641
|
Monday, April 07, 2014, 11:49 |
Travis Cave | South Hot-Cell | Standard Operation | TM3 | TiC#4 | Electrical check |
Electrical test of TM#3 with TiC#4 attached. See PDF. |
Attachment 1: TM#3_elec_test_TiC#4_surf.PDF
|
|
642
|
Monday, April 07, 2014, 14:13 |
chad fisher | South Hot-Cell | Standard Operation | TM3 | TiC#4 | TiC#4 installation |
TiC#4 has been installed onto TM3 |
643
|
Tuesday, April 08, 2014, 09:05 |
Travis Cave | South Hot-Cell | Standard Operation | TM3 | TiC#4 | module move |
TM#3 with TiC#4 has been moved from the south hot cell to the conditioning station. |
644
|
Wednesday, April 09, 2014, 11:10 |
David Wang | South Hot-Cell | Standard Operation | TM3 | | TM3 heat shield circuit leack check at SHC |
This Monday morning, Chad and I leak checked heat shielding circuit on TM3 with new target installed. The base LR on LD :0.0xE-9 atm.cc/sec, base pressure 0.0xE-4 torr. Chad sprayed helium twice on the VCR joints. No leak has been found. The circuit will be pressured with helium at CS. |
645
|
Thursday, April 10, 2014, 14:03 |
Bevan Moss | Conditioning Station | Standard Operation | TM3 | TiC#4 | HV conditioning |
The TiC#4 target that is on TM3 was conditioned to 25kV today with the EINZEL lens at 12.5kV. There was one spark shortly after reaching 25kV that reset the bias PS and another one after the module sat at 25kV for ~30 minutes. Attached is the strip tool data and screen shot. Prior to starting the conditioning the power on the chiller needed to by cycled as the VFD on the fans had tripped due to a recurring inrush problem. |
Attachment 1: 10042014_Tm3_TiC#4_HV_conditioning.JPG
|
|
Attachment 2: 10042014_TM3_TiC#4_HV_conditioning.txt
|
Time TCS:IG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:EL:RDVOL [V] TCS:EL:RDCUR [mA] TCS:BIAS:RDVOL [V] TCS:BIAS:RDCUR [uA] TCS:DIC1:RDCOND [Mohm]
04/10/2014 10:51:30.980156 0.000000961 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:31.979337 0.000000959 0.000005934 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:32.979181 0.000000959 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:33.979125 0.000000959 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:34.979530 0.000000957 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:35.979903 0.000000957 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:36.979928 0.000000959 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:37.979724 0.000000959 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:38.980475 0.000000957 0.000005890 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:39.980322 0.000000959 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:41.721703 0.000000957 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:42.720980 0.000000959 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:43.721829 0.000000959 0.000005912 BadVal BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:44.721709 0.000000959 0.000005934 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:45.721877 0.000000959 0.000005890 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:46.721604 0.000000959 0.000005912 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:47.721360 0.000000957 0.000005912 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:48.722248 0.000000959 0.000005890 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:49.722132 0.000000954 0.000005890 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:50.722206 0.000000954 0.000005912 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:51.722849 0.000000959 0.000005912 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:52.722691 0.000000959 0.000005934 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:53.723567 0.000000959 0.000005934 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:54.723552 0.000000957 0.000005912 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:55.723346 0.000000957 0.000005934 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:56.723198 0.000000957 0.000005934 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:57.723128 0.000000961 0.000005934 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:58.723980 0.000000961 0.000005912 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:51:59.723852 0.000000957 0.000005912 0.000003890 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:00.723765 0.000000959 0.000005912 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:01.723774 0.000000959 0.000005890 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:02.723712 0.000000959 0.000005912 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:03.723618 0.000000957 0.000005890 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:04.724220 0.000000957 0.000005890 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:05.724345 0.000000959 0.000005890 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:06.724243 0.000000957 0.000005890 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:07.723847 0.000000959 0.000005912 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:08.723737 0.000000957 0.000005912 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:09.734748 0.000000957 0.000005890 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:10.734468 0.000000961 0.000005912 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:11.734336 0.000000961 0.000005890 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:12.734202 0.000000957 0.000005934 0.000003912 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:13.735274 0.000000959 0.000005934 0.000003934 BadVal BadVal BadVal BadVal BadVal
04/10/2014 10:52:14.736049 0.000000959 0.000005890 0.000003934 6.10 BadVal BadVal BadVal BadVal
04/10/2014 10:52:15.735844 0.000000961 0.000005890 0.000003934 6.10 BadVal BadVal BadVal BadVal
04/10/2014 10:52:16.735707 0.000000959 0.000005912 0.000003934 6.71 BadVal BadVal BadVal BadVal
04/10/2014 10:52:17.735550 0.000000959 0.000005912 0.000003934 6.71 BadVal BadVal BadVal BadVal
04/10/2014 10:52:18.735469 0.000000957 0.000005912 0.000003890 6.10 0.01 BadVal BadVal BadVal
04/10/2014 10:52:19.735397 0.000000959 0.000005890 0.000003934 6.10 0.01 BadVal BadVal BadVal
04/10/2014 10:52:20.736220 0.000000959 0.000005912 0.000003912 6.10 0.01 BadVal BadVal BadVal
04/10/2014 10:52:21.737118 0.000000961 0.000005912 0.000003934 6.10 0.01 BadVal BadVal BadVal
04/10/2014 10:52:22.736946 0.000000961 0.000005912 0.000003912 6.10 0.01 BadVal BadVal BadVal
04/10/2014 10:52:23.736842 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 BadVal BadVal
04/10/2014 10:52:24.736718 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 BadVal BadVal
04/10/2014 10:52:25.736582 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 BadVal BadVal
04/10/2014 10:52:26.735970 0.000000959 0.000005912 0.000003912 6.71 0.01 18.31 BadVal BadVal
04/10/2014 10:52:27.764214 0.000000959 0.000005912 0.000003934 6.71 0.01 18.31 BadVal BadVal
04/10/2014 10:52:28.764296 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 BadVal
04/10/2014 10:52:29.764046 0.000000959 0.000005912 0.000003912 6.10 0.01 18.31 0.18 BadVal
04/10/2014 10:52:30.763942 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 BadVal
04/10/2014 10:52:31.764595 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 BadVal
04/10/2014 10:52:32.764669 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 BadVal
04/10/2014 10:52:33.765611 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 BadVal
04/10/2014 10:52:34.765460 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 BadVal
04/10/2014 10:52:35.765345 0.000000961 0.000005912 0.000003934 6.10 0.01 17.16 0.18 BadVal
04/10/2014 10:52:36.765196 0.000000959 0.000005912 0.000003912 6.71 0.01 17.16 0.18 BadVal
04/10/2014 10:52:37.765304 0.000000959 0.000005890 0.000003934 6.71 0.01 17.16 0.18 BadVal
04/10/2014 10:52:38.765944 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 BadVal
04/10/2014 10:52:39.765800 0.000000959 0.000005890 0.000003956 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:40.765665 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:41.766003 0.000000954 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:42.766445 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:43.767346 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:44.767203 0.000000961 0.000005890 0.000003890 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:52:45.767105 0.000000959 0.000005890 0.000003890 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:52:46.766994 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:47.766939 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:48.851745 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:49.877773 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:50.877440 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:51.877267 0.000000959 0.000005912 0.000003934 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:52:52.877165 0.000000959 0.000005890 0.000003934 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:52:53.877016 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:54.877020 0.000000959 0.000005890 0.000003912 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:52:55.876788 0.000000959 0.000005890 0.000003934 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:52:56.876639 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:57.876545 0.000000961 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:52:58.876493 0.000000961 0.000005912 0.000003912 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:52:59.876303 0.000000959 0.000005890 0.000003934 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:53:00.876207 0.000000954 0.000005890 0.000003934 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:53:01.876057 0.000000957 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:02.973167 0.000000959 0.000005912 0.000003912 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:53:04.127504 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:05.245403 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:06.245504 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:07.246554 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:08.246272 0.000000961 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:09.246145 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:10.245957 0.000000959 0.000005890 0.000003868 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:11.245855 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:12.246803 0.000000959 0.000005912 0.000003934 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:53:13.246602 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:14.246883 0.000000957 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:15.247430 0.000000957 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:16.248242 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:17.248123 0.000000957 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:18.248018 0.000000959 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:19.247819 0.000000959 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:20.248760 0.000000957 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:21.248576 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:22.248523 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:23.248379 0.000000959 0.000005890 0.000003868 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:24.248306 0.000000961 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:25.248120 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:26.247992 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:27.247865 0.000000957 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:28.247725 0.000000957 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:29.248587 0.000000957 0.000005912 0.000003868 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:53:30.248506 0.000000959 0.000005912 0.000003912 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:53:31.477726 0.000000961 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:32.510989 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:33.570288 0.000000961 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:34.569946 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:35.569810 0.000000954 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:36.569693 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:37.569517 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:38.570683 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:39.570275 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:40.570189 0.000000957 0.000005890 0.000003912 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:53:41.663248 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:42.796751 0.000000961 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:43.796790 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:53:44.796660 0.000000961 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:53:45.797531 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:53:46.797366 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:47.963516 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:48.963095 0.000000959 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:49.964000 0.000000957 0.000005890 0.000003890 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:53:50.963885 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:51.963082 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:52.962598 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:53.963488 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:54.964455 0.000000959 0.000005890 0.000003934 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:53:55.964257 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:56.964088 0.000000957 0.000005890 0.000003934 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:53:57.964030 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:58.964837 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:53:59.964711 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:00.964585 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:01.964460 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:02.964438 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:03.965278 0.000000959 0.000005890 0.000003912 6.10 0.01 18.31 0.18 13.2
04/10/2014 10:54:04.965134 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:06.114629 0.000000959 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:07.114842 0.000000959 0.000005890 0.000003934 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:54:08.114859 0.000000959 0.000005890 0.000003912 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:54:09.115601 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:11.95567 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:12.95203 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:13.95062 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:14.94930 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:15.95034 0.000000954 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:16.94756 0.000000957 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:17.94640 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:18.94482 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:19.94499 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:20.94191 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:21.94057 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:22.94970 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:23.94867 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:24.95670 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:25.95555 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:26.95473 0.000000959 0.000005934 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:27.95345 0.000000957 0.000005890 0.000003868 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:28.95171 0.000000957 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:29.156966 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:30.219271 0.000000954 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:31.218823 0.000000959 0.000005868 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:32.218700 0.000000954 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:33.218572 0.000000959 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:34.219484 0.000000957 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:35.219324 0.000000954 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:36.219155 0.000000954 0.000005890 0.000003912 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:54:37.219030 0.000000954 0.000005890 0.000003934 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:54:38.218939 0.000000957 0.000005868 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:39.219905 0.000000957 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:40.219644 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:41.219569 0.000000957 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:42.219471 0.000000954 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:43.219276 0.000000954 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:44.220207 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:45.226449 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:46.225901 0.000000957 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:47.225793 0.000000957 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:48.225688 0.000000959 0.000005890 0.000003912 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:54:49.237062 0.000000954 0.000005890 0.000003912 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:54:50.237414 0.000000954 0.000005868 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:51.237318 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:52.237170 0.000000957 0.000005868 0.000003868 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:54:53.237085 0.000000959 0.000005890 0.000003890 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:54:54.237035 0.000000957 0.000005890 0.000003912 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:54:55.236818 0.000000959 0.000005890 0.000003912 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:54:56.236684 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:57.236508 0.000000957 0.000005868 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:54:58.236539 0.000000957 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:54:59.237346 0.000000954 0.000005934 0.000003934 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:00.238278 0.000000957 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:01.238061 0.000000957 0.000005868 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:02.237902 0.000000957 0.000005868 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:03.237965 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:04.238630 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:05.239504 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:06.239438 0.000000954 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:07.239297 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:08.240205 0.000000959 0.000005890 0.000003890 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:55:09.240127 0.000000959 0.000005890 0.000003890 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:55:10.240229 0.000000954 0.000005890 0.000003912 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:55:11.240963 0.000000957 0.000005890 0.000003868 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:12.242313 0.000000959 0.000005868 0.000003868 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:13.242643 0.000000959 0.000005890 0.000003868 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:14.243588 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:15.243253 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:16.243399 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:17.243056 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:18.243878 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:19.244834 0.000000954 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:20.245696 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:21.245500 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:22.245413 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:23.245446 0.000000954 0.000005912 0.000003912 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:55:24.246172 0.000000954 0.000005912 0.000003912 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:55:25.247101 0.000000954 0.000005912 0.000003912 6.71 0.01 18.31 0.18 13.1
04/10/2014 10:55:26.246944 0.000000957 0.000005912 0.000003890 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:55:27.246745 0.000000957 0.000005890 0.000003956 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:28.246707 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:29.247622 0.000000957 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:30.247664 0.000000957 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:31.247309 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:32.247107 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:33.247041 0.000000959 0.000005890 0.000003868 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:34.247898 0.000000957 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:35.248757 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:36.248622 0.000000957 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:37.248512 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:38.248407 0.000000954 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:39.248278 0.000000954 0.000005868 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:40.248215 0.000000954 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:41.248104 0.000000959 0.000005912 0.000003912 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:55:42.247859 0.000000959 0.000005868 0.000003890 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:55:43.247775 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:44.248699 0.000000959 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:55:45.248591 0.000000954 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:46.248414 0.000000954 0.000005890 0.000003934 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:55:47.248231 0.000000954 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:48.248200 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:50.356306 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:51.356770 0.000000954 0.000005934 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:52.356658 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:53.356479 0.000000957 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:55.692384 0.000000959 0.000005912 0.000003868 6.71 0.01 18.31 0.18 13.1
04/10/2014 10:55:56.693040 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:57.693001 0.000000959 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:58.692827 0.000000959 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:55:59.692705 0.000000954 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:00.693597 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:01.693469 0.000000959 0.000005912 0.000003934 6.10 0.01 18.31 0.18 13.1
04/10/2014 10:56:02.693310 0.000000959 0.000005890 0.000003934 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:56:03.693156 0.000000959 0.000005890 0.000003934 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:56:04.693036 0.000000959 0.000005890 0.000003934 6.10 0.01 18.31 0.18 13.2
04/10/2014 10:56:05.692994 0.000000957 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:56:06.692862 0.000000957 0.000005890 0.000003934 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:56:07.693748 0.000000954 0.000005912 0.000003912 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:56:08.693600 0.000000954 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:56:09.694444 0.000000957 0.000005868 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:56:10.695298 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:56:11.695160 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:56:12.695091 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:56:13.694987 0.000000954 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:56:14.694827 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.2
04/10/2014 10:56:15.694742 0.000000959 0.000005912 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:16.694531 0.000000959 0.000005934 0.000003890 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:56:17.694420 0.000000959 0.000005890 0.000003890 6.71 0.01 17.16 0.18 13.1
04/10/2014 10:56:18.694323 0.000000957 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:19.694196 0.000000954 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:20.694200 0.000000954 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:21.693936 0.000000957 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:22.693796 0.000000957 0.000005890 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:23.693687 0.000000959 0.000005890 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:24.693613 0.000000957 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:25.693505 0.000000959 0.000005868 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:26.693314 0.000000957 0.000005868 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:27.693140 0.000000957 0.000005890 0.000003890 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:28.693023 0.000000957 0.000005912 0.000003934 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:29.692952 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:30.693831 0.000000954 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:31.693711 0.000000957 0.000005934 0.000003956 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:32.694613 0.000000959 0.000005912 0.000003912 6.10 0.01 17.16 0.18 13.1
04/10/2014 10:56:33.694463 0.000000957 0.000005912 0.000003890 6.71 0.01 17.16 0.18 13.2
04/10/2014 10:56:34.694275 0.000000957 0.000005868 0.000003890 6.71 0.01 17.16 0.18 13.2
... 7596 more lines ...
|
646
|
Friday, April 11, 2014, 11:35 |
David Wang | Conditioning Station | Standard Operation | TM3 | | Helium pressure test on TM3 HS water line with new Ta target. at CS |
The helium pressure test on TM3 HS water line with new Ta target is finished at CS. The circuit is leak tight.. No any response on LD. See pictures. |
Attachment 1: 027.JPG
|
|
Attachment 2: 026.JPG
|
|
Attachment 3: 025.JPG
|
|
Attachment 4: 022.JPG
|
|
Attachment 5: 024.JPG
|
|
Attachment 6: 023.JPG
|
|
650
|
Tuesday, April 15, 2014, 08:53 |
Travis Cave | ITE | Standard Operation | TM3 | TiC#4 | module move |
TM#3 with TiC#4 has been moved from the conditioning station to the east target station. |
651
|
Wednesday, April 16, 2014, 10:16 |
Anders Mjos | ITW | Development | TM3 | Ta#42 | Flow meters installed on Heat Shield and Coil water return |
Anders Mjos wrote: |
David W. has installed two SST Proteus flow meters, model OV7006FTA32, on ITW Heat Shield and Coil. The flow meters are connected to a power supply and a data logger in the electrical room.
The Heat Shield flow meter has SN 00278112 and is on the Black wire pairs and connected to CH3 & CH4 on the logger.
The Coil flow meter has SN 00278113 and is on the Green wire pairs and connected to CH1 & CH2 on the logger.
The first channel (CH1, CH3) is temperature in degrees Celcius and the second channel (CH2, CH4) is flow rate in liters per minute.
A camera has been placed on the logger.
Flow rates today (2014-04-04):
HS 8.2 - 8.3 lpm
COIL 8.0 - 8.1 lpm
Calibration sheets
UPDATE 2014-04-11: Corrected HS to CH3 & CH4.
|
PDFs of temperature and flow traces are available on DocuShare
Monday, April 28, 2014, 09:27. p+ off since 8:20
|
Temp [C] |
Flow [lpm] |
HS |
28.3 |
8.38 |
COIL |
26.3 |
8.01 |
Tuesday, April 29, 2014, 09:28: p+ 30 uA
|
Temp [C] |
Flow [lpm] |
HS |
31.7 |
8.40 |
COIL |
27.6 |
8.13 |
Monday, May 05, 2014, 10:49: p+ off since 8:39
(Downloaded data and updated traces on DocuShare)
|
Temp [C] |
Flow [lpm] |
HS |
27.1 |
8.47 |
COIL |
26.6 |
8.11 |
Wednesday, May 14, 2014
(Downloaded data and updated traces on DocuShare)
|
Temp [C] |
Flow [lpm] |
HS |
33.5 |
7.7 |
COIL |
29.0 |
7.5 |
|
654
|
Monday, May 05, 2014, 10:40 |
Travis Cave | ITE | Standard Operation | TM3 | TiC#4 | module move |
TM#3 with TiC#4 has been moved from the east station to the south west silo. |
655
|
Monday, May 05, 2014, 13:05 |
David Wang | ITE | Repair | TM3 | | ITE target module flange seal has been replaced. |
ITE target module flange seal has been replaced.The flan surface and the o-ring groove have been cleaned with Acetone before the new seal is installed. See attached picture. |
Attachment 1: 004.JPG
|
|
Attachment 2: 008.JPG
|
|
Attachment 3: 008.JPG
|
|
Attachment 4: 007.JPG
|
|
656
|
Monday, May 05, 2014, 13:11 |
David Wang | ITE | Repair | TM3 | | ITE Entrance module has been disconnected. |
ITE entrance module has been disconnected and the lifting yoke is installed for module move. See attached pictures. |
Attachment 1: 011.JPG
|
|
Attachment 2: 025.JPG
|
|
Attachment 3: 033.JPG
|
|
Attachment 4: 035.JPG
|
|
Attachment 5: 032.JPG
|
|
658
|
Wednesday, May 07, 2014, 10:08 |
David Wang | ITE | Repair | TM3 | | ITE entrance module flange seal had been replaced. |
ITE entrance module flange seal had been replaced yesterday.The flange and the seal groove were cleaned with Acetone before the new seal is installed. See pictures |
Attachment 1: 001.JPG
|
|
Attachment 2: 002.JPG
|
|
Attachment 3: 003.JPG
|
|
Attachment 4: 004.JPG
|
|
Attachment 5: 005.JPG
|
|
Attachment 6: 006.JPG
|
|
Attachment 7: 007.JPG
|
|
659
|
Wednesday, May 07, 2014, 10:15 |
David Wang | ITE | Repair | TM3 | | ITE TM3, entrance module and BL2A3 window flange seals leak check.. |
ITE TM3, entrance module, and 2A3 window flange seals have been leak checked this morning after 2 new seals replacement.The LD base leak rate was 0.0xE-9 atm.cc/sec, base pressure was 0.0 XE-4 Torr. I sprayed lots helium around the TM3, entrance module and 2A3 flange seals. No any response had been found on LD during the spraying. All three flanges are sealed perfectly now. |
660
|
Wednesday, May 14, 2014, 19:01 |
Grant Minor | ITE | Maintenance | TM3 | | HV short inspection at ITE |
Friedhelm Ames commented to me that there appears to be a short between High Voltage and Ground at TM3 at ITE.
Friedhelm, Anders and I initiated a survey by Andrew from RPG, and entered the Target Hall at approximately 5pm to visually assess the HV cover at the MAA. There was no clear indication of a problem. We opted to wait for David to return as we weren't sure exactly what we were looking for.
Friedhelm and Anders confirmed in the Electrical Room that the short is in the Target Hall. |
661
|
Thursday, May 15, 2014, 14:38 |
David Wang | ITE | Repair | TM3 | TM3 | Bias short on ITE |
Anders and I opened the HV cover in ITE and did a visual check inside ITE HV cover and top of TM3.Bill was with us and took the pictures. There was nothing obviously wrong when we opened the HV cover in ITE. We disconnected TM3 high current cables from ITE. Then we did an electrical check on TM3.The TM3 was good and passed megga test (465Mohm at 500V). The module was good and was separated electrically from the ITE at that moment. Then, we went back to electrical room and measured the resistance between bias and ground with ground bar opened and power supply disconnect. It was still shorted at that moment .We thought the short is located inside HV chase between electrical room and ITE. Then, we went back to ITE again and reconnected TM3 back to ITE. We wiped two blue nylon insulators between bias and ground, and no obviously spark track or dirty on them. We put HV cover back in ITE locked area, and went back to electrical room again.We decided to do a final electrical check there. We thought the short should be still there and we just want to confirm it . But this time the short is gone. Everything goes back to normal. The short disappeared and We test bias to 5KV and the current looks normal now. |
684
|
Tuesday, June 24, 2014, 11:12 |
Travis Cave | South Hot-Cell | Standard Operation | TM3 | TiC#4 | module move |
TM#4 with TiC#4 has been moved from the east target station to the south hot cell. |
686
|
Tuesday, June 24, 2014, 11:58 |
Travis Cave | South Hot-Cell | Standard Operation | TM3 | TiC#4 | Electrical check |
Electrical check of the TiC#4 on TM#3 post beam at the south hot cell, see attached PDF for details |
Attachment 1: TM3_TiC4_elec_chk_SHC_postbeam.PDF
|
|
687
|
Tuesday, June 24, 2014, 15:14 |
Anders Mjos | South Hot-Cell | Standard Operation | TM3 | TiC#4 | Conductor insulator broken close to right TGHT terminal |
When the Containment Box was opened today by Chad for a target change, we found the conductor insulator block B (ITD0054) to be broken close to the right TGHT terminal. Chad was nevertheless able to remove the target. See DocuShare and attached file for photos.
An attempt to replace the insulator will be made tomorrow with a spare.
A small sticky piece, likely off plastic material, was found next to the left main source tray insulator. The piece was removed from the Containment Box. See link above and attachment for photos. |
Attachment 1: TiC#4_Broken_Insulator.pdf
|
|
688
|
Tuesday, June 24, 2014, 15:45 |
Anders Mjos | South Hot-Cell | Standard Operation | TM3 | TiC#4 | Ground Electrode and Extraction Electrode dirty after last run |
See attached pdf and DocuShare for more photos. It may be possible to clean some of it from the Ground Electrode. |
Attachment 1: TiC#4_Dirty_GND_and_EE_electrodes.pdf
|
|
689
|
Wednesday, June 25, 2014, 12:49 |
Anders Mjos | South Hot-Cell | Standard Operation | TM3 | TiC#4 | Conductor insulator broken close to right TGHT terminal |
Anders Mjos wrote: |
When the Containment Box was opened today by Chad for a target change, we found the conductor insulator block B (ITD0054) to be broken close to the right TGHT terminal. Chad was nevertheless able to remove the target. See DocuShare and attached file for photos.
An attempt to replace the insulator will be made tomorrow with a spare.
A small sticky piece, likely off plastic material, was found next to the left main source tray insulator. The piece was removed from the Containment Box. See link above and attachment for photos.
|
The two insulators ITD0053 and ITD0054 was replaced this morning by Chad. Photos on DocuShare. All bolts torqued with torque wrench see attached PDF for values. |
Attachment 1: ITD0052C_revB.pdf
|
|