OLIS Logbook General
  General, Page 21 of 26  Not logged in ELOG logo
ID Datedown Author Type Category Subject Text Attachments
  113   Mon Aug 3 08:39:31 2009 Damien Gallop  MWS 21Ne -> 25Mg switchoverConveniently scheduled for BC Day, we are
preparing to switch over the MWS to sputter
operation with MG source material. Operations
 grab.f18355.pnggrab.n18345.png 
  112   Mon Jul 27 14:39:22 2009 Damien Gallop  21Ne5+ to TUDA-II21Ne has been available from the MWS since
mid-week. Here is roughly how last week unfolded
to now:
  
  111   Wed Jul 22 14:31:28 2009 Damien Gallop  21Ne setup to TUDA-II is underwayLast night Keerthi resolved the sparking
issue in MWS and started the source while
I was present. There was a frozen interlock
 Picture_27.pngPicture_24.png 
  110   Wed Jul 22 01:33:29 2009 Damien Gallop  MWS initial startup summaryVacuum came down to ~7e-7 Torr. On startup,
bias sparked over somewhere. Vacuum leak
was caused. Later we found that HV had sparked
  
  109   Tue Jul 21 17:11:33 2009 Damien Gallop  MWS preparations for 21Ne operationWith the MCIS cart removed, Geoff hooked
up the leak detector to the MWS source gas
line. He did a couple of hours of leak checking
 Picture_23.png 
  108   Mon Jul 20 17:28:01 2009 Damien Gallop  MCIS cart removed from cage and parkedWe discussed whether or not to leave the
Supernanogan in the OLIS Faraday cage, and
decided no, because the up-coming runs will
  
  107   Mon Jul 20 09:25:35 2009 Damien Gallop  18O4+ run to TIGRESS completeThe 18O4+ run at about 5MeV/u ended this
morning with reasonable success, I'm informed,
despite MCIS vacuum trips, SC cryo trips
 grab.rt5424.pnggrab.kH5418.pngPicture_25.pngPicture_24.pngPicture_23.png 
  106   Fri Jul 17 11:10:21 2009 Damien Gallop  Supernanogan development doneBeam switched back to 18O4+ by 11:00 as
agreed. Some glitches. Here are snapshots
of how it looked at handover time.
 6x 
  105   Fri Jul 17 10:46:06 2009 Damien Gallop  16O6+ recheckA/q = 2.666 Field = 767.1G FC6 = 3enA  grab.C25591.pnggrab.q25595.pnggrab.Q25796.pnggrab.w25831.pnggrab.c25693.png 
  104   Fri Jul 17 10:32:42 2009 Damien Gallop  16O8+ recheckA/q = 2 Field = 667.3 FC6 = ~10enA  grab.X25481.png 
  103   Fri Jul 17 10:30:27 2009 Damien Gallop  16O7+ recheckA/q = 2.2857 Field = 710.5G FC6 = 100pA   
  102   Fri Jul 17 10:28:09 2009 Damien Gallop  18O7+ recheckA/q = 2.571 Field = 753.5 FC6 = 50epA   
  101   Fri Jul 17 10:03:07 2009 Damien Gallop  18O6+ recheckA/q = 3 Field = 813.9G FC6 = 2.2enA
I tweaked the adjustment of the displayed
A/q calibration to fit this one.
 grab.a25266.pnggrab.J25270.pnggrab.C25275.png 
  100   Fri Jul 17 09:47:16 2009 Damien Gallop  18O8+ recheckGo fishing in the range 2.24-2.26, but
no fish in this pond this time. However,
there is a relatively strong beam at 2.3.
  
  99   Fri Jul 17 09:33:09 2009 Damien Gallop  Supernanogan epilogueThere are the last couple of hours of Supernanogan
Development for this set. Our run plan included
17On+ studies. Time will not permit it this
 grab.a24906.pnggrab.Q24916.png 
  98   Thu Jul 16 17:15:50 2009 Damien Gallop  16/18On+ survey summaryHere is a summary of emittances gleaned
from the aforementioned elog entries.
  
  97   Thu Jul 16 17:09:52 2009 Damien Gallop  18O1+ surveyA/q = 18 Field = 1987.1 FC6 = 161nA  grab.b17471.pnggrab.r17475.pnggrab.R17480.png 
  96   Thu Jul 16 17:05:29 2009 Damien Gallop  16O1+ surveyA/q = 16 Field = 1873.4G FC6 = 204enA  grab.o17385.pnggrab.G17390.pnggrab.B17394.png 
  95   Thu Jul 16 16:50:41 2009 Damien Gallop  18O2+ surveyA/q = 9 Field = 1405.0G FC6 = 55enA  grab.N17330.pnggrab.Y17335.pnggrab.w17339.png 
  94   Thu Jul 16 16:40:11 2009 Damien Gallop  16O2+ surveyA/q = 8 Field = 1324.8G FC6 = 172enA  grab.u17187.pnggrab.U17191.pnggrab.s17196.png 
ELOG V2.9.2-2455