  112   Thu Nov 3 06:19:50 2005 Doug PreddyQuench Recoveryrestart system
Last night at about 7:00 there was a large power bump that shut the 
compressor and water pump off. I came in this morning and am restarting the 
system.
  113   Thu Nov 3 09:27:16 2005 Doug PreddyQuench Recoverystarted flow to solenoid
started flow to solenoid in parallel cold return.
  114   Tue Nov 15 07:25:10 2005 Doug PreddyNormal Runningpower supply problem
Saturday November 12 the solenoid power supply ramped itself down to zero. 
It would not ramp up unless the ramp rate was set to 30 minutes. At this 
setting the power supply ramped up to the required current. It seems to 
ramp slower than the 30 minute rate. Klaus also looked at the problem. His 
suggestion is to exercise/clean the switches and pots.
  115   Mon Dec 12 09:24:29 2005 Doug PreddyQuench RecoverySolenoid Quench on power lead temp
The solenoid tripped on power lead temps at about 9:15. I am recovering it 
from it's all around mode into parallel cold return.
  116   Thu Dec 22 15:10:44 2005 Doug PreddyShut Downshut down system
shuttting down the system. isolated cold box by closing v135. preparing to 
pump out cold box.
  117   Tue May 23 08:44:28 2006 Doug PreddyStart UpStarted turbines
Solenoid and cold box were pumped out last Tuesday. Cold box roughing pump 
initially would not start. had to retighten all wires on the contactor in 
the Sulzer control panel (RP900).
Started compressor on Friday. ran purifier over the weekend.
Started flow in parallel warm return. Started flow to turbines.
Replacing dead monitor on other control computer.
  118   Thu May 25 07:34:18 2006 Doug PreddyStart Upswitched to parallel cold return
switched to parallel cold return
  119   Fri May 26 07:29:54 2006 Doug PreddyStart UpCV155 closed
CV155 closed.
Temps about 15K
  120   Fri May 26 08:45:38 2006 Doug PreddyStart UpChanged to series mode
Changed to series mode.
Liquid level building.
  121   Fri May 26 10:03:03 2006 Doug PreddyStart UpStarted flow to power leads
Started flow to power leads.
Liquid level 15%
  122   Fri May 26 14:34:24 2006 Doug PreddyStart UpReady to run
Solenoid is cold, liquid level is 35%, power leads cold and seem stable.
Added one bottle helium to buffer tank. Pressure is 7 psi..
  123   Tue May 30 14:36:41 2006 Doug PreddyNormal Runningpower leads warming
power leads warming. closed HIC 142, then re-opened. temps falling
  124   Tue Jun 13 10:54:27 2006 Doug PreddyQuench RecoveryCompressor tripped off
No indicator lights etc as to why the compressor tripped. The only  light 
was a cold box fault. I had to shut off the main breaker before the 
compressor would come back on.
Started cooling in parallel  cold return.
  129   Fri Jun 16 08:12:04 2006 Doug PreddyNormal RunningLI108 indicates high on EPICS screen
LI108 indicates high on EPICS screen (150%)  Controller shows ~64%
  130   Fri Jun 30 11:13:00 2006 Doug PreddyNormal RunningE-log is back up and running
I would have made an entry when it died, but-----
  131   Fri Jun 30 11:17:57 2006 Doug PreddyNormal RunningSolenoid recovered
Tuesday night. June 27, 2006, the solenoid quenched for no apparent 
reason. It was restarted Wednesday morning. The vacuum in the solenoid 
went away (up to 8 Torr). This was found to be a result of a leaking 
isolation valve between the solenoid and T2. T2 was vented, which caused 
the solenoid to slowly vet. When T2 was pumped out again, the solenoid 
vacuum recovered. This caused a delay in recovering the solenoid. As of 
Friday morning 7:15 the solenoid power supply was ramped up.
  132   Mon Jul 3 23:01:34 2006 Doug PreddyQuench Recoverypower lead warming/ripples caused quench
power lead warming/ripples caused quench at 18:45 today. Compressor stayed 
on, but flow to solenoid stopped.
I started flow to solenoid at 22:40.
  133   Thu Jul 6 15:00:15 2006 Doug PreddyNormal Runningtest
  134   Thu Jul 6 15:04:17 2006 Doug PreddyNormal Runningtest
test
Attachment 1: M9daily log070306.XLS
  135   Thu Jul 20 00:25:16 2006 Doug PreddyQuench RecoverySolenoid quenched @ 11:15
Solenoid Quenched on C1 temp. It went above 5K. Shut off compressor. 
Restarting system @ 12:15
ELOG V2.9.2-2455