  545   Monday, November 18, 2013, 11:54 Bevan MossConditioning StationRepairTM2 Fault on TCS Chill

 This morning when I went to start HV conditioning CP2 and CP3 both had faults and the temperature of the water was ~27C. I reset the compressors by flipping the system reset switch. This cleared the fault and allowed the compressors to come one. To the best of my knowledge these faults happen as a result of compressor fluid pressure too low or high and temperature too low or high and lack of flow. The system cannot determine which one it was that caused the trip. The system restarted and faulted again. As I was watching this time it can be determined that the fault was the result of an over temperature event. This was the caused by the cooling fans not coming on. Which was traced to the fan VFD controllers which both read OP3 which is an Over voltage during constant speed operation. The operating manual lists these as the possible causes

The input voltage is fluctuating abnormally.

• Power network is greater than 200 kVA

• Power factor capacitor switching

• SCR switching on power network

• The drive controller is regenerating— the load causes the motor to run at a frequency higher than drive controller output frequency.

• Intermittent output phase fault

The proposed solutions are

• Install a line reactor.

• Check the input and output circuits for phase failure and rectify. 

I will continue to monitor over the next few days to see if this continues to happen. If it does I will contact ESC.

  546   Monday, November 18, 2013, 16:42 Bevan MossConditioning StationStandard OperationTM2 HV Testing

 The Glory of TM2 continues 100V at a time. Today I brought the module to 46kV and left it there for 1 hour. During this time there was only 1 spark. I then continues at up to 53kV. At this voltage the canbus continues to be temperamental when the module sparks. The module is still conditioning and I will continue more tomorrow. Attached is the dumped data and a screen shot of the conditioning from 46kV to 53kV.

Attachment 1: the_glory_of_TM2.JPG
the_glory_of_TM2.JPG
Attachment 2: 18112013_TM2_No_source_tray_HV_Test.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
11/18/2013 11:56:33.67635	                      0.000000350                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:34.66886	                      0.000000350                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:35.66751	                      0.000000350                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:36.67660	                      0.000000352                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:37.67534	                      0.000000352                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:38.68405	                      0.000000352                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:39.68261	                      0.000000352                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:40.68163	                      0.000000350                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:41.68032	                      0.000000350                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:42.67903	                      0.000000354                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:43.68805	                      0.000000350                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:44.68623	                      0.000000350                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:45.68500	                      0.000000350                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:46.69372	                      0.000000350                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:47.69322	                      0.000000352                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:48.69129	                      0.000000352                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:49.69014	                      0.000000352                      0.000003780                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:50.68910	                      0.000000350                      0.000003758                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:51.68802	                      0.000000352                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:52.68661	                      0.000000350                      0.000003780                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:53.68525	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:54.68443	                      0.000000354                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:55.68299	                      0.000000354                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:56.69356	                      0.000000350                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:57.69988	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:58.69998	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:56:59.70818	                      0.000000352                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:00.70672	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:01.71518	                      0.000000354                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:02.71393	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:03.72305	                      0.000000352                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:04.72168	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:05.71991	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:06.72879	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:07.72774	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:08.72786	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:09.73521	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:10.73360	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:11.73271	                      0.000000348                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:12.73140	                      0.000000352                      0.000003802                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:13.72987	                      0.000000352                      0.000003802                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:14.72862	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:15.73998	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:16.74679	                      0.000000352                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:17.74555	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:18.74357	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:19.74415	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:20.75099	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:21.76009	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:22.75889	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:23.75773	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:24.167647	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:25.167497	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:26.168548	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:27.168249	                      0.000000354                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:28.168091	                      0.000000354                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:29.168174	                      0.000000348                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:30.167873	                      0.000000357                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:31.168824	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:32.168589	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:33.168490	                      0.000000352                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:34.168368	                      0.000000348                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:35.169260	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:36.170079	                      0.000000350                      0.000003758                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:37.169962	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:38.169833	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:39.169741	                      0.000000348                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:40.169577	                      0.000000348                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:41.170683	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:42.171478	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:43.171240	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:44.171080	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:45.171080	                      0.000000352                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:46.171861	                      0.000000354                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:47.171901	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:48.173683	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:49.173532	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:50.173355	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:51.174221	                      0.000000350                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:52.174097	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:53.173980	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:54.173846	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:55.173701	                      0.000000352                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:56.174624	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:57.174550	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:58.175484	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:57:59.175364	                      0.000000352                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:00.176142	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:01.176991	                      0.000000348                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:02.176907	                      0.000000350                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:03.176736	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:04.176560	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:05.176444	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:06.176439	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:07.176466	                      0.000000352                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:08.176115	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:09.175970	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:10.175854	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:11.176710	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:12.176587	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:13.176518	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:14.177305	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:15.178256	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:16.178161	                      0.000000346                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:17.177934	                      0.000000346                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:18.177862	                      0.000000348                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:19.177767	                      0.000000350                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:20.178771	                      0.000000352                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:21.179458	                      0.000000348                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:22.180299	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:23.180173	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:24.180086	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:25.180011	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:26.180879	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:27.180711	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:28.180607	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:29.180448	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:30.180303	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:31.181202	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:32.181076	                      0.000000346                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:33.180951	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:34.180824	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:35.180722	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:36.180621	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:37.180619	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:38.181373	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:39.181195	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:40.181042	                      0.000000348                      0.000003736                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:41.181989	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:42.181796	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:43.181704	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:44.182677	                      0.000000350                      0.000003758                      0.000002087                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:45.182451	                      0.000000346                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:46.183316	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:48.803335	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:49.803216	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:50.802868	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:51.802603	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:52.803455	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:53.803339	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:54.803283	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:55.804102	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:56.803969	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:57.803933	                      0.000000348                      0.000003758                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:58.803707	                      0.000000348                      0.000003758                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:58:59.803667	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:00.803690	                      0.000000348                      0.000003758                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:01.803354	                      0.000000350                      0.000003758                      0.000002000                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:02.803204	                      0.000000350                      0.000003780                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:03.803102	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:04.802982	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:05.803883	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:06.803746	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:07.803569	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:08.803499	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:09.803404	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:10.803237	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:11.803090	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:12.802976	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:13.802824	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:14.802723	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:15.802654	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:16.802447	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:17.802315	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:18.802355	                      0.000000348                      0.000003736                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:19.802084	                      0.000000348                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:20.802934	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:21.802850	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:22.802712	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:23.802672	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:24.802472	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:25.802310	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:26.802213	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:28.87230	                      0.000000350                      0.000003736                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:29.86904	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:30.86799	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:31.87780	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:32.87546	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:33.87451	                      0.000000350                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:34.87271	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:35.87150	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:36.88072	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:37.87900	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:38.87899	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:39.87677	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:40.88567	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:41.89421	                      0.000000346                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:42.89294	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:43.89145	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:44.89053	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:45.88930	                      0.000000350                      0.000003780                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:46.89854	                      0.000000352                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:47.89750	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:48.89545	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:49.90415	                      0.000000350                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:50.90300	                      0.000000348                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:51.91305	                      0.000000350                      0.000003736                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:52.91017	                      0.000000350                      0.000003736                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:53.90976	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:54.91865	                      0.000000350                      0.000003758                      0.000002087                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:55.92687	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:56.93563	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:57.93420	                      0.000000346                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:58.93286	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 11:59:59.93135	                      0.000000348                      0.000003736                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:00.93026	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:01.93957	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:02.93759	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:03.93679	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:04.93605	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:05.93414	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:06.94302	                      0.000000348                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:07.94146	                      0.000000348                      0.000003736                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:08.94029	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:09.93914	                      0.000000350                      0.000003780                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:10.93783	                      0.000000348                      0.000003736                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:11.93656	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:12.93579	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:13.93443	                      0.000000352                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:14.93255	                      0.000000352                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:15.93164	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:16.94024	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:17.93919	                      0.000000348                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:18.93782	                      0.000000350                      0.000003758                      0.000002065                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:19.93656	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:20.93610	                      0.000000348                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:21.94365	                      0.000000348                      0.000003736                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:22.94271	                      0.000000350                      0.000003758                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:23.94121	                      0.000000350                      0.000003758                      0.000002043                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:24.94077	                      0.000000348                      0.000003802                      0.000002021                           BadVal                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:25.101301	                      0.000000348                      0.000003736                      0.000002000                            29.75                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:26.101770	                      0.000000352                      0.000003758                      0.000002043                            28.61                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:27.628314	                      0.000000348                      0.000003758                      0.000002043                            28.61                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:28.628508	                      0.000000352                      0.000003758                      0.000002021                            28.61                           BadVal                           BadVal                           BadVal
11/18/2013 12:00:29.629329	                      0.000000350                      0.000003758                      0.000002043                            28.61                             0.48                           BadVal                           BadVal
11/18/2013 12:00:30.629181	                      0.000000350                      0.000003758                      0.000002043                            29.75                             0.48                           BadVal                           BadVal
11/18/2013 12:00:31.630128	                      0.000000348                      0.000003736                      0.000002043                            29.75                             0.48                           BadVal                           BadVal
11/18/2013 12:00:32.629945	                      0.000000348                      0.000003758                      0.000002043                            28.61                             0.48                           BadVal                           BadVal
11/18/2013 12:00:33.629793	                      0.000000348                      0.000003736                      0.000002043                            28.61                             0.48                           BadVal                           BadVal
11/18/2013 12:00:34.658234	                      0.000000348                      0.000003758                      0.000002043                            28.61                             0.48                           BadVal                           BadVal
11/18/2013 12:00:35.657546	                      0.000000348                      0.000003758                      0.000002043                            28.61                             0.48                           BadVal                           BadVal
11/18/2013 12:00:36.657419	                      0.000000348                      0.000003758                      0.000002087                            27.46                             0.48                             6.10                           BadVal
11/18/2013 12:00:37.657311	                      0.000000348                      0.000003736                      0.000002043                            27.46                             0.48                             6.10                           BadVal
11/18/2013 12:00:38.657194	                      0.000000348                      0.000003736                      0.000002043                            29.75                             0.48                             6.10                           BadVal
11/18/2013 12:00:39.658139	                      0.000000348                      0.000003736                      0.000002043                            29.75                             0.48                             6.10                           BadVal
11/18/2013 12:00:42.44788	                      0.000000348                      0.000003758                      0.000002021                            28.61                             0.48                             6.10                           BadVal
11/18/2013 12:00:43.44671	                      0.000000348                      0.000003758                      0.000002021                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:44.44499	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             5.49                             0.01
11/18/2013 12:00:45.44528	                      0.000000350                      0.000003758                      0.000002065                            28.61                             0.48                             5.49                             0.01
11/18/2013 12:00:46.44300	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:47.44150	                      0.000000346                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:48.43366	                      0.000000346                      0.000003758                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:00:49.44059	                      0.000000348                      0.000003758                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:00:50.43894	                      0.000000350                      0.000003758                      0.000002043                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:51.43674	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:52.44636	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:53.44585	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:54.45302	                      0.000000352                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:55.44355	                      0.000000352                      0.000003758                      0.000002043                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:00:56.44002	                      0.000000352                      0.000003780                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:00:57.44147	                      0.000000352                      0.000003736                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:00:58.44820	                      0.000000348                      0.000003758                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:00:59.44598	                      0.000000348                      0.000003758                      0.000002021                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:00.44519	                      0.000000350                      0.000003758                      0.000002021                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:01.44421	                      0.000000348                      0.000003758                      0.000002000                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:02.44217	                      0.000000348                      0.000003758                      0.000002000                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:03.44128	                      0.000000348                      0.000003736                      0.000002043                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:04.43981	                      0.000000348                      0.000003736                      0.000002021                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:05.43875	                      0.000000348                      0.000003736                      0.000002043                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:06.43730	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:01:07.43676	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:01:08.43483	                      0.000000348                      0.000003758                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:01:10.527029	                      0.000000350                      0.000003758                      0.000002043                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:11.526244	                      0.000000348                      0.000003758                      0.000002043                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:12.526954	                      0.000000348                      0.000003736                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:13.526789	                      0.000000348                      0.000003736                      0.000002065                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:01:14.526783	                      0.000000348                      0.000003758                      0.000002043                            28.61                             0.48                             6.10                             0.01
11/18/2013 12:01:15.526585	                      0.000000350                      0.000003736                      0.000002065                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:17.268629	                      0.000000350                      0.000003758                      0.000002043                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:18.269323	                      0.000000348                      0.000003758                      0.000002065                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:19.269066	                      0.000000348                      0.000003758                      0.000002043                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:20.269024	                      0.000000348                      0.000003758                      0.000002043                            29.75                             0.48                             6.10                             0.01
11/18/2013 12:01:21.268809	                      0.000000348                      0.000003758                      0.000002065                            27.46                             0.48                             6.10                             0.01
11/18/2013 12:01:22.268839	                      0.000000350                      0.000003736                      0.000002043                             8.01                             0.36                             6.10                             0.01
11/18/2013 12:01:23.269588	                      0.000000350                      0.000003758                      0.000002065                             8.01                             0.36                             6.10                             0.01
11/18/2013 12:01:24.269513	                      0.000000348                      0.000003758                      0.000002043                             8.01                             0.73                             6.10                             0.01
11/18/2013 12:01:25.269349	                      0.000000346                      0.000003736                      0.000002021                             8.01                             0.73                             6.10                             0.01
11/18/2013 12:01:26.269482	                      0.000000346                      0.000003758                      0.000002043                             5.72                             0.61                             6.10                             0.01
11/18/2013 12:01:27.270296	                      0.000000350                      0.000003758                      0.000002043                             5.72                             0.61                             6.10                             0.01
11/18/2013 12:01:28.269961	                      0.000000350                      0.000003736                      0.000002043                            10.29                             0.85                             6.10                             0.01
11/18/2013 12:01:29.269871	                      0.000000348                      0.000003758                      0.000002043                            10.29                             0.85                             6.10                             0.01
11/18/2013 12:01:30.269726	                      0.000000350                      0.000003736                      0.000002043                             8.01                             0.85                             6.10                             0.01
11/18/2013 12:01:31.369724	                      0.000000348                      0.000003780                      0.000002043                             8.01                             0.85                             6.10                             0.01
11/18/2013 12:01:32.369423	                      0.000000348                      0.000003758                      0.000002065                            10.29                             0.73                             6.10                             0.01
11/18/2013 12:01:33.370375	                      0.000000350                      0.000003758                      0.000002065                            10.29                             0.73                             6.10                             0.01
11/18/2013 12:01:34.370213	                      0.000000348                      0.000003780                      0.000002043                            11.44                             0.73                             6.10                             0.01
11/18/2013 12:01:35.370088	                      0.000000350                      0.000003780                      0.000002043                            11.44                             0.73                             6.10                             0.01
11/18/2013 12:01:36.369921	                      0.000000350                      0.000003758                      0.000002043                             4.57                             0.85                             6.10                             0.01
11/18/2013 12:01:37.585188	                      0.000000348                      0.000003758                      0.000002043                             4.57                             0.85                             6.10                             0.01
... 15829 more lines ...
  547   Monday, November 18, 2013, 16:44 Bevan MossConditioning StationStandard Operation  Testing of cooling package

 I have tested all of the compressors for TCS. All are operational and cycled as they should. 

  550   Tuesday, November 19, 2013, 16:55 Bevan MossConditioning StationStandard OperationTM2 HV conditioning

 HV conditioning of TM2 continued today. At ~53.5kV the module started to spark externally to the HV cover. This is the first time the cover has been tested to this high of a voltage due to the limitations of the modules. As such for the conditioning station to achieve 60kV while keeping the target hall open of personnel the cover and cage will need to be modified. To continue with HV testing of TM2 the cover was removed and the target hall locked out as per the procedure covered in Document 70039 "ISAC Conditioning Station: First Lock-Out and High-Voltage "ON". With the cover off the module was able to achieve ~56.7kV without the Einzel lens on. Eliminate the Einzel lens as a potential source of sparking it was brought to 25kV while the module continued conditioning. Maximum voltage achieve under this configuration was 57.1kV. Increments are now 50V steps. The Canbus continues to be very sensitive to any sparking and is slowing the process down considerably. It does however appear that the module is continuing to condition. I will continue tomorrow after the module moves to attempt to reach 60kV and hold it for 1 hour.

Attachment 1: external_sparking.JPG
external_sparking.JPG
Attachment 2: 19112013_HV_conditioning_TM2.JPG
19112013_HV_conditioning_TM2.JPG
Attachment 3: 19112013_TM2_No_source_tray_HV_Test_no_cover.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
11/19/2013 14:05:53.354722	                      0.000000302                      0.000003362                      0.000001516                            11.44                             0.18                             4.88                             0.03
11/19/2013 14:05:54.354616	                      0.000000300                      0.000003362                      0.000001516                            18.31                             0.18                             4.88                             0.03
11/19/2013 14:05:55.354491	                      0.000000304                      0.000003340                      0.000001516                            18.31                             0.18                             4.88                             0.03
11/19/2013 14:05:56.355471	                      0.000000304                      0.000003340                      0.000001538                            18.31                             0.18                             4.88                             0.03
11/19/2013 14:05:57.355260	                      0.000000304                      0.000003362                      0.000001538                            21.74                             0.18                             4.88                             0.03
11/19/2013 14:05:58.356309	                      0.000000304                      0.000003362                      0.000001516                            21.74                             0.18                             4.88                             0.03
11/19/2013 14:05:59.355939	                      0.000000304                      0.000003362                      0.000001516                            25.17                             0.30                             4.88                             0.03
11/19/2013 14:06:00.356012	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.30                             4.88                             0.03
11/19/2013 14:06:01.356728	                      0.000000300                      0.000003362                      0.000001538                            26.32                             0.30                             4.88                             0.03
11/19/2013 14:06:02.356720	                      0.000000304                      0.000003362                      0.000001516                            26.32                             0.30                             4.88                             0.03
11/19/2013 14:06:03.356444	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:04.357380	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:05.357218	                      0.000000302                      0.000003362                      0.000001538                            26.32                             0.30                             5.49                             0.03
11/19/2013 14:06:06.358329	                      0.000000306                      0.000003362                      0.000001538                            26.32                             0.30                             5.49                             0.03
11/19/2013 14:06:07.359140	                      0.000000302                      0.000003384                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:08.358814	                      0.000000302                      0.000003340                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:09.358730	                      0.000000306                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:10.358605	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:11.359545	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:12.359312	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:13.359243	                      0.000000304                      0.000003384                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:14.359103	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:15.359040	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:16.359868	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:17.359724	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:18.359599	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:19.359585	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:20.359298	                      0.000000304                      0.000003384                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:21.360304	                      0.000000304                      0.000003384                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:22.360120	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:23.359987	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:24.359901	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:25.359840	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:26.360642	                      0.000000300                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:27.360471	                      0.000000300                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:28.359710	                      0.000000306                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:29.360203	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:30.360083	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:31.360917	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:32.360825	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:33.360728	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:34.360551	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:35.360556	                      0.000000304                      0.000003340                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:36.361435	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:37.361170	                      0.000000302                      0.000003384                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:38.361078	                      0.000000306                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:39.360960	                      0.000000304                      0.000003362                      0.000001560                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:40.360827	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:41.361763	                      0.000000302                      0.000003362                      0.000001560                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:42.362590	                      0.000000302                      0.000003362                      0.000001560                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:43.362450	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:44.362283	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:45.363190	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:46.364029	                      0.000000302                      0.000003362                      0.000001494                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:47.363963	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:48.363929	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:49.364676	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:50.364535	                      0.000000304                      0.000003340                      0.000001560                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:51.365463	                      0.000000300                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:06:52.366307	                      0.000000300                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:53.366193	                      0.000000308                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:54.366069	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:55.365938	                      0.000000306                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:56.366809	                      0.000000304                      0.000003362                      0.000001516                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:06:57.366654	                      0.000000304                      0.000003362                      0.000001538                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:06:58.367523	                      0.000000304                      0.000003384                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:06:59.367430	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:00.367278	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:01.367220	                      0.000000306                      0.000003340                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:02.367054	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:03.366900	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:04.366837	                      0.000000304                      0.000003340                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:05.366830	                      0.000000304                      0.000003362                      0.000001560                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:06.367680	                      0.000000300                      0.000003340                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:07.367422	                      0.000000302                      0.000003362                      0.000001494                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:08.367307	                      0.000000308                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:09.367180	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:10.367078	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:11.368047	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:12.367770	                      0.000000302                      0.000003362                      0.000001560                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:13.367637	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:14.367544	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:15.367429	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:16.368326	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:17.368176	                      0.000000306                      0.000003362                      0.000001516                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:18.368039	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.30                             5.49                             0.03
11/19/2013 14:07:19.367933	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:20.367835	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:21.368721	                      0.000000300                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:22.368549	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:23.368413	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:24.368292	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:25.368197	                      0.000000304                      0.000003362                      0.000001538                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:26.369153	                      0.000000304                      0.000003362                      0.000001538                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:27.369877	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:28.369786	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:29.369767	                      0.000000306                      0.000003340                      0.000001538                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:30.369531	                      0.000000302                      0.000003362                      0.000001516                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:31.370442	                      0.000000304                      0.000003362                      0.000001560                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:32.370291	                      0.000000302                      0.000003362                      0.000001538                            29.75                             0.30                             5.49                             0.03
11/19/2013 14:07:33.370168	                      0.000000304                      0.000003362                      0.000001560                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:34.369996	                      0.000000304                      0.000003362                      0.000001560                            28.61                             0.30                             5.49                             0.03
11/19/2013 14:07:35.369937	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:36.370838	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:37.370668	                      0.000000302                      0.000003362                      0.000001560                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:38.370749	                      0.000000304                      0.000003362                      0.000001582                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:39.371415	                      0.000000302                      0.000003384                      0.000001560                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:40.371286	                      0.000000304                      0.000003384                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:41.372115	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:42.371999	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:43.371914	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:44.371842	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:45.371657	                      0.000000302                      0.000003362                      0.000001560                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:46.372526	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:47.372407	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:48.372325	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:49.372151	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:50.373021	                      0.000000302                      0.000003362                      0.000001560                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:51.373956	                      0.000000304                      0.000003362                      0.000001560                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:07:52.373746	                      0.000000304                      0.000003384                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:07:53.373706	                      0.000000304                      0.000003362                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:54.373541	                      0.000000302                      0.000003362                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:55.373384	                      0.000000308                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:56.373439	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:07:57.373107	                      0.000000304                      0.000003362                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:58.373036	                      0.000000306                      0.000003384                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:07:59.372863	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:00.372736	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:01.373696	                      0.000000306                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:02.373648	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:03.374534	                      0.000000300                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:04.375263	                      0.000000308                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:05.376101	                      0.000000308                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:06.377066	                      0.000000297                      0.000003362                      0.000001494                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:07.376910	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:08.376768	                      0.000000304                      0.000003318                      0.000001560                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:09.376642	                      0.000000306                      0.000003362                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:10.376520	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:11.376582	                      0.000000300                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:12.376266	                      0.000000300                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:13.376238	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:14.375983	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:15.375886	                      0.000000304                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:16.375820	                      0.000000306                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:17.375626	                      0.000000304                      0.000003340                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:18.375507	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:19.375369	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:20.376380	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:21.377197	                      0.000000304                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:22.377109	                      0.000000304                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:23.376905	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:24.376781	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:25.377666	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:26.377670	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:27.377464	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:28.378245	                      0.000000300                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:29.378131	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:30.378152	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:31.377926	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:32.377773	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:33.377608	                      0.000000304                      0.000003340                      0.000001560                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:34.378551	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:35.378336	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:36.379229	                      0.000000304                      0.000003340                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:37.379143	                      0.000000306                      0.000003340                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:38.380035	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:39.379852	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:40.379853	                      0.000000304                      0.000003340                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:41.380667	                      0.000000300                      0.000003362                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:42.380496	                      0.000000302                      0.000003340                      0.000001582                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:43.381497	                      0.000000306                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:44.382284	                      0.000000306                      0.000003340                      0.000001494                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:45.382081	                      0.000000306                      0.000003362                      0.000001494                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:08:46.382969	                      0.000000306                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:47.382888	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:48.382765	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:49.382582	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:50.382483	                      0.000000306                      0.000003362                      0.000001494                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:51.383390	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:52.383236	                      0.000000306                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:53.383142	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:54.382977	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:55.383033	                      0.000000302                      0.000003362                      0.000001560                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:56.383746	                      0.000000302                      0.000003384                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:57.383610	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:08:58.384517	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:08:59.384360	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:00.384233	                      0.000000306                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:01.384098	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:02.384008	                      0.000000302                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:03.383841	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:04.384838	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:05.384849	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:06.385552	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:07.385371	                      0.000000306                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:08.385188	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:09.385098	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:10.384964	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:11.385810	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:12.385870	                      0.000000306                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:13.386593	                      0.000000304                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:14.386563	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:15.386310	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:16.387331	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:17.387108	                      0.000000300                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:18.386975	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:19.386848	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:20.386684	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:21.387583	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:22.387469	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:23.387339	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:24.387222	                      0.000000304                      0.000003362                      0.000001560                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:25.387167	                      0.000000306                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:26.388077	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:27.387859	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:28.387670	                      0.000000304                      0.000003384                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:29.387547	                      0.000000304                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:30.387462	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:31.388291	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:32.388300	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:33.388040	                      0.000000302                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:34.387967	                      0.000000308                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:35.387846	                      0.000000304                      0.000003318                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:36.388795	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:37.389717	                      0.000000302                      0.000003384                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:38.389408	                      0.000000302                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:39.389291	                      0.000000302                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:40.389397	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:41.390033	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:42.389915	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:43.389825	                      0.000000306                      0.000003384                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:09:44.389697	                      0.000000304                      0.000003384                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:09:45.389571	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:46.390485	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:47.391343	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:48.391159	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:49.391072	                      0.000000302                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:50.390947	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:51.391775	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:52.391202	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:53.391826	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:54.392406	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:55.392281	                      0.000000304                      0.000003384                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:09:56.393178	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:57.393028	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:58.392904	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:09:59.392947	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:00.392649	                      0.000000302                      0.000003384                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:01.393587	                      0.000000302                      0.000003340                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:02.393437	                      0.000000300                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:03.393427	                      0.000000304                      0.000003384                      0.000001494                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:04.393216	                      0.000000302                      0.000003362                      0.000001494                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:05.393073	                      0.000000302                      0.000003362                      0.000001538                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:06.392979	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:07.392808	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:08.392747	                      0.000000302                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:09.393600	                      0.000000302                      0.000003340                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:10.393431	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:11.394321	                      0.000000304                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:12.394255	                      0.000000302                      0.000003362                      0.000001582                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:13.394061	                      0.000000306                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:14.393935	                      0.000000304                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:15.394815	                      0.000000304                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:16.395754	                      0.000000304                      0.000003362                      0.000001494                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:17.395575	                      0.000000302                      0.000003318                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:18.395428	                      0.000000304                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:19.395326	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:20.396197	                      0.000000306                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:21.397060	                      0.000000304                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:22.397959	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:23.397760	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:24.397660	                      0.000000304                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:25.397555	                      0.000000306                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:26.397473	                      0.000000304                      0.000003362                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:27.397292	                      0.000000304                      0.000003362                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:28.397275	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:29.397064	                      0.000000302                      0.000003362                      0.000001516                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:30.397950	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:31.398916	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:32.398700	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:33.398565	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:34.398475	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:35.399271	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:36.400292	                      0.000000300                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:37.400283	                      0.000000300                      0.000003384                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:38.399877	                      0.000000300                      0.000003362                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:39.400813	                      0.000000302                      0.000003362                      0.000001516                            29.75                             0.42                             5.49                             0.03
11/19/2013 14:10:40.401650	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:41.402517	                      0.000000302                      0.000003362                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:42.403427	                      0.000000302                      0.000003384                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:43.403303	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:44.403147	                      0.000000302                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:45.403017	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:46.403927	                      0.000000304                      0.000003362                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:47.403779	                      0.000000306                      0.000003340                      0.000001538                            27.46                             0.42                             5.49                             0.03
11/19/2013 14:10:48.404762	                      0.000000304                      0.000003340                      0.000001516                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:49.405527	                      0.000000302                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:50.405406	                      0.000000300                      0.000003362                      0.000001538                            28.61                             0.42                             5.49                             0.03
11/19/2013 14:10:51.405266	                      0.000000304                      0.000003340                      0.000001538                            28.61                             0.42                             5.49                             0.03
... 9169 more lines ...
Attachment 4: 19112013_TM2_No_source_tray_HV_Test.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
11/19/2013 10:41:01.318511	                      0.000000302                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:02.317614	                      0.000000304                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:03.317465	                      0.000000304                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:04.317355	                      0.000000304                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:05.402487	                      0.000000304                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:06.403328	                      0.000000302                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:07.403004	                      0.000000302                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:08.402906	                      0.000000302                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:09.402698	                      0.000000302                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:10.402606	                      0.000000304                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:11.403668	                      0.000000304                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:12.404343	                      0.000000302                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:13.404485	                      0.000000306                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:14.404091	                      0.000000300                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:15.404261	                      0.000000302                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:16.404970	                      0.000000300                      0.000003384                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:17.405939	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:18.405596	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:19.405470	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:20.405591	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:21.405361	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:22.405110	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:23.404945	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:24.405004	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:25.404869	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:26.405664	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:27.405452	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:28.405690	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:29.406257	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:30.406107	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:31.407176	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:32.406962	                      0.000000302                      0.000003362                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:33.407750	                      0.000000302                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:34.407588	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:35.407461	                      0.000000306                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:36.407365	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:37.407206	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:38.407144	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:39.406973	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:40.406863	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:41.407851	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:42.408741	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:43.408455	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:44.408363	                      0.000000300                      0.000003340                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:45.408507	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:46.409102	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:47.408996	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:48.409016	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:49.408903	                      0.000000304                      0.000003384                      0.000001516                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:50.408651	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:51.409561	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:52.409366	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:53.671050	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:54.675348	                      0.000000306                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:55.675949	                      0.000000300                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:56.676845	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:57.676692	                      0.000000300                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:58.676230	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:41:59.677764	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:00.677259	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:01.678167	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:02.679007	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:03.678882	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:04.679802	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:05.679736	                      0.000000300                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:06.680510	                      0.000000300                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:07.680434	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:08.680253	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:09.680303	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:10.680002	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:11.706336	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:12.706772	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:13.706749	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:14.707652	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:15.708502	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:16.709291	                      0.000000306                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:17.709139	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:18.709013	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:19.708875	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:20.708773	                      0.000000300                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:21.708676	                      0.000000300                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:22.708491	                      0.000000300                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:23.708396	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:24.708237	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:25.708129	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:26.709068	                      0.000000306                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:27.709892	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:28.709771	                      0.000000302                      0.000003362                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:29.709605	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:30.709518	                      0.000000300                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:31.710437	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:32.710268	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:33.710139	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:34.710975	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:35.710972	                      0.000000308                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:36.711931	                      0.000000302                      0.000003340                      0.000001604                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:37.769372	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:38.769499	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:39.769426	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:40.768586	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:41.769111	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:42.769018	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:43.768903	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:44.768752	                      0.000000300                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:45.768651	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:46.769518	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:47.769367	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:48.769247	                      0.000000306                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:49.769168	                      0.000000306                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:50.769023	                      0.000000302                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:51.769882	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:52.769737	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:53.851442	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:54.851454	                      0.000000304                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:55.851327	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:56.852247	                      0.000000304                      0.000003340                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:57.852146	                      0.000000302                      0.000003340                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:58.851996	                      0.000000300                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:42:59.851955	                      0.000000300                      0.000003362                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:00.851730	                      0.000000304                      0.000003362                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:01.851594	                      0.000000304                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:02.851462	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:03.851516	                      0.000000300                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:04.851223	                      0.000000302                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:05.851091	                      0.000000300                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:06.850946	                      0.000000300                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:07.850844	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:08.851722	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:10.796013	                      0.000000304                      0.000003384                      0.000001538                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:11.796351	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:12.796332	                      0.000000302                      0.000003362                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:13.796099	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:14.795971	                      0.000000302                      0.000003384                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:15.795875	                      0.000000304                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:16.795690	                      0.000000304                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:17.795627	                      0.000000302                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:18.796444	                      0.000000302                      0.000003362                      0.000001560                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:19.796344	                      0.000000300                      0.000003384                      0.000001582                           BadVal                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:20.796217	                      0.000000300                      0.000003384                      0.000001560                            26.32                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:21.797113	                      0.000000302                      0.000003362                      0.000001560                            26.32                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:22.796966	                      0.000000304                      0.000003362                      0.000001560                            26.32                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:23.796853	                      0.000000302                      0.000003384                      0.000001560                            26.32                           BadVal                           BadVal                           BadVal
11/19/2013 10:43:24.797719	                      0.000000304                      0.000003384                      0.000001560                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:25.797602	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:26.797843	                      0.000000302                      0.000003384                      0.000001538                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:27.797315	                      0.000000302                      0.000003384                      0.000001582                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:28.797410	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:29.797095	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.48                           BadVal                           BadVal
11/19/2013 10:43:31.261550	                      0.000000304                      0.000003384                      0.000001560                            26.32                             0.48                           BadVal                           BadVal
11/19/2013 10:43:32.261753	                      0.000000304                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                           BadVal
11/19/2013 10:43:33.261681	                      0.000000304                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                           BadVal
11/19/2013 10:43:34.261527	                      0.000000302                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                           BadVal
11/19/2013 10:43:35.261401	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                           BadVal
11/19/2013 10:43:36.261291	                      0.000000304                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:37.261143	                      0.000000304                      0.000003384                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:38.357263	                      0.000000306                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:39.357863	                      0.000000306                      0.000003384                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:40.357775	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:41.358683	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:42.358279	                      0.000000304                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:43.358382	                      0.000000304                      0.000003384                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:44.358287	                      0.000000302                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:45.358241	                      0.000000302                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:46.359014	                      0.000000304                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:47.358900	                      0.000000302                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:48.553700	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:49.617444	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:50.617485	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:51.617351	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:52.617213	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:53.618083	                      0.000000302                      0.000003362                      0.000001604                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:54.693871	                      0.000000302                      0.000003362                      0.000001604                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:55.693812	                      0.000000302                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:43:56.693704	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:57.693643	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:58.693461	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:43:59.693350	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:00.693181	                      0.000000302                      0.000003384                      0.000001604                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:01.694099	                      0.000000300                      0.000003362                      0.000001604                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:02.694989	                      0.000000302                      0.000003362                      0.000001604                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:03.694798	                      0.000000302                      0.000003384                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:04.695712	                      0.000000304                      0.000003384                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:05.695611	                      0.000000306                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:06.696507	                      0.000000304                      0.000003384                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:07.697388	                      0.000000306                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:08.697233	                      0.000000300                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:09.697084	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:10.697082	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:11.697791	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:12.698710	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:13.698611	                      0.000000306                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:14.698625	                      0.000000302                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:15.698313	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:16.699228	                      0.000000304                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:17.699088	                      0.000000302                      0.000003384                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:18.700241	                      0.000000302                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:19.699985	                      0.000000304                      0.000003362                      0.000001516                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:20.699919	                      0.000000302                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:21.700749	                      0.000000304                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:22.700485	                      0.000000302                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:23.700313	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:24.700161	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:25.700124	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:26.826729	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:27.826774	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:28.826673	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:29.826713	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:30.826398	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:31.826314	                      0.000000304                      0.000003362                      0.000001538                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:32.826263	                      0.000000304                      0.000003362                      0.000001538                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:33.826027	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:34.825896	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:35.825862	                      0.000000304                      0.000003384                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:36.825771	                      0.000000300                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:37.826602	                      0.000000302                      0.000003384                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:38.826434	                      0.000000300                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:39.826342	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:40.826153	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:41.826047	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:42.825889	                      0.000000304                      0.000003384                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:43.825806	                      0.000000300                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:44.825678	                      0.000000302                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:45.825560	                      0.000000300                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:46.825450	                      0.000000304                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:47.825323	                      0.000000302                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:48.825136	                      0.000000302                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:49.825003	                      0.000000302                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:50.825965	                      0.000000304                      0.000003384                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:51.825800	                      0.000000302                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:52.825783	                      0.000000300                      0.000003340                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:53.826612	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:54.826401	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:44:57.57542	                      0.000000304                      0.000003362                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:58.57013	                      0.000000306                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:44:59.56879	                      0.000000302                      0.000003362                      0.000001538                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:00.146237	                      0.000000300                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:01.146631	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:02.146917	                      0.000000304                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:03.146342	                      0.000000304                      0.000003384                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:45:04.146247	                      0.000000304                      0.000003362                      0.000001560                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:45:05.146129	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:06.146037	                      0.000000300                      0.000003362                      0.000001560                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:07.146918	                      0.000000302                      0.000003362                      0.000001538                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:45:08.146753	                      0.000000304                      0.000003384                      0.000001582                            26.32                             0.48                             6.10                             0.01
11/19/2013 10:45:09.146640	                      0.000000302                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:10.146497	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:11.146466	                      0.000000304                      0.000003362                      0.000001582                            25.17                             0.48                             6.10                             0.01
11/19/2013 10:45:12.147338	                      0.000000300                      0.000003362                      0.000001582                             4.57                             0.85                             6.10                             0.01
11/19/2013 10:45:13.147084	                      0.000000300                      0.000003384                      0.000001560                             4.57                             0.85                             6.10                             0.01
11/19/2013 10:45:14.147016	                      0.000000302                      0.000003362                      0.000001582                            12.58                             0.85                             6.10                             0.01
11/19/2013 10:45:15.146891	                      0.000000304                      0.000003362                      0.000001538                            12.58                             0.61                             6.10                             0.01
11/19/2013 10:45:16.146881	                      0.000000304                      0.000003362                      0.000001560                            16.02                             0.42                             6.10                             0.01
11/19/2013 10:45:17.147759	                      0.000000302                      0.000003362                      0.000001560                            16.02                             0.42                             6.10                             0.01
11/19/2013 10:45:18.147575	                      0.000000302                      0.000003384                      0.000001560                             3.43                             0.42                             6.10                             0.01
11/19/2013 10:45:19.147328	                      0.000000302                      0.000003362                      0.000001560                             3.43                             0.42                             6.10                             0.01
11/19/2013 10:45:20.147232	                      0.000000300                      0.000003384                      0.000001582                            11.44                             0.42                             6.10                             0.01
11/19/2013 10:45:21.148144	                      0.000000302                      0.000003384                      0.000001560                            14.87                             0.48                             6.10                             0.01
11/19/2013 10:45:22.149018	                      0.000000304                      0.000003362                      0.000001560                            18.31                             0.48                             6.10                             0.01
11/19/2013 10:45:23.150194	                      0.000000306                      0.000003384                      0.000001560                            18.31                             0.48                             6.10                             0.01
11/19/2013 10:45:24.150804	                      0.000000302                      0.000003362                      0.000001582                            21.74                             0.48                             6.10                             0.01
11/19/2013 10:45:25.150602	                      0.000000300                      0.000003362                      0.000001582                            21.74                             0.48                             6.10                             0.01
11/19/2013 10:45:26.150449	                      0.000000300                      0.000003384                      0.000001538                            21.74                             0.48                             6.10                             0.01
11/19/2013 10:45:27.151409	                      0.000000304                      0.000003384                      0.000001560                            21.74                             0.48                             6.10                             0.01
11/19/2013 10:45:28.151267	                      0.000000304                      0.000003362                      0.000001560                            22.88                             0.48                             6.10                             0.01
11/19/2013 10:45:29.151108	                      0.000000302                      0.000003362                      0.000001582                            22.88                             0.48                             6.10                             0.01
11/19/2013 10:45:30.151084	                      0.000000300                      0.000003362                      0.000001560                            24.03                             0.24                             6.10                             0.01
11/19/2013 10:45:31.150818	                      0.000000300                      0.000003362                      0.000001538                            11.44                             0.24                             6.10                             0.01
11/19/2013 10:45:32.151726	                      0.000000302                      0.000003362                      0.000001538                           510.41                             2.92                             7.32                             0.01
11/19/2013 10:45:33.151733	                      0.000000302                      0.000003362                      0.000001538                           511.55                             0.12                             7.32                             0.01
11/19/2013 10:45:34.151441	                      0.000000302                      0.000003362                      0.000001560                          1511.78                             3.84                             7.93                             0.01
11/19/2013 10:45:35.151315	                      0.000000302                      0.000003362                      0.000001582                          2011.90                             2.86                             9.15                             0.01
11/19/2013 10:45:36.151190	                      0.000000302                      0.000003362                      0.000001560                          3512.24                            12.14                             9.76                             0.01
11/19/2013 10:45:37.151117	                      0.000000302                      0.000003362                      0.000001538                          5517.28                            11.16                             9.76                             0.01
11/19/2013 10:45:38.150938	                      0.000000302                      0.000003362                      0.000001560                          7514.30                            17.15                            15.25                             0.01
11/19/2013 10:45:39.150851	                      0.000000306                      0.000003384                      0.000001582                          9015.79                            12.32                            15.25                             0.01
11/19/2013 10:45:40.150756	                      0.000000302                      0.000003384                      0.000001582                         11016.25                            15.25                            15.25                             0.01
11/19/2013 10:45:41.150571	                      0.000000302                      0.000003384                      0.000001560                         13016.70                            17.94                            15.25                             0.01
11/19/2013 10:45:42.151464	                      0.000000304                      0.000003362                      0.000001560                         14518.19                            19.22                            16.47                             0.01
11/19/2013 10:45:43.151354	                      0.000000302                      0.000003362                      0.000001582                         16522.08                            22.33                            16.47                             0.01
11/19/2013 10:45:44.151303	                      0.000000302                      0.000003384                      0.000001582                         18519.11                            23.49                            17.09                             0.01
11/19/2013 10:45:45.151188	                      0.000000302                      0.000003362                      0.000001582                         20585.94                            28.56                            17.09                             0.01
11/19/2013 10:45:46.151036	                      0.000000302                      0.000003362                      0.000001582                         22523.46                            30.76                            17.70                             0.01
11/19/2013 10:45:47.152035	                      0.000000302                      0.000003362                      0.000001582                         24521.62                            28.44                            17.70                             0.01
11/19/2013 10:45:48.151742	                      0.000000302                      0.000003384                      0.000001582                         26520.94                            31.37                            17.09                             0.01
11/19/2013 10:45:49.151657	                      0.000000304                      0.000003362                      0.000001560                         28524.83                            31.73                            17.70                             0.01
11/19/2013 10:45:50.151484	                      0.000000306                      0.000003362                      0.000001582                         30025.17                            35.09                            17.70                             0.01
11/19/2013 10:45:51.151476	                      0.000000304                      0.000003362                      0.000001582                         32027.92                            40.10                            17.70                             0.01
11/19/2013 10:45:52.151329	                      0.000000302                      0.000003384                      0.000001560                         34024.94                            42.54                            17.70                             0.01
11/19/2013 10:45:53.151052	                      0.000000302                      0.000003362                      0.000001538                         36027.69                            38.87                            17.70                             0.01
11/19/2013 10:45:54.150967	                      0.000000304                      0.000003362                      0.000001560                         37528.03                            43.15                            17.70                             0.01
11/19/2013 10:45:55.150804	                      0.000000304                      0.000003362                      0.000001560                         39026.09                            43.09                            17.09                             0.01
11/19/2013 10:45:56.150672	                      0.000000304                      0.000003384                      0.000001560                         40528.72                            43.88                            17.09                             0.01
11/19/2013 10:45:57.151583	                      0.000000306                      0.000003384                      0.000001538                         42027.92                            45.96                            15.25                             0.01
11/19/2013 10:45:58.151490	                      0.000000302                      0.000003362                      0.000001560                         43094.52                            46.50                            15.25                             0.01
11/19/2013 10:45:59.151326	                      0.000000300                      0.000003362                      0.000001538                         44528.49                            48.64                            31.12                             0.01
11/19/2013 10:46:00.151211	                      0.000000302                      0.000003362                      0.000001560                         45529.86                            49.74                            50.65                             0.01
11/19/2013 10:46:01.151080	                      0.000000304                      0.000003384                      0.000001538                         47031.35                            51.33                            68.36                             0.01
11/19/2013 10:46:02.151382	                      0.000000304                      0.000003384                      0.000001538                         48028.15                            54.07                            78.73                             0.01
11/19/2013 10:46:03.151823	                      0.000000304                      0.000003384                      0.000001582                         49029.52                            54.44                            76.90                             0.01
... 2782 more lines ...
  553   Wednesday, November 20, 2013, 13:52 Bevan MossConditioning StationStandard OperationTM2 HV testing of TM2

 HV testing without the cover continued today. With the EINZEL lens at 30kV the target module was able to achieve 58.7kV. At this voltage any spark was reeking havoc on the electronics of the TCS. Vacuum gauges signals were occasionally lost, the thermocouple reading would occasionally be lost, turbo pump would turn off. All of these events caused the interlocks to trip resulting in the power supplies to be turned off. As a result I bypassed majority of the interlocks to prevent this from happening. Ultimately as spark took out the CANBUS controller first for the EINZEL lens and then for the BIAS. David Morris has been contacted to have them replaced. The damage of the CANBUS controller for these power supplies is becoming a common problem and should be investigated for if there is a better solution. During testing I experimented with raising the BIAS to near its limit followed by the EINZEL lens and vise versa. From this it was determined that the EINZEL must be raised to high voltage before the BIAS otherwise sparking occurs. Even a step from 0 to 500 volts on the ENIZEL lens with the BIAS at 55kV caused sparking. There are a few combinations of testing along this line I would like to continue with but initially my though is that the BIAS and ENIZEL do not have sufficient clearance for the BIAS to operate above 55kV. Attached is a screen shot of the strip tool and the data. I have not heard from David yet but I do not expect the TCS to be operational today. 

Attachment 1: 20112013_HV_conditioning_TM2.JPG
20112013_HV_conditioning_TM2.JPG
Attachment 2: 20112013_TM2_No_source_tray_HV_Test_no_cover.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
11/20/2013 10:34:48.414676	                      0.000000253                      0.000003120                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:49.413724	                      0.000000253                      0.000003098                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:50.414780	                      0.000000256                      0.000003120                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:51.414583	                      0.000000258                      0.000003120                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:52.414423	                      0.000000260                      0.000003120                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:53.415237	                      0.000000258                      0.000003120                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:54.416059	                      0.000000258                      0.000003098                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:55.506062	                      0.000000258                      0.000003098                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:56.506814	                      0.000000258                      0.000003120                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:57.506697	                      0.000000256                      0.000003098                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:58.506780	                      0.000000258                      0.000003120                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:34:59.506511	                      0.000000260                      0.000003120                      0.000001252                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:00.507321	                      0.000000258                      0.000003120                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:01.507271	                      0.000000258                      0.000003120                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:02.507196	                      0.000000256                      0.000003098                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:03.507937	                      0.000000256                      0.000003098                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:04.508830	                      0.000000256                      0.000003098                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:05.509815	                      0.000000253                      0.000003120                      0.000001230                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:06.510560	                      0.000000258                      0.000003120                      0.000001208                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:07.511442	                      0.000000260                      0.000003120                      0.000001208                           BadVal                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:08.511382	                      0.000000258                      0.000003098                      0.000001208                            27.46                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:09.511380	                      0.000000260                      0.000003120                      0.000001252                            26.32                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:10.511063	                      0.000000258                      0.000003120                      0.000001252                            26.32                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:11.510938	                      0.000000256                      0.000003098                      0.000001252                            27.46                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:12.510832	                      0.000000256                      0.000003120                      0.000001208                            27.46                           BadVal                           BadVal                           BadVal
11/20/2013 10:35:13.510688	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                           BadVal                           BadVal
11/20/2013 10:35:14.510527	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                           BadVal                           BadVal
11/20/2013 10:35:15.510410	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                           BadVal                           BadVal
11/20/2013 10:35:16.510321	                      0.000000256                      0.000003098                      0.000001230                            27.46                             0.42                           BadVal                           BadVal
11/20/2013 10:35:17.510214	                      0.000000256                      0.000003098                      0.000001230                            26.32                             0.42                           BadVal                           BadVal
11/20/2013 10:35:18.510025	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                           BadVal
11/20/2013 10:35:19.509934	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                           BadVal
11/20/2013 10:35:20.509860	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                           BadVal
11/20/2013 10:35:21.511728	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                           BadVal
11/20/2013 10:35:22.511632	                      0.000000260                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                           BadVal
11/20/2013 10:35:23.511584	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:24.591659	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:25.729112	                      0.000000253                      0.000003098                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:26.729088	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:27.729906	                      0.000000253                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:28.729930	                      0.000000260                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:29.729660	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:30.729489	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:31.729372	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:32.730305	                      0.000000253                      0.000003098                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:33.853965	                      0.000000256                      0.000003120                      0.000001252                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:34.854006	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:35.949159	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:36.949749	                      0.000000256                      0.000003098                      0.000001252                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:37.949644	                      0.000000256                      0.000003120                      0.000001252                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:38.949535	                      0.000000256                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:39.950466	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:41.28198	                      0.000000256                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:42.34724	                      0.000000256                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:43.34971	                      0.000000256                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:44.34865	                      0.000000260                      0.000003098                      0.000001252                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:45.34739	                      0.000000258                      0.000003120                      0.000001252                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:46.34576	                      0.000000258                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:47.34484	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:48.35380	                      0.000000258                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:49.35302	                      0.000000256                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:50.36136	                      0.000000253                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:35:51.35938	                      0.000000253                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:52.35873	                      0.000000260                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:53.35802	                      0.000000260                      0.000003098                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:54.35700	                      0.000000260                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:55.35442	                      0.000000260                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:56.35354	                      0.000000256                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:57.35238	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:58.36111	                      0.000000253                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:35:59.35984	                      0.000000260                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:00.35832	                      0.000000260                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:01.35689	                      0.000000260                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:02.144399	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:03.144478	                      0.000000258                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:04.144502	                      0.000000256                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:05.145332	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:06.145089	                      0.000000253                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:07.145209	                      0.000000260                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:08.145838	                      0.000000260                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:09.146802	                      0.000000260                      0.000003098                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:10.146584	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:11.146460	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:12.146294	                      0.000000256                      0.000003098                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:13.146305	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:14.146042	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:15.145915	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:16.145794	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:17.145705	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:18.145906	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:19.145434	                      0.000000258                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:20.145323	                      0.000000253                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:21.145202	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:22.145076	                      0.000000260                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:23.146118	                      0.000000260                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:24.145825	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:25.155723	                      0.000000258                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:26.155570	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:27.155437	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:28.155279	                      0.000000256                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:29.155155	                      0.000000256                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:30.155132	                      0.000000256                      0.000003098                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:31.155083	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:32.154768	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:33.154675	                      0.000000258                      0.000003098                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:34.154594	                      0.000000253                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:35.155716	                      0.000000256                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:36.156306	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:37.156322	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:38.156054	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:39.155899	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:40.313843	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:41.313756	                      0.000000253                      0.000003120                      0.000001208                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:42.313502	                      0.000000253                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:43.313407	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:44.313288	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:45.313123	                      0.000000258                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:46.313028	                      0.000000256                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:47.312863	                      0.000000256                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:48.313869	                      0.000000258                      0.000003120                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:49.314706	                      0.000000256                      0.000003098                      0.000001230                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:50.315547	                      0.000000253                      0.000003120                      0.000001186                            26.32                             0.42                             5.49                             0.01
11/20/2013 10:36:51.315404	                      0.000000260                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:52.315285	                      0.000000256                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:53.316161	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:54.316185	                      0.000000260                      0.000003098                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:55.317074	                      0.000000256                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:56.316803	                      0.000000258                      0.000003120                      0.000001208                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:57.316655	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:58.316082	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:36:59.316373	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:37:00.316469	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             5.49                             0.01
11/20/2013 10:37:01.316114	                      0.000000256                      0.000003120                      0.000001230                            27.46                             0.42                             0.61                             0.01
11/20/2013 10:37:02.316025	                      0.000000260                      0.000003098                      0.000001230                            26.32                             0.42                             0.61                             0.01
11/20/2013 10:37:03.316970	                      0.000000260                      0.000003120                      0.000001230                             8.01                             0.42                             0.61                             0.01
11/20/2013 10:37:04.316771	                      0.000000256                      0.000003120                      0.000001230                             8.01                             0.42                             0.61                             0.01
11/20/2013 10:37:05.316651	                      0.000000253                      0.000003098                      0.000001230                             9.15                             0.79                             4.27                             0.01
11/20/2013 10:37:06.316545	                      0.000000256                      0.000003098                      0.000001230                             9.15                             0.79                             4.27                             0.01
11/20/2013 10:37:07.316358	                      0.000000256                      0.000003120                      0.000001230                            12.58                             0.79                             6.10                             0.01
11/20/2013 10:37:08.317387	                      0.000000256                      0.000003120                      0.000001208                            12.58                             0.79                             5.49                             0.01
11/20/2013 10:37:09.318100	                      0.000000256                      0.000003076                      0.000001208                            10.29                             0.91                             5.49                             0.01
11/20/2013 10:37:10.317973	                      0.000000256                      0.000003098                      0.000001230                            12.58                             0.73                             5.49                             0.01
11/20/2013 10:37:11.317854	                      0.000000256                      0.000003120                      0.000001208                         12098.87                             6.77                            30.51                             0.01
11/20/2013 10:37:12.317785	                      0.000000253                      0.000003120                      0.000001208                          9037.53                             5.37                             8.54                             0.01
11/20/2013 10:37:13.318646	                      0.000000256                      0.000003120                      0.000001208                          6778.43                             4.08                             8.54                             0.01
11/20/2013 10:37:14.318517	                      0.000000258                      0.000003120                      0.000001208                          5105.28                             3.41                             3.05                             0.01
11/20/2013 10:37:15.318456	                      0.000000258                      0.000003120                      0.000001208                          3855.57                             2.86                             3.05                             0.01
11/20/2013 10:37:16.319259	                      0.000000256                      0.000003120                      0.000001230                          2921.72                             1.95                             0.61                             0.01
11/20/2013 10:37:17.319100	                      0.000000256                      0.000003120                      0.000001208                          2237.35                             1.58                             0.61                             0.01
11/20/2013 10:37:18.320004	                      0.000000253                      0.000003120                      0.000001230                          1826.50                             1.15                             1.83                             0.01
11/20/2013 10:37:19.320985	                      0.000000256                      0.000003120                      0.000001208                          1478.59                             1.15                             1.83                             0.01
11/20/2013 10:37:20.320764	                      0.000000258                      0.000003120                      0.000001208                          1197.07                             1.03                             3.66                             0.01
11/20/2013 10:37:21.320666	                      0.000000253                      0.000003120                      0.000001230                           969.32                             1.03                             3.66                             0.01
11/20/2013 10:37:22.321547	                      0.000000258                      0.000003120                      0.000001230                           785.07                             1.03                             4.27                             0.01
11/20/2013 10:37:23.322366	                      0.000000258                      0.000003120                      0.000001230                           635.15                             1.03                             4.27                             0.01
11/20/2013 10:37:24.322396	                      0.000000258                      0.000003120                      0.000001230                           513.84                             0.91                             4.27                             0.01
11/20/2013 10:37:25.322137	                      0.000000256                      0.000003120                      0.000001230                           415.42                             0.91                             4.27                             0.01
11/20/2013 10:37:26.321987	                      0.000000256                      0.000003142                      0.000001230                           335.31                             0.91                             4.88                             0.01
11/20/2013 10:37:27.321928	                      0.000000253                      0.000003120                      0.000001208                           270.08                             0.91                             4.88                             0.01
11/20/2013 10:37:28.322956	                      0.000000256                      0.000003098                      0.000001230                           216.29                             0.91                             4.88                             0.01
11/20/2013 10:37:29.323592	                      0.000000256                      0.000003098                      0.000001230                           179.67                             0.91                             4.88                             0.01
11/20/2013 10:37:30.323486	                      0.000000256                      0.000003142                      0.000001230                           141.90                             0.91                             4.88                             0.01
11/20/2013 10:37:31.323450	                      0.000000258                      0.000003120                      0.000001230                           108.72                             0.91                             4.88                             0.01
11/20/2013 10:37:32.323271	                      0.000000258                      0.000003120                      0.000001208                            89.26                             0.91                             4.88                             0.01
11/20/2013 10:37:33.324362	                      0.000000258                      0.000003098                      0.000001208                            70.95                             0.91                             4.88                             0.01
11/20/2013 10:37:34.324005	                      0.000000256                      0.000003120                      0.000001208                            53.78                             0.91                             5.49                             0.01
11/20/2013 10:37:35.323838	                      0.000000256                      0.000003120                      0.000001208                            53.78                             0.91                             1.83                             0.01
11/20/2013 10:37:36.324765	                      0.000000258                      0.000003120                      0.000001230                            33.18                             0.91                             1.83                             0.01
11/20/2013 10:37:37.324726	                      0.000000258                      0.000003120                      0.000001230                            17.16                             0.91                             1.22                             0.01
11/20/2013 10:37:38.325505	                      0.000000258                      0.000003120                      0.000001186                            17.16                             0.91                             1.22                             0.01
11/20/2013 10:37:39.325336	                      0.000000258                      0.000003098                      0.000001208                             4.57                             0.36                             1.22                             0.01
11/20/2013 10:37:40.325348	                      0.000000260                      0.000003120                      0.000001230                             4.57                             0.36                             1.22                             0.01
11/20/2013 10:37:41.325141	                      0.000000258                      0.000003120                      0.000001230                            12.58                             0.79                             1.22                             0.01
11/20/2013 10:37:42.325021	                      0.000000256                      0.000003120                      0.000001230                            12.58                             0.79                             1.22                             0.01
11/20/2013 10:37:43.325865	                      0.000000253                      0.000003120                      0.000001230                             9.15                             0.91                             0.61                             0.01
11/20/2013 10:37:44.325763	                      0.000000258                      0.000003120                      0.000001230                             9.15                             0.91                             0.61                             0.01
11/20/2013 10:37:45.325605	                      0.000000258                      0.000003098                      0.000001230                            10.29                             0.91                             0.61                             0.01
11/20/2013 10:37:46.325508	                      0.000000253                      0.000003120                      0.000001230                            10.29                             0.91                             0.61                             0.01
11/20/2013 10:37:47.325388	                      0.000000256                      0.000003098                      0.000001230                             5.72                             0.91                           998.55                             0.04
11/20/2013 10:37:48.326442	                      0.000000258                      0.000003120                      0.000001230                             5.72                             0.91                          3000.53                             0.09
11/20/2013 10:37:49.326181	                      0.000000256                      0.000003098                      0.000001252                             8.01                             0.91                          4500.80                             0.23
11/20/2013 10:37:50.325945	                      0.000000256                      0.000003120                      0.000001230                             8.01                             0.91                          5001.90                             0.23
11/20/2013 10:37:51.326819	                      0.000000256                      0.000003120                      0.000001230                             5.72                             0.91                          5568.93                             0.23
11/20/2013 10:37:52.326754	                      0.000000256                      0.000003120                      0.000001230                             5.72                             0.91                          7003.28                             0.23
11/20/2013 10:37:53.327593	                      0.000000256                      0.000003142                      0.000001230                             5.72                             0.91                          8003.66                             0.23
11/20/2013 10:37:54.327448	                      0.000000256                      0.000003120                      0.000001208                            13.73                             0.91                          9502.70                             0.53
11/20/2013 10:37:55.328351	                      0.000000260                      0.000003120                      0.000001230                            13.73                             0.91                         10506.14                             0.35
11/20/2013 10:37:56.328292	                      0.000000258                      0.000003120                      0.000001208                            17.16                             0.91                         11781.79                             0.38
11/20/2013 10:37:57.328116	                      0.000000256                      0.000003120                      0.000001208                            17.16                             0.91                         13006.17                             0.44
11/20/2013 10:37:58.328287	                      0.000000256                      0.000003120                      0.000001208                             9.15                             0.91                         14505.83                             0.44
11/20/2013 10:37:59.328830	                      0.000000256                      0.000003120                      0.000001208                             8.01                             0.91                         16503.54                             0.58
11/20/2013 10:38:00.328696	                      0.000000256                      0.000003120                      0.000001230                             8.01                             0.91                         18006.86                             0.58
11/20/2013 10:38:01.328586	                      0.000000256                      0.000003098                      0.000001230                            12.58                             0.91                         19506.52                             0.69
11/20/2013 10:38:02.329506	                      0.000000258                      0.000003098                      0.000001208                            12.58                             0.91                         21007.40                             0.79
11/20/2013 10:38:03.330336	                      0.000000258                      0.000003120                      0.000001208                            12.58                             0.91                         22507.66                             0.79
11/20/2013 10:38:04.330331	                      0.000000258                      0.000003098                      0.000001208                             4.57                             0.91                         23011.21                             0.80
11/20/2013 10:38:05.330125	                      0.000000256                      0.000003120                      0.000001208                             4.57                             0.91                         24009.15                             0.81
11/20/2013 10:38:06.329942	                      0.000000256                      0.000003120                      0.000001208                            12.58                             0.79                         25008.31                             0.81
11/20/2013 10:38:07.329857	                      0.000000258                      0.000003098                      0.000001208                            12.58                             0.79                         25010.14                             0.81
11/20/2013 10:38:08.330714	                      0.000000258                      0.000003098                      0.000001208                             5.72                             0.91                         25010.14                             0.81
11/20/2013 10:38:09.330602	                      0.000000260                      0.000003098                      0.000001230                             5.72                             0.91                         25011.97                             0.81
11/20/2013 10:38:10.330506	                      0.000000253                      0.000003098                      0.000001230                             5.72                             0.73                         25011.97                             0.81
11/20/2013 10:38:11.331338	                      0.000000258                      0.000003098                      0.000001230                             5.72                             0.73                         25011.97                             0.81
11/20/2013 10:38:12.331188	                      0.000000258                      0.000003120                      0.000001252                             6.86                             0.73                         25011.97                             0.81
11/20/2013 10:38:13.332192	                      0.000000258                      0.000003120                      0.000001252                             6.86                             0.73                         25011.97                             0.81
11/20/2013 10:38:14.331985	                      0.000000256                      0.000003120                      0.000001252                            10.29                             0.85                         25011.97                             0.81
11/20/2013 10:38:15.331812	                      0.000000256                      0.000003120                      0.000001208                            10.29                             0.85                         25012.58                             0.81
11/20/2013 10:38:16.331676	                      0.000000256                      0.000003120                      0.000001208                            13.73                             0.85                         25012.58                             0.81
11/20/2013 10:38:17.331599	                      0.000000258                      0.000003120                      0.000001208                            13.73                             0.85                         25012.58                             0.81
11/20/2013 10:38:18.331562	                      0.000000260                      0.000003098                      0.000001208                            10.29                             0.85                         25012.58                             0.81
11/20/2013 10:38:19.331349	                      0.000000256                      0.000003120                      0.000001230                            10.29                             0.85                         25012.58                             0.81
11/20/2013 10:38:20.331173	                      0.000000256                      0.000003120                      0.000001230                             8.01                             0.85                         25012.58                             0.81
11/20/2013 10:38:21.331084	                      0.000000258                      0.000003120                      0.000001230                            10.29                             0.85                         25012.58                             0.81
11/20/2013 10:38:22.331021	                      0.000000256                      0.000003120                      0.000001230                            10.29                             0.85                         25012.58                             0.81
11/20/2013 10:38:23.330936	                      0.000000256                      0.000003120                      0.000001230                             9.15                             0.85                         25012.58                             0.81
11/20/2013 10:38:24.330710	                      0.000000260                      0.000003120                      0.000001230                             9.15                             0.85                         25012.58                             0.81
11/20/2013 10:38:25.330593	                      0.000000256                      0.000003120                      0.000001208                             8.01                             0.73                         25012.58                             0.81
11/20/2013 10:38:26.330462	                      0.000000258                      0.000003120                      0.000001208                             8.01                             0.73                         25012.58                             0.81
11/20/2013 10:38:27.330338	                      0.000000256                      0.000003120                      0.000001208                            10.29                             0.91                         25012.58                             0.81
11/20/2013 10:38:28.331226	                      0.000000253                      0.000003120                      0.000001230                            10.29                             0.91                         25012.58                             0.81
11/20/2013 10:38:29.331092	                      0.000000258                      0.000003120                      0.000001230                            13.73                             0.91                         25012.58                             0.81
11/20/2013 10:38:30.331004	                      0.000000258                      0.000003098                      0.000001230                            13.73                             0.91                         25012.58                             0.81
11/20/2013 10:38:31.330795	                      0.000000258                      0.000003098                      0.000001208                             6.86                             0.91                         25012.58                             0.81
11/20/2013 10:38:32.330772	                      0.000000260                      0.000003120                      0.000001208                             6.86                             0.91                         25012.58                             0.81
11/20/2013 10:38:33.331565	                      0.000000260                      0.000003098                      0.000001208                             9.15                             0.79                         25012.58                             0.81
11/20/2013 10:38:34.331463	                      0.000000258                      0.000003098                      0.000001230                             9.15                             0.79                         25012.58                             0.81
11/20/2013 10:38:35.331347	                      0.000000256                      0.000003120                      0.000001208                            14.87                             0.61                         25012.58                             0.81
11/20/2013 10:38:36.331211	                      0.000000258                      0.000003120                      0.000001208                            14.87                             0.61                         25012.58                             0.81
11/20/2013 10:38:37.331045	                      0.000000258                      0.000003098                      0.000001230                            13.73                             0.85                         25012.58                             0.81
11/20/2013 10:38:38.330950	                      0.000000256                      0.000003098                      0.000001230                            13.73                             0.85                         25012.58                             0.81
11/20/2013 10:38:39.330833	                      0.000000258                      0.000003120                      0.000001186                             6.86                             0.73                         25012.58                             0.81
11/20/2013 10:38:40.330708	                      0.000000256                      0.000003120                      0.000001208                             6.86                             0.73                         25012.58                             0.81
11/20/2013 10:38:41.330581	                      0.000000258                      0.000003098                      0.000001230                             9.15                             0.85                         25012.58                             0.81
11/20/2013 10:38:42.330469	                      0.000000253                      0.000003098                      0.000001186                             6.86                             0.73                         25012.58                             0.81
11/20/2013 10:38:43.331408	                      0.000000256                      0.000003120                      0.000001230                             6.86                             0.85                         25012.58                             0.81
11/20/2013 10:38:44.331413	                      0.000000256                      0.000003120                      0.000001230                          1010.52                             2.99                         25012.58                             0.81
11/20/2013 10:38:45.332046	                      0.000000256                      0.000003120                      0.000001208                          1791.02                             5.61                         25012.58                             0.81
11/20/2013 10:38:46.331944	                      0.000000258                      0.000003098                      0.000001230                          2512.01                             3.90                         25012.58                             0.81
11/20/2013 10:38:47.331830	                      0.000000258                      0.000003120                      0.000001208                          3010.98                             9.94                         25012.58                             0.81
11/20/2013 10:38:48.332698	                      0.000000256                      0.000003120                      0.000001230                          4012.35                             4.51                         25012.58                             0.81
11/20/2013 10:38:49.332575	                      0.000000258                      0.000003120                      0.000001230                          5012.58                             7.75                         25012.58                             0.81
11/20/2013 10:38:50.332461	                      0.000000253                      0.000003098                      0.000001230                          6013.96                             6.65                         25012.58                             0.81
11/20/2013 10:38:51.332339	                      0.000000256                      0.000003098                      0.000001230                          7017.62                            11.41                         25012.58                             0.81
11/20/2013 10:38:52.332236	                      0.000000256                      0.000003098                      0.000001230                          8514.53                            10.43                         25012.58                             0.81
11/20/2013 10:38:53.333086	                      0.000000256                      0.000003098                      0.000001230                          9515.90                            17.09                         25012.58                             0.81
11/20/2013 10:38:54.332965	                      0.000000256                      0.000003098                      0.000001230                         11016.25                            14.95                         25012.58                             0.81
11/20/2013 10:38:55.332817	                      0.000000256                      0.000003120                      0.000001230                         12019.91                            16.35                         25012.58                             0.81
11/20/2013 10:38:56.332686	                      0.000000253                      0.000003098                      0.000001186                         13292.51                            16.41                         25012.58                             0.81
11/20/2013 10:38:57.332571	                      0.000000256                      0.000003120                      0.000001186                         14518.19                            15.93                         25012.58                             0.81
11/20/2013 10:38:58.333428	                      0.000000256                      0.000003120                      0.000001230                         15519.56                            15.68                         25012.58                             0.81
11/20/2013 10:38:59.333281	                      0.000000256                      0.000003120                      0.000001230                         16520.94                            16.11                         25012.58                             0.81
11/20/2013 10:39:00.333153	                      0.000000256                      0.000003098                      0.000001208                         18018.99                            24.23                         25012.58                             0.81
11/20/2013 10:39:01.333093	                      0.000000253                      0.000003142                      0.000001208                         19022.65                            22.70                         25012.58                             0.81
11/20/2013 10:39:02.333017	                      0.000000260                      0.000003120                      0.000001230                         20521.85                            21.30                         25012.58                             0.81
11/20/2013 10:39:03.333874	                      0.000000256                      0.000003098                      0.000001230                         22022.20                            23.25                         25012.58                             0.81
11/20/2013 10:39:04.333737	                      0.000000258                      0.000003098                      0.000001208                         23469.90                            26.06                         25012.58                             0.81
11/20/2013 10:39:05.333680	                      0.000000256                      0.000003120                      0.000001230                         24522.77                            24.71                         25012.58                             0.81
11/20/2013 10:39:06.333393	                      0.000000256                      0.000003120                      0.000001230                         26023.11                            28.99                         25012.58                             0.81
11/20/2013 10:39:07.333417	                      0.000000258                      0.000003120                      0.000001208                         27523.46                            29.35                         25012.58                             0.81
11/20/2013 10:39:08.334148	                      0.000000258                      0.000003120                      0.000001230                         29026.09                            31.31                         25012.58                             0.81
11/20/2013 10:39:09.334056	                      0.000000256                      0.000003120                      0.000001230                         30523.00                            32.53                         25012.58                             0.81
11/20/2013 10:39:10.333927	                      0.000000253                      0.000003120                      0.000001230                         31525.52                            31.67                         25012.58                             0.81
11/20/2013 10:39:11.333973	                      0.000000256                      0.000003120                      0.000001230                         32528.03                            30.15                         25012.58                             0.81
11/20/2013 10:39:12.334739	                      0.000000256                      0.000003120                      0.000001230                         33801.78                            36.19                         25012.58                             0.81
11/20/2013 10:39:13.335695	                      0.000000253                      0.000003120                      0.000001230                         35026.32                            35.33                         25012.58                             0.81
11/20/2013 10:39:14.335425	                      0.000000253                      0.000003120                      0.000001230                         36474.02                            39.06                         25012.58                             0.81
11/20/2013 10:39:15.336686	                      0.000000253                      0.000003098                      0.000001230                         37526.89                            38.20                         25012.58                             0.81
11/20/2013 10:39:16.337275	                      0.000000258                      0.000003098                      0.000001230                         38527.12                            38.20                         25012.58                             0.81
11/20/2013 10:39:17.338221	                      0.000000253                      0.000003098                      0.000001208                         39974.82                            39.61                         25012.58                             0.81
11/20/2013 10:39:18.338918	                      0.000000253                      0.000003098                      0.000001186                         41027.69                            41.44                         25012.58                             0.81
11/20/2013 10:39:19.338838	                      0.000000256                      0.000003098                      0.000001230                         42029.06                            41.74                         25012.58                             0.81
11/20/2013 10:39:20.338621	                      0.000000256                      0.000003098                      0.000001208                         43028.15                            49.80                         25012.58                             0.81
11/20/2013 10:39:21.338512	                      0.000000256                      0.000003098                      0.000001208                         44526.20                            53.40                         25012.58                             0.81
11/20/2013 10:39:22.338428	                      0.000000258                      0.000003098                      0.000001230                         45528.72                            48.34                         25012.58                             0.81
11/20/2013 10:39:23.339288	                      0.000000258                      0.000003098                      0.000001186                         46528.95                            48.46                         25012.58                             0.81
11/20/2013 10:39:24.339252	                      0.000000253                      0.000003098                      0.000001230                         47529.18                            52.36                         25012.58                             0.81
11/20/2013 10:39:25.339125	                      0.000000256                      0.000003098                      0.000001230                         48975.73                            52.67                         25012.58                             0.81
11/20/2013 10:39:26.338885	                      0.000000256                      0.000003120                      0.000001208                         50026.32                            52.85                         25012.58                             0.81
11/20/2013 10:39:27.338831	                      0.000000256                      0.000003098                      0.000001208                         51027.69                            55.35                         25012.58                             0.81
11/20/2013 10:39:28.339727	                      0.000000258                      0.000003120                      0.000001230                         52025.63                            56.09                         25012.58                             0.81
11/20/2013 10:39:29.339894	                      0.000000256                      0.000003120                      0.000001230                         53027.00                            56.45                         25012.58                             0.81
11/20/2013 10:39:30.340396	                      0.000000256                      0.000003120                      0.000001230                         54030.67                            62.74                         25012.58                             0.81
11/20/2013 10:39:31.340369	                      0.000000260                      0.000003120                      0.000001230                         54594.87                            66.28                         25012.58                             0.81
11/20/2013 10:39:32.340350	                      0.000000253                      0.000003120                      0.000001230                         55528.72                            64.69                         25012.58                             0.81
11/20/2013 10:39:33.341106	                      0.000000260                      0.000003120                      0.000001230                         56029.98                            69.58                         25012.58                             0.81
11/20/2013 10:39:34.340924	                      0.000000260                      0.000003098                      0.000001252                         56031.12                            69.09                         25012.58                             0.81
11/20/2013 10:39:35.340837	                      0.000000319                      0.000003758                      0.000001604                         56032.27                            68.90                         25012.58                             0.81
11/20/2013 10:39:36.340732	                      0.000000306                      0.000003714                      0.000001626                         56032.27                            70.61                         25012.58                             0.81
11/20/2013 10:39:37.341651	                      0.000000300                      0.000003582                      0.000001604                         56032.27                            69.88                         25012.58                             0.81
11/20/2013 10:39:38.342419	                      0.000000291                      0.000003538                      0.000001560                         56032.27                            67.68                         25012.58                             0.81
11/20/2013 10:39:39.342271	                      0.000000291                      0.000003494                      0.000001560                         56032.27                            68.54                         25012.58                             0.81
11/20/2013 10:39:40.342168	                      0.000000289                      0.000003494                      0.000001560                         56032.27                            68.17                         25012.58                             0.81
11/20/2013 10:39:41.341996	                      0.000000289                      0.000003472                      0.000001494                         56032.27                            66.77                         25012.58                             0.81
11/20/2013 10:39:42.341916	                      0.000000284                      0.000003450                      0.000001494                         56032.27                            67.99                         25012.58                             0.81
11/20/2013 10:39:43.342793	                      0.000000284                      0.000003450                      0.000001472                         56032.27                            66.10                         25012.58                             0.81
11/20/2013 10:39:44.342661	                      0.000000282                      0.000003384                      0.000001450                         56032.27                            67.01                         25012.58                             0.81
11/20/2013 10:39:45.342577	                      0.000000282                      0.000003384                      0.000001450                         56032.27                            67.32                         25012.58                             0.81
11/20/2013 10:39:46.343125	                      0.000000282                      0.000003362                      0.000001450                         56032.27                            67.13                         25012.58                             0.81
11/20/2013 10:39:47.343318	                      0.000000282                      0.000003384                      0.000001450                         56032.27                            65.24                         25012.58                             0.81
... 10427 more lines ...
  565   Tuesday, December 03, 2013, 14:14 Bevan MossConditioning StationStandard OperationTM2 HV conditioning

 It was attempted to HV condition TM2 to 55kV and leave it operating there for an hour to demonstrate stability. Unfortunately at 52.65kV a spark destroyed the canbus controller. This controller had shown issues in the past but seemed to magically fixed itself. I will contact Hubert for another card. Attached  is is a screen shot of the stip tools. 

Attachment 1: TM2_conditioning_03122013.JPG
TM2_conditioning_03122013.JPG
  575   Friday, December 06, 2013, 15:09 Bevan MossConditioning StationStandard OperationTM2 TM2 no source tray 55kV 1 hour

Today 55kV was applied to TM2 and held for over 1 hour with the EINZEL at 27.5kV. There were 2 sparks and the current was unstable at this voltage but this test should be considered a success. Once again while bringing the voltage up the canbus continued to be a problem. After successfully passing the test I continued to raise the BIAS and EINZEL. A spark at 57kV tripped a controller for the vacuum and the canbus. As stated before I believe the module will reach 60kV and that there is an interaction between the EINZEL and the BIAS. I am not certain if that interaction is internal or external to the module. Attached is a screen shot and the dumped data.

Attachment 1: 06122013_TM2_No_source_Tray_55kV_1_hour.JPG
06122013_TM2_No_source_Tray_55kV_1_hour.JPG
Attachment 2: 06122013_TM2_No_Source_Tray_55kV_1_Hour.txt
Time	TCS:IG1:RDVAC [T]	TCS:IG2:RDVAC [T]	TCS:IG1S:RDVAC [T]	TCS:DIC1:RDCOND [Mohm]	TCS:BIAS:RDVOL [V]	TCS:BIAS:RDCUR [uA]	TCS:EL:RDVOL [V]	TCS:EL:RDCUR [mA]	
12/06/2013 10:34:30.138858	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:31.138402	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:32.138289	                      0.000000093                      0.000001010                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:33.138127	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:34.138033	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:35.137874	                      0.000000093                      0.000000998                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:36.137749	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:37.137657	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:38.137550	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:39.138452	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:40.138322	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:41.138150	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:42.139015	                      0.000000094                      0.000000996                      0.000000768                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:43.138906	                      0.000000093                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:44.138797	                      0.000000093                      0.000000996                      0.000000765                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:45.138654	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:46.144533	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:47.144548	                      0.000000094                      0.000000998                      0.000000770                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:48.144363	                      0.000000093                      0.000000998                      0.000000768                           BadVal                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:49.144158	                      0.000000093                      0.000000996                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:50.144148	                      0.000000093                      0.000000996                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:51.144894	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:52.144785	                      0.000000093                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:53.144636	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:54.144483	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:55.157531	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:56.158254	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:57.158119	                      0.000000094                      0.000001032                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:58.157969	                      0.000000094                      0.000001010                      0.000000768                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:34:59.158877	                      0.000000093                      0.000000998                      0.000000768                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:00.159762	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:01.159615	                      0.000000094                      0.000000998                      0.000000770                             16.8                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:03.306946	                      0.000000093                      0.000000996                      0.000000768                             16.9                           BadVal                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:04.307252	                      0.000000094                      0.000000998                      0.000000768                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:05.308070	                      0.000000094                      0.000000998                      0.000000768                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:06.308956	                      0.000000094                      0.000000994                      0.000000770                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:07.308826	                      0.000000094                      0.000000994                      0.000000770                             16.9                            27.46                           BadVal                           BadVal                           BadVal
12/06/2013 10:35:08.308694	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:09.308573	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:10.309442	                      0.000000094                      0.000001010                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:11.309317	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:12.309197	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                           BadVal                           BadVal
12/06/2013 10:35:13.309123	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:14.308964	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:15.309987	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:16.309785	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                           BadVal
12/06/2013 10:35:17.309567	                      0.000000094                      0.000000996                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:18.422297	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:19.422322	                      0.000000094                      0.000000994                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:20.422292	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:21.422265	                      0.000000094                      0.000001010                      0.000000772                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:22.422985	                      0.000000094                      0.000001010                      0.000000772                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:23.532598	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:24.532696	                      0.000000094                      0.000000996                      0.000000772                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:25.700311	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:26.754388	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:27.754303	                      0.000000094                      0.000000996                      0.000000768                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:28.754164	                      0.000000094                      0.000000996                      0.000000768                             16.9                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:29.808485	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:30.808903	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:31.892662	                      0.000000093                      0.000000996                      0.000000772                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:32.892649	                      0.000000094                      0.000000994                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:33.892524	                      0.000000094                      0.000000994                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:34.892399	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:36.59457	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:37.59452	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:38.58995	                      0.000000094                      0.000000998                      0.000000768                             16.8                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:35:39.58868	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:40.58702	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:41.59611	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:42.59451	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:43.59465	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:44.69481	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             8.54                             0.01
12/06/2013 10:35:45.70113	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             8.54                             0.01
12/06/2013 10:35:46.69968	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:47.69843	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:48.69730	                      0.000000093                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:49.69609	                      0.000000093                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:50.69501	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:51.70349	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:52.70327	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:53.71064	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:54.71157	                      0.000000094                      0.000000996                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:55.70854	                      0.000000093                      0.000000998                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:56.70728	                      0.000000093                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:57.70696	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:58.71465	                      0.000000094                      0.000000998                      0.000000772                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:35:59.71304	                      0.000000094                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:00.72214	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:01.72058	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:02.72037	                      0.000000094                      0.000000996                      0.000000765                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:03.71845	                      0.000000093                      0.000000996                      0.000000768                             16.8                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:36:04.71718	                      0.000000093                      0.000000996                      0.000000770                             16.8                            26.32                             0.06                             9.15                             0.01
12/06/2013 10:36:05.71547	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:06.72545	                      0.000000094                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:07.72467	                      0.000000093                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:08.73208	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:09.73087	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:10.73946	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:11.74864	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:12.74666	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:13.75645	                      0.000000093                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:14.75641	                      0.000000093                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:15.75369	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:16.136319	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:17.136267	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:18.230037	                      0.000000094                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:19.229817	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:20.229681	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:21.229580	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:22.229431	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:23.229311	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:24.229201	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:25.229010	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:26.228930	                      0.000000094                      0.000000994                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:27.273591	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:28.273699	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:29.274782	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:30.274160	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:31.274279	                      0.000000094                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:32.274186	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:33.276910	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:34.276923	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:35.277751	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:36.277627	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:37.277496	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:38.277402	                      0.000000093                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:39.277265	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:40.277272	                      0.000000093                      0.000001010                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:41.278116	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:42.277876	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:43.277804	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:44.277667	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:45.277528	                      0.000000094                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:46.279324	                      0.000000094                      0.000000998                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:47.279479	                      0.000000093                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:48.280171	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:49.280032	                      0.000000094                      0.000000998                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:50.279918	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:51.280727	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:52.280665	                      0.000000093                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:53.280477	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:54.280361	                      0.000000093                      0.000000996                      0.000000770                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:55.280370	                      0.000000094                      0.000000994                      0.000000770                             16.7                            27.46                             0.06                             9.76                             0.01
12/06/2013 10:36:56.281267	                      0.000000094                      0.000000996                      0.000000768                             16.7                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:57.281021	                      0.000000093                      0.000000996                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:58.280911	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:36:59.280785	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:00.280647	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:01.281537	                      0.000000094                      0.000000996                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:02.281408	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:03.281254	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:04.281106	                      0.000000094                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:05.281008	                      0.000000093                      0.000000998                      0.000000768                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:06.281889	                      0.000000094                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:07.281764	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:08.281734	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:09.281500	                      0.000000093                      0.000000998                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:10.281385	                      0.000000094                      0.000000994                      0.000000770                             16.8                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:11.282277	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.76                             0.01
12/06/2013 10:37:12.282243	                      0.000000093                      0.000000998                      0.000000768                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:13.282030	                      0.000000094                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:14.281905	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:15.281781	                      0.000000093                      0.000000998                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:16.282607	                      0.000000093                      0.000000996                      0.000000770                             16.9                            27.46                             0.06                             9.15                             0.01
12/06/2013 10:37:17.282622	                      0.000000093                      0.000000998                      0.000000768                             16.9                             6.86                             1.03                             9.15                             0.01
12/06/2013 10:37:18.282434	                      0.000000094                      0.000000998                      0.000000770                             16.9                             6.86                             1.03                             1.22                             0.01
12/06/2013 10:37:19.282257	                      0.000000094                      0.000000998                      0.000000770                             16.9                             3.43                             1.03                             1.22                             0.01
12/06/2013 10:37:20.282499	                      0.000000094                      0.000000998                      0.000000770                             16.9                             4.57                             1.03                             1.83                             0.01
12/06/2013 10:37:21.283005	                      0.000000094                      0.000000998                      0.000000770                             16.9                             4.57                             1.03                           493.17                             0.01
12/06/2013 10:37:22.283870	                      0.000000093                      0.000000998                      0.000000770                             16.9                             4.57                             1.03                           993.05                             0.01
12/06/2013 10:37:23.283923	                      0.000000094                      0.000000998                      0.000000770                             16.9                             6.86                             0.91                          1494.16                             0.01
12/06/2013 10:37:24.283648	                      0.000000093                      0.000000996                      0.000000770                             16.9                             3.43                             1.15                          1494.16                             0.01
12/06/2013 10:37:25.283492	                      0.000000094                      0.000000998                      0.000000770                             16.9                            13.73                             1.15                          1994.04                             0.28
12/06/2013 10:37:26.283509	                      0.000000094                      0.000000998                      0.000000770                             16.9                            13.73                             1.15                          1994.04                             0.08
12/06/2013 10:37:27.283262	                      0.000000093                      0.000000998                      0.000000770                             16.8                             5.72                             0.85                          2494.54                             0.10
12/06/2013 10:37:28.283071	                      0.000000093                      0.000000998                      0.000000770                             16.8                             2.28                             0.97                          2995.04                             0.10
12/06/2013 10:37:29.282990	                      0.000000094                      0.000000998                      0.000000770                             16.8                             2.28                             0.97                          3495.53                             0.10
12/06/2013 10:37:30.282877	                      0.000000093                      0.000000998                      0.000000770                             16.8                            10.29                             0.97                          3994.81                             0.15
12/06/2013 10:37:31.283728	                      0.000000094                      0.000000996                      0.000000768                             16.8                             8.01                             0.91                          3994.81                             0.15
12/06/2013 10:37:32.283568	                      0.000000094                      0.000000998                      0.000000768                             16.8                             4.57                             1.15                          3996.03                             0.15
12/06/2013 10:37:33.283508	                      0.000000093                      0.000000998                      0.000000770                             16.8                             6.86                             1.15                          3996.03                             0.15
12/06/2013 10:37:34.283108	                      0.000000094                      0.000000998                      0.000000768                             16.8                             4.57                             1.03                          3996.03                             0.15
12/06/2013 10:37:35.283283	                      0.000000094                      0.000000998                      0.000000768                             16.8                             5.72                             1.03                          3996.03                             0.15
12/06/2013 10:37:36.284116	                      0.000000093                      0.000000994                      0.000000768                             16.8                             5.72                             1.09                          3996.03                             0.15
12/06/2013 10:37:37.283983	                      0.000000094                      0.000000998                      0.000000770                             16.8                             5.72                             1.09                          3996.64                             0.15
12/06/2013 10:37:38.283864	                      0.000000094                      0.000000998                      0.000000770                             16.7                             3.43                             1.09                          3996.03                             0.15
12/06/2013 10:37:39.472917	                      0.000000094                      0.000000998                      0.000000765                             16.7                             3.43                             1.09                          3996.64                             0.15
12/06/2013 10:37:40.472581	                      0.000000093                      0.000000996                      0.000000768                             16.7                             2.28                             1.15                          3996.64                             0.15
12/06/2013 10:37:41.472472	                      0.000000094                      0.000000998                      0.000000770                             16.7                             2.28                             1.15                          3996.64                             0.15
12/06/2013 10:37:42.472333	                      0.000000094                      0.000000998                      0.000000768                             16.8                             8.01                             1.03                          3996.64                             0.15
12/06/2013 10:37:43.472212	                      0.000000094                      0.000000998                      0.000000770                             16.8                             8.01                             1.03                          3996.64                             0.15
12/06/2013 10:37:44.738171	                      0.000000094                      0.000000998                      0.000000770                             16.8                             9.15                             1.03                          3996.64                             0.15
12/06/2013 10:37:45.737929	                      0.000000093                      0.000000998                      0.000000770                             16.8                             9.15                             1.03                          3996.03                             0.15
12/06/2013 10:37:46.737758	                      0.000000093                      0.000000996                      0.000000768                             16.8                            10.29                             1.03                          3996.64                             0.15
12/06/2013 10:37:47.737679	                      0.000000094                      0.000000996                      0.000000770                             16.8                             8.01                             0.91                          3996.64                             0.15
12/06/2013 10:37:48.737550	                      0.000000094                      0.000000998                      0.000000768                             16.8                             5.72                             1.15                          3996.64                             0.15
12/06/2013 10:37:49.737448	                      0.000000094                      0.000000998                      0.000000768                             16.8                             5.72                             1.15                          4276.79                             0.15
12/06/2013 10:37:50.737254	                      0.000000094                      0.000000998                      0.000000770                             16.8                             3.43                             0.97                          4997.02                             0.15
12/06/2013 10:37:51.738371	                      0.000000093                      0.000000996                      0.000000770                             16.8                            12.58                             0.91                          5997.40                             0.44
12/06/2013 10:37:52.739018	                      0.000000094                      0.000000996                      0.000000770                             16.8                            12.58                             1.15                          7996.33                             0.49
12/06/2013 10:37:53.739981	                      0.000000094                      0.000000998                      0.000000770                             16.9                             1.14                             1.15                          9499.65                             0.29
12/06/2013 10:37:54.739743	                      0.000000094                      0.000000998                      0.000000770                             16.9                             1.14                             1.15                         10997.48                             0.59
12/06/2013 10:37:55.739858	                      0.000000094                      0.000000996                      0.000000770                             16.9                            14.87                             1.15                         11999.69                             0.42
12/06/2013 10:37:56.740534	                      0.000000094                      0.000001010                      0.000000770                             16.9                            14.87                             1.15                         13499.35                             0.47
12/06/2013 10:37:57.740392	                      0.000000094                      0.000000998                      0.000000765                             16.9                             3.43                             1.15                         15000.83                             0.49
12/06/2013 10:37:58.740247	                      0.000000094                      0.000000998                      0.000000768                             16.8                             3.43                             1.15                         16499.88                             0.57
12/06/2013 10:37:59.740213	                      0.000000094                      0.000000998                      0.000000768                             16.8                            12.58                             1.15                         18001.98                             0.63
12/06/2013 10:38:00.740039	                      0.000000093                      0.000000998                      0.000000768                             16.8                            12.58                             1.15                         19068.89                             0.65
12/06/2013 10:38:01.739890	                      0.000000093                      0.000000998                      0.000000774                             16.8                            10.29                             0.97                         20003.35                             0.65
12/06/2013 10:38:02.739822	                      0.000000093                      0.000000998                      0.000000770                             16.8                            10.29                             0.97                         20003.35                             0.65
12/06/2013 10:38:03.740608	                      0.000000093                      0.000000998                      0.000000770                             16.8                          1007.09                             4.08                         20005.18                             0.65
12/06/2013 10:38:04.740535	                      0.000000094                      0.000000998                      0.000000768                             16.8                          2009.61                             2.38                         20005.18                             0.65
12/06/2013 10:38:05.740421	                      0.000000094                      0.000000998                      0.000000768                             16.8                          3292.51                             4.33                         20005.18                             0.65
12/06/2013 10:38:06.741299	                      0.000000093                      0.000000998                      0.000000770                             16.8                          4510.18                             7.87                         20005.18                             0.65
12/06/2013 10:38:07.741154	                      0.000000094                      0.000000998                      0.000000770                             16.8                          5794.23                             7.01                         20005.79                             0.65
12/06/2013 10:38:08.740978	                      0.000000094                      0.000000994                      0.000000770                             16.8                          7014.19                            10.80                         20005.79                             0.65
12/06/2013 10:38:09.740907	                      0.000000093                      0.000000998                      0.000000768                             16.8                          8294.80                            13.91                         20005.79                             0.65
12/06/2013 10:38:10.741753	                      0.000000093                      0.000000998                      0.000000768                             16.8                         10017.16                            14.58                         20005.79                             0.65
12/06/2013 10:38:11.742650	                      0.000000094                      0.000000996                      0.000000770                             16.8                         11519.79                            19.28                         20005.79                             0.65
12/06/2013 10:38:12.742528	                      0.000000093                      0.000000996                      0.000000770                             16.8                         12021.05                            12.81                         20005.79                             0.65
12/06/2013 10:38:13.742395	                      0.000000093                      0.000000998                      0.000000770                             16.8                         12522.31                            12.08                         20005.79                             0.65
12/06/2013 10:38:14.742226	                      0.000000093                      0.000000998                      0.000000770                             16.8                         13021.28                            12.26                         20005.79                             0.65
12/06/2013 10:38:15.742200	                      0.000000094                      0.000000998                      0.000000768                             16.8                         13801.78                            12.57                         20005.79                             0.65
12/06/2013 10:38:16.742099	                      0.000000094                      0.000000998                      0.000000770                             16.8                         14522.77                            17.39                         20005.79                             0.65
12/06/2013 10:38:17.742891	                      0.000000093                      0.000000996                      0.000000768                             16.8                         15024.03                            15.80                         20005.79                             0.65
12/06/2013 10:38:18.742772	                      0.000000093                      0.000000998                      0.000000768                             16.8                         15524.14                            14.89                         20005.79                             0.65
12/06/2013 10:38:19.742602	                      0.000000093                      0.000000998                      0.000000768                             16.8                         16524.37                            18.73                         20005.79                             0.65
12/06/2013 10:38:20.742477	                      0.000000093                      0.000000998                      0.000000768                             16.8                         17026.77                            17.27                         20005.79                             0.65
12/06/2013 10:38:21.743352	                      0.000000093                      0.000000996                      0.000000770                             16.8                         18030.44                            20.81                         20005.79                             0.65
12/06/2013 10:38:22.743286	                      0.000000093                      0.000000996                      0.000000770                             16.8                         18527.12                            18.67                         20005.79                             0.65
12/06/2013 10:38:23.743116	                      0.000000093                      0.000000998                      0.000000770                             16.8                         19528.49                            22.64                         20005.79                             0.65
12/06/2013 10:38:24.743988	                      0.000000093                      0.000000996                      0.000000765                             16.8                         20029.75                            21.17                         20005.79                             0.65
12/06/2013 10:38:25.743892	                      0.000000093                      0.000000996                      0.000000768                             16.8                         20529.86                            20.38                         20005.79                             0.65
12/06/2013 10:38:26.744754	                      0.000000093                      0.000000998                      0.000000770                             16.8                         21530.09                            25.63                         20005.79                             0.65
12/06/2013 10:38:27.744640	                      0.000000094                      0.000000998                      0.000000768                             16.8                         22031.35                            23.49                         20005.79                             0.65
12/06/2013 10:38:28.744504	                      0.000000093                      0.000000998                      0.000000768                             16.8                         22532.61                            22.94                         20005.79                             0.65
12/06/2013 10:38:29.745410	                      0.000000094                      0.000000998                      0.000000768                             16.8                         23032.73                            22.70                         20005.79                             0.65
12/06/2013 10:38:30.745262	                      0.000000094                      0.000000998                      0.000000770                             16.8                         23533.98                            27.52                         20005.79                             0.65
12/06/2013 10:38:31.745131	                      0.000000094                      0.000000996                      0.000000772                             16.8                         24533.07                            26.36                         20005.79                             0.65
12/06/2013 10:38:32.745008	                      0.000000094                      0.000000998                      0.000000768                             16.7                         25034.33                            25.63                         20005.79                             0.65
12/06/2013 10:38:33.745050	                      0.000000093                      0.000000998                      0.000000770                             16.7                         26034.56                            29.90                         20005.79                             0.65
12/06/2013 10:38:34.744755	                      0.000000094                      0.000001010                      0.000000768                             16.7                         26535.82                            28.25                         20005.79                             0.65
12/06/2013 10:38:35.744622	                      0.000000093                      0.000000998                      0.000000770                             16.7                         27035.93                            27.34                         20005.79                             0.65
12/06/2013 10:38:36.745477	                      0.000000093                      0.000000998                      0.000000768                             16.7                         27989.24                            31.73                         20005.79                             0.65
12/06/2013 10:38:37.746375	                      0.000000093                      0.000000998                      0.000000768                             16.7                         28536.27                            30.94                         20005.79                             0.65
12/06/2013 10:38:38.746259	                      0.000000094                      0.000000998                      0.000000770                             16.7                         29037.53                            30.88                         20005.79                             0.65
12/06/2013 10:38:39.746094	                      0.000000094                      0.000000996                      0.000000770                             16.7                         29538.79                            30.51                         20005.79                             0.65
12/06/2013 10:38:40.746006	                      0.000000093                      0.000000998                      0.000000768                             16.7                         30038.91                            30.45                         20005.79                             0.65
12/06/2013 10:38:41.745828	                      0.000000093                      0.000000998                      0.000000770                             16.7                         30539.02                            30.70                         20005.79                             0.65
12/06/2013 10:38:42.745708	                      0.000000093                      0.000000994                      0.000000768                             16.7                         31040.28                            31.55                         20005.79                             0.65
12/06/2013 10:38:43.746645	                      0.000000094                      0.000000994                      0.000000770                             16.7                         31993.59                            36.07                         20005.79                             0.65
12/06/2013 10:38:44.746538	                      0.000000093                      0.000000998                      0.000000765                             16.7                         32540.62                            35.82                         20005.79                             0.65
12/06/2013 10:38:45.746327	                      0.000000093                      0.000000998                      0.000000765                             16.7                         33040.74                            35.15                         20005.79                             0.65
12/06/2013 10:38:46.747194	                      0.000000093                      0.000001010                      0.000000770                             16.7                         33540.85                            34.79                         20005.79                             0.65
12/06/2013 10:38:47.747076	                      0.000000093                      0.000000996                      0.000000770                             16.7                         34545.66                            38.81                         20005.79                             0.65
12/06/2013 10:38:48.746949	                      0.000000093                      0.000000998                      0.000000768                             16.7                         35042.34                            37.17                         20005.79                             0.65
12/06/2013 10:38:49.747854	                      0.000000094                      0.000000998                      0.000000770                             16.8                         36041.42                            46.81                         20005.79                             0.65
12/06/2013 10:38:50.747794	                      0.000000093                      0.000000996                      0.000000768                             16.8                         36543.83                            40.03                         20005.79                             0.65
12/06/2013 10:38:51.748607	                      0.000000094                      0.000000998                      0.000000770                             16.8                         37043.94                            39.61                         20005.79                             0.65
12/06/2013 10:38:52.748492	                      0.000000093                      0.000000998                      0.000000770                             16.8                         37545.20                            39.73                         20005.79                             0.65
12/06/2013 10:38:53.748395	                      0.000000093                      0.000000998                      0.000000768                             16.8                         38046.46                            44.06                         20005.79                             0.65
12/06/2013 10:38:54.748195	                      0.000000093                      0.000000996                      0.000000768                             16.8                         39044.40                            43.03                         20005.79                             0.65
12/06/2013 10:38:55.748153	                      0.000000094                      0.000000998                      0.000000770                             16.8                         39545.66                            43.45                         20005.79                             0.65
12/06/2013 10:38:56.749112	                      0.000000094                      0.000000998                      0.000000770                             16.8                         39545.66                            40.89                         20005.79                             0.65
12/06/2013 10:38:57.748818	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40046.92                            41.50                         20005.79                             0.65
12/06/2013 10:38:58.748731	                      0.000000093                      0.000000998                      0.000000768                             16.8                         40046.92                            41.07                         20005.79                             0.65
12/06/2013 10:38:59.748612	                      0.000000094                      0.000000996                      0.000000768                             16.8                         40046.92                            40.89                         20005.79                             0.65
12/06/2013 10:39:00.748440	                      0.000000094                      0.000000996                      0.000000768                             16.8                         40046.92                            40.89                         20005.79                             0.65
12/06/2013 10:39:01.749351	                      0.000000094                      0.000001010                      0.000000770                             16.8                         40046.92                            40.89                         20005.79                             0.65
12/06/2013 10:39:02.749233	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.83                         20006.40                             0.65
12/06/2013 10:39:03.749082	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.83                         20006.40                             0.65
12/06/2013 10:39:04.749026	                      0.000000093                      0.000000998                      0.000000765                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:05.749899	                      0.000000094                      0.000000998                      0.000000768                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:06.750723	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:07.750716	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40046.92                            40.83                         20005.79                             0.65
12/06/2013 10:39:08.750436	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.83                         20005.79                             0.65
12/06/2013 10:39:09.750420	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40046.92                            41.32                         20005.79                             0.65
12/06/2013 10:39:10.750265	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:11.751047	                      0.000000093                      0.000000996                      0.000000768                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:12.750973	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:13.751821	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:14.751678	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:15.751659	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         20005.79                             0.65
12/06/2013 10:39:16.752539	                      0.000000094                      0.000000998                      0.000000772                             16.8                         40048.06                            40.71                         20503.85                             0.71
12/06/2013 10:39:17.753413	                      0.000000094                      0.000000996                      0.000000770                             16.8                         40048.06                            40.71                         21004.34                             0.71
12/06/2013 10:39:18.753168	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         21504.23                             0.71
12/06/2013 10:39:19.753173	                      0.000000093                      0.000000998                      0.000000772                             16.7                         40048.06                            40.58                         22070.64                             0.76
12/06/2013 10:39:20.752945	                      0.000000093                      0.000000994                      0.000000768                             16.7                         40048.06                            40.58                         23000.83                             0.99
12/06/2013 10:39:21.753831	                      0.000000094                      0.000000996                      0.000000772                             16.7                         40048.06                            40.58                         23503.16                             0.80
12/06/2013 10:39:22.753731	                      0.000000093                      0.000000996                      0.000000772                             16.7                         40048.06                            40.58                         24003.66                             0.80
12/06/2013 10:39:23.753588	                      0.000000093                      0.000000996                      0.000000770                             16.7                         40048.06                            40.58                         24501.71                             0.85
12/06/2013 10:39:24.754474	                      0.000000094                      0.000000998                      0.000000765                             16.7                         40048.06                            40.58                         25003.43                             0.87
12/06/2013 10:39:25.754339	                      0.000000094                      0.000000998                      0.000000770                             16.7                         40048.06                            40.71                         25503.31                             0.87
12/06/2013 10:39:26.754168	                      0.000000094                      0.000000998                      0.000000772                             16.7                         40048.06                            40.71                         25953.15                             0.87
12/06/2013 10:39:27.754087	                      0.000000093                      0.000000998                      0.000000772                             16.8                         40048.06                            40.71                         26003.20                             0.87
12/06/2013 10:39:28.754026	                      0.000000094                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         26503.70                             0.99
12/06/2013 10:39:29.753829	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         26572.67                             0.99
12/06/2013 10:39:30.753655	                      0.000000093                      0.000000998                      0.000000770                             16.8                         40048.06                            40.71                         27503.47                             0.95
... 14427 more lines ...
  578   Thursday, December 12, 2013, 11:14 Bevan MossConditioning StationStandard OperationTM2 HV Chase Electrical Test

While under vacuum Travis and I completed diagnostics of the HV chase. Majority of the lines showed OL at 1kV but there were the following "failures"

A to P @ 250V 716kOhm
A to Q @ 1kV 25.18MOhm
B to C with ohm meter 8Mohm @250V 830kOhm
B to D @ 1kV 15.57MOhm
C to D @1kV 16.18 MOhm
P to Q @1kV 1.069 GOhm
G to J with ohm meter dead short.

Ideally all of these values would be OL and they may improve or get worse when the source tray is installed depending on where the electrical contact is. I need to discuss with Friedhelm but I believe that as these values the module can still operate. Without changing the HV chase there is very little chance of improving these values.

  589   Thursday, January 30, 2014, 13:46 Travis CaveConditioning StationStandard OperationTM2no targetmodule move

TM#2 has been moved from the conditioning station to the south hot cell.

  601   Monday, February 17, 2014, 09:32 David WangConditioning StationRepairTM2 helium pressure test on TM2 tube heater +(D) water line.

I did the helium pressure test on Tube heater+ line this morning. The vacuum on CS and TM2 are very good. The base lake rate on leak detector was 1.7xE-7 atm.cc/sec. Base pressure was 0.0xE-4torr.  I applied helium to the "D"line .The test started from 30psi up to 80psi on both side "D" line.The base leak rate slightly changed to 1.9xE-7 atm.cc/sec during the test,but not base pressure. At this base leak rate level, No obvious leak had been found . See attachment pictures. The test will be repeated later when the base leak rate could be pumped into E -8 or E-9(the best) range.            

Attachment 1: 002.JPG
002.JPG
Attachment 2: 003.JPG
003.JPG
Attachment 3: 004.JPG
004.JPG
Attachment 4: 012.JPG
012.JPG
Attachment 5: 016.JPG
016.JPG
Attachment 6: 018.JPG
018.JPG
  602   Tuesday, February 18, 2014, 11:26 David WangConditioning StationRepairTM2 I stopped turbo pumps and disconnected vacuum system on TM 2 and CS

I stopped turbo pumps and disconnected vacuum system on TM2 and CS. The TM2 will be moved to SHC for C seal installation on "D" water block.

  603   Thursday, February 20, 2014, 09:45 Travis CaveConditioning StationStandard OperationTM2no targetmodule move

TM#2 has been moved from the conditioning station to the south hot cell.

  609   Tuesday, February 25, 2014, 10:00 David WangConditioning StationRepairTM2 helium pressure test on TM2 tube heater (+) water line with blank off(C-seal) installed on WB.

I did the helium pressure  test  on TM2 tube heater (+) water line  with blank off(C-seal) installed on  water block at CS.The leak detector was hooked directly to the top of the module this time. So base leak rate and base pressure were at the bottom scale on LD. 30 -80 psi helium was applied to the D lines(both side)  with10 psi   increasing each time. There is no any tiny response hasbeen found during the test. The lines are perfectly sealed. Also i sprayed the helium on the top of the service cap .All  air to vacuum seals on the top are good either. See attachment pictures.

Attachment 1: 004.JPG
004.JPG
Attachment 2: 005.JPG
005.JPG
Attachment 3: 006.JPG
006.JPG
Attachment 4: 007.JPG
007.JPG
Attachment 5: 008.JPG
008.JPG
Attachment 6: 009.JPG
009.JPG
Attachment 7: 010.JPG
010.JPG
Attachment 8: 011.JPG
011.JPG
Attachment 9: 017.JPG
017.JPG
Attachment 10: 019.JPG
019.JPG
  611   Wednesday, March 05, 2014, 10:07 Travis CaveConditioning StationStandard OperationTM2no targetmodule move

TM#2 with no target or source tray has been moved from the conditioning station to the north east silo. TM#1 with no target has been moved into the conditioning station.

  612   Thursday, March 06, 2014, 06:28 David WangConditioning StationMaintenanceTM1 TM1 had been moved from silo to CS

TM1 has been successfully moved from silo to CS. The CS vacuum system is connected  to TM1. Turbo pumps on TM1 and CS have been started yesterday afternoon . The starting of TM1 turbos was easy. The pumping down over night is good so far.

  614   Thursday, March 06, 2014, 12:59 David WangConditioning StationMaintenanceTM1 Restart TM1 and CS TPs

Restarted TM1 and CS turbo pumps after the power off. Everything is fine .

  615   Thursday, March 06, 2014, 14:12 David WangConditioning StationStandard OperationTM1 TM1 air to vacuum and water lines leak check at CS.

TM1 air to vacuum and water lines leak check at CS are finished this afternoon. The leak detector  is hooked directly to TM1 service cap so the base LR at LD is 0.0xE-9 atm.cc/sec. I sprayed helium to all air to vacuum seal on the service cap, also applied 70 psi to all water lines(except HS) for 2 minutes each. There is no any tiny response had been found on LD. So All TM1 water lines(except HS) and air to vacuum seals are leak free. The HS circuit can not be tested at this time since the VCR caps are not installed. The turbo pumps at CS and TM1 will be turned off before I leave.  See attachment pictures.

Attachment 1: 001.JPG
001.JPG
Attachment 2: 002.JPG
002.JPG
Attachment 3: 003.JPG
003.JPG
Attachment 4: 004.JPG
004.JPG
Attachment 5: 005.JPG
005.JPG
Attachment 6: 006.JPG
006.JPG
Attachment 7: 007.JPG
007.JPG
Attachment 8: 013.JPG
013.JPG
  627   Thursday, March 20, 2014, 08:19 Travis CaveConditioning StationStandard OperationTM1no targetmodule move

TM#1 with no target moved from the conditioning station to north west silo.

  633   Wednesday, March 26, 2014, 08:36 Travis CaveConditioning StationStandard OperationTM4Ta#42module move

TM#4 with Ta#42 has been moved from the south hot cell to the conditioning station.

  634   Thursday, March 27, 2014, 10:47 Travis CaveConditioning StationStandard OperationTM4Ta#42Electrical check

TM#4 with Ta#42 in the conditioning station under vacuum electrical check.

Attachment 1: TM#4_Ta42surf_electest_CS.PDF
TM#4_Ta42surf_electest_CS.PDF