Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC, Page 109 of 138  Not logged in ELOG logo
ID Date Author Category Type Module Target/Number Subject
  589   Thursday, January 30, 2014, 13:46 Travis CaveConditioning StationStandard OperationTM2no targetmodule move

TM#2 has been moved from the conditioning station to the south hot cell.

  588   Wednesday, January 22, 2014, 15:20 Anders MjosSouth Hot-CellStandard Operation UC#8Target Inspection - post beam

The Target Assembly was inspected with Chad, Jens Henning and Anders today.

  • The Target Container was broken.
  • Material was deposited on the Heat Shield around the Target Center Block
  • Material was deposited on the IG-LIS source.
  • Electrical checks to ground (HS)
    • The Extraction Electrode passed the electrical check at 1000V
    • The Exit Electrode (c) held only 40V at 22 kOhm
    • The IG Electrode 1 (f) held 250V at 390 MOhm
    • The IG Electrode 2 (g) held only 40V at 22 kOhm
  • IG 1 and IG 2 both held 250V at 450 MOhm to Exit Electorde (c)
  • No spark marks were observed on the 9-pin connector

See photos of the inspection on DocuShare

  587   Wednesday, January 22, 2014, 15:00 Travis CaveSpent Target VaultStandard Operation UC#8Spent target move

UC#8 has been moved from the south hot cell to the vault storage. It was placed in pail 113 and placed in slot 8A of the vault. The field was 9.2mSv/hr upon removal from the south hot cell.

Attachment 1: Vault_Storage_January_22_2014.pdf
Vault_Storage_January_22_2014.pdf Vault_Storage_January_22_2014.pdf Vault_Storage_January_22_2014.pdf Vault_Storage_January_22_2014.pdf
  586   Wednesday, January 22, 2014, 10:51 David WangITERepair  Removed 4 shielding blocks located on top of preseperator in TH

Travis and I removed 4 shielding blocks located on top of pre-seperator  in TH. This is a job for ITE harp 9 re-installation after it  is repaired . The blocks move are successful.

  585   Tuesday, January 21, 2014, 14:32 Travis CaveSouth Hot-CellStandard OperationTM4no targetmodule move

TM#4 has been moved from the south hot cell to the north west silo.

  584   Monday, January 20, 2014, 14:37 Travis CaveITEStandard OperationTM4UC#8module move

TM#4 with UC#8 has been moved from the east target station to the south hot cell.

  583   Monday, January 20, 2014, 13:40 maicodallavalleSpent Target VaultMaintenance F-308Empty F-308s

Four empty F-308s just arrived back at Triumf. I moved them  from shipping to the Remote Handling Shop for service and inspection. I will work on them when not busy with my other shutdown work. ( Cyclotron work)

  582   Monday, January 20, 2014, 13:38 David WangITEStandard OperationTM4 DISCONNECTED TM4 IN ITE.

I DISCONNECTED TM4 IN ITE. ALL WATER LINES HAD BEEN PURGED OUT WITH PRESSURE AIR.

  581   Monday, January 20, 2014, 13:35 David WangITEStandard OperationTM4 5 shielding blocks had been moved out of ITE

5 SHIELDING BLOCKS HAD BEEN MOVED OUT OF ITE.AIR SAMPLE AND SWIPED FIRST BLOCK AND ITE PIT.NOTHING HAD BEEN FOUND ON ALPHA MONITOR AND OTHER TWO MONITORS.

  580   Thursday, January 16, 2014, 10:36 chad fisherSouth Hot-CellRepair  East Manipulator Repair

The repair/cable replacement on the east manipulator is now complete.

Yesterday's initail cable replacement went very well however, due to a minor glich, we were unable to test the tong movement until I was out of the hot cell. Tong did not fully close and felt like there was a "hard stop" at a repeatable spot in the  closing of the tong. Upon further investagation, I determined that the problem was definelty on the slave side.

I conducted a troublshooting exercise this morning to narrow down the problem. I quickly found that the new tong came from the manufacture with two incorrect fasteners (socket head cap screws) instead of set screws. As a result the tong was being kept from closing as the head of the socket head cap screws was interfering.

I replaced the SHCS was the set screws from the old tong. The tong now functions with full range of motion.

Jan. 15, 37 minutes in cell .26 mSv

Jan. 16, 16 minutes in cell (as I did some clean up of compressable waste) .05 mSv

Also, the inital repair utilized a prototype tool I designed (and with assistance from Maico, built). This tool made the repair much easier. I will be making small improvements to the design and issuing drawings to the vault and shop.

 

 

Attachment 1: Manip_repair_20140114.jpg
Manip_repair_20140114.jpg
Attachment 2: Manip_repair_20140115.jpg
Manip_repair_20140115.jpg
  579   Thursday, January 09, 2014, 11:07 chad fisherSouth Hot-CellMaintenance  Field Level

I have managed to reduce the field at the broken manipulator from 12 mSv/h to 400 uSv/h.

  578   Thursday, December 12, 2013, 11:14 Bevan MossConditioning StationStandard OperationTM2 HV Chase Electrical Test

While under vacuum Travis and I completed diagnostics of the HV chase. Majority of the lines showed OL at 1kV but there were the following "failures"

A to P @ 250V 716kOhm
A to Q @ 1kV 25.18MOhm
B to C with ohm meter 8Mohm @250V 830kOhm
B to D @ 1kV 15.57MOhm
C to D @1kV 16.18 MOhm
P to Q @1kV 1.069 GOhm
G to J with ohm meter dead short.

Ideally all of these values would be OL and they may improve or get worse when the source tray is installed depending on where the electrical contact is. I need to discuss with Friedhelm but I believe that as these values the module can still operate. Without changing the HV chase there is very little chance of improving these values.

  577   Monday, December 09, 2013, 14:47 David WangITEStandard OperationTM4 I moved 5 shielding blocks from block storage area to ITE.

I moved 5 shielding blocks to ITE. The ITE is configured to take proton beam.

  576   Monday, December 09, 2013, 13:15 Travis CaveSpent Target VaultStandard Operation Ta#41Spent target move

The spent Ta#41 target has been moved from the south hot cell to the spent target storage vault. It is an unnumbered pail (should be pail 112) and placed in spot 7A of the vault it had a reading of 536mSv/hr upon removal from the south hot cell. See attached PDF for vault details.

Attachment 1: Vault_Storage_December_9_2013.pdf
Vault_Storage_December_9_2013.pdf Vault_Storage_December_9_2013.pdf Vault_Storage_December_9_2013.pdf Vault_Storage_December_9_2013.pdf
  575   Friday, December 06, 2013, 15:09 Bevan MossConditioning StationStandard OperationTM2 TM2 no source tray 55kV 1 hour

Today 55kV was applied to TM2 and held for over 1 hour with the EINZEL at 27.5kV. There were 2 sparks and the current was unstable at this voltage but this test should be considered a success. Once again while bringing the voltage up the canbus continued to be a problem. After successfully passing the test I continued to raise the BIAS and EINZEL. A spark at 57kV tripped a controller for the vacuum and the canbus. As stated before I believe the module will reach 60kV and that there is an interaction between the EINZEL and the BIAS. I am not certain if that interaction is internal or external to the module. Attached is a screen shot and the dumped data.

Attachment 1: 06122013_TM2_No_source_Tray_55kV_1_hour.JPG
06122013_TM2_No_source_Tray_55kV_1_hour.JPG
Attachment 2: 06122013_TM2_No_Source_Tray_55kV_1_Hour.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:DIC1:RDCOND [Mohm]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
12/06/2013 10:34:30.138858	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:31.138402	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:32.138289	                      0.000000093                      0.000001010                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:33.138127	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:34.138033	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:35.137874	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:36.137749	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:37.137657	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:38.137550	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:39.138452	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:40.138322	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:41.138150	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:42.139015	                      0.000000094                      0.000000996                      0.000000768                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:43.138906	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:44.138797	                      0.000000093                      0.000000996                      0.000000765                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:45.138654	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:46.144533	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:47.144548	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:48.144363	                      0.000000093                      0.000000998                      0.000000768                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:49.144158	                      0.000000093                      0.000000996                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:50.144148	                      0.000000093                      0.000000996                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:51.144894	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:52.144785	                      0.000000093                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:53.144636	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:54.144483	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:55.157531	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:56.158254	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:57.158119	                      0.000000094                      0.000001032                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:58.157969	                      0.000000094                      0.000001010                      0.000000768                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:59.158877	                      0.000000093                      0.000000998                      0.000000768                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:00.159762	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:01.159615	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:03.306946	                      0.000000093                      0.000000996                      0.000000768                             16.9                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:04.307252	                      0.000000094                      0.000000998                      0.000000768                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:05.308070	                      0.000000094                      0.000000998                      0.000000768                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:06.308956	                      0.000000094                      0.000000994                      0.000000770                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:07.308826	                      0.000000094                      0.000000994                      0.000000770                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:08.308694	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:09.308573	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:10.309442	                      0.000000094                      0.000001010                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:11.309317	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:12.309197	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:13.309123	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:14.308964	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:15.309987	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:16.309785	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:17.309567	                      0.000000094                      0.000000996                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:18.422297	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:19.422322	                      0.000000094                      0.000000994                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:20.422292	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:21.422265	                      0.000000094                      0.000001010                      0.000000772                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:22.422985	                      0.000000094                      0.000001010                      0.000000772                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:23.532598	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:24.532696	                      0.000000094                      0.000000996                      0.000000772                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:25.700311	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:26.754388	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:27.754303	                      0.000000094                      0.000000996                      0.000000768                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:28.754164	                      0.000000094                      0.000000996                      0.000000768                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:29.808485	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:30.808903	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:31.892662	                      0.000000093                      0.000000996                      0.000000772                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:32.892649	                      0.000000094                      0.000000994                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:33.892524	                      0.000000094                      0.000000994                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:34.892399	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:36.59457	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:37.59452	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:38.58995	                      0.000000094                      0.000000998                      0.000000768                             16.8                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:39.58868	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:40.58702	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:41.59611	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:42.59451	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:43.59465	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:44.69481	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             8.54                             0.01
12/06/2013 10:35:45.70113	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             8.54                             0.01
12/06/2013 10:35:46.69968	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:47.69843	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:48.69730	                      0.000000093                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:49.69609	                      0.000000093                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:50.69501	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:51.70349	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:52.70327	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:53.71064	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:54.71157	                      0.000000094                      0.000000996                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:55.70854	                      0.000000093                      0.000000998                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:56.70728	                      0.000000093                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:57.70696	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:58.71465	                      0.000000094                      0.000000998                      0.000000772                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:59.71304	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:00.72214	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:01.72058	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:02.72037	                      0.000000094                      0.000000996                      0.000000765                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:03.71845	                      0.000000093                      0.000000996                      0.000000768                             16.8                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:36:04.71718	                      0.000000093                      0.000000996                      0.000000770                             16.8                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:36:05.71547	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:06.72545	                      0.000000094                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:07.72467	                      0.000000093                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:08.73208	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:09.73087	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:10.73946	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:11.74864	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:12.74666	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:13.75645	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:14.75641	                      0.000000093                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:15.75369	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:16.136319	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:17.136267	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:18.230037	                      0.000000094                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:19.229817	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:20.229681	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:21.229580	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:22.229431	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:23.229311	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:24.229201	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:25.229010	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:26.228930	                      0.000000094                      0.000000994                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:27.273591	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:28.273699	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:29.274782	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:30.274160	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:31.274279	                      0.000000094                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:32.274186	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:33.276910	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:34.276923	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:35.277751	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:36.277627	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:37.277496	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:38.277402	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:39.277265	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:40.277272	                      0.000000093                      0.000001010                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:41.278116	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:42.277876	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:43.277804	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:44.277667	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:45.277528	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:46.279324	                      0.000000094                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:47.279479	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:48.280171	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:49.280032	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:50.279918	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:51.280727	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:52.280665	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:53.280477	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:54.280361	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:55.280370	                      0.000000094                      0.000000994                      0.000000770                             16.7                            27.46                             0.06                             9.76                             0.01
12/06/2013 10:36:56.281267	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:57.281021	                      0.000000093                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:58.280911	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:59.280785	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:00.280647	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:01.281537	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:02.281408	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:03.281254	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:04.281106	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:05.281008	                      0.000000093                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:06.281889	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:07.281764	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:08.281734	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:09.281500	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:10.281385	                      0.000000094                      0.000000994                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:11.282277	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.76                             0.01
12/06/2013 10:37:12.282243	                      0.000000093                      0.000000998                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:13.282030	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:14.281905	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:15.281781	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:16.282607	                      0.000000093                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:17.282622	                      0.000000093                      0.000000998                      0.000000768                             16.9                             6.86                             1.03                             9.15                             0.01
12/06/2013 10:37:18.282434	                      0.000000094                      0.000000998                      0.000000770                             16.9                             6.86                             1.03                             1.22                             0.01
12/06/2013 10:37:19.282257	                      0.000000094                      0.000000998                      0.000000770                             16.9                             3.43                             1.03                             1.22                             0.01
12/06/2013 10:37:20.282499	                      0.000000094                      0.000000998                      0.000000770                             16.9                             4.57                             1.03                             1.83                             0.01
12/06/2013 10:37:21.283005	                      0.000000094                      0.000000998                      0.000000770                             16.9                             4.57                             1.03                           493.17                             0.01
12/06/2013 10:37:22.283870	                      0.000000093                      0.000000998                      0.000000770                             16.9                             4.57                             1.03                           993.05                             0.01
12/06/2013 10:37:23.283923	                      0.000000094                      0.000000998                      0.000000770                             16.9                             6.86                             0.91                          1494.16                             0.01
12/06/2013 10:37:24.283648	                      0.000000093                      0.000000996                      0.000000770                             16.9                             3.43                             1.15                          1494.16                             0.01
12/06/2013 10:37:25.283492	                      0.000000094                      0.000000998                      0.000000770                             16.9                            13.73                             1.15                          1994.04                             0.28
12/06/2013 10:37:26.283509	                      0.000000094                      0.000000998                      0.000000770                             16.9                            13.73                             1.15                          1994.04                             0.08
12/06/2013 10:37:27.283262	                      0.000000093                      0.000000998                      0.000000770                             16.8                             5.72                             0.85                          2494.54                             0.10
12/06/2013 10:37:28.283071	                      0.000000093                      0.000000998                      0.000000770                             16.8                             2.28                             0.97                          2995.04                             0.10
12/06/2013 10:37:29.282990	                      0.000000094                      0.000000998                      0.000000770                             16.8                             2.28                             0.97                          3495.53                             0.10
12/06/2013 10:37:30.282877	                      0.000000093                      0.000000998                      0.000000770                             16.8                            10.29                             0.97                          3994.81                             0.15
12/06/2013 10:37:31.283728	                      0.000000094                      0.000000996                      0.000000768                             16.8                             8.01                             0.91                          3994.81                             0.15
12/06/2013 10:37:32.283568	                      0.000000094                      0.000000998                      0.000000768                             16.8                             4.57                             1.15                          3996.03                             0.15
12/06/2013 10:37:33.283508	                      0.000000093                      0.000000998                      0.000000770                             16.8                             6.86                             1.15                          3996.03                             0.15
12/06/2013 10:37:34.283108	                      0.000000094                      0.000000998                      0.000000768                             16.8                             4.57                             1.03                          3996.03                             0.15
12/06/2013 10:37:35.283283	                      0.000000094                      0.000000998                      0.000000768                             16.8                             5.72                             1.03                          3996.03                             0.15
12/06/2013 10:37:36.284116	                      0.000000093                      0.000000994                      0.000000768                             16.8                             5.72                             1.09                          3996.03                             0.15
12/06/2013 10:37:37.283983	                      0.000000094                      0.000000998                      0.000000770                             16.8                             5.72                             1.09                          3996.64                             0.15
12/06/2013 10:37:38.283864	                      0.000000094                      0.000000998                      0.000000770                             16.7                             3.43                             1.09                          3996.03                             0.15
12/06/2013 10:37:39.472917	                      0.000000094                      0.000000998                      0.000000765                             16.7                             3.43                             1.09                          3996.64                             0.15
12/06/2013 10:37:40.472581	                      0.000000093                      0.000000996                      0.000000768                             16.7                             2.28                             1.15                          3996.64                             0.15
12/06/2013 10:37:41.472472	                      0.000000094                      0.000000998                      0.000000770                             16.7                             2.28                             1.15                          3996.64                             0.15
12/06/2013 10:37:42.472333	                      0.000000094                      0.000000998                      0.000000768                             16.8                             8.01                             1.03                          3996.64                             0.15
12/06/2013 10:37:43.472212	                      0.000000094                      0.000000998                      0.000000770                             16.8                             8.01                             1.03                          3996.64                             0.15
12/06/2013 10:37:44.738171	                      0.000000094                      0.000000998                      0.000000770                             16.8                             9.15                             1.03                          3996.64                             0.15
12/06/2013 10:37:45.737929	                      0.000000093                      0.000000998                      0.000000770                             16.8                             9.15                             1.03                          3996.03                             0.15
12/06/2013 10:37:46.737758	                      0.000000093                      0.000000996                      0.000000768                             16.8                            10.29                             1.03                          3996.64                             0.15
12/06/2013 10:37:47.737679	                      0.000000094                      0.000000996                      0.000000770                             16.8                             8.01                             0.91                          3996.64                             0.15
12/06/2013 10:37:48.737550	                      0.000000094                      0.000000998                      0.000000768                             16.8                             5.72                             1.15                          3996.64                             0.15
12/06/2013 10:37:49.737448	                      0.000000094                      0.000000998                      0.000000768                             16.8                             5.72                             1.15                          4276.79                             0.15
12/06/2013 10:37:50.737254	                      0.000000094                      0.000000998                      0.000000770                             16.8                             3.43                             0.97                          4997.02                             0.15
12/06/2013 10:37:51.738371	                      0.000000093                      0.000000996                      0.000000770                             16.8                            12.58                             0.91                          5997.40                             0.44
12/06/2013 10:37:52.739018	                      0.000000094                      0.000000996                      0.000000770                             16.8                            12.58                             1.15                          7996.33                             0.49
12/06/2013 10:37:53.739981	                      0.000000094                      0.000000998                      0.000000770                             16.9                             1.14                             1.15                          9499.65                             0.29
12/06/2013 10:37:54.739743	                      0.000000094                      0.000000998                      0.000000770                             16.9                             1.14                             1.15                         10997.48                             0.59
12/06/2013 10:37:55.739858	                      0.000000094                      0.000000996                      0.000000770                             16.9                            14.87                             1.15                         11999.69                             0.42
12/06/2013 10:37:56.740534	                      0.000000094                      0.000001010                      0.000000770                             16.9                            14.87                             1.15                         13499.35                             0.47
12/06/2013 10:37:57.740392	                      0.000000094                      0.000000998                      0.000000765                             16.9                             3.43                             1.15                         15000.83                             0.49
12/06/2013 10:37:58.740247	                      0.000000094                      0.000000998                      0.000000768                             16.8                             3.43                             1.15                         16499.88                             0.57
12/06/2013 10:37:59.740213	                      0.000000094                      0.000000998                      0.000000768                             16.8                            12.58                             1.15                         18001.98                             0.63
12/06/2013 10:38:00.740039	                      0.000000093                      0.000000998                      0.000000768                             16.8                            12.58                             1.15                         19068.89                             0.65
12/06/2013 10:38:01.739890	                      0.000000093                      0.000000998                      0.000000774                             16.8                            10.29                             0.97                         20003.35                             0.65
12/06/2013 10:38:02.739822	                      0.000000093                      0.000000998                      0.000000770                             16.8                            10.29                             0.97                         20003.35                             0.65
12/06/2013 10:38:03.740608	                      0.000000093                      0.000000998                      0.000000770                             16.8                          1007.09                             4.08                         20005.18                             0.65
12/06/2013 10:38:04.740535	                      0.000000094                      0.000000998                      0.000000768                             16.8                          2009.61                             2.38                         20005.18                             0.65
12/06/2013 10:38:05.740421	                      0.000000094                      0.000000998                      0.000000768                             16.8                          3292.51                             4.33                         20005.18                             0.65
12/06/2013 10:38:06.741299	                      0.000000093                      0.000000998                      0.000000770                             16.8                          4510.18                             7.87                         20005.18                             0.65
12/06/2013 10:38:07.741154	                      0.000000094                      0.000000998                      0.000000770                             16.8                          5794.23                             7.01                         20005.79                             0.65
12/06/2013 10:38:08.740978	                      0.000000094                      0.000000994                      0.000000770                             16.8                          7014.19                            10.80                         20005.79                             0.65
12/06/2013 10:38:09.740907	                      0.000000093                      0.000000998                      0.000000768                             16.8                          8294.80                            13.91                         20005.79                             0.65
12/06/2013 10:38:10.741753	                      0.000000093                      0.000000998                      0.000000768                             16.8                         10017.16                            14.58                         20005.79                             0.65
12/06/2013 10:38:11.742650	                      0.000000094                      0.000000996                      0.000000770                             16.8                         11519.79                            19.28                         20005.79                             0.65
12/06/2013 10:38:12.742528	                      0.000000093                      0.000000996                      0.000000770                             16.8                         12021.05                            12.81                         20005.79                             0.65
12/06/2013 10:38:13.742395	                      0.000000093                      0.000000998                      0.000000770                             16.8                         12522.31                            12.08                         20005.79                             0.65
12/06/2013 10:38:14.742226	                      0.000000093                      0.000000998                      0.000000770                             16.8                         13021.28                            12.26                         20005.79                             0.65
12/06/2013 10:38:15.742200	                      0.000000094                      0.000000998                      0.000000768                             16.8                         13801.78                            12.57                         20005.79                             0.65
12/06/2013 10:38:16.742099	                      0.000000094                      0.000000998                      0.000000770                             16.8                         14522.77                            17.39                         20005.79                             0.65
12/06/2013 10:38:17.742891	                      0.000000093                      0.000000996                      0.000000768                             16.8                         15024.03                            15.80                         20005.79                             0.65
12/06/2013 10:38:18.742772	                      0.000000093                      0.000000998                      0.000000768                             16.8                         15524.14                            14.89                         20005.79                             0.65
12/06/2013 10:38:19.742602	                      0.000000093                      0.000000998                      0.000000768                             16.8                         16524.37                            18.73                         20005.79                             0.65
12/06/2013 10:38:20.742477	                      0.000000093                      0.000000998                      0.000000768                             16.8                         17026.77                            17.27                         20005.79                             0.65
12/06/2013 10:38:21.743352	                      0.000000093                      0.000000996                      0.000000770                             16.8                         18030.44                            20.81                         20005.79                             0.65
12/06/2013 10:38:22.743286	                      0.000000093                      0.000000996                      0.000000770                             16.8                         18527.12                            18.67                         20005.79                             0.65
12/06/2013 10:38:23.743116	                      0.000000093                      0.000000998                      0.000000770                             16.8                         19528.49                            22.64                         20005.79                             0.65
12/06/2013 10:38:24.743988	                      0.000000093                      0.000000996                      0.000000765                             16.8                         20029.75                            21.17                         20005.79                             0.65
12/06/2013 10:38:25.743892	                      0.000000093                      0.000000996                      0.000000768                             16.8                         20529.86                            20.38                         20005.79                             0.65
12/06/2013 10:38:26.744754	                      0.000000093                      0.000000998                      0.000000770                             16.8                         21530.09                            25.63                         20005.79                             0.65
12/06/2013 10:38:27.744640	                      0.000000094                      0.000000998                      0.000000768                             16.8                         22031.35                            23.49                         20005.79                             0.65
12/06/2013 10:38:28.744504	                      0.000000093                      0.000000998                      0.000000768                             16.8                         22532.61                            22.94                         20005.79                             0.65
12/06/2013 10:38:29.745410	                      0.000000094                      0.000000998                      0.000000768                             16.8                         23032.73                            22.70                         20005.79                             0.65
12/06/2013 10:38:30.745262	                      0.000000094                      0.000000998                      0.000000770                             16.8                         23533.98                            27.52                         20005.79                             0.65
12/06/2013 10:38:31.745131	                      0.000000094                      0.000000996                      0.000000772                             16.8                         24533.07                            26.36                         20005.79                             0.65
12/06/2013 10:38:32.745008	                      0.000000094                      0.000000998                      0.000000768                             16.7                         25034.33                            25.63                         20005.79                             0.65
12/06/2013 10:38:33.745050	                      0.000000093                      0.000000998                      0.000000770                             16.7                         26034.56                            29.90                         20005.79                             0.65
12/06/2013 10:38:34.744755	                      0.000000094                      0.000001010                      0.000000768                             16.7                         26535.82                            28.25                         20005.79                             0.65
12/06/2013 10:38:35.744622	                      0.000000093                      0.000000998                      0.000000770                             16.7                         27035.93                            27.34                         20005.79                             0.65
12/06/2013 10:38:36.745477	                      0.000000093                      0.000000998                      0.000000768                             16.7                         27989.24                            31.73                         20005.79                             0.65
12/06/2013 10:38:37.746375	                      0.000000093                      0.000000998                      0.000000768                             16.7                         28536.27                            30.94                         20005.79                             0.65
12/06/2013 10:38:38.746259	                      0.000000094                      0.000000998                      0.000000770                             16.7                         29037.53                            30.88                         20005.79                             0.65
12/06/2013 10:38:39.746094	                      0.000000094                      0.000000996                      0.000000770                             16.7                         29538.79                            30.51                         20005.79                             0.65
12/06/2013 10:38:40.746006	                      0.000000093                      0.000000998                      0.000000768                             16.7                         30038.91                            30.45                         20005.79                             0.65
12/06/2013 10:38:41.745828	                      0.000000093                      0.000000998                      0.000000770                             16.7                         30539.02                            30.70                         20005.79                             0.65
12/06/2013 10:38:42.745708	                      0.000000093                      0.000000994                      0.000000768                             16.7                         31040.28                            31.55                         20005.79                             0.65
12/06/2013 10:38:43.746645	                      0.000000094                      0.000000994                      0.000000770                             16.7                         31993.59                            36.07                         20005.79                             0.65
12/06/2013 10:38:44.746538	                      0.000000093                      0.000000998                      0.000000765                             16.7                         32540.62                            35.82                         20005.79                             0.65
12/06/2013 10:38:45.746327	                      0.000000093                      0.000000998                      0.000000765                             16.7                         33040.74                            35.15                         20005.79                             0.65
12/06/2013 10:38:46.747194	                      0.000000093                      0.000001010                      0.000000770                             16.7                         33540.85                            34.79                         20005.79                             0.65
12/06/2013 10:38:47.747076	                      0.000000093                      0.000000996                      0.000000770                             16.7                         34545.66                            38.81                         20005.79                             0.65
12/06/2013 10:38:48.746949	                      0.000000093                      0.000000998                      0.000000768                             16.7                         35042.34                            37.17                         20005.79                             0.65
12/06/2013 10:38:49.747854	                      0.000000094                      0.000000998                      0.000000770                             16.8                         36041.42                            46.81                         20005.79                             0.65
12/06/2013 10:38:50.747794	                      0.000000093                      0.000000996                      0.000000768                             16.8                         36543.83                            40.03                         20005.79                             0.65
12/06/2013 10:38:51.748607	                      0.000000094                      0.000000998                      0.000000770                             16.8                         37043.94                            39.61                         20005.79                             0.65
12/06/2013 10:38:52.748492	                      0.000000093                      0.000000998                      0.000000770                             16.8                         37545.20                            39.73                         20005.79                             0.65
12/06/2013 10:38:53.748395	                      0.000000093                      0.000000998                      0.000000768                             16.8                         38046.46                            44.06                         20005.79                             0.65
12/06/2013 10:38:54.748195	                      0.000000093                      0.000000996                      0.000000768                             16.8                         39044.40                            43.03                         20005.79                             0.65
12/06/2013 10:38:55.748153	                      0.000000094                      0.000000998                      0.000000770                             16.8                         39545.66                            43.45                         20005.79                             0.65
12/06/2013 10:38:56.749112	                      0.000000094                      0.000000998                      0.000000770                             16.8                         39545.66                            40.89                         20005.79                             0.65
12/06/2013 10:38:57.748818	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40046.92                            41.50                         20005.79                             0.65
12/06/2013 10:38:58.748731	                      0.000000093                      0.000000998                      0.000000768                             16.8                         40046.92                            41.07                         20005.79                             0.65
12/06/2013 10:38:59.748612	                      0.000000094                      0.000000996                      0.000000768                             16.8                         40046.92                            40.89                         20005.79                             0.65
12/06/2013 10:39:00.748440	                      0.000000094                      0.000000996                      0.000000768                             16.8                         40046.92                            40.89                         20005.79                             0.65
12/06/2013 10:39:01.749351	                      0.000000094                      0.000001010                      0.000000770                             16.8                         40046.92                            40.89                         20005.79                             0.65
12/06/2013 10:39:02.749233	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.83                         20006.40                             0.65
12/06/2013 10:39:03.749082	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.83                         20006.40                             0.65
12/06/2013 10:39:04.749026	                      0.000000093                      0.000000998                      0.000000765                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:05.749899	                      0.000000094                      0.000000998                      0.000000768                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:06.750723	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:07.750716	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:08.750436	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.83                         20005.79                             0.65
12/06/2013 10:39:09.750420	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40046.92                            41.32                         20005.79                             0.65
12/06/2013 10:39:10.750265	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:11.751047	                      0.000000093                      0.000000996                      0.000000768                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:12.750973	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:13.751821	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:14.751678	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:15.751659	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:16.752539	                      0.000000094                      0.000000998                      0.000000772                             16.8                         40048.06                            40.71                         20503.85                             0.71
12/06/2013 10:39:17.753413	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         21004.34                             0.71
12/06/2013 10:39:18.753168	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         21504.23                             0.71
12/06/2013 10:39:19.753173	                      0.000000093                      0.000000998                      0.000000772                             16.7                         40048.06                            40.58                         22070.64                             0.76
12/06/2013 10:39:20.752945	                      0.000000093                      0.000000994                      0.000000768                             16.7                         40048.06                            40.58                         23000.83                             0.99
12/06/2013 10:39:21.753831	                      0.000000094                      0.000000996                      0.000000772                             16.7                         40048.06                            40.58                         23503.16                             0.80
12/06/2013 10:39:22.753731	                      0.000000093                      0.000000996                      0.000000772                             16.7                         40048.06                            40.58                         24003.66                             0.80
12/06/2013 10:39:23.753588	                      0.000000093                      0.000000996                      0.000000770                             16.7                         40048.06                            40.58                         24501.71                             0.85
12/06/2013 10:39:24.754474	                      0.000000094                      0.000000998                      0.000000765                             16.7                         40048.06                            40.58                         25003.43                             0.87
12/06/2013 10:39:25.754339	                      0.000000094                      0.000000998                      0.000000770                             16.7                         40048.06                            40.71                         25503.31                             0.87
12/06/2013 10:39:26.754168	                      0.000000094                      0.000000998                      0.000000772                             16.7                         40048.06                            40.71                         25953.15                             0.87
12/06/2013 10:39:27.754087	                      0.000000093                      0.000000998                      0.000000772                             16.8                         40048.06                            40.71                         26003.20                             0.87
12/06/2013 10:39:28.754026	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         26503.70                             0.99
12/06/2013 10:39:29.753829	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         26572.67                             0.99
12/06/2013 10:39:30.753655	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         27503.47                             0.95
... 14427 more lines ...
  574   Thursday, December 05, 2013, 14:57 David WangITEStandard OperationTM4  Connected TM4 in ITW

I connected TM4 in ITE. All turbo pumps have been started and wok fine including new TP3. Everything is good so far.

  573   Thursday, December 05, 2013, 14:55 David WangSouth Hot-CellStandard OperationTM4 Leak check on TM4 target heat shield

Chad and I leak checked TM4 heat shied water circuit at SHC. The pumping down was very good.Base leak rate 0.0xe-9 atm.cc/sec. BP 0.0xe-4torr. Sprayed helum twice on both VCR fittings.There is no response on leak detector.  The circuit is leak tight.

  572   Thursday, December 05, 2013, 12:51 Travis CaveSouth Hot-CellStandard OperationTM4UC#8 and no targetElectrical check

Electrical check was done on TM#4 without a target and with the UC#8 target on see attached PDF for results.

Attachment 1: TM#4_UC8_electest_SHC.PDF
TM#4_UC8_electest_SHC.PDF TM#4_UC8_electest_SHC.PDF
Attachment 2: TM#4_notarget_electest_SHC.PDF
TM#4_notarget_electest_SHC.PDF TM#4_notarget_electest_SHC.PDF
  571   Thursday, December 05, 2013, 12:04 Travis CaveITEStandard OperationTM4UC#8module move

TM#4 with UC#8 has been moved from the south hot cell to the east target station.

  570   Wednesday, December 04, 2013, 14:09 Travis CaveSouth Hot-CellStandard OperationTM4Ta#41Electrical check

Electrical check of TM#4 with Ta#41 post beam at the south hot cell. See PDF for details

Attachment 1: TM#4_Ta41_electest_SHC_PostBeam.PDF
TM#4_Ta41_electest_SHC_PostBeam.PDF
ELOG V2.9.2-2455