ID |
Date |
Author |
Type |
Category |
Subject |
|
|
149
|
Fri Oct 2 15:58:36 2009 |
Keerthi | | | 17O and Ne gases are now connected |
A 1e-5 atm.cc/sec of 17O leak and a 1e-6 atm.cc/sec of neon leak are connected to the source through center tube of the RF transfer antenna.
Ne valve is open for upcoming CSB test. 17O valve is closed. All optics are set to A/Q=5.5. RF, EL and HV are off for the weekend since no ISAC ops at night. |
|
|
150
|
Sun Oct 4 19:16:46 2009 |
Keerthi | | | OLIS status |
Supernanogan is ready with 22Ne+4 for upcoming CSB run. EL, HV and RF are on. The anlyzing magnet and the other optics are set for A/Q=5.5.
A 2nA of 22Ne+4 is sitting at the FC6. If require more current, increase the RF up to 25W or change the frequency to 13.256GHz. |
|
|
151
|
Tue Oct 6 15:22:43 2009 |
Damien Gallop | | | 22Ne4+ & 20Ne4+ operation |
Over the weekend, Keerthi had set up 22Ne4+ to FC6 for the purpose of developing a tune matched with a similar tune from the CSB. However, yesterday it turned out that the CSB could not generate a 22Ne beam sufficiently bright for tuning. So the project was scrapped. Keerthi then changed the source for 20Ne4+ operation, and handed it over to Marco yesterday. I think that is going well. Here is a trar plot of overnight beam. |
| Attachment 1: 20Ne4_on_FC6.png
|
 |
|
|
152
|
Tue Oct 6 15:28:31 2009 |
Keerthi | | | OLIS A/Q changed to 5 (20Ne+4) |
Changed OLIS A/Q to 5 (20Ne+4) to satisfy the CSB and ISAC development changes. 8nA is sitting at the FC6 |
|
|
153
|
Wed Oct 7 16:54:33 2009 |
Keerthi | | | |
Today Supernanogan vacuum found to be down in the morning. Restarted easily. |
|
|
154
|
Thu Oct 8 09:39:52 2009 |
Damien Gallop | | | CSB Development with MCIS |
Friedhelm and Marco have requested 20Ne2+ from the Supernanogan, and plan to bring up the same from the CSB today. I am beginning MCIS bias conditioning. Goal: 24kV, maybe 25. Last save: 091008_0933.snapiosfc6
Later... Conditioning completed to 26kV. Set up a 20Ne2+ tune. It's largely a manual operation. Q3 off in keeping with the failure that occurred during the Mg run a while back.
Still later...We had a PV1 trip somewhere around 11am. That set us back apiece. Finally, done. Hand over to Sophia around 13:30. Snap: 091008_1325.snapiosfc6
Two notes to mention:
1. We fitted ferrite bead cores to all of the CANbus cables inside the IOS rack, as well as a couple at the Philtek separator power supply. We did this sequentially, observing CANbus cards on unfitted cards trip while the others stayed up, each time there was a significant bias spark. Right now the IOS CANbus diagnostics panel is all green, something I have not seen for a while.
2. As noted above, MCIS:PV1 tripped during our setup. We didn't notice until bias trips became unusually frequent without provocation. We happen to have been running emittance scans at the time, and could not account for an increasingly worse triangular shape to the emittance plot. Now we will recognize that shape as an indicator of a vacuum condition. I will paste them below later.
|
| Attachment 1: MCIS_HV_Conditioning.png
|
 |
|
|
155
|
Fri Oct 9 16:33:45 2009 |
Keerthi | | | 33S development |
SO2 gas line is connected again. Leak hand valve is closed.
Intermediate section is pumping through source chamber.
CSB development is completed.
|
|
|
156
|
Sun Oct 11 13:16:39 2009 |
Keerthi | | | MCIS:TP3 was off |
MCIS TP3 foumd off by 1:00 pm. Restarted without a problem
Before TP3 is on MCIS:IG1 is 5.47e-8 Torr.
After MCIS:TP3 = 5.21e-8 Torr
|
|
|
157
|
Sun Oct 11 13:17:37 2009 |
Keerthi | | | Neon Leak closed |
Neon leak close for upcoming 33S development. |
|
|
158
|
Sun Oct 11 17:09:52 2009 |
Keerthi | | | Vacuum with IOS:IV7 |
IOS:IG4 reads 1.25 e-7 Torr and IOS:IG1 reads 9.8e-8 Torr with IOS:IV7 is open
IOS:IG4 reads 8.35 e-8 Torr and IOS:IG1 reads 7.49e-8 Torr with IOS:IV7 is closed |
|
|
159
|
Sun Oct 11 17:11:31 2009 |
Keerthi | | | MCIS turbo pumps power levels |
MCIS:TP1 = 12W
MCIS:TP2 = 11W |
|
|
160
|
Tue Oct 13 14:14:17 2009 |
Damien Gallop | | | MCIS setup for 33S5+ |
Keerthi has reinstalled the SO2 source gas bottle onto MCIS. Presently it is closed off to the source. We have restarted the plasma. Present goal: a good setup for 33S5+ with background levels (hopefully near zero) on FC6. Source pressure was 4.xe-8 Torr this morning, and has crept up to 5.0e-8 since we restarted the RF.
Later... We scaled a A/q=5.5 tune up to A/q=6.6 (33/5). Separator field = 1459.9G. Tuning in progress.
Later... First pass, shown below. Skimmers < 5uA. Snap: 091013_1651.snapiosfc6
Source switched off for the night. |
| Attachment 1: Picture_2.png
|
 |
| Attachment 2: Picture_3.png
|
 |
| Attachment 3: Picture_4.png
|
 |
| Attachment 4: Picture_5.png
|
 |
|
|
161
|
Wed Oct 14 09:52:09 2009 |
Damien Gallop | | | MCIS development with 33S5+ today |
The source is on. There is background beam on FC6 presently, less than yesterday. That's probably a good thing. Let it cook for a bit, then check the tune. Note: EL is off, as yesterday. |
| Attachment 1: Picture_6.png
|
 |
|
|
162
|
Wed Oct 14 12:06:46 2009 |
Damien Gallop | | | MCIS development with 33S5+ |
MCIS was running with background only. Prepare to open SO2 source gas...
MCIS:IG1 = 5.4e-8 Torr
TP1 = 13W
TP2 = 10W
Status: Leak valve closed, line valve open.
Bump leak valve carefully... but not carefully enough. Pressure bump, and back to 6e-8. I am using line valve as a needle valve. Pretty touchy, but it works.
IOSIOC whiteouts and other funny things... I will ask assistance from ICR.
MCIS:IG1:= 7.4e-8 Torr with line valve barely cracked.
Well, it turns out that ICR is having trouble with other ion gauges in apparently unrelated sections. Interesting. Meanwhile, MCIS:IG1 trippd off and EPICS will not allow a reset. MCISIOC looks white... restart it.
Later... Controls + ICR have rebooted PLC1IOC and PLC2IOC, and perhaps others. Anyway, stuff is working again. Beam is on to MCIS:FC1 and IOS:FC3.
Later... Still no beam visible on FC6. But IG1 has crept up to ~2e-7 Torr. Open cage and adjust down. It's just about the smallest increment I can make, but it's a big step down. Meanwhile, The readback for IOS:MB field went crazy for a moment. I have it on a Stripchart, below.
Later... Liftoff. We now have 200epA on FC6 at 13.10GHz. Let it sit for a bit. Other possible resonances at 13.17, 13.24, 13.27, 13.34GHz. |
| Attachment 1: grab.w30542.png
|
 |
|
|
163
|
Thu Oct 15 09:43:00 2009 |
Damien Gallop | | | MCIS development with 33S5+ |
Source started. 33S5+ beam on FC6 using gas flow determined yesterday. At first blush, it appears we need a slightly higher flow. But for now we will spend some time optimizing with what we have. We may open and adjust the flow later.
Later... This flow is okay for now. It requires a *really* fine control, which we do not have at present. 3enA with 10W of power. One source spark about a half hour ago. Mainly it knocked off the separator PS. Spill characteristics are slightly different also. |
| Attachment 1: Picture_3.png
|
 |
|
|
164
|
Thu Oct 15 21:06:10 2009 |
Keerthi | | | OLIS status |
33S development is completed. A 3nA of 33S+5 can be produced with 10W of RF power and 2.5mm aperture.
If more beam is needed apertures and the power must be increased. There are some consequences for doing this.
MCIS optics and RF are off for the night. |
|
|
165
|
Mon Oct 19 10:09:13 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 |
Switch on source for stats. Source lit up perfectly. Slight adjustment on RF frequency. |
| Attachment 1: Picture_5.png
|
 |
|
|
166
|
Tue Oct 20 09:25:29 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 overnight |
The source stayed up quietly overnight with about 4enA on FC6. Once in a while a little burp occurs, visible as small beam and vacuum spikes. I have tweaked the RF frequency up a little for better centre of range. |
|
|
167
|
Wed Oct 21 11:01:37 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 overnight cont'd |
I alsmost want to write, see yesterday's entry! Source ran quietly with no interruptions. FTR, the separator stability program is also percolating along nicely. It was taking hits from nearby EMI until I added a ferrite split core to its USB cable at the computer end. |
|
|
168
|
Thu Oct 22 15:54:24 2009 |
Damien Gallop | | | MCIS on with 33S5+ on FC6 overnight cont'd |
The Supernanogan was on overnight quietly. FC6 went in this morning. (Didn't check if fingers were involved.) I now notice a strange pulsing in our Stripchart. See what you think. Note: field and A/q max scales are orders of magnitude higher than real life.
Later...At around 14:00 I added ferrite cores to the field probe cable at the CANbus interface box. That clipped the high side of the pulses completely. If I play very carefully with the field range, I can get small artifact-looking pulses to appear since I installed them (see 17:16 chart). In the meantime, I found that, contrary to appearances, the field stability program was not really regulating. A remote reboot of the server cured it. |
| Attachment 1: pulse.png
|
 |
| Attachment 2: pulse-clip.png
|
 |
| Attachment 3: pulse-tweak.png
|
 |