  186  
 | 
Mon Mar  5 14:59:41 2007 | 
Doug Preddy | Maintenance | Password | On the weekend someone used this log to send 
spam messages. I have 
 
installed a password for the write privilege. | 
   | 
| 
  185  
 | 
Fri Jan 26 15:10:37 2007 | 
Doug Preddy | Maintenance | new control computer installed | I have installed a new control computer at 
the M9 solenoid control panel | 
   | 
| 
  184  
 | 
Tue Nov 28 10:32:04 2006 | 
Doug Preddy | Quench Recovery | recovering after looong power outage | The power has been out for about 24 hours. 
Recovering coldbox, solenoid and 
 
beamline vacuum.PLC is down for the vacuum | 
   | 
| 
  183  
 | 
Wed Nov 15 17:05:49 2006 | 
Willy Andersson | Quench Recovery | powerleads cold, energizing solenoid | Powerlead temperatures have bottomed out, 
energizing solenoid to 300 
 
amps, ramp rate 60. | 
   | 
| 
  182  
 | 
Wed Nov 15 13:56:00 2006 | 
Doug Preddy | Quench Recovery | switch to series mode |   | 
   | 
| 
  181  
 | 
Wed Nov 15 11:09:28 2006 | 
Doug Preddy | Quench Recovery | Compressor tripped off | Compressor tripped this morning at ~8:45. 
I restarted the compressor, but 
 
turbine 1 would not spin up. I let it warm | 
   | 
| 
  180  
 | 
Tue Nov  7 10:35:32 2006 | 
Doug Preddy | Normal Running | Maintenance day | I ramped down the solenoid power suplly and 
shut off flow to the power 
 
leads. I will allow them to warm up and (hopefully) | 
   | 
| 
  179  
 | 
Fri Nov  3 12:09:51 2006 | 
Doug Preddy | Normal Running | Fine tuning | The power lead temperatures have been climbing 
at a rate of ~ 0.02K very 8 
 
hours. The negative lead started to show | 
   | 
| 
  178  
 | 
Tue Oct 31 08:37:34 2006 | 
Doug Preddy | Quench Recovery | Energizing solenoid |   | 
   | 
| 
  177  
 | 
Tue Oct 31 05:36:14 2006 | 
Doug Preddy | Quench Recovery | switch to series mode |   | 
   | 
| 
  176  
 | 
Tue Oct 31 03:52:29 2006 | 
Doug Preddy | Quench Recovery | power lead quench at 2:30 this morning | Compressor still on. Starting flow to solenoid | 
   | 
| 
  175  
 | 
Thu Oct 26 14:14:57 2006 | 
Doug Preddy | Quench Recovery | power lead quench | solenoid tripped on power lead temp. I was 
here and caught it. System 
 
cooling. | 
   | 
| 
  174  
 | 
Thu Oct 26 11:45:22 2006 | 
Doug Preddy | Quench Recovery | Solenoid cold | power leads cold 50% liquid.
 
Turning on power supply | 
   | 
| 
  173  
 | 
Thu Oct 26 08:18:10 2006 | 
Doug Preddy | Quench Recovery | switched to series mode | Switched to series mode at about 7:45. | 
   | 
| 
  172  
 | 
Thu Oct 26 04:34:15 2006 | 
Willy Andersson | Quench Recovery | Still in // cold return mode. | Leaving system cooling in // cold return mode, 
cooldown rates still good. 
 
Had flow on to powerleads since re-starting | 
   | 
| 
  171  
 | 
Thu Oct 26 04:27:31 2006 | 
Willy Andersson | Quench Recovery | Powerlead overtemp | 02:30 this morning got page from operations.
 
Looked at system online, appears that there 
was a powerlead overtemp
 | 
   | 
| 
  170  
 | 
Sun Oct 15 07:09:41 2006 | 
Other | Normal Running | cryopump bcp2 trip | Donald Arseneau reporting
 
 
Not really solenoid realated, but FYI...
 | 
   | 
| 
  169  
 | 
Fri Oct 13 00:13:57 2006 | 
Experimentor | Quench Recovery | Energized solenoid. | Hi there,
 
 
This is Khashayar (experimenter). Lookin | 
   | 
| 
  168  
 | 
Thu Oct 12 19:54:10 2006 | 
Willy Andersson | Quench Recovery | Energized solenoid. | Switched to series mode about 6 hours ago. 
Cooling continued including 
 
power leads until LHe level at about 50% | 
   | 
| 
  167  
 | 
Thu Oct 12 11:53:04 2006 | 
Willy Andersson | Quench Recovery | Compressor trip, 09:50 this morning. | Main compressor tripped, refrigerator shutdown. 
Checked with experimentors 
 
and main control room, no indications of | 
   |