341
|
Mon Oct 4 09:40:30 2010 |
Damien Gallop | | | OLIS Maintenance and Development completed | The September Mini-Shutdown is now a memory.
The few days available to OLIS were used
for MCIS Development on 197Au. Productive. |
|
342
|
Mon Oct 4 09:46:12 2010 |
Damien Gallop | | | 20Ne1+ at 40.8keV for TIGRESS setup | A 20Ne1+ beam from the MWS was established
on Friday. Line tuning began Friday evening.
A tune to the front of the SC LINAC was in |
|
343
|
Fri Oct 8 09:35:03 2010 |
Damien Gallop | | | 20Ne1+ at 40.8keV for TIGRESS | Beam from MWS quietly sitting on FC6 awaiting
tune checks to TIGRESS. Next experiments
up are 26Alg5+ to TUDA and 24Na5+ to TIGRESS. |
|
344
|
Tue Oct 12 13:25:21 2010 |
Damien Gallop | | | MWS switchover for scheduled 24/26Mg beams | Source switchover in progress on WP#2010-10-12-1.
Magnesium material installed into MWS. Pumpdown |
 |
345
|
Wed Oct 13 16:15:03 2010 |
Damien Gallop | | | MWS switchover for scheduled 24/26Mg beams | Source conditioning most of today, to 59kV.
Striptool attached. Reset to 26Mg tune at
~16:00. |
|
346
|
Fri Oct 15 09:23:03 2010 |
Damien Gallop | | | MWS switchover for scheduled 24/26Mg beams | Source is running nicely. Hand-off
to ICR occurred ~Wednesday night. Setup done
overnight. |
|
347
|
Mon Oct 18 09:22:35 2010 |
Damien Gallop | | | 26Mg6+ for TUDA-II | MWS is producing 26Mg, presently parked.
It was used over the weekend
for TUDA tuning. |
|
348
|
Tue Oct 19 09:20:40 2010 |
Damien Gallop | | | 26Mg6+ for TUDA-II | MWS operating nicely. |
|
349
|
Wed Oct 20 11:30:32 2010 |
Damien Gallop | | | 26Mg6+ for TUDA-II | MWS ran fine overnight. It was shut off
this morning to investigate bias sparking
issue, noted on FR#4894. The two MCIS turbopump |
  |
350
|
Thu Oct 21 11:46:14 2010 |
Damien Gallop | | | 26Mg6+ for TIGRESS | The MWS was restarted yesterday, and a
26Mg beam re-established. ICR set up into
ISAC-II overnight, and tuning to TIGRESS |
|
351
|
Fri Oct 22 09:35:24 2010 |
Damien Gallop | | | 26Mg6+ for TIGRESS | A 26Mg beam was handed over to TIGRESS
last evening. It is 26Mg6+ through ISAC-I
and further stripped to 26Mg10+ by the time |
|
352
|
Mon Oct 25 09:05:15 2010 |
Damien Gallop | | | 26Mg6+ for TIGRESS | Smooth delivery (from OLIS point-of-view)
to TIGRESS over the weekend. An SCB RF amplifier
failed yesterday and was replaced. Tuning |
|
353
|
Tue Oct 26 09:19:39 2010 |
Damien Gallop | | | 26Mg6+ for TIGRESS | The TIGRESS run was scheduled to end at
08:30, but has been extended for 24h. The
ICR reports that they are getting "good |
|
354
|
Wed Oct 27 09:21:59 2010 |
Damien Gallop | | | 26Mg6+ for TIGRESS EOB | The experiment ran overnight, smoothly,
by the looks of it. Beam is on FC6 now, so
they're likely done. EOB studies on Mg beam |
16x |
356
|
Thu Oct 28 17:51:49 2010 |
Damien Gallop | | | MWS switchover for scheduled 85/87Rb beams | A controls issue with IOS:BIAS was found
yesterday. Controls people resolved it today.
MWS source was switched over and prepared |
|
355
|
Thu Oct 28 17:51:49 2010 |
Damien Gallop | | | MWS switchover for scheduled 85/87Rb beams | A controls issue with IOS:BIAS was found
yesterday. Controls people resolved it today.
MWS source was switched over and prepared |
|
357
|
Fri Oct 29 09:41:20 2010 |
Damien Gallop | | | MWS Development | MWS source switchover yesterday was successful.
Leakchecking went well. A small leak on the
intermediate section sealed with a snug on |
6x |
358
|
Mon Nov 1 09:30:15 2010 |
Damien Gallop | | | MWS Development | The source stayed up steadily over the
weekend, with 85Rb on FC6. Not a lot of current,
but pretty good for a first pass. More development |
   |
359
|
Tue Nov 2 09:25:30 2010 |
Damien Gallop | | | MWS Development | 85Rb on FC6 overnight. After restarting
the source yesterday following development,
the beam intensity came back, but it's slightly |
 |
360
|
Wed Nov 3 09:22:38 2010 |
Damien Gallop | | | 85Rb for Polarizer | Yesterday we handed over a 85Rb beam to
ICR. It will be used for a LEBT run using
the Polarizer line. Beam stayed on FC6 overnight. |
 |