  481   Monday, September 30, 2013, 16:02 Bevan MossConditioning StationStandard OperationTM3NiO#2Vacuum

 The roughing pump for TCS was started at ~3:00 and the turbo's turned on at ~4:00. This is the minimum time for the module to pump down.

  482   Monday, September 30, 2013, 16:04 Bevan MossConditioning StationRepairTM3NiO#2Ion gauge filament replacement

 The filament on IG1 for TM3 was replaced by myself and Edi. The old filament did not appear to be damaged but the controller claimed it was. The current gauge on TM3 is a single filament, ideally it would be upgraded to a double.

  485   Wednesday, October 02, 2013, 09:40 Bevan MossConditioning StationStandard OperationTM3NiO#2HP conditioning

Yesterday the TBHT was ramped to 250 amp and the TGHT was ramped to 440 amps. Attached is the data from that run the strip tool that had this screen shot crashed but it can be recreated with the data. The TBHT ps was not reading back accurate results as such there are large steps in current or voltage or some instability for no apparent reason. In addition to this the ramping program is still not working so the ramping was a very manual process. The strip tool was left running over night, I have attached a screen shot of the the run. You will notice there are changes in vacuum that corresponds to changes in the TGHT and the TBHT voltage. Anders and myself used the archiver to plot the data with TS6 (TS3 would be better and I will have it added to the achiver), the changes in voltage and vacuum match perfectly with the compressor coming on and off. This should be investigated and possibly the temperature range of the cycling of the compressor reduced.

Attachment 1: 01102013_TM3_NiO2_TGHT_and_TBHT_ramp_up_eod.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:TGHT:RDVOL [V]	TCS:TGHT:RDCUR [A]	TCS:TBHT:RDVOL [V]	TCS:TBHT:RDCUR [A]	
10/01/2013 12:26:24.968541	                      0.000003494                      0.000008483                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:25.968221	                      0.000003516                      0.000008483                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:26.968076	                      0.000003516                      0.000008483                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:27.967994	                      0.000003494                      0.000008483                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:28.967909	                      0.000003516                      0.000008483                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:29.967723	                      0.000003472                      0.000008461                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:30.967596	                      0.000003494                      0.000008461                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:31.967466	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:32.992188	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:33.992187	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:34.992103	                      0.000003516                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:35.991944	                      0.000003516                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:36.991845	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:37.991694	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:38.992589	                      0.000003494                      0.000008505                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:39.992441	                      0.000003494                      0.000008483                      0.000007406                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:40.992335	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:42.60462	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:43.60139	                      0.000003516                      0.000008461                      0.000007406                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:44.61035	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:45.60806	                      0.000003494                      0.000008505                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:46.60702	                      0.000003494                      0.000008505                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:47.60766	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:48.61462	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:49.62355	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:50.62179	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:51.62047	                      0.000003494                      0.000008483                      0.000007428                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:52.61945	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:53.61799	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:54.62693	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:55.62785	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:56.62449	                      0.000003494                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:57.62550	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:58.63169	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:26:59.64295	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:00.63960	                      0.000003472                      0.000008461                      0.000007406                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:01.63807	                      0.000003472                      0.000008461                      0.000007406                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:02.63666	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:03.63581	                      0.000003494                      0.000008505                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:04.64414	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:05.64537	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:06.64172	                      0.000003494                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:07.64079	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:08.63970	                      0.000003516                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:09.64820	                      0.000003516                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:10.64701	                      0.000003494                      0.000008505                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:11.64536	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:12.64452	                      0.000003516                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:13.64287	                      0.000003516                      0.000008505                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:14.65215	                      0.000003494                      0.000008505                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:15.65043	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:16.64919	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:17.64797	                      0.000003494                      0.000008505                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:18.64668	                      0.000003494                      0.000008505                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:19.65546	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:20.65649	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:21.66282	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:22.66192	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:23.66088	                      0.000003494                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:24.66997	                      0.000003494                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:25.67780	                      0.000003494                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:26.67657	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:27.68761	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:28.69545	                      0.000003494                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:29.173136	                      0.000003516                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:30.173380	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:31.174041	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:32.173956	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:33.175017	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:34.175756	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:35.175519	                      0.000003472                      0.000008483                      0.000007406                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:36.175439	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:37.175269	                      0.000003494                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:38.177533	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:39.178038	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:40.177940	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:41.177878	                      0.000003494                      0.000008483                      0.000007406                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:42.177674	                      0.000003450                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:43.177534	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:44.178494	                      0.000003494                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:45.178420	                      0.000003494                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:47.556742	                      0.000003472                      0.000008483                      0.000007406                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:48.556877	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:49.556716	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:50.556647	                      0.000003450                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:51.556470	                      0.000003450                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:52.555722	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:53.556262	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:54.556119	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:55.555966	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:56.557075	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:57.556794	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:58.556582	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:27:59.556637	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:00.556339	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:01.556215	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:02.556121	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:03.555991	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:04.556884	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:05.557704	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:06.557663	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:07.557508	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:08.557363	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:09.557201	                      0.000003494                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:10.557206	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:11.556952	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:12.603135	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:13.603729	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:14.603627	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:15.604448	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:16.604357	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:17.604557	                      0.000003494                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:18.604130	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:19.604964	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:20.604817	                      0.000003472                      0.000008461                      0.000007406                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:21.605840	                      0.000003494                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:22.605655	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:23.605561	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:24.606470	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:25.606226	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:26.606108	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:27.607225	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:28.606838	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:29.607689	                      0.000003472                      0.000008461                      0.000007406                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:30.607592	                      0.000003450                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:31.607731	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:32.607319	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:33.607229	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:34.608083	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:35.607942	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:36.607853	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:37.639580	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:38.639598	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:39.639435	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:40.639309	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:41.639237	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:42.639092	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:43.642376	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:44.642881	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:45.643933	                      0.000003450                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:46.669142	                      0.000003450                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:47.669528	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:48.670348	                      0.000003450                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:49.671254	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:50.692124	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:51.692466	                      0.000003450                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:52.691865	                      0.000003450                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:53.691703	                      0.000003450                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:54.692702	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:55.692422	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:56.692317	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:57.692221	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:58.692092	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:28:59.692955	                      0.000003450                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:00.692831	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:01.692670	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:02.692596	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:03.692421	                      0.000003472                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:04.693353	                      0.000003494                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:05.694193	                      0.000003494                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:06.773807	                      0.000003450                      0.000008439                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:07.773908	                      0.000003450                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:08.773785	                      0.000003450                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:09.773707	                      0.000003472                      0.000008461                      0.000007340                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:10.773565	                      0.000003450                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:11.773425	                      0.000003450                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:12.773282	                      0.000003450                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:13.774375	                      0.000003450                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:14.775067	                      0.000003472                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:15.774905	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:16.774981	                      0.000003450                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:17.775909	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:18.775561	                      0.000003450                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:19.775556	                      0.000003450                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:20.775386	                      0.000003450                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:21.775154	                      0.000003450                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:22.775046	                      0.000003472                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:23.774939	                      0.000003450                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:24.775322	                      0.000003428                      0.000008439                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:25.775712	                      0.000003450                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:26.775518	                      0.000003450                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:27.776544	                      0.000003450                      0.000008461                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:28.776275	                      0.000003450                      0.000008483                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:29.776180	                      0.000003472                      0.000008461                      0.000007384                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:30.777108	                      0.000003450                      0.000008483                      0.000007362                           BadVal                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:31.789402	                      0.000003450                      0.000008483                      0.000007362                              0.0                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:32.789771	                      0.000003450                      0.000008483                      0.000007362                              0.0                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:33.789680	                      0.000003472                      0.000008483                      0.000007384                              0.0                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:34.789545	                      0.000003450                      0.000008483                      0.000007384                              0.0                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:35.789418	                      0.000003428                      0.000008461                      0.000007384                              0.0                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:37.442708	                      0.000003472                      0.000008461                      0.000007362                              0.0                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:38.442085	                      0.000003450                      0.000008461                      0.000007362                              0.0                           BadVal                           BadVal                           BadVal
10/01/2013 12:29:39.442135	                      0.000003450                      0.000008483                      0.000007362                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:40.441811	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:41.442707	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:42.442561	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:43.442435	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:44.443379	                      0.000003472                      0.000008461                      0.000007362                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:45.443198	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:46.444259	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:47.444924	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:48.444821	                      0.000003450                      0.000008483                      0.000007384                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:49.444709	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:50.444638	                      0.000003472                      0.000008461                      0.000007362                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:51.549284	                      0.000003472                      0.000008461                      0.000007384                              0.0                             3.36                           BadVal                           BadVal
10/01/2013 12:29:52.552322	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:29:53.552168	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:29:54.553247	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:29:55.553967	                      0.000003472                      0.000008461                      0.000007340                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:29:56.553827	                      0.000003450                      0.000008461                      0.000007406                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:29:57.553658	                      0.000003450                      0.000008417                      0.000007384                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:29:58.553540	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:29:59.554438	                      0.000003472                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:30:00.554431	                      0.000003472                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:30:01.555204	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:30:02.555036	                      0.000003450                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           BadVal
10/01/2013 12:30:03.554940	                      0.000003472                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:04.555874	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:05.555662	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:06.555571	                      0.000003472                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:07.555438	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:08.555439	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:09.556229	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:10.557048	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:11.556908	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:12.557182	                      0.000003428                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:13.557690	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:14.558563	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:15.558521	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:16.558282	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:17.558166	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:18.558067	                      0.000003428                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:19.557905	                      0.000003428                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:20.557772	                      0.000003428                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:21.557692	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:22.557585	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:23.662422	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:24.792773	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:25.793155	                      0.000003428                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:26.793121	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:27.814109	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:28.814848	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:29.816080	                      0.000003428                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:30.936335	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:31.936479	                      0.000003450                      0.000008439                      0.000007340                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:32.936542	                      0.000003428                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:33.937159	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:34.936998	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:36.28953	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:37.29782	                      0.000003450                      0.000008461                      0.000007340                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:38.101823	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:39.102451	                      0.000003450                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:40.102434	                      0.000003428                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:41.102235	                      0.000003428                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:42.102174	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:43.178823	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:44.178888	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:45.178756	                      0.000003472                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:46.178627	                      0.000003406                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:47.178529	                      0.000003428                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:48.178427	                      0.000003450                      0.000008439                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:49.178213	                      0.000003450                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:50.179230	                      0.000003450                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:51.179939	                      0.000003450                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:52.561149	                      0.000003428                      0.000008461                      0.000007340                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:53.563445	                      0.000003450                      0.000008439                      0.000007340                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:54.563591	                      0.000003450                      0.000008439                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:55.707336	                      0.000003406                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:56.732944	                      0.000003428                      0.000008439                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:57.846017	                      0.000003406                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:30:58.988827	                      0.000003428                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:00.90800	                      0.000003428                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:01.124740	                      0.000003450                      0.000008439                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:02.124607	                      0.000003428                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:03.124442	                      0.000003428                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:04.124375	                      0.000003406                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:05.124268	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:06.125092	                      0.000003450                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:07.124979	                      0.000003428                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:08.124845	                      0.000003450                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:09.124778	                      0.000003428                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:10.125618	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:11.125456	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:12.125314	                      0.000003450                      0.000008439                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:13.125188	                      0.000003450                      0.000008439                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:14.126061	                      0.000003450                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:15.126120	                      0.000003406                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:16.125873	                      0.000003450                      0.000008439                      0.000007340                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:17.125797	                      0.000003450                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:18.125584	                      0.000003450                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:19.125575	                      0.000003428                      0.000008439                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:20.126343	                      0.000003406                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:21.126184	                      0.000003406                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:22.126058	                      0.000003406                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:23.125975	                      0.000003428                      0.000008439                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:24.125801	                      0.000003428                      0.000008461                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:25.125684	                      0.000003428                      0.000008439                      0.000007384                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:26.125551	                      0.000003428                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
10/01/2013 12:31:27.126146	                      0.000003428                      0.000008461                      0.000007362                              0.0                             3.36                           0.0146                           0.8058
... 14745 more lines ...
Attachment 2: 02102013_TM3_NiO#2_HP_testing_overnight_run.JPG
02102013_TM3_NiO#2_HP_testing_overnight_run.JPG
Attachment 3: 02102013_TM3_NiO#2_HP_testing_overnight_run_archiver.JPG
02102013_TM3_NiO#2_HP_testing_overnight_run_archiver.JPG
  486   Wednesday, October 02, 2013, 13:44 Bevan MossSouth Hot-CellStandard OperationTM4 Right Coil is leaking

 Today Maico and Travis completed and electrical test to determine the right and left coil on TM4. The left coil is the negative side. From there Maico pumped on both lines for a leak test. The leak cart pumped down to its lower limits on the left line and there was no response when sprayed with helium. The right line would not pump below 2.5 x 10^-2 Torr and had a base leak rate of 3.3 x 10^-7 atm*cc/sec (this indicates a massive leak). Without spraying helium the leak cart responded and peaked at 1.9 x 10^-6 atm*cc/sec. Attached is a picture of the module indicating the line.

 

Attachment 1: tm4leak.jpg
tm4leak.jpg
  502   Tuesday, October 15, 2013, 15:34 Bevan MossITEStandard OperationTM3 Blocks moved from ITW to ITE

 Blocks 1-4 have been moved from ITW to ITE. Block 5 was moved to a storage area as it will be in the way of the harp repair. Danka took air samples and found 200 counts of alpha on the air samples but nothing on the swipes. It is recommended that resporators be worn while blocks are being lifted and lowered. She will check the monitor tomorrow to confirm it is behaving as it should.

  508   Friday, October 18, 2013, 10:17 Bevan MossITWRepair  Paddle Wheel

 Yesterday I visually inspected the paddle wheel and noticed that it was spinning freely and constant. As the signal was intermittent replaced the coil at the back of the wheel only. This does not require access to the high active water. With the coil replaced the signal looked strong. I asked operations to keep and eye on it and advise if the problem has been resolved. I also discussed with David this morning and he informed me that this is the same procedure he would have followed.

  510   Friday, October 18, 2013, 14:33 Bevan MossSouth Hot-CellStandard OperationTM4 Module move

 TM4 without a source tray was moved from the SHC to the TCS.  All went well.

  511   Friday, October 18, 2013, 14:37 Bevan MossConditioning StationStandard OperationTM4 Roughing Started

 The roughing pump has been started.

  513   Friday, October 18, 2013, 15:55 Bevan MossConditioning StationStandard OperationTM4 Turbo Pumps are on

 The Turbo pumps are now running on TCS

  514   Monday, October 21, 2013, 10:52 Bevan MossConditioning StationStandard OperationTM4 Cooling On and Electrical Connections Made

 The electrical connection have been made and cooling package was started at ~10:50am today

  515   Monday, October 21, 2013, 12:29 Bevan MossConditioning StationRepairTM4 BIAS Canbus

 There is something wrong with the BIAS canbus controller. It says that it is not alive and has timed out. I have tried unplugging it and plugging it back in but that has not resolved the problem as it normally does. I have contacted Dave Morris and am waiting to hear from him. I cannot HV test without this controller.

  518   Tuesday, October 22, 2013, 16:52 Bevan MossConditioning StationRepair  Canbus base card for BIAS

 The base card in the canbus BIAS module was determined to be faulty. Dave Morris removed a card VECC to repair the conditioning station. 

  519   Tuesday, October 22, 2013, 17:04 Bevan MossConditioning StationStandard OperationTM4 HV testing

 This afternoon TM4 with the coil removed was tested with HV. The EINZEL LENS was first tested independently while the bias canbus was being repaired. The current on the EL looked stable at 25kV for 5 minutes. At 27.5kV the current becomes unstable and occasionally sparks. This voltage was held for 30 minutes but the current did not appear to be becoming more stable. Further extended testing would be required to determine if this can be conditioned out. At this point I would suggest the EL has a HV limit near 25kV.

The BIAS and EL were then brought up to 35kV and 17.5kV respectively. This voltage was held for 35 minutes with the BAIS only sparking twice. The module can most likely hold a higher voltage but for the next 2 runs does not require more than 35kV. Further testing was not completed due to time constraints. It is recommended during the shut down that TM4 is tested to its limits. The data from the testing has been attached.

Attachment 1: 22102013_TM4_Coil_removed_EL_testing_(1).txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	
10/22/2013 13:37:21.862267	                      0.000000770                      0.000004395                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:22.872355	                      0.000000770                      0.000004395                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:23.873054	                      0.000000770                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:24.872963	                      0.000000772                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:25.873079	                      0.000000772                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:26.873705	                      0.000000768                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:27.876578	                      0.000000770                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:29.375243	                      0.000000772                      0.000004417                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:30.375246	                      0.000000772                      0.000004439                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:31.375149	                      0.000000768                      0.000004439                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:32.375021	                      0.000000768                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:33.374899	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:34.374768	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:35.375612	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:36.375526	                      0.000000768                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:37.375398	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:38.375234	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:39.375138	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:40.375023	                      0.000000772                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:41.374896	                      0.000000768                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:42.382861	                      0.000000772                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:43.389486	                      0.000000768                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:44.389518	                      0.000000770                      0.000004417                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:45.389366	                      0.000000770                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:46.389277	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:47.389116	                      0.000000770                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:48.389022	                      0.000000765                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:49.388887	                      0.000000768                      0.000004351                      0.000003010                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:50.388761	                      0.000000772                      0.000004395                      0.000003076                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:51.389631	                      0.000000770                      0.000004373                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:52.389519	                      0.000000768                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:53.389503	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:54.390277	                      0.000000770                      0.000004373                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:55.390109	                      0.000000770                      0.000004373                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:56.433276	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:57.518991	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:58.518716	                      0.000000770                      0.000004439                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:37:59.518620	                      0.000000768                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:00.518493	                      0.000000772                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:01.518366	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:02.518218	                      0.000000770                      0.000004417                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:03.518084	                      0.000000770                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:04.517962	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:05.517837	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:06.517742	                      0.000000772                      0.000004373                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:07.517620	                      0.000000768                      0.000004417                      0.000003010                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:08.517462	                      0.000000768                      0.000004417                      0.000003010                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:09.517388	                      0.000000768                      0.000004373                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:10.517236	                      0.000000770                      0.000004351                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:11.518181	                      0.000000770                      0.000004373                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:12.518953	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:13.518826	                      0.000000770                      0.000004395                      0.000003010                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:14.518758	                      0.000000772                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:15.518636	                      0.000000768                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:16.519487	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:17.519350	                      0.000000770                      0.000004395                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:18.519257	                      0.000000774                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:19.519328	                      0.000000770                      0.000004395                      0.000003032                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:20.731644	                      0.000000772                      0.000004417                      0.000003054                           BadVal                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:21.731831	                      0.000000768                      0.000004417                      0.000003054                             6.10                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:22.731710	                      0.000000770                      0.000004395                      0.000003054                             6.10                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:23.731555	                      0.000000770                      0.000004395                      0.000003032                             6.10                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:25.760555	                      0.000000770                      0.000004395                      0.000003054                             6.10                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:26.760175	                      0.000000770                      0.000004395                      0.000003054                             6.10                           BadVal                           BadVal                           BadVal
10/22/2013 13:38:27.760065	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:28.759915	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:29.759835	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:30.759664	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:31.759538	                      0.000000772                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:32.759422	                      0.000000772                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:33.759333	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:34.759215	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:35.759046	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:36.758910	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:38.267460	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:39.281825	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:40.838079	                      0.000000768                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:41.838491	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:42.839175	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:43.839077	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:44.838990	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:45.838859	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:46.839758	                      0.000000772                      0.000004373                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:47.839578	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:48.839436	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:49.839324	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:50.839153	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:51.839046	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:52.838957	                      0.000000772                      0.000004439                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:53.838832	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:54.838643	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:55.838561	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:56.838643	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:57.838361	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:58.838149	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:38:59.838017	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:00.837928	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:01.837766	                      0.000000768                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:02.837672	                      0.000000770                      0.000004373                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:03.837571	                      0.000000768                      0.000004373                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:04.837427	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:05.837619	                      0.000000772                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:06.838137	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:07.838061	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:08.837915	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:09.837804	                      0.000000765                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:10.837679	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:11.837545	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:12.837420	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:13.837268	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:14.837161	                      0.000000768                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:15.837034	                      0.000000772                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:16.837067	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:17.837757	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:18.838661	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:19.838546	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:20.838389	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:21.838289	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:22.838190	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:23.838035	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:24.837899	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:25.837761	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:26.837703	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:27.837513	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:28.837387	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:29.837306	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:30.837310	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:31.837158	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:32.837997	                      0.000000768                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:33.837790	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:34.837626	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:35.837509	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:36.837458	                      0.000000768                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:37.837295	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:38.837234	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:39.837040	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:40.836909	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:41.836799	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:42.836627	                      0.000000770                      0.000004395                      0.000002989                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:43.836540	                      0.000000772                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:44.836412	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:45.836245	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:46.836124	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:47.836171	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:48.835873	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:49.835754	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:50.835627	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:51.835524	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:52.835433	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:53.834560	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:54.835013	                      0.000000770                      0.000004395                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:55.834998	                      0.000000770                      0.000004395                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:56.834926	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:57.834780	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:58.834622	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:39:59.835523	                      0.000000768                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:00.835395	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:01.835237	                      0.000000772                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:02.835147	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:03.835023	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:04.834922	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:05.834744	                      0.000000770                      0.000004439                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:06.834646	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:07.834561	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:08.835478	                      0.000000768                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:09.835267	                      0.000000768                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:10.836453	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:11.837024	                      0.000000768                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:12.836999	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:13.836775	                      0.000000772                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:14.836652	                      0.000000770                      0.000004439                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:15.836519	                      0.000000770                      0.000004439                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:16.837395	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:17.837231	                      0.000000772                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:18.837144	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:19.837023	                      0.000000768                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:20.836945	                      0.000000770                      0.000004373                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:21.837760	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:22.837632	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:23.837573	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:24.837392	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:25.837574	                      0.000000772                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:26.838169	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:27.839066	                      0.000000768                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:28.839851	                      0.000000768                      0.000004417                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:29.840785	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:30.840634	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:31.840502	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:32.840355	                      0.000000770                      0.000004373                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:33.840251	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:34.840142	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:35.839979	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:36.839879	                      0.000000768                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:37.839787	                      0.000000770                      0.000004395                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:38.839595	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:39.839510	                      0.000000772                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:40.839534	                      0.000000770                      0.000004417                      0.000003010                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:41.839247	                      0.000000770                      0.000004395                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:42.839095	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:43.838993	                      0.000000770                      0.000004417                      0.000003054                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:44.838897	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:45.838839	                      0.000000770                      0.000004417                      0.000003032                             6.10                             0.01                           BadVal                           BadVal
10/22/2013 13:40:46.839621	                      0.000000770                      0.000004417                      0.000003054                          5001.90                             0.18                           BadVal                           BadVal
10/22/2013 13:40:47.839509	                      0.000000765                      0.000004395                      0.000003032                          5001.90                             0.18                           BadVal                           BadVal
10/22/2013 13:40:48.839389	                      0.000000770                      0.000004351                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:49.839279	                      0.000000768                      0.000004373                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:50.839135	                      0.000000770                      0.000004395                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:51.838968	                      0.000000770                      0.000004395                      0.000003054                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:52.838902	                      0.000000772                      0.000004395                      0.000003054                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:53.838753	                      0.000000772                      0.000004373                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:54.838630	                      0.000000770                      0.000004395                      0.000003054                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:55.838506	                      0.000000772                      0.000004373                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:56.838391	                      0.000000770                      0.000004373                      0.000003054                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:57.839213	                      0.000000770                      0.000004417                      0.000003054                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:58.839095	                      0.000000770                      0.000004439                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:40:59.839001	                      0.000000770                      0.000004417                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:41:00.838842	                      0.000000770                      0.000004417                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:41:01.838827	                      0.000000770                      0.000004395                      0.000003032                          5003.12                             0.18                           BadVal                           BadVal
10/22/2013 13:41:02.838593	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:03.838568	                      0.000000770                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:04.838342	                      0.000000770                      0.000004373                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:05.838244	                      0.000000772                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:06.876299	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:07.877007	                      0.000000765                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:08.876853	                      0.000000765                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:09.876746	                      0.000000768                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:10.876648	                      0.000000772                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:11.876521	                      0.000000770                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:12.876343	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:13.943583	                      0.000000772                      0.000004439                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:14.944216	                      0.000000774                      0.000004439                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:15.945081	                      0.000000768                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:16.944824	                      0.000000768                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:17.944730	                      0.000000770                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:18.944595	                      0.000000768                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:19.945612	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:20.945476	                      0.000000770                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:21.946189	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:22.946485	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:23.946234	                      0.000000770                      0.000004373                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:24.947072	                      0.000000768                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:25.947686	                      0.000000768                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:26.947607	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:27.948498	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:28.948474	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:29.948193	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:30.948120	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:31.947932	                      0.000000770                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:32.947848	                      0.000000770                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:33.947692	                      0.000000770                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:34.947592	                      0.000000770                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:35.948464	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:36.948315	                      0.000000770                      0.000004395                      0.000003010                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:37.948274	                      0.000000768                      0.000004395                      0.000003010                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:38.948093	                      0.000000768                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:39.948061	                      0.000000770                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:40.948932	                      0.000000772                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:41.948893	                      0.000000770                      0.000004373                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:42.949555	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:43.949438	                      0.000000770                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:44.949388	                      0.000000768                      0.000004373                      0.000003010                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:45.950241	                      0.000000770                      0.000004395                      0.000003010                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:46.950081	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:47.950060	                      0.000000768                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:48.949881	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:49.949720	                      0.000000768                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:50.950612	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:51.950565	                      0.000000772                      0.000004417                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:52.950352	                      0.000000768                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:53.950181	                      0.000000768                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:54.950092	                      0.000000765                      0.000004329                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:55.950988	                      0.000000772                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:56.950791	                      0.000000772                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:57.950752	                      0.000000770                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:58.950590	                      0.000000772                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:41:59.951449	                      0.000000772                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:00.952356	                      0.000000770                      0.000004417                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:01.952221	                      0.000000770                      0.000004373                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:02.952136	                      0.000000768                      0.000004373                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:03.951975	                      0.000000772                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:04.951797	                      0.000000772                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:05.952809	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:06.952566	                      0.000000770                      0.000004395                      0.000003054                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:07.953452	                      0.000000768                      0.000004395                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:08.953289	                      0.000000768                      0.000004373                      0.000003032                          5003.73                             0.18                           BadVal                           BadVal
10/22/2013 13:42:09.953196	                      0.000000768                      0.000004395                      0.000003032                          5647.66                             0.18                           BadVal                           BadVal
10/22/2013 13:42:10.954172	                      0.000000770                      0.000004373                      0.000003054                         10004.42                             0.37                           BadVal                           BadVal
10/22/2013 13:42:11.953959	                      0.000000772                      0.000004395                      0.000003054                         10004.42                             0.37                           BadVal                           BadVal
10/22/2013 13:42:12.953833	                      0.000000768                      0.000004417                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:13.953731	                      0.000000772                      0.000004417                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:14.953571	                      0.000000772                      0.000004417                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:15.954406	                      0.000000772                      0.000004395                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:16.955395	                      0.000000770                      0.000004395                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:17.955223	                      0.000000768                      0.000004373                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:18.955091	                      0.000000770                      0.000004439                      0.000003032                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:19.954934	                      0.000000770                      0.000004373                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:20.955869	                      0.000000772                      0.000004373                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:21.956711	                      0.000000770                      0.000004373                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
10/22/2013 13:42:22.956581	                      0.000000772                      0.000004373                      0.000003054                         10007.47                             0.37                           BadVal                           BadVal
... 12081 more lines ...
  520   Tuesday, October 22, 2013, 17:07 Bevan MossConditioning StationStandard Operation  services shut down

 The turbo pump, roughing pump, have been turned off and the valves for venting opened. The cooling package has also been turned off.

  538   Tuesday, November 12, 2013, 10:59 Bevan MossSouth Hot-CellStandard OperationTM2 Electrical Test

 Don Jackson and Myself completed started an electrical test on TM2. All lines passed the with OL to ground. When testing in between the lines individually there were several lines that read other than OL. It was decided to abandon the testing as there were too many "failures". The results are attached. The testing will be repeated in the conditioning station with vacuum. It is not expected that this will change anything as during a quick visual inspection it appears the lines are touching. Of note the water block jig was removed this morning by Chad.

Attachment 1: tm2_elec_test.pdf
tm2_elec_test.pdf
  539   Tuesday, November 12, 2013, 12:43 Bevan MossConditioning StationStandard OperationTM2 TM2 moved from SHC to TCS

 TM2 was moved by myself and David from the SHC to the TCS. Move went well. Curiously the fields on the module were measured higher than the previous measurement (now ~5.8mSv/hour) .

  540   Tuesday, November 12, 2013, 14:31 Bevan MossConditioning StationStandard OperationTM2 Turbo pumps started

 The turbo pumps have been started on TM2 and the conditioning station.

  541   Tuesday, November 12, 2013, 14:33 Bevan MossConditioning StationRepair  Cooling manifold returned

 The cooling manifold for the conditioning station high power water cooled lines has been returned. The cooling package can once again be operated

  544   Friday, November 15, 2013, 16:48 Bevan MossConditioning StationStandard OperationTM2 HV Testing

 High voltage testing was started on TM2 with no source tray today. The maximum stable for 1 minute voltage reached was 47.5kV but the module is still conditioning. With every step up in voltage the current goes up a large amount and slowly bleeds down. Large sparks disrupts the connection of the CANBUS to the PS which is irritating but the module can be brought up to the equivalent voltage in less than 30 seconds. Attached is a screen shot of most of the strip tool. I have also attached all of the dumped data. The module will be left under vacuum with the water running over the weekend and HV testing will continue on Monday. 

Attachment 1: TM2_conditioning_15112013.JPG
TM2_conditioning_15112013.JPG
Attachment 2: 15112013_TM2_No_source_tray_HV_test.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	TCS:DIC1:RDCOND [Mohm]	
11/15/2013 12:58:11.432659	                      0.000000497                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:12.431762	                      0.000000493                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:13.432614	                      0.000000493                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:14.432584	                      0.000000497                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:15.509248	                      0.000000495                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:16.510264	                      0.000000493                      0.000005230                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:17.510148	                      0.000000497                      0.000005230                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:18.511223	                      0.000000497                      0.000005230                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:19.511905	                      0.000000495                      0.000005230                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:20.511746	                      0.000000497                      0.000005230                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:21.511705	                      0.000000497                      0.000005230                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:22.513496	                      0.000000495                      0.000005230                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:23.699186	                      0.000000493                      0.000005230                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:24.699275	                      0.000000493                      0.000005230                      0.000003934                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:25.699104	                      0.000000493                      0.000005230                      0.000003956                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:26.698952	                      0.000000493                      0.000005230                      0.000003956                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:27.698878	                      0.000000495                      0.000005230                      0.000003934                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:28.699828	                      0.000000493                      0.000005208                      0.000003934                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:29.699628	                      0.000000497                      0.000005230                      0.000003956                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:30.699468	                      0.000000497                      0.000005230                      0.000003956                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:31.699324	                      0.000000497                      0.000005230                      0.000003934                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:32.700211	                      0.000000493                      0.000005208                      0.000003934                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:33.791202	                      0.000000495                      0.000005230                      0.000003934                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:34.790993	                      0.000000497                      0.000005230                      0.000003934                            18.31                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:35.790830	                      0.000000497                      0.000005230                      0.000003934                            18.31                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:36.790700	                      0.000000495                      0.000005230                      0.000003934                            19.45                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:37.794601	                      0.000000495                      0.000005230                      0.000003934                            19.45                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:39.967784	                      0.000000495                      0.000005252                      0.000003934                            19.45                           BadVal                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:40.968216	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:41.968066	                      0.000000495                      0.000005252                      0.000003934                            18.31                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:42.967945	                      0.000000497                      0.000005230                      0.000003912                            19.45                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:43.967797	                      0.000000497                      0.000005230                      0.000003912                            19.45                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:44.967768	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:45.968561	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:46.968400	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:47.968334	                      0.000000493                      0.000005230                      0.000003912                            19.45                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:48.969263	                      0.000000497                      0.000005230                      0.000003956                            19.45                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:49.969062	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:50.969032	                      0.000000493                      0.000005230                      0.000003956                            19.45                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:53.5747	                      0.000000493                      0.000005208                      0.000003934                            20.59                             0.36                           BadVal                           BadVal                           BadVal
11/15/2013 12:58:54.6612	                      0.000000495                      0.000005230                      0.000003934                            20.59                             0.36                             5.49                           BadVal                           BadVal
11/15/2013 12:58:55.7392	                      0.000000495                      0.000005230                      0.000003934                            20.59                             0.36                             5.49                           BadVal                           BadVal
11/15/2013 12:58:56.7300	                      0.000000495                      0.000005230                      0.000003912                            20.59                             0.36                             5.49                           BadVal                           BadVal
11/15/2013 12:58:57.7181	                      0.000000493                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                           BadVal                           BadVal
11/15/2013 12:58:58.541298	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                           BadVal                           BadVal
11/15/2013 12:58:59.541823	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:00.541718	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:01.541595	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:02.541447	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:03.542414	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:04.543237	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:05.543134	                      0.000000493                      0.000005230                      0.000003956                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:06.543098	                      0.000000493                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:07.542871	                      0.000000495                      0.000005230                      0.000003956                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:08.542735	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:09.542633	                      0.000000497                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:10.543501	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:11.543317	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:12.543243	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:13.544090	                      0.000000493                      0.000005208                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:14.543991	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:15.544912	                      0.000000493                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:16.544728	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:17.544616	                      0.000000493                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:18.544699	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:19.545382	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:20.545230	                      0.000000493                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:21.545063	                      0.000000493                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:23.49178	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:24.49863	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:25.49644	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:26.49504	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:27.49406	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:28.49319	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:29.50190	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:30.50030	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:31.50872	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:32.50780	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:33.50855	                      0.000000497                      0.000005208                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:34.51493	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:35.52409	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:36.52273	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:37.95554	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:38.95023	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:39.95900	                      0.000000495                      0.000005252                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:40.95739	                      0.000000495                      0.000005252                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:41.95643	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:42.95530	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:43.95425	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:44.96266	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:45.96110	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:46.96008	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:47.95899	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:48.95772	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:49.96644	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:50.96671	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:51.96441	                      0.000000493                      0.000005230                      0.000003956                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:52.108452	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:53.108139	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:54.108975	                      0.000000493                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:55.108896	                      0.000000497                      0.000005230                      0.000003912                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:56.108750	                      0.000000497                      0.000005208                      0.000003890                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:57.108650	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:58.108676	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 12:59:59.109396	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:00.109321	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:01.109213	                      0.000000493                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:02.109001	                      0.000000493                      0.000005252                      0.000003912                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:03.108945	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:04.109766	                      0.000000493                      0.000005252                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:05.109663	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:06.109515	                      0.000000495                      0.000005252                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:07.109400	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:08.109258	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:09.110092	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:10.111038	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:11.110850	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:12.110763	                      0.000000497                      0.000005208                      0.000003912                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:13.110637	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:14.110679	                      0.000000500                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:15.111388	                      0.000000493                      0.000005208                      0.000003934                            20.59                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:16.111290	                      0.000000493                      0.000005208                      0.000003934                            20.59                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:17.112103	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:18.111998	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:19.113023	                      0.000000493                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:20.112798	                      0.000000495                      0.000005230                      0.000003912                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:21.112597	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:22.112495	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:23.112431	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:24.113255	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:25.114199	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:26.114020	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:27.113867	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:28.113718	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:29.113592	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:30.198234	                      0.000000497                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:31.198324	                      0.000000497                      0.000005208                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:32.198224	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:33.198126	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:34.198951	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:35.198869	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:36.198766	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:37.198659	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:38.198454	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:39.199320	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:40.200236	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:41.200070	                      0.000000493                      0.000005252                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:42.276785	                      0.000000497                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:43.369848	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:44.369734	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:45.369553	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:46.369479	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:47.370294	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:48.370175	                      0.000000493                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:49.370196	                      0.000000495                      0.000005230                      0.000003912                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:50.369979	                      0.000000497                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:51.369840	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:52.369674	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:53.369549	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:54.369440	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:55.369340	                      0.000000493                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:56.374715	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:57.374086	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:58.374978	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:00:59.374794	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:00.374708	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:01.374543	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:02.374418	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:03.374342	                      0.000000493                      0.000005230                      0.000003912                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:04.375201	                      0.000000495                      0.000005252                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:05.376032	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:06.376956	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:07.376792	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:08.393286	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:09.489797	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:10.489393	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:11.489274	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:12.490141	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:13.490085	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:14.490897	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:15.490766	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:16.502129	                      0.000000493                      0.000005186                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:17.502512	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:18.646785	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:19.647284	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:20.647164	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:21.646999	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:22.646915	                      0.000000493                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:23.647987	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:24.648647	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:25.648490	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:26.742346	                      0.000000497                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:27.742301	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:28.742109	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:29.741977	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:30.741858	                      0.000000495                      0.000005186                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:31.742749	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:32.742723	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:33.742500	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:34.742394	                      0.000000497                      0.000005208                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:35.742221	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:36.742182	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:37.741980	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:38.741862	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:39.741730	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:40.741603	                      0.000000495                      0.000005252                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:41.741524	                      0.000000493                      0.000005252                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:42.741441	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:43.741227	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:44.742172	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:45.742030	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:46.741890	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:47.741850	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:48.741639	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:49.741606	                      0.000000495                      0.000005230                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:50.741348	                      0.000000495                      0.000005208                      0.000003934                            18.31                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:51.741253	                      0.000000493                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:52.741126	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:53.741182	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:54.741909	                      0.000000497                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:55.741721	                      0.000000497                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:56.741750	                      0.000000497                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:57.741516	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:58.741345	                      0.000000497                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:01:59.742237	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:00.742132	                      0.000000493                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:01.741991	                      0.000000493                      0.000005230                      0.000003934                            20.59                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:02.741924	                      0.000000495                      0.000005230                      0.000003934                            20.59                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:03.741709	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:04.741674	                      0.000000491                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:05.741491	                      0.000000491                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:06.741381	                      0.000000497                      0.000005252                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:07.741292	                      0.000000497                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:08.741124	                      0.000000495                      0.000005230                      0.000003912                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:09.741958	                      0.000000495                      0.000005230                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:10.741879	                      0.000000497                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:11.741754	                      0.000000495                      0.000005208                      0.000003934                            19.45                             0.36                             5.49                             0.01                           BadVal
11/15/2013 13:02:12.741591	                      0.000000495                      0.000005230                      0.000003934                             6.86                             0.54                             5.49                             0.01                           BadVal
11/15/2013 13:02:13.742455	                      0.000000495                      0.000005230                      0.000003912                             6.86                             0.54                             5.49                             0.01                           BadVal
11/15/2013 13:02:14.742446	                      0.000000495                      0.000005208                      0.000003934                             6.86                             0.67                             5.49                             0.01                           BadVal
11/15/2013 13:02:15.742253	                      0.000000493                      0.000005230                      0.000003934                             6.86                             0.67                             5.49                             0.01                           BadVal
11/15/2013 13:02:16.742125	                      0.000000495                      0.000005230                      0.000003934                             3.43                             0.67                             5.49                             0.01                           BadVal
11/15/2013 13:02:17.742028	                      0.000000497                      0.000005230                      0.000003934                             3.43                             0.67                             5.49                             0.01                           BadVal
11/15/2013 13:02:18.741867	                      0.000000495                      0.000005230                      0.000003912                             3.43                             0.91                             5.49                             0.01                           BadVal
11/15/2013 13:02:19.740883	                      0.000000495                      0.000005230                      0.000003912                             3.43                             0.91                             5.49                             0.01                           BadVal
11/15/2013 13:02:20.741635	                      0.000000495                      0.000005230                      0.000003934                             5.72                             0.79                             5.49                             0.01                           BadVal
11/15/2013 13:02:21.742475	                      0.000000493                      0.000005230                      0.000003934                             5.72                             0.79                             5.49                             0.01                           BadVal
11/15/2013 13:02:22.742370	                      0.000000497                      0.000005230                      0.000003934                             6.86                             0.79                             5.49                             0.01                           BadVal
11/15/2013 13:02:23.742207	                      0.000000497                      0.000005230                      0.000003934                             6.86                             0.79                             5.49                             0.01                           BadVal
11/15/2013 13:02:24.742142	                      0.000000495                      0.000005230                      0.000003934                          5009.15                            17.94                            20.14                             0.01                           BadVal
11/15/2013 13:02:25.742039	                      0.000000493                      0.000005230                      0.000003934                          5010.29                             9.46                            18.92                             0.01                           BadVal
11/15/2013 13:02:26.741832	                      0.000000493                      0.000005230                      0.000003934                          5010.29                             9.46                             9.15                             0.01                           BadVal
11/15/2013 13:02:27.741705	                      0.000000493                      0.000005230                      0.000003934                          5010.29                             8.72                             9.15                             0.01                           BadVal
11/15/2013 13:02:28.741619	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:29.741484	                      0.000000497                      0.000005230                      0.000003934                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:30.741361	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:31.741201	                      0.000000495                      0.000005208                      0.000003934                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:32.742558	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:33.743031	                      0.000000497                      0.000005208                      0.000003934                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:34.743138	                      0.000000495                      0.000005208                      0.000003934                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:35.742702	                      0.000000495                      0.000005208                      0.000003934                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:36.741960	                      0.000000495                      0.000005208                      0.000003912                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:37.742444	                      0.000000495                      0.000005208                      0.000003934                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:38.742347	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.72                             6.10                             0.01                           BadVal
11/15/2013 13:02:39.742663	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                             6.10                             0.01                           BadVal
11/15/2013 13:02:40.742106	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                             6.10                             0.01                           BadVal
11/15/2013 13:02:41.741985	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                             6.10                             0.01                           BadVal
11/15/2013 13:02:42.741905	                      0.000000495                      0.000005252                      0.000003934                          5010.29                             8.60                             6.10                             0.01                           BadVal
11/15/2013 13:02:43.741791	                      0.000000497                      0.000005230                      0.000003912                          5010.29                             8.60                             6.10                             0.01                           BadVal
11/15/2013 13:02:44.742621	                      0.000000495                      0.000005230                      0.000003956                          5010.29                             8.60                             5.49                             0.01                           BadVal
11/15/2013 13:02:45.742737	                      0.000000495                      0.000005230                      0.000003956                          5010.29                             8.60                             5.49                             0.01                           BadVal
11/15/2013 13:02:46.742322	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                             5.49                             0.01                           BadVal
11/15/2013 13:02:47.742199	                      0.000000495                      0.000005230                      0.000003912                          5010.29                             8.60                             5.49                             0.01                           BadVal
11/15/2013 13:02:48.742093	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                             1.22                             0.01                           BadVal
11/15/2013 13:02:49.743123	                      0.000000495                      0.000005230                      0.000003912                          5010.29                             8.60                             1.22                             0.01                           BadVal
11/15/2013 13:02:50.743841	                      0.000000495                      0.000005230                      0.000003912                          5010.29                             8.60                             0.61                             0.01                           BadVal
11/15/2013 13:02:51.743694	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                             0.61                             0.01                           BadVal
11/15/2013 13:02:52.743606	                      0.000000495                      0.000005230                      0.000003912                          5010.29                             8.60                             0.61                             0.01                           BadVal
11/15/2013 13:02:53.743520	                      0.000000493                      0.000005230                      0.000003912                          5010.29                             8.60                             0.61                             0.01                           BadVal
11/15/2013 13:02:54.744428	                      0.000000493                      0.000005230                      0.000003912                          5010.29                             8.60                             0.61                             0.01                           BadVal
11/15/2013 13:02:55.744320	                      0.000000493                      0.000005230                      0.000003934                          5010.29                             8.60                             0.61                             0.01                           BadVal
11/15/2013 13:02:56.744237	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                             0.61                             0.01                           BadVal
11/15/2013 13:02:57.744039	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                             0.61                             0.01                           BadVal
11/15/2013 13:02:58.743852	                      0.000000493                      0.000005230                      0.000003934                          5010.29                             8.60                          2500.03                             0.10                           BadVal
11/15/2013 13:02:59.743943	                      0.000000495                      0.000005230                      0.000003912                          5010.29                             8.60                          2500.03                             0.10                           BadVal
11/15/2013 13:03:00.744557	                      0.000000495                      0.000005230                      0.000003912                          5010.29                             8.60                          2500.03                             0.10                           BadVal
11/15/2013 13:03:01.744554	                      0.000000495                      0.000005252                      0.000003934                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:02.744313	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:05.134392	                      0.000000495                      0.000005230                      0.000003912                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:06.134923	                      0.000000495                      0.000005230                      0.000003912                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:07.134985	                      0.000000497                      0.000005230                      0.000003912                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:08.136074	                      0.000000497                      0.000005230                      0.000003934                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:09.136571	                      0.000000497                      0.000005230                      0.000003912                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:10.137545	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:11.137319	                      0.000000495                      0.000005230                      0.000003912                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:12.137158	                      0.000000495                      0.000005230                      0.000003912                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:13.137010	                      0.000000495                      0.000005208                      0.000003912                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:14.136883	                      0.000000495                      0.000005230                      0.000003934                          5010.29                             8.60                          2500.64                             0.10                           BadVal
11/15/2013 13:03:15.136867	                      0.000000495                      0.000005208                      0.000003912                          5010.29                             8.60                          2500.64                             0.10                           BadVal
... 13082 more lines ...
  545   Monday, November 18, 2013, 11:54 Bevan MossConditioning StationRepairTM2 Fault on TCS Chill

 This morning when I went to start HV conditioning CP2 and CP3 both had faults and the temperature of the water was ~27C. I reset the compressors by flipping the system reset switch. This cleared the fault and allowed the compressors to come one. To the best of my knowledge these faults happen as a result of compressor fluid pressure too low or high and temperature too low or high and lack of flow. The system cannot determine which one it was that caused the trip. The system restarted and faulted again. As I was watching this time it can be determined that the fault was the result of an over temperature event. This was the caused by the cooling fans not coming on. Which was traced to the fan VFD controllers which both read OP3 which is an Over voltage during constant speed operation. The operating manual lists these as the possible causes

The input voltage is fluctuating abnormally.

• Power network is greater than 200 kVA

• Power factor capacitor switching

• SCR switching on power network

• The drive controller is regenerating— the load causes the motor to run at a frequency higher than drive controller output frequency.

• Intermittent output phase fault

The proposed solutions are

• Install a line reactor.

• Check the input and output circuits for phase failure and rectify. 

I will continue to monitor over the next few days to see if this continues to happen. If it does I will contact ESC.