|  | 53 | Wed Jul  8 17:47:26 2009 | Damien Gallop | Routine | General | 18O4+ emittance scans | First up is a check scan of 18O4+. There is a definite vertical offset compared to
 earlier today. Otherwise, it correlates well
 |       | 
|  | 52 | Wed Jul  8 16:12:51 2009 | Damien Gallop | Routine | General | Mass scan in progress | A mass scan from A/q of zero to 25 is in progress. Data file (large): masscorr_mcis_090708.txt.
 The source is optimized for 18O4+. Fishing
 |     | 
|  | 51 | Wed Jul  8 11:52:54 2009 | Damien Gallop | Routine | General | Supernanogan development run plan for the remainder of this set | * 18On+ emittance scans at present ion source settings: complete today.
 * 18On+ frequency measurements: Thursday.
 |  | 
|  | 50 | Wed Jul  8 10:57:46 2009 | Damien Gallop | Routine | General | 18O4+ emittance scans | Tune saved as 090708_1200.snapmcisfc6. I settled on the 15.486GHz optimal frequency,
 and tweaked that for effect. Then I ran a
 | 10x   | 
|  | 49 | Wed Jul  8 09:34:58 2009 | Damien Gallop | Routine | General | 18O4+ frequency optimization | Starting frequency: 15.7864GHz => 870pA on FC6  Step size: 1MHz. Selected peaks
 shown. There were many smaller resonances
 |  | 
|  | 48 | Wed Jul  8 09:22:07 2009 | Damien Gallop | Routine | General | 18O4+ beam growth overnight | After accessing the OLIS cage and opening the 18O source gas valve, I restarted the
 Supernanogan source last evening around 18:00
 |   | 
|  | 47 | Tue Jul  7 17:47:14 2009 | Damien Gallop | Routine | General | 18On+ beam & emittance | As noted earlier, we have 17O and 18O source gas attached to the Supernanogan source chamber.
 Both are valved off presently. The source
 |  | 
|  | 46 | Tue Jul  7 15:43:19 2009 | Damien Gallop | Routine | General | ISIS emittance rig tests this morning | Keerthi and I were front and centre doing ISIS emittance rig testing this morning.
 He ran it, and I tried to find ways to run
 |    | 
|  | 45 | Mon Jul  6 17:34:24 2009 | Damien Gallop | Routine | General | 18O background studies | Well... my browser blew away just before I submitted version one of this entry. Let's
 try again.
 | 6x   | 
|  | 44 | Mon Jul  6 10:57:08 2009 | Damien Gallop | Routine | General | Beam stability versus temperature over weekend | We had 16O3+ on FC6 on Friday. An IOSIOC reboot occurred mid-afternoon Friday unfortunately.
 Operators restored beam at about 06:00 on
 |   | 
|  | 43 | Fri Jul  3 10:29:15 2009 | Damien Gallop | Routine | General | RF frequency scans versus each charge state of 16O cont'd. | 16O2+ beam on FC6 = 10nA as before. Move to 16O3+ A/q = 5.33...
 A frequency scan between 13 &
 |      | 
|  | 42 | Fri Jul  3 10:03:11 2009 | Damien Gallop | Routine | General | Overnight beam stability on FC3 | Here are some pics and data from total MCIS beam on FC3 overnight. A bit inconclusive,
 but there may be a temperature correlation.
 |      | 
|  | 41 | Thu Jul  2 16:55:04 2009 | Damien Gallop | Routine | General | RF frequency scans versus each charge state of 16O | Let's take a look at varying frequency versus beam current for 16O2+. Starting RF
 values shown below. FC6 = 1.09enA.
 | 7x   | 
|  | 40 | Thu Jul  2 11:58:18 2009 | Damien Gallop | Routine | General | Supernanogan development in progress | Happy Canada Day! I noticed a long-term trend in beam
 intensity. I have every reason to believe
 |     | 
|  | 39 | Tue Jun 30 17:39:13 2009 | Damien Gallop | Routine | General | Compare 16O2+ beam from start of run to today | There seemed to be some small change to the beam over the week of TACTIC running.
 I would like to poke around a bit. The emittance
 | 6x   | 
|  | 38 | Tue Jun 30 17:16:25 2009 | Damien Gallop | Routine | General | 16O2+ emittance scans with slits open | First, with upstream slits opened, then with both open. Original slit setting was
 1mm. Finally, restore slits to 1mm and see
 | 6x   | 
|  | 37 | Tue Jun 30 10:56:26 2009 | Damien Gallop | Routine | General | 16O2+ emittance scans | The first emittance scan sort of got interrupted; it auto-restarted just before the previous
 scan had finished. I thought the resulting
 | 6x   | 
|  | 36 | Tue Jun 30 10:30:17 2009 | Damien Gallop | Routine | General | Initial development setup | Setup teething pains... The Start button on the emittance panel worked this time.
 But ICR called, requesting a few minutes
 |  | 
|  | 35 | Tue Jun 30 09:33:00 2009 | Damien Gallop | Routine | General | Supernanogan Development begins today for two weeks | Supernanogan development starts today. The TACTIC run, which ended around 08:30
 today, appears to have been a success. TACTIC
 |  | 
|  | 34 | Mon Jun 29 10:35:35 2009 | Damien Gallop | Routine | General | 16O2+ pilot beam to TACTIC in progress | We handed over a 16O2+ beam on Wednesday morning to Sophia for TACTIC setup. On our
 side, everything went well. TACTIC switched
 |     |