Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production, Page 5 of 8  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
  ID Date Author Target/No.# Source Station Module Target Oven W.O#down Heat Shield W.O# Status Subject Text Attachments
  87   Monday, October 15, 2018, 07:36 Aaron SchmidtTa#57 ITETM441177-3  Ta#57 Target Description.(Laura Lambert: Evap 2 Elog ID: 404) Tuesday,
April 17, 2018, 10:20
  
  50   Friday, April 17, 2015, 16:00 Laura LambertUCx # 12LP-SISITWTM141177-2 ReadyUCx#12 Target Description Thursday, April 16, 2015, 14:07
See attachment for target description
 UCx_12_target_description.PNG 
  54   Tuesday, July 07, 2015, 13:00 John WongZrC#7LP-SISITWTM241177-2 ReadyZrC#7 (backup1) target descriptionTuesday, July 07, 2015, 12:36 
Total no. discs = 422
Total packed length = 13.2 cm (measured
 ZrC#7_backup.PNGZrC_specification_(backup#1_WO#41177-2).xlsx 
  52   Wednesday, June 03, 2015, 10:55 Laura LambertZrC#7LP-SISITWTM241177-1 ReadyZrC#7 target description  Wednesday, June 03, 2015, 10:53
Total length packed = 12.3cm
See attachment for target description.
 target_production_elog_ZrC#7.JPGZrC#7_final_density.xlsx 
  53   Monday, July 06, 2015, 12:18 John WongZrC#7LP-SISITWTM241177-1 FailedZrC#7 target description

    

       
            
  
  59   Monday, October 26, 2015, 16:33 Laura LambertUCx#14LP-SIS  41077-5 ReadyUCx#14 Target Description Monday, October 26, 2015, 16:23
Attached please find
 Capture.JPG 
  60   Friday, March 04, 2016, 14:57 Laura LambertUCx#15LP-SISITW 41077-1 ReadyUCx#15 Target Description Friday, March 04, 2016, 14:56
Attached please find the UCx#15
 UCx_15_description.jpg 
  63   Wednesday, June 08, 2016, 15:55 Laura LambertUCx#16LP-IG-LIS  40860-2 ReadyUCx#16 Target Description Wednesday, June 08, 2016, 15:52
Attached please find the UCx#16
 Target_Description.JPG 
  55   Friday, July 10, 2015, 11:23 John WongUCx#13LP-IG-LISITETM440860-1 ReadyUCx#13 Target description Friday, July 10, 2015, 11:15
Attached please find the UCx#13 target
description.   
 UCx_13_target_description.PNG 
  48   Thursday, November 06, 2014, 13:35 Laura LambertUCx # 11LP-SISITETM440282-5 ReadyUCx#11 Target Description Thursday, November 06, 2014, 13:29
See attachment for target description

 
 UCx_11_target_description.PNG 
  45   Monday, July 28, 2014, 15:57 John WongZrC#6LP-SISITWTM140282-3 SpentZrC target description  Monday, July 28, 2014, 15:52
See attachment#1 for ZrC target description. 
Target is currently undergoing the
 ZrC#6.JPG 
  43   Tuesday, July 15, 2014, 10:54 Laura LambertTa # 43LP-SISITWTM140282-2 ReadyTa # 43 Target Description Tuesday, July 15, 2014, 9:45
Ta#42 LP-SIS target description:
  
  39   Monday, March 17, 2014, 16:15 John WongTa#42LP-SISITWTM440282-139956-1SpentTa#42 Target description Monday, March 17, 2014, 16:14
Ta#42 LP-SIS target description:
Total Ta foils = 400
  
  67   Friday, September 02, 2016, 14:45 John WongSiC#34LP-IG-LIS  39814-V2-1 ReadySiC#34 Target Description  Friday, September 02, 2016, 14:43
See attachment for target description 

 
 SiC34_target_description.JPG 
  38   Wednesday, November 27, 2013, 17:56 John WongUCx#8LP-IG-LISITETM439814-IV SpentUCx#8 target description Wednesday, November 27, 2013, 17:49
UCx#8 target description - see attachment#1

 
 UCx_8_specification.PNG 
  68   Friday, October 07, 2016, 16:27 John WongSiC#35HP-FEBIAD  39530-9 ReadySiC35 Target description Friday, October 07, 2016, 16:28
See attachment for the target description

 
 SiC35_target_description.JPG 
  36   Friday, August 30, 2013, 14:45 John WongNiO#2HP-FEBIAD  39530-639069-4SpentNiO target descriptionFriday, August 30, 2013, 14:38 
NiO/Ni#2                                            
Average
  
  57   Thursday, September 24, 2015, 13:42 Laura LambertSiC#32HP-FEBIAD  39530-5 ReadySiC#32 target description Thursday, September 24, 2015, 11:46
See attachment for target description.

 
 elog_snapshot.JPG 
  80   Wednesday, September 27, 2017, 09:14 Laura LambertSiC#37HP-FEBIADITETM439530-10 ReadySiC#37 target description Wednesday, September 27, 2017, 09:13
See attachment for target description.

 
 Target_Description.JPG 
  42   Friday, June 06, 2014, 14:09 John WongUCx#9LP-SIS  39165-9 ReadyUCx#9 - Target description  Friday, June 06, 2014, 14:08
See attachment for the target description

 
 UCx#9_target_description_1.JPG 
ELOG V2.9.2-2455