Entry  Mon Mar 5 14:59:41 2007, Doug Preddy, Maintenance, Password 
On the weekend someone used this log to send spam messages. I have 
installed a password for the write privilege. Please contact me at 6399 
for the password.
Entry  Fri Jan 26 15:10:37 2007, Doug Preddy, Maintenance, new control computer installed 
I have installed a new control computer at the M9 solenoid control panel
Entry  Tue Nov 28 10:32:04 2006, Doug Preddy, Quench Recovery, recovering after looong power outage 
The power has been out for about 24 hours. Recovering coldbox, solenoid and 
beamline vacuum.PLC is down for the vacuum system. Started compressor and 
am flowing warm helium through the soleniod to warm it up while the vacuum 
Entry  Wed Nov 15 17:05:49 2006, Willy Andersson, Quench Recovery, powerleads cold, energizing solenoid 
Powerlead temperatures have bottomed out, energizing solenoid to 300 
amps, ramp rate 60.
Entry  Wed Nov 15 13:56:00 2006, Doug Preddy, Quench Recovery, switch to series mode 
 
Entry  Wed Nov 15 11:09:28 2006, Doug Preddy, Quench Recovery, Compressor tripped off 
Compressor tripped this morning at ~8:45. I restarted the compressor, but 
turbine 1 would not spin up. I let it warm for an hour and it started. I 
started flow to the solenoind in parallel cold return.
Entry  Tue Nov 7 10:35:32 2006, Doug Preddy, Normal Running, Maintenance day 
I ramped down the solenoid power suplly and shut off flow to the power 
leads. I will allow them to warm up and (hopefully) recover the flow rates. 
I am also regenerating the M9BCP@ cryopump.
Entry  Fri Nov 3 12:09:51 2006, Doug Preddy, Normal Running, Fine tuning 
The power lead temperatures have been climbing at a rate of ~ 0.02K very 8 
hours. The negative lead started to show some rippling this morning. The 
positive flow had dropped from >250mm to 240mm. I cycled CV142 and the 
Entry  Tue Oct 31 08:37:34 2006, Doug Preddy, Quench Recovery, Energizing solenoid 
 
Entry  Tue Oct 31 05:36:14 2006, Doug Preddy, Quench Recovery, switch to series mode 
 
Entry  Tue Oct 31 03:52:29 2006, Doug Preddy, Quench Recovery, power lead quench at 2:30 this morning 
Compressor still on. Starting flow to solenoid
Entry  Thu Oct 26 14:14:57 2006, Doug Preddy, Quench Recovery, power lead quench 
solenoid tripped on power lead temp. I was here and caught it. System 
cooling.
Entry  Thu Oct 26 11:45:22 2006, Doug Preddy, Quench Recovery, Solenoid cold 
power leads cold 50% liquid.
Turning on power supply
Entry  Thu Oct 26 08:18:10 2006, Doug Preddy, Quench Recovery, switched to series mode 
Switched to series mode at about 7:45.
Entry  Thu Oct 26 04:34:15 2006, Willy Andersson, Quench Recovery, Still in // cold return mode. 
Leaving system cooling in // cold return mode, cooldown rates still good. 
Had flow on to powerleads since re-starting cooling flow to solenoid.
Either I (when I return to work later this morning) or Doug will do the 
Entry  Thu Oct 26 04:27:31 2006, Willy Andersson, Quench Recovery, Powerlead overtemp 
02:30 this morning got page from operations.
Looked at system online, appears that there was a powerlead overtemp
that caused the quench. Compressor still running. After arriving to 
Entry  Sun Oct 15 07:09:41 2006, Other, Normal Running, cryopump bcp2 trip 
Donald Arseneau reporting

Not really solenoid realated, but FYI...
Entry  Thu Oct 12 19:54:10 2006, Willy Andersson, Quench Recovery, Energized solenoid. 
Switched to series mode about 6 hours ago. Cooling continued including 
power leads until LHe level at about 50% and powerleads appeared stable.
    Reply  Fri Oct 13 00:13:57 2006, Experimentor, Quench Recovery, Energized solenoid. 
Hi there,

This is Khashayar (experimenter). Lookin at all different temperatures and 
Entry  Thu Oct 12 11:53:04 2006, Willy Andersson, Quench Recovery, Compressor trip, 09:50 this morning. 
Main compressor tripped, refrigerator shutdown. Checked with experimentors 
and main control room, no indications of power bump etc.
Entry  Thu Oct 5 14:53:54 2006, Doug Preddy, Start Up, Switched to series mode 
 