ID |
Date |
Author |
Operational Mode |
Subject |
Text |
|
66
|
Sat Oct 16 17:18:50 2004 |
Other | | lame | |
|
65
|
Sat Oct 16 17:13:19 2004 |
Other | | s | s |
|
64
|
Wed Oct 13 08:17:00 2004 |
Experimentor | Start Up | cycling 142 when temp hit 10.68 | I tried cycling the valve twice -- at about
11:30 and again around 1:00,
trying both the buttons and the dial -- but |
|
63
|
Tue Oct 12 13:00:08 2004 |
Curtis Ballard | Start Up | cv142 valve | Curtis closes and opens slowly at about 11:00
am this morning. Wants to see
if that works better than the sudden on/off |
|
62
|
Tue Oct 12 02:05:31 2004 |
Experimentor | Start Up | cv142 valve | after only two hours since last lead cycling,
they warm up quickly.
ops cycles the valve, but more quickly this |
|
61
|
Mon Oct 11 22:32:11 2004 |
Experimentor | Start Up | cv142 valve | temp of leads begins its exponential rise
again (caught it at 12K), approx
11 hours after last reset. this time asked |
|
60
|
Mon Oct 11 11:49:34 2004 |
Experimentor | Start Up | cv142 valve | noticed temp rise, which occured only about
5 hours after the
last "reset" .... the time between resets |
|
59
|
Mon Oct 11 03:56:14 2004 |
Experimentor | Start Up | cv142 valve | noticed that the lead temp rose to 24K over
the past 4 hours. had control
room personnle cycle the cv142 valve. temperature |
|
58
|
Sun Oct 10 17:36:35 2004 |
Experimentor | Start Up | power leads | At 5:30 pm sundat, power lead temp is about
10.6K. script tool still
notworking
|
|
57
|
Sat Oct 9 22:50:26 2004 |
Other | | power leads warmed | At 10:30 PM Saturday, Donald Arseneau sees
power leads at
25K, having gone up for the previous 10 hours. |
|
56
|
Thu Oct 7 13:33:20 2004 |
Doug Preddy | Start Up | turned off purifier | turned off purifier |
|
55
|
Wed Oct 6 09:25:54 2004 |
Doug Preddy | Start Up | switch to series mode | switched to series mode |
|
54
|
Wed Oct 6 07:57:01 2004 |
Doug Preddy | Start Up | parallel cold return | Switched to parallel cold return at 4:00 yesterday
afternoon.
6:30 this morning started closing cv155 as |
|
53
|
Tue Oct 5 07:18:16 2004 |
Doug Preddy | Start Up | adjust compressor discharge pressure | adjusted compressor discharge pressure to
11 Bar |
|
52
|
Mon Oct 4 09:16:29 2004 |
Doug Preddy | Start Up | Started turbines | Started flow to the turbimes with the solenoid
in parallel warm return. |
|
51
|
Fri Oct 1 11:39:55 2004 |
Doug Preddy | Maintenance | Loading of compressor not working | When the compressor was restarted on Monday,
the remote load button would
not respond. The compressor was shut off. |
|
50
|
Mon Sep 13 13:56:06 2004 |
Doug Preddy | Shut Down | compressor off | compressor off |
|
49
|
Mon Sep 13 10:55:25 2004 |
Doug Preddy | Shut Down | Quench and shutdown | The solenoid quenched on powerlead temps this
morning at 10:00. It is
warming up and the power leads are >200K.Isolating |
|
48
|
Fri Sep 3 01:28:43 2004 |
Doug Preddy | Quench Recovery | power up | started flow to the power leads at 11:30.
Cold and stable at 1:00am.
Energized solenoid at 1:30. |
|
47
|
Thu Sep 2 21:58:34 2004 |
Willy Andersson | Quench Recovery | Switch to series cooling | Solenoid had tripped on powerlead overtemp
at about 09:00 this morning.
Doug recovered the system to // cooling. |
|