Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Evaporator_1, Page 11 of 15  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
  ID Date Author Target Materialdown Target Oven W.O# Source Status Subject Text Attachments
  274   Wednesday, September 15, 2021, 07:19 Marla CervantesUC2 TARGET BOATDoneConditioning 2sc samplesWednesday, September 14, 2021, 21:14
Boat is wrapped with 2 layers
  
  279   Wednesday, April 13, 2022, 10:55 Luca EgoritiUC2 P2N-SISDoneP2N carbothermal reduction P2Ncartridge-220323Wednesday, April 13, 2022, 10:50
P2NC-220323
Preparing the P2N-UCx for online
  
  280   Wednesday, May 04, 2022, 09:47 Luca EgoritiUC2 P2N-SISDoneP2N carbothermal reduction P2NC220408 Wednesday, May 04, 2022, 09:42
Yesterday, a second graphite cartridge
was installed in EVAP1, it consists of the
  
  285   Wednesday, October 19, 2022, 12:28 Darwin Ortiz RosalesUC240253-5LP TUBEDoneC-220510 further conditioningWednesday, October 19, 2022, 10:27
Cartridge-220510Cx was installed
  
  96   Friday, July 04, 2014, 10:23 John WongThO240282-2TARGET BOATDoneTest: Sintering ThO2 with Nb backing foils Friday, July 04, 2014, 10:13
Target boat contains 4 set of samples. 
Each sample consists of 5pack ThO2/Nb. 
 2014-07-03_12.29.29.jpgThO_raw_green_sintered_30um.pngpressure_current_plot.PNG 
  97   Wednesday, July 09, 2014, 13:57 Laura LambertThO240282-2TARGET BOATDoneTest: Sintering ThO2 with Nb backing foils

    

       
            
 test_batch_full_sintering.JPGjul9_2014_(2).jpg 
  98   Thursday, August 14, 2014, 17:56 John WongThO2 LP-SISDoneSintering ThO2#1 Thursday, August 14, 2014, 17:54
Target container consists of 240
discs of ThO2/Nb discs.  The container
  
  34   Wednesday, September 07, 2011, 13:41 John WongTaC38634-6LP-SISDoneTaC#1: Sintering and Organics burn-off Wednesday, September 07, 2011, 15:31
125 discs of TaC/C
Total discs mass = 125
 TaC#1.jpgendcaps_after_sintering.pngTaC_aftersintering.jpg 
  276   Friday, September 24, 2021, 15:40 Luca EgoritiTa LP-SISIn progressFull target release test 1 Friday, September 24, 2021, 15:38
Full target loaded with ~500 non-active
foils plus 4 active foils.  
  
  277   Friday, November 05, 2021, 13:38 Luca EgoritiTa LP-SISIn progressFull target release test 2 Friday, November 05, 2021, 13:23
Full target loaded with ~500
 Ta-ReleaseTest-2_low-current.JPG 
  278   Wednesday, November 24, 2021, 10:38 Luca EgoritiTa  In progressIPF release testsWednesday, November 24, 2021, 10:38
A first, short "FullTa1"
target was loaded into the evap1. It consists
  
  20   Wednesday, May 11, 2011, 16:23 John WongSiC38481-8HP-FEBIADProblems Organics burnoff & Sintering Wed May 11 16:20:21 2011:  The HP-FEBIAD
(w.o#38481-8) was filled with SiC (8.5mm,
555 discs).  The target is wrapped with
 9x 
  22   Wednesday, May 18, 2011, 13:13 John WongSiC38295-8HP-FEBIADProblemsOrganics burnoff & Sintering Wed May 18 13:12:24 2011:  Target
is wrapped with 3 Ta-heat shields and is
installed in the evaporator which is being
 6x 
  38   Tuesday, September 13, 2011, 16:53 John WongSiC38295-9HP-FEBIADDoneReady Tuesday, September 13, 2011, 16:51
Target is wrapped with 3-Ta heat
shields. 
 9x 
  47   Tuesday, May 08, 2012, 07:42 John WongSiC38817-3HP-SISDoneSintering SiCTuesday, May 08, 2012, 07:32
Target oven is filled with 240 discs
of SiC/C, and wrapped with 3 Ta-foils.
 TGHT_0_270A.pngSiC#27_0-820A.JPG 
  4   Monday, March 28, 2011, 12:29 John WongEmpty38481-8HP-FEBIADDoneFins diffusion bonding March 28, 2011
12:28:  Target oven is wrapped
with 3 Ta-heat shields.  Pumping down
 grab.Kxr912.pnggrab.L10194.png 
  7   Tuesday, April 05, 2011, 10:37 John WongEmpty38481-6HP-FEBIADDoneFins diffusion bonding Tue Apr  5 10:36:53 2011:  Target
oven is wrapped with 3 Ta-heat shields. 
The evaporator is in the process of pumping
 pumping_down.jpgheatingup.jpgcooling_down.jpg 
  8   Wednesday, April 06, 2011, 17:07 John WongEmpty37978-1HP-FEBIADDoneFins diffusion bonding Wed Apr  6 17:06:56 2011: Target oven is
wrapped with 3 Ta-heat shields.  Pumping
down evaporator in progress.
 pumping_down.jpgAutoheating_parameter_setup.jpgcooling_down.jpg 
  9   Friday, April 08, 2011, 14:55 John WongEmpty38295-8HP-FEBIADDoneFins diffusion bonding Fri Apr  8 14:51:37 2011:  Target
is wrapped with 3 Ta-heat shields. 
The evaporator has been pumped down for over
 pumping_down.jpgAutoheating_parameter_setup.jpgcooling_down.jpg 
  10   Monday, April 11, 2011, 10:22 John WongEmpty38295-9HP-FEBIADDoneFins diffusion bonding Mon Apr 11 10:21:56 2011: Target is wrapped
with 3 Ta-heat shields.  Evaporator
is pumping down. 
 pumping_down.jpgAutoheating_parameter_setup.jpggrab.A29589.png 
ELOG V2.9.2-2455