Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC, Page 112 of 141  Not logged in ELOG logo
ID Date Author Categorydown Type Module Target/Number Subject
  546   Monday, November 18, 2013, 16:42 Bevan MossConditioning StationStandard OperationTM2 HV Testing

 The Glory of TM2 continues 100V at a time. Today I brought the module to 46kV and left it there for 1 hour. During this time there was only 1 spark. I then continues at up to 53kV. At this voltage the canbus continues to be temperamental when the module sparks. The module is still conditioning and I will continue more tomorrow. Attached is the dumped data and a screen shot of the conditioning from 46kV to 53kV.

Attachment 1: the_glory_of_TM2.JPG
the_glory_of_TM2.JPG
Attachment 2: 18112013_TM2_No_source_tray_HV_Test.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
11/18/2013 11:56:33.67635	                      0.000000350                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:34.66886	                      0.000000350                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:35.66751	                      0.000000350                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:36.67660	                      0.000000352                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:37.67534	                      0.000000352                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:38.68405	                      0.000000352                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:39.68261	                      0.000000352                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:40.68163	                      0.000000350                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:41.68032	                      0.000000350                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:42.67903	                      0.000000354                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:43.68805	                      0.000000350                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:44.68623	                      0.000000350                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:45.68500	                      0.000000350                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:46.69372	                      0.000000350                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:47.69322	                      0.000000352                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:48.69129	                      0.000000352                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:49.69014	                      0.000000352                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:50.68910	                      0.000000350                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:51.68802	                      0.000000352                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:52.68661	                      0.000000350                      0.000003780                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:53.68525	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:54.68443	                      0.000000354                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:55.68299	                      0.000000354                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:56.69356	                      0.000000350                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:57.69988	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:58.69998	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:59.70818	                      0.000000352                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:00.70672	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:01.71518	                      0.000000354                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:02.71393	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:03.72305	                      0.000000352                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:04.72168	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:05.71991	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:06.72879	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:07.72774	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:08.72786	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:09.73521	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:10.73360	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:11.73271	                      0.000000348                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:12.73140	                      0.000000352                      0.000003802                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:13.72987	                      0.000000352                      0.000003802                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:14.72862	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:15.73998	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:16.74679	                      0.000000352                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:17.74555	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:18.74357	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:19.74415	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:20.75099	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:21.76009	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:22.75889	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:23.75773	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:24.167647	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:25.167497	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:26.168548	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:27.168249	                      0.000000354                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:28.168091	                      0.000000354                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:29.168174	                      0.000000348                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:30.167873	                      0.000000357                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:31.168824	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:32.168589	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:33.168490	                      0.000000352                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:34.168368	                      0.000000348                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:35.169260	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:36.170079	                      0.000000350                      0.000003758                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:37.169962	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:38.169833	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:39.169741	                      0.000000348                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:40.169577	                      0.000000348                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:41.170683	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:42.171478	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:43.171240	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:44.171080	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:45.171080	                      0.000000352                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:46.171861	                      0.000000354                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:47.171901	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:48.173683	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:49.173532	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:50.173355	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:51.174221	                      0.000000350                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:52.174097	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:53.173980	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:54.173846	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:55.173701	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:56.174624	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:57.174550	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:58.175484	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:59.175364	                      0.000000352                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:00.176142	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:01.176991	                      0.000000348                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:02.176907	                      0.000000350                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:03.176736	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:04.176560	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:05.176444	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:06.176439	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:07.176466	                      0.000000352                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:08.176115	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:09.175970	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:10.175854	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:11.176710	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:12.176587	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:13.176518	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:14.177305	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:15.178256	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:16.178161	                      0.000000346                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:17.177934	                      0.000000346                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:18.177862	                      0.000000348                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:19.177767	                      0.000000350                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:20.178771	                      0.000000352                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:21.179458	                      0.000000348                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:22.180299	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:23.180173	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:24.180086	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:25.180011	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:26.180879	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:27.180711	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:28.180607	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:29.180448	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:30.180303	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:31.181202	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:32.181076	                      0.000000346                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:33.180951	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:34.180824	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:35.180722	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:36.180621	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:37.180619	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:38.181373	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:39.181195	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:40.181042	                      0.000000348                      0.000003736                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:41.181989	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:42.181796	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:43.181704	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:44.182677	                      0.000000350                      0.000003758                      0.000002087                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:45.182451	                      0.000000346                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:46.183316	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:48.803335	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:49.803216	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:50.802868	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:51.802603	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:52.803455	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:53.803339	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:54.803283	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:55.804102	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:56.803969	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:57.803933	                      0.000000348                      0.000003758                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:58.803707	                      0.000000348                      0.000003758                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:59.803667	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:00.803690	                      0.000000348                      0.000003758                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:01.803354	                      0.000000350                      0.000003758                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:02.803204	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:03.803102	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:04.802982	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:05.803883	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:06.803746	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:07.803569	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:08.803499	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:09.803404	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:10.803237	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:11.803090	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:12.802976	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:13.802824	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:14.802723	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:15.802654	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:16.802447	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:17.802315	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:18.802355	                      0.000000348                      0.000003736                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:19.802084	                      0.000000348                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:20.802934	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:21.802850	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:22.802712	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:23.802672	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:24.802472	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:25.802310	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:26.802213	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:28.87230	                      0.000000350                      0.000003736                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:29.86904	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:30.86799	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:31.87780	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:32.87546	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:33.87451	                      0.000000350                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:34.87271	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:35.87150	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:36.88072	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:37.87900	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:38.87899	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:39.87677	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:40.88567	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:41.89421	                      0.000000346                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:42.89294	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:43.89145	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:44.89053	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:45.88930	                      0.000000350                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:46.89854	                      0.000000352                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:47.89750	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:48.89545	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:49.90415	                      0.000000350                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:50.90300	                      0.000000348                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:51.91305	                      0.000000350                      0.000003736                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:52.91017	                      0.000000350                      0.000003736                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:53.90976	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:54.91865	                      0.000000350                      0.000003758                      0.000002087                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:55.92687	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:56.93563	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:57.93420	                      0.000000346                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:58.93286	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:59.93135	                      0.000000348                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:00.93026	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:01.93957	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:02.93759	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:03.93679	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:04.93605	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:05.93414	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:06.94302	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:07.94146	                      0.000000348                      0.000003736                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:08.94029	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:09.93914	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:10.93783	                      0.000000348                      0.000003736                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:11.93656	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:12.93579	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:13.93443	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:14.93255	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:15.93164	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:16.94024	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:17.93919	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:18.93782	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:19.93656	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:20.93610	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:21.94365	                      0.000000348                      0.000003736                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:22.94271	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:23.94121	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:24.94077	                      0.000000348                      0.000003802                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:25.101301	                      0.000000348                      0.000003736                      0.000002000                            29.75                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:26.101770	                      0.000000352                      0.000003758                      0.000002043                            28.61                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:27.628314	                      0.000000348                      0.000003758                      0.000002043                            28.61                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:28.628508	                      0.000000352                      0.000003758                      0.000002021                            28.61                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:29.629329	                      0.000000350                      0.000003758                      0.000002043                            28.61                             0.48                           BadVal                           BadVal
11/18/2013 12:00:30.629181	                      0.000000350                      0.000003758                      0.000002043                            29.75                             0.48                           BadVal                           BadVal
11/18/2013 12:00:31.630128	                      0.000000348                      0.000003736                      0.000002043                            29.75                             0.48                           BadVal                           BadVal
11/18/2013 12:00:32.629945	                      0.000000348                      0.000003758                      0.000002043                            28.61                             0.48                           BadVal                           BadVal
11/18/2013 12:00:33.629793	                      0.000000348                      0.000003736                      0.000002043                            28.61                             0.48                           BadVal                           BadVal
11/18/2013 12:00:34.658234	                      0.000000348                      0.000003758                      0.000002043                            28.61                             0.48                           BadVal                           BadVal
11/18/2013 12:00:35.657546	                      0.000000348                      0.000003758                      0.000002043                            28.61                             0.48                           BadVal                           BadVal
11/18/2013 12:00:36.657419	                      0.000000348                      0.000003758                      0.000002087                            27.46                             0.48                             6.10                           BadVal
11/18/2013 12:00:37.657311	                      0.000000348                      0.000003736                      0.000002043                            27.46                             0.48                             6.10                           BadVal
11/18/2013 12:00:38.657194	                      0.000000348                      0.000003736                      0.000002043                            29.75                             0.48                             6.10                           BadVal
11/18/2013 12:00:39.658139	                      0.000000348                      0.000003736                      0.000002043                            29.75                             0.48                             6.10                           BadVal
11/18/2013 12:00:42.44788	                      0.000000348                      0.000003758                      0.000002021                            28.61                             0.48                             6.10                           BadVal
11/18/2013 12:00:43.44671	                      0.000000348                      0.000003758                      0.000002021                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:44.44499	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             5.49                             0.01
11/18/2013 12:00:45.44528	                      0.000000350                      0.000003758                      0.000002065                            28.61                             0.48                             5.49                             0.01
11/18/2013 12:00:46.44300	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:47.44150	                      0.000000346                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:48.43366	                      0.000000346                      0.000003758                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:00:49.44059	                      0.000000348                      0.000003758                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:00:50.43894	                      0.000000350                      0.000003758                      0.000002043                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:51.43674	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:52.44636	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:53.44585	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:54.45302	                      0.000000352                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:55.44355	                      0.000000352                      0.000003758                      0.000002043                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:56.44002	                      0.000000352                      0.000003780                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:00:57.44147	                      0.000000352                      0.000003736                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:00:58.44820	                      0.000000348                      0.000003758                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:00:59.44598	                      0.000000348                      0.000003758                      0.000002021                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:00.44519	                      0.000000350                      0.000003758                      0.000002021                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:01.44421	                      0.000000348                      0.000003758                      0.000002000                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:02.44217	                      0.000000348                      0.000003758                      0.000002000                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:03.44128	                      0.000000348                      0.000003736                      0.000002043                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:04.43981	                      0.000000348                      0.000003736                      0.000002021                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:05.43875	                      0.000000348                      0.000003736                      0.000002043                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:06.43730	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:01:07.43676	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:01:08.43483	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:01:10.527029	                      0.000000350                      0.000003758                      0.000002043                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:11.526244	                      0.000000348                      0.000003758                      0.000002043                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:12.526954	                      0.000000348                      0.000003736                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:13.526789	                      0.000000348                      0.000003736                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:01:14.526783	                      0.000000348                      0.000003758                      0.000002043                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:01:15.526585	                      0.000000350                      0.000003736                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:17.268629	                      0.000000350                      0.000003758                      0.000002043                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:18.269323	                      0.000000348                      0.000003758                      0.000002065                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:19.269066	                      0.000000348                      0.000003758                      0.000002043                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:20.269024	                      0.000000348                      0.000003758                      0.000002043                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:21.268809	                      0.000000348                      0.000003758                      0.000002065                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:22.268839	                      0.000000350                      0.000003736                      0.000002043                             8.01                             0.36                             6.10                             0.01
11/18/2013 12:01:23.269588	                      0.000000350                      0.000003758                      0.000002065                             8.01                             0.36                             6.10                             0.01
11/18/2013 12:01:24.269513	                      0.000000348                      0.000003758                      0.000002043                             8.01                             0.73                             6.10                             0.01
11/18/2013 12:01:25.269349	                      0.000000346                      0.000003736                      0.000002021                             8.01                             0.73                             6.10                             0.01
11/18/2013 12:01:26.269482	                      0.000000346                      0.000003758                      0.000002043                             5.72                             0.61                             6.10                             0.01
11/18/2013 12:01:27.270296	                      0.000000350                      0.000003758                      0.000002043                             5.72                             0.61                             6.10                             0.01
11/18/2013 12:01:28.269961	                      0.000000350                      0.000003736                      0.000002043                            10.29                             0.85                             6.10                             0.01
11/18/2013 12:01:29.269871	                      0.000000348                      0.000003758                      0.000002043                            10.29                             0.85                             6.10                             0.01
11/18/2013 12:01:30.269726	                      0.000000350                      0.000003736                      0.000002043                             8.01                             0.85                             6.10                             0.01
11/18/2013 12:01:31.369724	                      0.000000348                      0.000003780                      0.000002043                             8.01                             0.85                             6.10                             0.01
11/18/2013 12:01:32.369423	                      0.000000348                      0.000003758                      0.000002065                            10.29                             0.73                             6.10                             0.01
11/18/2013 12:01:33.370375	                      0.000000350                      0.000003758                      0.000002065                            10.29                             0.73                             6.10                             0.01
11/18/2013 12:01:34.370213	                      0.000000348                      0.000003780                      0.000002043                            11.44                             0.73                             6.10                             0.01
11/18/2013 12:01:35.370088	                      0.000000350                      0.000003780                      0.000002043                            11.44                             0.73                             6.10                             0.01
11/18/2013 12:01:36.369921	                      0.000000350                      0.000003758                      0.000002043                             4.57                             0.85                             6.10                             0.01
11/18/2013 12:01:37.585188	                      0.000000348                      0.000003758                      0.000002043                             4.57                             0.85                             6.10                             0.01
... 15829 more lines ...
  547   Monday, November 18, 2013, 16:44 Bevan MossConditioning StationStandard Operation  Testing of cooling package

 I have tested all of the compressors for TCS. All are operational and cycled as they should. 

  550   Tuesday, November 19, 2013, 16:55 Bevan MossConditioning StationStandard OperationTM2 HV conditioning

 HV conditioning of TM2 continued today. At ~53.5kV the module started to spark externally to the HV cover. This is the first time the cover has been tested to this high of a voltage due to the limitations of the modules. As such for the conditioning station to achieve 60kV while keeping the target hall open of personnel the cover and cage will need to be modified. To continue with HV testing of TM2 the cover was removed and the target hall locked out as per the procedure covered in Document 70039 "ISAC Conditioning Station: First Lock-Out and High-Voltage "ON". With the cover off the module was able to achieve ~56.7kV without the Einzel lens on. Eliminate the Einzel lens as a potential source of sparking it was brought to 25kV while the module continued conditioning. Maximum voltage achieve under this configuration was 57.1kV. Increments are now 50V steps. The Canbus continues to be very sensitive to any sparking and is slowing the process down considerably. It does however appear that the module is continuing to condition. I will continue tomorrow after the module moves to attempt to reach 60kV and hold it for 1 hour.

Attachment 1: external_sparking.JPG
external_sparking.JPG
Attachment 2: 19112013_HV_conditioning_TM2.JPG
19112013_HV_conditioning_TM2.JPG
Attachment 3: 19112013_TM2_No_source_tray_HV_Test_no_cover.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
11/19/2013 14:05:53.354722	                      0.000000302                      0.000003362                      0.000001516                            11.44                             0.18                             4.88                             0.03
11/19/2013 14:05:54.354616	                      0.000000300                      0.000003362                      0.000001516                            18.31                             0.18                             4.88                             0.03
11/19/2013 14:05:55.354491	                      0.000000304                      0.000003340                      0.000001516                            18.31                             0.18                             4.88                             0.03
11/19/2013 14:05:56.355471	                      0.000000304                      0.000003340                      0.000001538                            18.31                             0.18                             4.88                             0.03
11/19/2013 14:05:57.355260	                      0.000000304                      0.000003362                      0.000001538                            21.74                             0.18                             4.88                             0.03
11/19/2013 14:05:58.356309	                      0.000000304                      0.000003362                      0.000001516                            21.74                             0.18                             4.88                             0.03
11/19/2013 14:05:59.355939	                      0.000000304                      0.000003362                      0.000001516                            25.17                             0.30                             4.88                             0.03
11/19/2013 14:06:00.356012	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.30                             4.88                             0.03
11/19/2013 14:06:01.356728	                      0.000000300                      0.000003362                      0.000001538                            26.32                             0.30                             4.88                             0.03
11/19/2013 14:06:02.356720	                      0.000000304                      0.000003362                      0.000001516                            26.32                             0.30                             4.88                             0.03
11/19/2013 14:06:03.356444	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:04.357380	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:05.357218	                      0.000000302                      0.000003362                      0.000001538                            26.32                             0.30                             5.49                             0.03
11/19/2013 14:06:06.358329	                      0.000000306                      0.000003362                      0.000001538                            26.32                             0.30                             5.49                             0.03
11/19/2013 14:06:07.359140	                      0.000000302                      0.000003384                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:08.358814	                      0.000000302                      0.000003340                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:09.358730	                      0.000000306                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:10.358605	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:11.359545	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:12.359312	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:13.359243	                      0.000000304                      0.000003384                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:14.359103	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:15.359040	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:16.359868	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:17.359724	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:18.359599	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:19.359585	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:20.359298	                      0.000000304                      0.000003384                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:21.360304	                      0.000000304                      0.000003384                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:22.360120	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:23.359987	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:24.359901	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:25.359840	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:26.360642	                      0.000000300                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:27.360471	                      0.000000300                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:28.359710	                      0.000000306                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:29.360203	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:30.360083	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:31.360917	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:32.360825	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:33.360728	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:34.360551	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:35.360556	                      0.000000304                      0.000003340                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:36.361435	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:37.361170	                      0.000000302                      0.000003384                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:38.361078	                      0.000000306                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:39.360960	                      0.000000304                      0.000003362                      0.000001560                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:40.360827	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:41.361763	                      0.000000302                      0.000003362                      0.000001560                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:42.362590	                      0.000000302                      0.000003362                      0.000001560                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:43.362450	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:44.362283	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:45.363190	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:46.364029	                      0.000000302                      0.000003362                      0.000001494                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:47.363963	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:48.363929	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:49.364676	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:50.364535	                      0.000000304                      0.000003340                      0.000001560                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:51.365463	                      0.000000300                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:52.366307	                      0.000000300                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:53.366193	                      0.000000308                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:54.366069	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:55.365938	                      0.000000306                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:56.366809	                      0.000000304                      0.000003362                      0.000001516                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:06:57.366654	                      0.000000304                      0.000003362                      0.000001538                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:06:58.367523	                      0.000000304                      0.000003384                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:59.367430	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:00.367278	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:01.367220	                      0.000000306                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:02.367054	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:03.366900	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:04.366837	                      0.000000304                      0.000003340                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:05.366830	                      0.000000304                      0.000003362                      0.000001560                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:06.367680	                      0.000000300                      0.000003340                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:07.367422	                      0.000000302                      0.000003362                      0.000001494                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:08.367307	                      0.000000308                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:09.367180	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:10.367078	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:11.368047	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:12.367770	                      0.000000302                      0.000003362                      0.000001560                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:13.367637	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:14.367544	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:15.367429	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:16.368326	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:17.368176	                      0.000000306                      0.000003362                      0.000001516                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:18.368039	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:19.367933	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:20.367835	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:21.368721	                      0.000000300                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:22.368549	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:23.368413	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:24.368292	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:25.368197	                      0.000000304                      0.000003362                      0.000001538                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:26.369153	                      0.000000304                      0.000003362                      0.000001538                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:27.369877	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:28.369786	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:29.369767	                      0.000000306                      0.000003340                      0.000001538                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:30.369531	                      0.000000302                      0.000003362                      0.000001516                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:31.370442	                      0.000000304                      0.000003362                      0.000001560                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:32.370291	                      0.000000302                      0.000003362                      0.000001538                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:33.370168	                      0.000000304                      0.000003362                      0.000001560                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:34.369996	                      0.000000304                      0.000003362                      0.000001560                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:35.369937	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:36.370838	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:37.370668	                      0.000000302                      0.000003362                      0.000001560                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:38.370749	                      0.000000304                      0.000003362                      0.000001582                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:39.371415	                      0.000000302                      0.000003384                      0.000001560                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:40.371286	                      0.000000304                      0.000003384                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:41.372115	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:42.371999	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:43.371914	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:44.371842	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:45.371657	                      0.000000302                      0.000003362                      0.000001560                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:46.372526	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:47.372407	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:48.372325	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:49.372151	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:50.373021	                      0.000000302                      0.000003362                      0.000001560                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:51.373956	                      0.000000304                      0.000003362                      0.000001560                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:07:52.373746	                      0.000000304                      0.000003384                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:07:53.373706	                      0.000000304                      0.000003362                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:54.373541	                      0.000000302                      0.000003362                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:55.373384	                      0.000000308                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:56.373439	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:57.373107	                      0.000000304                      0.000003362                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:58.373036	                      0.000000306                      0.000003384                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:59.372863	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:00.372736	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:01.373696	                      0.000000306                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:02.373648	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:03.374534	                      0.000000300                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:04.375263	                      0.000000308                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:05.376101	                      0.000000308                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:06.377066	                      0.000000297                      0.000003362                      0.000001494                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:07.376910	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:08.376768	                      0.000000304                      0.000003318                      0.000001560                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:09.376642	                      0.000000306                      0.000003362                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:10.376520	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:11.376582	                      0.000000300                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:12.376266	                      0.000000300                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:13.376238	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:14.375983	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:15.375886	                      0.000000304                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:16.375820	                      0.000000306                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:17.375626	                      0.000000304                      0.000003340                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:18.375507	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:19.375369	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:20.376380	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:21.377197	                      0.000000304                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:22.377109	                      0.000000304                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:23.376905	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:24.376781	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:25.377666	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:26.377670	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:27.377464	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:28.378245	                      0.000000300                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:29.378131	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:30.378152	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:31.377926	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:32.377773	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:33.377608	                      0.000000304                      0.000003340                      0.000001560                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:34.378551	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:35.378336	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:36.379229	                      0.000000304                      0.000003340                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:37.379143	                      0.000000306                      0.000003340                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:38.380035	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:39.379852	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:40.379853	                      0.000000304                      0.000003340                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:41.380667	                      0.000000300                      0.000003362                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:42.380496	                      0.000000302                      0.000003340                      0.000001582                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:43.381497	                      0.000000306                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:44.382284	                      0.000000306                      0.000003340                      0.000001494                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:45.382081	                      0.000000306                      0.000003362                      0.000001494                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:46.382969	                      0.000000306                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:47.382888	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:48.382765	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:49.382582	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:50.382483	                      0.000000306                      0.000003362                      0.000001494                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:51.383390	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:52.383236	                      0.000000306                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:53.383142	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:54.382977	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:55.383033	                      0.000000302                      0.000003362                      0.000001560                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:56.383746	                      0.000000302                      0.000003384                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:57.383610	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:58.384517	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:59.384360	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:00.384233	                      0.000000306                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:01.384098	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:02.384008	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:03.383841	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:04.384838	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:05.384849	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:06.385552	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:07.385371	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:08.385188	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:09.385098	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:10.384964	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:11.385810	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:12.385870	                      0.000000306                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:13.386593	                      0.000000304                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:14.386563	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:15.386310	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:16.387331	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:17.387108	                      0.000000300                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:18.386975	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:19.386848	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:20.386684	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:21.387583	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:22.387469	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:23.387339	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:24.387222	                      0.000000304                      0.000003362                      0.000001560                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:25.387167	                      0.000000306                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:26.388077	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:27.387859	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:28.387670	                      0.000000304                      0.000003384                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:29.387547	                      0.000000304                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:30.387462	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:31.388291	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:32.388300	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:33.388040	                      0.000000302                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:34.387967	                      0.000000308                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:35.387846	                      0.000000304                      0.000003318                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:36.388795	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:37.389717	                      0.000000302                      0.000003384                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:38.389408	                      0.000000302                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:39.389291	                      0.000000302                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:40.389397	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:41.390033	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:42.389915	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:43.389825	                      0.000000306                      0.000003384                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:09:44.389697	                      0.000000304                      0.000003384                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:09:45.389571	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:46.390485	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:47.391343	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:48.391159	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:49.391072	                      0.000000302                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:50.390947	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:51.391775	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:52.391202	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:53.391826	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:54.392406	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:55.392281	                      0.000000304                      0.000003384                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:56.393178	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:57.393028	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:58.392904	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:59.392947	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:00.392649	                      0.000000302                      0.000003384                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:01.393587	                      0.000000302                      0.000003340                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:02.393437	                      0.000000300                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:03.393427	                      0.000000304                      0.000003384                      0.000001494                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:04.393216	                      0.000000302                      0.000003362                      0.000001494                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:05.393073	                      0.000000302                      0.000003362                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:06.392979	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:07.392808	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:08.392747	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:09.393600	                      0.000000302                      0.000003340                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:10.393431	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:11.394321	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:12.394255	                      0.000000302                      0.000003362                      0.000001582                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:13.394061	                      0.000000306                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:14.393935	                      0.000000304                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:15.394815	                      0.000000304                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:16.395754	                      0.000000304                      0.000003362                      0.000001494                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:17.395575	                      0.000000302                      0.000003318                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:18.395428	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:19.395326	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:20.396197	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:21.397060	                      0.000000304                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:22.397959	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:23.397760	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:24.397660	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:25.397555	                      0.000000306                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:26.397473	                      0.000000304                      0.000003362                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:27.397292	                      0.000000304                      0.000003362                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:28.397275	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:29.397064	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:30.397950	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:31.398916	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:32.398700	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:33.398565	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:34.398475	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:35.399271	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:36.400292	                      0.000000300                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:37.400283	                      0.000000300                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:38.399877	                      0.000000300                      0.000003362                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:39.400813	                      0.000000302                      0.000003362                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:40.401650	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:41.402517	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:42.403427	                      0.000000302                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:43.403303	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:44.403147	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:45.403017	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:46.403927	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:47.403779	                      0.000000306                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:48.404762	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:49.405527	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:50.405406	                      0.000000300                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:51.405266	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
... 9169 more lines ...
Attachment 4: 19112013_TM2_No_source_tray_HV_Test.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
11/19/2013 10:41:01.318511	                      0.000000302                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:02.317614	                      0.000000304                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:03.317465	                      0.000000304                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:04.317355	                      0.000000304                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:05.402487	                      0.000000304                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:06.403328	                      0.000000302                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:07.403004	                      0.000000302                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:08.402906	                      0.000000302                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:09.402698	                      0.000000302                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:10.402606	                      0.000000304                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:11.403668	                      0.000000304                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:12.404343	                      0.000000302                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:13.404485	                      0.000000306                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:14.404091	                      0.000000300                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:15.404261	                      0.000000302                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:16.404970	                      0.000000300                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:17.405939	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:18.405596	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:19.405470	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:20.405591	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:21.405361	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:22.405110	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:23.404945	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:24.405004	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:25.404869	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:26.405664	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:27.405452	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:28.405690	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:29.406257	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:30.406107	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:31.407176	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:32.406962	                      0.000000302                      0.000003362                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:33.407750	                      0.000000302                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:34.407588	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:35.407461	                      0.000000306                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:36.407365	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:37.407206	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:38.407144	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:39.406973	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:40.406863	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:41.407851	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:42.408741	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:43.408455	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:44.408363	                      0.000000300                      0.000003340                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:45.408507	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:46.409102	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:47.408996	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:48.409016	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:49.408903	                      0.000000304                      0.000003384                      0.000001516                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:50.408651	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:51.409561	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:52.409366	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:53.671050	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:54.675348	                      0.000000306                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:55.675949	                      0.000000300                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:56.676845	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:57.676692	                      0.000000300                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:58.676230	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:59.677764	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:00.677259	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:01.678167	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:02.679007	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:03.678882	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:04.679802	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:05.679736	                      0.000000300                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:06.680510	                      0.000000300                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:07.680434	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:08.680253	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:09.680303	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:10.680002	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:11.706336	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:12.706772	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:13.706749	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:14.707652	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:15.708502	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:16.709291	                      0.000000306                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:17.709139	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:18.709013	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:19.708875	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:20.708773	                      0.000000300                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:21.708676	                      0.000000300                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:22.708491	                      0.000000300                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:23.708396	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:24.708237	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:25.708129	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:26.709068	                      0.000000306                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:27.709892	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:28.709771	                      0.000000302                      0.000003362                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:29.709605	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:30.709518	                      0.000000300                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:31.710437	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:32.710268	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:33.710139	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:34.710975	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:35.710972	                      0.000000308                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:36.711931	                      0.000000302                      0.000003340                      0.000001604                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:37.769372	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:38.769499	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:39.769426	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:40.768586	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:41.769111	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:42.769018	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:43.768903	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:44.768752	                      0.000000300                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:45.768651	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:46.769518	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:47.769367	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:48.769247	                      0.000000306                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:49.769168	                      0.000000306                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:50.769023	                      0.000000302                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:51.769882	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:52.769737	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:53.851442	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:54.851454	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:55.851327	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:56.852247	                      0.000000304                      0.000003340                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:57.852146	                      0.000000302                      0.000003340                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:58.851996	                      0.000000300                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:59.851955	                      0.000000300                      0.000003362                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:00.851730	                      0.000000304                      0.000003362                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:01.851594	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:02.851462	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:03.851516	                      0.000000300                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:04.851223	                      0.000000302                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:05.851091	                      0.000000300                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:06.850946	                      0.000000300                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:07.850844	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:08.851722	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:10.796013	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:11.796351	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:12.796332	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:13.796099	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:14.795971	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:15.795875	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:16.795690	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:17.795627	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:18.796444	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:19.796344	                      0.000000300                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:20.796217	                      0.000000300                      0.000003384                      0.000001560                            26.32                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:21.797113	                      0.000000302                      0.000003362                      0.000001560                            26.32                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:22.796966	                      0.000000304                      0.000003362                      0.000001560                            26.32                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:23.796853	                      0.000000302                      0.000003384                      0.000001560                            26.32                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:24.797719	                      0.000000304                      0.000003384                      0.000001560                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:25.797602	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:26.797843	                      0.000000302                      0.000003384                      0.000001538                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:27.797315	                      0.000000302                      0.000003384                      0.000001582                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:28.797410	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:29.797095	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:31.261550	                      0.000000304                      0.000003384                      0.000001560                            26.32                             0.48                           BadVal                           BadVal
11/19/2013 10:43:32.261753	                      0.000000304                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                           BadVal
11/19/2013 10:43:33.261681	                      0.000000304                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                           BadVal
11/19/2013 10:43:34.261527	                      0.000000302                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                           BadVal
11/19/2013 10:43:35.261401	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                           BadVal
11/19/2013 10:43:36.261291	                      0.000000304                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:37.261143	                      0.000000304                      0.000003384                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:38.357263	                      0.000000306                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:39.357863	                      0.000000306                      0.000003384                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:40.357775	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:41.358683	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:42.358279	                      0.000000304                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:43.358382	                      0.000000304                      0.000003384                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:44.358287	                      0.000000302                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:45.358241	                      0.000000302                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:46.359014	                      0.000000304                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:47.358900	                      0.000000302                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:48.553700	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:49.617444	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:50.617485	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:51.617351	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:52.617213	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:53.618083	                      0.000000302                      0.000003362                      0.000001604                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:54.693871	                      0.000000302                      0.000003362                      0.000001604                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:55.693812	                      0.000000302                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:56.693704	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:57.693643	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:58.693461	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:59.693350	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:00.693181	                      0.000000302                      0.000003384                      0.000001604                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:01.694099	                      0.000000300                      0.000003362                      0.000001604                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:02.694989	                      0.000000302                      0.000003362                      0.000001604                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:03.694798	                      0.000000302                      0.000003384                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:04.695712	                      0.000000304                      0.000003384                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:05.695611	                      0.000000306                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:06.696507	                      0.000000304                      0.000003384                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:07.697388	                      0.000000306                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:08.697233	                      0.000000300                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:09.697084	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:10.697082	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:11.697791	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:12.698710	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:13.698611	                      0.000000306                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:14.698625	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:15.698313	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:16.699228	                      0.000000304                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:17.699088	                      0.000000302                      0.000003384                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:18.700241	                      0.000000302                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:19.699985	                      0.000000304                      0.000003362                      0.000001516                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:20.699919	                      0.000000302                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:21.700749	                      0.000000304                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:22.700485	                      0.000000302                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:23.700313	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:24.700161	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:25.700124	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:26.826729	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:27.826774	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:28.826673	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:29.826713	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:30.826398	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:31.826314	                      0.000000304                      0.000003362                      0.000001538                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:32.826263	                      0.000000304                      0.000003362                      0.000001538                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:33.826027	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:34.825896	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:35.825862	                      0.000000304                      0.000003384                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:36.825771	                      0.000000300                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:37.826602	                      0.000000302                      0.000003384                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:38.826434	                      0.000000300                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:39.826342	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:40.826153	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:41.826047	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:42.825889	                      0.000000304                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:43.825806	                      0.000000300                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:44.825678	                      0.000000302                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:45.825560	                      0.000000300                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:46.825450	                      0.000000304                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:47.825323	                      0.000000302                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:48.825136	                      0.000000302                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:49.825003	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:50.825965	                      0.000000304                      0.000003384                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:51.825800	                      0.000000302                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:52.825783	                      0.000000300                      0.000003340                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:53.826612	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:54.826401	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:57.57542	                      0.000000304                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:58.57013	                      0.000000306                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:59.56879	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:00.146237	                      0.000000300                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:01.146631	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:02.146917	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:03.146342	                      0.000000304                      0.000003384                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:45:04.146247	                      0.000000304                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:45:05.146129	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:06.146037	                      0.000000300                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:07.146918	                      0.000000302                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:45:08.146753	                      0.000000304                      0.000003384                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:45:09.146640	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:10.146497	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:11.146466	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:12.147338	                      0.000000300                      0.000003362                      0.000001582                             4.57                             0.85                             6.10                             0.01
11/19/2013 10:45:13.147084	                      0.000000300                      0.000003384                      0.000001560                             4.57                             0.85                             6.10                             0.01
11/19/2013 10:45:14.147016	                      0.000000302                      0.000003362                      0.000001582                            12.58                             0.85                             6.10                             0.01
11/19/2013 10:45:15.146891	                      0.000000304                      0.000003362                      0.000001538                            12.58                             0.61                             6.10                             0.01
11/19/2013 10:45:16.146881	                      0.000000304                      0.000003362                      0.000001560                            16.02                             0.42                             6.10                             0.01
11/19/2013 10:45:17.147759	                      0.000000302                      0.000003362                      0.000001560                            16.02                             0.42                             6.10                             0.01
11/19/2013 10:45:18.147575	                      0.000000302                      0.000003384                      0.000001560                             3.43                             0.42                             6.10                             0.01
11/19/2013 10:45:19.147328	                      0.000000302                      0.000003362                      0.000001560                             3.43                             0.42                             6.10                             0.01
11/19/2013 10:45:20.147232	                      0.000000300                      0.000003384                      0.000001582                            11.44                             0.42                             6.10                             0.01
11/19/2013 10:45:21.148144	                      0.000000302                      0.000003384                      0.000001560                            14.87                             0.48                             6.10                             0.01
11/19/2013 10:45:22.149018	                      0.000000304                      0.000003362                      0.000001560                            18.31                             0.48                             6.10                             0.01
11/19/2013 10:45:23.150194	                      0.000000306                      0.000003384                      0.000001560                            18.31                             0.48                             6.10                             0.01
11/19/2013 10:45:24.150804	                      0.000000302                      0.000003362                      0.000001582                            21.74                             0.48                             6.10                             0.01
11/19/2013 10:45:25.150602	                      0.000000300                      0.000003362                      0.000001582                            21.74                             0.48                             6.10                             0.01
11/19/2013 10:45:26.150449	                      0.000000300                      0.000003384                      0.000001538                            21.74                             0.48                             6.10                             0.01
11/19/2013 10:45:27.151409	                      0.000000304                      0.000003384                      0.000001560                            21.74                             0.48                             6.10                             0.01
11/19/2013 10:45:28.151267	                      0.000000304                      0.000003362                      0.000001560                            22.88                             0.48                             6.10                             0.01
11/19/2013 10:45:29.151108	                      0.000000302                      0.000003362                      0.000001582                            22.88                             0.48                             6.10                             0.01
11/19/2013 10:45:30.151084	                      0.000000300                      0.000003362                      0.000001560                            24.03                             0.24                             6.10                             0.01
11/19/2013 10:45:31.150818	                      0.000000300                      0.000003362                      0.000001538                            11.44                             0.24                             6.10                             0.01
11/19/2013 10:45:32.151726	                      0.000000302                      0.000003362                      0.000001538                           510.41                             2.92                             7.32                             0.01
11/19/2013 10:45:33.151733	                      0.000000302                      0.000003362                      0.000001538                           511.55                             0.12                             7.32                             0.01
11/19/2013 10:45:34.151441	                      0.000000302                      0.000003362                      0.000001560                          1511.78                             3.84                             7.93                             0.01
11/19/2013 10:45:35.151315	                      0.000000302                      0.000003362                      0.000001582                          2011.90                             2.86                             9.15                             0.01
11/19/2013 10:45:36.151190	                      0.000000302                      0.000003362                      0.000001560                          3512.24                            12.14                             9.76                             0.01
11/19/2013 10:45:37.151117	                      0.000000302                      0.000003362                      0.000001538                          5517.28                            11.16                             9.76                             0.01
11/19/2013 10:45:38.150938	                      0.000000302                      0.000003362                      0.000001560                          7514.30                            17.15                            15.25                             0.01
11/19/2013 10:45:39.150851	                      0.000000306                      0.000003384                      0.000001582                          9015.79                            12.32                            15.25                             0.01
11/19/2013 10:45:40.150756	                      0.000000302                      0.000003384                      0.000001582                         11016.25                            15.25                            15.25                             0.01
11/19/2013 10:45:41.150571	                      0.000000302                      0.000003384                      0.000001560                         13016.70                            17.94                            15.25                             0.01
11/19/2013 10:45:42.151464	                      0.000000304                      0.000003362                      0.000001560                         14518.19                            19.22                            16.47                             0.01
11/19/2013 10:45:43.151354	                      0.000000302                      0.000003362                      0.000001582                         16522.08                            22.33                            16.47                             0.01
11/19/2013 10:45:44.151303	                      0.000000302                      0.000003384                      0.000001582                         18519.11                            23.49                            17.09                             0.01
11/19/2013 10:45:45.151188	                      0.000000302                      0.000003362                      0.000001582                         20585.94                            28.56                            17.09                             0.01
11/19/2013 10:45:46.151036	                      0.000000302                      0.000003362                      0.000001582                         22523.46                            30.76                            17.70                             0.01
11/19/2013 10:45:47.152035	                      0.000000302                      0.000003362                      0.000001582                         24521.62                            28.44                            17.70                             0.01
11/19/2013 10:45:48.151742	                      0.000000302                      0.000003384                      0.000001582                         26520.94                            31.37                            17.09                             0.01
11/19/2013 10:45:49.151657	                      0.000000304                      0.000003362                      0.000001560                         28524.83                            31.73                            17.70                             0.01
11/19/2013 10:45:50.151484	                      0.000000306                      0.000003362                      0.000001582                         30025.17                            35.09                            17.70                             0.01
11/19/2013 10:45:51.151476	                      0.000000304                      0.000003362                      0.000001582                         32027.92                            40.10                            17.70                             0.01
11/19/2013 10:45:52.151329	                      0.000000302                      0.000003384                      0.000001560                         34024.94                            42.54                            17.70                             0.01
11/19/2013 10:45:53.151052	                      0.000000302                      0.000003362                      0.000001538                         36027.69                            38.87                            17.70                             0.01
11/19/2013 10:45:54.150967	                      0.000000304                      0.000003362                      0.000001560                         37528.03                            43.15                            17.70                             0.01
11/19/2013 10:45:55.150804	                      0.000000304                      0.000003362                      0.000001560                         39026.09                            43.09                            17.09                             0.01
11/19/2013 10:45:56.150672	                      0.000000304                      0.000003384                      0.000001560                         40528.72                            43.88                            17.09                             0.01
11/19/2013 10:45:57.151583	                      0.000000306                      0.000003384                      0.000001538                         42027.92                            45.96                            15.25                             0.01
11/19/2013 10:45:58.151490	                      0.000000302                      0.000003362                      0.000001560                         43094.52                            46.50                            15.25                             0.01
11/19/2013 10:45:59.151326	                      0.000000300                      0.000003362                      0.000001538                         44528.49                            48.64                            31.12                             0.01
11/19/2013 10:46:00.151211	                      0.000000302                      0.000003362                      0.000001560                         45529.86                            49.74                            50.65                             0.01
11/19/2013 10:46:01.151080	                      0.000000304                      0.000003384                      0.000001538                         47031.35                            51.33                            68.36                             0.01
11/19/2013 10:46:02.151382	                      0.000000304                      0.000003384                      0.000001538                         48028.15                            54.07                            78.73                             0.01
11/19/2013 10:46:03.151823	                      0.000000304                      0.000003384                      0.000001582                         49029.52                            54.44                            76.90                             0.01
... 2782 more lines ...
  553   Wednesday, November 20, 2013, 13:52 Bevan MossConditioning StationStandard OperationTM2 HV testing of TM2

 HV testing without the cover continued today. With the EINZEL lens at 30kV the target module was able to achieve 58.7kV. At this voltage any spark was reeking havoc on the electronics of the TCS. Vacuum gauges signals were occasionally lost, the thermocouple reading would occasionally be lost, turbo pump would turn off. All of these events caused the interlocks to trip resulting in the power supplies to be turned off. As a result I bypassed majority of the interlocks to prevent this from happening. Ultimately as spark took out the CANBUS controller first for the EINZEL lens and then for the BIAS. David Morris has been contacted to have them replaced. The damage of the CANBUS controller for these power supplies is becoming a common problem and should be investigated for if there is a better solution. During testing I experimented with raising the BIAS to near its limit followed by the EINZEL lens and vise versa. From this it was determined that the EINZEL must be raised to high voltage before the BIAS otherwise sparking occurs. Even a step from 0 to 500 volts on the ENIZEL lens with the BIAS at 55kV caused sparking. There are a few combinations of testing along this line I would like to continue with but initially my though is that the BIAS and ENIZEL do not have sufficient clearance for the BIAS to operate above 55kV. Attached is a screen shot of the strip tool and the data. I have not heard from David yet but I do not expect the TCS to be operational today. 

Attachment 1: 20112013_HV_conditioning_TM2.JPG
20112013_HV_conditioning_TM2.JPG
Attachment 2: 20112013_TM2_No_source_tray_HV_Test_no_cover.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
11/20/2013 10:34:48.414676	                      0.000000253                      0.000003120                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:49.413724	                      0.000000253                      0.000003098                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:50.414780	                      0.000000256                      0.000003120                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:51.414583	                      0.000000258                      0.000003120                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:52.414423	                      0.000000260                      0.000003120                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:53.415237	                      0.000000258                      0.000003120                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:54.416059	                      0.000000258                      0.000003098                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:55.506062	                      0.000000258                      0.000003098                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:56.506814	                      0.000000258                      0.000003120                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:57.506697	                      0.000000256                      0.000003098                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:58.506780	                      0.000000258                      0.000003120                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:59.506511	                      0.000000260                      0.000003120                      0.000001252                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:00.507321	                      0.000000258                      0.000003120                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:01.507271	                      0.000000258                      0.000003120                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:02.507196	                      0.000000256                      0.000003098                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:03.507937	                      0.000000256                      0.000003098                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:04.508830	                      0.000000256                      0.000003098                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:05.509815	                      0.000000253                      0.000003120                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:06.510560	                      0.000000258                      0.000003120                      0.000001208                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:07.511442	                      0.000000260                      0.000003120                      0.000001208                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:08.511382	                      0.000000258                      0.000003098                      0.000001208                            27.46                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:09.511380	                      0.000000260                      0.000003120                      0.000001252                            26.32                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:10.511063	                      0.000000258                      0.000003120                      0.000001252                            26.32                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:11.510938	                      0.000000256                      0.000003098                      0.000001252                            27.46                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:12.510832	                      0.000000256                      0.000003120                      0.000001208                            27.46                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:13.510688	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                           BadVal                           BadVal
11/20/2013 10:35:14.510527	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                           BadVal                           BadVal
11/20/2013 10:35:15.510410	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                           BadVal                           BadVal
11/20/2013 10:35:16.510321	                      0.000000256                      0.000003098                      0.000001230                            27.46                             0.42                           BadVal                           BadVal
11/20/2013 10:35:17.510214	                      0.000000256                      0.000003098                      0.000001230                            26.32                             0.42                           BadVal                           BadVal
11/20/2013 10:35:18.510025	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                           BadVal
11/20/2013 10:35:19.509934	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                           BadVal
11/20/2013 10:35:20.509860	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                           BadVal
11/20/2013 10:35:21.511728	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                           BadVal
11/20/2013 10:35:22.511632	                      0.000000260                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                           BadVal
11/20/2013 10:35:23.511584	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:24.591659	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:25.729112	                      0.000000253                      0.000003098                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:26.729088	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:27.729906	                      0.000000253                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:28.729930	                      0.000000260                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:29.729660	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:30.729489	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:31.729372	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:32.730305	                      0.000000253                      0.000003098                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:33.853965	                      0.000000256                      0.000003120                      0.000001252                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:34.854006	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:35.949159	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:36.949749	                      0.000000256                      0.000003098                      0.000001252                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:37.949644	                      0.000000256                      0.000003120                      0.000001252                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:38.949535	                      0.000000256                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:39.950466	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:41.28198	                      0.000000256                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:42.34724	                      0.000000256                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:43.34971	                      0.000000256                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:44.34865	                      0.000000260                      0.000003098                      0.000001252                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:45.34739	                      0.000000258                      0.000003120                      0.000001252                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:46.34576	                      0.000000258                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:47.34484	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:48.35380	                      0.000000258                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:49.35302	                      0.000000256                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:50.36136	                      0.000000253                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:51.35938	                      0.000000253                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:52.35873	                      0.000000260                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:53.35802	                      0.000000260                      0.000003098                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:54.35700	                      0.000000260                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:55.35442	                      0.000000260                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:56.35354	                      0.000000256                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:57.35238	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:58.36111	                      0.000000253                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:59.35984	                      0.000000260                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:00.35832	                      0.000000260                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:01.35689	                      0.000000260                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:02.144399	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:03.144478	                      0.000000258                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:04.144502	                      0.000000256                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:05.145332	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:06.145089	                      0.000000253                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:07.145209	                      0.000000260                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:08.145838	                      0.000000260                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:09.146802	                      0.000000260                      0.000003098                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:10.146584	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:11.146460	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:12.146294	                      0.000000256                      0.000003098                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:13.146305	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:14.146042	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:15.145915	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:16.145794	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:17.145705	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:18.145906	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:19.145434	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:20.145323	                      0.000000253                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:21.145202	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:22.145076	                      0.000000260                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:23.146118	                      0.000000260                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:24.145825	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:25.155723	                      0.000000258                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:26.155570	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:27.155437	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:28.155279	                      0.000000256                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:29.155155	                      0.000000256                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:30.155132	                      0.000000256                      0.000003098                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:31.155083	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:32.154768	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:33.154675	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:34.154594	                      0.000000253                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:35.155716	                      0.000000256                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:36.156306	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:37.156322	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:38.156054	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:39.155899	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:40.313843	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:41.313756	                      0.000000253                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:42.313502	                      0.000000253                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:43.313407	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:44.313288	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:45.313123	                      0.000000258                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:46.313028	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:47.312863	                      0.000000256                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:48.313869	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:49.314706	                      0.000000256                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:50.315547	                      0.000000253                      0.000003120                      0.000001186                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:51.315404	                      0.000000260                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:52.315285	                      0.000000256                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:53.316161	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:54.316185	                      0.000000260                      0.000003098                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:55.317074	                      0.000000256                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:56.316803	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:57.316655	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:58.316082	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:59.316373	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:37:00.316469	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:37:01.316114	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             0.61                             0.01
11/20/2013 10:37:02.316025	                      0.000000260                      0.000003098                      0.000001230                            26.32                             0.42                             0.61                             0.01
11/20/2013 10:37:03.316970	                      0.000000260                      0.000003120                      0.000001230                             8.01                             0.42                             0.61                             0.01
11/20/2013 10:37:04.316771	                      0.000000256                      0.000003120                      0.000001230                             8.01                             0.42                             0.61                             0.01
11/20/2013 10:37:05.316651	                      0.000000253                      0.000003098                      0.000001230                             9.15                             0.79                             4.27                             0.01
11/20/2013 10:37:06.316545	                      0.000000256                      0.000003098                      0.000001230                             9.15                             0.79                             4.27                             0.01
11/20/2013 10:37:07.316358	                      0.000000256                      0.000003120                      0.000001230                            12.58                             0.79                             6.10                             0.01
11/20/2013 10:37:08.317387	                      0.000000256                      0.000003120                      0.000001208                            12.58                             0.79                             5.49                             0.01
11/20/2013 10:37:09.318100	                      0.000000256                      0.000003076                      0.000001208                            10.29                             0.91                             5.49                             0.01
11/20/2013 10:37:10.317973	                      0.000000256                      0.000003098                      0.000001230                            12.58                             0.73                             5.49                             0.01
11/20/2013 10:37:11.317854	                      0.000000256                      0.000003120                      0.000001208                         12098.87                             6.77                            30.51                             0.01
11/20/2013 10:37:12.317785	                      0.000000253                      0.000003120                      0.000001208                          9037.53                             5.37                             8.54                             0.01
11/20/2013 10:37:13.318646	                      0.000000256                      0.000003120                      0.000001208                          6778.43                             4.08                             8.54                             0.01
11/20/2013 10:37:14.318517	                      0.000000258                      0.000003120                      0.000001208                          5105.28                             3.41                             3.05                             0.01
11/20/2013 10:37:15.318456	                      0.000000258                      0.000003120                      0.000001208                          3855.57                             2.86                             3.05                             0.01
11/20/2013 10:37:16.319259	                      0.000000256                      0.000003120                      0.000001230                          2921.72                             1.95                             0.61                             0.01
11/20/2013 10:37:17.319100	                      0.000000256                      0.000003120                      0.000001208                          2237.35                             1.58                             0.61                             0.01
11/20/2013 10:37:18.320004	                      0.000000253                      0.000003120                      0.000001230                          1826.50                             1.15                             1.83                             0.01
11/20/2013 10:37:19.320985	                      0.000000256                      0.000003120                      0.000001208                          1478.59                             1.15                             1.83                             0.01
11/20/2013 10:37:20.320764	                      0.000000258                      0.000003120                      0.000001208                          1197.07                             1.03                             3.66                             0.01
11/20/2013 10:37:21.320666	                      0.000000253                      0.000003120                      0.000001230                           969.32                             1.03                             3.66                             0.01
11/20/2013 10:37:22.321547	                      0.000000258                      0.000003120                      0.000001230                           785.07                             1.03                             4.27                             0.01
11/20/2013 10:37:23.322366	                      0.000000258                      0.000003120                      0.000001230                           635.15                             1.03                             4.27                             0.01
11/20/2013 10:37:24.322396	                      0.000000258                      0.000003120                      0.000001230                           513.84                             0.91                             4.27                             0.01
11/20/2013 10:37:25.322137	                      0.000000256                      0.000003120                      0.000001230                           415.42                             0.91                             4.27                             0.01
11/20/2013 10:37:26.321987	                      0.000000256                      0.000003142                      0.000001230                           335.31                             0.91                             4.88                             0.01
11/20/2013 10:37:27.321928	                      0.000000253                      0.000003120                      0.000001208                           270.08                             0.91                             4.88                             0.01
11/20/2013 10:37:28.322956	                      0.000000256                      0.000003098                      0.000001230                           216.29                             0.91                             4.88                             0.01
11/20/2013 10:37:29.323592	                      0.000000256                      0.000003098                      0.000001230                           179.67                             0.91                             4.88                             0.01
11/20/2013 10:37:30.323486	                      0.000000256                      0.000003142                      0.000001230                           141.90                             0.91                             4.88                             0.01
11/20/2013 10:37:31.323450	                      0.000000258                      0.000003120                      0.000001230                           108.72                             0.91                             4.88                             0.01
11/20/2013 10:37:32.323271	                      0.000000258                      0.000003120                      0.000001208                            89.26                             0.91                             4.88                             0.01
11/20/2013 10:37:33.324362	                      0.000000258                      0.000003098                      0.000001208                            70.95                             0.91                             4.88                             0.01
11/20/2013 10:37:34.324005	                      0.000000256                      0.000003120                      0.000001208                            53.78                             0.91                             5.49                             0.01
11/20/2013 10:37:35.323838	                      0.000000256                      0.000003120                      0.000001208                            53.78                             0.91                             1.83                             0.01
11/20/2013 10:37:36.324765	                      0.000000258                      0.000003120                      0.000001230                            33.18                             0.91                             1.83                             0.01
11/20/2013 10:37:37.324726	                      0.000000258                      0.000003120                      0.000001230                            17.16                             0.91                             1.22                             0.01
11/20/2013 10:37:38.325505	                      0.000000258                      0.000003120                      0.000001186                            17.16                             0.91                             1.22                             0.01
11/20/2013 10:37:39.325336	                      0.000000258                      0.000003098                      0.000001208                             4.57                             0.36                             1.22                             0.01
11/20/2013 10:37:40.325348	                      0.000000260                      0.000003120                      0.000001230                             4.57                             0.36                             1.22                             0.01
11/20/2013 10:37:41.325141	                      0.000000258                      0.000003120                      0.000001230                            12.58                             0.79                             1.22                             0.01
11/20/2013 10:37:42.325021	                      0.000000256                      0.000003120                      0.000001230                            12.58                             0.79                             1.22                             0.01
11/20/2013 10:37:43.325865	                      0.000000253                      0.000003120                      0.000001230                             9.15                             0.91                             0.61                             0.01
11/20/2013 10:37:44.325763	                      0.000000258                      0.000003120                      0.000001230                             9.15                             0.91                             0.61                             0.01
11/20/2013 10:37:45.325605	                      0.000000258                      0.000003098                      0.000001230                            10.29                             0.91                             0.61                             0.01
11/20/2013 10:37:46.325508	                      0.000000253                      0.000003120                      0.000001230                            10.29                             0.91                             0.61                             0.01
11/20/2013 10:37:47.325388	                      0.000000256                      0.000003098                      0.000001230                             5.72                             0.91                           998.55                             0.04
11/20/2013 10:37:48.326442	                      0.000000258                      0.000003120                      0.000001230                             5.72                             0.91                          3000.53                             0.09
11/20/2013 10:37:49.326181	                      0.000000256                      0.000003098                      0.000001252                             8.01                             0.91                          4500.80                             0.23
11/20/2013 10:37:50.325945	                      0.000000256                      0.000003120                      0.000001230                             8.01                             0.91                          5001.90                             0.23
11/20/2013 10:37:51.326819	                      0.000000256                      0.000003120                      0.000001230                             5.72                             0.91                          5568.93                             0.23
11/20/2013 10:37:52.326754	                      0.000000256                      0.000003120                      0.000001230                             5.72                             0.91                          7003.28                             0.23
11/20/2013 10:37:53.327593	                      0.000000256                      0.000003142                      0.000001230                             5.72                             0.91                          8003.66                             0.23
11/20/2013 10:37:54.327448	                      0.000000256                      0.000003120                      0.000001208                            13.73                             0.91                          9502.70                             0.53
11/20/2013 10:37:55.328351	                      0.000000260                      0.000003120                      0.000001230                            13.73                             0.91                         10506.14                             0.35
11/20/2013 10:37:56.328292	                      0.000000258                      0.000003120                      0.000001208                            17.16                             0.91                         11781.79                             0.38
11/20/2013 10:37:57.328116	                      0.000000256                      0.000003120                      0.000001208                            17.16                             0.91                         13006.17                             0.44
11/20/2013 10:37:58.328287	                      0.000000256                      0.000003120                      0.000001208                             9.15                             0.91                         14505.83                             0.44
11/20/2013 10:37:59.328830	                      0.000000256                      0.000003120                      0.000001208                             8.01                             0.91                         16503.54                             0.58
11/20/2013 10:38:00.328696	                      0.000000256                      0.000003120                      0.000001230                             8.01                             0.91                         18006.86                             0.58
11/20/2013 10:38:01.328586	                      0.000000256                      0.000003098                      0.000001230                            12.58                             0.91                         19506.52                             0.69
11/20/2013 10:38:02.329506	                      0.000000258                      0.000003098                      0.000001208                            12.58                             0.91                         21007.40                             0.79
11/20/2013 10:38:03.330336	                      0.000000258                      0.000003120                      0.000001208                            12.58                             0.91                         22507.66                             0.79
11/20/2013 10:38:04.330331	                      0.000000258                      0.000003098                      0.000001208                             4.57                             0.91                         23011.21                             0.80
11/20/2013 10:38:05.330125	                      0.000000256                      0.000003120                      0.000001208                             4.57                             0.91                         24009.15                             0.81
11/20/2013 10:38:06.329942	                      0.000000256                      0.000003120                      0.000001208                            12.58                             0.79                         25008.31                             0.81
11/20/2013 10:38:07.329857	                      0.000000258                      0.000003098                      0.000001208                            12.58                             0.79                         25010.14                             0.81
11/20/2013 10:38:08.330714	                      0.000000258                      0.000003098                      0.000001208                             5.72                             0.91                         25010.14                             0.81
11/20/2013 10:38:09.330602	                      0.000000260                      0.000003098                      0.000001230                             5.72                             0.91                         25011.97                             0.81
11/20/2013 10:38:10.330506	                      0.000000253                      0.000003098                      0.000001230                             5.72                             0.73                         25011.97                             0.81
11/20/2013 10:38:11.331338	                      0.000000258                      0.000003098                      0.000001230                             5.72                             0.73                         25011.97                             0.81
11/20/2013 10:38:12.331188	                      0.000000258                      0.000003120                      0.000001252                             6.86                             0.73                         25011.97                             0.81
11/20/2013 10:38:13.332192	                      0.000000258                      0.000003120                      0.000001252                             6.86                             0.73                         25011.97                             0.81
11/20/2013 10:38:14.331985	                      0.000000256                      0.000003120                      0.000001252                            10.29                             0.85                         25011.97                             0.81
11/20/2013 10:38:15.331812	                      0.000000256                      0.000003120                      0.000001208                            10.29                             0.85                         25012.58                             0.81
11/20/2013 10:38:16.331676	                      0.000000256                      0.000003120                      0.000001208                            13.73                             0.85                         25012.58                             0.81
11/20/2013 10:38:17.331599	                      0.000000258                      0.000003120                      0.000001208                            13.73                             0.85                         25012.58                             0.81
11/20/2013 10:38:18.331562	                      0.000000260                      0.000003098                      0.000001208                            10.29                             0.85                         25012.58                             0.81
11/20/2013 10:38:19.331349	                      0.000000256                      0.000003120                      0.000001230                            10.29                             0.85                         25012.58                             0.81
11/20/2013 10:38:20.331173	                      0.000000256                      0.000003120                      0.000001230                             8.01                             0.85                         25012.58                             0.81
11/20/2013 10:38:21.331084	                      0.000000258                      0.000003120                      0.000001230                            10.29                             0.85                         25012.58                             0.81
11/20/2013 10:38:22.331021	                      0.000000256                      0.000003120                      0.000001230                            10.29                             0.85                         25012.58                             0.81
11/20/2013 10:38:23.330936	                      0.000000256                      0.000003120                      0.000001230                             9.15                             0.85                         25012.58                             0.81
11/20/2013 10:38:24.330710	                      0.000000260                      0.000003120                      0.000001230                             9.15                             0.85                         25012.58                             0.81
11/20/2013 10:38:25.330593	                      0.000000256                      0.000003120                      0.000001208                             8.01                             0.73                         25012.58                             0.81
11/20/2013 10:38:26.330462	                      0.000000258                      0.000003120                      0.000001208                             8.01                             0.73                         25012.58                             0.81
11/20/2013 10:38:27.330338	                      0.000000256                      0.000003120                      0.000001208                            10.29                             0.91                         25012.58                             0.81
11/20/2013 10:38:28.331226	                      0.000000253                      0.000003120                      0.000001230                            10.29                             0.91                         25012.58                             0.81
11/20/2013 10:38:29.331092	                      0.000000258                      0.000003120                      0.000001230                            13.73                             0.91                         25012.58                             0.81
11/20/2013 10:38:30.331004	                      0.000000258                      0.000003098                      0.000001230                            13.73                             0.91                         25012.58                             0.81
11/20/2013 10:38:31.330795	                      0.000000258                      0.000003098                      0.000001208                             6.86                             0.91                         25012.58                             0.81
11/20/2013 10:38:32.330772	                      0.000000260                      0.000003120                      0.000001208                             6.86                             0.91                         25012.58                             0.81
11/20/2013 10:38:33.331565	                      0.000000260                      0.000003098                      0.000001208                             9.15                             0.79                         25012.58                             0.81
11/20/2013 10:38:34.331463	                      0.000000258                      0.000003098                      0.000001230                             9.15                             0.79                         25012.58                             0.81
11/20/2013 10:38:35.331347	                      0.000000256                      0.000003120                      0.000001208                            14.87                             0.61                         25012.58                             0.81
11/20/2013 10:38:36.331211	                      0.000000258                      0.000003120                      0.000001208                            14.87                             0.61                         25012.58                             0.81
11/20/2013 10:38:37.331045	                      0.000000258                      0.000003098                      0.000001230                            13.73                             0.85                         25012.58                             0.81
11/20/2013 10:38:38.330950	                      0.000000256                      0.000003098                      0.000001230                            13.73                             0.85                         25012.58                             0.81
11/20/2013 10:38:39.330833	                      0.000000258                      0.000003120                      0.000001186                             6.86                             0.73                         25012.58                             0.81
11/20/2013 10:38:40.330708	                      0.000000256                      0.000003120                      0.000001208                             6.86                             0.73                         25012.58                             0.81
11/20/2013 10:38:41.330581	                      0.000000258                      0.000003098                      0.000001230                             9.15                             0.85                         25012.58                             0.81
11/20/2013 10:38:42.330469	                      0.000000253                      0.000003098                      0.000001186                             6.86                             0.73                         25012.58                             0.81
11/20/2013 10:38:43.331408	                      0.000000256                      0.000003120                      0.000001230                             6.86                             0.85                         25012.58                             0.81
11/20/2013 10:38:44.331413	                      0.000000256                      0.000003120                      0.000001230                          1010.52                             2.99                         25012.58                             0.81
11/20/2013 10:38:45.332046	                      0.000000256                      0.000003120                      0.000001208                          1791.02                             5.61                         25012.58                             0.81
11/20/2013 10:38:46.331944	                      0.000000258                      0.000003098                      0.000001230                          2512.01                             3.90                         25012.58                             0.81
11/20/2013 10:38:47.331830	                      0.000000258                      0.000003120                      0.000001208                          3010.98                             9.94                         25012.58                             0.81
11/20/2013 10:38:48.332698	                      0.000000256                      0.000003120                      0.000001230                          4012.35                             4.51                         25012.58                             0.81
11/20/2013 10:38:49.332575	                      0.000000258                      0.000003120                      0.000001230                          5012.58                             7.75                         25012.58                             0.81
11/20/2013 10:38:50.332461	                      0.000000253                      0.000003098                      0.000001230                          6013.96                             6.65                         25012.58                             0.81
11/20/2013 10:38:51.332339	                      0.000000256                      0.000003098                      0.000001230                          7017.62                            11.41                         25012.58                             0.81
11/20/2013 10:38:52.332236	                      0.000000256                      0.000003098                      0.000001230                          8514.53                            10.43                         25012.58                             0.81
11/20/2013 10:38:53.333086	                      0.000000256                      0.000003098                      0.000001230                          9515.90                            17.09                         25012.58                             0.81
11/20/2013 10:38:54.332965	                      0.000000256                      0.000003098                      0.000001230                         11016.25                            14.95                         25012.58                             0.81
11/20/2013 10:38:55.332817	                      0.000000256                      0.000003120                      0.000001230                         12019.91                            16.35                         25012.58                             0.81
11/20/2013 10:38:56.332686	                      0.000000253                      0.000003098                      0.000001186                         13292.51                            16.41                         25012.58                             0.81
11/20/2013 10:38:57.332571	                      0.000000256                      0.000003120                      0.000001186                         14518.19                            15.93                         25012.58                             0.81
11/20/2013 10:38:58.333428	                      0.000000256                      0.000003120                      0.000001230                         15519.56                            15.68                         25012.58                             0.81
11/20/2013 10:38:59.333281	                      0.000000256                      0.000003120                      0.000001230                         16520.94                            16.11                         25012.58                             0.81
11/20/2013 10:39:00.333153	                      0.000000256                      0.000003098                      0.000001208                         18018.99                            24.23                         25012.58                             0.81
11/20/2013 10:39:01.333093	                      0.000000253                      0.000003142                      0.000001208                         19022.65                            22.70                         25012.58                             0.81
11/20/2013 10:39:02.333017	                      0.000000260                      0.000003120                      0.000001230                         20521.85                            21.30                         25012.58                             0.81
11/20/2013 10:39:03.333874	                      0.000000256                      0.000003098                      0.000001230                         22022.20                            23.25                         25012.58                             0.81
11/20/2013 10:39:04.333737	                      0.000000258                      0.000003098                      0.000001208                         23469.90                            26.06                         25012.58                             0.81
11/20/2013 10:39:05.333680	                      0.000000256                      0.000003120                      0.000001230                         24522.77                            24.71                         25012.58                             0.81
11/20/2013 10:39:06.333393	                      0.000000256                      0.000003120                      0.000001230                         26023.11                            28.99                         25012.58                             0.81
11/20/2013 10:39:07.333417	                      0.000000258                      0.000003120                      0.000001208                         27523.46                            29.35                         25012.58                             0.81
11/20/2013 10:39:08.334148	                      0.000000258                      0.000003120                      0.000001230                         29026.09                            31.31                         25012.58                             0.81
11/20/2013 10:39:09.334056	                      0.000000256                      0.000003120                      0.000001230                         30523.00                            32.53                         25012.58                             0.81
11/20/2013 10:39:10.333927	                      0.000000253                      0.000003120                      0.000001230                         31525.52                            31.67                         25012.58                             0.81
11/20/2013 10:39:11.333973	                      0.000000256                      0.000003120                      0.000001230                         32528.03                            30.15                         25012.58                             0.81
11/20/2013 10:39:12.334739	                      0.000000256                      0.000003120                      0.000001230                         33801.78                            36.19                         25012.58                             0.81
11/20/2013 10:39:13.335695	                      0.000000253                      0.000003120                      0.000001230                         35026.32                            35.33                         25012.58                             0.81
11/20/2013 10:39:14.335425	                      0.000000253                      0.000003120                      0.000001230                         36474.02                            39.06                         25012.58                             0.81
11/20/2013 10:39:15.336686	                      0.000000253                      0.000003098                      0.000001230                         37526.89                            38.20                         25012.58                             0.81
11/20/2013 10:39:16.337275	                      0.000000258                      0.000003098                      0.000001230                         38527.12                            38.20                         25012.58                             0.81
11/20/2013 10:39:17.338221	                      0.000000253                      0.000003098                      0.000001208                         39974.82                            39.61                         25012.58                             0.81
11/20/2013 10:39:18.338918	                      0.000000253                      0.000003098                      0.000001186                         41027.69                            41.44                         25012.58                             0.81
11/20/2013 10:39:19.338838	                      0.000000256                      0.000003098                      0.000001230                         42029.06                            41.74                         25012.58                             0.81
11/20/2013 10:39:20.338621	                      0.000000256                      0.000003098                      0.000001208                         43028.15                            49.80                         25012.58                             0.81
11/20/2013 10:39:21.338512	                      0.000000256                      0.000003098                      0.000001208                         44526.20                            53.40                         25012.58                             0.81
11/20/2013 10:39:22.338428	                      0.000000258                      0.000003098                      0.000001230                         45528.72                            48.34                         25012.58                             0.81
11/20/2013 10:39:23.339288	                      0.000000258                      0.000003098                      0.000001186                         46528.95                            48.46                         25012.58                             0.81
11/20/2013 10:39:24.339252	                      0.000000253                      0.000003098                      0.000001230                         47529.18                            52.36                         25012.58                             0.81
11/20/2013 10:39:25.339125	                      0.000000256                      0.000003098                      0.000001230                         48975.73                            52.67                         25012.58                             0.81
11/20/2013 10:39:26.338885	                      0.000000256                      0.000003120                      0.000001208                         50026.32                            52.85                         25012.58                             0.81
11/20/2013 10:39:27.338831	                      0.000000256                      0.000003098                      0.000001208                         51027.69                            55.35                         25012.58                             0.81
11/20/2013 10:39:28.339727	                      0.000000258                      0.000003120                      0.000001230                         52025.63                            56.09                         25012.58                             0.81
11/20/2013 10:39:29.339894	                      0.000000256                      0.000003120                      0.000001230                         53027.00                            56.45                         25012.58                             0.81
11/20/2013 10:39:30.340396	                      0.000000256                      0.000003120                      0.000001230                         54030.67                            62.74                         25012.58                             0.81
11/20/2013 10:39:31.340369	                      0.000000260                      0.000003120                      0.000001230                         54594.87                            66.28                         25012.58                             0.81
11/20/2013 10:39:32.340350	                      0.000000253                      0.000003120                      0.000001230                         55528.72                            64.69                         25012.58                             0.81
11/20/2013 10:39:33.341106	                      0.000000260                      0.000003120                      0.000001230                         56029.98                            69.58                         25012.58                             0.81
11/20/2013 10:39:34.340924	                      0.000000260                      0.000003098                      0.000001252                         56031.12                            69.09                         25012.58                             0.81
11/20/2013 10:39:35.340837	                      0.000000319                      0.000003758                      0.000001604                         56032.27                            68.90                         25012.58                             0.81
11/20/2013 10:39:36.340732	                      0.000000306                      0.000003714                      0.000001626                         56032.27                            70.61                         25012.58                             0.81
11/20/2013 10:39:37.341651	                      0.000000300                      0.000003582                      0.000001604                         56032.27                            69.88                         25012.58                             0.81
11/20/2013 10:39:38.342419	                      0.000000291                      0.000003538                      0.000001560                         56032.27                            67.68                         25012.58                             0.81
11/20/2013 10:39:39.342271	                      0.000000291                      0.000003494                      0.000001560                         56032.27                            68.54                         25012.58                             0.81
11/20/2013 10:39:40.342168	                      0.000000289                      0.000003494                      0.000001560                         56032.27                            68.17                         25012.58                             0.81
11/20/2013 10:39:41.341996	                      0.000000289                      0.000003472                      0.000001494                         56032.27                            66.77                         25012.58                             0.81
11/20/2013 10:39:42.341916	                      0.000000284                      0.000003450                      0.000001494                         56032.27                            67.99                         25012.58                             0.81
11/20/2013 10:39:43.342793	                      0.000000284                      0.000003450                      0.000001472                         56032.27                            66.10                         25012.58                             0.81
11/20/2013 10:39:44.342661	                      0.000000282                      0.000003384                      0.000001450                         56032.27                            67.01                         25012.58                             0.81
11/20/2013 10:39:45.342577	                      0.000000282                      0.000003384                      0.000001450                         56032.27                            67.32                         25012.58                             0.81
11/20/2013 10:39:46.343125	                      0.000000282                      0.000003362                      0.000001450                         56032.27                            67.13                         25012.58                             0.81
11/20/2013 10:39:47.343318	                      0.000000282                      0.000003384                      0.000001450                         56032.27                            65.24                         25012.58                             0.81
... 10427 more lines ...
  565   Tuesday, December 03, 2013, 14:14 Bevan MossConditioning StationStandard OperationTM2 HV conditioning

 It was attempted to HV condition TM2 to 55kV and leave it operating there for an hour to demonstrate stability. Unfortunately at 52.65kV a spark destroyed the canbus controller. This controller had shown issues in the past but seemed to magically fixed itself. I will contact Hubert for another card. Attached  is is a screen shot of the stip tools. 

Attachment 1: TM2_conditioning_03122013.JPG
TM2_conditioning_03122013.JPG
  575   Friday, December 06, 2013, 15:09 Bevan MossConditioning StationStandard OperationTM2 TM2 no source tray 55kV 1 hour

Today 55kV was applied to TM2 and held for over 1 hour with the EINZEL at 27.5kV. There were 2 sparks and the current was unstable at this voltage but this test should be considered a success. Once again while bringing the voltage up the canbus continued to be a problem. After successfully passing the test I continued to raise the BIAS and EINZEL. A spark at 57kV tripped a controller for the vacuum and the canbus. As stated before I believe the module will reach 60kV and that there is an interaction between the EINZEL and the BIAS. I am not certain if that interaction is internal or external to the module. Attached is a screen shot and the dumped data.

Attachment 1: 06122013_TM2_No_source_Tray_55kV_1_hour.JPG
06122013_TM2_No_source_Tray_55kV_1_hour.JPG
Attachment 2: 06122013_TM2_No_Source_Tray_55kV_1_Hour.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:DIC1:RDCOND [Mohm]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
12/06/2013 10:34:30.138858	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:31.138402	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:32.138289	                      0.000000093                      0.000001010                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:33.138127	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:34.138033	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:35.137874	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:36.137749	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:37.137657	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:38.137550	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:39.138452	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:40.138322	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:41.138150	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:42.139015	                      0.000000094                      0.000000996                      0.000000768                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:43.138906	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:44.138797	                      0.000000093                      0.000000996                      0.000000765                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:45.138654	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:46.144533	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:47.144548	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:48.144363	                      0.000000093                      0.000000998                      0.000000768                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:49.144158	                      0.000000093                      0.000000996                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:50.144148	                      0.000000093                      0.000000996                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:51.144894	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:52.144785	                      0.000000093                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:53.144636	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:54.144483	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:55.157531	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:56.158254	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:57.158119	                      0.000000094                      0.000001032                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:58.157969	                      0.000000094                      0.000001010                      0.000000768                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:59.158877	                      0.000000093                      0.000000998                      0.000000768                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:00.159762	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:01.159615	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:03.306946	                      0.000000093                      0.000000996                      0.000000768                             16.9                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:04.307252	                      0.000000094                      0.000000998                      0.000000768                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:05.308070	                      0.000000094                      0.000000998                      0.000000768                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:06.308956	                      0.000000094                      0.000000994                      0.000000770                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:07.308826	                      0.000000094                      0.000000994                      0.000000770                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:08.308694	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:09.308573	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:10.309442	                      0.000000094                      0.000001010                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:11.309317	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:12.309197	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:13.309123	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:14.308964	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:15.309987	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:16.309785	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:17.309567	                      0.000000094                      0.000000996                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:18.422297	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:19.422322	                      0.000000094                      0.000000994                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:20.422292	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:21.422265	                      0.000000094                      0.000001010                      0.000000772                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:22.422985	                      0.000000094                      0.000001010                      0.000000772                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:23.532598	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:24.532696	                      0.000000094                      0.000000996                      0.000000772                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:25.700311	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:26.754388	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:27.754303	                      0.000000094                      0.000000996                      0.000000768                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:28.754164	                      0.000000094                      0.000000996                      0.000000768                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:29.808485	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:30.808903	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:31.892662	                      0.000000093                      0.000000996                      0.000000772                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:32.892649	                      0.000000094                      0.000000994                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:33.892524	                      0.000000094                      0.000000994                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:34.892399	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:36.59457	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:37.59452	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:38.58995	                      0.000000094                      0.000000998                      0.000000768                             16.8                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:39.58868	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:40.58702	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:41.59611	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:42.59451	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:43.59465	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:44.69481	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             8.54                             0.01
12/06/2013 10:35:45.70113	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             8.54                             0.01
12/06/2013 10:35:46.69968	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:47.69843	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:48.69730	                      0.000000093                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:49.69609	                      0.000000093                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:50.69501	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:51.70349	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:52.70327	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:53.71064	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:54.71157	                      0.000000094                      0.000000996                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:55.70854	                      0.000000093                      0.000000998                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:56.70728	                      0.000000093                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:57.70696	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:58.71465	                      0.000000094                      0.000000998                      0.000000772                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:59.71304	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:00.72214	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:01.72058	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:02.72037	                      0.000000094                      0.000000996                      0.000000765                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:03.71845	                      0.000000093                      0.000000996                      0.000000768                             16.8                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:36:04.71718	                      0.000000093                      0.000000996                      0.000000770                             16.8                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:36:05.71547	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:06.72545	                      0.000000094                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:07.72467	                      0.000000093                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:08.73208	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:09.73087	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:10.73946	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:11.74864	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:12.74666	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:13.75645	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:14.75641	                      0.000000093                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:15.75369	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:16.136319	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:17.136267	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:18.230037	                      0.000000094                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:19.229817	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:20.229681	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:21.229580	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:22.229431	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:23.229311	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:24.229201	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:25.229010	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:26.228930	                      0.000000094                      0.000000994                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:27.273591	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:28.273699	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:29.274782	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:30.274160	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:31.274279	                      0.000000094                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:32.274186	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:33.276910	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:34.276923	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:35.277751	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:36.277627	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:37.277496	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:38.277402	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:39.277265	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:40.277272	                      0.000000093                      0.000001010                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:41.278116	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:42.277876	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:43.277804	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:44.277667	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:45.277528	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:46.279324	                      0.000000094                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:47.279479	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:48.280171	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:49.280032	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:50.279918	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:51.280727	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:52.280665	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:53.280477	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:54.280361	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:55.280370	                      0.000000094                      0.000000994                      0.000000770                             16.7                            27.46                             0.06                             9.76                             0.01
12/06/2013 10:36:56.281267	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:57.281021	                      0.000000093                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:58.280911	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:59.280785	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:00.280647	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:01.281537	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:02.281408	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:03.281254	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:04.281106	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:05.281008	                      0.000000093                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:06.281889	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:07.281764	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:08.281734	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:09.281500	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:10.281385	                      0.000000094                      0.000000994                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:11.282277	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.76                             0.01
12/06/2013 10:37:12.282243	                      0.000000093                      0.000000998                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:13.282030	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:14.281905	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:15.281781	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:16.282607	                      0.000000093                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:17.282622	                      0.000000093                      0.000000998                      0.000000768                             16.9                             6.86                             1.03                             9.15                             0.01
12/06/2013 10:37:18.282434	                      0.000000094                      0.000000998                      0.000000770                             16.9                             6.86                             1.03                             1.22                             0.01
12/06/2013 10:37:19.282257	                      0.000000094                      0.000000998                      0.000000770                             16.9                             3.43                             1.03                             1.22                             0.01
12/06/2013 10:37:20.282499	                      0.000000094                      0.000000998                      0.000000770                             16.9                             4.57                             1.03                             1.83                             0.01
12/06/2013 10:37:21.283005	                      0.000000094                      0.000000998                      0.000000770                             16.9                             4.57                             1.03                           493.17                             0.01
12/06/2013 10:37:22.283870	                      0.000000093                      0.000000998                      0.000000770                             16.9                             4.57                             1.03                           993.05                             0.01
12/06/2013 10:37:23.283923	                      0.000000094                      0.000000998                      0.000000770                             16.9                             6.86                             0.91                          1494.16                             0.01
12/06/2013 10:37:24.283648	                      0.000000093                      0.000000996                      0.000000770                             16.9                             3.43                             1.15                          1494.16                             0.01
12/06/2013 10:37:25.283492	                      0.000000094                      0.000000998                      0.000000770                             16.9                            13.73                             1.15                          1994.04                             0.28
12/06/2013 10:37:26.283509	                      0.000000094                      0.000000998                      0.000000770                             16.9                            13.73                             1.15                          1994.04                             0.08
12/06/2013 10:37:27.283262	                      0.000000093                      0.000000998                      0.000000770                             16.8                             5.72                             0.85                          2494.54                             0.10
12/06/2013 10:37:28.283071	                      0.000000093                      0.000000998                      0.000000770                             16.8                             2.28                             0.97                          2995.04                             0.10
12/06/2013 10:37:29.282990	                      0.000000094                      0.000000998                      0.000000770                             16.8                             2.28                             0.97                          3495.53                             0.10
12/06/2013 10:37:30.282877	                      0.000000093                      0.000000998                      0.000000770                             16.8                            10.29                             0.97                          3994.81                             0.15
12/06/2013 10:37:31.283728	                      0.000000094                      0.000000996                      0.000000768                             16.8                             8.01                             0.91                          3994.81                             0.15
12/06/2013 10:37:32.283568	                      0.000000094                      0.000000998                      0.000000768                             16.8                             4.57                             1.15                          3996.03                             0.15
12/06/2013 10:37:33.283508	                      0.000000093                      0.000000998                      0.000000770                             16.8                             6.86                             1.15                          3996.03                             0.15
12/06/2013 10:37:34.283108	                      0.000000094                      0.000000998                      0.000000768                             16.8                             4.57                             1.03                          3996.03                             0.15
12/06/2013 10:37:35.283283	                      0.000000094                      0.000000998                      0.000000768                             16.8                             5.72                             1.03                          3996.03                             0.15
12/06/2013 10:37:36.284116	                      0.000000093                      0.000000994                      0.000000768                             16.8                             5.72                             1.09                          3996.03                             0.15
12/06/2013 10:37:37.283983	                      0.000000094                      0.000000998                      0.000000770                             16.8                             5.72                             1.09                          3996.64                             0.15
12/06/2013 10:37:38.283864	                      0.000000094                      0.000000998                      0.000000770                             16.7                             3.43                             1.09                          3996.03                             0.15
12/06/2013 10:37:39.472917	                      0.000000094                      0.000000998                      0.000000765                             16.7                             3.43                             1.09                          3996.64                             0.15
12/06/2013 10:37:40.472581	                      0.000000093                      0.000000996                      0.000000768                             16.7                             2.28                             1.15                          3996.64                             0.15
12/06/2013 10:37:41.472472	                      0.000000094                      0.000000998                      0.000000770                             16.7                             2.28                             1.15                          3996.64                             0.15
12/06/2013 10:37:42.472333	                      0.000000094                      0.000000998                      0.000000768                             16.8                             8.01                             1.03                          3996.64                             0.15
12/06/2013 10:37:43.472212	                      0.000000094                      0.000000998                      0.000000770                             16.8                             8.01                             1.03                          3996.64                             0.15
12/06/2013 10:37:44.738171	                      0.000000094                      0.000000998                      0.000000770                             16.8                             9.15                             1.03                          3996.64                             0.15
12/06/2013 10:37:45.737929	                      0.000000093                      0.000000998                      0.000000770                             16.8                             9.15                             1.03                          3996.03                             0.15
12/06/2013 10:37:46.737758	                      0.000000093                      0.000000996                      0.000000768                             16.8                            10.29                             1.03                          3996.64                             0.15
12/06/2013 10:37:47.737679	                      0.000000094                      0.000000996                      0.000000770                             16.8                             8.01                             0.91                          3996.64                             0.15
12/06/2013 10:37:48.737550	                      0.000000094                      0.000000998                      0.000000768                             16.8                             5.72                             1.15                          3996.64                             0.15
12/06/2013 10:37:49.737448	                      0.000000094                      0.000000998                      0.000000768                             16.8                             5.72                             1.15                          4276.79                             0.15
12/06/2013 10:37:50.737254	                      0.000000094                      0.000000998                      0.000000770                             16.8                             3.43                             0.97                          4997.02                             0.15
12/06/2013 10:37:51.738371	                      0.000000093                      0.000000996                      0.000000770                             16.8                            12.58                             0.91                          5997.40                             0.44
12/06/2013 10:37:52.739018	                      0.000000094                      0.000000996                      0.000000770                             16.8                            12.58                             1.15                          7996.33                             0.49
12/06/2013 10:37:53.739981	                      0.000000094                      0.000000998                      0.000000770                             16.9                             1.14                             1.15                          9499.65                             0.29
12/06/2013 10:37:54.739743	                      0.000000094                      0.000000998                      0.000000770                             16.9                             1.14                             1.15                         10997.48                             0.59
12/06/2013 10:37:55.739858	                      0.000000094                      0.000000996                      0.000000770                             16.9                            14.87                             1.15                         11999.69                             0.42
12/06/2013 10:37:56.740534	                      0.000000094                      0.000001010                      0.000000770                             16.9                            14.87                             1.15                         13499.35                             0.47
12/06/2013 10:37:57.740392	                      0.000000094                      0.000000998                      0.000000765                             16.9                             3.43                             1.15                         15000.83                             0.49
12/06/2013 10:37:58.740247	                      0.000000094                      0.000000998                      0.000000768                             16.8                             3.43                             1.15                         16499.88                             0.57
12/06/2013 10:37:59.740213	                      0.000000094                      0.000000998                      0.000000768                             16.8                            12.58                             1.15                         18001.98                             0.63
12/06/2013 10:38:00.740039	                      0.000000093                      0.000000998                      0.000000768                             16.8                            12.58                             1.15                         19068.89                             0.65
12/06/2013 10:38:01.739890	                      0.000000093                      0.000000998                      0.000000774                             16.8                            10.29                             0.97                         20003.35                             0.65
12/06/2013 10:38:02.739822	                      0.000000093                      0.000000998                      0.000000770                             16.8                            10.29                             0.97                         20003.35                             0.65
12/06/2013 10:38:03.740608	                      0.000000093                      0.000000998                      0.000000770                             16.8                          1007.09                             4.08                         20005.18                             0.65
12/06/2013 10:38:04.740535	                      0.000000094                      0.000000998                      0.000000768                             16.8                          2009.61                             2.38                         20005.18                             0.65
12/06/2013 10:38:05.740421	                      0.000000094                      0.000000998                      0.000000768                             16.8                          3292.51                             4.33                         20005.18                             0.65
12/06/2013 10:38:06.741299	                      0.000000093                      0.000000998                      0.000000770                             16.8                          4510.18                             7.87                         20005.18                             0.65
12/06/2013 10:38:07.741154	                      0.000000094                      0.000000998                      0.000000770                             16.8                          5794.23                             7.01                         20005.79                             0.65
12/06/2013 10:38:08.740978	                      0.000000094                      0.000000994                      0.000000770                             16.8                          7014.19                            10.80                         20005.79                             0.65
12/06/2013 10:38:09.740907	                      0.000000093                      0.000000998                      0.000000768                             16.8                          8294.80                            13.91                         20005.79                             0.65
12/06/2013 10:38:10.741753	                      0.000000093                      0.000000998                      0.000000768                             16.8                         10017.16                            14.58                         20005.79                             0.65
12/06/2013 10:38:11.742650	                      0.000000094                      0.000000996                      0.000000770                             16.8                         11519.79                            19.28                         20005.79                             0.65
12/06/2013 10:38:12.742528	                      0.000000093                      0.000000996                      0.000000770                             16.8                         12021.05                            12.81                         20005.79                             0.65
12/06/2013 10:38:13.742395	                      0.000000093                      0.000000998                      0.000000770                             16.8                         12522.31                            12.08                         20005.79                             0.65
12/06/2013 10:38:14.742226	                      0.000000093                      0.000000998                      0.000000770                             16.8                         13021.28                            12.26                         20005.79                             0.65
12/06/2013 10:38:15.742200	                      0.000000094                      0.000000998                      0.000000768                             16.8                         13801.78                            12.57                         20005.79                             0.65
12/06/2013 10:38:16.742099	                      0.000000094                      0.000000998                      0.000000770                             16.8                         14522.77                            17.39                         20005.79                             0.65
12/06/2013 10:38:17.742891	                      0.000000093                      0.000000996                      0.000000768                             16.8                         15024.03                            15.80                         20005.79                             0.65
12/06/2013 10:38:18.742772	                      0.000000093                      0.000000998                      0.000000768                             16.8                         15524.14                            14.89                         20005.79                             0.65
12/06/2013 10:38:19.742602	                      0.000000093                      0.000000998                      0.000000768                             16.8                         16524.37                            18.73                         20005.79                             0.65
12/06/2013 10:38:20.742477	                      0.000000093                      0.000000998                      0.000000768                             16.8                         17026.77                            17.27                         20005.79                             0.65
12/06/2013 10:38:21.743352	                      0.000000093                      0.000000996                      0.000000770                             16.8                         18030.44                            20.81                         20005.79                             0.65
12/06/2013 10:38:22.743286	                      0.000000093                      0.000000996                      0.000000770                             16.8                         18527.12                            18.67                         20005.79                             0.65
12/06/2013 10:38:23.743116	                      0.000000093                      0.000000998                      0.000000770                             16.8                         19528.49                            22.64                         20005.79                             0.65
12/06/2013 10:38:24.743988	                      0.000000093                      0.000000996                      0.000000765                             16.8                         20029.75                            21.17                         20005.79                             0.65
12/06/2013 10:38:25.743892	                      0.000000093                      0.000000996                      0.000000768                             16.8                         20529.86                            20.38                         20005.79                             0.65
12/06/2013 10:38:26.744754	                      0.000000093                      0.000000998                      0.000000770                             16.8                         21530.09                            25.63                         20005.79                             0.65
12/06/2013 10:38:27.744640	                      0.000000094                      0.000000998                      0.000000768                             16.8                         22031.35                            23.49                         20005.79                             0.65
12/06/2013 10:38:28.744504	                      0.000000093                      0.000000998                      0.000000768                             16.8                         22532.61                            22.94                         20005.79                             0.65
12/06/2013 10:38:29.745410	                      0.000000094                      0.000000998                      0.000000768                             16.8                         23032.73                            22.70                         20005.79                             0.65
12/06/2013 10:38:30.745262	                      0.000000094                      0.000000998                      0.000000770                             16.8                         23533.98                            27.52                         20005.79                             0.65
12/06/2013 10:38:31.745131	                      0.000000094                      0.000000996                      0.000000772                             16.8                         24533.07                            26.36                         20005.79                             0.65
12/06/2013 10:38:32.745008	                      0.000000094                      0.000000998                      0.000000768                             16.7                         25034.33                            25.63                         20005.79                             0.65
12/06/2013 10:38:33.745050	                      0.000000093                      0.000000998                      0.000000770                             16.7                         26034.56                            29.90                         20005.79                             0.65
12/06/2013 10:38:34.744755	                      0.000000094                      0.000001010                      0.000000768                             16.7                         26535.82                            28.25                         20005.79                             0.65
12/06/2013 10:38:35.744622	                      0.000000093                      0.000000998                      0.000000770                             16.7                         27035.93                            27.34                         20005.79                             0.65
12/06/2013 10:38:36.745477	                      0.000000093                      0.000000998                      0.000000768                             16.7                         27989.24                            31.73                         20005.79                             0.65
12/06/2013 10:38:37.746375	                      0.000000093                      0.000000998                      0.000000768                             16.7                         28536.27                            30.94                         20005.79                             0.65
12/06/2013 10:38:38.746259	                      0.000000094                      0.000000998                      0.000000770                             16.7                         29037.53                            30.88                         20005.79                             0.65
12/06/2013 10:38:39.746094	                      0.000000094                      0.000000996                      0.000000770                             16.7                         29538.79                            30.51                         20005.79                             0.65
12/06/2013 10:38:40.746006	                      0.000000093                      0.000000998                      0.000000768                             16.7                         30038.91                            30.45                         20005.79                             0.65
12/06/2013 10:38:41.745828	                      0.000000093                      0.000000998                      0.000000770                             16.7                         30539.02                            30.70                         20005.79                             0.65
12/06/2013 10:38:42.745708	                      0.000000093                      0.000000994                      0.000000768                             16.7                         31040.28                            31.55                         20005.79                             0.65
12/06/2013 10:38:43.746645	                      0.000000094                      0.000000994                      0.000000770                             16.7                         31993.59                            36.07                         20005.79                             0.65
12/06/2013 10:38:44.746538	                      0.000000093                      0.000000998                      0.000000765                             16.7                         32540.62                            35.82                         20005.79                             0.65
12/06/2013 10:38:45.746327	                      0.000000093                      0.000000998                      0.000000765                             16.7                         33040.74                            35.15                         20005.79                             0.65
12/06/2013 10:38:46.747194	                      0.000000093                      0.000001010                      0.000000770                             16.7                         33540.85                            34.79                         20005.79                             0.65
12/06/2013 10:38:47.747076	                      0.000000093                      0.000000996                      0.000000770                             16.7                         34545.66                            38.81                         20005.79                             0.65
12/06/2013 10:38:48.746949	                      0.000000093                      0.000000998                      0.000000768                             16.7                         35042.34                            37.17                         20005.79                             0.65
12/06/2013 10:38:49.747854	                      0.000000094                      0.000000998                      0.000000770                             16.8                         36041.42                            46.81                         20005.79                             0.65
12/06/2013 10:38:50.747794	                      0.000000093                      0.000000996                      0.000000768                             16.8                         36543.83                            40.03                         20005.79                             0.65
12/06/2013 10:38:51.748607	                      0.000000094                      0.000000998                      0.000000770                             16.8                         37043.94                            39.61                         20005.79                             0.65
12/06/2013 10:38:52.748492	                      0.000000093                      0.000000998                      0.000000770                             16.8                         37545.20                            39.73                         20005.79                             0.65
12/06/2013 10:38:53.748395	                      0.000000093                      0.000000998                      0.000000768                             16.8                         38046.46                            44.06                         20005.79                             0.65
12/06/2013 10:38:54.748195	                      0.000000093                      0.000000996                      0.000000768                             16.8                         39044.40                            43.03                         20005.79                             0.65
12/06/2013 10:38:55.748153	                      0.000000094                      0.000000998                      0.000000770                             16.8                         39545.66                            43.45                         20005.79                             0.65
12/06/2013 10:38:56.749112	                      0.000000094                      0.000000998                      0.000000770                             16.8                         39545.66                            40.89                         20005.79                             0.65
12/06/2013 10:38:57.748818	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40046.92                            41.50                         20005.79                             0.65
12/06/2013 10:38:58.748731	                      0.000000093                      0.000000998                      0.000000768                             16.8                         40046.92                            41.07                         20005.79                             0.65
12/06/2013 10:38:59.748612	                      0.000000094                      0.000000996                      0.000000768                             16.8                         40046.92                            40.89                         20005.79                             0.65
12/06/2013 10:39:00.748440	                      0.000000094                      0.000000996                      0.000000768                             16.8                         40046.92                            40.89                         20005.79                             0.65
12/06/2013 10:39:01.749351	                      0.000000094                      0.000001010                      0.000000770                             16.8                         40046.92                            40.89                         20005.79                             0.65
12/06/2013 10:39:02.749233	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.83                         20006.40                             0.65
12/06/2013 10:39:03.749082	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.83                         20006.40                             0.65
12/06/2013 10:39:04.749026	                      0.000000093                      0.000000998                      0.000000765                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:05.749899	                      0.000000094                      0.000000998                      0.000000768                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:06.750723	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:07.750716	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:08.750436	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.83                         20005.79                             0.65
12/06/2013 10:39:09.750420	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40046.92                            41.32                         20005.79                             0.65
12/06/2013 10:39:10.750265	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:11.751047	                      0.000000093                      0.000000996                      0.000000768                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:12.750973	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:13.751821	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:14.751678	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:15.751659	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:16.752539	                      0.000000094                      0.000000998                      0.000000772                             16.8                         40048.06                            40.71                         20503.85                             0.71
12/06/2013 10:39:17.753413	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         21004.34                             0.71
12/06/2013 10:39:18.753168	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         21504.23                             0.71
12/06/2013 10:39:19.753173	                      0.000000093                      0.000000998                      0.000000772                             16.7                         40048.06                            40.58                         22070.64                             0.76
12/06/2013 10:39:20.752945	                      0.000000093                      0.000000994                      0.000000768                             16.7                         40048.06                            40.58                         23000.83                             0.99
12/06/2013 10:39:21.753831	                      0.000000094                      0.000000996                      0.000000772                             16.7                         40048.06                            40.58                         23503.16                             0.80
12/06/2013 10:39:22.753731	                      0.000000093                      0.000000996                      0.000000772                             16.7                         40048.06                            40.58                         24003.66                             0.80
12/06/2013 10:39:23.753588	                      0.000000093                      0.000000996                      0.000000770                             16.7                         40048.06                            40.58                         24501.71                             0.85
12/06/2013 10:39:24.754474	                      0.000000094                      0.000000998                      0.000000765                             16.7                         40048.06                            40.58                         25003.43                             0.87
12/06/2013 10:39:25.754339	                      0.000000094                      0.000000998                      0.000000770                             16.7                         40048.06                            40.71                         25503.31                             0.87
12/06/2013 10:39:26.754168	                      0.000000094                      0.000000998                      0.000000772                             16.7                         40048.06                            40.71                         25953.15                             0.87
12/06/2013 10:39:27.754087	                      0.000000093                      0.000000998                      0.000000772                             16.8                         40048.06                            40.71                         26003.20                             0.87
12/06/2013 10:39:28.754026	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         26503.70                             0.99
12/06/2013 10:39:29.753829	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         26572.67                             0.99
12/06/2013 10:39:30.753655	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         27503.47                             0.95
... 14427 more lines ...
  578   Thursday, December 12, 2013, 11:14 Bevan MossConditioning StationStandard OperationTM2 HV Chase Electrical Test

While under vacuum Travis and I completed diagnostics of the HV chase. Majority of the lines showed OL at 1kV but there were the following "failures"

A to P @ 250V 716kOhm
A to Q @ 1kV 25.18MOhm
B to C with ohm meter 8Mohm @250V 830kOhm
B to D @ 1kV 15.57MOhm
C to D @1kV 16.18 MOhm
P to Q @1kV 1.069 GOhm
G to J with ohm meter dead short.

Ideally all of these values would be OL and they may improve or get worse when the source tray is installed depending on where the electrical contact is. I need to discuss with Friedhelm but I believe that as these values the module can still operate. Without changing the HV chase there is very little chance of improving these values.

  589   Thursday, January 30, 2014, 13:46 Travis CaveConditioning StationStandard OperationTM2no targetmodule move

TM#2 has been moved from the conditioning station to the south hot cell.

  601   Monday, February 17, 2014, 09:32 David WangConditioning StationRepairTM2 helium pressure test on TM2 tube heater +(D) water line.

I did the helium pressure test on Tube heater+ line this morning. The vacuum on CS and TM2 are very good. The base lake rate on leak detector was 1.7xE-7 atm.cc/sec. Base pressure was 0.0xE-4torr.  I applied helium to the "D"line .The test started from 30psi up to 80psi on both side "D" line.The base leak rate slightly changed to 1.9xE-7 atm.cc/sec during the test,but not base pressure. At this base leak rate level, No obvious leak had been found . See attachment pictures. The test will be repeated later when the base leak rate could be pumped into E -8 or E-9(the best) range.            

Attachment 1: 002.JPG
002.JPG
Attachment 2: 003.JPG
003.JPG
Attachment 3: 004.JPG
004.JPG
Attachment 4: 012.JPG
012.JPG
Attachment 5: 016.JPG
016.JPG
Attachment 6: 018.JPG
018.JPG
  602   Tuesday, February 18, 2014, 11:26 David WangConditioning StationRepairTM2 I stopped turbo pumps and disconnected vacuum system on TM 2 and CS

I stopped turbo pumps and disconnected vacuum system on TM2 and CS. The TM2 will be moved to SHC for C seal installation on "D" water block.

  603   Thursday, February 20, 2014, 09:45 Travis CaveConditioning StationStandard OperationTM2no targetmodule move

TM#2 has been moved from the conditioning station to the south hot cell.

  609   Tuesday, February 25, 2014, 10:00 David WangConditioning StationRepairTM2 helium pressure test on TM2 tube heater (+) water line with blank off(C-seal) installed on WB.

I did the helium pressure  test  on TM2 tube heater (+) water line  with blank off(C-seal) installed on  water block at CS.The leak detector was hooked directly to the top of the module this time. So base leak rate and base pressure were at the bottom scale on LD. 30 -80 psi helium was applied to the D lines(both side)  with10 psi   increasing each time. There is no any tiny response hasbeen found during the test. The lines are perfectly sealed. Also i sprayed the helium on the top of the service cap .All  air to vacuum seals on the top are good either. See attachment pictures.

Attachment 1: 004.JPG
004.JPG
Attachment 2: 005.JPG
005.JPG
Attachment 3: 006.JPG
006.JPG
Attachment 4: 007.JPG
007.JPG
Attachment 5: 008.JPG
008.JPG
Attachment 6: 009.JPG
009.JPG
Attachment 7: 010.JPG
010.JPG
Attachment 8: 011.JPG
011.JPG
Attachment 9: 017.JPG
017.JPG
Attachment 10: 019.JPG
019.JPG
  611   Wednesday, March 05, 2014, 10:07 Travis CaveConditioning StationStandard OperationTM2no targetmodule move

TM#2 with no target or source tray has been moved from the conditioning station to the north east silo. TM#1 with no target has been moved into the conditioning station.

  612   Thursday, March 06, 2014, 06:28 David WangConditioning StationMaintenanceTM1 TM1 had been moved from silo to CS

TM1 has been successfully moved from silo to CS. The CS vacuum system is connected  to TM1. Turbo pumps on TM1 and CS have been started yesterday afternoon . The starting of TM1 turbos was easy. The pumping down over night is good so far.

  614   Thursday, March 06, 2014, 12:59 David WangConditioning StationMaintenanceTM1 Restart TM1 and CS TPs

Restarted TM1 and CS turbo pumps after the power off. Everything is fine .

  615   Thursday, March 06, 2014, 14:12 David WangConditioning StationStandard OperationTM1 TM1 air to vacuum and water lines leak check at CS.

TM1 air to vacuum and water lines leak check at CS are finished this afternoon. The leak detector  is hooked directly to TM1 service cap so the base LR at LD is 0.0xE-9 atm.cc/sec. I sprayed helium to all air to vacuum seal on the service cap, also applied 70 psi to all water lines(except HS) for 2 minutes each. There is no any tiny response had been found on LD. So All TM1 water lines(except HS) and air to vacuum seals are leak free. The HS circuit can not be tested at this time since the VCR caps are not installed. The turbo pumps at CS and TM1 will be turned off before I leave.  See attachment pictures.

Attachment 1: 001.JPG
001.JPG
Attachment 2: 002.JPG
002.JPG
Attachment 3: 003.JPG
003.JPG
Attachment 4: 004.JPG
004.JPG
Attachment 5: 005.JPG
005.JPG
Attachment 6: 006.JPG
006.JPG
Attachment 7: 007.JPG
007.JPG
Attachment 8: 013.JPG
013.JPG
  627   Thursday, March 20, 2014, 08:19 Travis CaveConditioning StationStandard OperationTM1no targetmodule move

TM#1 with no target moved from the conditioning station to north west silo.

  633   Wednesday, March 26, 2014, 08:36 Travis CaveConditioning StationStandard OperationTM4Ta#42module move

TM#4 with Ta#42 has been moved from the south hot cell to the conditioning station.

  634   Thursday, March 27, 2014, 10:47 Travis CaveConditioning StationStandard OperationTM4Ta#42Electrical check

TM#4 with Ta#42 in the conditioning station under vacuum electrical check.

Attachment 1: TM#4_Ta42surf_electest_CS.PDF
TM#4_Ta42surf_electest_CS.PDF
  635   Monday, March 31, 2014, 13:22 Bevan MossConditioning StationStandard OperationTM4Ta #42HV conditioning

 TM4 with Ta#42 was HV conditioned to 35kV with the optics tray at 17.5kV. There was some vacuum response while ramping but well within normal. Attached is a screen shot and the associated data.

Attachment 1: 31032014_TM4_Ta#42_HV_Conditioning.txt
Time	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	TCS:IG1:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:DIC1:RDCOND [Mohm]	
03/31/2014 10:01:03.733174	                            11.44                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:04.732844	                            11.44                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:05.732769	                            12.58                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:06.732712	                            12.58                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:07.732465	                            12.58                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:08.733393	                            12.58                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:09.733515	                            12.58                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:10.734113	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:11.733990	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:12.733856	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:13.734748	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:14.734630	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:15.734460	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:16.734336	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:17.734235	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:18.735107	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:19.734959	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:20.734835	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:21.734750	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:22.844126	                            12.58                             0.18                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:23.844486	                            12.58                             0.18                             6.71                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:24.844315	                            12.58                             0.18                             6.71                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:25.846185	                            12.58                             0.18                             6.71                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:26.846055	                            12.58                             0.18                             6.71                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:27.845938	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:28.846887	                            11.44                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:29.846712	                            11.44                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:30.846596	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:31.846538	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:32.846330	                            10.29                             0.30                             7.32                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:33.847382	                            12.58                             0.18                             7.32                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:34.847056	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:35.846932	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:36.846800	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:37.846673	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:38.847547	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:40.104731	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:41.104567	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:42.104172	                            12.58                             0.18                             7.32                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:43.104164	                            12.58                             0.18                             7.32                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:44.104890	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:45.104770	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:46.104674	                            11.44                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:47.105620	                            11.44                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:48.106416	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:49.107534	                            12.58                             0.18                             6.71                             0.01                           BadVal                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:50.107142	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:51.107016	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:52.106907	                            11.44                             0.18                             6.71                             0.01                      0.000000541                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:53.106824	                            11.44                             0.18                             6.71                             0.01                      0.000000537                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:54.106672	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:55.106512	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:56.106402	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:57.106261	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:58.106140	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                           BadVal                           BadVal
03/31/2014 10:01:59.106045	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                           BadVal                           BadVal
03/31/2014 10:02:00.105877	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                           BadVal                           BadVal
03/31/2014 10:02:01.106805	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                           BadVal                           BadVal
03/31/2014 10:02:02.106632	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:03.106782	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:04.107410	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002549                           BadVal
03/31/2014 10:02:05.107394	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                      0.000002549                           BadVal
03/31/2014 10:02:06.108182	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:07.108063	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:08.107895	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:09.145507	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:10.195928	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:11.195508	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:12.195358	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:13.195230	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                      0.000002549                           BadVal
03/31/2014 10:02:14.196116	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:15.195989	                            12.58                             0.18                             6.71                             0.01                      0.000000539                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:16.195944	                            12.58                             0.18                             6.71                             0.01                      0.000000541                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:17.195738	                            12.58                             0.18                             6.71                             0.01                      0.000000541                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:18.195693	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:19.196508	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:20.196434	                            12.58                             0.18                             7.32                             0.01                      0.000000535                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:21.196308	                            12.58                             0.18                             7.32                             0.01                      0.000000535                           BadVal                      0.000002549                           BadVal
03/31/2014 10:02:22.196100	                            12.58                             0.18                             6.71                             0.01                      0.000000535                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:23.196019	                            12.58                             0.18                             6.71                             0.01                      0.000000537                           BadVal                      0.000002593                           BadVal
03/31/2014 10:02:24.283661	                            12.58                             0.18                             7.32                             0.01                      0.000000537                           BadVal                      0.000002571                           BadVal
03/31/2014 10:02:25.283865	                            12.58                             0.18                             7.32                             0.01                      0.000000535                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:26.283648	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:27.284460	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:28.284342	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002593                           BadVal
03/31/2014 10:02:29.285208	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001384                      0.000002571                           BadVal
03/31/2014 10:02:30.285140	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:31.285014	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:32.285861	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                           BadVal
03/31/2014 10:02:33.285706	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:34.284790	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:35.285462	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:36.285355	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:37.286202	                            12.58                             0.18                             7.32                             0.01                      0.000000537                      0.000001318                      0.000002549                           BadVal
03/31/2014 10:02:38.286087	                            12.58                             0.18                             7.32                             0.01                      0.000000535                      0.000001318                      0.000002549                           BadVal
03/31/2014 10:02:39.287229	                            12.58                             0.18                             7.32                             0.01                      0.000000537                      0.000001318                      0.000002571                           BadVal
03/31/2014 10:02:40.286833	                            12.58                             0.18                             7.32                             0.01                      0.000000537                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:41.286722	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002549                           BadVal
03/31/2014 10:02:42.286663	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:43.286636	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:44.286345	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:45.287322	                            12.58                             0.18                             7.32                             0.01                      0.000000537                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:46.287072	                            12.58                             0.18                             7.32                             0.01                      0.000000535                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:47.286970	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002571                           BadVal
03/31/2014 10:02:48.286830	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002593                           BadVal
03/31/2014 10:02:49.286701	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002571                           BadVal
03/31/2014 10:02:52.177616	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:53.178236	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:54.179135	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                           BadVal
03/31/2014 10:02:55.178964	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:56.182883	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002593                           BadVal
03/31/2014 10:02:57.183765	                            12.58                             0.18                             6.71                             0.01                      0.000000532                      0.000001362                      0.000002571                           BadVal
03/31/2014 10:02:58.183585	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                             10.5
03/31/2014 10:02:59.183583	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:00.183372	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:01.183341	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:02.183147	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:03.182950	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002571                             10.5
03/31/2014 10:03:04.183824	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                             10.5
03/31/2014 10:03:05.183703	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:06.183578	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002593                             10.5
03/31/2014 10:03:07.184451	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:08.184426	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:09.185200	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:10.185094	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:11.184972	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:12.184928	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:13.214901	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:14.215641	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:15.215439	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:16.215466	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:17.216192	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:18.216066	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:19.216939	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:20.216993	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:21.216687	                            12.58                             0.18                             6.71                             0.01                      0.000000532                      0.000001340                      0.000002593                             10.5
03/31/2014 10:03:22.216602	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                             10.5
03/31/2014 10:03:23.216432	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                             10.5
03/31/2014 10:03:24.217344	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:25.218233	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:26.218061	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002549                             10.5
03/31/2014 10:03:27.217964	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:28.217956	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:29.217839	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:30.217602	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:31.217432	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:32.217311	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:33.217306	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:34.218096	                            11.44                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:35.217929	                            11.44                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:36.217843	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002571                             10.5
03/31/2014 10:03:37.279743	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:38.374264	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:39.455103	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002549                             10.5
03/31/2014 10:03:40.455295	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002549                             10.5
03/31/2014 10:03:41.455156	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:42.455022	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002549                             10.5
03/31/2014 10:03:43.517929	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002549                             10.5
03/31/2014 10:03:44.605664	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002549                             10.5
03/31/2014 10:03:45.605769	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:03:46.605499	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002549                             10.5
03/31/2014 10:03:47.605372	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:48.605280	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:49.606125	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:50.606000	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:03:51.606922	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:52.606757	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:53.606653	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:54.606492	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:55.606422	                            12.58                             0.18                             6.71                             0.01                      0.000000552                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:56.606253	                            12.58                             0.18                             6.71                             0.01                      0.000000546                      0.000001340                      0.000002571                             10.5
03/31/2014 10:03:57.606119	                            12.58                             0.18                             6.71                             0.01                      0.000000546                      0.000001362                      0.000002615                             10.5
03/31/2014 10:03:58.606091	                            12.58                             0.18                             6.71                             0.01                      0.000000546                      0.000001340                      0.000002615                             10.5
03/31/2014 10:03:59.605889	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:00.605762	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:01.605614	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:02.605686	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:03.605398	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:04.605227	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:05.605108	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:06.604986	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:07.604864	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:08.604798	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:09.604612	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:10.604484	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:11.604377	                            12.58                             0.18                             7.32                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:12.604230	                            12.58                             0.18                             7.32                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.5
03/31/2014 10:04:13.605097	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:14.604980	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:15.604853	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:16.604721	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:17.604603	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:18.604509	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002571                             10.5
03/31/2014 10:04:19.604351	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:20.604276	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:21.604146	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:22.605062	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.6
03/31/2014 10:04:23.605929	                            12.58                             0.18                             6.71                             0.01                      0.000000546                      0.000001340                      0.000002593                             10.6
03/31/2014 10:04:24.605722	                            12.58                             0.18                             6.71                             0.01                      0.000000546                      0.000001318                      0.000002593                             10.6
03/31/2014 10:04:25.605584	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002615                             10.5
03/31/2014 10:04:26.605468	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001340                      0.000002615                             10.5
03/31/2014 10:04:27.616984	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001340                      0.000002615                             10.5
03/31/2014 10:04:28.687685	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:29.688084	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:30.687958	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:31.809569	                            12.58                             0.18                             7.32                             0.01                      0.000000539                      0.000001384                      0.000002593                             10.5
03/31/2014 10:04:32.809729	                            12.58                             0.18                             7.32                             0.01                      0.000000539                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:33.810786	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002593                             10.6
03/31/2014 10:04:34.810438	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:04:35.810414	                            12.58                             0.18                             7.32                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.6
03/31/2014 10:04:36.810188	                            12.58                             0.18                             7.32                             0.01                      0.000000543                      0.000001362                      0.000002593                             10.6
03/31/2014 10:04:37.810076	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001362                      0.000002593                             10.6
03/31/2014 10:04:38.867466	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:39.867804	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:40.886721	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:41.886686	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.5
03/31/2014 10:04:42.886424	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002615                             10.5
03/31/2014 10:04:43.886328	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:44.886195	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:45.886102	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:46.885922	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002615                             10.5
03/31/2014 10:04:47.885880	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002593                             10.6
03/31/2014 10:04:48.886695	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002593                             10.6
03/31/2014 10:04:49.886538	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002615                             10.5
03/31/2014 10:04:50.886467	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:51.886293	                            12.58                             0.18                             6.71                             0.01                      0.000000543                      0.000001362                      0.000002571                             10.5
03/31/2014 10:04:52.886184	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002615                             10.5
03/31/2014 10:04:53.886085	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002593                             10.5
03/31/2014 10:04:54.885916	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002593                             10.5
03/31/2014 10:04:55.980009	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.5
03/31/2014 10:04:56.979253	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.6
03/31/2014 10:04:57.978525	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002593                             10.6
03/31/2014 10:04:58.979433	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002593                             10.6
03/31/2014 10:04:59.979273	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:02.606530	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002571                             10.6
03/31/2014 10:05:03.605880	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002593                             10.6
03/31/2014 10:05:04.606708	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:05.606566	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:06.606480	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002593                             10.5
03/31/2014 10:05:07.606317	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002593                             10.5
03/31/2014 10:05:08.606192	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001318                      0.000002593                             10.5
03/31/2014 10:05:09.889941	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:05:11.695372	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002593                             10.6
03/31/2014 10:05:12.695678	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:13.743535	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:14.743435	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:15.743296	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:16.743524	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002549                             10.5
03/31/2014 10:05:17.743098	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:18.742924	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:19.742047	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:20.741695	                            11.44                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:21.741602	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:22.741410	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002549                             10.5
03/31/2014 10:05:23.741280	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:24.918398	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:25.918067	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:26.918881	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:27.918765	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:28.919631	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:29.919633	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:30.920406	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:31.920261	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.6
03/31/2014 10:05:34.936859	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.6
03/31/2014 10:05:35.936943	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002593                             10.6
03/31/2014 10:05:36.937848	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.6
03/31/2014 10:05:37.938715	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:38.938410	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:39.939247	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:40.939284	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:41.939003	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002593                             10.5
03/31/2014 10:05:42.938877	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:43.938828	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:44.938728	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.6
03/31/2014 10:05:45.938504	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:46.938451	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:47.938375	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:48.938143	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:49.939010	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001318                      0.000002615                             10.5
03/31/2014 10:05:50.938898	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:51.938765	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001318                      0.000002571                             10.5
03/31/2014 10:05:52.938622	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002593                             10.5
03/31/2014 10:05:53.938500	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:54.939556	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:55.939244	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:56.939118	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001340                      0.000002571                             10.5
03/31/2014 10:05:57.939019	                            12.58                             0.18                             6.71                             0.01                      0.000000541                      0.000001362                      0.000002571                             10.5
03/31/2014 10:05:58.938910	                            12.58                             0.18                             6.71                             0.01                      0.000000535                      0.000001362                      0.000002549                             10.5
03/31/2014 10:05:59.938928	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001362                      0.000002571                             10.5
03/31/2014 10:06:00.938613	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:01.938487	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.5
03/31/2014 10:06:02.938362	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:03.938273	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:04.938225	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:05.937985	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:06.937870	                            12.58                             0.18                             6.71                             0.01                      0.000000537                      0.000001340                      0.000002571                             10.5
03/31/2014 10:06:07.937756	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002549                             10.5
03/31/2014 10:06:08.937630	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001340                      0.000002571                             10.6
03/31/2014 10:06:09.937472	                            12.58                             0.18                             6.71                             0.01                      0.000000539                      0.000001362                      0.000002571                             10.6
... 11454 more lines ...
Attachment 2: 31032014_Ta#42_HV_conditioning.JPG
31032014_Ta#42_HV_conditioning.JPG
ELOG V2.9.2-2455