61 20005.79 0.65
12/06/2013 10:38:52.748492 0.000000093 0.000000998 0.000000770 16.8 37545.20 39.73 20005.79 0.65
12/06/2013 10:38:53.748395 0.000000093 0.000000998 0.000000768 16.8 38046.46 44.06 20005.79 0.65
12/06/2013 10:38:54.748195 0.000000093 0.000000996 0.000000768 16.8 39044.40 43.03 20005.79 0.65
12/06/2013 10:38:55.748153 0.000000094 0.000000998 0.000000770 16.8 39545.66 43.45 20005.79 0.65
12/06/2013 10:38:56.749112 0.000000094 0.000000998 0.000000770 16.8 39545.66 40.89 20005.79 0.65
12/06/2013 10:38:57.748818 0.000000094 0.000000998 0.000000770 16.8 40046.92 41.50 20005.79 0.65
12/06/2013 10:38:58.748731 0.000000093 0.000000998 0.000000768 16.8 40046.92 41.07 20005.79 0.65
12/06/2013 10:38:59.748612 0.000000094 0.000000996 0.000000768 16.8 40046.92 40.89 20005.79 0.65
12/06/2013 10:39:00.748440 0.000000094 0.000000996 0.000000768 16.8 40046.92 40.89 20005.79 0.65
12/06/2013 10:39:01.749351 0.000000094 0.000001010 0.000000770 16.8 40046.92 40.89 20005.79 0.65
12/06/2013 10:39:02.749233 0.000000094 0.000000996 0.000000770 16.8 40048.06 40.83 20006.40 0.65
12/06/2013 10:39:03.749082 0.000000094 0.000000998 0.000000770 16.8 40048.06 40.83 20006.40 0.65
12/06/2013 10:39:04.749026 0.000000093 0.000000998 0.000000765 16.8 40046.92 40.83 20005.79 0.65
12/06/2013 10:39:05.749899 0.000000094 0.000000998 0.000000768 16.8 40046.92 40.83 20005.79 0.65
12/06/2013 10:39:06.750723 0.000000093 0.000000998 0.000000770 16.8 40046.92 40.83 20005.79 0.65
12/06/2013 10:39:07.750716 0.000000093 0.000000998 0.000000770 16.8 40046.92 40.83 20005.79 0.65
12/06/2013 10:39:08.750436 0.000000093 0.000000998 0.000000770 16.8 40048.06 40.83 20005.79 0.65
12/06/2013 10:39:09.750420 0.000000093 0.000000998 0.000000770 16.8 40046.92 41.32 20005.79 0.65
12/06/2013 10:39:10.750265 0.000000093 0.000000998 0.000000770 16.8 40048.06 40.71 20005.79 0.65
12/06/2013 10:39:11.751047 0.000000093 0.000000996 0.000000768 16.8 40048.06 40.71 20005.79 0.65
12/06/2013 10:39:12.750973 0.000000094 0.000000996 0.000000770 16.8 40048.06 40.71 20005.79 0.65
12/06/2013 10:39:13.751821 0.000000094 0.000000998 0.000000770 16.8 40048.06 40.71 20005.79 0.65
12/06/2013 10:39:14.751678 0.000000094 0.000000996 0.000000770 16.8 40048.06 40.71 20005.79 0.65
12/06/2013 10:39:15.751659 0.000000094 0.000000996 0.000000770 16.8 40048.06 40.71 20005.79 0.65
12/06/2013 10:39:16.752539 0.000000094 0.000000998 0.000000772 16.8 40048.06 40.71 20503.85 0.71
12/06/2013 10:39:17.753413 0.000000094 0.000000996 0.000000770 16.8 40048.06 40.71 21004.34 0.71
12/06/2013 10:39:18.753168 0.000000094 0.000000998 0.000000770 16.8 40048.06 40.71 21504.23 0.71
12/06/2013 10:39:19.753173 0.000000093 0.000000998 0.000000772 16.7 40048.06 40.58 22070.64 0.76
12/06/2013 10:39:20.752945 0.000000093 0.000000994 0.000000768 16.7 40048.06 40.58 23000.83 0.99
12/06/2013 10:39:21.753831 0.000000094 0.000000996 0.000000772 16.7 40048.06 40.58 23503.16 0.80
12/06/2013 10:39:22.753731 0.000000093 0.000000996 0.000000772 16.7 40048.06 40.58 24003.66 0.80
12/06/2013 10:39:23.753588 0.000000093 0.000000996 0.000000770 16.7 40048.06 40.58 24501.71 0.85
12/06/2013 10:39:24.754474 0.000000094 0.000000998 0.000000765 16.7 40048.06 40.58 25003.43 0.87
12/06/2013 10:39:25.754339 0.000000094 0.000000998 0.000000770 16.7 40048.06 40.71 25503.31 0.87
12/06/2013 10:39:26.754168 0.000000094 0.000000998 0.000000772 16.7 40048.06 40.71 25953.15 0.87
12/06/2013 10:39:27.754087 0.000000093 0.000000998 0.000000772 16.8 40048.06 40.71 26003.20 0.87
12/06/2013 10:39:28.754026 0.000000094 0.000000998 0.000000770 16.8 40048.06 40.71 26503.70 0.99
12/06/2013 10:39:29.753829 0.000000093 0.000000998 0.000000770 16.8 40048.06 40.71 26572.67 0.99
12/06/2013 10:39:30.753655 0.000000093 0.000000998 0.000000770 16.8 40048.06 40.71 27503.47 0.95
... 14427 more lines ...
|
577
|
Monday, December 09, 2013, 14:47 |
David Wang | ITE | Standard Operation | TM4 | | I moved 5 shielding blocks from block storage area to ITE. |
I moved 5 shielding blocks to ITE. The ITE is configured to take proton beam. |
578
|
Thursday, December 12, 2013, 11:14 |
Bevan Moss | Conditioning Station | Standard Operation | TM2 | | HV Chase Electrical Test |
While under vacuum Travis and I completed diagnostics of the HV chase. Majority of the lines showed OL at 1kV but there were the following "failures"
A to P @ 250V 716kOhm
A to Q @ 1kV 25.18MOhm
B to C with ohm meter 8Mohm @250V 830kOhm
B to D @ 1kV 15.57MOhm
C to D @1kV 16.18 MOhm
P to Q @1kV 1.069 GOhm
G to J with ohm meter dead short.
Ideally all of these values would be OL and they may improve or get worse when the source tray is installed depending on where the electrical contact is. I need to discuss with Friedhelm but I believe that as these values the module can still operate. Without changing the HV chase there is very little chance of improving these values. |
579
|
Thursday, January 09, 2014, 11:07 |
chad fisher | South Hot-Cell | Maintenance | | | Field Level |
I have managed to reduce the field at the broken manipulator from 12 mSv/h to 400 uSv/h. |