Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC, Page 39 of 140  Not logged in ELOG logo
ID Date Author Category Type Moduledown Target/Number Subject
  332   Wednesday, May 08, 2013, 10:12 chad fisherSouth Hot-CellRepairTM3 TM3 9 pin wiring removal

The 9 pin wiring has successfully been removed from TM3.

Attachment 1: IMG_1055[1].JPG
IMG_1055[1].JPG
  333   Wednesday, May 08, 2013, 13:48 chad fisherSouth Hot-CellRepairTM3 IMG wiring check

Checks of the wiring for the IMG are complete and have passed.

  335   Thursday, May 09, 2013, 14:23 chad fisherSouth Hot-CellRepairTM3 Water Block Jig Removal

The source tray side of the water block jig has been removed in preparation for moving the module to the  conditioning station for electrical tests.

Attachment 1: IMG_1059[1].JPG
IMG_1059[1].JPG
  336   Friday, May 10, 2013, 09:26 chad fisherSouth Hot-CellRepairTM3 Containment box reinstalled

the containment box has been reinstalled onto TM3. After electrical checks it is ready to move to the conditioning station...for electrical tests.

Attachment 1: IMG_1062[1].JPG
IMG_1062[1].JPG
Attachment 2: IMG_1063[1].JPG
IMG_1063[1].JPG
  337   Friday, May 10, 2013, 11:02 Travis CaveSouth Hot-CellStandard OperationTM3no targetmodule move

TM#3 with no target and no source tray has been moved from the south hot cell to the conditioning station.

  338   Friday, May 10, 2013, 11:11 Travis CaveSouth Hot-CellStandard OperationTM3no targetElectrical check

TM#3 electrical check with no target and no source tray, see pdf.

Attachment 1: TM#3_elec_chk_no_tgt_no_tray.PDF
TM#3_elec_chk_no_tgt_no_tray.PDF
  339   Friday, May 10, 2013, 11:28 Bevan MossConditioning StationStandard OperationTM3No Source TrayRoughing Started

 Roughing on TM3 was started at 11:26am today

  340   Friday, May 10, 2013, 14:05 Bevan MossConditioning StationStandard OperationTM3No Source TrayTurbo Pumps On

The turbo pumps are on. TP1 and TP2 once again timed out and had to be restarted before they would stay on.

  341   Monday, May 13, 2013, 14:59 Bevan MossConditioning StationStandard OperationTM3N/AEL testing

Bevan Moss wrote:

This morning the Einzel Lens was tested on TM3 as the intention is to reuse this piece of equipment. The EL was able to achieve 39.9kV at ~1.35mA before a major spark happened and the power supply turned off. Also during testing the penning gauge suddenly shot up after a spark, it did not recover and had been acting strange in previous test, it was decided to ignore its value and continue testing but it should be replaced in the future. When I went to save the strip tool data I tried to save it as SDDS binary data out of curiosity and the tool crashed, it turns out this is on old feature and doesn't work anymore. A file was created but I cannot recover any of the data. If I do manage to do so I will will attach it later. Attached is the RGA and Archiver data. 

Other items of note:

Voltage was increased in 1000V increments until ~32kV when it started to have sparks. Increases were then reduced to 500V until 38kV when it sparked and further reduced to 100V increments where it worked until 39.9kV

There is a inline and ballast resistor on the EL circuit values of each respectively are 145Kohm and 200 Mohm

 

The rga application is available at
http://www.thinksrs.com/downloads/soft.htm

 

 The lost Binary file. Binary files are no longer used and cause the the tool to crash. The option has not been removed from the strip tool users are just supposed to know not to use it.

Attachment 1: TM3_EL_39.9kV_23042013.txt
SDDS1
&description text="", contents="StripTool data", &end
&column name=Time, units=seconds, type=double,  &end
&column name=TCS:IG1:RDVAC, units=T, description="subroutine record", format_string=%23.9g, type=double,  &end
&column name=TCS:PNG1:RDVAC, units=T, description="subroutine record", format_string=%23.9g, type=double,  &end
&column name=TCS:IG2:RDVAC, units=T, description="subroutine record", format_string=%23.9g, type=double,  &end
&column name=TCS:IG1S:RDVAC, units=T, description="subroutine record", format_string=%23.9g, type=double,  &end
&column name=TCS:DIC1:RDCOND, units=Mohm, description="analog input record", format_string=%23.1g, type=double,  &end
&column name=TCS:EL:RDVOL, units=V, description="analog input record", format_string=%23.2g, type=double,  &end
&column name=TCS:EL:RDCUR, units=mA, description="analog input record", format_string=%23.2g, type=double,  &end
&data mode=ascii, &end
! page number 1
                2573
 1.366741631688000e+09  9.571430206298828e-07  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741632687000e+09  9.615384101867676e-07  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741633687000e+09  9.593406677246093e-07  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741634927000e+09  9.593406677246093e-07  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741635927000e+09  9.637361526489257e-07  7.450549602508544e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741636927000e+09  9.571430206298828e-07  7.428572654724120e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741637927000e+09  9.571430206298828e-07  7.428572654724120e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741638927000e+09  9.593406677246093e-07  7.428572654724120e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741639927000e+09  9.593406677246093e-07  7.428572654724120e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741640927000e+09  9.615384101867676e-07  7.450549602508544e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741641927000e+09  9.615384101867676e-07  7.450549602508544e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741643915000e+09  9.615384101867676e-07  7.450549602508544e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741644916000e+09  9.615384101867676e-07  7.428572654724120e-06  4.813187122344971e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741645917000e+09  9.593406677246093e-07  7.428572654724120e-06  4.813187122344971e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741646916000e+09  9.615384101867676e-07  7.406591415405273e-06  4.813187122344971e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741647916000e+09  9.615384101867676e-07  7.428572654724120e-06  4.813187122344971e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741648916000e+09  9.593406677246093e-07  7.428572654724120e-06  4.813187122344971e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741649916000e+09  9.615384101867676e-07  7.428572654724120e-06  4.813187122344971e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741650917000e+09  9.615384101867676e-07  7.428572654724120e-06  4.813187122344971e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741651917000e+09  9.615384101867676e-07  7.450549602508544e-06  4.791210174560547e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741655334000e+09  9.615384101867676e-07  7.428572654724120e-06  4.791210174560547e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741656334000e+09  9.593406677246093e-07  7.428572654724120e-06  4.791210174560547e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741657334000e+09  9.593406677246093e-07  7.428572654724120e-06  4.791210174560547e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741658334000e+09  9.593406677246093e-07  7.428572654724120e-06  4.813187122344971e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741659334000e+09  9.571430206298828e-07  7.450549602508544e-06  4.791210174560547e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741660334000e+09  9.615384101867676e-07  7.450549602508544e-06  4.813187122344971e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741661335000e+09  9.593406677246093e-07  7.450549602508544e-06  4.813187122344971e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741662335000e+09  9.593406677246093e-07  7.428572654724120e-06  4.791210174560547e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741663528000e+09  9.593406677246093e-07  7.450549602508544e-06  4.791210174560547e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741664661000e+09  9.593406677246093e-07  7.428572654724120e-06  4.813187122344971e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741665662000e+09  9.549448966979981e-07  7.428572654724120e-06  4.835164070129395e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741666662000e+09  9.593406677246093e-07  7.428572654724120e-06  4.835164070129395e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741667662000e+09  9.593406677246093e-07  7.450549602508544e-06  4.791210174560547e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741668662000e+09  9.593406677246093e-07  7.450549602508544e-06  4.835164070129395e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741669662000e+09  9.593406677246093e-07  7.450549602508544e-06  4.791210174560547e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741670663000e+09  9.593406677246093e-07  7.450549602508544e-06  4.791210174560547e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741671662000e+09  9.571430206298828e-07  7.450549602508544e-06  4.791210174560547e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741672662000e+09  9.615384101867676e-07  7.428572654724120e-06  4.791210174560547e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741673662000e+09  9.593406677246093e-07  7.428572654724120e-06  4.791210174560547e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741674663000e+09  9.593406677246093e-07  7.428572654724120e-06  4.769228935241699e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741675664000e+09  9.615384101867676e-07  7.450549602508544e-06  4.791210174560547e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741676664000e+09  9.593406677246093e-07  7.450549602508544e-06  4.791210174560547e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741677665000e+09  9.593406677246093e-07  7.450549602508544e-06  4.791210174560547e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741678664000e+09  9.593406677246093e-07  7.450549602508544e-06  4.791210174560547e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741679664000e+09  9.593406677246093e-07  7.450549602508544e-06  4.791210174560547e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741680665000e+09  9.593406677246093e-07  7.450549602508544e-06  4.813187122344971e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741681665000e+09  9.615384101867676e-07  7.450549602508544e-06  4.791210174560547e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741682665000e+09  9.593406677246093e-07  7.450549602508544e-06  4.813187122344971e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741683665000e+09  9.549448966979981e-07  7.450549602508544e-06  4.835164070129395e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741684665000e+09  9.571430206298828e-07  7.450549602508544e-06  4.835164070129395e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741685713000e+09  9.593406677246093e-07  7.450549602508544e-06  4.813187122344971e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741686714000e+09  9.593406677246093e-07  7.450549602508544e-06  4.813187122344971e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741687713000e+09  9.593406677246093e-07  7.450549602508544e-06  4.813187122344971e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741688713000e+09  9.615384101867676e-07  7.450549602508544e-06  4.813187122344971e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741689714000e+09  9.571430206298828e-07  7.450549602508544e-06  4.813187122344971e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741690735000e+09  9.615384101867676e-07  7.450549602508544e-06  4.769228935241699e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741691734000e+09  9.571430206298828e-07  7.450549602508544e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741692734000e+09  9.637361526489257e-07  7.516484737396240e-06  6.593405723571777e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741693734000e+09  9.659341812133788e-07  7.560438632965087e-06  6.483516693115234e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741694769000e+09  9.659341812133788e-07  7.560438632965087e-06  5.362636566162109e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741695769000e+09  9.615384101867676e-07  7.538461685180663e-06  5.362636566162109e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741696769000e+09  9.615384101867676e-07  7.494503498077392e-06  5.230770587921142e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741697916000e+09  9.615384101867676e-07  7.472526550292968e-06  5.164835453033447e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741698916000e+09  9.615384101867676e-07  7.472526550292968e-06  5.120877265930176e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741699916000e+09  9.615384101867676e-07  7.472526550292968e-06  5.098900318145752e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741700916000e+09  9.593406677246093e-07  7.472526550292968e-06  5.076923370361328e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741702180000e+09  9.593406677246093e-07  7.472526550292968e-06  5.054946422576904e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741703180000e+09  9.615384101867676e-07  7.472526550292968e-06  5.010988235473633e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741704180000e+09  9.615384101867676e-07  7.472526550292968e-06  5.010988235473633e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741705181000e+09  9.615384101867676e-07  7.472526550292968e-06  5.010988235473633e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741706182000e+09  9.615384101867676e-07  7.450549602508544e-06  4.989011287689209e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741707182000e+09  9.593406677246093e-07  7.450549602508544e-06  4.989011287689209e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741708182000e+09  9.615384101867676e-07  7.450549602508544e-06  4.967034339904785e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741709183000e+09  9.571430206298828e-07  7.450549602508544e-06  4.967034339904785e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741710183000e+09  9.615384101867676e-07  7.450549602508544e-06  4.967034339904785e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741711183000e+09  9.593406677246093e-07  7.450549602508544e-06  4.967034339904785e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741712183000e+09  9.593406677246093e-07  7.472526550292968e-06  4.945053100585938e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741713183000e+09  9.615384101867676e-07  7.450549602508544e-06  4.945053100585938e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741714183000e+09  9.615384101867676e-07  7.428572654724120e-06  4.945053100585938e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741715183000e+09  9.615384101867676e-07  7.450549602508544e-06  4.945053100585938e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741716183000e+09  9.615384101867676e-07  7.450549602508544e-06  4.945053100585938e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741717183000e+09  9.593406677246093e-07  7.450549602508544e-06  4.945053100585938e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741718184000e+09  9.637361526489257e-07  7.450549602508544e-06  4.967034339904785e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741719183000e+09  9.593406677246093e-07  7.450549602508544e-06  4.967034339904785e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741720183000e+09  9.593406677246093e-07  7.450549602508544e-06  4.945053100585938e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741721184000e+09  9.593406677246093e-07  7.450549602508544e-06  4.945053100585938e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741722184000e+09  9.593406677246093e-07  7.450549602508544e-06  4.945053100585938e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741723408000e+09  9.571430206298828e-07  7.450549602508544e-06  4.945053100585938e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741724409000e+09  9.593406677246093e-07  7.450549602508544e-06  4.901099205017090e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741725410000e+09  9.615384101867676e-07  7.450549602508544e-06  4.901099205017090e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741726410000e+09  9.593406677246093e-07  7.450549602508544e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741727409000e+09  9.593406677246093e-07  7.450549602508544e-06  4.901099205017090e-06  1.604393959045410e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741728476000e+09  9.593406677246093e-07  7.450549602508544e-06  4.901099205017090e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741729476000e+09  9.571430206298828e-07  7.450549602508544e-06  4.901099205017090e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741730477000e+09  9.571430206298828e-07  7.450549602508544e-06  4.923076152801514e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741731477000e+09  9.615384101867676e-07  7.450549602508544e-06  4.923076152801514e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741732477000e+09  9.593406677246093e-07  7.450549602508544e-06  4.923076152801514e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741733477000e+09  9.593406677246093e-07  7.450549602508544e-06  4.923076152801514e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741734784000e+09  9.615384101867676e-07  7.450549602508544e-06  4.923076152801514e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741735784000e+09  9.571430206298828e-07  7.450549602508544e-06  4.901099205017090e-06  1.516481876373291e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741736785000e+09  9.549448966979981e-07  7.450549602508544e-06  4.923076152801514e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741737785000e+09  9.571430206298828e-07  7.450549602508544e-06  4.923076152801514e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741738785000e+09  9.571430206298828e-07  7.450549602508544e-06  4.901099205017090e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741739785000e+09  9.593406677246093e-07  7.450549602508544e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741740786000e+09  9.593406677246093e-07  7.450549602508544e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741741787000e+09  9.593406677246093e-07  7.450549602508544e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741742786000e+09  9.571430206298828e-07  7.450549602508544e-06  4.879122257232666e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741743786000e+09  9.571430206298828e-07  7.450549602508544e-06  4.879122257232666e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741745025000e+09  9.593406677246093e-07  7.450549602508544e-06  4.879122257232666e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741746025000e+09  9.571430206298828e-07  7.450549602508544e-06  4.923076152801514e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741747025000e+09  9.593406677246093e-07  7.428572654724120e-06  4.879122257232666e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741748025000e+09  9.571430206298828e-07  7.428572654724120e-06  4.901099205017090e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741749025000e+09  9.593406677246093e-07  7.428572654724120e-06  4.901099205017090e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741750025000e+09  9.593406677246093e-07  7.428572654724120e-06  4.901099205017090e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741751025000e+09  9.593406677246093e-07  7.450549602508544e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741752025000e+09  9.593406677246093e-07  7.450549602508544e-06  4.879122257232666e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741753025000e+09  9.593406677246093e-07  7.450549602508544e-06  4.879122257232666e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741754025000e+09  9.615384101867676e-07  7.450549602508544e-06  4.879122257232666e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741755025000e+09  9.593406677246093e-07  7.450549602508544e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741756025000e+09  9.571430206298828e-07  7.450549602508544e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741757025000e+09  9.571430206298828e-07  7.428572654724120e-06  4.879122257232666e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741758025000e+09  9.571430206298828e-07  7.428572654724120e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741759024000e+09  9.571430206298828e-07  7.450549602508544e-06  4.857141017913818e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741760024000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741764164000e+09  9.615384101867676e-07  7.428572654724120e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741765164000e+09  9.615384101867676e-07  7.428572654724120e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741766164000e+09  9.571430206298828e-07  7.428572654724120e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741767163000e+09  9.615384101867676e-07  7.450549602508544e-06  4.857141017913818e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741768230000e+09  9.593406677246093e-07  7.428572654724120e-06  4.901099205017090e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741769230000e+09  9.593406677246093e-07  7.428572654724120e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741770230000e+09  9.593406677246093e-07  7.428572654724120e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741771230000e+09  9.593406677246093e-07  7.428572654724120e-06  4.835164070129395e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741772230000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741773230000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741774229000e+09  9.593406677246093e-07  7.428572654724120e-06  4.835164070129395e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741775229000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741776229000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741777229000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741778229000e+09  9.593406677246093e-07  7.428572654724120e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741779230000e+09  9.593406677246093e-07  7.428572654724120e-06  4.835164070129395e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741780230000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741781230000e+09  9.593406677246093e-07  7.406591415405273e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741782230000e+09  9.593406677246093e-07  7.428572654724120e-06  4.879122257232666e-06  1.516481876373291e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741783230000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741784231000e+09  9.593406677246093e-07  7.428572654724120e-06  4.879122257232666e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741785231000e+09  9.593406677246093e-07  7.450549602508544e-06  4.857141017913818e-06  1.604393959045410e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741786231000e+09  9.571430206298828e-07  7.450549602508544e-06  4.857141017913818e-06  1.604393959045410e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741787231000e+09  9.571430206298828e-07  7.428572654724120e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741788231000e+09  9.549448966979981e-07  7.428572654724120e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741789232000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741790231000e+09  9.571430206298828e-07  7.428572654724120e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741791231000e+09  9.571430206298828e-07  7.406591415405273e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741792231000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741793231000e+09  9.571430206298828e-07  7.428572654724120e-06  4.835164070129395e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741794232000e+09  9.571430206298828e-07  7.428572654724120e-06  4.857141017913818e-06  1.604393959045410e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741795232000e+09  9.571430206298828e-07  7.428572654724120e-06  4.835164070129395e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741796232000e+09  9.571430206298828e-07  7.428572654724120e-06  4.857141017913818e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741797233000e+09  9.593406677246093e-07  7.428572654724120e-06  4.835164070129395e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741798234000e+09  9.571430206298828e-07  7.428572654724120e-06  4.835164070129395e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741799438000e+09  9.549448966979981e-07  7.428572654724120e-06  4.835164070129395e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741800438000e+09  9.549448966979981e-07  7.428572654724120e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741801439000e+09  9.593406677246093e-07  7.450549602508544e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741802439000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741803440000e+09  9.593406677246093e-07  7.428572654724120e-06  4.857141017913818e-06  1.538463115692139e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741804441000e+09  9.571430206298828e-07  7.428572654724120e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741805442000e+09  9.571430206298828e-07  7.428572654724120e-06  4.835164070129395e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741806442000e+09  9.571430206298828e-07  7.450549602508544e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741807442000e+09  9.571430206298828e-07  7.428572654724120e-06  4.835164070129395e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741808442000e+09  9.571430206298828e-07  7.428572654724120e-06  4.835164070129395e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741809442000e+09  9.571430206298828e-07  7.428572654724120e-06  4.835164070129395e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741810442000e+09  9.571430206298828e-07  7.428572654724120e-06  4.857141017913818e-06  1.582417011260986e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741811443000e+09  9.593406677246093e-07  7.428572654724120e-06  4.813187122344971e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741813926000e+09  9.593406677246093e-07  7.406591415405273e-06  4.813187122344971e-06  1.560440063476562e-06  0.000000000000000e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741814926000e+09  9.593406677246093e-07  7.406591415405273e-06  4.813187122344971e-06  1.582417011260986e-06  8.278388278388279e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741815926000e+09  9.593406677246093e-07  7.406591415405273e-06  4.857141017913818e-06  1.604393959045410e-06  8.278388278388279e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741816926000e+09  9.549448966979981e-07  7.406591415405273e-06  4.835164070129395e-06  1.582417011260986e-06  8.278388278388279e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741817926000e+09  9.593406677246093e-07  7.406591415405273e-06  4.791210174560547e-06  1.560440063476562e-06  8.278388278388279e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741818926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.278388278388279e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741819926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.273504273504274e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741820926000e+09  9.571430206298828e-07  7.384614467620849e-06  4.857141017913818e-06  1.582417011260986e-06  8.273504273504274e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741821926000e+09  9.593406677246093e-07  7.406591415405273e-06  4.857141017913818e-06  1.560440063476562e-06  8.273504273504274e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741822925000e+09  9.571430206298828e-07  7.406591415405273e-06  4.857141017913818e-06  1.582417011260986e-06  8.273504273504274e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741823925000e+09  9.593406677246093e-07  7.406591415405273e-06  4.879122257232666e-06  1.560440063476562e-06  8.273504273504274e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741824926000e+09  9.593406677246093e-07  7.406591415405273e-06  4.879122257232666e-06  1.560440063476562e-06  8.273504273504274e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741825926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.857141017913818e-06  1.560440063476562e-06  8.273504273504274e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741826926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.857141017913818e-06  1.560440063476562e-06  8.273504273504274e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741827926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.879122257232666e-06  1.582417011260986e-06  8.273504273504274e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741828926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.582417011260986e-06  8.273504273504274e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741829927000e+09  9.593406677246093e-07  7.406591415405273e-06  4.857141017913818e-06  1.560440063476562e-06  8.297924297924299e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741830926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.813187122344971e-06  1.582417011260986e-06  8.297924297924299e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741831926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.297924297924299e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741832926000e+09  9.527471542358398e-07  7.406591415405273e-06  4.813187122344971e-06  1.560440063476562e-06  8.297924297924299e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741833926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.813187122344971e-06  1.582417011260986e-06  8.297924297924299e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741834927000e+09  9.593406677246093e-07  7.384614467620849e-06  4.813187122344971e-06  1.582417011260986e-06  8.297924297924299e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741835927000e+09  9.593406677246093e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.297924297924299e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741836927000e+09  9.593406677246093e-07  7.406591415405273e-06  4.813187122344971e-06  1.560440063476562e-06  8.297924297924299e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741837926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.582417011260986e-06  8.307692307692308e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741838926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.813187122344971e-06  1.538463115692139e-06  8.307692307692308e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741839926000e+09  9.593406677246093e-07  7.406591415405273e-06  4.813187122344971e-06  1.538463115692139e-06  8.307692307692308e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741840926000e+09  9.549448966979981e-07  7.406591415405273e-06  4.813187122344971e-06  1.560440063476562e-06  8.307692307692308e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741841926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.813187122344971e-06  1.560440063476562e-06  8.307692307692308e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741842926000e+09  9.549448966979981e-07  7.384614467620849e-06  4.857141017913818e-06  1.560440063476562e-06  8.307692307692308e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741843926000e+09  9.549448966979981e-07  7.406591415405273e-06  4.857141017913818e-06  1.582417011260986e-06  8.317460317460318e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741844926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.857141017913818e-06  1.538463115692139e-06  8.317460317460318e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741845926000e+09  9.593406677246093e-07  7.406591415405273e-06  4.857141017913818e-06  1.538463115692139e-06  8.317460317460318e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741846925000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.317460317460318e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741847925000e+09  9.593406677246093e-07  7.406591415405273e-06  4.857141017913818e-06  1.582417011260986e-06  8.317460317460318e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741848926000e+09  9.571430206298828e-07  7.406591415405273e-06  4.857141017913818e-06  1.538463115692139e-06  8.317460317460318e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741849927000e+09  9.615384101867676e-07  7.406591415405273e-06  4.857141017913818e-06  1.560440063476562e-06  8.317460317460318e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741850928000e+09  9.615384101867676e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.317460317460318e+00  0.000000000000000e+00  0.000000000000000e+00 
 1.366741851928000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.288156288156289e+00  5.493247882810712e+00  0.000000000000000e+00 
 1.366741852929000e+09  9.527471542358398e-07  7.406591415405273e-06  4.835164070129395e-06  1.582417011260986e-06  8.288156288156289e+00  5.493247882810712e+00  0.000000000000000e+00 
 1.366741853928000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.288156288156289e+00  5.493247882810712e+00  0.000000000000000e+00 
 1.366741854929000e+09  9.571430206298828e-07  7.406591415405273e-06  4.813187122344971e-06  1.560440063476562e-06  8.288156288156289e+00  5.493247882810712e+00  0.000000000000000e+00 
 1.366741856035000e+09  9.593406677246093e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.288156288156289e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741857035000e+09  9.549448966979981e-07  7.406591415405273e-06  4.835164070129395e-06  1.582417011260986e-06  8.288156288156289e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741858036000e+09  9.593406677246093e-07  7.406591415405273e-06  4.813187122344971e-06  1.582417011260986e-06  8.288156288156289e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741859037000e+09  9.593406677246093e-07  7.384614467620849e-06  4.813187122344971e-06  1.582417011260986e-06  8.288156288156289e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741860038000e+09  9.571430206298828e-07  7.406591415405273e-06  4.813187122344971e-06  1.538463115692139e-06  8.297924297924299e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741861038000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.538463115692139e-06  8.297924297924299e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741862038000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.538463115692139e-06  8.297924297924299e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741863037000e+09  9.593406677246093e-07  7.406591415405273e-06  4.835164070129395e-06  1.538463115692139e-06  8.322344322344323e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741864037000e+09  9.549448966979981e-07  7.406591415405273e-06  4.835164070129395e-06  1.538463115692139e-06  8.322344322344323e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741865038000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.322344322344323e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741866039000e+09  9.571430206298828e-07  7.428572654724120e-06  4.857141017913818e-06  1.538463115692139e-06  8.322344322344323e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741867039000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.538463115692139e-06  8.322344322344323e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741868039000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.582417011260986e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741869040000e+09  9.549448966979981e-07  7.406591415405273e-06  4.835164070129395e-06  1.538463115692139e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741870041000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741871040000e+09  9.549448966979981e-07  7.406591415405273e-06  4.813187122344971e-06  1.560440063476562e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741872040000e+09  9.549448966979981e-07  7.406591415405273e-06  4.813187122344971e-06  1.582417011260986e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741873040000e+09  9.549448966979981e-07  7.406591415405273e-06  4.813187122344971e-06  1.582417011260986e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741874040000e+09  9.571430206298828e-07  7.428572654724120e-06  4.813187122344971e-06  1.582417011260986e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741875041000e+09  9.549448966979981e-07  7.406591415405273e-06  4.813187122344971e-06  1.582417011260986e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741876041000e+09  9.593406677246093e-07  7.406591415405273e-06  4.813187122344971e-06  1.582417011260986e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741877041000e+09  9.571430206298828e-07  7.472526550292968e-06  4.813187122344971e-06  1.604393959045410e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741878041000e+09  9.571430206298828e-07  7.494503498077392e-06  4.813187122344971e-06  1.560440063476562e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741879040000e+09  9.549448966979981e-07  7.494503498077392e-06  4.813187122344971e-06  1.560440063476562e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741880041000e+09  9.571430206298828e-07  7.538461685180663e-06  4.813187122344971e-06  1.604393959045410e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741881042000e+09  9.571430206298828e-07  7.538461685180663e-06  4.813187122344971e-06  1.560440063476562e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741882042000e+09  9.593406677246093e-07  7.516484737396240e-06  4.857141017913818e-06  1.560440063476562e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741883042000e+09  9.571430206298828e-07  7.494503498077392e-06  4.813187122344971e-06  1.538463115692139e-06  8.327228327228328e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741884042000e+09  9.571430206298828e-07  7.472526550292968e-06  4.835164070129395e-06  1.560440063476562e-06  8.341880341880342e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741885042000e+09  9.549448966979981e-07  7.516484737396240e-06  4.813187122344971e-06  1.538463115692139e-06  8.346764346764347e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741886041000e+09  9.549448966979981e-07  7.516484737396240e-06  4.813187122344971e-06  1.538463115692139e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741887041000e+09  9.549448966979981e-07  7.472526550292968e-06  4.857141017913818e-06  1.538463115692139e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741888041000e+09  9.549448966979981e-07  7.472526550292968e-06  4.857141017913818e-06  1.538463115692139e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741889041000e+09  9.527471542358398e-07  7.450549602508544e-06  4.835164070129395e-06  1.560440063476562e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741890041000e+09  9.527471542358398e-07  7.450549602508544e-06  4.835164070129395e-06  1.560440063476562e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741891041000e+09  9.549448966979981e-07  7.450549602508544e-06  4.813187122344971e-06  1.582417011260986e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741892041000e+09  9.571430206298828e-07  7.472526550292968e-06  4.813187122344971e-06  1.560440063476562e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741893042000e+09  9.571430206298828e-07  7.472526550292968e-06  4.813187122344971e-06  1.560440063476562e-06  8.341880341880342e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741894041000e+09  9.571430206298828e-07  7.472526550292968e-06  4.835164070129395e-06  1.560440063476562e-06  8.341880341880342e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741895042000e+09  9.549448966979981e-07  7.428572654724120e-06  4.835164070129395e-06  1.560440063476562e-06  8.341880341880342e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741896042000e+09  9.549448966979981e-07  7.450549602508544e-06  4.813187122344971e-06  1.582417011260986e-06  8.341880341880342e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741897042000e+09  9.549448966979981e-07  7.428572654724120e-06  4.813187122344971e-06  1.582417011260986e-06  8.341880341880342e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741898042000e+09  9.571430206298828e-07  7.450549602508544e-06  4.791210174560547e-06  1.560440063476562e-06  8.341880341880342e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741899042000e+09  9.571430206298828e-07  7.428572654724120e-06  4.769228935241699e-06  1.560440063476562e-06  8.341880341880342e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741900043000e+09  9.571430206298828e-07  7.450549602508544e-06  4.813187122344971e-06  1.582417011260986e-06  8.341880341880342e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741901043000e+09  9.571430206298828e-07  7.450549602508544e-06  4.791210174560547e-06  1.538463115692139e-06  8.356532356532357e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741902042000e+09  9.571430206298828e-07  7.472526550292968e-06  4.791210174560547e-06  1.538463115692139e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741903042000e+09  9.571430206298828e-07  7.450549602508544e-06  4.835164070129395e-06  1.538463115692139e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741904042000e+09  9.571430206298828e-07  7.450549602508544e-06  4.813187122344971e-06  1.538463115692139e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741905043000e+09  9.571430206298828e-07  7.428572654724120e-06  4.813187122344971e-06  1.538463115692139e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741906043000e+09  9.549448966979981e-07  7.428572654724120e-06  4.813187122344971e-06  1.560440063476562e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741907043000e+09  9.571430206298828e-07  7.406591415405273e-06  4.835164070129395e-06  1.538463115692139e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741908043000e+09  9.549448966979981e-07  7.406591415405273e-06  4.835164070129395e-06  1.560440063476562e-06  8.371184371184372e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741909043000e+09  9.593406677246093e-07  7.450549602508544e-06  4.813187122344971e-06  1.538463115692139e-06  8.371184371184372e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741910043000e+09  9.527471542358398e-07  7.472526550292968e-06  4.835164070129395e-06  1.538463115692139e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741911043000e+09  9.527471542358398e-07  7.472526550292968e-06  4.835164070129395e-06  1.538463115692139e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741912043000e+09  9.549448966979981e-07  7.472526550292968e-06  4.835164070129395e-06  1.582417011260986e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741913043000e+09  9.549448966979981e-07  7.450549602508544e-06  4.835164070129395e-06  1.560440063476562e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741914841000e+09  9.571430206298828e-07  7.472526550292968e-06  4.835164070129395e-06  1.560440063476562e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741915841000e+09  9.571430206298828e-07  7.472526550292968e-06  4.835164070129395e-06  1.560440063476562e-06  8.380952380952381e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741916841000e+09  9.571430206298828e-07  7.472526550292968e-06  4.813187122344971e-06  1.560440063476562e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741917840000e+09  9.571430206298828e-07  7.472526550292968e-06  4.813187122344971e-06  1.582417011260986e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741918840000e+09  9.549448966979981e-07  7.472526550292968e-06  4.835164070129395e-06  1.560440063476562e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741919840000e+09  9.549448966979981e-07  7.494503498077392e-06  4.791210174560547e-06  1.582417011260986e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741920840000e+09  9.527471542358398e-07  7.494503498077392e-06  4.813187122344971e-06  1.582417011260986e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741921840000e+09  9.527471542358398e-07  7.494503498077392e-06  4.813187122344971e-06  1.582417011260986e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741922840000e+09  9.571430206298828e-07  7.494503498077392e-06  4.835164070129395e-06  1.560440063476562e-06  8.361416361416362e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741923841000e+09  9.571430206298828e-07  7.494503498077392e-06  4.835164070129395e-06  1.538463115692139e-06  8.376068376068377e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741924841000e+09  9.549448966979981e-07  7.494503498077392e-06  4.813187122344971e-06  1.538463115692139e-06  8.376068376068377e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741925841000e+09  9.571430206298828e-07  7.472526550292968e-06  4.813187122344971e-06  1.560440063476562e-06  8.376068376068377e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741926843000e+09  9.549448966979981e-07  7.472526550292968e-06  4.813187122344971e-06  1.538463115692139e-06  8.405372405372406e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741927953000e+09  9.571430206298828e-07  7.494503498077392e-06  4.835164070129395e-06  1.560440063476562e-06  8.405372405372406e+00  5.493247882810712e+00  1.297016861219196e-02 
 1.366741928953000e+09  9.549448966979981e-07  7.472526550292968e-06  4.813187122344971e-06  1.560440063476562e-06  8.405372405372406e+00  5.493247882810712e+00  1.297016861219196e-02 
... 2287 more lines ...
  342   Monday, May 13, 2013, 15:10 Bevan MossConditioning StationStandard OperationTM3N/AHV Test All common

Bevan Moss wrote:

 A HV test was conducted yesterday on TM3. There was no target and all items were tied to common or ground. The conductivity of the water ranged from 7.1 to 7.5 Mohm. 40kV @ ~600uA without continuous sparking was achieved. The Strip tool was run but something went wrong with the export and the vacuum gauge data is missing. I have attached the file for reference and the pulled data from the achiver (only logs every 300 seconds). RGA scans were taken periodically during the test nothing unexpected was measured but we also do not know what normal looks like. The RGA application is available at http://www.thinksrs.com/downloads/soft.htm. Other items of note include significant sparks disrupts the communication between the computer and the RGA, the PNG1 gauge and its controller, and TP2 local readout screen. 

 Data has been put into and excel spread sheet

Attachment 1: TM3_40kV_22042013.xlsx
  344   Wednesday, May 15, 2013, 10:17 Bevan MossConditioning StationStandard OperationTM3No Source TrayPreliminary Results from HV testing

 Testing on TM3 without a source tray was completed on 13/05.2013. All items were tied to common and the water blocks were left open at the bottom of the module. They were left with the quick connections at the top. The vacuum was in the low 10^-6T range so this was deemed acceptable. The cooling lines withing the cage in the target hall were shorted so flow could continue. As you will see from the results a maximum of 44kV was achieved before a major spark turned the power supply off. I will be compiling all the the data so it can be compared. Also attached is the archiver data, strip tool data, and RGA data.

Attachment 1: module_hv_test_0KV.rga
Attachment 2: MODULE_hv_test_42kv.rga
Attachment 3: TM3_13052013_no_source_tray.xlsx
  348   Wednesday, May 15, 2013, 16:51 Bevan MossConditioning StationStandard OperationTM3No Source TrayRepeat of HV Test

 The HV test completed on Monday was repeated today over a much longer time period. By taking longer there was slightly less sparking but once again a maximum voltage of ~44kV was achieved. The  resistivity of the water was much higher during this run so the leakage current was less but still in the >100 uA range. The spark that occurred during the ramp up to the maximum voltage caused the "water resistivity" limit to trip. This was a feed back through the control not the actual water changing as it recovered instantaneously. 

Attachment 1: 150502013_TM3_No_Source_Tray.xlsx
  349   Wednesday, May 15, 2013, 17:32 Bevan MossConditioning StationStandard OperationTM3 TM3 in place but not connected

 To confirm that the sparking was coming from the module rather than the conditioning station TM3 was grounded and the conditioning station biased. Attached are the results. Highlights include that there was no sparking and the station was able to achieve 60kV (limited by controls from going higher). The current from the raw file has been corrected by the required factor of 5.

Attachment 1: 15052013_TM3_in_place_but_not_connected.xlsx
  350   Wednesday, May 15, 2013, 18:12 Bevan MossConditioning StationStandard OperationTM3No source trayHV test repeat

 After discussion with Friedhelm it was decided to continue trying to condition the module today before moving it tomorrow. The voltage was quickly raised until 40 kV where it was left for ~30 minutes. Sparking was minimal. It was then slowly raised to 44.3 kV it held this voltage for ~8 minutes when the current started to climb (remained below 200uA as set as a limit in previous tesing). There was also sparking at this point. This continued for ~2.5 minutes until once again the water resistivity sensor tripped again. It appears that there is a~ 44kV limit on TM3. Attached is the data. I will present all of the data to the group tomorrow showing the results of multiple testing.

 

 

Attachment 1: 15052013_TM3_HV_test_repeat.xlsx
  352   Friday, May 17, 2013, 12:02 Travis CaveConditioning StationStandard OperationTM3 module move

TM#3 with no target or source trays has been moved from the conditioning station to the NE silo.

  354   Tuesday, May 21, 2013, 11:52 Bevan MossConditioning StationStandard OperationTM3No Source TrayMay 16th Long HV conditioning

On May 16th 2013 the module was HV conditioned all day. As a result the maximum stable voltage has been increased to about 47kV (~4kV more than last test). A maximum voltage of 49kV was achieved but the module was very unstable. Attached is the data from the testing. Note that occasionally the sparking caused the PS to reset, it was turned back on and the voltage increased back to what it was (or lower) quickly.

Attachment 1: 16052013_TM3_long_HV_conditioning.xlsx
  378   Thursday, June 13, 2013, 09:18 chad fisherSouth Hot-CellRepairTM3 Source Tray/Extraction Column Removal

TM3 Rev 2 source tray/extraction column insertion into its storage was completed yesterday and it was then removed from the hot cell and put into the anteroom until June 25th when it will be moved into the vault tunnel.

 

The Box did have 10000 counts of contamination "all over" it. It has recieved inital decontamination and is down to 1000 counts.

 

 

 

 

  380   Tuesday, June 18, 2013, 14:00 chad fisherSouth Hot-CellDevelopmentTM3 Mock-up testing / water block connections

The testing of the mock-up and tooling has commenced.

Source tray mock-up has been driven into the mock-up and the first two water block connections have been made; the first with the torque limiting 
T-handle tool and the second with the torque limiting air rachet attachment. Both seem to work well, although achieving the required torque with the manipulators proved to be near the limit of the manipulator.

 

 

  381   Wednesday, June 19, 2013, 08:15 chad fisherSouth Hot-CellDevelopmentTM3 Mock up water block connections

All water block connections on the mock-up have bben achieved. It is now ready for leak checking.

The front half of the water block jig proved extremely difficult to remove.

Attachment 1: 20130619_080806[1].jpg
20130619_080806[1].jpg
Attachment 2: 20130619_080808[1].jpg
20130619_080808[1].jpg
  383   Friday, June 21, 2013, 09:26 chad fisherSouth Hot-CellDevelopmentTM3 Mock-up Leak Check Results

The Mock-up has been leak tested after the remote connection of the water blocks and is leak tight!

Thanks everybody who contributed to its success.

ELOG V2.9.2-2455