Raymond Dubé | Routine | General | OLIS Surface Source broken Ionizer Coil |
We spent most of the day looking at OLIS to find out why the "Ionizer Coil" keeps breaking down, we found the following:
1. The FAN to cool R5 (ref: ISK4583D rev.7) a 25 Ohm 200W Resistor (2x50 ohm/100W ea.) was not ON, the nylon insulator (also the plastic tube across to the HV Terminal) was burnt and not holding the R5 resistor properly, I replaced the plastic insulator with a ceramic insulator.
Note that if the PE electrode is open it will charge up to the beam energy and start sparking. Also I used a red heatshrink tubing to prevent the BNC connector (it sits at Common) to touch the Cu pipe for the Plasma electrode water cooling.
2. Drawing for PE Polarity Switch: ISK4386D rev. 5
3. Drawing for EE:SS BOP (resistors & spark gap): ISK4584D rev. 1
4. Drawing for OLIS Surface & McroWave Source electrical diagram: ISK4583D rev. 7 |
Attachment 1: ISK4386D-rev5.pdf
|
Attachment 2: ISK4583D-rev7.pdf
|
Attachment 3: ISK4584D-rev1.pdf
|
Attachment 4: PE-R5-FAN_ON.jpg
|
|
|
482
|
Wed Aug 13 15:09:42 2014 |
Raymond Dubé | Routine | General | OLIS Attenuators #2 fixed, #1 gone! |
Today Probe group (Scott K.) installed the OLIS Attenuator, they fixed the vacuum leak on Attenuator #2, Marco M. asked them to remove Attenuator #1 because it is not needed and confusing for Ops;
Attenuator #1 was an experiment that Marco M. asked for, it was the same as Attenuator #2 but with 45 degrees offset, the results were not good and he decided to remove it. |
|
483
|
Tue Sep 16 11:55:28 2014 |
Raymond Dubé | Routine | General | MCIS info |
I found these files about the MCIS in Geoff folders in M:\ISIS\Geoff-110715\OLIS\SuperNanogan |
Attachment 1: Cart-Power1.pdf
|
Attachment 2: SuperNanogan_Control-R1.pdf
|
Attachment 3: Supernanogan_Interlocks-R1.pdf
|
|
484
|
Fri Oct 10 14:02:56 2014 |
Raymond Dube | Routine | General | Test with new Alga, ALPA 50W RF AMP |
We did a test yesterday with the new Alga Microwave RF AMP, model # ALPA 50 Watt, serial # 130684 to be used for the MCIS. We used the RF Generator from MISTIC and set the frequency to 13.80 Ghz, note that the RF Generator was/is limited to 16DB maxiumum RF output.
The RF cable that we used was from the 200W RF AMP, it has a 20DB SMA attenuator at the Generator end, so we could only get about 25 Watts maximum output. |
Attachment 1: ALPA-RF_AMP-50W.pdf
|
|
488
|
Thu Oct 23 10:52:21 2014 |
Brian Minato | Routine | General | ALGA Amplifier |
The ALGA amplifier and its signal generator have been turned off at the request of Controls. They have had communication issues and are looking for any recent changes. |
|
494
|
Thu Oct 30 22:44:45 2014 |
Keerthi Jayamanna | Routine | General | Mass scan 3 to 4 |
IOS mass scan if faulty. These is a manual scan from mass 3 to 4
Const22 = 0.04187 adjusted to mass = 4
A/q FC6 X Y
3.0075 8.14e-8 398 237
3.1222 4.93e-10 398 237
3.2064 6.24e-7 398 237
3.2613 1.05e-9 408 237
3.3395 2.29e-10 408 237
3.4072 5.6e-10 408 237
3.5089 3.36e-8 408 237
3.5600 1.4e-10 408 237
3.6069 1.86-9 408 237
3.6436 8.46e-10 408 237
3.7514 4.02e-10 418 237
3.8387 4.37e-9 418 237
3.8883 3.43e-10 418 237
3.9416 1e-10 418 237
4 1.1e-6 418 237 500 |
|
495
|
Thu Oct 30 23:37:58 2014 |
Keerthi Jayamanna | Routine | General | Mass scan 4 to 6 |
A/Q FC6
4 1.1e-6
4.25 8e-10
4.34 1.2e-9
4.42 5.5e-9
4.51 2.59e-9
4.58 1.7e-10
4.66 1.7e-10
4.74 1.7e-10
4.85 4.6e-10
5.0 1.36e-10
5.07 1.5e-10
5.13 2.69e-10
5.25 4.89e-10
5.33 9e-7
5.39 3.0e-10
5.56 3.3e-10
5.67 1.12e-9
5.7 5e-9
5.83 4e-10
5.92 2e-10
6.000 1.85e-7
|
|
496
|
Thu Oct 30 23:44:57 2014 |
Keerthi Jayamanna | Routine | General | OLIS Supernanogan mass scan 6 to 7.5 |
A/q FC6 (only current over 100pA)
6.0 1.85e-7
6.15 4.96e-10
6.23 2.4e-10
6.31 6.14e-10
6.39 2e-10
6.51 1.82e-9
6.90 2.7e-10
7.00 5e-8
7.1 4.6e-9
7.27 1e-10
7.5 3.32e-10
|
|
500
|
Wed Nov 12 13:32:47 2014 |
Raymond Dube | Routine | General | New in-line resistors for IOS:PE |
Today we replace the in-line resistors for the Plasma Electrode (PE) it was a 25 ohm 200W (2 x 50 Ohm 100W) with a 50 Ohm 200W (2 x 100 Ohm / 100W) also added the inductance coil.
This is R5 on drawing: ISK4583D rev. 10
This was done to reduce the power on R5
Note: We still need to make sure the the FAN is running to cool the resistors when the PE P/S is ON. |
Attachment 1: ISK4583D-rev10.pdf
|
|
504
|
Wed Nov 19 11:34:55 2014 |
Raymond Dube | Routine | General | OLIS Electrical diagram with 3 I.S. |
I updated the electrical Diagram for OLIS Faraday Cage with 3 Ion Source, ref: ISK4586D rev. 2
PS: Make sure that you do not connect both Bias P/S on same Ion Source ... |
Attachment 1: ISK4586D-rev2.pdf
|
|
506
|
Tue Nov 25 12:23:28 2014 |
Keerthi Jayamanna | Routine | General | 76Se+13 tune saved |
141125_1159_OLIS_76Se+13.snap is saved in reference directory.
El=3480/4303V
MCIS:YCB1=110
MCIS:XCB1=190
MCIS:CCB1=300
Frequency = 14.44765GHz
Amplitude = -10.880
TET FP= 9.8W
TWT RP = 1.8W
|
|
508
|
Mon Apr 20 08:09:03 2015 |
Brian Minato | Routine | General | OLIS Shutdown Update |
The OLIS 1 week shutdown has been completed (WP 2015-04-13-1).
General-
Y-Box insulators were inspected and look good. Beamline optics were inspected.
MWS-
The La disk was removed. Source housing was cleaned and re-asssembled with a beaker installed.
MCIS-
The cart was installed in the HV cage. Kr gas pack was installed on the cart and the transfer tube was opened up to MCIS vacuum.
SIS-
Source PE and EE assembly was removed and opened up for inspection. A new source was assembled (1/4 Ta tube and 0.040 Ta Oven & Ionizer wires) and installed. Lithium Nitrate Anhydrous (ALFA #13405 TR#205938) was inserted in the oven.
Additional details-
M:\OLIS\OFF LINE ION SOURCE\DOCUMENTS\Shutdown Work
OLIS MWS is currently running an producing 22Ne2+
|
|
511
|
Mon Sep 14 11:21:16 2015 |
Keerthi Jayamanna | Routine | General | 20Ne+2 beam saved |
20Ne+2 beam optics saved as 150914_1117_ios0iosfc6.snap |