  26   Wed May 5 23:57:38 2004 Willy AnderssonQuench RecoveryPowerleads warming up again.
Got a page from Don Flemming at about 18:50 wondering why the power
lead temperatures were rising. See attachment may5_04_1800.BMP It looked as
though the monitoring signals flat lined for about 2 hours for some reason.
Anyway the powerlead temps were definitely rising. When I arrived HIC142
was wide open but both power lead flows were down to 65 (on the scale) and
the flowmeter float was vibrating rapidly. LHe heater at 33 %. Buffer 
pressure at 10 psig. LIC108 at 54 %. CV147 at 0.45 (HIC141). CV141 at 0.6
TCI121 in auto mode.

Closed HIC142 then opened again. Powerlead temps dropped. Opened CV147
from 0.45 to 0.35 (HIC141) Played with setting of set point of TIC121 and
HIC141 to try to increase excess liquefaction. Reduced shield heat to about 
16%. Difficult to say what is going on with powerleads. Temps had dropped to
good levels but now gradually rising, but very slowly. Hopefully they peak 
and level off. Energized solenoid. Cycled HIC142 a few times but temps
would not trend downwards. Leaving it overnight. Doug, please check and 
adjust the system as required in the morning.
Attachment 1: may5_04_1800.BMP
  86   Sun Nov 28 10:15:18 2004 Willy AnderssonQuench RecoveryPowerlead quench ?
Got page very early this morning. Couldn't come in til 08:30. System was 
in idle running mode and someone had reset the QRL panel so my guess is 
that the solenoid tripped on powerlead overtemp. HIC142 was not fully open 
and I suspect this is why powerleads heated up. Now in // cold return mode.
Solenoid temps down to 25K and slowly going down. Have HIC142 slightly open 
to keep powerleads cool. Strongly recommend that when running HIC142 should 
be fully open to try to reduce the probability of powerlead warmup.
  171   Thu Oct 26 04:27:31 2006 Willy AnderssonQuench RecoveryPowerlead overtemp
02:30 this morning got page from operations.
Looked at system online, appears that there was a powerlead overtemp
that caused the quench. Compressor still running. After arriving to 
work set system to // warm return mode to cool down transferlines. Lhe 
level starts to boil away. Switch to // cold return mode. Discovered that 
seem to get better cooldown rate by not opening supply valves to solenoid 
fully. // cold return valves are fully open but both CV143 and CV146 are 
only open to 0.55 giving mu1 and mu2 inlet pressures of 2 barA. Getting 
good cool down rates and even building LHe level.

04:25 C1 down to 8K, C12 at 7.5K, C6 at 7.5K, 6KS_M at 10.5K
  77   Thu Nov 4 13:33:49 2004 Doug PreddyNormal RunningPower supply problems
Last night the power supply was ramping up at a very slow rate. This 
morning it was energized,but with no current even though the limit was set 
to 500 amps. Klaus R. found the pot. that set the current limit was bad. 
Repaired it. First try at ramping caused a voltage imbalance and a quench 
I. After a quick recovery, the second try was successfull. Solenoid ramping 
to 500 amps at a good rate.
  16   Mon Apr 26 08:12:30 2004 Doug PreddyQuench RecoveryPower leads flow
Throttled back the LHe in until the power leads started to warm. My goal is 
to flow "warm" gas (hopefully 80K) through the leads to drive any frozen 
impurities out.
  17   Tue Apr 27 09:03:18 2004 Doug PreddyNormal RunningPower leads
Power leads are being monitored with the strip tool graphs. I saw the temps 
go from having a ripple to almost no ripple, but starting to increase in 
temperature. I also noticed that the flow had dropped to 200 mm. I power 
cycled hic142. This resulted in an immediate drop in temperature, an 
increase of flow to 250 mm, and a slight drop in the LHe level. The temps 
seem to be stable, with only a slight ripple.
  73   Mon Oct 25 15:44:15 2004 Doug PreddyNormal RunningPower lead temps starting to ripple
Power lead temps starting to ripple at a 1.5min period. PL flows are 
both>250 mm.
  46   Sun Aug 29 14:39:19 2004 Doug PreddyNormal RunningPower lead ripple
The LHe in and PL-neg temps have been building up a ripple over the last 
few days. Curtis cycled HIC142 Friday evening at about 5:00. I just had 
the Main control room operator (Peter) cycle them again. The ripples died 
right out. 
Originally the ripple was 10.8-11.4K on the LHe-in and 8.9-9.2K on the PL-
Neg. They are now steady at 10.7K and 8.9K.
  207   Thu Jul 5 03:04:50 2007 Doug PreddyNormal RunningPower lead problems
The power leads temps are starting to cycle again. Earlier today M9 
experimentor cycled HIC142 to stablize the oscillations. They started 
again early this morning, so cycled HIC142 again. Oscillations died back, 
but are still present. Will try and warm the power leads later today when 
the experiment's sample is changed.
  44   Wed Aug 25 07:47:05 2004 Doug PreddyNormal RunningPower lead flow
The power lead flows had dropped to 210 mm this morning. I increased HIC142 
from 0.8 to 0.83. The flows are back to <250 mm and the temps are back to 
LHe in-10.8, PL-Pos-11.1, PL-Neg-8.9
  102   Tue Jun 14 18:48:14 2005 ExperimentorNormal RunningPower bump at 18:40
Solenoid tripped on a power bump at 18:40 Tuesday
-- Donald Arseneau
  186   Mon Mar 5 14:59:41 2007 Doug PreddyMaintenancePassword
On the weekend someone used this log to send spam messages. I have 
installed a password for the write privilege. Please contact me at 6399 
for the password.
Doug
  224   Tue Oct 2 13:02:37 2007 Doug PreddyNormal RunningPLC problems
While downloading new code for 2A PLC the M9 and M15 vacuum systems were 
shut off. This is due to the two systems piggybacking onto the 2A PLC.
When M9 Epics came back up there was no controls. Eventually I reset the 
local/remote switch (thumbwheel #100) to button #1 being on. Mike Leross 
added a text and light on the epics vacuum page that says "EPICS works 
only when green". If this light is not green, dial thumbwheel #100 and 
push button #1. Make sure the light comes on and you should have EPICS 
control back.

This caused a glitch in the refrigerator system. It did not trip it off, 
but it would have if the solenoid was energised. The panel showed 
compressor fault and the temps for TI121, and the powerleads all jumped.
This may be a cause for some of our unknown problems.
  221   Tue Sep 25 07:34:04 2007 Doug PreddyStart UpPIC229 to 11 bar
adjusted turbine speeds and HIC104 to maintain their values.
  7   Tue Apr 20 07:33:03 2004 Doug PreddyStart UpPIC229 at 11bar
PIC229 at 11 bar. Changed strip tool to 15 sec increments.
  139   Thu Jul 20 11:01:09 2006 Willy AnderssonQuench RecoveryOpened up warm return valves CV151 and CV153
Mu2 pressure was just about at trip point due to trapped volume of helium 
warming. So opened up warm returns to bleed off pressure and prevent it 
from rising.
  145   Fri Jul 21 17:18:19 2006 Willy AnderssonQuench RecoveryOpened HIC142 fully open
Power leads have flatlined but still building LHe level.
  242   Mon Dec 3 14:59:58 2007 Doug PreddyQuench RecoveryNot really a quench recovery, But...
Not really a quench recovery, but...I wanted to send this out via e-mail. 
The contactor for the compressor building fan failed recently. Randy is 
looking after it, but parts will have to be ordered. The big door should 
stay open until the fan is running again. 
Other than the fan, the rest of the system weathered the weather okay. 
It's up and running until Wednesday morning. After maintenance day, we 
should ramp down the solenoid power supply and leave the refrigerator 
running. We can do some training and maintenance at this time. I would 
also like to keep it cold until blocks can be removed so we can pump out 
the cold box.
  219   Wed Sep 19 20:53:18 2007 Doug PreddyMaintenanceMore diff pump news
Cold box pumped out to ~ 190 mTorr overnight.Leak checked the pump again. 
Still leaks at dip stick.Tried resetting the o-ring on the dip stick. It 
still leaks baddd!!!
Machined the old seal off and installed a smaller o-ring onto dip stick. 
Installed 60 ml of new pump oil into pump. Pumping down again. 
After 4 hours the cold box is down to 160 mTorr.