Wednesday, November 27, 2024, 18:38 |
Albert Kong | Hot Cell 1 | Standard Operation | APTW Front End Electrical Cable Replacement Testing |
November 27, 2024
Testing completed:
- Removal and re-insertion of 2x multi-pin coupling cable for HTV (see pictures, left most and right most, middle had no wire at the time).
- Tested using 'wire' method to pull cable once removed back through the original path.
- Test without rotating table, on cart, some obstruction that does not reflect reality in operation, rotated cart by hand, will require rotation during operation.
Observations/notes:
- Right connector has wires come across and may interfere with the middle connector, will require removal of multiple connectors to exchange one depending on configuration.
- Locating pins on high voltage multi-pin connector needs to be short for voltage bias reasons.
- Right-most black multi-pin cylindrical connector has higher risk of machined block end catching when fishing from the HTV side.
Recommendations:
- May be a good idea to add a holder connector to go into the multi-pins and give the manipulators a better grip for handling. Directly grabbing on the cylinder of the multi-pin connector is ok though.
- Some strain relief at the machined connector blocs (service tray side) will help prevent damage during wire replacement/routing.
- Possibly re-route some of the electrical connectors to the back side of the HTV column for easier access and shorter length.
- Will need chart mapping where the cables go and indexing different connections for future hot cell work (will be updated on SW model).
- Locking pins on multi-pin connectors can be removed and replaced manually with the manipulator.
- Adding a 'slippy' sheath onto the replacement cable for routing and to prevent catching would be a good idea in the future.
-----------------------------------------------------------------------
Dec 02, 2024
Testing completed:
- Removal and re-insertion of 1x ceramic-ended wires specifically the one obstructed by the gas line on the right side of the HTV connection array as viewed from the hot cell window.
- Removal and re-insertion of main multi-pin connector cable bundle from the HVFT connector array on the service tray.
- Removal and re-insertion of the gas line obstructing the right-side ceramic electrical connectors << very difficult/impossible to do (recommend modifications + tooling).
Observations/notes:
- Electrical wires/connectors generally straightforward to exchange.
- Plastic/ceramic components on connectors are easy to damage during exchange operation.
- Most connectors require the metal/cylindrical bits to be 'grabbed' by the manipulators if no custom tool is used
- Rectangular multi-pin connector bracket if single is difficult to return to slot since not supported on both sides
- Need documentation/reference material to make sure connectors get returned to where they need to be
- Screws on connector are deep into the FE assembly, creates viewing difficulty
- Cameras hard to use for these screws because of beam dump being highly active when FE is in operation
- Ceramic (mass marker) connectors fine to grab on the conductor part
- When trying to re-align the ceramic bodies to line up the screw holes, found that it was really easy to damage/break the ceramics, avoid using hard tooling/manipulators on the ceramic parts
- Plastic components on multi-pin rectangular brackets got damaged after handling with manipulators
- Full sized pin detent tool not compatible with smaller pins, should make smaller sized pin detent tool, smallest clearance found on HVFT side of multi-pin connector bundle
- Routing HVFT side of multi-pin bundle through wires poses risk of damaging exposed pins
Recommendations:
- Should buy longer bits/ends for torque control tool to get better view angles on screws.
- Maybe captive screw for the gas is a good idea to prevent the screw from dropping.
- Torque tool should be set properly (torque and rotation rate) before performing screw exchanges involving the HTV connectors on the front end
- Return of the gas line (on bracket) to its location on the FE is difficult, suggested modifications include:
- Changing orientation of cutout on bracket to let stainless bent/welded tube to be returned separate from the bracket.
- Changing screws for the stainless part on the gas line to be standard size (M6) for hot cell exchange operations.
- Changing the unused screw hole on the FE to be pinned and allow for better alignment of the bracket onto the FE
- Removing burr on sheet metal part on hose/wire opening at the bottom to prevent the braided hose from catching.
- Should make a rotator tool (3D printed) to help adjust the ceramic end of the mass marker connector and have the screw hole and thread aligned
- Maybe plastic covers for water/gas connectors to prevent scratching of outer surface
- Make smaller pin detent tool or settle for old tool already made
- Possibly design cover to protect exposed pins on multi-pin bundle during replacement
-----------------------------------------------------------------------
Dec 12, 2024:
Testing completed:
- Tested removal and return of the gas line obstructing some ceramic electrical cables on the right side of the HTV connector array on the front end, now with 6mm pin (McMaster 97493A162) threaded into the previously unused hole to help guide the previously unused hole to help guide the bracket.
- NOTE (20 Feb, 2025): further testing for servicing these lines is documented in a later ELOG (#78)
Observations/notes:
- Chad Fisher commented that even without the pin it should be possible to complete the removal and return operation if a 3D printed (soft )tool is made to grab onto the tubes and guide it with the bracket into the alignment hole/slot.
- Old recommendations still stand though + maybe make the pin longer/custom with more lead in.
Recommendations:
- Remove the retaining tab at the bottom to allow the hose to be positioned more freely.
- De-burr the sheet metal part to prevent catching on the braided hose.
|
Attachment 1: IMG_0523.JPEG
|
|
Attachment 2: IMG_0525.JPEG
|
|
Attachment 3: IMG_0526.JPEG
|
|
Attachment 4: IMG_0541.JPEG
|
|
Attachment 5: IMG_0544.JPEG
|
|
Attachment 6: IMG_0555.JPEG
|
|
Attachment 7: IMG_0599.JPEG
|
|
Attachment 8: IMG_0605.JPEG
|
|
Attachment 9: IMG_0659.JPEG
|
|
Attachment 10: IMG_0665.JPEG
|
|
Attachment 11: IMG_0674.JPEG
|
|
Attachment 12: IMG_0685.JPEG
|
|
Attachment 13: IMG_0688.JPEG
|
|
Attachment 14: IMG_0731.JPEG
|
|
Attachment 15: IMG_0701.JPEG
|
|
Attachment 16: IMG_0703.JPEG
|
|
Attachment 17: IMG_0728.JPEG
|
|
Attachment 18: IMG_0745.JPEG
|
|
Attachment 19: IMG_0746.JPEG
|
|
|
71
|
Tuesday, November 19, 2024, 15:38 |
Albert Kong | Hot Cell 1 | Standard Operation | APTW Front End Moved into Hot Cell |
The APTW front end was moved into the hot cell, on the lift table, following procedures outlined in Document-244862.
The mock-up frame was transferred from the east turntable to the west turntable above the front end. The east turntable is covered with the aluminum plate. During covering we accidentally broke the o-ring for the turntable plate flange. The new o-ring seal should be made ~1" longer in circumference to avoid difficulties with seating in the o-ring groove.
When we attempted to move the front-end with the manipulator, we noticed that the front end tended to carry on sliding down the slope of the hot cell (see TRI-DN-23-20 / Document-238536). The manipulators were subsequently unable to arrest the front end, likely because they cannot apply a load towards the CG of the front end. Therefore, for heavy-duty jigs in the hot cell it is advisable to avoid using wheels/rollers that allow the heavy assemblies to move freely on the lift table.
--------------------------------------------------------------------------------
UPDATE Nov 21, 2024
- FE attachment related tests completed:
- replacement of shim plates
- mock-up alignment of FE with shield plug (adjustment made in person, hot cell operator instruct and give direction with remote camera views
- Difficulties encountered:
- keeping track of which hole/screws are seen by the cameras during alignment was difficult for the operator
- shim plate awkward to handle if not familiar
- incompatible coupling screw and nut threads (M24 course vs fine threads) prevent completion of coupling and uncoupling tests
- 'loose' service tray requires separate alignment check when raising the FE with the lift table
- Lessons learned:
- shim plate replacement easier if FE is semi-attached (screw lifts FE, leaving small gap for shim plate to be inserted)
- need a cover plate to prevent dropping shim plate and associated screws
- rotation clearance of FE checked, will clear
- need to also check service tray alignment when raising
- magnetic cameras would be beneficial for this operation
- Follow up items:
- crane-based positioning of FE for replacement to be tested after concrete pours/hand-testing/when APTW is exchanged for AETE.
- future design of protective covering when performing shim plate removal
- optionally implement magnetic camera array to check hole alignment by looking directly at the holes
At end of shift, mock up and FE was separated, markings made on floor to specify where FE needs to be to couple.
--------------------------------------------------------------------------------
UPDATE Nov 25, 2024
Replacement nuts arrived (M24x3) for the coupling screws. Tests were completed to try and couple/uncouple the front end to the cart/mock up.
- For taking the FE on/off the cart the cart should be able to rotate with the FE so that we can secure the coupling screws.
- For dropping the FE off from the shield plug, we should make use of the alignment features (cup and cones), once screws are undone and the FE rests on the cones on the cart, it should be secured.
- If markings on floor is made to assist with alignment, we need to do two sets; one for unloaded cart, one for loaded cart, this is because the lift table will tilt differently when there is a load.
- The threads on the coupling screws are fine threaded in the real case, there is a slight concern with cross-threading when turning them onto the nuts remotely (from above).
- Existing camera views sufficient to check for clearance between coupling plates and FE structures.
- To allow the FE to guide freely into the alignment features (cup/cone), it may be a good idea to still use the air skates, but supplement it with structural 'stopping' features to keep it from rolling off the table.
--------------------------------------------------------------------------------
UPDATE Nov 26, 2024
We returned the front-end to the cart to allow the shield-plug mock up to be rotated by the target hall crane (turntable still not functioning as of this date).
During this operation we noticed that the front end did not fully return to the alignment cones on the cart (see images), somehow the contact pad screws made contact first, and so the two-faced alignment cone did not come into contact.
For the real support frame we should use a minimal number of contact points. Also,more clearance at the coupling screws between the cart to the front end should be added.
--------------------------------------------------------------------------------
UPDATE Nov 27, 2024
We rotated the mock-up frame manually to have the HTV side face the hot cell window. During which the o-ring fell and we decided to cut it for convenience, this should be replaced with an equivalent o-ring but made ~1" longer in circumference.
--------------------------------------------------------------------------------
UPDATE Nov 28, 2024
Today we attempted to re-couple the front end to the mock up frame in the orientation where the HTV faces the hot cell window. The misalignment between the FE on the cart to the mock-up frame is worse in this orientation than in the previous (90 CCW facing down). There was approximately a 1" gap difference between the opposite ended screws. Factors contributing to the misalignment include uneven seating of the FE onto the bosch frame and uneven 'brake' engagement on the bosch frame wheels. During the attachment process the the screws had to be tightened very unevenly, with the HTV side being tightened far more than the extraction electrode side.
Additionally, the service tray shifted significantly from handling in the previous days and it was difficult to align the locating pins/cylinders. This further complicated the coupling process, in the future the service tray attachment should be made a separate operation to the process of coupling the FE to the shield plug.
Under these conditions, during tightening, the inner screw at the HTV-side somehow jammed against the nut and the nut conversely jammed into the bracket. Subsequently, that screw could not be tightened further and required great difficulty to be removed, even after removing the bracket. In the aftermath, the nut bracket became forced apart (see picture) and the threads on the screw deformed beyond use. This is a critical failure mode for this coupling system. Note that the screw was hand started onto the nuts on the brackets prior to fully tightening the screws.
We believe the factors contributing to this failure include:
- bracket gap being too large and allows the nut to wedge itself during tightening,
- screw threads not being hardened/of proper grade,
- tightening the screws too unevenly and sharply (too large turns per-screw when bringing the FE up, 1/2-1 turn) / allowing some screws being slack,
- high misalignment (pitch and roll) between the FE plate and the mock-up frame,
- the brackets not being able to accommodate the observed misalignment,
- hole for screw is ~short and creates possibility for jamming when there is misalignment (pitch and roll),
- aligning the service tray locating features while aligning the screw holes for the FE coupling was difficult,
- possibly the extra lead in (chamfer) on the coupling screws is excessive and a non-standard design, which may cause problems starting the nut, likely a standard chamfer on the end of a standard screw would be sufficient for this operation
In the real operation, the long length of the screw will help prevent this failure from happening but some things to keep in mind/improve on would be:
- bracket re-design to use standard wrench/nut gaps to avoid nut jamming
- use hardened threads
- try to see if no-lead in/chamfer/using standard screw profiles is sufficient
- re-design the coupling system to not require a nut at the bottom and avoid cross-threading/thread jamming in the hot cell (move threads and nuts all above the FE assembly)
- extra: the screw should not be fine threaded in the real case to avoid cross threading
- minimize misalignment when trying to couple in the future (rotate turntable to minimum misalignment orientation)
- tighten the screws more incrementally to have them go together evenly, don't allow screws to be fully slack if possible to prevent jamming
- fully remove the service tray and attach only after the FE is attached
Of the above recommendations we strongly recommend re-designing the nut bracket - even when coupling was smooth (without misalignment) the nuts made a visible dent onto the bracket at the highest point (see image). A smaller gap (standard wrench gap) would prevent such a mark from forming.
We replaced the deformed screw with a standard (off the shelf) one to keep the FE secure to the mock-up.
We also noted after completing coupling that the extraction electrode, farthest out screw had damaged threads (see image).
It is recommended to perform repeated coupling/decoupling operations in the hot cell after some process/design changes are made/implemented to work out any possible failure modes with this operation.
|
Attachment 1: 4dab0178-cbf6-4af0-b663-67fd0d54c199.jpg
|
|
Attachment 2: 568feb0c-d1a7-46e8-8686-e3e7bd5d1dc1.jpg
|
|
Attachment 3: 3578f845-4f0c-4776-8fde-7c859ec40bbf.jpg
|
|
Attachment 4: IMG_0419.JPEG
|
|
Attachment 5: IMG_0466.JPEG
|
|
Attachment 6: IMG_0468.JPEG
|
|
Attachment 7: IMG_0454.JPEG
|
|
Attachment 8: IMG_0480.JPEG
|
|
Attachment 9: IMG_0487.JPEG
|
|
Attachment 10: IMG_0483.JPEG
|
|
Attachment 11: IMG_0484.JPEG
|
|
Attachment 12: IMG_0511.JPEG
|
|
Attachment 13: IMG_0512.JPEG
|
|
Attachment 14: IMG_0513.JPEG
|
|
Attachment 15: IMG_0522.JPEG
|
|
Attachment 16: 666c4d22-d093-4570-978e-ee23141e362d.jpg
|
|
Attachment 17: bfd8c4e1-f434-47fc-8690-dbd28c9d884c.jpg
|
|
Attachment 18: IMG_0615.JPEG
|
|
Attachment 19: IMG_0619.JPEG
|
|
Attachment 20: IMG_0623.JPEG
|
|
Attachment 21: IMG_0624.JPEG
|
|
Attachment 22: IMG_0628.JPEG
|
|
Attachment 23: IMG_0631.JPEG
|
|
|
70
|
Thursday, October 17, 2024, 11:34 |
Albert Kong | Hot Cell 1 | Development | Tarping completed on hot cell roof |
Two tarps were installed above the hot cell roof to protect against concrete dust while testing in the hot cell.
Zip ties were used to hook the tarp onto tubing brackets on the back wall. |
Attachment 1: 90ab24ac-d55b-43ac-8630-02cd9ca2df85.jpg
|
|
Attachment 2: IMG_0325.JPEG
|
|
Attachment 3: IMG_0326.JPEG
|
|
|
69
|
Thursday, October 10, 2024, 12:22 |
Adam Newsome | Hot Cell 1 | Standard Operation | Safety Walkaround Complete - Hot Cell area |
A safety walkaround was completed for the ARIEL Hot Cell area.
The resulting spreadsheet can be found on DocuShare as Document-242733.
No major deficiencies identified. |
|
68
|
Tuesday, September 10, 2024, 13:03 |
Adam Newsome | Hot Cell 1 | Development | Spacer flange installation |
The spacer flanges were installed on both turntables today.
See photos and information in the following DocuShare Collection: Collection-39816
Important note: the fitment was quite tight due to interference with universal joints and grease nipples. The flanges were still able to be installed with a bit of difficulty. They are not posing any immediate issues, but it is predicted that the adapter flanges will certainly interfere with drive system components. It is necessary to change the design of the adapter flanges to allow for the appropriate clearance. |
|
67
|
Tuesday, September 10, 2024, 12:52 |
Adam Newsome | T-Hall Crane | Standard Operation | Drive not ready faults observed on power-up |
Upon powering on the crane today and attempting to use the main hoist, the following faults were present:
1. Main Hoist East Drum North Motor Drive Fault (700VFD)
2. Main Hoist West Drum South Motor Drive Fault (900VFD)
3. Main Hoist East Drum North Motor Drive Not Ready (700VFD)
Note that the auxiliary hoists functioned as normal.
Upon power cycling the crane to reset, the faults disappeared, and the main hoist functioned normally again. The root cause of the issue is unknown. It is suspected to be related to either prolonged inactivity, improper safety reset sequence, or the battery being removed from the pendant. This issue will be monitored for re-occurrence. |
|
66
|
Wednesday, July 17, 2024, 15:07 |
Adam Newsome | Hot Cell 1 | Standard Operation | Safety Walkaround Complete - B2 Level |
A safety walkaround for July 2024 was completed for the B2 level by A. Newsome. No deficiencies to report.
Results can be found in the master spreadsheet |
|
65
|
Wednesday, April 24, 2024, 09:17 |
Adam Newsome | T-Hall Crane | Repair | Target Hall Crane: VFD DC bus undervoltage fault [root cause: encoder board failure on 900VFD] |
On 2024-04-22 around 3:30 pm it was discovered that the crane's main hoist was in a faulted state. The operator (Adam Newsome) experienced the fault after performing a safety reset and attempting to lower the hoist. There were no visible signs of any issues, mechanically. This fault had not been previously reported by any other crane operators. The crane was previously unused, sitting idle. Note: the auxiliary hoists appeared to function normally.
Fault messages on the HMI indicated:
"135. Main Hoist West Drum North Motor Drive Fault (1000VFD)"
"104. Main Hoist East Drum South Motor Drive Fault (800VFD)"
"103. Main Hoist East Drum North Motor Drive Fault (700VFD)"
"138. Main Hoist West Drum South Motor Drive Not Ready (900VFD)"
"136. Main Hoist West Drum South Motor Drive Fault (900VFD)"
It is clear from this that there is either some sort of common issue seen across all these main hoist VFDs, or one issue with one of them which caused a cascading series of faults.
On 2024-04-23, upon investigation of these faults by going online with the PLC to determine fault logic, it was clear that all faults were indeed present, but there was no obvious indication as to what it was. Inspection of the VFDs in the control panel showed that all of the aforementioned drives displayed a fault code. This was fault code 4 which indicates DC bus undervoltage.
After researching this fault online, it appears this is typically caused by an issue with the input mains supply (480VAC @ 3 phase in this case), or by the drive's input DC filter/buffer circuitry. When measuring the DC bus voltage, it is expected for it to be approximately 1.414 times the AC supply voltage. In this case, 1.414*480 = 678 VDC. The first troubleshooting step was to measure to confirm the DC bus voltage on a known working and not working drive.
The bus voltage was probed on drive 500VFD which, based on lack of fault message, was expected to be functioning properly. With the safety off due to E-stop condition, the voltage was nearly zero. When a safety reset was pressed to enable the drive, the voltage changed to 690 VDC. This is close enough to the expected 678 VDC. The voltage did not change, even when the fault message for the other drives appeared again.
Next, the bus voltage on two known faulted drives, 900VFD and 1000VFD, was probed. In both cases, after the safety reset, the bus voltage started at 690 VDC but then slowly dropped down towards nearly zero (somewhere around 18 V) over a period of 3-5 seconds. It was during this transition when the voltage dropped off that the undervoltage condition became true, which triggered the fault.
As of 2024-04-24, the root cause of this issue is unknown. It will be investigated further and this e-log will be updated when a solution is found.
Update 2024-04-24: the root cause has been identified. The undervoltage fault was just a symptom as a result of the input contactors for these drives switching off, causing the DC bus voltage to drop slowly due to capacitance in the input filtering circuit. The reason for the input contactors switching off is attributed to safety signals dropping out due a fault observed specifically on 900VFD. When looking at the drive itself, a fault with code 4030 was displayed: Enc1 open wire.
This fault implies the encoder may be disconnected. The encoder wiring was checked: OK. The encoder cable was swapped with a unknown working one from an adjacent drive - the issue remained with 900VFD, which suggested the problem is with the drive itself. The encoder board (20-750-DENC-1) was swapped with an adjacent drive and the problem followed the board. The encoder board was then switched with a brand new spare (note: jumpers needed to be set!).
Upon power-cycling the system, the fault did not persist. Therefore, it is suspected that the encoder board had failed (in fact this happened previously with the same drive - see e-log 42). Upon inspection, one of the capacitors on the board appeared to be cracked - this will be investigated further to see if replacing it fixes the problem.
A spare encoder board will be ordered. This issue should be monitored in the future - it seems as if the drive itself is perhaps causing the encoder boards to fail.
Note: upon powering the system on again, another issue was noticed: 500VFD shows "drive not ready" fault. This is not displayed on the HMI though - it was just not possible to reset the safety system and this was only discovered from going online with the PLC. This will be investigated further.
Update 2024-04-26: the 500VFD "drive not ready fault" was investigated. It was determined that the SP+ (safety power +) signal wire was loose, which meant the safety signals to the drive were not getting through, causing it to remain in a "not ready" state. The wiring issue was corrected. Performing a safety reset resulted in successful drive enables across all drives. However, upon attempting to move the crane, even though all safety signals were green and it appeared to be able to move, it did not.
It turned out that there was a crane pendant fault: "Fault 305. Radio Control Receiver in Fault (3700RC)". This is exactly what happened previously in a similar situation (see e-log 55). The steps mentioned in that e-log were followed (power cycle, reconnect antenna/connector). Upon powering back up, everything worked as normal. The crane was tested in local mode - all three hoists up/down (main hoist run to upper limit), all trolley travels in each direction, and bridge travel in each direction.
As of now, everything is operating normally and all issues are considered to be resolved. A spare encoder board has been ordered. |
Attachment 1: DC_bus_voltage.jpeg
|
|
Attachment 2: PXL_20240422_225858594.jpg
|
|
|
64
|
Wednesday, February 14, 2024, 09:02 |
Adam Newsome | T-Hall Crane | Maintenance | Target Hall Crane: Trolley Encoder Homing |
The main trolley's E/W motion was observed to be slowed on 2024-02-13.
Upon investigation, the following faults were present:
- 200. Rotating Hook Velocity Difference between SSI Encoder and Drive Speed Feedback
- 82. Main Hoist Slack Rope
It is suspected that these faults are irrelevant in this situation. Upon inspection of the main trolley status screen, it was evident that both the SLOW EAST and SLOW WEST indicators were on (which matches observations). Clicking one of these status icons showed "Main Trolley Encoder Not Homed 2253ENC".
Logging in as an administrator allowed for homing the encoder.
The trolley was moved all the way East, to the limit, and the encoder was homed at position 0.389m (encoder count = 6886940). Note: the alignment arrows were not used as this would have required gaining access to the crane which was difficult at the time. It is suggested to properly home it in the future.
The E/W motions were fully tested to confirm proper slow down and stopping at the expected positions. The crane appears to be operational as of 2024-02-14.
|
Attachment 1: PXL_20240214_160748765.jpg
|
|
|
63
|
Wednesday, August 02, 2023, 09:13 |
chad fisher | Hot Cell 1 | Repair | Leak Rate Testing |
On August 1, 2023 HC1 was pumped down to -1200 Pa (gauge) and then valved off to test the leak rate after turntables had been sealed with backer rod in the gaps.
The sealing with backer rod allowed the cell to reach the test pressure of 1000 Pa. The cell pressure equalized within 30-40 seconds which is an improvement but still not sufficient to meet the goals we have set.
Next step is to pump down to -500 Pa and use smoke generator and perform thorough investigation to identify any leaks. |
|
62
|
Wednesday, April 26, 2023, 16:06 |
Adam Newsome | T-Hall Crane | Maintenance | Target Hall Crane - Hoist Wire Wrapping |
It was observed recently that the main hoist's wires seemed skewed, and there was occasionally some noise heard when raising and lowering the hook block. It was suspected that this was due to wires having jumped in their tracks at some point. This is typically caused by side loading. It is possible that wire wrap skew occurred during the incident outlined in e-log 46.
Gordon Crane was contacted for a service call. Crane inspector Ali from Gordon Crane was supervised/assisted by Maico Dalla Valle. They lowered the hoist down into the target pit and supported it on saw horses, then let the wires run all the way out. Ali confirmed that there was a wire wrapping issue, and re-seated the wires properly. The crane is now functioning normally. It is recommended to re-apply lubrication as soon as possible.
Note: Ali from Gordon Crane has advised that it is acceptable for some degree of wire skew to occur - they can handle the abrasion if there's a small angle between them. However, wires should not be rubbing across each other at a large angle (ex. more than approx. 10 degrees). |
Attachment 1: 20230131_120303.jpg
|
|
|
61
|
Tuesday, April 25, 2023, 12:28 |
Adam Newsome | T-Hall Crane | Standard Operation | ARIEL Target Hall Crane - Drives Fault |
Today while operating the crane with load, the crane stopped moving. Upon investigating, all safety signals appeared to be OK. Fault messages regarding drive faults for various VFDs were present, which seemed to stem from an ethernet adapter card fault (see attached photo). It is unknown how this occurred, but suspected that it was due to a brief blip in network communications or the external drive power supply control signal. It is worth noting that the diesel generator tests took place today, and there could have been some affect from a power surge because of this.
The crane was power-cycled using the main disconnect, and safety system reset. The faults disappeared. The crane was operational again.
If this issue occurs again, it should be investigated more thoroughly. It would be worth checking if there were any generator tests or other things which could cause some sort of power surge. |
Attachment 1: MicrosoftTeams-image_(10).png
|
|
|
60
|
Tuesday, March 21, 2023, 10:47 |
Adam Newsome | Hot Cell 1 | Repair | Circuit breaker replacement - telemanipulators |
There was an issue with a 20 A circuit breaker used to control motor assist functions for the telemanipulators (specifically, the rightmost CB in the panel for the right (East) manipulator set). This circuit breaker was moved to the panel for the left (West) manipulator set in the rightmost position, and then subsequently replaced with a new one, which is functioning correctly. It is suspected that the former CB which was not working was calibrated towards the low end from the factory, based on discussions with the manufacturer and extensive testing of multiple scenarios. |
|
59
|
Thursday, March 16, 2023, 14:41 |
Adam Newsome | T-Hall Crane | Development | ARIEL Target Hall Crane - Spare Pendant Procured, Tested |
A spare pendant for the overhead crane was procured from COH. The pendant's functionality is the same as the original one's. The pendant was tested today by Adam Newsome - all functions behave as expected.
Important - to change to the spare pendant in the case of failure of the original one, insert a battery into it, and transfer over the small black transmitter card shown in the attached picture. The pendant will not pair with the receiver without this card. There is nothing else that needs to be set up for it to work.
The spare pendant is kept in a labeled box on top of the electrical cabinets located in the crane control room (L1 floor). |
Attachment 1: PXL_20230316_204047237.jpg
|
|
|
58
|
Friday, January 20, 2023, 14:48 |
Adam Newsome | T-Hall Crane | Standard Operation | Pendant/Receiver Communication Issue (Repeated) |
An issue was observed in which the pendant did not work to control the crane. This is the second time in recent memory this has happened. See e-log 55 for details. The same sequence of steps outlined in e-log 55 was followed, and the pendant control was re-established. It is still unclear what the root cause of this issue is, but it is suspected that the crane pendant loses communication with the receiver for some reason, and even though communication can be re-established, the reset button on the crane control console does not clear the fault message, and the system must be power-cycled in order to fully reset. This is just speculation based on what is observed. Further investigation required. |
|
57
|
Friday, January 13, 2023, 13:57 |
Adam Newsome | T-Hall Crane | Repair | Crane light (west) not working |
It was observed today that the crane's west light was not functioning. |
|
56
|
Tuesday, December 20, 2022, 10:03 |
Adam Newsome | T-Hall Crane | Standard Operation | Overhead crane powered off for the holidays |
[edit 2023-01-03] The crane was powered back on this morning - there do not appear to be any faults on the HMI and it seems that the crane was unaffected by the power outage.
The ARIEL target hall overhead crane was powered off for the holidays. In the new year, throw the main disconnect in the crane control room to power back on. |
|
55
|
Wednesday, August 24, 2022, 13:47 |
Adam Newsome | T-Hall Crane | Standard Operation | Pendant/Receiver Communication Issue |
In preparing to troubleshoot the issue described in e-log #54, the crane was power cycled, and the pendant battery removed, to get to a "fresh start" state. Prior to this, the crane functioned normally aside from the incorrect E/W direction control on the North Aux Hoist.
Upon powering the crane back on, the pendant did not work to control the crane in any mode. The HMI had a fault present which read "305. Radio Control Receiver in Fault (3700RC)". This was accompanied by a red light in the safety control relay status summary screen, for "Radio Control Converter Communication Fault With Receiver (3714CONV)".
If the crane was placed in remote mode, the safety control relay status summary all turned green, and the reset button could be pressed, enabling remote mode. This means the issue was specific to the pendant/receiver communication specifically.
The receiver (in the cabinet in the control room) was inspected and the power status LED was on, the RF LED was off (which means there is no issue, OK), and the "OK to receive signal" LED was on - this indicates that the receiver was functioning as expected.
To further troubleshoot the issue - the crane was powered off, the receiver's antenna was disconnected and reconnected, and the multipin connector for the receiver was disconnected and reconnected. The system was powered back on, and the reset button was pressed. The fault message and the safety relay issue were cleared, and the pendant functioned again as normally expected (aside from the persistent issue from e-log #54).
It is unclear exactly what the issue was and how it was resolved, but could have been related to either a loose connector, or power cycling and resetting the system. |
|
54
|
Tuesday, August 23, 2022, 10:32 |
Adam Newsome | T-Hall Crane | Maintenance | North Aux Hoist - reverse motion axes on E/W |
Update 2022-10-06: During routine inspection of the crane, Tom Kauss investigated the direction swap issue. It was determined that there was likely an issue with the initial installation of the new VFD back in March 2022, and that it was unnoticed (directional control wires crossed). The issue has been resolved by Tom Kauss and is no longer a concern.
It was observed during operation today (Aug. 23, 2022) that the motion axes were reversed for East/West travel on the North Aux Hoist. i.e. when pressing the joystick on the local pendant in the East direction, the hoist traveled West, and vice-versa. This behaviour was not noticed (or at least not reported) before. It could potentially be related to the recent replacement which was done in March 2022 (https://elog.triumf.ca/TIS/RH-ARIEL/52), although the motion was checked after replacement. It is possible that an oversight was made in the testing at that time though.
The controls should be checked and the issue should be rectified as soon as possible. The Aux Hoist controls are not run through the PLC, but rather handled directly within the hoist's control box. It is recommended to go online with the PLC and check if there is any hint as to why this is occurring, before making any modifications. If no info can be gained, it is recommended to try swapping the VFDs for East and West motion, and check if that rectifies the issue. It is possible that the VFDs are programmed specifically for their direction output, and they simply need to be swapped.
|
|
53
|
Monday, May 30, 2022, 12:58 |
Adam Newsome | T-Hall Crane | Development | Reversion of South position limit to OEM value |
The position limit modification described in e-log 49 has been reverted. Currently the South soft limit is set back to 0.36m.
The limit was tested and confirmed (craned stopped at 0.33m position which is acceptable due to coasting). The entire bridge range of motion was checked to ensure there were no adverse effects - all is OK. The South bumpers need to be reinstalled - this will take place in the coming weeks.
Changes noted in crane log book.
Relevant work permit: A2022-05-30-3
Edit (2022-06-08): the bumpers have been re-installed. |