Message ID: 645     Entry time: Thursday, April 10, 2014, 14:03
Author: Bevan Moss 
Category: Conditioning Station 
Type: Standard Operation 
Module: TM3 
Target/Number: TiC#4 
Subject: HV conditioning 

 The TiC#4 target that is on TM3 was conditioned to 25kV today with the EINZEL lens at 12.5kV. There was one spark shortly after reaching 25kV that reset the bias PS and another one  after the module sat at 25kV for ~30 minutes. Attached is the strip tool data and screen shot. Prior to starting the conditioning the power on the chiller needed to by cycled as the VFD on the fans had tripped due to a recurring inrush problem.

Attachment 1: 10042014_Tm3_TiC#4_HV_conditioning.JPG  179 kB  | Show | Hide all
Attachment 2: 10042014_TM3_TiC#4_HV_conditioning.txt  2.198 MB  | Show | Hide all