Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Evaporator_1, Page 3 of 15  Not logged in ELOG logo
ID Datedown Author Target Material Target Oven W.O# Source Status Subject Text Attachments
  255   Thursday, January 30, 2020, 10:15 Marla CervantesUO2/CP2N-02 ProblemsP2N target material carbothermal reduction

    

       
            
  
  254   Thursday, January 30, 2020, 09:37 Marla CervantesUO2/CP2N-02 In progressP2N target material carbothermal reductionWednesday, January 29 2020, 05:55  
A P2N container  with
  
  253   Wednesday, January 29, 2020, 10:11 Marla CervantesEmptyP2N-02 DoneP2N test#2The assembly consists of two tantalum
foils, 0.001" thick, which are radially
crimped to form a cylindrical surface. The
 P2N-test2_final_voltage.JPGP2N-test2.JPG 
  252   Wednesday, January 22, 2020, 18:10 Marla CervantesEmptyP2N-02  DoneP2N test#1The assembly consists of two tantalum
foils, 0.001" thick, which are radially
crimped to form a cylindrical surface. The
 6x 
  251   Wednesday, November 06, 2019, 11:48 Marla CervantesUC244062-3 LP-SISDoneUCx#30 Conditioning Tuesday, November 05, 2019, 16:43
A TaC coated target container 
  
  250   Tuesday, November 05, 2019, 14:50 Aaron Schmidt   MaintenanceFallen Bolt. One of the TBHT bolts  fell out of reach   
  249   Thursday, October 31, 2019, 13:59 Marla CervantesUO2/C TARGET BOATProblemsUCx#30 Carbothermal Reduction

    

       
            
  
  248   Monday, October 28, 2019, 11:23 Marla CervantesUO2/C TARGET BOATIn progressUCx#30 Carbothermal ReductionMonday, October 28, 2019, 10:29
A loaded graphite cartridge was set
in a tantalum boated and wrapped with 3 tantalum
 UCx30-CarbothramlReduction.JPGUCx30-CurrentDrop.JPG 
  247   Tuesday, October 08, 2019, 09:53 Marla CervantesUC244062-6LP-SISDoneUCx29 ConditioningMonday, October 07, 2019, 09:51 
A TaC coated target
  
  246   Wednesday, October 02, 2019, 11:10 Marla CervantesUO2/C TARGET BOATDoneUCx#29 Carbothermal reduction Wednesday, October 02, 2019, 11:09
A graphite cartridge loaded with
UO2/C foils, wrapped with three Ta heat shields
 CarbothermalReduction-UCx29.JPG 
  245   Wednesday, October 02, 2019, 11:07 Marla CervantesUC244062-4LP-SISDoneUCx28 Conditioning #5Monday, September 30, 2019, 10:54 
After being exposed to air for 1.5
hours,
  
  244   Friday, September 27, 2019, 18:04 Marla CervantesUC244062-4LP-SISDoneUCx28 Conditioning #4Friday, September 27, 2019, 18:03
The target UCx28 that
 IMG_1393.JPG 
  243   Wednesday, September 25, 2019, 14:00 Marla CervantesUC244062-4LP-SISDoneUCx28 Conditioning #3Wednesday, September 25, 2019, 14:00 
The target UCx28 that
  
  242   Tuesday, September 24, 2019, 06:53 Marla CervantesUC244062-4LP-SISDoneUCx28 Conditioning #2 Tuesday, September 24, 2019, 06:52
The target UCx28 that was previously
  
  241   Wednesday, September 18, 2019, 09:57 Marla CervantesUC244062-4LP-SISDoneUCx28 Conditioning #1Wednesday, September 18, 2019, 07:48
A TaC coated target container 
was loaded with a graphite cartridge with
  
  240   Tuesday, July 30, 2019, 10:27 Marla CervantesUO2/C TARGET BOATDoneUCx#28 Carbothermal reductionFriday,
June 26, 2019, 17:10
 UCx28.JPG 
  239   Monday, June 17, 2019, 08:58 Marla CervantesUO2/C TARGET BOATDoneUCx#27 Carbothermal reductionFriday, June 14, 2019, 17:10
A 14 mm die was used to cut
  
  238   Friday, May 24, 2019, 15:25 Marla Cervantes 43943-1 DoneGraphite insert test - FOILS Friday, May 24, 2019, 15:04
A TaC coated tantalum tube, loaded
with graphite foils was transferred to EVAP1
  
  237   Wednesday, April 10, 2019, 13:38 Marla Cervantes 43630-3  DoneGraphite insert test #6 Wednesday, April 10, 2019, 13:30
Tantalum foil caps were added to
a graphite insert (see picture caps)
 caps.jpgCurren-voltage-plot.JPG 
  236   Friday, April 05, 2019, 10:08 Marla Cervantes 43630-3 DoneTaC coating/sintering for graphite insert test Friday, April 05, 2019, 10:04
A tantalum tube was coated
 EVAP1-TaC_Coating.JPG 
ELOG V2.9.2-2455