Fri Jul 21 17:18:19 2006, Willy Andersson, Quench Recovery, Opened HIC142 fully open
|
| Power leads have flatlined but still building LHe level. |
Fri Jul 21 14:08:04 2006, Doug Preddy, Quench Recovery, switch to series mode
|
| Coils temps <10K.Switching to series mode. |
Fri Jul 21 07:39:37 2006, Doug Preddy, Quench Recovery, Cool down continues
|
| Raised PIC229 to 11Bar. Started to close HIC155. Cooling rates improve. |
Thu Jul 20 13:34:26 2006, Willy Andersson, Quench Recovery, cold return mode continues...
|
Even though cr_c1 and cr_c12 have begun to tick down, cr_c7 and cr_c6 are
actually ticking up. This is probably a wave of warming propagating through
the solenoid. As long as the two inlets are falling in temperature then
|
Thu Jul 20 13:27:21 2006, Willy Andersson, Quench Recovery, cold return mode continues...
|
cr_c1 and cr_12 are both at about 45K and heading slowly down, so the
gamble of going to // cold return worked. Maximum opening of CV155 is
limited by CV204 goes fully closed and suction pressure begins to rise
|
Thu Jul 20 13:21:57 2006, Willy Andersson, Quench Recovery, started // warm return flow.
|
TIC121 was down to 27K
warm return valves were wide open
opened supply valves CV143 and CV146.
|
Thu Jul 20 11:01:09 2006, Willy Andersson, Quench Recovery, Opened up warm return valves CV151 and CV153
|
Mu2 pressure was just about at trip point due to trapped volume of helium
warming. So opened up warm returns to bleed off pressure and prevent it
from rising. |
Thu Jul 20 08:18:31 2006, Doug Preddy, Quench Recovery, T1 started
|
Started flow to turbines. Both started. T1 seems a bit slow. HIC110 at 0.85
SI110 = 4100.
Cool down started. |
Thu Jul 20 02:59:06 2006, Doug Preddy, Quench Recovery, T1 still not starting
|
| I will leave the cold box to warm overnight and try it again in the morning. |
Thu Jul 20 00:52:13 2006, Doug Preddy, Quench Recovery, T1 frozen
|
| T1 will not spin up. Warming up cold box. |
Thu Jul 20 00:25:16 2006, Doug Preddy, Quench Recovery, Solenoid quenched @ 11:15
|
Solenoid Quenched on C1 temp. It went above 5K. Shut off compressor.
Restarting system @ 12:15 |
Thu Jul 6 15:04:17 2006, Doug Preddy, Normal Running, test
|
| test |
Thu Jul 6 15:00:15 2006, Doug Preddy, Normal Running, test
|
| |
Mon Jul 3 23:01:34 2006, Doug Preddy, Quench Recovery, power lead warming/ripples caused quench
|
power lead warming/ripples caused quench at 18:45 today. Compressor stayed
on, but flow to solenoid stopped.
I started flow to solenoid at 22:40. |
Fri Jun 30 11:17:57 2006, Doug Preddy, Normal Running, Solenoid recovered
|
Tuesday night. June 27, 2006, the solenoid quenched for no apparent
reason. It was restarted Wednesday morning. The vacuum in the solenoid
went away (up to 8 Torr). This was found to be a result of a leaking
|
Fri Jun 30 11:13:00 2006, Doug Preddy, Normal Running, E-log is back up and running
|
| I would have made an entry when it died, but----- |
Fri Jun 16 08:12:04 2006, Doug Preddy, Normal Running, LI108 indicates high on EPICS screen
|
| LI108 indicates high on EPICS screen (150%) Controller shows ~64% |
Wed Jun 14 16:27:01 2006, Willy Andersson, Quench Recovery, Energized solenoid
|
| Powerleads appear stable. |
Wed Jun 14 10:35:30 2006, Willy Andersson, Quench Recovery, Switched to series cooling.
|
Had system in //return cooling overnight with small flow to keep power
leads cool. Switched to series mode about 30 minutes ago. Building LHe
level. |
Tue Jun 13 16:04:33 2006, Willy Andersson, Quench Recovery, TIC 121 set to auto mode
|
| |