  53   Wed Jul 8 17:47:26 2009 Damien GallopRoutineGeneral18O4+ emittance scansFirst up is a check scan of 18O4+. There
is a definite vertical offset compared to
earlier today. Otherwise, it correlates well
 grab.Jj2874.pnggrab.fz2878.pnggrab.ND2931.pnggrab.pH2935.pnggrab.oY2939.png 
  52   Wed Jul 8 16:12:51 2009 Damien GallopRoutineGeneralMass scan in progressA mass scan from A/q of zero to 25 is in
progress. Data file (large): masscorr_mcis_090708.txt.
The source is optimized for 18O4+. Fishing
 grab.rh2790.pngPicture_16.pngPicture_17.png 
  51   Wed Jul 8 11:52:54 2009 Damien GallopRoutineGeneralSupernanogan development run plan for the remainder of this set* 18On+ emittance scans at present ion
source settings: complete today.
* 18On+ frequency measurements: Thursday.
  
  50   Wed Jul 8 10:57:46 2009 Damien GallopRoutineGeneral18O4+ emittance scansTune saved as 090708_1200.snapmcisfc6.
I settled on the 15.486GHz optimal frequency,
and tweaked that for effect. Then I ran a
 10x 
  49   Wed Jul 8 09:34:58 2009 Damien GallopRoutineGeneral18O4+ frequency optimizationStarting frequency: 15.7864GHz => 870pA
on FC6  Step size: 1MHz. Selected peaks
shown. There were many smaller resonances
  
  48   Wed Jul 8 09:22:07 2009 Damien GallopRoutineGeneral18O4+ beam growth overnightAfter accessing the OLIS cage and opening
the 18O source gas valve, I restarted the
Supernanogan source last evening around 18:00
 grab.hD1461.png 
  47   Tue Jul 7 17:47:14 2009 Damien GallopRoutineGeneral18On+ beam & emittanceAs noted earlier, we have 17O and 18O source
gas attached to the Supernanogan source chamber.
Both are valved off presently. The source
  
  46   Tue Jul 7 15:43:19 2009 Damien GallopRoutineGeneralISIS emittance rig tests this morningKeerthi and I were front and centre doing
ISIS emittance rig testing this morning.
He ran it, and I tried to find ways to run
 Picture_11.pngPicture_12.png 
  45   Mon Jul 6 17:34:24 2009 Damien GallopRoutineGeneral18O background studiesWell... my browser blew away just before
I submitted version one of this entry. Let's
try again.
 6x 
  44   Mon Jul 6 10:57:08 2009 Damien GallopRoutineGeneralBeam stability versus temperature over weekendWe had 16O3+ on FC6 on Friday. An IOSIOC
reboot occurred mid-afternoon Friday unfortunately.
Operators restored beam at about 06:00 on
 Picture_4.png 
  43   Fri Jul 3 10:29:15 2009 Damien GallopRoutineGeneralRF frequency scans versus each charge state of 16O cont'd.16O2+ beam on FC6 = 10nA as before. Move
to 16O3+ A/q = 5.33...
A frequency scan between 13 &
 grab.Cr7150.pnggrab.yi7257.pnggrab.vt7264.pnggrab.vP7271.png 
  42   Fri Jul 3 10:03:11 2009 Damien GallopRoutineGeneralOvernight beam stability on FC3Here are some pics and data from total
MCIS beam on FC3 overnight. A bit inconclusive,
but there may be a temperature correlation.
 grab.lB3687.pnggrab.w13197.pngmcis_fc3_090703.datiosfc3_fc6_halltemp.txt 
  41   Thu Jul 2 16:55:04 2009 Damien GallopRoutineGeneralRF frequency scans versus each charge state of 16OLet's take a look at varying frequency
versus beam current for 16O2+. Starting RF
values shown below. FC6 = 1.09enA.
 7x 
  40   Thu Jul 2 11:58:18 2009 Damien GallopRoutineGeneralSupernanogan development in progressHappy Canada Day!
I noticed a long-term trend in beam
intensity. I have every reason to believe
 Picture_29.pnggrab.x14914.pnggrab.C15389.png 
  39   Tue Jun 30 17:39:13 2009 Damien GallopRoutineGeneralCompare 16O2+ beam from start of run to todayThere seemed to be some small change to
the beam over the week of TACTIC running.
I would like to poke around a bit. The emittance
 6x 
  38   Tue Jun 30 17:16:25 2009 Damien GallopRoutineGeneral16O2+ emittance scans with slits openFirst, with upstream slits opened, then
with both open. Original slit setting was
1mm. Finally, restore slits to 1mm and see
 6x 
  37   Tue Jun 30 10:56:26 2009 Damien GallopRoutineGeneral16O2+ emittance scansThe first emittance scan sort of got interrupted;
it auto-restarted just before the previous
scan had finished. I thought the resulting
 6x 
  36   Tue Jun 30 10:30:17 2009 Damien GallopRoutineGeneralInitial development setupSetup teething pains... The Start button
on the emittance panel worked this time.
But ICR called, requesting a few minutes
  
  35   Tue Jun 30 09:33:00 2009 Damien GallopRoutineGeneralSupernanogan Development begins today for two weeksSupernanogan development starts today.
The TACTIC run, which ended around 08:30
today, appears to have been a success. TACTIC
  
  34   Mon Jun 29 10:35:35 2009 Damien GallopRoutineGeneral16O2+ pilot beam to TACTIC in progressWe handed over a 16O2+ beam on Wednesday
morning to Sophia for TACTIC setup. On our
side, everything went well. TACTIC switched
 Picture_23_09-22-33.pngPicture_23.pngPicture_24.png 