ID |
Date |
Author |
Category |
Type |
Module |
Target/Number |
Subject |
481
|
Monday, September 30, 2013, 16:02 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | NiO#2 | Vacuum |
The roughing pump for TCS was started at ~3:00 and the turbo's turned on at ~4:00. This is the minimum time for the module to pump down. |
482
|
Monday, September 30, 2013, 16:04 |
Bevan Moss | Conditioning Station | Repair | TM3 | NiO#2 | Ion gauge filament replacement |
The filament on IG1 for TM3 was replaced by myself and Edi. The old filament did not appear to be damaged but the controller claimed it was. The current gauge on TM3 is a single filament, ideally it would be upgraded to a double. |
485
|
Wednesday, October 02, 2013, 09:40 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | NiO#2 | HP conditioning |
Yesterday the TBHT was ramped to 250 amp and the TGHT was ramped to 440 amps. Attached is the data from that run the strip tool that had this screen shot crashed but it can be recreated with the data. The TBHT ps was not reading back accurate results as such there are large steps in current or voltage or some instability for no apparent reason. In addition to this the ramping program is still not working so the ramping was a very manual process. The strip tool was left running over night, I have attached a screen shot of the the run. You will notice there are changes in vacuum that corresponds to changes in the TGHT and the TBHT voltage. Anders and myself used the archiver to plot the data with TS6 (TS3 would be better and I will have it added to the achiver), the changes in voltage and vacuum match perfectly with the compressor coming on and off. This should be investigated and possibly the temperature range of the cycling of the compressor reduced. |
Attachment 1: 01102013_TM3_NiO2_TGHT_and_TBHT_ramp_up_eod.txt
|
Time TCS:IG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:TGHT:RDVOL [V] TCS:TGHT:RDCUR [A] TCS:TBHT:RDVOL [V] TCS:TBHT:RDCUR [A]
10/01/2013 12:26:24.968541 0.000003494 0.000008483 BadVal BadVal BadVal BadVal BadVal
10/01/2013 12:26:25.968221 0.000003516 0.000008483 BadVal BadVal BadVal BadVal BadVal
10/01/2013 12:26:26.968076 0.000003516 0.000008483 BadVal BadVal BadVal BadVal BadVal
10/01/2013 12:26:27.967994 0.000003494 0.000008483 BadVal BadVal BadVal BadVal BadVal
10/01/2013 12:26:28.967909 0.000003516 0.000008483 BadVal BadVal BadVal BadVal BadVal
10/01/2013 12:26:29.967723 0.000003472 0.000008461 BadVal BadVal BadVal BadVal BadVal
10/01/2013 12:26:30.967596 0.000003494 0.000008461 BadVal BadVal BadVal BadVal BadVal
10/01/2013 12:26:31.967466 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:32.992188 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:33.992187 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:34.992103 0.000003516 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:35.991944 0.000003516 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:36.991845 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:37.991694 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:38.992589 0.000003494 0.000008505 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:39.992441 0.000003494 0.000008483 0.000007406 BadVal BadVal BadVal BadVal
10/01/2013 12:26:40.992335 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:42.60462 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:43.60139 0.000003516 0.000008461 0.000007406 BadVal BadVal BadVal BadVal
10/01/2013 12:26:44.61035 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:45.60806 0.000003494 0.000008505 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:46.60702 0.000003494 0.000008505 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:47.60766 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:48.61462 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:49.62355 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:50.62179 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:51.62047 0.000003494 0.000008483 0.000007428 BadVal BadVal BadVal BadVal
10/01/2013 12:26:52.61945 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:53.61799 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:54.62693 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:55.62785 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:56.62449 0.000003494 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:26:57.62550 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:58.63169 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:26:59.64295 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:00.63960 0.000003472 0.000008461 0.000007406 BadVal BadVal BadVal BadVal
10/01/2013 12:27:01.63807 0.000003472 0.000008461 0.000007406 BadVal BadVal BadVal BadVal
10/01/2013 12:27:02.63666 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:03.63581 0.000003494 0.000008505 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:04.64414 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:05.64537 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:06.64172 0.000003494 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:07.64079 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:08.63970 0.000003516 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:09.64820 0.000003516 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:10.64701 0.000003494 0.000008505 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:11.64536 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:12.64452 0.000003516 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:13.64287 0.000003516 0.000008505 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:14.65215 0.000003494 0.000008505 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:15.65043 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:16.64919 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:17.64797 0.000003494 0.000008505 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:18.64668 0.000003494 0.000008505 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:19.65546 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:20.65649 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:21.66282 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:22.66192 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:23.66088 0.000003494 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:24.66997 0.000003494 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:25.67780 0.000003494 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:26.67657 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:27.68761 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:28.69545 0.000003494 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:29.173136 0.000003516 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:30.173380 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:31.174041 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:32.173956 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:33.175017 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:34.175756 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:35.175519 0.000003472 0.000008483 0.000007406 BadVal BadVal BadVal BadVal
10/01/2013 12:27:36.175439 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:37.175269 0.000003494 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:38.177533 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:39.178038 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:40.177940 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:41.177878 0.000003494 0.000008483 0.000007406 BadVal BadVal BadVal BadVal
10/01/2013 12:27:42.177674 0.000003450 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:43.177534 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:44.178494 0.000003494 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:45.178420 0.000003494 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:47.556742 0.000003472 0.000008483 0.000007406 BadVal BadVal BadVal BadVal
10/01/2013 12:27:48.556877 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:49.556716 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:50.556647 0.000003450 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:51.556470 0.000003450 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:52.555722 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:53.556262 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:54.556119 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:55.555966 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:27:56.557075 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:57.556794 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:58.556582 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:27:59.556637 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:00.556339 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:01.556215 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:02.556121 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:03.555991 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:04.556884 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:05.557704 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:06.557663 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:07.557508 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:08.557363 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:09.557201 0.000003494 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:10.557206 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:11.556952 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:12.603135 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:13.603729 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:14.603627 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:15.604448 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:16.604357 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:17.604557 0.000003494 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:18.604130 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:19.604964 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:20.604817 0.000003472 0.000008461 0.000007406 BadVal BadVal BadVal BadVal
10/01/2013 12:28:21.605840 0.000003494 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:22.605655 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:23.605561 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:24.606470 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:25.606226 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:26.606108 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:27.607225 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:28.606838 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:29.607689 0.000003472 0.000008461 0.000007406 BadVal BadVal BadVal BadVal
10/01/2013 12:28:30.607592 0.000003450 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:31.607731 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:32.607319 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:33.607229 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:34.608083 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:35.607942 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:36.607853 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:37.639580 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:38.639598 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:39.639435 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:40.639309 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:41.639237 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:42.639092 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:43.642376 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:44.642881 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:45.643933 0.000003450 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:46.669142 0.000003450 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:47.669528 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:48.670348 0.000003450 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:49.671254 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:50.692124 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:51.692466 0.000003450 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:52.691865 0.000003450 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:53.691703 0.000003450 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:54.692702 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:55.692422 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:28:56.692317 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:57.692221 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:58.692092 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:28:59.692955 0.000003450 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:00.692831 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:01.692670 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:02.692596 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:03.692421 0.000003472 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:04.693353 0.000003494 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:05.694193 0.000003494 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:06.773807 0.000003450 0.000008439 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:07.773908 0.000003450 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:08.773785 0.000003450 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:09.773707 0.000003472 0.000008461 0.000007340 BadVal BadVal BadVal BadVal
10/01/2013 12:29:10.773565 0.000003450 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:11.773425 0.000003450 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:12.773282 0.000003450 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:13.774375 0.000003450 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:14.775067 0.000003472 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:15.774905 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:16.774981 0.000003450 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:17.775909 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:18.775561 0.000003450 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:19.775556 0.000003450 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:20.775386 0.000003450 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:21.775154 0.000003450 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:22.775046 0.000003472 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:23.774939 0.000003450 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:24.775322 0.000003428 0.000008439 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:25.775712 0.000003450 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:26.775518 0.000003450 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:27.776544 0.000003450 0.000008461 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:28.776275 0.000003450 0.000008483 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:29.776180 0.000003472 0.000008461 0.000007384 BadVal BadVal BadVal BadVal
10/01/2013 12:29:30.777108 0.000003450 0.000008483 0.000007362 BadVal BadVal BadVal BadVal
10/01/2013 12:29:31.789402 0.000003450 0.000008483 0.000007362 0.0 BadVal BadVal BadVal
10/01/2013 12:29:32.789771 0.000003450 0.000008483 0.000007362 0.0 BadVal BadVal BadVal
10/01/2013 12:29:33.789680 0.000003472 0.000008483 0.000007384 0.0 BadVal BadVal BadVal
10/01/2013 12:29:34.789545 0.000003450 0.000008483 0.000007384 0.0 BadVal BadVal BadVal
10/01/2013 12:29:35.789418 0.000003428 0.000008461 0.000007384 0.0 BadVal BadVal BadVal
10/01/2013 12:29:37.442708 0.000003472 0.000008461 0.000007362 0.0 BadVal BadVal BadVal
10/01/2013 12:29:38.442085 0.000003450 0.000008461 0.000007362 0.0 BadVal BadVal BadVal
10/01/2013 12:29:39.442135 0.000003450 0.000008483 0.000007362 0.0 3.36 BadVal BadVal
10/01/2013 12:29:40.441811 0.000003450 0.000008461 0.000007384 0.0 3.36 BadVal BadVal
10/01/2013 12:29:41.442707 0.000003450 0.000008461 0.000007362 0.0 3.36 BadVal BadVal
10/01/2013 12:29:42.442561 0.000003450 0.000008461 0.000007384 0.0 3.36 BadVal BadVal
10/01/2013 12:29:43.442435 0.000003450 0.000008461 0.000007362 0.0 3.36 BadVal BadVal
10/01/2013 12:29:44.443379 0.000003472 0.000008461 0.000007362 0.0 3.36 BadVal BadVal
10/01/2013 12:29:45.443198 0.000003450 0.000008461 0.000007384 0.0 3.36 BadVal BadVal
10/01/2013 12:29:46.444259 0.000003450 0.000008461 0.000007384 0.0 3.36 BadVal BadVal
10/01/2013 12:29:47.444924 0.000003450 0.000008461 0.000007362 0.0 3.36 BadVal BadVal
10/01/2013 12:29:48.444821 0.000003450 0.000008483 0.000007384 0.0 3.36 BadVal BadVal
10/01/2013 12:29:49.444709 0.000003450 0.000008461 0.000007384 0.0 3.36 BadVal BadVal
10/01/2013 12:29:50.444638 0.000003472 0.000008461 0.000007362 0.0 3.36 BadVal BadVal
10/01/2013 12:29:51.549284 0.000003472 0.000008461 0.000007384 0.0 3.36 BadVal BadVal
10/01/2013 12:29:52.552322 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 BadVal
10/01/2013 12:29:53.552168 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 BadVal
10/01/2013 12:29:54.553247 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 BadVal
10/01/2013 12:29:55.553967 0.000003472 0.000008461 0.000007340 0.0 3.36 0.0146 BadVal
10/01/2013 12:29:56.553827 0.000003450 0.000008461 0.000007406 0.0 3.36 0.0146 BadVal
10/01/2013 12:29:57.553658 0.000003450 0.000008417 0.000007384 0.0 3.36 0.0146 BadVal
10/01/2013 12:29:58.553540 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 BadVal
10/01/2013 12:29:59.554438 0.000003472 0.000008461 0.000007362 0.0 3.36 0.0146 BadVal
10/01/2013 12:30:00.554431 0.000003472 0.000008461 0.000007384 0.0 3.36 0.0146 BadVal
10/01/2013 12:30:01.555204 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 BadVal
10/01/2013 12:30:02.555036 0.000003450 0.000008439 0.000007384 0.0 3.36 0.0146 BadVal
10/01/2013 12:30:03.554940 0.000003472 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:04.555874 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:05.555662 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:06.555571 0.000003472 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:07.555438 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:08.555439 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:09.556229 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:10.557048 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:11.556908 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:12.557182 0.000003428 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:13.557690 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:14.558563 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:15.558521 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:16.558282 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:17.558166 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:18.558067 0.000003428 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:19.557905 0.000003428 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:20.557772 0.000003428 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:21.557692 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:22.557585 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:23.662422 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:24.792773 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:25.793155 0.000003428 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:26.793121 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:27.814109 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:28.814848 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:29.816080 0.000003428 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:30.936335 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:31.936479 0.000003450 0.000008439 0.000007340 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:32.936542 0.000003428 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:33.937159 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:34.936998 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:36.28953 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:37.29782 0.000003450 0.000008461 0.000007340 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:38.101823 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:39.102451 0.000003450 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:40.102434 0.000003428 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:41.102235 0.000003428 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:42.102174 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:43.178823 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:44.178888 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:45.178756 0.000003472 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:46.178627 0.000003406 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:47.178529 0.000003428 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:48.178427 0.000003450 0.000008439 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:49.178213 0.000003450 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:50.179230 0.000003450 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:51.179939 0.000003450 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:52.561149 0.000003428 0.000008461 0.000007340 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:53.563445 0.000003450 0.000008439 0.000007340 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:54.563591 0.000003450 0.000008439 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:55.707336 0.000003406 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:56.732944 0.000003428 0.000008439 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:57.846017 0.000003406 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:30:58.988827 0.000003428 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:00.90800 0.000003428 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:01.124740 0.000003450 0.000008439 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:02.124607 0.000003428 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:03.124442 0.000003428 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:04.124375 0.000003406 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:05.124268 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:06.125092 0.000003450 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:07.124979 0.000003428 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:08.124845 0.000003450 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:09.124778 0.000003428 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:10.125618 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:11.125456 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:12.125314 0.000003450 0.000008439 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:13.125188 0.000003450 0.000008439 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:14.126061 0.000003450 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:15.126120 0.000003406 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:16.125873 0.000003450 0.000008439 0.000007340 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:17.125797 0.000003450 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:18.125584 0.000003450 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:19.125575 0.000003428 0.000008439 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:20.126343 0.000003406 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:21.126184 0.000003406 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:22.126058 0.000003406 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:23.125975 0.000003428 0.000008439 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:24.125801 0.000003428 0.000008461 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:25.125684 0.000003428 0.000008439 0.000007384 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:26.125551 0.000003428 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
10/01/2013 12:31:27.126146 0.000003428 0.000008461 0.000007362 0.0 3.36 0.0146 0.8058
... 14745 more lines ...
|
Attachment 2: 02102013_TM3_NiO#2_HP_testing_overnight_run.JPG
|
|
Attachment 3: 02102013_TM3_NiO#2_HP_testing_overnight_run_archiver.JPG
|
|
486
|
Wednesday, October 02, 2013, 13:44 |
Bevan Moss | South Hot-Cell | Standard Operation | TM4 | | Right Coil is leaking |
Today Maico and Travis completed and electrical test to determine the right and left coil on TM4. The left coil is the negative side. From there Maico pumped on both lines for a leak test. The leak cart pumped down to its lower limits on the left line and there was no response when sprayed with helium. The right line would not pump below 2.5 x 10^-2 Torr and had a base leak rate of 3.3 x 10^-7 atm*cc/sec (this indicates a massive leak). Without spraying helium the leak cart responded and peaked at 1.9 x 10^-6 atm*cc/sec. Attached is a picture of the module indicating the line.
|
Attachment 1: tm4leak.jpg
|
|
502
|
Tuesday, October 15, 2013, 15:34 |
Bevan Moss | ITE | Standard Operation | TM3 | | Blocks moved from ITW to ITE |
Blocks 1-4 have been moved from ITW to ITE. Block 5 was moved to a storage area as it will be in the way of the harp repair. Danka took air samples and found 200 counts of alpha on the air samples but nothing on the swipes. It is recommended that resporators be worn while blocks are being lifted and lowered. She will check the monitor tomorrow to confirm it is behaving as it should. |
508
|
Friday, October 18, 2013, 10:17 |
Bevan Moss | ITW | Repair | | | Paddle Wheel |
Yesterday I visually inspected the paddle wheel and noticed that it was spinning freely and constant. As the signal was intermittent replaced the coil at the back of the wheel only. This does not require access to the high active water. With the coil replaced the signal looked strong. I asked operations to keep and eye on it and advise if the problem has been resolved. I also discussed with David this morning and he informed me that this is the same procedure he would have followed. |
510
|
Friday, October 18, 2013, 14:33 |
Bevan Moss | South Hot-Cell | Standard Operation | TM4 | | Module move |
TM4 without a source tray was moved from the SHC to the TCS. All went well. |
511
|
Friday, October 18, 2013, 14:37 |
Bevan Moss | Conditioning Station | Standard Operation | TM4 | | Roughing Started |
The roughing pump has been started. |
513
|
Friday, October 18, 2013, 15:55 |
Bevan Moss | Conditioning Station | Standard Operation | TM4 | | Turbo Pumps are on |
The Turbo pumps are now running on TCS |
514
|
Monday, October 21, 2013, 10:52 |
Bevan Moss | Conditioning Station | Standard Operation | TM4 | | Cooling On and Electrical Connections Made |
The electrical connection have been made and cooling package was started at ~10:50am today |
515
|
Monday, October 21, 2013, 12:29 |
Bevan Moss | Conditioning Station | Repair | TM4 | | BIAS Canbus |
There is something wrong with the BIAS canbus controller. It says that it is not alive and has timed out. I have tried unplugging it and plugging it back in but that has not resolved the problem as it normally does. I have contacted Dave Morris and am waiting to hear from him. I cannot HV test without this controller. |
518
|
Tuesday, October 22, 2013, 16:52 |
Bevan Moss | Conditioning Station | Repair | | | Canbus base card for BIAS |
The base card in the canbus BIAS module was determined to be faulty. Dave Morris removed a card VECC to repair the conditioning station. |
519
|
Tuesday, October 22, 2013, 17:04 |
Bevan Moss | Conditioning Station | Standard Operation | TM4 | | HV testing |
This afternoon TM4 with the coil removed was tested with HV. The EINZEL LENS was first tested independently while the bias canbus was being repaired. The current on the EL looked stable at 25kV for 5 minutes. At 27.5kV the current becomes unstable and occasionally sparks. This voltage was held for 30 minutes but the current did not appear to be becoming more stable. Further extended testing would be required to determine if this can be conditioned out. At this point I would suggest the EL has a HV limit near 25kV.
The BIAS and EL were then brought up to 35kV and 17.5kV respectively. This voltage was held for 35 minutes with the BAIS only sparking twice. The module can most likely hold a higher voltage but for the next 2 runs does not require more than 35kV. Further testing was not completed due to time constraints. It is recommended during the shut down that TM4 is tested to its limits. The data from the testing has been attached. |
Attachment 1: 22102013_TM4_Coil_removed_EL_testing_(1).txt
|
Time TCS:IG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:EL:RDVOL [V] TCS:EL:RDCUR [mA] TCS:BIAS:RDVOL [V] TCS:BIAS:RDCUR [uA]
10/22/2013 13:37:21.862267 0.000000770 0.000004395 BadVal BadVal BadVal BadVal BadVal
10/22/2013 13:37:22.872355 0.000000770 0.000004395 BadVal BadVal BadVal BadVal BadVal
10/22/2013 13:37:23.873054 0.000000770 0.000004417 BadVal BadVal BadVal BadVal BadVal
10/22/2013 13:37:24.872963 0.000000772 0.000004417 BadVal BadVal BadVal BadVal BadVal
10/22/2013 13:37:25.873079 0.000000772 0.000004417 BadVal BadVal BadVal BadVal BadVal
10/22/2013 13:37:26.873705 0.000000768 0.000004417 BadVal BadVal BadVal BadVal BadVal
10/22/2013 13:37:27.876578 0.000000770 0.000004417 BadVal BadVal BadVal BadVal BadVal
10/22/2013 13:37:29.375243 0.000000772 0.000004417 BadVal BadVal BadVal BadVal BadVal
10/22/2013 13:37:30.375246 0.000000772 0.000004439 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:31.375149 0.000000768 0.000004439 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:32.375021 0.000000768 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:33.374899 0.000000770 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:34.374768 0.000000770 0.000004395 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:37:35.375612 0.000000770 0.000004395 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:37:36.375526 0.000000768 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:37.375398 0.000000770 0.000004395 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:37:38.375234 0.000000770 0.000004395 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:37:39.375138 0.000000770 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:40.375023 0.000000772 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:41.374896 0.000000768 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:42.382861 0.000000772 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:43.389486 0.000000768 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:44.389518 0.000000770 0.000004417 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:37:45.389366 0.000000770 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:46.389277 0.000000770 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:47.389116 0.000000770 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:48.389022 0.000000765 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:49.388887 0.000000768 0.000004351 0.000003010 BadVal BadVal BadVal BadVal
10/22/2013 13:37:50.388761 0.000000772 0.000004395 0.000003076 BadVal BadVal BadVal BadVal
10/22/2013 13:37:51.389631 0.000000770 0.000004373 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:52.389519 0.000000768 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:53.389503 0.000000770 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:54.390277 0.000000770 0.000004373 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:55.390109 0.000000770 0.000004373 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:56.433276 0.000000770 0.000004395 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:37:57.518991 0.000000770 0.000004395 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:37:58.518716 0.000000770 0.000004439 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:37:59.518620 0.000000768 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:00.518493 0.000000772 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:01.518366 0.000000770 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:02.518218 0.000000770 0.000004417 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:38:03.518084 0.000000770 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:04.517962 0.000000770 0.000004395 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:38:05.517837 0.000000770 0.000004395 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:38:06.517742 0.000000772 0.000004373 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:38:07.517620 0.000000768 0.000004417 0.000003010 BadVal BadVal BadVal BadVal
10/22/2013 13:38:08.517462 0.000000768 0.000004417 0.000003010 BadVal BadVal BadVal BadVal
10/22/2013 13:38:09.517388 0.000000768 0.000004373 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:38:10.517236 0.000000770 0.000004351 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:11.518181 0.000000770 0.000004373 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:12.518953 0.000000770 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:13.518826 0.000000770 0.000004395 0.000003010 BadVal BadVal BadVal BadVal
10/22/2013 13:38:14.518758 0.000000772 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:15.518636 0.000000768 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:16.519487 0.000000770 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:17.519350 0.000000770 0.000004395 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:18.519257 0.000000774 0.000004395 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:38:19.519328 0.000000770 0.000004395 0.000003032 BadVal BadVal BadVal BadVal
10/22/2013 13:38:20.731644 0.000000772 0.000004417 0.000003054 BadVal BadVal BadVal BadVal
10/22/2013 13:38:21.731831 0.000000768 0.000004417 0.000003054 6.10 BadVal BadVal BadVal
10/22/2013 13:38:22.731710 0.000000770 0.000004395 0.000003054 6.10 BadVal BadVal BadVal
10/22/2013 13:38:23.731555 0.000000770 0.000004395 0.000003032 6.10 BadVal BadVal BadVal
10/22/2013 13:38:25.760555 0.000000770 0.000004395 0.000003054 6.10 BadVal BadVal BadVal
10/22/2013 13:38:26.760175 0.000000770 0.000004395 0.000003054 6.10 BadVal BadVal BadVal
10/22/2013 13:38:27.760065 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:28.759915 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:29.759835 0.000000772 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:30.759664 0.000000772 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:31.759538 0.000000772 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:32.759422 0.000000772 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:38:33.759333 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:34.759215 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:35.759046 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:36.758910 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:38.267460 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:38:39.281825 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:40.838079 0.000000768 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:38:41.838491 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:38:42.839175 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:38:43.839077 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:38:44.838990 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:45.838859 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:46.839758 0.000000772 0.000004373 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:38:47.839578 0.000000770 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:48.839436 0.000000772 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:49.839324 0.000000770 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:50.839153 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:51.839046 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:38:52.838957 0.000000772 0.000004439 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:53.838832 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:38:54.838643 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:55.838561 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:56.838643 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:57.838361 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:38:58.838149 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:38:59.838017 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:00.837928 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:01.837766 0.000000768 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:02.837672 0.000000770 0.000004373 0.000003010 6.10 0.01 BadVal BadVal
10/22/2013 13:39:03.837571 0.000000768 0.000004373 0.000003010 6.10 0.01 BadVal BadVal
10/22/2013 13:39:04.837427 0.000000772 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:05.837619 0.000000772 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:06.838137 0.000000772 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:07.838061 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:08.837915 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:09.837804 0.000000765 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:10.837679 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:11.837545 0.000000772 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:12.837420 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:13.837268 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:14.837161 0.000000768 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:15.837034 0.000000772 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:16.837067 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:17.837757 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:18.838661 0.000000772 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:19.838546 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:20.838389 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:21.838289 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:22.838190 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:23.838035 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:24.837899 0.000000770 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:25.837761 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:26.837703 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:27.837513 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:28.837387 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:29.837306 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:30.837310 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:31.837158 0.000000772 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:32.837997 0.000000768 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:33.837790 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:34.837626 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:35.837509 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:36.837458 0.000000768 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:37.837295 0.000000770 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:38.837234 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:39.837040 0.000000772 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:40.836909 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:41.836799 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:42.836627 0.000000770 0.000004395 0.000002989 6.10 0.01 BadVal BadVal
10/22/2013 13:39:43.836540 0.000000772 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:44.836412 0.000000770 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:45.836245 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:46.836124 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:47.836171 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:48.835873 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:49.835754 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:50.835627 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:51.835524 0.000000772 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:52.835433 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:53.834560 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:54.835013 0.000000770 0.000004395 0.000003010 6.10 0.01 BadVal BadVal
10/22/2013 13:39:55.834998 0.000000770 0.000004395 0.000003010 6.10 0.01 BadVal BadVal
10/22/2013 13:39:56.834926 0.000000772 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:57.834780 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:39:58.834622 0.000000770 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:39:59.835523 0.000000768 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:00.835395 0.000000772 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:01.835237 0.000000772 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:02.835147 0.000000770 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:03.835023 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:04.834922 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:05.834744 0.000000770 0.000004439 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:06.834646 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:07.834561 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:08.835478 0.000000768 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:09.835267 0.000000768 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:10.836453 0.000000772 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:11.837024 0.000000768 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:12.836999 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:13.836775 0.000000772 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:14.836652 0.000000770 0.000004439 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:15.836519 0.000000770 0.000004439 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:16.837395 0.000000772 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:17.837231 0.000000772 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:18.837144 0.000000770 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:19.837023 0.000000768 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:20.836945 0.000000770 0.000004373 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:21.837760 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:22.837632 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:23.837573 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:24.837392 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:25.837574 0.000000772 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:26.838169 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:27.839066 0.000000768 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:28.839851 0.000000768 0.000004417 0.000003010 6.10 0.01 BadVal BadVal
10/22/2013 13:40:29.840785 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:30.840634 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:31.840502 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:32.840355 0.000000770 0.000004373 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:33.840251 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:34.840142 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:35.839979 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:36.839879 0.000000768 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:37.839787 0.000000770 0.000004395 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:38.839595 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:39.839510 0.000000772 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:40.839534 0.000000770 0.000004417 0.000003010 6.10 0.01 BadVal BadVal
10/22/2013 13:40:41.839247 0.000000770 0.000004395 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:42.839095 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:43.838993 0.000000770 0.000004417 0.000003054 6.10 0.01 BadVal BadVal
10/22/2013 13:40:44.838897 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:45.838839 0.000000770 0.000004417 0.000003032 6.10 0.01 BadVal BadVal
10/22/2013 13:40:46.839621 0.000000770 0.000004417 0.000003054 5001.90 0.18 BadVal BadVal
10/22/2013 13:40:47.839509 0.000000765 0.000004395 0.000003032 5001.90 0.18 BadVal BadVal
10/22/2013 13:40:48.839389 0.000000770 0.000004351 0.000003032 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:49.839279 0.000000768 0.000004373 0.000003032 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:50.839135 0.000000770 0.000004395 0.000003032 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:51.838968 0.000000770 0.000004395 0.000003054 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:52.838902 0.000000772 0.000004395 0.000003054 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:53.838753 0.000000772 0.000004373 0.000003032 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:54.838630 0.000000770 0.000004395 0.000003054 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:55.838506 0.000000772 0.000004373 0.000003032 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:56.838391 0.000000770 0.000004373 0.000003054 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:57.839213 0.000000770 0.000004417 0.000003054 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:58.839095 0.000000770 0.000004439 0.000003032 5003.12 0.18 BadVal BadVal
10/22/2013 13:40:59.839001 0.000000770 0.000004417 0.000003032 5003.12 0.18 BadVal BadVal
10/22/2013 13:41:00.838842 0.000000770 0.000004417 0.000003032 5003.12 0.18 BadVal BadVal
10/22/2013 13:41:01.838827 0.000000770 0.000004395 0.000003032 5003.12 0.18 BadVal BadVal
10/22/2013 13:41:02.838593 0.000000770 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:03.838568 0.000000770 0.000004373 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:04.838342 0.000000770 0.000004373 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:05.838244 0.000000772 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:06.876299 0.000000770 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:07.877007 0.000000765 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:08.876853 0.000000765 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:09.876746 0.000000768 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:10.876648 0.000000772 0.000004373 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:11.876521 0.000000770 0.000004417 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:12.876343 0.000000770 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:13.943583 0.000000772 0.000004439 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:14.944216 0.000000774 0.000004439 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:15.945081 0.000000768 0.000004417 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:16.944824 0.000000768 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:17.944730 0.000000770 0.000004417 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:18.944595 0.000000768 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:19.945612 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:20.945476 0.000000770 0.000004417 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:21.946189 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:22.946485 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:23.946234 0.000000770 0.000004373 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:24.947072 0.000000768 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:25.947686 0.000000768 0.000004373 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:26.947607 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:27.948498 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:28.948474 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:29.948193 0.000000770 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:30.948120 0.000000770 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:31.947932 0.000000770 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:32.947848 0.000000770 0.000004417 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:33.947692 0.000000770 0.000004417 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:34.947592 0.000000770 0.000004373 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:35.948464 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:36.948315 0.000000770 0.000004395 0.000003010 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:37.948274 0.000000768 0.000004395 0.000003010 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:38.948093 0.000000768 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:39.948061 0.000000770 0.000004417 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:40.948932 0.000000772 0.000004417 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:41.948893 0.000000770 0.000004373 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:42.949555 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:43.949438 0.000000770 0.000004373 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:44.949388 0.000000768 0.000004373 0.000003010 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:45.950241 0.000000770 0.000004395 0.000003010 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:46.950081 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:47.950060 0.000000768 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:48.949881 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:49.949720 0.000000768 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:50.950612 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:51.950565 0.000000772 0.000004417 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:52.950352 0.000000768 0.000004417 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:53.950181 0.000000768 0.000004417 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:54.950092 0.000000765 0.000004329 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:55.950988 0.000000772 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:56.950791 0.000000772 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:57.950752 0.000000770 0.000004417 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:58.950590 0.000000772 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:41:59.951449 0.000000772 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:42:00.952356 0.000000770 0.000004417 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:42:01.952221 0.000000770 0.000004373 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:42:02.952136 0.000000768 0.000004373 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:42:03.951975 0.000000772 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:42:04.951797 0.000000772 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:42:05.952809 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:42:06.952566 0.000000770 0.000004395 0.000003054 5003.73 0.18 BadVal BadVal
10/22/2013 13:42:07.953452 0.000000768 0.000004395 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:42:08.953289 0.000000768 0.000004373 0.000003032 5003.73 0.18 BadVal BadVal
10/22/2013 13:42:09.953196 0.000000768 0.000004395 0.000003032 5647.66 0.18 BadVal BadVal
10/22/2013 13:42:10.954172 0.000000770 0.000004373 0.000003054 10004.42 0.37 BadVal BadVal
10/22/2013 13:42:11.953959 0.000000772 0.000004395 0.000003054 10004.42 0.37 BadVal BadVal
10/22/2013 13:42:12.953833 0.000000768 0.000004417 0.000003054 10007.47 0.37 BadVal BadVal
10/22/2013 13:42:13.953731 0.000000772 0.000004417 0.000003054 10007.47 0.37 BadVal BadVal
10/22/2013 13:42:14.953571 0.000000772 0.000004417 0.000003054 10007.47 0.37 BadVal BadVal
10/22/2013 13:42:15.954406 0.000000772 0.000004395 0.000003054 10007.47 0.37 BadVal BadVal
10/22/2013 13:42:16.955395 0.000000770 0.000004395 0.000003054 10007.47 0.37 BadVal BadVal
10/22/2013 13:42:17.955223 0.000000768 0.000004373 0.000003054 10007.47 0.37 BadVal BadVal
10/22/2013 13:42:18.955091 0.000000770 0.000004439 0.000003032 10007.47 0.37 BadVal BadVal
10/22/2013 13:42:19.954934 0.000000770 0.000004373 0.000003054 10007.47 0.37 BadVal BadVal
10/22/2013 13:42:20.955869 0.000000772 0.000004373 0.000003054 10007.47 0.37 BadVal BadVal
10/22/2013 13:42:21.956711 0.000000770 0.000004373 0.000003054 10007.47 0.37 BadVal BadVal
10/22/2013 13:42:22.956581 0.000000772 0.000004373 0.000003054 10007.47 0.37 BadVal BadVal
... 12081 more lines ...
|
520
|
Tuesday, October 22, 2013, 17:07 |
Bevan Moss | Conditioning Station | Standard Operation | | | services shut down |
The turbo pump, roughing pump, have been turned off and the valves for venting opened. The cooling package has also been turned off. |
538
|
Tuesday, November 12, 2013, 10:59 |
Bevan Moss | South Hot-Cell | Standard Operation | TM2 | | Electrical Test |
Don Jackson and Myself completed started an electrical test on TM2. All lines passed the with OL to ground. When testing in between the lines individually there were several lines that read other than OL. It was decided to abandon the testing as there were too many "failures". The results are attached. The testing will be repeated in the conditioning station with vacuum. It is not expected that this will change anything as during a quick visual inspection it appears the lines are touching. Of note the water block jig was removed this morning by Chad. |
Attachment 1: tm2_elec_test.pdf
|
|
539
|
Tuesday, November 12, 2013, 12:43 |
Bevan Moss | Conditioning Station | Standard Operation | TM2 | | TM2 moved from SHC to TCS |
TM2 was moved by myself and David from the SHC to the TCS. Move went well. Curiously the fields on the module were measured higher than the previous measurement (now ~5.8mSv/hour) . |
540
|
Tuesday, November 12, 2013, 14:31 |
Bevan Moss | Conditioning Station | Standard Operation | TM2 | | Turbo pumps started |
The turbo pumps have been started on TM2 and the conditioning station. |
541
|
Tuesday, November 12, 2013, 14:33 |
Bevan Moss | Conditioning Station | Repair | | | Cooling manifold returned |
The cooling manifold for the conditioning station high power water cooled lines has been returned. The cooling package can once again be operated |
544
|
Friday, November 15, 2013, 16:48 |
Bevan Moss | Conditioning Station | Standard Operation | TM2 | | HV Testing |
High voltage testing was started on TM2 with no source tray today. The maximum stable for 1 minute voltage reached was 47.5kV but the module is still conditioning. With every step up in voltage the current goes up a large amount and slowly bleeds down. Large sparks disrupts the connection of the CANBUS to the PS which is irritating but the module can be brought up to the equivalent voltage in less than 30 seconds. Attached is a screen shot of most of the strip tool. I have also attached all of the dumped data. The module will be left under vacuum with the water running over the weekend and HV testing will continue on Monday. |
Attachment 1: TM2_conditioning_15112013.JPG
|
|
Attachment 2: 15112013_TM2_No_source_tray_HV_test.txt
|
Time TCS:IG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:BIAS:RDVOL [V] TCS:BIAS:RDCUR [uA] TCS:EL:RDVOL [V] TCS:EL:RDCUR [mA] TCS:DIC1:RDCOND [Mohm]
11/15/2013 12:58:11.432659 0.000000497 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:12.431762 0.000000493 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:13.432614 0.000000493 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:14.432584 0.000000497 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:15.509248 0.000000495 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:16.510264 0.000000493 0.000005230 BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:17.510148 0.000000497 0.000005230 BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:18.511223 0.000000497 0.000005230 BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:19.511905 0.000000495 0.000005230 BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:20.511746 0.000000497 0.000005230 BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:21.511705 0.000000497 0.000005230 BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:22.513496 0.000000495 0.000005230 BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:23.699186 0.000000493 0.000005230 BadVal BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:24.699275 0.000000493 0.000005230 0.000003934 BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:25.699104 0.000000493 0.000005230 0.000003956 BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:26.698952 0.000000493 0.000005230 0.000003956 BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:27.698878 0.000000495 0.000005230 0.000003934 BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:28.699828 0.000000493 0.000005208 0.000003934 BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:29.699628 0.000000497 0.000005230 0.000003956 BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:30.699468 0.000000497 0.000005230 0.000003956 BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:31.699324 0.000000497 0.000005230 0.000003934 BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:32.700211 0.000000493 0.000005208 0.000003934 BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:33.791202 0.000000495 0.000005230 0.000003934 BadVal BadVal BadVal BadVal BadVal
11/15/2013 12:58:34.790993 0.000000497 0.000005230 0.000003934 18.31 BadVal BadVal BadVal BadVal
11/15/2013 12:58:35.790830 0.000000497 0.000005230 0.000003934 18.31 BadVal BadVal BadVal BadVal
11/15/2013 12:58:36.790700 0.000000495 0.000005230 0.000003934 19.45 BadVal BadVal BadVal BadVal
11/15/2013 12:58:37.794601 0.000000495 0.000005230 0.000003934 19.45 BadVal BadVal BadVal BadVal
11/15/2013 12:58:39.967784 0.000000495 0.000005252 0.000003934 19.45 BadVal BadVal BadVal BadVal
11/15/2013 12:58:40.968216 0.000000497 0.000005230 0.000003934 18.31 0.36 BadVal BadVal BadVal
11/15/2013 12:58:41.968066 0.000000495 0.000005252 0.000003934 18.31 0.36 BadVal BadVal BadVal
11/15/2013 12:58:42.967945 0.000000497 0.000005230 0.000003912 19.45 0.36 BadVal BadVal BadVal
11/15/2013 12:58:43.967797 0.000000497 0.000005230 0.000003912 19.45 0.36 BadVal BadVal BadVal
11/15/2013 12:58:44.967768 0.000000495 0.000005230 0.000003934 19.45 0.36 BadVal BadVal BadVal
11/15/2013 12:58:45.968561 0.000000493 0.000005230 0.000003934 19.45 0.36 BadVal BadVal BadVal
11/15/2013 12:58:46.968400 0.000000493 0.000005230 0.000003934 19.45 0.36 BadVal BadVal BadVal
11/15/2013 12:58:47.968334 0.000000493 0.000005230 0.000003912 19.45 0.36 BadVal BadVal BadVal
11/15/2013 12:58:48.969263 0.000000497 0.000005230 0.000003956 19.45 0.36 BadVal BadVal BadVal
11/15/2013 12:58:49.969062 0.000000495 0.000005208 0.000003934 19.45 0.36 BadVal BadVal BadVal
11/15/2013 12:58:50.969032 0.000000493 0.000005230 0.000003956 19.45 0.36 BadVal BadVal BadVal
11/15/2013 12:58:53.5747 0.000000493 0.000005208 0.000003934 20.59 0.36 BadVal BadVal BadVal
11/15/2013 12:58:54.6612 0.000000495 0.000005230 0.000003934 20.59 0.36 5.49 BadVal BadVal
11/15/2013 12:58:55.7392 0.000000495 0.000005230 0.000003934 20.59 0.36 5.49 BadVal BadVal
11/15/2013 12:58:56.7300 0.000000495 0.000005230 0.000003912 20.59 0.36 5.49 BadVal BadVal
11/15/2013 12:58:57.7181 0.000000493 0.000005208 0.000003934 19.45 0.36 5.49 BadVal BadVal
11/15/2013 12:58:58.541298 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 BadVal BadVal
11/15/2013 12:58:59.541823 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:00.541718 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:01.541595 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:02.541447 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:03.542414 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:04.543237 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:05.543134 0.000000493 0.000005230 0.000003956 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:06.543098 0.000000493 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:07.542871 0.000000495 0.000005230 0.000003956 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:08.542735 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:09.542633 0.000000497 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:10.543501 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:11.543317 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:12.543243 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:13.544090 0.000000493 0.000005208 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:14.543991 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:15.544912 0.000000493 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:16.544728 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:17.544616 0.000000493 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:18.544699 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:19.545382 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:20.545230 0.000000493 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:21.545063 0.000000493 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:23.49178 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:24.49863 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:25.49644 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:26.49504 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:27.49406 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:28.49319 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:29.50190 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:30.50030 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:31.50872 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:32.50780 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:33.50855 0.000000497 0.000005208 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:34.51493 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:35.52409 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:36.52273 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:37.95554 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:38.95023 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:39.95900 0.000000495 0.000005252 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:40.95739 0.000000495 0.000005252 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:41.95643 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:42.95530 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:43.95425 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:44.96266 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:45.96110 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:46.96008 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:47.95899 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:48.95772 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:49.96644 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:50.96671 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:51.96441 0.000000493 0.000005230 0.000003956 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:52.108452 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:53.108139 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:54.108975 0.000000493 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:55.108896 0.000000497 0.000005230 0.000003912 18.31 0.36 5.49 0.01 BadVal
11/15/2013 12:59:56.108750 0.000000497 0.000005208 0.000003890 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:57.108650 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:58.108676 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 12:59:59.109396 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:00.109321 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:01.109213 0.000000493 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:02.109001 0.000000493 0.000005252 0.000003912 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:03.108945 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:04.109766 0.000000493 0.000005252 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:05.109663 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:06.109515 0.000000495 0.000005252 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:07.109400 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:08.109258 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:09.110092 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:10.111038 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:11.110850 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:12.110763 0.000000497 0.000005208 0.000003912 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:13.110637 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:14.110679 0.000000500 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:15.111388 0.000000493 0.000005208 0.000003934 20.59 0.36 5.49 0.01 BadVal
11/15/2013 13:00:16.111290 0.000000493 0.000005208 0.000003934 20.59 0.36 5.49 0.01 BadVal
11/15/2013 13:00:17.112103 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:18.111998 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:19.113023 0.000000493 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:20.112798 0.000000495 0.000005230 0.000003912 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:21.112597 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:22.112495 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:23.112431 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:24.113255 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:25.114199 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:26.114020 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:27.113867 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:28.113718 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:29.113592 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:30.198234 0.000000497 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:31.198324 0.000000497 0.000005208 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:32.198224 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:33.198126 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:34.198951 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:35.198869 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:36.198766 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:37.198659 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:38.198454 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:39.199320 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:40.200236 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:41.200070 0.000000493 0.000005252 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:42.276785 0.000000497 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:43.369848 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:44.369734 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:45.369553 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:46.369479 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:47.370294 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:48.370175 0.000000493 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:49.370196 0.000000495 0.000005230 0.000003912 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:00:50.369979 0.000000497 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:51.369840 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:52.369674 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:53.369549 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:54.369440 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:55.369340 0.000000493 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:56.374715 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:57.374086 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:58.374978 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:00:59.374794 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:00.374708 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:01.374543 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:02.374418 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:03.374342 0.000000493 0.000005230 0.000003912 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:04.375201 0.000000495 0.000005252 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:05.376032 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:06.376956 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:07.376792 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:08.393286 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:09.489797 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:10.489393 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:11.489274 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:12.490141 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:13.490085 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:14.490897 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:15.490766 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:16.502129 0.000000493 0.000005186 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:17.502512 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:18.646785 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:19.647284 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:20.647164 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:21.646999 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:22.646915 0.000000493 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:23.647987 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:24.648647 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:25.648490 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:26.742346 0.000000497 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:27.742301 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:28.742109 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:29.741977 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:30.741858 0.000000495 0.000005186 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:31.742749 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:32.742723 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:33.742500 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:34.742394 0.000000497 0.000005208 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:35.742221 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:36.742182 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:37.741980 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:38.741862 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:39.741730 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:40.741603 0.000000495 0.000005252 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:41.741524 0.000000493 0.000005252 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:42.741441 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:43.741227 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:44.742172 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:45.742030 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:46.741890 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:47.741850 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:48.741639 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:49.741606 0.000000495 0.000005230 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:50.741348 0.000000495 0.000005208 0.000003934 18.31 0.36 5.49 0.01 BadVal
11/15/2013 13:01:51.741253 0.000000493 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:52.741126 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:53.741182 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:54.741909 0.000000497 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:55.741721 0.000000497 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:56.741750 0.000000497 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:57.741516 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:58.741345 0.000000497 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:01:59.742237 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:00.742132 0.000000493 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:01.741991 0.000000493 0.000005230 0.000003934 20.59 0.36 5.49 0.01 BadVal
11/15/2013 13:02:02.741924 0.000000495 0.000005230 0.000003934 20.59 0.36 5.49 0.01 BadVal
11/15/2013 13:02:03.741709 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:04.741674 0.000000491 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:05.741491 0.000000491 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:06.741381 0.000000497 0.000005252 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:07.741292 0.000000497 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:08.741124 0.000000495 0.000005230 0.000003912 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:09.741958 0.000000495 0.000005230 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:10.741879 0.000000497 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:11.741754 0.000000495 0.000005208 0.000003934 19.45 0.36 5.49 0.01 BadVal
11/15/2013 13:02:12.741591 0.000000495 0.000005230 0.000003934 6.86 0.54 5.49 0.01 BadVal
11/15/2013 13:02:13.742455 0.000000495 0.000005230 0.000003912 6.86 0.54 5.49 0.01 BadVal
11/15/2013 13:02:14.742446 0.000000495 0.000005208 0.000003934 6.86 0.67 5.49 0.01 BadVal
11/15/2013 13:02:15.742253 0.000000493 0.000005230 0.000003934 6.86 0.67 5.49 0.01 BadVal
11/15/2013 13:02:16.742125 0.000000495 0.000005230 0.000003934 3.43 0.67 5.49 0.01 BadVal
11/15/2013 13:02:17.742028 0.000000497 0.000005230 0.000003934 3.43 0.67 5.49 0.01 BadVal
11/15/2013 13:02:18.741867 0.000000495 0.000005230 0.000003912 3.43 0.91 5.49 0.01 BadVal
11/15/2013 13:02:19.740883 0.000000495 0.000005230 0.000003912 3.43 0.91 5.49 0.01 BadVal
11/15/2013 13:02:20.741635 0.000000495 0.000005230 0.000003934 5.72 0.79 5.49 0.01 BadVal
11/15/2013 13:02:21.742475 0.000000493 0.000005230 0.000003934 5.72 0.79 5.49 0.01 BadVal
11/15/2013 13:02:22.742370 0.000000497 0.000005230 0.000003934 6.86 0.79 5.49 0.01 BadVal
11/15/2013 13:02:23.742207 0.000000497 0.000005230 0.000003934 6.86 0.79 5.49 0.01 BadVal
11/15/2013 13:02:24.742142 0.000000495 0.000005230 0.000003934 5009.15 17.94 20.14 0.01 BadVal
11/15/2013 13:02:25.742039 0.000000493 0.000005230 0.000003934 5010.29 9.46 18.92 0.01 BadVal
11/15/2013 13:02:26.741832 0.000000493 0.000005230 0.000003934 5010.29 9.46 9.15 0.01 BadVal
11/15/2013 13:02:27.741705 0.000000493 0.000005230 0.000003934 5010.29 8.72 9.15 0.01 BadVal
11/15/2013 13:02:28.741619 0.000000495 0.000005230 0.000003934 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:29.741484 0.000000497 0.000005230 0.000003934 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:30.741361 0.000000495 0.000005230 0.000003934 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:31.741201 0.000000495 0.000005208 0.000003934 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:32.742558 0.000000495 0.000005230 0.000003934 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:33.743031 0.000000497 0.000005208 0.000003934 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:34.743138 0.000000495 0.000005208 0.000003934 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:35.742702 0.000000495 0.000005208 0.000003934 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:36.741960 0.000000495 0.000005208 0.000003912 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:37.742444 0.000000495 0.000005208 0.000003934 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:38.742347 0.000000495 0.000005230 0.000003934 5010.29 8.72 6.10 0.01 BadVal
11/15/2013 13:02:39.742663 0.000000495 0.000005230 0.000003934 5010.29 8.60 6.10 0.01 BadVal
11/15/2013 13:02:40.742106 0.000000495 0.000005230 0.000003934 5010.29 8.60 6.10 0.01 BadVal
11/15/2013 13:02:41.741985 0.000000495 0.000005230 0.000003934 5010.29 8.60 6.10 0.01 BadVal
11/15/2013 13:02:42.741905 0.000000495 0.000005252 0.000003934 5010.29 8.60 6.10 0.01 BadVal
11/15/2013 13:02:43.741791 0.000000497 0.000005230 0.000003912 5010.29 8.60 6.10 0.01 BadVal
11/15/2013 13:02:44.742621 0.000000495 0.000005230 0.000003956 5010.29 8.60 5.49 0.01 BadVal
11/15/2013 13:02:45.742737 0.000000495 0.000005230 0.000003956 5010.29 8.60 5.49 0.01 BadVal
11/15/2013 13:02:46.742322 0.000000495 0.000005230 0.000003934 5010.29 8.60 5.49 0.01 BadVal
11/15/2013 13:02:47.742199 0.000000495 0.000005230 0.000003912 5010.29 8.60 5.49 0.01 BadVal
11/15/2013 13:02:48.742093 0.000000495 0.000005230 0.000003934 5010.29 8.60 1.22 0.01 BadVal
11/15/2013 13:02:49.743123 0.000000495 0.000005230 0.000003912 5010.29 8.60 1.22 0.01 BadVal
11/15/2013 13:02:50.743841 0.000000495 0.000005230 0.000003912 5010.29 8.60 0.61 0.01 BadVal
11/15/2013 13:02:51.743694 0.000000495 0.000005230 0.000003934 5010.29 8.60 0.61 0.01 BadVal
11/15/2013 13:02:52.743606 0.000000495 0.000005230 0.000003912 5010.29 8.60 0.61 0.01 BadVal
11/15/2013 13:02:53.743520 0.000000493 0.000005230 0.000003912 5010.29 8.60 0.61 0.01 BadVal
11/15/2013 13:02:54.744428 0.000000493 0.000005230 0.000003912 5010.29 8.60 0.61 0.01 BadVal
11/15/2013 13:02:55.744320 0.000000493 0.000005230 0.000003934 5010.29 8.60 0.61 0.01 BadVal
11/15/2013 13:02:56.744237 0.000000495 0.000005230 0.000003934 5010.29 8.60 0.61 0.01 BadVal
11/15/2013 13:02:57.744039 0.000000495 0.000005230 0.000003934 5010.29 8.60 0.61 0.01 BadVal
11/15/2013 13:02:58.743852 0.000000493 0.000005230 0.000003934 5010.29 8.60 2500.03 0.10 BadVal
11/15/2013 13:02:59.743943 0.000000495 0.000005230 0.000003912 5010.29 8.60 2500.03 0.10 BadVal
11/15/2013 13:03:00.744557 0.000000495 0.000005230 0.000003912 5010.29 8.60 2500.03 0.10 BadVal
11/15/2013 13:03:01.744554 0.000000495 0.000005252 0.000003934 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:02.744313 0.000000495 0.000005230 0.000003934 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:05.134392 0.000000495 0.000005230 0.000003912 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:06.134923 0.000000495 0.000005230 0.000003912 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:07.134985 0.000000497 0.000005230 0.000003912 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:08.136074 0.000000497 0.000005230 0.000003934 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:09.136571 0.000000497 0.000005230 0.000003912 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:10.137545 0.000000495 0.000005230 0.000003934 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:11.137319 0.000000495 0.000005230 0.000003912 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:12.137158 0.000000495 0.000005230 0.000003912 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:13.137010 0.000000495 0.000005208 0.000003912 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:14.136883 0.000000495 0.000005230 0.000003934 5010.29 8.60 2500.64 0.10 BadVal
11/15/2013 13:03:15.136867 0.000000495 0.000005208 0.000003912 5010.29 8.60 2500.64 0.10 BadVal
... 13082 more lines ...
|
545
|
Monday, November 18, 2013, 11:54 |
Bevan Moss | Conditioning Station | Repair | TM2 | | Fault on TCS Chill |
This morning when I went to start HV conditioning CP2 and CP3 both had faults and the temperature of the water was ~27C. I reset the compressors by flipping the system reset switch. This cleared the fault and allowed the compressors to come one. To the best of my knowledge these faults happen as a result of compressor fluid pressure too low or high and temperature too low or high and lack of flow. The system cannot determine which one it was that caused the trip. The system restarted and faulted again. As I was watching this time it can be determined that the fault was the result of an over temperature event. This was the caused by the cooling fans not coming on. Which was traced to the fan VFD controllers which both read OP3 which is an Over voltage during constant speed operation. The operating manual lists these as the possible causes
The input voltage is fluctuating abnormally.
• Power network is greater than 200 kVA
• Power factor capacitor switching
• SCR switching on power network
• The drive controller is regenerating— the load causes the motor to run at a frequency higher than drive controller output frequency.
• Intermittent output phase fault
The proposed solutions are
• Install a line reactor.
• Check the input and output circuits for phase failure and rectify.
I will continue to monitor over the next few days to see if this continues to happen. If it does I will contact ESC. |