OLIS Logbook General
  General, Page 3 of 26  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  104   Fri Jul 17 10:32:42 2009 Damien Gallop  16O8+ recheckA/q = 2 Field = 667.3 FC6 = ~10enA  grab.X25481.png 
  105   Fri Jul 17 10:46:06 2009 Damien Gallop  16O6+ recheckA/q = 2.666 Field = 767.1G FC6 = 3enA  grab.C25591.pnggrab.q25595.pnggrab.Q25796.pnggrab.w25831.pnggrab.c25693.png 
  106   Fri Jul 17 11:10:21 2009 Damien Gallop  Supernanogan development doneBeam switched back to 18O4+ by 11:00 as
agreed. Some glitches. Here are snapshots
of how it looked at handover time.
 6x 
  107   Mon Jul 20 09:25:35 2009 Damien Gallop  18O4+ run to TIGRESS completeThe 18O4+ run at about 5MeV/u ended this
morning with reasonable success, I'm informed,
despite MCIS vacuum trips, SC cryo trips
 grab.rt5424.pnggrab.kH5418.pngPicture_25.pngPicture_24.pngPicture_23.png 
  108   Mon Jul 20 17:28:01 2009 Damien Gallop  MCIS cart removed from cage and parkedWe discussed whether or not to leave the
Supernanogan in the OLIS Faraday cage, and
decided no, because the up-coming runs will
  
  109   Tue Jul 21 17:11:33 2009 Damien Gallop  MWS preparations for 21Ne operationWith the MCIS cart removed, Geoff hooked
up the leak detector to the MWS source gas
line. He did a couple of hours of leak checking
 Picture_23.png 
  110   Wed Jul 22 01:33:29 2009 Damien Gallop  MWS initial startup summaryVacuum came down to ~7e-7 Torr. On startup,
bias sparked over somewhere. Vacuum leak
was caused. Later we found that HV had sparked
  
  111   Wed Jul 22 14:31:28 2009 Damien Gallop  21Ne setup to TUDA-II is underwayLast night Keerthi resolved the sparking
issue in MWS and started the source while
I was present. There was a frozen interlock
 Picture_27.pngPicture_24.png 
  112   Mon Jul 27 14:39:22 2009 Damien Gallop  21Ne5+ to TUDA-II21Ne has been available from the MWS since
mid-week. Here is roughly how last week unfolded
to now:
  
  113   Mon Aug 3 08:39:31 2009 Damien Gallop  MWS 21Ne -> 25Mg switchoverConveniently scheduled for BC Day, we are
preparing to switch over the MWS to sputter
operation with MG source material. Operations
 grab.f18355.pnggrab.n18345.png 
  114   Tue Aug 4 11:13:04 2009 Damien Gallop  MWS source tuning for 25Mg operationThe source stayed up overnight just fine,
with a little 25Mg beam on FC6. This morning
I did a few mass scans to get a fix on Mg
 6x 
  115   Wed Aug 5 11:29:51 2009 Damien Gallop  MWS operation overnight and 25Mg statusSo... there evidently was a power bump
overnight, because the stability power supply
was "disconnected" from the system.
 grab.G24908.pnggrab.h24912.pnggrab.T24916.pnggrab.W24925.pnggrab.x24953.png 
  116   Thu Aug 6 17:02:00 2009 Damien Gallop  MWS 25Mg tuning to TIGRESS in progressTuning has been on-going through the day.
Here are a couple of emittance scans taken
in-between heartbeats. The first is zoomed
 7x 
  117   Fri Aug 7 10:16:38 2009 Damien Gallop  MWS 25Mg emittance scansWhile there is an SC cavity issue, I have
been repeating last evening's emittance scans.
Here is the best one. About 70nA of 25Mg
 6x 
  118   Fri Aug 7 14:42:29 2009 Damien Gallop  MWS 25Mg beam reductionAround noon, Keerthi adjusted the PE down
to reduce the intensity of the Mg beam, as
we are running with attenuators in. He ended
 grab.jpa367.pnggrab.zFr371.pnggrab.PTd375.pnggrab.DYQ403.png 
  119   Mon Aug 10 16:12:28 2009 Damien Gallop  MWS 25Mg operation over the weekendSummary: good.
Details: A trip occurred at some
point. I restarted the source over the weekende
 grab.m23211.pnggrab.F23215.png 
  120   Mon Aug 10 16:36:33 2009 Damien Gallop  MWS 25Mg emittance scansA series of 25Mg emittance scans for Rick.
Starting scan with everything as-is,
i.e. slits closed.
 grab.d23286.pnggrab.w23291.pnggrab.U23295.pnggrab.U23312.pnggrab.q23316.png 
  121   Mon Aug 10 16:43:59 2009 Damien Gallop  MWS 25Mg emittance scan with slits openBefore proceeding, I nudged in each of
the slits, watching for first clipping. With
the current emittance (nice), the beam cleared
 grab.G23396.pnggrab.g23400.pnggrab.r23404.png 
  122   Mon Aug 10 17:16:20 2009 Damien Gallop  MWS 25Mg emittance scan with downstream quads offHere is the emittance scan that Rick requested,
beam with Q4/5/6 off. Note that present numbers
for these quads do not match theoretical.
 grab.E23496.pnggrab.o23517.pnggrab.J23522.pnggrab.Q23526.png 
  123   Mon Aug 10 17:20:55 2009 Damien Gallop  MWS 25Mg emittance scan with zeroed vertical steerersHere is a variation I thought might be
appropriate.
Data file: 090810_1724ILTEMIT.txt
 grab.k23573.pnggrab.m23577.pnggrab.v23582.pnggrab.U23599.png 
ELOG V2.9.2-2455