M9sol Logbooks
Solenoid
Daily log
Solenoid logbook, Page 8 of 15
New
|
Reply
|
Find
|
Delete
|
Last day
|
Help
|
Config
Full
| Summary |
Threaded
286 Entries
Goto page
Previous
1
,
2
,
3
...
7
, 8,
9
...
13
,
14
,
15
Next
All
ID
Date
Author
Operational Mode
Subject
Text
146
Fri Jul 21 23:36:21 2006
Doug Preddy
Quench Recovery
Final cooldown problems
80K shield is down to <60K Liquid level not
building. Power leads rippling
and warming. T1 inlet 85K with 10%heater
145
Fri Jul 21 17:18:19 2006
Willy Andersson
Quench Recovery
Opened HIC142 fully open
Power leads have flatlined but still building
LHe level.
144
Fri Jul 21 14:08:04 2006
Doug Preddy
Quench Recovery
switch to series mode
Coils temps <10K.Switching to series mode.
143
Fri Jul 21 07:39:37 2006
Doug Preddy
Quench Recovery
Cool down continues
Raised PIC229 to 11Bar. Started to close HIC155.
Cooling rates improve.
142
Thu Jul 20 13:34:26 2006
Willy Andersson
Quench Recovery
cold return mode continues...
Even though cr_c1 and cr_c12 have begun to
tick down, cr_c7 and cr_c6 are
actually ticking up. This is probably a wave
141
Thu Jul 20 13:27:21 2006
Willy Andersson
Quench Recovery
cold return mode continues...
cr_c1 and cr_12 are both at about 45K and
heading slowly down, so the
gamble of going to // cold return worked.
140
Thu Jul 20 13:21:57 2006
Willy Andersson
Quench Recovery
started // warm return flow.
TIC121 was down to 27K
warm return valves were wide open
opened supply valves CV143 and CV146.
139
Thu Jul 20 11:01:09 2006
Willy Andersson
Quench Recovery
Opened up warm return valves CV151 and CV153
Mu2 pressure was just about at trip point
due to trapped volume of helium
warming. So opened up warm returns to bleed
138
Thu Jul 20 08:18:31 2006
Doug Preddy
Quench Recovery
T1 started
Started flow to turbines. Both started. T1
seems a bit slow. HIC110 at 0.85
SI110 = 4100.
137
Thu Jul 20 02:59:06 2006
Doug Preddy
Quench Recovery
T1 still not starting
I will leave the cold box to warm overnight
and try it again in the morning.
136
Thu Jul 20 00:52:13 2006
Doug Preddy
Quench Recovery
T1 frozen
T1 will not spin up. Warming up cold box.
135
Thu Jul 20 00:25:16 2006
Doug Preddy
Quench Recovery
Solenoid quenched @ 11:15
Solenoid Quenched on C1 temp. It went above
5K. Shut off compressor.
Restarting system @ 12:15
134
Thu Jul 6 15:04:17 2006
Doug Preddy
Normal Running
test
test
133
Thu Jul 6 15:00:15 2006
Doug Preddy
Normal Running
test
132
Mon Jul 3 23:01:34 2006
Doug Preddy
Quench Recovery
power lead warming/ripples caused quench
power lead warming/ripples caused quench at
18:45 today. Compressor stayed
on, but flow to solenoid stopped.
131
Fri Jun 30 11:17:57 2006
Doug Preddy
Normal Running
Solenoid recovered
Tuesday night. June 27, 2006, the solenoid
quenched for no apparent
reason. It was restarted Wednesday morning.
130
Fri Jun 30 11:13:00 2006
Doug Preddy
Normal Running
E-log is back up and running
I would have made an entry when it died, but-----
129
Fri Jun 16 08:12:04 2006
Doug Preddy
Normal Running
LI108 indicates high on EPICS screen
LI108 indicates high on EPICS screen (150%)
Controller shows ~64%
128
Wed Jun 14 16:27:01 2006
Willy Andersson
Quench Recovery
Energized solenoid
Powerleads appear stable.
127
Wed Jun 14 10:35:30 2006
Willy Andersson
Quench Recovery
Switched to series cooling.
Had system in //return cooling overnight with
small flow to keep power
leads cool. Switched to series mode about
Goto page
Previous
1
,
2
,
3
...
7
, 8,
9
...
13
,
14
,
15
Next
All
ELOG V2.9.2-2455